KITCO Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

KITCO Limited - KITCO Tender

Works
Coronavirus COVID 19
Eprocure
Opening Date4 Feb 2020
Closing Date20 Feb 2020
Tender Amount₹ 4,50,12,430 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od235284/2019_2020 : Supplying, filling, spreading , leveling of proposed yard with 40 mm size blue jelly of 150 mm thick including cost and conveyance of all materials, labour charges etc. complete.

10.8

-

-

... More
od235288/2019_2020 : HT Meteing Kiosk Design, supply, installation, testing and commissioning of Outdoor (IP54) Bidirectional TOD Metering kiosk and test terminal block, control fuses,armoured copper cable between CTPT unit and TOD meter, totally enclosed, free standing, floor mounting, dust , vermin proof cubicle type, made of 14SWG sheet steel powder coated with necessary cable alley , busbar chamber. The panel shall be with 630A aluminium PVC sleeved busbar , support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control etc, seal off bushings, control wiring with glass window for meter reading , locking facility etc.The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof,undergone seven tank process,powder coated finish ,earthing,entire civil work including suitable foundation and all mounting accessories as required complete as per the requirement of K.S.E.B

1

-

-

... More
od235294/2019_2020 : 11kV Outdoor RMU panel (Extensible Type) Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos motorized Load Break Switch as incomer and 2 nos motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators, Hooter ,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type and compatible for SCADA system .The rate quoted shall be inclusive of hoisting to its location,assembling of units, lining up, bolting the units and checking all control wiring complete as per single line diagram, technical specification.

1

-

-

... More
od235308/2019_2020 : 11kV Outdoor RMU panel (Extensible Type ccv) Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos motorized Load Break Switch as incomer and 1 no motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators, Hooter, battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type and compatible for SCADA system .The rate quoted shall be inclusive of hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram, technical specification.

1

-

-

... More
od235315/2019_2020 : UNITIZED SUBSTATION- 400KVA Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation including foundation for 400 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping , indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram , technical specification. HT Chamber 630A 25kA 11kV LBS with earth switch Transformer Compartment 400kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -5% in steps of 2.5%. The transformer shall also have suitable enclosure including supply and fixing of neutral CT of 120/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: 630 A MCCB Suitable for terminating 2 RUN x400 sq.mm cable.

1

-

-

... More
od235320/2019_2020 : UNITIZED SUBSTATION- 250KVA Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation including foundation for 250 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping , indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram , technical specification. HT Chamber 630A 25kA 11kV LBS with earth switch Transformer Compartment 250kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -5% in steps of 2.5%. The transformer shall also have suitable enclosure including supply and fixing of neutral CT of 80/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: 400 A MCCB and kWhmeter with provision Suitable for terminating 2 RUN x240 sq.mm cable. ,

1

-

-

... More
od235325/2019_2020 : UNITIZED SUBSTATION- 200KVA Design, fabrication,Supply, installation, testing and commissioning of indoor type Unitized Substation including foundation for 200 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping , indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram , technical specification. HT Chamber 630A 25kA 11kV LBS with earth switch Transformer Compartment 200kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -5% in steps of 2.5%. The transformer shall also have suitable enclosure including supply and fixing of neutral CT of 60/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: 320 A MCCB and kWhmeter with provision Suitable for terminating 2 RUN x185 sq.mm cable.

1

-

-

... More
od235330/2019_2020 : 100 kVA DIESEL GENERATOR ,Supply, Installation, Testing and Commissioning of 100 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 100 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 , IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inculsive of all the civil work like RCC foundation The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
od235334/2019_2020 : 82.5 kVA DIESEL GENERATOR ,Supply, Installation, Testing and Commissioning of 82.5kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 82.5 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 , IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inculsive of all the civil work like RCC foundation. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

2

-

-

... More
od235337/2019_2020 : 125 kVA DIESEL GENERATOR ,Supply, Installation, Testing and Commissioning of 125 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 125 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 , IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be inculsive of all the civil work like RCC foundation. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery. ,

1

-

-

... More
PANEL BOARD AND ACCESSORIES

-

-

-

... More
od235278/2019_2020 : MAIN SWITCH BOARD Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification.The panel shall have space provision for incorporating CO2 flooding system as per NBC standards. Incomer 630A FP Microprocessor based Moulded Case Circuit Breaker Busbar 630A TPN AL BUSBAR Instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . Low set earth fault protection relay with CT on the neutral of the transformer-1no Outgoings ,Surge Protection Devices for Main Panel: Class B , Class C- 1 set The panel should include Pluggable type surge arrester Class B , Class C/ Class 1 , Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap , 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element , pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) , 60KA (8/20µ sec) for Line to Neutral , 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) , <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec , 3 phase 4 wire CT operated type, 415V, 5-10 A flush mounted electronic type energy meter class1(as per K.S.E.B standards) -As per SLD 400A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos. 250 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 3nos. 200 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos.

1

-

-

... More
od235285/2019_2020 : BH-DG PANEL Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 250 A FP Microprocessor based Moulded Case Circuit Breaker Busbar 250A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . Outgoings 200 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos. 125 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 2nos. 3 phase 4 wire CT operated type, 415V, 5-10 A flush mounted electronic type energy meter class1(as per K.S.E.B standards) -As per SLD

1

-

-

... More
od235295/2019_2020 : BH-MSB Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification.The panel shall have space provision for incorporating CO2 flooding system as per NBC standards. Incomer 250A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-1 nos Busbar 250A TPN AL BUSBAR Meters and instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . Outgoings Surge Protection Devices Surge Protection Devices for Main Panel:Class B , Class C- 1 set The panel should include Pluggable type surge arrester Class B , Class C/ Class 1 , Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap , 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element , pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) , 60KA (8/20µ sec) for Line to Neutral , 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) , <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Outgoings 125A, 25kA, TP+NL, MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 5nos

1

-

-

... More
od235310/2019_2020 : 120 kVAR APFC PANEL ,Supply, Installation, Testing and Commissioning of totally enclosed, free standing, floor mounting, dust and vermin proof,form 3 b construction, cubicle type capacitor panel board of total 120 KVAR capacity to be fabricated out of 2mm thick CRCA sheet steel Powder coated with provision for capacitor mounted inside the panel with adequate number of louvers, internal wiring with suitavle wires and powder coated with approved shade and having following components as per SLD and Technical specification , The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per SLD and technical specification Incomer ,250A, FP, 25kA, MCCB with Thermal based release with OL , SC protection - 1 Nos , Instruments 4A C curve SP MCB,4 A HRC Fuse with base , Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs , IPFC Relay as per SLD . Busbar 250A TPN busbar chamber with Aluminium busbar. Outgoing 125A, 25kA, TP MCCB with adjustable thermal magnetic release with OL , SC protection - 1nos. 63A, 25kA, TP MCCB with adjustable thermal magnetic release with OL , SC protection - 5nos. 50 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1No. 30kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1 No. 20 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1 No. 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 No. 50 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1 Nos 30 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1No 20 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1No 10 kVAr,480 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2No Control wiring required for no load compensation capacitor

1

-

-

... More
od235316/2019_2020 : TQ-MSB Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification.The panel shall have space provision for incorporating CO2 flooding system as per NBC standards. Incomer 320A FP Microprocessor based Moulded Case Circuit Breaker Busbar 320 A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . 3 phase 4 wire CT operated type, 415V, 5-10 A flush mounted electronic type energy meter class1(as per K.S.E.B standards) -As per SLD. Outgoings Surge Protection Devices Surge Protection Devices for Main Panel:Class B , Class C- 1 set The panel should include Pluggable type surge arrester Class B , Class C/ Class 1 , Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap , 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element , pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) , 60KA (8/20µ sec) for Line to Neutral , 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) , <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Outgoings 160A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 3nos. 125 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos. The panel should have space provision for locating 2 st of 63 A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA)

1

-

-

... More
od235326/2019_2020 : NTQ-MSB Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification.The panel shall have space provision for incorporating CO2 flooding system as per NBC standards Incomer 400A FP Microprocessor based Moulded Case Circuit Breaker Busbar 400 TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . 3 phase 4 wire CT operated type, 415V, 5-10 A flush mounted electronic type energy meter class1(as per K.S.E.B standards) -As per SLD. Surge Protection Devices Surge Protection Devices for Main Panel:Class B , Class C- 1 set The panel should include Pluggable type surge arrester Class B , Class C/ Class 1 , Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap , 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element , pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) , 60KA (8/20µ sec) for Line to Neutral , 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) , <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Outgoings 125A 25 kA TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 6 nos. 160A 25 kA TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1 nos. 63 A 25 kATP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos.

1

-

-

... More
od235346/2019_2020 : GH-Common Panel Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 160A A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-1nos 125A A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-1nos Busbar 160A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays,ATS with AMF relay as per SLD . Outgoings 100A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-1nos 63A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-2nos 63A FP MCB ISOLATOR-3nos

1

-

-

... More
od235347/2019_2020 : GH-MSB Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification. The panel shall have space provision for incorporating CO2 flooding system as per NBC standards. Incomer 400 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-1 nos Busbar 400A TPN AL BUSBAR Meters and instruments 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . Outgoings Surge Protection Devices Surge Protection Devices for Main Panel:Class B , Class C- 1 set The panel should include Pluggable type surge arrester Class B , Class C/ Class 1 , Class 2 as per IEC 61643 (IP 20) with inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap , 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element , pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) , 60KA (8/20µ sec) for Line to Neutral , 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) , <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec Outgoings 160A, 25kA, TP+NL, MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1nos 125A, 25kA, TP+NL, MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 3nos 100A, 25kA, TP+NL, MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1nos

1

-

-

... More
od235354/2019_2020 : BH-COMMON PANEL Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 125A A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-2nos Busbar 125A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays,ATS with AMF relay as per SLD . Outgoings 63A TP+NLMoulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-4nos 63A FP MCB Isolator-3nos 40A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-1nos

1

-

-

... More
od235355/2019_2020 : NTQ-Common Panel Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 160A A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-2nos Busbar 160 A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays,ATS with AMF relay as per SLD . Outgoings 63A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-2 nos 40A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-3 nos 63A FP MCB ISOLATOR-3nos

1

-

-

... More
od235360/2019_2020 : TQ-Common Panel Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 125A A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 36KA).-2nos Busbar 125A TPN AL BUSBAR Meters 4A, C curve SP MCB, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays,ATS with AMF relay as per SLD . Outgoings 63A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-2nos 40A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 16KA).-3nos 63A FP MCB ISOLATOR-3nos

1

-

-

... More
od235361/2019_2020 : Teaching Quarters-Metering Panel -1,2,3 TYPICAL Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 160A, 25kA, FP MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1 no. Busbar 100A TPN AL BUSBAR Outgoings 3 phase , 415V- flush mounted electronic type energy meter class1(as per K.S.E.B standards) - 8No. 40A HRC fuse with fuse link - 24 nos Neutral link - 8 nos 40A TPN/ 16 A SPN ACCL - (set at 0.5 kw for single phase load)-8 nos 40A, FP MCB isolator - 8nos

3

-

-

... More
od235364/2019_2020 : NTQ-Metering Panel- 1 Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 125A, 25kA, FP MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1 no. Busbar 125A TPN AL BUSBAR Outgoings 3 phase , 415V- flush mounted electronic type energy meter class1(as per K.S.E.B standards) - 5No. 40A HRC fuse with fuse link - 15 nos Neutral link - 5 nos 40A TPN/ 16 A SPN ACCL - 4 Nos (set at 0.5 kw for single phase load)-5 nos 40A, FP MCB isolator - 5 nos All outgoing feeders should have glass window for meter reading and locking facility for KSEB Space provision for 3 sets of 40A metered outlets with HRC fuse, neutral link cutout and energy meter with glass window for meter reading , locking facility and ACCL

1

-

-

... More
od235366/2019_2020 : Non Teaching Quarters-Metering Panel - ( 2, 3, 4, 5)Typical Supply, Installation, Testing , Commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed,form 4b type construction, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , specification Incomer 125A, 25kA, FP MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1 no. Busbar 125A TPN AL BUSBAR Outgoings 3 phase , 415V- flush mounted electronic type energy meter class1(as per K.S.E.B standards) - 8 No. 40A HRC fuse with fuse link - 24 nos 40A TPN/ 16 A SPN ACCL - 8 Nos (set at 0.5 kw for single phase load)-8 nos Neutral link - 8 nos 40A, FP MCB isolator - 8 nos All outgoing feeders should have glass window for meter reading and locking facility for KSEB

4

-

-

... More
od235371/2019_2020 : PUMP PANEL-1 Supply, Installation, Testing and Commissioning of LT Switch board cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP42, form 4b constructon, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing , technical specification. Incomers ,200A, FP, 25kA, MCCB with Thermal based release with OL , SC protection - 1 Nos , ,200A, ATS with AMF Realy- 1 nos , Instruments 4A C curve SP MCB, 4A HRC Fuse with base, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . Busbar 200A TPN AL BUSBAR Out goings 25A Motor protection circuit breaker with overload and short circuit protection for 5.2kw motor-4nos 40A Motor protection circuit breaker with overload and short circuit protection for 11 kw and 7.5 kw motor-9 nos 63A Motor protection circuit breaker with overload and short circuit protection for 2 kw motor-1 nos 3 phase DOL starter with on/off push button,thermal overload relay, single phasing preventer and auxillary ,power contactors for 1 kw motor - 1 nos. 3 phase FASD starter with on/off push button,thermal overload relay, single phasing preventer and auxillary ,power contactors for 11kw motor - 6 nos. 3 phase FASD starter with on/off push button,thermal overload relay, single phasing preventer and auxillary ,power contactors for 7.5 kw motor - 2 nos. 3 phase FASD starter with on/off push button,thermal overload relay, single phasing preventer and auxillary ,power contactors for5.2 kw motor - 2 nos. Space provision for fixing 3 phase DOL /star-delta starter with on/off push button, thermal overload relay, single phasing preventer and auxillary , power contactors , ON/OFF indication lamps,capacitors in spare outlets -2 nos

1

-

-

... More
od235377/2019_2020 : Outdoor Lighting Panel (ODP) Supply, Installation, Testing and Commissioning of Outdoor Lighting Panel (ODP) cubicle type, totally enclosed, IP 65, pedestal mounted, free standing with top canopy, dust and vermin proof, water proof suitable for operation on 3 phase, 415 V, 50Hz AC supply with provision for fixing incoming , outgoing switches fabricated using 2mm thick CRCA sheet, powder coated, including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc., The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) including following switchgears accessories for the LT Panel. All necessary mounting accessories as required complete with civil foundation.The panel shall be with all accessories as per drawing , specification. INCOMER ,32A, FP, 25kA, MCCB with Thermal based release with OL , SC protection - 1 Nos , BUSBARS 32 A TPN AL BUBAR INSTRUMENTS 4A C curve SP MCB,, Ammeters, Voltmeters, Selector Switches,Multifunction Meters Indication Lamps, CTs, Protection Relays as per SLD . 25A, FP, AC1 contactor with auxiliary contacts - 1 nos. 24 hrs Digital Timer with inbuilt battery - 1 no. Type 1+2 surge protection device- 1 nos OUTGOINGS 16A 100mA FP (RCCB+MCB) -(1+2) nos. 25A 100mA FP (RCCB+MCB) -5 nos.

1

-

-

... More
od235380/2019_2020 : UPS AND ACCESSORIES Supply , Installation, Testing and Commissioning of 1 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage , frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation

4

-

-

... More
CABLE AND CABLING

-

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

705

-

-

... More
od235273/2019_2020 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required. 3C x 300 sq.mm.

36

-

-

... More
od235276/2019_2020 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300 sq.mm.

946

-

-

... More
8.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm

10

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

50

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

2

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

8

-

-

... More
od235304/2019_2020 : Providing, laying and fixing following dia RCC pipe NP4 class HEAVY duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (1.2 m deep) and refilling etc as required. 300 mm dia

50

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

31

-

-

... More
od235311/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 400 Sq.mm Al

88

-

-

... More
od235317/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 240 Sq.mm Al

319

-

-

... More
od235321/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 120 Sq.mm Al

396

-

-

... More
od235327/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 185 Sq.mm Al

132

-

-

... More
od235331/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 95 Sq.mm Al

10

-

-

... More
od235335/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 70 Sq.mm Al

99

-

-

... More
od235338/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3.5C 50 Sq.mm Al

10

-

-

... More
od235341/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 35 Sq.mm Al

132

-

-

... More
od235342/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 25 Sq.mm Al

10

-

-

... More
od235344/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 16 Sq.mm Al

5618

-

-

... More
od235349/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 10 Sq.mm Al

10

-

-

... More
od235350/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 6 sqmm Al

1463

-

-

... More
od235353/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 4 sqmm Al

1375

-

-

... More
od235357/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 4C 2.5 sqmm Cu

308

-

-

... More
od235359/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 16sqmm Al

677

-

-

... More
od235362/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 10 sqmm Al

198

-

-

... More
od235363/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 6sqmm Al

110

-

-

... More
od235365/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 4sqmm Al

17

-

-

... More
od235369/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date 3C 2.5 sqmm Cu

50

-

-

... More
od235370/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 10 sqmm Al

1647

-

-

... More
od235375/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date. 12C 2.5 sqmm Cu

50

-

-

... More
od235378/2019_2020 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper FRLS conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 1.5 sqmm Cu

40

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

68

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

10

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

8

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

12

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

12

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

20

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

6

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

36

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

6

-

-

... More
od235421/2019_2020 : Supply , making cable end termination for 4Cx6.sqmm XLPE insulated Aluminium conductor cable.

86

-

-

... More
od235422/2019_2020 : Supply , making cable end termination for 3Cx6 sqmm XLPE insulated Aluminium conductor cable.

8

-

-

... More
od235423/2019_2020 : Supply , making cable end termination for 3CX2.5.sqmm XLPE insulated Aluminium conductor cable.

2

-

-

... More
od235424/2019_2020 : Supply , making cable end termination for 4Cx4.sqmm XLPE insulated Aluminium conductor cable.

110

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

194

-

-

... More
od235425/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 4C 2.5 sqmm Cu

20

-

-

... More
od235426/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3C 4sqmm Al

2

-

-

... More
od235427/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12C 2.5 sqmmCu

10

-

-

... More
od235428/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2C 1.5 sqmm Cu

16

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

1280

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

30

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

161

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

176

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

1300

-

-

... More
7.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

66

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

165

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

200

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

45

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

29

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

5

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

5

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

23

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

5

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

4291

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

34

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

161

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

15

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

4474

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

35

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

127

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

22

-

-

... More
od235429/2019_2020 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 40mm

5

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

10

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

45

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

140

-

-

... More
od235430/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 600 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od235431/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 450 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od235432/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 300 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od235433/2019_2020 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 150 MM WIDTH X 50 MM DEPTH X 2 MM THICK

20

-

-

... More
od235434/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts , nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

730

-

-

... More
od235435/2019_2020 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts , nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

520

-

-

... More
od235436/2019_2020 : Providing , fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke , Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

0.6

-

-

... More
od235437/2019_2020 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

530

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

40

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

142

-

-

... More
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

955

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

1323

-

-

... More
od235286/2019_2020 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable with modular switch, modular plate, and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required in existing surface / recessed medium class PVC conduit and suitable GI box. Group A (3 meter)

142

-

-

... More
od235290/2019_2020 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable with modular switch, modular plate,and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required in existing surface / recessed medium class PVC conduit, suitable GI box . Group B (4 meter)

955

-

-

... More
od235296/2019_2020 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required in existing in surface / recessed medium class PVC conduit and suitable GI box .(Note:The total distance from the switch box to the point will not exceed 5mtr, incase if length increases above 5 metres, the wiring shall be measured under item 7.09.01) Group C

878

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

70

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

313

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

12928

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

21380

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

4720

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

1292.8

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

2138

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

472

-

-

... More
od235336/2019_2020 : Supplying and fixing following modular switch/ socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. 6 pin 15/16 amp socket outlet

211

-

-

... More
od235340/2019_2020 : Supplying and fixing following modular switch/ socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. 15/16 amp switch

211

-

-

... More
od235343/2019_2020 : Supplying and fixing following modular switch/ socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. Bell push

63

-

-

... More
od235345/2019_2020 : Supplying and fixing following modular switch/ socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. Telephone socket

67

-

-

... More
od235348/2019_2020 : Supplying and fixing following modular switch/ socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. TV antenna socket outlet

65

-

-

... More
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair

4575

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

600

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

800

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

900

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

1734

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

216

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

63

-

-

... More
od235384/2019_2020 : Supplying and fixing stepped type electronic fan regulator with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete.

1097

-

-

... More
od235386/2019_2020 : Supply , fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

40

-

-

... More
od235388/2019_2020 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate , cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

40

-

-

... More
od235390/2019_2020 : Making chases up to 7.5x7.5 cm in walls including making good andfinishing with matching surface after housing G.I. pipe etc

120

-

-

... More
od235393/2019_2020 : Supply and fixing following size / Module GI box in surface/ recess etc . As required 1 or 2 module Module

55

-

-

... More
od235395/2019_2020 : Supply and fixing following size / Module GI box in surface/ recess etc . As required 3 Module

55

-

-

... More
od235399/2019_2020 : Supply and fixing following size / Module GI box in surface/ recess etc . As required 4 Module

55

-

-

... More
od235401/2019_2020 : Supply and fixing following size / Module GI box in surface/ recess etc . As required 6 Module

55

-

-

... More
od235402/2019_2020 : Supply and fixing following size / Module GI box in surface/ recess etc . As required 8 Module

55

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

80

-

-

... More
od235298/2019_2020 : Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 125/160 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 Way 8 Way

6

-

-

... More
od235312/2019_2020 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125Amp,25KA,FPMCC

6

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1396

-

-

... More
od235352/2019_2020 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 63A ,FP MCB

5

-

-

... More
od235358/2019_2020 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40A TP MCB,

56

-

-

... More
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

9

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

27

-

-

... More
od235381/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25 amps. (230 Volts),30mA sensitivity.

32

-

-

... More
od235382/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25amps. (415 Volts), 100mA sensitivity

2

-

-

... More
od235383/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 25 amps. (415 Volts), 30mA sensitivity.

32

-

-

... More
od235387/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 40 amps. (415 Volts),30mA sensitivity.

91

-

-

... More
od235389/2019_2020 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 40 amps. (415 Volts),100mA sensitivity.

6

-

-

... More
od235394/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required • 8 way (8 + 24), Double door

3

-

-

... More
od235397/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required • 6 way (8 + 18), Double door

86

-

-

... More
od235403/2019_2020 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (8 + 12), Double door

3

-

-

... More
od235405/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 6 way (4 + 18), Double door

5

-

-

... More
od235406/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door

1

-

-

... More
od235407/2019_2020 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB s (but without MCB s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door

5

-

-

... More
od235408/2019_2020 : Supply, Installation, Testing , Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. Make: Enclosure- Siemens 8GB32100RC0X or equivalent approved make

12

-

-

... More
od235409/2019_2020 : Supply , Installation, testing and commissioning of 125A Automatic Transfer switch in enclosure with all necessary accessories as required complete with mounting arrangement. ( Make : ASCO or equivalent approved make )

1

-

-

... More
od235410/2019_2020 : Supply , Installation, testing and commissioning of 200A Automatic Transfer switch in enclosure with all necessary accessories as required complete with mounting arrangement. ( Make : ASCO or equivalent approved make )

1

-

-

... More
od235411/2019_2020 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

10

-

-

... More
od235412/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way vertical TPN DB (MCCB incomer)

6

-

-

... More
od235413/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way vertical TPN DB (MCB incomer)

1

-

-

... More
od235414/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 4 way vertical TPN DB (MCB incomer)

5

-

-

... More
od235415/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way double door horizontal type TPN DB

2

-

-

... More
od235416/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 6 way double door horizontal type TPN DB

84

-

-

... More
od235417/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 4 way double door horizontal type TPN DB

4

-

-

... More
od235418/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 6 way double door horizontal type SPN DB

9

-

-

... More
od235419/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 8 way double door horizontal type SPN DB

1

-

-

... More
od235420/2019_2020 : Supply and fixing of following way IP 43 rated cable end box with all accessories as required compete for suitable DB Cable end box for 12 way double door horizontal type SPN DB

27

-

-

... More
od236564/2019_2020 : Supply, Installation, Testing , Commissioning of 32A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete. Make: Enclosure- Siemens 8GB32100RC0X or equivalent approved make

8

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

486

-

-

... More
od235270/2019_2020 : Supply of following sizes of 900 mm sweep. ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 230 V/240 V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make: Orient New Breeze or other approved equivalent make).

61

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
od235277/2019_2020 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1500, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 80lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Philips BN021C LED20S PSU NW GR or Wipro LL20-221-XXX-60-XX or Crompton Greaves DMLN1LT16+LT16 or equivalent approved make

1998

-

-

... More
od235281/2019_2020 : Supply of surface mounted LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating, along with driver,system wattage of 36 +/- 3Watts with lumen output of lamp not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No:Wipro:Immaculated LED or equivalent one)

35

-

-

... More
od235291/2019_2020 : Supply of IP65 streetlight luminar made of die cast aluminium along with driver,system wattage of 30+/-2 Watts,lumen output of lamp greater than 3000 lumens, power factor 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 95 lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX , crompton other approved equivalent makes)

34

-

-

... More
od235299/2019_2020 : Supply of recess mounted LED panel light fixture light made of die cast aluminium with corrosion resistance p[owder coating, along with driver,system wattage of 36 +/- 2 Watts with lumen output of lamp not less than 3600 lumens, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No:Wipro:Immaculated LED DD , crompton or equivalent one)

17

-

-

... More
od235302/2019_2020 : Supply of indoor industrial surface mounted LED tube with Batten along with driver, surge protector, system wattage of 38+/-2 lumen output of lamp greater than 3000 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 90lumen/watt and including all necessary accessories as required complete.. (Make Crompton LPFC-36-CDL or other approved equivalent makes)

91

-

-

... More
od235307/2019_2020 : Supply of IP65 industrial luminaire made of polycarbonate housing along with driver,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1800 lumens, power factor 0.9, rated life of L70 @ 50,000 hours system efficacy greater than 90 lumen/watt ,with suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Crompton -LPFC -18-CDL or other approved equivalent makes)

6

-

-

... More
od235309/2019_2020 : Supply of decorative wall light LED along with driver,system wattage maximum of 12(+/-2W) Watts,lumen output of lamp greater than 800 lumens, power factor0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 80lumen/watts,with suitable driver and including all necessary accessories as required complete.Make:- Cat No: Klite WALL DENNA SLIMMY or equivalent approved make)

224

-

-

... More
od235333/2019_2020 : Supply of indoor decorative surface mounted LED Batten with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of lamp greater than 800, power factor 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Wipro LL20-121-XXX-60-XX or Crompton Greaves DMLN1LT16+LT8 or equivalent approved make

561

-

-

... More
od235339/2019_2020 : Supply of indoor industrial surface mounted LED tube with Batten along with driver, surge protector,system wattage of 40+/-4 Watts(2x20 watts),lumen output of lamp greater than 3000 lumen, power factor 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro WIO922208 + 2 Nos. of 18W LED Tube Light or Crompton Greaves IGP132LT8-16+LT8-20

55

-

-

... More
od235351/2019_2020 : Installation, testing and commissioning of pre - wired,LED/ fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

2746

-

-

... More
od235372/2019_2020 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)

482

-

-

... More
od235373/2019_2020 : Supply of 380 mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton EXHD-380-6-1, ALMONARD or equivalant approved make)

4

-

-

... More
od235379/2019_2020 : Supply of following sizes of 1200 mm sweep. 5 star rated ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-Entrust 50 or equivalent approved make).

1036

-

-

... More
1.45 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

1097

-

-

... More
1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

1097

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

3640

-

-

... More
od235385/2019_2020 : Installation, testing and commissioning of wall light fittings of all types directly on wall including giving connections with required length of 16/0.2mm 3 core round copper conductor flex wire conforming to relevant ISS or with extended original wiring etc as required.

244

-

-

... More
od235391/2019_2020 : Installation, testing and commissioning of LED fittings with GI chain - Installation testing and commissioning of prewired fluorescent / LED fittings of all types complete with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.

17

-

-

... More
od235392/2019_2020 : P/F extra chain with copper wiring- Providing and fixing extra chain 2x10 cm length with using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor including painting etc. as required. (more than 5 cm length shall be rounded to the nearest 10 cm. and 5cm or less shall be ignored)

17

-

-

... More
od235396/2019_2020 : Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.

1

-

-

... More
od235400/2019_2020 : Installation, testing and commissioning of prewired, street light fittings of all types, complete with all accessories and lamp etc mounted on angle frame / GI pipe directly clamped to wall / welded to metallic structure/ excavation, plastering, grouting, finishing including connection with 1.5sq. mm PVC insulated copper conductor single core cable etc as required.

34

-

-

... More
1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

685

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

21

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required

41

-

-

... More
od235266/2019_2020 : Supply , providing ISI plate earthing as per IS 3043 with 1200x1200x12.5mm GI / CI earth plate with 20mm dia B class GI pipe for watering, 50x6mm GI strip welded to the plate, GI funnel with weld mesh, fixing GI strip of size 50x6mm with min. length of 20cm clamped with 50x5mm GI flat using 12x10mm GI bolt, nut at top of the GI pipe as test joint, filling around the GI pipe at a radius of 15cm with a homogeneous mixture of charcoal, river sand upto a height of 2.5 meter from the bottom, filling the rest of the portion with excavated soil including watering , ramming providing brick work (20cm) masonary at top in 1:6 cement mortar, plastering the inside , top of the manhole with 12mm thick 1:6 cement mortar and providing gully trap with 450x450x10mm CI covering at the top.

25

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
od235271/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 4mm GI (8 SWG)

200

-

-

... More
od235272/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 3.15mm Cu (10 SWG)

484

-

-

... More
od235275/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required 25x3mm Cu

120

-

-

... More
od235279/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.25x6mm GI strip

801

-

-

... More
od235283/2019_2020 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required. 50mm X10mm GI

180

-

-

... More
od235287/2019_2020 : Supply and fixing anodised aluminum glass framed shock treatment chart.

6

-

-

... More
od235297/2019_2020 : Supplying of Rubber hand gloves suitable for 11 KV.

8

-

-

... More
od235300/2019_2020 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

4

-

-

... More
od235303/2019_2020 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

8

-

-

... More
od235306/2019_2020 : Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement.

4

-

-

... More
od235313/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm) 50mm X10mm GI

510

-

-

... More
od235319/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm) 25mm X 6mm GI

130

-

-

... More
od235323/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm) 25mm X 3 mm Cu

160

-

-

... More
od235324/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm) 3.15mm Cu (10 SWG)

355

-

-

... More
od235332/2019_2020 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt , spring washer spaced at 50mm) 4mm GI (8 SWG)

2316

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
od235367/2019_2020 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

5

-

-

... More
od235376/2019_2020 : Supply and fixing of First aid box

6

-

-

... More
LIGHTNING PROTECTIONS

-

-

-

... More
od235262/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

2547

-

-

... More
od235264/2019_2020 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

1860

-

-

... More
od236629/2019_2020 : Providing and Fixing of Test Joint , suitable to fix 8 mm Aluminium conductor to 32 X 6 GI strip

48

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

1400

-

-

... More
od235282/2019_2020 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3 2Mtr Airterminal

16

-

-

... More
od235292/2019_2020 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3 4Mtr Airterminal

16

-

-

... More
EXTERNAL LIGHTINGS

-

-

-

... More
od235267/2019_2020 : Supply, installation, testing and commissioning of 5m long Hot dipped GI pole with foundation , built- in control box prewired, with pole suitable for mounting LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, provision for mounting RCBO/MCB in the control box as required and all other accessories complete on civil foundation. Along with LED Lamp with pressure die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 40(+/-5) watts, System efficacy not less than 110 lumen per watt , and lumen output greater than 4200 lumen, power factor 0.9, IP 65 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : UNIQUE POLES or equivalent approved make. Luminairie Make: WIPRO -LR02-451-XXX-57-XX or equivalent approved make) ITC

98

-

-

... More
od235269/2019_2020 : Supply, installation, testing and commissioning of 5m long Hot dipped GI pole with foundation , built- in control box prewired, with pole suitable for mounting LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, provision for mounting RCBO/MCB in the control box as required and all other accessories complete on civil foundation. Along with LED Lamp with pressure die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 40(+/-5) watts, System efficacy not less than 110 lumen per watt , and lumen output greater than 4200 lumen, power factor 0.9, IP 65 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.(Pole Make : UNIQUE POLES or equivalent approved make. Luminairie Make: WIPRO -LR02-451-XXX-57-XX or equivalent approved make) SUPPLY

98

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.