Kerala Water Authority Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date16 Dec 2021
Closing Date13 Jan 2022
Tender Amount₹ 2,13,53,216 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Amrut Wss To Guruvayur Municipality In Thrissur District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying 300 mm DI double flanged pipe

60

-

-

... More
Supplying 400 mm DI double flanged pipe

30

-

-

... More
Supplying 500mm DI K9 double flanged pipe

10

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 200mm.

2

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 300mm.

3

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 400mm.

1

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 500mm.

1

-

-

... More
Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 80mm.

8

-

-

... More
Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 80mm.

8

-

-

... More
Supplying an Electro magnetic flow meter of size 250mm confirming to protection level IP-68 for flow senser and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD unit suitable to measure the discharge of the transmission main of 300 mm DI . The flow meter should having the housing ( flow senser) to be made of SS 304/Carbon steel with anti corrosive protection and inside lining to be made up of Hard Rubber/ Neoprene are confirming to drinking water standard. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warantee position. Flow meter should be tested and calibrated at FCRI, Palakkad and test certificate should be produced. Flow meter should be calibrated with physical measurement at site after installation. A battery back of min 24 hrs should be provided.

3

-

-

... More
Supplying an Electro magnetic flow meter of size 400mm confirming to protection level IP-68 for flow senser and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD unit suitable to measure the discharge of the transmission main of 500 mm DI . The flow meter should having the housing ( flow senser) to be made of SS 304/Carbon steel with anti corrosive protection and inside lining to be made up of Hard Rubber/ Neoprene are confirming to drinking water standard. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warantee position. Flow meter should be tested and calibrated at FCRI, Palakkad and test certificate should be produced. Flow meter should be calibrated with physical measurement at site after installation. A battery back of min 24 hrs should be provided.

1

-

-

... More
Ductile Iron specials suitable for push on jointing upto 600 mm dia

107.36

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.