Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 5,00,000Document Cost
₹ 19,518Tender Fee
Refer Documents
Summary
Construction Of 5 Mld Capacity Stp With Cotreatnment Units At Elamkulam For Kochi Corporation Under Amrut 2 0 Design Construction And Commissioning Of 5 Mld Capacity Stp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KWA_710822_1Tender No
E-Tender No.03/2024-25/SE/PPD/KCNTender Authority
Kerala Water Authority ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General conditions of E Tendering Process
BOQ Items
OD141729/2024-2025: Design, Construction, Testing and Commissioning of Co-treatment units (Receiving Chamber with manual course screen, Screen Channel with manual course screen, Screw Press, OG Trap, Sludge Handling System, Channel for carrying water from screw press to dilution tank, Dilution tank with suitable cover slab and with suitable arrangements for mixing and homogenization , Arrangement for recycling treated water for dilution of septage with pre-determined dilution ratio with treated water to transfer liquid to screw press, Pump and Pumping main to pump water from dilution tank to receiving chamber of STP etc.) compatible to maximum 9 trucks per day with suitable foundation after conducting soil test, with required retention time to normalize parameters like BOD, COD, TSS etc. as per PCB and NGT standards (Receiving Chamber, Screen Channel, OG Trap, Channel for carrying water from screw press to dilution tank, Dilution tank with suitable cover slab shall be made with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better), septage vehicle travelling yard and discharge arrangements to receiving chamber and all necessary accessories for the satisfactory completion of work, corrosion resistant steel ladders, walkway and hand rails and all finishing works like plastering, painting, lettering etc. complete as per specification in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141730/2024-2025:Design, Construction, Testing and Commissioning of equalization tank with top cover slab with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better, suitable number of manholes with CI manhole covers, corrosion resistant steel ladders for STP compatible with the peak designed flow of 10 MLD including diluted septage (maximum 9 trucks per day) with suitable deep foundation after conducting soil test, with required retention time to normalize parameters like BOD, COD, TSS and volume of inflow etc. with aeration/ agitation arrangements to avoid anaerobic condition and odour and all finishing works like plastering, painting, lettering etc. complete including pumping arrangement (fitting of pump, pipe line works etc.) to pump liquid from equalization tank to MBBR-1, fitting fine bubble air diffusers with EPDM/PTFE+EPDM/any better material, pipelines to supply air and all accessories for the satisfactory completion of work as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141731/2024-2025:Design, Construction, Testing, and Commissioning of Moving Bed Biofilm-Reactor- Single Stage (MBBR-1) tank, Moving Bed Biofilm-Reactor- Single Stage Nitrification (MBBR-2) tank, Moving Bed Biofilm-Reactor- Anoxic De-nitrification (MBBR-3) tank, Moving Bed Biofilm-Reactor- Chamber after de-nitrification or final polishing (MBBR-4) tank with all necessary arrangements for the intended purpose of STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test, with required retention time as described in Vol-II of NIT to reduce parameters like BOD, COD, TSS etc. as per PCB and NGT standards. The MBBR tanks shall be made up with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches, with all finishing works like painting, lettering etc. complete including filling of required volume of MBBR media (high quality non-clogging, non-degradable, and with high attachability carriers as per specifications in Vol-II of NIT, carriers should have minimum specific surface area of 600m2/m3, specific gravity 0.98 or better to float/suspend in water). The bio-film formation and growth of suitable micro-organism using inoculation and seeding must be performed and sustained for the carrier before connecting to the sewage network/ co-treatment unit. Piping arrangements to flow liquid from one MBBR tank to next MBBR tank, fitting pipe and valve for removing sludge, fitting fine bubble air diffusers with EPDM/PTFE+EPDM/any better material, pipelines to supply air and protection arrangement to prevent escaping of MBBR media to next MBBR tank, fitting of agitator in MBBR-3, required bypass arrangements etc. to be done and all accessories for the satisfactory completion of work including ladders, walkway, hand rails etc. as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141734/2024-2025:Design, Construction, Testing and Commissioning of Secondary Clarifier (up flow sludge blanket and Plate/tube Settler Type) with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better for STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test, with required retention time to reduce parameters like TSS, TDS etc. as per PCB and NGT standards, without generating any biological nutrient removal process inside the clarifier, with all finishing works like painting, lettering etc. complete including fixing of SS plates, pipe line works and and all necessary pipe grid arrangements at the bottom to assist coagulation and dispension to develop sludge blanket at the mid height and flow channels, plate settler supporting structures at the top including all sludge removal system etc. complete. Necessary earth cutting shall be done to expose the Secondary Clarifier, constructing sludge removing arrangements including footsteps, piping arrangements, ladders, walkway, hand rails and all accessories for the satisfactory completion of work etc. as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141843/2024-2025:Design, Construction, Testing and Commissioning of Filter feed tank with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches for STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test, with required storing capacity to maintain sufficient suction head for pump, ladders, walkway, hand rails etc. including all finishing works like painting, lettering, fitting pipelines, pumps and all accessories for the satisfactory completion of work etc. as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141850/2024-2025:Design, Construction, Testing and Commissioning of Treated Water tank with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches for STP compatible with the designed flow of 5 MLD including diluted septage, with suitable deep foundation after conducting soil test, with required storage capacity to provide required treated water for diluting septage and re-use of water etc., with all finishing works like painting, lettering etc. complete including fitting pipelines, pumps etc. as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141842/2024-2025:Design, Construction, Testing and Commissioning of Sludge Sump with suitable cover slab with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches and facility for gas trapping for STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test, with required retention time and storage capacity, with suitable pump for sludge transfer to sludge thickener etc., with all finishing works like painting, lettering etc. complete and all accessories for the satisfactory completion of work as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141851/2024-2025:Design, Construction, Testing and Commissioning of Sludge Thickener with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches, Sludge Drying bed, for STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test, with required retention time to separate water from sludge using sludge thickening mechanism, pipe line to recycle separated water to equalization tank, pipe line and screw pump to pump separated sludge to centrifuge, with provision of polyelectrolyte dosing system, ladders, walkway, hand rails and all accessories for the satisfactory completion of work etc., with all finishing works like painting, lettering etc. complete as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141849/2024-2025:Design, Construction, Testing and Commissioning of Chlorine Contact Tank with RCC sulphate resistant cement M30 or better grade with water leak proofing coating,corrosion resistant TMT steel bars Fe415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches for STP compatible with the designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test. The tank should have enough volume to get required Chlorine contact time for disinfection, fitting Chlorinator, pipe line works , with all finishing works like painting lettering, ladders, walkway, hand rails etc. complete including all kinds of safety measures and all accessories for the satisfactory completion of work as per specification and as per the direction of departmental officers.
1
-
-
OD141848/2024-2025: Design, Construction, Testing and Commissioning of Chemical Room capable of storing chemicals required at least for 3 months usage by providing all kinds of safety measures, ventilation etc., Pump room to accommodate pumps and motors, Blower room for accommodating designed capacity air blowers including foundation with acoustic provision to avoid noise, transformer room to accommodate 250kVA indoor transformer and associate panel boards as per the standards of Electrical Inspectorate, foundation for 250 kVA generator with truss roofing, laboratory room including one operator rest room and toilet, required lab equipment, computers and furniture for STP with suitable deep foundation after conducting soil test, with brick walls, RCC lintels,projections, walkways,roofslabs etc wherever required with RCC M25 mix,TMT steel bars with all finishing works like painting, lettering etc. complete and all accessories for the satisfactory completion of work as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141847/2024-2025:Design, Construction, Testing and Commissioning of Alum and Lime mixing tanks with required volume to supply required volume of Alum and Lime solutions with designed concentration to collection channel from MBBR-4 tank to clarifier, pulley arrangements, fitting of mixing device like agitator with durable material if required, designed size and capacity for STP with designed flow of 5 MLD including diluted septage with suitable foundation after conducting soil test, with all finishing works like painting, lettering etc. complete and all accessories for the satisfactory completion of work as per specification and as per the direction of departmental officers.
1
-
-
OD141846/2024-2025:Design, Construction, Testing and Commissioning of Chlorine Room with required volume to supply required quantity of Chlorine to treated water through Chlorinator in Chlorine Contact Tank, with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better and all walls and slab junctions are to be provided with vertical and horizontal haunches by incorporating all types of safety measures and ventilation specified by the Ministry of Environment, Forest and Climate Change for STP with designed flow of 5 MLD including diluted septage with suitable deep foundation after conducting soil test and all accessories for the satisfactory completion of work including all finishing works like painting, lettering etc. as per specifications in Vol-II of NIT and as per the direction of departmental officers.
1
-
-
OD141742/2024-2025:Design, Supply, Erection, Testing and Commissioning of Mechanical items like pump sets with motors to pump sewage and water from various locations as per sepecification and hydraulic design, filter back wash pumps, with acoustic canopy air blowers with root aeration and high oxygen transfer efficiency with diffuser arrangements and pipe network as specified in Vol.II of NIT with acoustic canopy , air filters, pulleys, pressure gauge, pressure relief valve, suction silencer with suitable flanges, special pump to pump sludge from sludge thickener to centrifuge, SS bar screens (coarse and fine) for STP and Co-treatment unit, mechanical arrangements to clean screens, oil skimmer, mechanical grit removing arrangements, automatic control solid liquid separation unit with mechanical screw action for septage,mixing arrangements in dilution tank, mixing arrangement in anoxic tank, chemical mixing arrangements, required agitators, chemical dozing system, hypo dozing system, SS plates for plate settler or tube settler with high quality suitable material, bypass arrangements, fire fighting arrangements, steel ladders, sluice valves including conveyance, vacuum operated chlorinator, Pressure sand filter with minimum wall thickness 10mm with diameter 3m (3 working +1 standby) and rate of filteration as per specification , Activated carbon filter (3 working +1 standby) with minimum wall tickness 12mm with diameter 3.50m and rate of filteration as per specification, MBBR media, centrifuge system including foundation and centrifuge shed, air diffuser network in MBBR and equalization tank, air supply pipes from blower to various tanks, butter fly valves for air flow control, odor control unit, DI K(9) and PVC 10kg/cm2 pipes for interconnections, MS chequered plates for covering MBBR-3 & cable trenches, Incinerator for incinerating sludge cake from centrifuge and screw press of co-treatment unit etc. with required quantity and all accessories for the satisfactory completion of work complete as per specifications in Vol.II of NIT and as per the direction of departmental officers.
1
-
-
OD141743/2024-2025:Design, Construction, Testing and Commissioning of RCC platforms with RCC sulphate resistant cement M30 or better grade with water leak proofing coating, corrosion resistant TMT steel bars Fe 415 grade or better for Mechanical items like pump sets, air blowers, generator, screw press, PSF, ACF etc. wherever necessary with all works with required quantity, formation of all internal roads with paving interlocked tile, landscaping, eco-friendly exterior wall garden, green belt formation, ladders, hand rails etc. complete and all accessories for the satisfactory completion of work as per specification and as per the direction of departmental officers.
1
-
-
OD141744/2024-2025:Design, Supply, Erection,Testing and Commissioning of Electrical items like HT Cables, LT cables for connecting all equipments to power source and control units, HT and LT End Terminations, glanding, 250kVA Transformer (indoor type), 250kVA Generator set, various panel boards, electrical panels-Powder coated MCC panel shall be non-compartmentalized, free standing floor mounted, dust and vermin proof, switch gear, suitable OLR, SSBs, MSBs, Circuit Breakers, Isolators, Light Distribution boards, Lighting including lighting fixtures, switch boards, plug sockets, Tube lights, Neon Bulbs, Fans, pipe earthing and plate earthing (as per IS 3043), charges for document preparation, approval from Electrical Inspectorate and KSEB including consultancy charges if any, ON-OFF push buttons to motors and emergency OFF button near motors, Lightning arrestors, Cable Trays, Electromagnetic flow meter, normal flow meter, pressure gauges, level switches, CC TV with data recording system at septage unloading area, Solar Panels, IoT based sensors for water quality, central control system with flow recorder etc. with required quantity and capacity complete and contractor provisions as per the guide lines of electrical authority and all accessories for the satisfactory completion of work as per specification and as per the direction of departmental officers
1
-
-
OD141745/2024-2025:Operation and Maintenance Charge of STP and co-treatment units for 5 years including payment to operating and maintanance staff, cost of Chemicals, Fuel for Generator set, Spares of equipment, all types of repair works (material and labour), septage vehicle arrangement including any other unforeseen expenses etc. but excluding power charges.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%