Kerala Water Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KWA_706166_1Tender No
07/2024 25 /EE/KHDTender Authority
Kerala Water Authority ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General conditions of E Tendering Process
BOQ Items
OD100233/2024-2025:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation, Locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.
1
-
-
OD100244/2024-2025:11KV Metering Unit Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: Current Transformer CT Ratio 20/5 A (actual ratio may be decided after calculating connected load& maximum demand) Burden 15VA Accuracy Class 0.2S Potential Transformer PT ratio 11KV/110V Burden -100VA. Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB
1
-
-
OD100263/2024-2025:TOD Meter Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk includig supply and errection of the kiosk with suitable foundation. The TOD meter shall satisfy KSEB specifications in force.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences and supply and connecting cable from CTPT to metering equipment.
1
-
-
OD100266/2024-2025:Supply,erection, testing and commissioning of 250KVA, 11KV/433 V. 3phase, 50Hz. ONAN cooled , outdoor type copper wound power transformer, with HV side and LV side cable entry box arrangements, off load tap changer having +5% to -10% variations in 2.5% steps , and including first filling of oil , earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of neutral grounding CT, control cables both internal and external shall be included in the cost of Transformer. construction of suitable R.R. Masonry plinth for accomadating transformer etc.complete as per IS specification
1
-
-
OD105981/2024-2025:Design, Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation Load break switch with 11KV, 40kA rupturing capacity HRC fuse suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system, spring assisted, independent, trip free closing mechanism and all metering equipments, etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel. Panel shall include provision for installation of indoor type resin cast 11KV PT, CT and TOD meter with locking and sealing provision
1
-
-
OD100275/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
60
-
-
OD106101/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
8
-
-
OD100267/2024-2025:Supply installation testing and commissioning of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.6 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar, detachable covers for bus bar chamber and cable alley, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards , powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Incomer: 400A 4P 50 kA, Microproccessor based MCCB with 3O/C+1E/F - 1 Nos. Low set earth fault relay (EFR)for incomer, Digital Multifunction meter to read V,A,F,PF, etc. Indicator sets with necessary accessories and panel should be fully wired. Busbars: 250A Aluminium TPN. Outgoings: (1) :Microprocessor based 160A 36 kA 4P MCCB - 2 Nos. , (2) 100A 25kA 4P MCCB - 2 Nos (3) 63A 25KA 4P MCCB - 1No, with Digital multifunction meter with display for KW, V, A and pf for all outgoing feeders
1
-
-
OD100278/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
100
-
-
OD100279/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
1
-
-
OD100287/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
1
-
-
OD106023/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
50
-
-
OD106031/2024-2025:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
1
-
-
OD100288/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
4
-
-
OD100289/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
1
-
-
OD100290/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
1
-
-
OD100291/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
2
-
-
OD100319/2024-2025:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
1
-
-
OD100320/2024-2025:EARTHING - Supply and providing plate earhing as per IS 3043 by using 600mm x 600mm x 3mm thick copper plate with 2.7mtrs. Long 20mm dia 'B' class GI watering pipe extended upto middle of copper plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earh bus with copper plate by using 2 nos. 25x6mm copper strip of suitable length, filling charcoal and salt at alternate intervels of 15cm all aournd Copper plate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI
7
-
-
OD100321/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc
50
-
-
OD100322/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
100
-
-
OD100341/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
10
-
-
OD100340/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
10
-
-
OD100339/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
100
-
-
OD100338/2024-2025:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
100
-
-
OD100337/2024-2025:Supply and fixing of 6mm thick chequered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.
0.01
-
-
OD100336/2024-2025:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.
0.01
-
-
OD100335/2024-2025:Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.(11kv Rubber Mat- 8sets, 11 KV rubber glove-2 set, 11 KV danger board-10set, Fire bucket with stand-5 set, First aid box - 3 set, Shock treatmernt chart-4 sets, 5kg CO2 fire extinguisher 4 sets, 5kg dry powder fire extinguisher - 2 set
1
-
-
OD100334/2024-2025:Provision for soil resistivity measurement , earthing design, making electrical scheme drawing and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA)
1
-
-
Supply and erection of 120 HP motor cubicle control panel boards KSEB meter board, SFU, Fuse carrier
-
-
-
OD100451/2024-2025:Supply and Fabrication of control wiring transportation and errection of following types of cubicle panel board, KSEB meter board consists of following items, HB 800 fuse carrier, 250 HRC fuses 3no including 1no fuse foller provision for fixing 3PH energy meter CT chamber with sealing provision supply and transportation and labour charge
1
-
-
OD100457/2024-2025:Supply of main switch panel boards consists of following item, incomer 250 A TPN isolator - 1no, out goings. 250 A TPN SFU with 200 HRC fuse links-3no, 32A TPN SFU - 1no, switch interlock (3 locks with one key) RYB indicators with protection MCB, 1 set 500 V analog voltmeter with VSS- 1no, 250 A analog Ammeter, KW Meter, PF Meter
1
-
-
OD100450/2024-2025:Supply and laying 3.5 x 185sq mm aluminium UG cable
6
-
-
OD100449/2024-2025:Supply and providing cable end termination for 3.5 x 185 sq. AL UG cable
2
-
-
OD100448/2024-2025:Supply of laying 50 sqmm PVC insulated copper wire through suitable PVC conduct and accessories as required
40
-
-
OD100476/2024-2025:Supply and providing end termination for 50 sqmm PVC copper wire
12
-
-
OD100485/2024-2025:Supply and providing cable end termination for 3.5 x 400 sq AL UG cable
2
-
-
OD100484/2024-2025:Supply and providing cable termination for 3.5 x 70 sqmm AL UG Cable
2
-
-
OD100483/2024-2025:Supply of fixing and providing connection of 30 RVAR capacitor
1
-
-
OD100482/2024-2025:Supply of laying 16 sqmm PVC insulated copper wire through flexible conduct
6
-
-
OD100481/2024-2025:Supply of providing end termination 16 sq mm PVC copper wire
6
-
-
OD100480/2024-2025:Supply of laying 25 x 3 copper strip for earthins circuit
15
-
-
OD100479/2024-2025:Professional charges for the preperation and submission of completion report to KSEB for additional load (exclusive of all govt fee
1
-
-
OD100478/2024-2025:Labour charges towards erection of 120 HP motor cubicle control pannel boards KSEB meter Board, SFU, Fuse carrier etc as per the directions of departmental officers
1
-
-
Additional works at WTP and Pump House
-
-
-
OD106407/2024-2025:Supplying a Mechanical flow meter of Woltman type confirming to ISO 4064Class B and the flow meter shall be tested and certified by FCRI Palakkad - 150 mm dia
1
-
-
18.61.3:Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :150 mm dia
1
-
-
OD106558/2024-2025:Supply of Cast Steel Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 250mm.
1
-
-
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
1.09
-
-
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
1.82
-
-
10.25.2:Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
354
-
-
OD106542/2024-2025:Demolishing laterite wall in the chlorinator room and dismantling the existing rusted MS shutter etc as per the directions of department officers
1
-
-
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
9
-
-
10.29.1:Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
9
-
-
6.1.1:Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
2.52
-
-
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
26.4
-
-
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
26.4
-
-