Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Electrical Generators And Transformers
Eprocure
Opening Date10 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 10,04,88,702 
Notes
Download

Costs

  • EMD

    ₹ 5,00,000
  • Document Cost

    ₹ 16,540
  • Tender Fee

    ₹ 16,540

Summary

Jjm Wss To Nedumkandam Pampadumpara Upputhara Elappara Part And Arakulam Part Panchayaths In Idukki District Supply Erection And Commissioning Of

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OD62458/2023-2024:St Sebastian - Eden Garden Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge 38.2 lps,Total Head 100mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -3-Supply, Erection, Testing and commissioning of C/F water Pump set from EDEN Garden- Pampadumpara Estate

-

-

-

... More
OD64530/2023-2024:EDEN Garden- Pampadumpara Estate Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge 38.2 lps, Total Head 105mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -4-Supply, Erection, Testing and commissioning of C/F water Pump set from MG college- Bedumettu

-

-

-

... More
OD64977/2023-2024:MG college- Bedumettu Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge 28.64 lps,Total head -175m. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -5-Supply, Erection, Testing and commissioning of C/F water Pump set from MG College - Pushpakandam

-

-

-

... More
OD65138/2023-2024:MG College - Pushpakandam Supply,erection testing and commisioning of CF pump set with the following specification1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete. The duty condition is as follows,Discharge 37.25 lps, Total Head 150m. Modification may done for mono block pump sets<br>2. Motor Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA Soft starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -6-Supply, Erection, Testing and commissioning of C/F water Pump set from Onpathekar booster- Onpathekar GLSR

-

-

-

... More
OD66473/2023-2024:Onpathekar - Onpathekar GLSR Supply,erection testing and commisioning of CF pump set with the following specification1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 43 lps<br>Total head - 160 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

1

-

-

... More
Part -7-Supply, Erection, Testing and commissioning of C/F water Pump set from Bedumettu - Kailasapara

-

-

-

... More
OD66463/2023-2024:Bedumettu - Kailasapara Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 10.7 lps<br>Total head - 130 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -8-Supply, Erection, Testing and commissioning of C/F water Pump set from WTP-Kalyanathandu booster

-

-

-

... More
OD66458/2023-2024:WTP-Kalyanathandu booster Supply, erection testing and commissioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete The duty condition is as follows Discharge - 173.5 lps Total head - 125 mtrs. Modification may done for mono block pump sets 2. Motor :Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 3300V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter : Supply, erection, testing and commissioning of Soft starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. 4. ON-OFF Button:- Supply of On -Off and Emergency Stop buttons in a weather proof box and fixing near the Pump Motor, including supply of suitable control cable from the starter panel to motor side . 5.Cabling work: Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation 6.Earthing: Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor: Supply, erection, testing and commissioning of heavy-duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves: Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections: Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.

2

-

-

... More
Part -9-Supply, Erection, Testing and commissioning of C/F water Pump set from Kalyanathandu Booster-Kalyanathandu GLSR

-

-

-

... More
OD66456/2023-2024:Supply, erection testing and commissioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete The duty condition is as follows Discharge - 173.5 lps Total head - 125 mtrs. Modification may done for mono block pump sets 2. Motor :Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 3300V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter : Supply, erection, testing and commissioning of Soft starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. 4. ON-OFF Button:- Supply of On -Off and Emergency Stop buttons in a weather proof box and fixing near the Pump Motor, including supply of suitable control cable from the starter panel to motor side . 5.Cabling work: Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation 6.Earthing: Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor: Supply, erection, testing and commissioning of heavy-duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves: Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections: Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.

2

-

-

... More
Part 10. Supply, erection, testing and commissioning of 63 KVA Transformer at WTP site and kalyanathandu

-

-

-

... More
OD96442/2023-2024:HT EQUIPMENTS- DP STRUCTURE,11KV INCOMER WITH METERING, 11/3.3KV TRANSFORMER,CIVIL WORKS ETC-"Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc. as required.""Supplying and erection of a set of cross bracing frame work for11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint as required." "Erection of double pole 3 wire cross arm for 11kV/22kV/33 kV over head lines as required." "Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required." "Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.",Errection of 3pole 3 insulator type gang operated AB switch with operating pipe etc OUTDOOR HT BREAKER PANEL (LBS) with METERING Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set Voltmeter ( 0 - 11kV) - 3 Nos LED Pilot Indication - LBS ON / OFF - 1 Set Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set 230V AC Shunt Trip Coil - 1 No Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No CT - */5A, 15VA, CL 0.2S - 3 Nos Provisions for mounting 3 phase, wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set "Voltage Circuit: The active & apparent power consumption of voltage circuit including power supply of meter at reference voltage, reference temperature & frequency shall not exceed 1.0 Watt & 4.0 VA per phase "Current Circuit: The apparent power taken by current circuit at basic current, reference frequency & reference temperature shall not exceed 1.0 VA/phase. ( The Quoted rate shall be inclusive of necessary control wiring, components working on LT supply should be prewired completely with necessary controls as specified till the connection point for feeding LT Supply from outside, Cable end box for receiving incoming and outgoing cables and suitable civil foundation etc as required.)Supply & Labour. HT Bidirectional TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete. HT Equipment Pinth, Substation Yard Fencing & Levelling Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised. The rate shall be inclusive of all materials, labour, lead, lift etc including escalation works and fabrication and assembly works including all nuts, bolts and other miscallaneous items etc complete as per drawing and as directed by the Engineer in Charge. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick including cost and conveyance of all materials, labour charges etc complete Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). TRANSFORMER Supply, installation, testing and commissioning of one number 1000 kVA, DYn11, 3Ph, 50Hz, 11/3.3 kV, ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead, lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. NEUTRAL CT Supply & Providing 5P10 Protection Class 50/5A, 3.3 KV,15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc. complete

2

-

-

... More
OD111555/2023-2024:3.3 KV MAIN PANEL: Supply, erection, testing and commissioning of 3.3KV, 400 A, 75MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type panel board comprising of 1Nos. 400A Vacuum Circuit Breaker as incomer, 4 nos 400A Vacuum Circuit breakers as outgoing (2Nos for motors which are interlocked with each other) and one for 63KVA transformer and one as spare) The incomer switchgears, & outgoing switch gears should be of draw out type trip free VCBs with suitable overload, Earth fault and short circuit protection releases and Standby Earth fault relay through the neutral CT provided, suitable UV and shunt releases for probable integration to control wiring including PLC unit and its auxiliary systems for remote monitoring and operation and provision for future up gradation to SCADA, suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, MC 61A high set numerical protective relays, . resin cast, 3.3 KV /110/230V PT with control fuse for each incomers 0.2 class dual core CT LED panel indicates digital multi-function meters, with minimum features to read V, A, Hz, PF, THD % in all the outgoing feeders and incomers including suitable CT/PT and protection arrangements, panel, heaters with timer/RTD based automatic operation, suitable SMF battery and battery charger arrangements etc.. Complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel, 3.3KV Switch gear.

2

-

-

... More
OD111568/2023-2024:Neutral Grounding Resistor with neutral CT- Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR

2

-

-

... More
OD111570/2023-2024:HT Power Cables - Supply & laying 3.3KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 240 Sqmm

100

-

-

... More
OD111572/2023-2024:Supply and insulation of capacitor 3.3KV, 60KVR for power factor improvement above 0.95

2

-

-

... More
OD115344/2023-2024:Supply and installation of MSB panel board for 63KVA Transformer with 100A - 1 nos mccb as incomer and outgoing 63A 4p MCCB -4nos,EFR,neutral ct, indications,MFM with RS485 1 nos, voltmeter, 1 nos ammeter with suitable current transformer, suitable busbar and control wiring etc

2

-

-

... More
OD115345/2023-2024:Supply, erection, testing and commissioning of , 63 KVA, 3.3KV/433V. 3phase, 50Hz,Dyn 11,. Resin cast , Indoor type copper wound distribution transformers, with HV and LV side cable end box arrangements complete with all fittings as per IS 1180 L2 and Kerala Electrical Inspectorate norms and conforming to IS1180 ( Part 1 ). Armoured multi core 2.5 Sqmm copper control cables shall be used for all external &amp; internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.

2

-

-

... More
OD96440/2023-2024:Supply, installation, testing & commissioning of best quality sheet steel, phosphatised and painted, dust and vermin proof enclosure (IP43) Vertical TPN Double door DB including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing RCCB + Isolator (8 module )as incommer and SP/TP MCB as outgoings etc. on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing, dressing the DB including termination etc. as required. ( Including closing vaccant slots using Dummy ) 12 Way Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 63A, 100mA 3Ph RCCB 63A, 4P MCB Isolator 6A to 32A , 10kA SP MCB

2

-

-

... More
OD96439/2023-2024: CABLES , WIRES & ACCESSORIES HT Power Cables :- Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm,3C x 150 Sqm HT Cable Terminations: - Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm, 3C x 300 Sqmm LT Power Cables : - Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 5 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm, 3.5C x 50 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm, 3C x 4sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm, 3.5C x 50 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm, 3C x 4 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required.4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm, 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick, 25mm dia 1.5mm thick, 32mm dia 1.5mm thick Supply & providing Capping / Casing of good quality of the following sizes. 20 mm, 25 mm UG Cable Tamper Protection Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm, 80 mm, 100 mm Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness, 300 mm width X 50 mm depth X 1.6 mm thickness, 600 mm width X 50 mm depth X 2 mm thickness. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm, Above 35 sq. mm and upto 95 sq. mm ,Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

2

-

-

... More
OD96438/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate Earthing thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

2

-

-

... More
OD96437/2023-2024:Miscellaneous items: Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/ 1969. Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429/ 1969 in front of the HT Breaker Panel. Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. Supply and providing Laminated Electrical Schematic diagram framed and placed in a conspicuous location for clear vision. Supply & providing Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour at locations as directed by the Engineer in Charge.

2

-

-

... More
OD111580/2023-2024:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3.5 core 240 Sq.mm.3.3kv,XLPE AL Cable(Indoor)

10

-

-

... More
PART 11. Supply, erection, testing and commissioning of 250KVA Transformer at Booster Onpathekkar

-

-

-

... More
OD96456/2023-2024:DP structure,Incoming LBS with metering, 250KVA,Transformer with MV Panels etc: "Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc. as required." "Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint as required." "Erection of double pole 3 wire cross arm for 11kV/22kV/33 kV over head lines as required." "Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required." "Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required." OUTDOOR HT BREAKER PANEL (LBS) Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set Voltmeter ( 0 - 11kV) - 3 Nos LED Pilot Indication - LBS ON / OFF - 1 Set Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set 230V AC Shunt Trip Coil - 1 No Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No CT - */5A, 15VA, CL 0.2S - 3 Nos Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set "Voltage Circuit: The active & apparent power consumption of voltage circuit including power supply of meter at reference voltage, reference temperature & frequency shall not exceed 1.0 Watt & 4.0 VA per phase " Current Circuit: The apparent power taken by current circuit at basic current, reference frequency & reference temperature shall not exceed 1.0 VA/phase. ( The Quoted rate shall be inclusive of necessary control wiring, components working on LT supply should be prewired completely with necessary controls as specified till the connection point for feeding LT Supply from outside, Cable end box for receiving incoming and outgoing cables and suitable civil foundation etc as required.) HT Bidirectional TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete. HT Equipment Pinth, Substation Yard Fencing & Levelling Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised. The rate shall be inclusive of all materials, labour, lead, lift etc including escalation works and fabrication and assembly works including all nuts, bolts and other miscallaneous items etc complete as per drawing and as directed by the Engineer in Charge. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick including cost and conveyance of all materials, labour charges etc complete Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). Transformer Supply, installation, testing and commissioning of one number 250 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. NEUTRAL CT Supply & Providing 5P10 Protection Class 50/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete all rates including supply and labour.

1

-

-

... More
OD96457/2023-2024: MSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 400A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards). Incomer :- 400A FP Microprocessor based MCCB (35kA) with 3O/C and E/F releases -1no. Stand by Earth Fault Relay 1set, best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 4 Set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set,250/5A CL 1.0, 15VA Metering CTs - 1 Set. Outgoings: 250A FP Microprocessor based MCCB (35kA) - 3 Nos. 125A FP Microprocessor based MCCB – 3Nos 10A TP D curve MCB (10kA) - 1 Nos. Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible. All including supply and labour.

1

-

-

... More
OD96460/2023-2024: CABLES , WIRES & ACCESSORIES HT Power Cables :- Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm,3C x 150 Sqm HT Cable Terminations: - Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm, 3C x 300 Sqmm LT Power Cables : - Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm 3C x 6 Sqmm, 3C x 4 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required.4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm, 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick, 25mm dia 1.5mm thick, 32mm dia 1.5mm thick Supply & providing Capping / Casing of good quality of the following sizes. 20 mm, 25 mm UG Cable Tamper Protection Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm, 80 mm, 100 mm Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness, 300 mm width X 50 mm depth X 1.6 mm thickness, 600 mm width X 50 mm depth X 2 mm thickness. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm, Above 35 sq. mm and upto 95 sq. mm ,Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required., Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

1

-

-

... More
OD96461/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate Earthing thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

1

-

-

... More
PART 12. Supply, erection, testing and commissioning of 400KVA Transformer at CPAS nedumkandam

-

-

-

... More
OD96485/2023-2024:Supply and erection of 11kV DP structure, 400KVA Transformer ,etc with the following specifications: Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich11kV, 350 MVA, 630A, LBS unit - 1 setVoltmeter ( 0 - 11kV) - 3 Nos ,LED Pilot Indication - LBS ON / OFF - 1 Set,Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No,Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos,Space Heater Element with Thermostat & wiring - 1 Nos,Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No,CT - */5A, 15VA, CL 0.2S - 3 Nos,Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set Supply, installation, testing and commissioning of one number 400 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026 inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. Supply & Providing 5P10 Protection Class 50/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised including all nuts, bolts and other miscallaneous items. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick. Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 11 KV DP Structure: Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top. Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint Erection of. Supplying and erection of double pole 3 wire cross arm for 11kV/22kV/33 kV 11 kV pin insulator with large steel head G.I. pin, nuts, washers etc. Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc.

1

-

-

... More
OD96486/2023-2024: MSB for 400KVA Transformer: Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalized, dust tight, vermin proof, water proof 800A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards). Incomer :- 630A FP Microprocessor based 4P MCCB (35kA) Restricted Earth Fault Relay, 800A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 4 Set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set,200/5A CL 1.0, 15VA Metering CTs - 1 Set. Outgoings- 400A,4P MCCB 26KA – 2Nos ,250A 4P MCCB-2Nos ,125A 4P MCCB-2Nos Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. Supports All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth.The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible. Including erection testing and commissioning

1

-

-

... More
OD96488/2023-2024: Cables wires and accessories "Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments." 3C x 300 Sqm 3C x 150 Sqm HT Cable Terminations "Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required." 3C x 150 Sqmm 3C x 300 Sqmm LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm 3.5C x 50 Sqmm 3.5C x 35 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required. 4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 25mm dia 1.5mm thick 32mm dia 1.5mm thick Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Including cost of materials and labour

1

-

-

... More
OD96489/2023-2024:For 400 KVA transformer Earthing with 1200x1200x12.5 mm CI - Plate Earthing thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG) cost of materials and labour included

1

-

-

... More
Part 13 Power line Extension and Power connection charges to various pump houses

-

-

-

... More
OD98747/2023-2024: SCHEME APPROVAL & POWER ALLOCATION Preparation and submission of latest scheme drawings, Voltage drop calculations, Earthing design & fault level calculations to the Electrical Inspectorate including all MV additions recently made and obtaining approval, arranging inspection for entire installation, obtaining sanction orders for the electrical installation, complete (Including all incidental and statutory expenses ).

4

-

-

... More
OD98749/2023-2024:Approval from Electrical Inspectorate including preparation of drawings, obtaining approval for the drawings, arranging inspection of the installations and obtaining safety certificate et; after completion of the works. The necessary statutory fees, if any, payable to the Electrical Inspectorate / KSEB will be paid by KWA. (Note : Scheme approval from the Electrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials will be released only on production of scheme approval) including Energization approval from inspectorate and approvals from KSEBL.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.