Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Jul 2024
Closing Date13 Aug 2024
Tender Amount₹ 9,49,85,371 
Notes
Download

Costs

Summary

Jal Jeevan Missionwss To Chakkupallam Vandanmedu Karunapuram And Vandiperiyar Panchayats

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OD53623/2023-2024:WTP-0ttakathalamedu Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge 56lps,Total head 55mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -3-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from station WTP - Spring Valley- Discharge 100 lps, Head 25m

-

-

-

... More
OD53662/2023-2024:WTP-Spring Valley Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 100 lps<br>Total head - 25 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part - 4-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from stn Amaravathy to Market- Discharge 117 lps, Head 105m

-

-

-

... More
OD53747/2023-2024:Amaravathi-Market Supply, erection testing and commissioning of CF pump set with the following specification 1. Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete, The duty condition is as follows Discharge - 117 lps, Total head - 105 Mtrs.. Modification may done for mono block pump sets. 2. Motor - Supply, erection, testing and commissioning of KWA pre- qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V,IP 55 rating ,4 Pole . The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contactor as per IE rules and code of practice etc. complete 4. Panel board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs should have interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation 6.Earthing -Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthling GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

3

-

-

... More
Part -5 - Supply, Erection, Testing and commissioning of CF type CW Pumpsets from station Market to old WTP- Discharge 51 lps, Head 35m

-

-

-

... More
OD53790/2023-2024:Market-OLD WTP Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 51 lps,Total head - 35 mtrs.. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -6-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from Bethel to Thankamala - Discharge 6 lps, Head 135 m

-

-

-

... More
OD54175/2023-2024:Bethel-Thankamala Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 6 lps,Total head - 135 mtrs.. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part - 7-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from Odamedu to GLSR- Discharge 6 lps, Head 150 m

-

-

-

... More
OD53912/2023-2024:Odamedu - GLSR Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 6 lps,Total head - 150 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part - 8-Supply, Erection, Testing and commissioning of CF type CW Pumpsets fromOttakathalamedu Booster 1 to Booster 2 - Discharge 56 lps, Head 105m

-

-

-

... More
OD53843/2023-2024:Ottakathalamedu B1ooster 1 to Booster 2 Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 56 lps,Total head - 105 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part -9 -Supply, Erection, Testing and commissioning of CF type CW Pumpsets from Ottakathalamedu Booster 2 to GLSR- Discharge 56 lps, Head-120 m

-

-

-

... More
OD53819/2023-2024:Ottakathalmedu Booster 2 to GLSR Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 56 lps<br>Total head - 120 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part-10-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from Market to Vazhaveedu- Discharge 14lps, Head-120 m

-

-

-

... More
OD53798/2023-2024:Market- vazhaveedu Supply,erection testing and commisioning of CF pump set with the following specification<br>1. P Market- vazhaveeduump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 14 lps,Total head - 120 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part-11-Supply, Erection, Testing and commissioning of CF type CW Pumpsets from Wallardie to Odamedu- Discharge 11.5 lps, Head-100 m

-

-

-

... More
OD62261/2023-2024:Wallardie-Odamedu Supply,erection testing and commisioning of CF pump set with the following specification<br>1. Pump<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete<br>The duty condition is as follows<br>Discharge - 12 lps,Total head - 110 mtrs. Modification may done for mono block pump sets<br>2. Motor<br>Supply, erection, testing and commissioning of KWA pre qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300v motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.<br>3. Starter<br>Supply, erection, testing and commissioning of suitable rating (Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used.) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete.<br><br>4. Panel board (suitable for operating two pump sets but one pump set at a time)<br>Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified if there is only one)<br>pump set by changing 2 Nos of out going as one out going and the provision of interlocking may be avoided)<br>5.Cabling work<br>Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. considering energy conservation<br>6.Earthing<br>Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.<br>7. Capacitor<br>Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834<br>8. Valves<br>Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works.<br>9. Suction and delivery pipe connections<br>Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.<br>If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.<br>. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.

2

-

-

... More
Part-12-Supply,erection testing and commisioning of raw water pumpsets from Canal to Well

-

-

-

... More
OD151121/2022-2023:RWPM- Canal Design,supply, testing,errection and commissioning of submerged pumpsets with required starter, cables etc as per I.E.Rules for an operating head of 20 m and a total discharge of 277 lps, including cost of all required protection equipments , relays as per IE Rules , Supply of pressure guages, Electric connection , interconnection with the Raw water pumping main, trail run etc. including cost of 30 m cable length for each pumpset ,specials required for carrying out the connections etc complete.<br>1. The pump set shall be of Compact Unitary monoblock construction. The pump casing shall be of high efficiency, Volute or Bowl diffuser Casing type with the Impeller mounted directly onto the Extended Solid Motor Shaft (without any couplings). <br>2. The pump maybe mounted directly into the water body (Canal / Sump)<br>3. Suction Strainer : The pump is fitted directly with a Suction Bell mouth to which is compulsorily fitted a Heavy duty Strainer (to avoid pick up of gravel, pebbles, vegetation, etc.). As per Documents.<br>4. Induction Motor (Submerged) End Design : <br>4.1. The motor shall be of Squirrel Cage, Induction type, Air Filled yet capable of Water Immersion upto 20mwc for S1 duty – Motors with Oil or Water filled windings shall not be allowed.<br>4.2. It is rated for 4l5V for upto 335kW & HT for larger ratings ± 10 % V, 3 phase 50 ± 5% c/s A.C. Its winding should be of Class “F or H” insulation * while the nominal temp rise of winding hotspot should not exceed that of class “B”. <br>4.3. The Motor Rating should be higher of the two criteria : <br>• 5% over maximum power consuption through out the range of perfomance at 50 Hz. OR<br>• 15% more than the pump shaft power consumed at duty point at 50 Hz.<br>4.4. Motor Cooling the motor can be cooled just by water immersion <br>4.5. Motor Protection <br>4.5.1. Thermal Overload Protectors (Bi Metallic Over Load Relays) should be embedded in each phase of the stator winding to detect overheating & trip the motor from the control panel in the event of the temperature exceeding the safe operating limit (above 130?C). <br>4.5.2. To detect primary Mechanical Seal’s Leakage a Moisture Sensor shall be provided in intermediately Oil Chamber (& not in the Motor casing or else where) – this shall detect water mixing in oil by mode of increased leakage current from the moisture sensor.<br>4.5.3. Cables A watertight Cable Junction Box sealed from the motor shall be provided for the motor power and signaling cables. The cable shall be brought directly out of the submerged motor without joints, and shall be of sufficient length, minimum 10 m (to be seal jointed by the manufacturer for longer lenghts) outside adjacent to the wet well & above the HFL. They shall be sized in accordance with the electricity utility regulations and BS 7671. <br>5. Shaft & Bearings <br>5.1. The Solid Shaft shall be supported by heavy duty Ball or Roller bearings with a minimum L10 life of 75,000 hours & should be Permanently Greased <br>6. Stuffing Box / Oil Chamber <br>6.1. The pressurized entry of water into the motor (from the pump casing) should be prevented by Two separate mechanical seals in mounted in a Tandem mode within an oil chamber & the Primary (Inboard) seal should always be of Silicon Carbide or Tungsten Carbide faces to withstand erosive wear due to any silt particles.<br>(Efficiency-Min 70 %) extra 5% for additional1 year warranty above 2years normal warranty

2

-

-

... More
Part-13-Supply,erection testing and commisioning of raw water pumpsets from well to WTP

-

-

-

... More
OD62281/2023-2024:Supply,<br>erection, testing and commissioning of KWA approved make ISI marked high efficiency type , self water<br>lubricated above floor discharge type vertical turbine pump with bronze impeller , SS shaft , MS fabricated (minimum 8 mm ) flanged column assembly with strainer and all accessories conforming to IS 1710. The pump shall be coupled with suitable vertical hollow motor specified in item No. 2. Casing: Cast<br>iron<br>Speed: below 1500 rpm <br>Impeller : Enclosed type Bronze LTB 2 dynamically balanced as per<br>ISO1940 grade 3 standards<br>Sleeve: SS 304 <br>Colum shaft - SS 410 <br> Pump shaft - SS 316<br> Bowl Casing ring: Bronze LTB 2Epoxy painted MS Column pipe 10 mm Thick flanged ends each having length below 1.5 Meter. Strainer fabricated with SS 304 Bearings for spider and bowl synthetic Rubber with outer brass/CI shell <br>Discharge Head Bearing - Thrust / angular roller <br>Ratchet<br>assembly unlocking Centrifugally action <br><br>Minimum Efficiency: suitable to achieve minimum 70% efficiency for pump & motor<br>( Vibrations should be limited as per HIS 9.6.4.3 standards.<br>Pump performance tolerance should be subject to Hydrate Institute standard class A - No negative<br>tolerance is applicable in efficiency and no positive tolerance in power ).<br>Supply, erection, testing and commissioning of suitable rating high efficiency Kirlosker/crompton/BHEL/Marthon/Alstom or equivalent KWA approved make EF1 squirrel cage Induction,SPDP,Vertical hollow shaft motor suitable for direct<br>coupling with the above pump having RPM below 1500 or nearest capable to operate on voltage of<br>415V( /-10%)50 hz( /-3%)AC 3 phase,50 degree Ambient temp.rise. conforming to relevant IS. Motor<br>shall be energy efficient and supporting certificates to prove EF1 or EF2.<br>Design, supply, erection, testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight and vermin proof, indoor floor mounted cubicle type switch board fabricated out of 16 swg. Mild steel sheet for operation 3 phase, 415 volts 50 Hz, AC supply system. The panel board for one working a a time with 500 A SFU as incomer, change over switch for pumpsets, incoming main and 2 nos 250 Amps TPN SFU with HRC fuse as outgoing. The panel board consisting of voltmeter with selector switch, Ammeter CTS with selector switch, indication lamps necessary control<br>fuse base with HRC fuse and Nutral link etc.also one year Warrantee and Supply of ELCB/RCCB to be added at panel for safety. The switch board surface treated after degreasing, pickling, phospating etc anti-rust primer coating followed by two coats of spray paint of approved shade as standard construction practice approved by the Kerala Electrical Inspectorate standard and as standard practice.<br>Supply and fitting of suitable rating metalized heavy duty poly propylene (MDXL)power<br>capacitor with capacitor fixing stand, connecting copper cables, termination etc. suitable for the above motor as per IE rules. KVAR shall be provided for enhancing existing power factor to unity.<br>Supply and installation of suitable size,CI Double Flanged heavy duty Sluice Valve with cap PN 2.0, conforming to IS 14846 - 2000. The size shall not be less than the size of pump delivery<br>Supply and installation<br>of suitable size best quality, ISI marked heavy duty cast iron, double flanged reflux non return valve (PN2) as per IS: 5312, The size shall not be less than the size of pump delivery<br>Starter<br>Supplying<br>a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules with a power control MCB and line power contactor and the starting current shall be 2.50- 3.50 times the normal full load current of motor with ammeter, voltmeter and phase indicators, space<br>heaters, floor mounting type and having an insulation level of 1100 V. The standard is to be IEC 60947- 4.2.<br>Supply and installation of 150mm dia, Glycerence filled pressure gauge with stop cock/ valve to be fitted in a stand or wall visible while operating the valves with copper tube connections suitable for the above pumps.<br>Supply of all materials and providing suitable plate earthing with 200x1200x12mm CI plate buried in ground at a depth of 3m from ground level with alternate layers of charcoal and salt including the supply and fixing of 32mm dia preforated GI pipe, funnel for watering purposes, with MS/CI cover etc. as per IE standards conforming of IS 3043/87.<br>Supply, laying and giving earthing connections to motors, starters, capacitors, panel boards etc. using suitable size copper flat as per IE rules.<br>Supply, laying, termination and connecting of (Suitable size ) (AYFY/XLPE) insulated armoured Copper cable for working voltage up to 1100 volt confirming to relevant IS specification to lead cable from panel board to starter and starter to motor and starter to capacitor including terminations materials such as gland, socket, gland earth etc. as per IE rules.<br>Erecting the above motor pump set in suitable concrete foundation including fixing the starter, motor, cubical panel board including cost of all materials etc...Installing the electrical items, wiring and earthing, giving connection etc.as directed by the departmental officers as per IE rules and ISI specifications, fitting suction and delivery pipes and specials, Sluice valve, Reflux valve, Gauges etc. including clamping wherever necessary etc. complete and trial run for a period of one week to the satisfaction of the authority officers.<br>Including cost of all <br> the components specified above including 2 year warrantee

3

-

-

... More
Part 14. Supply, erection, testing and commissioning of 400 KVA Transformer at WTP site

-

-

-

... More
OD95344/2023-2024:Supply and erection of 11kV OUTDOOR SUBSTATION & HT EQUIPMENTS with the following specifications Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich11kV, 350 MVA, 630A, LBS unit - 1 setVoltmeter ( 0 - 11kV) - 3 Nos ,LED Pilot Indication - LBS ON / OFF - 1 Set,Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No,Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos,Space Heater Element with Thermostat & wiring - 1 Nos,Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No,CT - */5A, 15VA, CL 0.2S - 3 Nos,Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set,Voltmeter ( 0 - 11kV) - 3 Nos,LED Pilot Indication - LBS ON / OFF - 1 Set,Trip Push buttons - 1 set,2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No,Aluminium Busbar - 1 Set,Seal off Bushings - 3 Nos,Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No CT - */5A, 15VA, CL 0.2S - 3 Nos Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter. Supply, installation, testing and commissioning of one number 400 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026 inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. Supply & Providing 5P10 Protection Class 50/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised including all nuts, bolts and other miscallaneous items. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick. Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 11 KV DP Structure Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top. Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint Erection of. Supplying and erection of double pole 3 wire cross arm for 11kV/22kV/33 kV 11 kV pin insulator with large steel head G.I. pin, nuts, washers etc. Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc.

1

-

-

... More
OD95425/2023-2024:LT / MV PANELS & ACCESSORIES MSB: - Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 630A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incomer: - 630A 36KA FP Microprocessor based MCCB (35kA) with Built-in Earth Fault Release,630A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 4 Set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set,630/5A CL 1.0, 15VA Metering CTs - 1 Set. Outgoing:- 250A 36KA Microprocesser based MCCB 4 nos 125A 36KA Microprocesser based MCCB 4 nos Surge Protection: - Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. SSB: - Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 200A MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incoming: - 200A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set, RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 1 Set,200/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings:- 160A FP Microprocessor based MCCB (35kA) - 3 Nos. 10A TP D curve MCB (10kA) - 1 Nos. APFC PANEL: - Automatic Power Factor Correction Panel of total 40 KVAR capacity with Auto / Manual mode operation to be fabricated out of 14 gauge CRCA sheet steel Powder coated with provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components(refer particular specification) with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry , free standing panel consisting of the following as per standards. 63A TPN Isolator - 1 No. 100 A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set. RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches- 1 Set100/5A 15VA CL 1.0 Metering CTs - 3 Sets Microprocessor based intelligent, 8 step IPFC relay with PF display - 1 No.Out goings 20A, 10kA C Curve TP MCB - 5 Nos 10A, 10kA C Curve TP MCB - 2 Nos 6A, 10kA C Curve TP MCB - 3 Nos. Capacitor duty contactors working on 3 Phase 415V AC supply of the following ratings wired with Pilot LED indication for ON & OFF, Push Buttons for Manual ON & OFF operation using suitable NO / NC contacts for all the stages .10 kVAr- 3 Nos, 7.5 kVAr- 4 Nos, 480 V,50 Hz Double di-electric polypropylene ( MPP heavy duty ) Capacitors of the following ratings including fixed compensation for low load losses. 10 kVAr- 3 Nos, 5 kVAr- 1 Nos, 2 kVAr - 2 Nos,1 kVAr - 1 Nos Supports All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth.The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible.

1

-

-

... More
OD95734/2023-2024: DISTRIBUTION BOARDS, SWITCHGEAR & ACCESSORIES Supply, installation, testing & commissioning of best quality sheet steel, phosphatised and painted, dust and vermin proof enclosure (IP43) Vertical TPN Double door DB including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing RCCB + Isolator (8 module )as incommer and SP/TP MCB as outgoings etc. on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing, dressing the DB including termination etc. as required. ( Including closing vaccant slots using Dummy ) 12 Way Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 63A, 100mA 3Ph RCCB 63A, 4P MCB Isolator 6A to 32A , 10kA SP MCB

1

-

-

... More
OD95742/2023-2024: CABLES , WIRES & ACCESSORIES HT Power Cables :- Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm,3C x 150 Sqm HT Cable Terminations: - Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm, 3C x 300 Sqmm LT Power Cables : - Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm 3C x 6 Sqmm, 3C x 4 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required.4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm, 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick, 25mm dia 1.5mm thick, 32mm dia 1.5mm thick Supply & providing Capping / Casing of good quality of the following sizes. 20 mm, 25 mm UG Cable Tamper Protection Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm, 80 mm, 100 mm Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness, 300 mm width X 50 mm depth X 1.6 mm thickness, 600 mm width X 50 mm depth X 2 mm thickness. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm, Above 35 sq. mm and upto 95 sq. mm ,Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required., Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

1

-

-

... More
OD95753/2023-2024:For 400 KVA transformer Earthing with 1200x1200x12.5 mm CI - Plate (8 nos) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip for connecting transformers, panels, motors to the earthing main. Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG) for various other earth needs. cost of materials and labour included

1

-

-

... More
OD95754/2023-2024:Miscellaneous items: Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/ 1969. Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429/ 1969 in front of the HT Breaker Panel. Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. Supply and providing Laminated Electrical Schematic diagram framed and placed in a conspicuous location for clear vision. Supply & providing Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour at locations as directed by the Engineer in Charge.

1

-

-

... More
Part 15: Supply, erection, testing and commissioning of 750 KVA Transformer at Well site

-

-

-

... More
OD95865/2023-2024:Supply and erection of 11kV OUTDOOR SUBSTATION & HT EQUIPMENTS with the following specifications 1.Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich11kV, 350 MVA, 630A, LBS unit - 1 set Voltmeter ( 0 - 11kV) - 3 Nos ,LED Pilot Indication - LBS ON / OFF - 1 Set, Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No, Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos, Space Heater Element with Thermostat & wiring - 1 Nos, Inspection Lamp LED with switch & wiring - 1 set 2)11kV Load Break Swich- 11kV, 350 MVA, 630A, LBS unit - 1 set, Voltmeter ( 0 - 11kV) - 3 Nos, LED Pilot Indication - LBS ON / OFF - 1 Set, Trip Push buttons - 1 set,2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No, Aluminium Busbar - 1 Set, Seal off Bushings - 3 Nos, Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set 3)Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No, CT 3 nos- */5A (rating as per contract demand) 15VA, CL 0.2S - 3 Nos, Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set 4)Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter. 5)Supply, installation, testing and commissioning of one number 750kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV, ONAN cooled, copper wound outdoor distribution transformer with tapings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026 inclusive of all materials, lead, lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. 6)Supply & Providing 5P10 Protection Class 250/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc. Complete 7)Providing, fabricating and fixing 2m high chain-link fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chain-link fencing shall be Hot Dip Galvanised including all nuts, bolts and other miscellaneous items. 8)Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick. 9)Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 10)11 KV DP Structure Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top. Supplying and erection of a set of cross bracing frame work for 11 kV overhead line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint Supplying and erection of double pole 3 wire cross arm for 11kV/22kV/33 kV 11 kV pin insulator with large steel head G.I. pin, nuts, washers etc. Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc.

1

-

-

... More
OD96252/2023-2024:Medium voltage Panels and accessories MSB: - Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 1200A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incomer: - 1200A FP ACB (35kA) - 1 Nos. Restricted Earth Fault Relay - 1 Set 1200A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 4 Set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set 1200/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoing: - 400A 36KA Microprocesser based MCCB 3 nos 200A 36KA Microprocesser based MCCB 3 nos 125A 36KA Microprocesser based MCCB 2 nos Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. SSB: - Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 200A MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incoming: - 200A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, Multifunction Digital Panel meter to read V, A,F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set, RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 1 Set,200/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings: 160A FP Microprocessor based MCCB (35kA) - 3 Nos. 10A TP D curve MCB (10kA) - 1 Nos. APFC PANEL :- Automatic Power Factor Correction Panel of total 40 KVAR capacity with Auto / Manual mode operation to be fabricated out of 14 guage CRCA sheet steel Powder coated with provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components(refer particular specification) with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry, free standing panel consisting of the following as per standards. 63A TPN Isolator - 1 No. 100 A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set. RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches- 1 Set100/5A 15VA CL 1.0 Metering CTs - 3 Sets Microprocessor based intelligent, 8 step IPFC relay with PF display - 1 No Out goings 20A, 10kA C Curve TP MCB - 5 Nos 10A, 10kA C Curve TP MCB - 2 Nos 6A, 10kA C Curve TP MCB - 3 Nos. Capacitor duty contactors working on 3 Phase 415V AC supply of the following ratings wired with Pilot LED indication for ON & OFF, Push Buttons for Manual ON & OFF operation using suitable NO / NC contacts for all the stages .10 kVAr- 3 Nos, 7.5 kVAr- 4 Nos, 480 V,50 Hz Double di-electric polypropylene (MPP heavy duty) Capacitors of the following ratings including fixed compensation for low load losses. 10 kVAr- 3 Nos, 5 kVAr- 1 Nos, 2 kVAr - 2 Nos,1 kVAr - 1 Nos Supports All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible.

1

-

-

... More
OD96377/2023-2024:Supply, installation, testing & commissioning of best quality sheet steel, phosphatised and painted, dust and vermin proof enclosure (IP43) Vertical TPN Double door DB including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing RCCB + Isolator (8 module )as incommer and SP/TP MCB as outgoings etc. on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing, dressing the DB including termination etc. as required. ( Including closing vaccant slots using Dummy ) 12 Way Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 63A, 100mA 3Ph RCCB 63A, 4P MCB Isolator 6A to 32A , 10kA SP MCB

1

-

-

... More
OD96364/2023-2024: CABLES , WIRES & ACCESSORIES HT Power Cables :- Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm,3C x 150 Sqm HT Cable Terminations: - Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm, 3C x 300 Sqmm LT Power Cables : - Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm 3C x 6 Sqmm, 3C x 4 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required.4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm, 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick, 25mm dia 1.5mm thick, 32mm dia 1.5mm thick Supply & providing Capping / Casing of good quality of the following sizes. 20 mm, 25 mm UG Cable Tamper Protection Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm, 80 mm, 100 mm Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness, 300 mm width X 50 mm depth X 1.6 mm thickness, 600 mm width X 50 mm depth X 2 mm thickness. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm, Above 35 sq. mm and upto 95 sq. mm ,Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required., Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

1

-

-

... More
OD96376/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate (8 nos) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

1

-

-

... More
OD96375/2023-2024:Miscellaneous items: Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/ 1969. Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429/ 1969 in front of the HT Breaker Panel. Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required. Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. Supply and providing Laminated Electrical Schematic diagram framed and placed in a conspicuous location for clear vision. Supply & providing Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour at locations as directed by the Engineer in Charge.

1

-

-

... More
Part 16: Supply, erection, testing and commissioning of 200 KVA Transformers

-

-

-

... More
OD96451/2023-2024:Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc. as required. Supplying and erection of a set of cross bracing frame work for 11 kV overhead line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint as required. Erection of double pole 3 wire cross arm for 11kV/22kV/33 kV overhead lines as required. Supplying and erection of 11 kV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. "Supplying and erection of three-piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. OUTDOOR HT BREAKER PANEL (LBS) Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set, Voltmeter (0 - 11kV) - 3 Nos, LED Pilot Indication - LBS ON / OFF - 1 Set, Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set, 230V AC Shunt Trip Coil - 1 No, Aluminium Busbar - 1 Set, Seal off Bushings - 3 Nos, Space Heater Element with Thermostat & wiring- 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No, CT - */5A, 15VA, CL 0.2S - 3 Nos Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set Voltage Circuit: The active & apparent power consumption of voltage circuit including power supply of meter at reference voltage, reference temperature & frequency shall not exceed 1.0 Watt & 4.0 VA per phase Current Circuit: The apparent power taken by current circuit at basic current, reference frequency & reference temperature shall not exceed 1.0 VA/phase. (The Quoted rate shall be inclusive of necessary control wiring, components working on LT supply should be prewired completely with necessary controls as specified till the connection point for feeding LT Supply from outside, Cable end box for receiving incoming and outgoing cables and suitable civil foundation etc as required.) Supply & Labour HT Bidirectional TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete. HT Equipment Plinth, Substation Yard Fencing & Levelling Providing, fabricating and fixing 2m high chain-link fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chain-link fencing shall be Hot Dip Galvanised. The rate shall be inclusive of all materials, labour, lead, lift etc including escalation works and fabrication and assembly works including all nuts, bolts and other miscellaneous items etc complete as per drawing and as directed by the Engineer in Charge. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick including cost and conveyance of all materials, labour charges etc complete Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). Transformer Supply, installation, testing and commissioning of one number 200 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV, ONAN cooled, copper wound outdoor distribution transformer with tapings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead, lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. NEUTRAL CT Supply & Providing 5P10 Protection Class 50/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.

2

-

-

... More
OD96541/2023-2024:MSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 400A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incomer: - 400A FP Microprocessor based MCCB (35kA) Earth Fault Release, 400A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 4 Set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set,200/5A CL 1.0, 15VA Metering CTs - 1 Set. Outgoing: - 125A 36KA based MCCB 4 nos 63A 36KA based MCCB 2 nos Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. Supports All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible.

2

-

-

... More
OD96448/2023-2024: CABLES , WIRES & ACCESSORIES "Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments." 3C x 300 Sqm 3C x 150 Sqm HT Cable Terminations "Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required." 3C x 150 Sqmm 3C x 300 Sqmm LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm 3.5C x 50 Sqmm 3.5C x 35 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required. 4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 25mm dia 1.5mm thick 32mm dia 1.5mm thick Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

2

-

-

... More
OD96447/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate (8 nos) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

2

-

-

... More
Part 17: Supply, erection, testing and commissioning of 315 KVA Transformer at 3rd Mile

-

-

-

... More
OD96500/2023-2024:11 KV outdoor sub station and HT equipments: Supply and erection of 11kV OUTDOOR SUBSTATION & HT EQUIPMENTS with the following specifications Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components.11kV Load Break Swich11kV, 350 MVA, 630A, LBS unit - 1 set Voltmeter ( 0 - 11kV) - 3 Nos ,LED Pilot Indication - LBS ON / OFF - 1 Set,Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No,Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos,Space Heater Element with Thermostat & wiring - 1 Nos,Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No,CT - */5A, 15VA, CL 0.2S - 3 Nos,Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set,Voltmeter ( 0 - 11kV) - 3 Nos,LED Pilot Indication - LBS ON / OFF - 1 Set,Trip Push buttons - 1 set,2NO+2NC Aux contacts - 1 Set,230V AC Shunt Trip Coil - 1 No,Aluminium Busbar - 1 Set,Seal off Bushings - 3 Nos,Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No CT - */5A, 15VA, CL 0.2S - 3 Nos Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter. Supply, installation, testing and commissioning of one number 315 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026 inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. Supply & Providing 5P10 Protection Class 100/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised including all nuts, bolts and other miscallaneous items. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick. Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 11 KV DP Structure Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top. Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint Erection of. Supplying and erection of double pole 3 wire cross arm for 11kV/22kV/33 kV 11 kV pin insulator with large steel head G.I. pin, nuts, washers etc. Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc.

1

-

-

... More
OD96535/2023-2024:MSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 800A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards) Incomer: - 630A FP Microprocessor based MCCB (35kA) Restricted Earth Fault Relay,800A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves as per ISS - 1set, RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 4 Set, Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set, 420/5A CL 1.0, 15VA Metering CTs - 1 Set. Outgoing: - 250 A 36KA MCCB – 3 nos 125 A 36KA MCCB – 3 nos Surge Protection: - Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set. Supports All the panels shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible.

1

-

-

... More
OD96496/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate (8 nos) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

1

-

-

... More
OD96497/2023-2024: CABLES , WIRES & ACCESSORIES "Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments." 3C x 300 Sqm 3C x 150 Sqm HT Cable Terminations "Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required." 3C x 150 Sqmm 3C x 300 Sqmm LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm 3.5C x 50 Sqmm 3.5C x 35 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required. 4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 25mm dia 1.5mm thick 32mm dia 1.5mm thick Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150 mm width X 50 mm depth X 1.6 mm thickness 300 mm width X 50 mm depth X 1.6 mm thickness 600 mm width X 50 mm depth X 2 mm thickness Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

1

-

-

... More
Part 18: Supply, erection, testing and commissioning of 160 KVA Transformer at Market

-

-

-

... More
OD97328/2023-2024:Supply and erection of 11kV OUTDOOR SUBSTATION & HT EQUIPMENTS with the following specifications 11kV DP STRUCTURE "Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc. as required." "Supplying and erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nut setc. (as per drawing) and painting with primer and finish paintas required." "Erection of double pole 3 wire cross arm for 11kV/22kV/33 kV over head lines as required." "Supplying and erection of 11 kV pin insulator complete withlarge steel head G.I. pin, nuts, washers etc. as required.""Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required." OUTDOOR HT BREAKER PANEL (LBS) Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich, 11kV, 350 MVA, 630A, LBS unit - 1 set, Voltmeter ( 0 - 11kV) - 3 Nos, LED Pilot Indication - LBS ON / OFF - 1 Set Trip Push buttons - 1 set, 2NO+2NC Aux contacts - 1 Set, 230V AC Shunt Trip Coil - 1 No, Aluminium Busbar - 1 Set, Seal off Bushings - 3 Nos Space Heater Element with Thermostat & wiring - 1 Nos, Inspection Lamp LED with switch & wiring - 1 set, Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No, CT - */5A, 15VA, CL 0.2S - 3 Nos Provisions for mounting 3 phase,4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass. 1-set "Voltage Circuit: The active & apparent power consumption of voltage circuit including power supply of meter at reference voltage, reference temperature & frequency shall not exceed 1.0 Watt & 4.0 VA per phase" Current Circuit: The apparent power taken by current circuit at basic current, reference frequency & reference temperature shall not exceed 1.0 VA/phase. HT Bidirectional TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete. HT Equipment Pinth, Substation Yard Fencing & Levelling Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised. The rate shall be inclusive of all materials, labour, lead, lift etc including escalation works and fabrication and assembly works including all nuts, bolts and other miscallaneous items etc complete as per drawing and as directed by the Engineer in Charge. Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick including cost and conveyance of all materials, labour charges etc complete Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). Transformer Supply, installation, testing and commissioning of one number 160 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications. NEUTRAL CT Supply & Providing 5P10 Protection Class 50/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete

1

-

-

... More
OD97325/2023-2024:Earthing with 1200x1200x12.5 mm CI - Plate (8 nos) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required. Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG) 3.15 mm copper conductor ( 10 SWG) 4.00 mm copper conductor ( 8 SWG) 4.75 mm copper conductor (6 SWG)

1

-

-

... More
OD97326/2023-2024: CABLES , WIRES & ACCESSORIES HT Power Cables :- Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm,3C x 150 Sqm HT Cable Terminations: - Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm, 3C x 300 Sqmm LT Power Cables : - Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm, 3C x 6 Sqmm Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm, 3.5C x 300 Sqmm, 3.5C x 35 Sqmm, 4C x 16 Sqmm, 4C x 6 Sqmm, 4C x 4 Sqmm, 3C x 35 Sqmm, 3C x 25 Sqmm, 3C x 16 Sqmm 3C x 6 Sqmm, 3C x 4 Sqmm Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required.4C x 2.5 Sqmm Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm, 3C x 1.5 Sqmm PVC Conduits Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick, 25mm dia 1.5mm thick, 32mm dia 1.5mm thick Supply & providing Capping / Casing of good quality of the following sizes. 20 mm, 25 mm UG Cable Tamper Protection Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm, 80 mm, 100 mm Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire, 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire, 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness, 300 mm width X 50 mm depth X 1.6 mm thickness, 600 mm width X 50 mm depth X 2 mm thickness. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm, Above 35 sq. mm and upto 95 sq. mm ,Above 95 sq. mm and upto 185 sq. mm Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required., Upto 35 sq. mm (clamped with 1mm thick saddle) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m) Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required. Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

1

-

-

... More
OD97327/2023-2024:Medium Voltage Panels Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 400A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incomer: - 250A FP Microprocessor based MCCB (35kA) - 1 Nos. Restricted Earth Fault Relay - 1 Set 160A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 4 Set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set 200/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoing: - 160 A MCCB- 3 nos 125 A MCCB- 3 nos Surge Protection: - Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set" Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible. Supply & Labour SSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 200A MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards (All switches shall confirm to conforming to IEC 60947-2 standards). Incoming: 100A TPN Isolator - 1 No. 200A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set RYB indicators (LED Pilot type) with 2A Control MCB and toggle switches - 1 Set, 100/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings: 63A FP MP MCCB (36kA) - 3 Nos. Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extension be possible.

1

-

-

... More
Part-19-Power line Extension and Power connection charges to various pump houses

-

-

-

... More
OD97203/2023-2024:Approval from Electrical Inspectorate including preparation of drawings, obtaining approval for the drawings, arranging inspection of the installations and obtaining safety certificate et; after completion of the works. The necessary statutory fees, if any, payable to the Electrical Inspectorate / KSEB will be paid by KWA. (Note : Scheme approval from the Electrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials will be released only on production of scheme approval) including Energization approval from inspectorate and approvals from KSEBL.

4

-

-

... More
OD97238/2023-2024: SCHEME APPROVAL & POWER ALLOCATION Preparation and submission of latest scheme drawings, Voltage drop calculations, Earthing design & fault level calculations to the Electrical Inspectorate including all MV additions recently made and obtaining approval, arranging inspection for entire installation, obtaining sanction orders for the electrical installation, complete (Including all incidental and statutory expenses ).

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.