Kerala Water Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 2,00,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KWA_684419_1Tender No
RT-33/SE/PHC/TSR/2024-25Tender Authority
Kerala Water Authority ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General conditions of E Tendering Process
BOQ Items
... More
OD186714/2023-2024:Payment to be made to KSEB as ECSC (Estimated cost of Service connection) for taking new service connection, Cash Deposit etc
1
-
-
... More
OD186720/2023-2024:Drawing 1Km of 11 kV ABC of size 3X120 + 1X95 on 9 mts supports with an average span of 20-25 mts (Rate as per KSERC approved data)
100
-
-
... More
OD186726/2023-2024:MV Panel Boards (Main SB)- Design, engineering, supply erection, testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight & vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, PVC sleeved, air insulated and of adequate size as mentioned below, for operation on 3 Phase, 4wire, 415 Volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be of reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. Main Switch board (MSB) 400A TPN bus bars Earthing conductor: 25x6 mm, copper. Incomer- 250A 36kA, 4 pole Thermal Magnetic release, Isolation duty MCCB with 3 O/C & 1 E/F release set at 225 A – 1No, 200 A ,25KA TP MCCB - 2Nos ,125 A ,25KA TPN MCCB-1No and 63A,25KA TPN MCCB .1No as outgoings and shall be fitted with metering chamber for KSEBL metering having sealing facility for meter chamber and CT Chamber with adequate space for accommodating LT TOD meter and should be provided with 4 Nos Resin Cast Current transformers on the Incoming side of Class 0.5S, 10VA ,200/5A capacity and with other Metering equipments like voltmeters, ammeters, selector switches, indicating lamps etc
1
-
-
... More
OD187606/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185Sqmm
2
-
-
... More
OD187607/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5C x 185Sq mm
40
-
-
... More
OD186729/2023-2024:LT TOD Meter-Supply, erection, testing and commissioning of LT TOD meter of reputed make, 415V, 3 Phase 4 wire,Class 0.5S -/5A, with data downloading port.
1
-
-
... More
OD186999/2023-2024:Testing and Conveyance Charges for testing of 4Nos LT resin cast CTs (4Nos)and TOD Meter at TMR testing lab of KSEBL
1
-
-
... More
OD187017/2023-2024:PIPE EARTHING WITH 2.5M PIPE -Supply and providing pipe earthing as per IS 3043 with 2.5 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
5
-
-
... More
OD187018/2023-2024:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
4
-
-
... More
OD187023/2023-2024:Supply & laying the following sizes of Earth Strip for earthing interconnection, termination and leads, for continous earthing along with cables tinned at terminals etc. complete. 25 x 6 mm Copper Strip
50
-
-
... More
OD187024/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x3mm copper strips.
50
-
-
... More
Madakkathara panchayath -Supply, Erection,Testing & Commissioning of Clear Water Pumpset at Kachithod CF Pump-54 HP, H= 97 m, Q=28.47 lps
-
-
-
... More
OD102631/2023-2024:Design, Supply, erection, testing and commissioning, 54 HP Centrifugal motor pump set having Discharge - 28.47 LPS and Head - 97m, including maintenance for 2 years of pumpset and includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge - 28.47 lps, Total head - 97 mtrs.. Modification may done for mono block pump sets 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star-Delta Starter for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with Main, Delta and Star contactors etc. complete 4. Motor Control Panel Board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation 5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.
2
-
-
... More
OD187502/2023-2024:Testing and Conveyance Charges for testing of 4Nos LT resin cast CTs (4Nos)and TOD Meter at TMR testing lab of KSEBL
1
-
-
... More
OD187503/2023-2024:LT TOD Meter-Supply, erection, testing and commissioning of LT TOD meter of reputed make, 415V, 3 Phase 4 wire,Class 0.5S -/5A, with data downloading port.
1
-
-
... More
OD187504/2023-2024:MV Panel Boards (Main SSB)- Design, engineering, supply erection, testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight & vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, PVC sleeved, air insulated and of adequate size as mentioned below, for operation on 3 Phase, 4wire, 415 Volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be of reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. Main Switch board (MSB) 400A TPN bus bars Earthing conductor: 25x6 mm, copper. Incomer- 200A 36kA, 4 pole Thermal Magnetic release, Isolation duty MCCB with 3 O/C & 1 E/F release set at 133 A – 1No, 125 A ,25KA TP MCCB - 2Nos ,and 63A,25KA TPN MCCB - 2No as outgoings and shall be fitted with metering chamber for KSEBL metering having sealing facility for meter chamber and CT Chamber with adequate space for accommodating LT TOD meter and should be provided with 4 Nos Resin Cast Current transformers on the Incoming side of Class 0.5S, 10VA ,200/5A capacity and with other Metering equipments like voltmeters, ammeters, selector switches, indicating lamps etc
1
-
-
... More
OD187559/2023-2024:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5C x 95Sq mm
30
-
-
... More
OD187601/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185Sqmm
2
-
-
... More
OD187505/2023-2024:Payment to be made to KSEB as ECSC (Estimated cost of Service connection) for taking new service connection, Cash Deposit etc
1
-
-
... More
OD187506/2023-2024:PIPE EARTHING WITH 2.5M PIPE -Supply and providing pipe earthing as per IS 3043 with 2.5 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
5
-
-
... More
OD187507/2023-2024:Drawing 1Km of 11 kV ABC of size 3X120 + 1X95 on 9 mts supports with an average span of 20-25 mts
70
-
-
... More
OD187510/2023-2024:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
4
-
-
... More
OD187512/2023-2024:Supply & laying the following sizes of Earth Strip for earthing interconnection, termination and leads, for continous earthing along with cables tinned at terminals etc. complete. 25 x 6 mm Copper Strip
40
-
-
... More
OD187513/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, LT panel boards, equipments and inter connection of earth pits etc. 25x3mm copper strips.
40
-
-
... More
Pananchery panchayath-Supply, Erection,Testing & Commissioning of Clear Water Pumpset at peechi-CF pump 48 HP, H-103m , Q=22.6 lps
-
-
-
... More
OD102633/2023-2024:Design, Supply, erection, testing and commissioning, 48 HP Centrifugal motor pump set having Discharge - 22.60 LPS and Head - 103m, including maintenance for 2 years of pumpset and includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge - 22.60 lps, Total head - 103 mtrs.. Modification may done for mono block pump sets 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star-Delta Starter for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with Main, Delta and Star contactors etc. complete 4. Panel board (suitable for operating two pump sets but one pump set at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation 5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.
2
-
-
... More
Puthur panchayath-Supply, Erection,Testing &Commissioning of Clear Water Pumpset at Peechi-CF pump -160 HP, H-167m, Q-98.03 lps
-
-
-
... More
OD139999/2023-2024:Design, Supply, erection, testing and commissioning, 160 HP Centrifugal motor pump set having Discharge - 98.03 LPS and Head - 167m, including maintenance for 2 years of pump set It includes 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge – 98.03 lps, Total head - 167 mtrs.. 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete For 3300V motors digital motor protection relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty Soft Starter for the above motor with over voltage and under voltage protections, Single phasing preventer, Over load relay with motor protection relays, and shall be provided with multifunction digital meter and indicators. 4. Panel board (suitable for operating three pump sets but to run two pump sets at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 3 Nos of suitable capacity MCCB as outgoing (the outgoing MCCBs are to be fitted with interlocking facility so that two of them can be operated at a time) providing suitable size Aluminium/Copper bus bars to inter connect the above MCCBs and is to be fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per CEA regulations and code of practice. The panel shall be fitted on a common base frame on suitable foundation 5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.
3
-
-
... More
OD187881/2023-2024:Supply & laying of three runs of XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5C x 240Sq mm
180
-
-
... More
OD187880/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 240Sqmm
6
-
-
... More
OD187885/2023-2024:SSB at Pumping Station- Fabrication of a fully partitioned dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 ( with latest amendments) using 2.00 mm CRCA sheet as per approved design and requirement with front access facility bus bar chambers with 800A TPN Copper/Aluminium Bus bars with insulator supports, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley having entry of incomer and outgoing cables from top as well as bottom , powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/Flats/slotted angles etc shall not be used for the fabrication of panel assembly with the following Switch Fuse Units hving isolation rating with DIN type HRC fuses - MSB Incomer: 800A 4P - 1 No, digital multi-function meter to read V, A,F,PF,KW, KWh etc. Indicator sets with necessary accessories and panel should be fully wired and Copper bus bars for Phases, Neutral & Common earth bus, Busbar 800A TPN. Outgoings: 630A 4P SFU-2 Nos (One for taking supply to 160HP Motor Change over Panel and one spare), 160A SFU- 3 nos (one for supplying the 50HP motor change over panel and one for future APFC panel and one spare), 100A SFU -1No ( for future lighting purpose) for mounting at clear water pump house etc. done as per the direction of departmental officers.
1
-
-
... More
OD188381/2023-2024:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
5
-
-
... More
OD188382/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of LT panel boards, equipments and inter connection of earth pits 25X 6MM COPPER STRIP
30
-
-
... More
OD188383/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of LT panel boards, equipments and inter connection of earth pits 25X 6MM COPPER
30
-
-
... More
Construction of Pump station at Peechi
-
-
-
... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
10.04
-
-
... More
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
2.99
-
-
... More
OD103793/2023-2024:Dry rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) including cost of through stone and bond stone.
6.16
-
-
... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
3.47
-
-
... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.43
-
-
... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
3.31
-
-
... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
23.71
-
-
... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.88
-
-
... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
0.09
-
-
... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
397.44
-
-
... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
4.2
-
-
... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
117.29
-
-
... More
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
117.29
-
-
... More
13.82.2:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
117.29
-
-
... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
4.2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%