Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date31 Dec 2024
Closing Date10 Jan 2025
Tender Amount₹ 34,89,376 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.

352

-

-

... More
100.98.214:Supply of PVC Pipe, 6kg/cm2, 110mm Dia.

50

-

-

... More
OD159088/2024-2025:Plugging the full portion of the mouth of 225 to 300mm dia sewer main using clay filled gunny bags and removing the same after completion of work etc complete.

4

-

-

... More
OD159094/2024-2025::Plugging the full portion of the mouth of 150mm to 200mm dia sewer main using clay filled gunny bags and removing the same after completion of work etc complete

4

-

-

... More
OD159093/2024-2025:Plugging the full portion of the mouth of 100mm dia sewer main using clay filled gunny bags and removing the same after completion of work etc complete

6

-

-

... More
OD159089/2024-2025:Plugging the full portion of the mouth of 350 to 375mm dia sewer main using clay filled gunny bags and removing the same after completion of work etc complete.

4

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

1743

-

-

... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

0.27

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

5.94

-

-

... More
OD159095/2024-2025:Supplying, conveying and laying 25mm dia PVC best quality pipe (10kg/cm2) including specials for diverting near manholes

10

-

-

... More
19.21.3:Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 350 to 450 mm diameter

5

-

-

... More
OD159091/2024-2025:Manhole cleaning above 3m depth- <br>Cleaning the manhole at main line and branches above 3m depth including removing the silt and other floated matters and destroying the debris at convenient places as directed by the departmental officers

2

-

-

... More
100.98.1008:Engaging Coolie.

15

-

-

... More
100.98.1035:Engaging sewer man.

10

-

-

... More
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.

11.7

-

-

... More
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

6

-

-

... More
CONSTRUCTION OF MANHOLES

-

-

-

... More
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

12

-

-

... More
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.

24

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

18

-

-

... More
100.1.2:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

18

-

-

... More
100.1.3:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 3m but not exceeding 4.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

18

-

-

... More
100.1.4:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 4.5m but not exceeding 6m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

18

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

6.24

-

-

... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining

58.44

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.4

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

1.94

-

-

... More
5.7:Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

9.86

-

-

... More
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

933.55

-

-

... More
19.21.1:Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 100 to 250 mm diameter

5

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

3.09

-

-

... More
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

3.39

-

-

... More
19.16:Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

18

-

-

... More
19.1.6:Providing, laying and jointing glazed stoneware pipes class SP - 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand) including testing of joints etc. complete:300mm diameter

3.6

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

36.86

-

-

... More
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.

43.2

-

-

... More
OD160477/2024-2025: :Supplying and fixing in position 560 mm dia. CI Cover (heavy duty-HD20) with frame the weight to be not less than 208 kg

3

-

-

... More
OD160483/2024-2025:Providing Steel Sheet shoring to the sides of the trenches to depths upto 2.00 M using 5mm M>S Sheet 0.5m wide stiffen on edges with 50mm x50mmx6mm M.S angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.50m above ground level suitably braced by horizontal walling pieces at 75MMX100 MMx 8MM angles on either side at intervals not exceeding 1.5M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed ,dismantling,cleaning restacking for reuse including all labour,hire charges and conveyance for equipments ,tools and plants and sundries etc .complete.

48

-

-

... More
OD160995/2024-2025:Providing Steel Sheet shoring to the sides of the trenches to depths of ABOVE 2 M But Not exceeding 4 M using 6mm MM SS Sheet 0.5m wide stiffen on edges with 50mm x50mmx6mm M.S angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipment's and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.50m above ground level suitably braced by horizontal walling pieces at 75MMX125MMx 8MM angles on either side at intervals not exceeding 1.5M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed ,dismantling, cleaning restacking for reuse including all labor, hire charges and conveyance for equipment's ,tools and plants and sundries etc. .complete. Hire charges for 6mm MS sheet. (Data given as per close timbering)

32

-

-

... More
Pipe Laying HDD Method

-

-

-

... More
OD160511/2024-2025:Laying and installation of HDPE- 400MM dia, PE-80, (PN-8)- IS-14333 pipe by horizontal directional drilling method in all types of soil above/below water table up to 8m depth for gravity sewer including preparing, and setting up the plant and equipment, installing new pipe work, testing and commissioning excluding cost of pipe (6m line pipe with butt joint) all related civil/mechanical works like entry/exit pits as necessary. Dewatering, drilling, stringing, reaming, pulling back the new pipe on the designed alignment and monitoring by approved guidance system. Wastage of pipes, proper disposal of drilling fluid/bentonite slurry. Proper back filling of pit and holes by approved borrow material as per specification, approved method statement or as directed by Engineer in charge

100

-

-

... More
OD160980/2024-2025:Charges for Sorting the required quantity 400 mm dia pipe from the KWA stock yard of various sizes of 6m length HDPE pipes stacked in a mixed manner including hire charges of crane, man coolies etc

1

-

-

... More
OD160985/2024-2025:Transporting 400mm HDPE pipes and specials. Loading and unloading 400 mm dia HDPE Pipes having length 12 m/each at KWA store yard and work site(15km average ) respectively including hire charges of crane at both sites,charges of man coolies for assisting etc complete.

100

-

-

... More
Material Supply

-

-

-

... More
100.98.166:Supply of HDPE Pipe PE 100 (IS 4984/1995), 10kg, 400mm Outer Dia.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.