Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Civil Works Others
Water Storage And Supply
Eprocure
Opening Date6 Nov 2024
Closing Soon25 Nov 2024
Tender Amount₹ 14,11,35,811 
Notes
Download

Costs

Summary

Amrut 2 0 Cochin Corporation Construction Of Glsr 15ll And Ohsr L5 Ll Capacity Supply And Erection Of Pumpsets Interconnection

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
50.2.33.6:Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete

40

-

-

... More
50.2.33.7:Cutting branches of trees overhanging above any structures of girth between 90cm to 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete.

18

-

-

... More
50.2.33.8:Cutting branches of trees overhanging above any structures of girth beyond 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete.

12

-

-

... More
15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet

145.07

-

-

... More
15.14.1:Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above

4.65

-

-

... More
15.15.1:Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one metre or par thereof beyond 10 metres:Of sectional area 40 square centimetres and above

20

-

-

... More
15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

265

-

-

... More
15.26:Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

966

-

-

... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

99.6

-

-

... More
15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

169.68

-

-

... More
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

357

-

-

... More
15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar

62.28

-

-

... More
OD39758/2024-2025:Demolishing laterite work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In lime mortar

121.08

-

-

... More
15.8.3:Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m ( stacks of cleaned bricks shall be measured )From brick work in cement mortar

31140

-

-

... More
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

162.3

-

-

... More
15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

20

-

-

... More
15.36:Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.

295.08

-

-

... More
100.98.1008:Engaging Coolie.

25

-

-

... More
OD39759/2024-2025:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge,upto a lead of 5 kilometers, for all leads including all lifts involved

298.32

-

-

... More
OD39760/2024-2025:Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 5 kilometres, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

169.68

-

-

... More
15.18:Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

458.88

-

-

... More
Construction of 15LL Capacity OHSR at Perumanoor pump house - Part 1 - Cost of Materials

-

-

-

... More
100.98.119:Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia.

100

-

-

... More
100.98.121:Supply of DI K9 Pipe Conforming to IS 8329/2000, 400mm Dia.

50

-

-

... More
100.98.122:Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia.

50

-

-

... More
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.

50

-

-

... More
100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.

3

-

-

... More
100.98.465:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 400mm.

4

-

-

... More
100.98.466:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm.

8

-

-

... More
OD39761/2024-2025:Supply of 450 mm Dia Double Flanged (screwed/welded) Centrifugally (Spun) Cast Iron, Class B ( IS: 1536): for column pipe of OHSRs

86.5

-

-

... More
OD39762/2024-2025:Supply of 400 mm Dia Double Flanged (screwed/welded) Centrifugally (Spun) Cast Iron, Class B ( IS: 1536): for column pipe of OHSRs

49.5

-

-

... More
OD39763/2024-2025:Supply of 300 mm Dia Double Flanged (screwed/welded) Centrifugally (Spun) Cast Iron, Class B ( IS: 1536): for column pipe of OHSRs

42.5

-

-

... More
18.30.7:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe

16

-

-

... More
18.30.9:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:400 mm diameter pipe

18

-

-

... More
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe

30

-

-

... More
18.70.5:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe

20

-

-

... More
18.70.7:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:400 mm dia pipes

10

-

-

... More
18.70.8:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes

10

-

-

... More
18.70.10:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes

10

-

-

... More
OD39764/2024-2025:Supply of DI specials.

80.74

-

-

... More
Construction of 15LL Capacity OHSR & 15LL GLSR with pump room at Perumanoor pump house - Part 2 - Working Charges

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1928.7

-

-

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

594.73

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

376.25

-

-

... More
20.2.4:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).500 mm dia piles

1624

-

-

... More
20.2.5:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia piles

2320

-

-

... More
OD39734/2024-2025:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).<br>700 mm dia piles

2784

-

-

... More
20.6.1.1:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile upto 50 tonne capacityInitial test

1

-

-

... More
20.6.3.1:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Group of two or more piles upto 50 tonne capacityInitial test

1

-

-

... More
20.6.1.2:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile upto 50 tonne capacityRoutine test

1

-

-

... More
20.6.3.2:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Group of two or more piles upto 50 tonne capacityRoutine test

1

-

-

... More
15.58:Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

35.26

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

100.4

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

460.26

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

1031.77

-

-

... More
5.38:Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

431.73

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

1492.03

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

351.35

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1767.03

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2370.5

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2134.34

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1609.26

-

-

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

158.67

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

596818.16

-

-

... More
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

100.71

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

4756.03

-

-

... More
OD39735/2024-2025:12 mm cement plaster of mix 1:4 ( 1 cement : 4 fine sand) .ht 10 to 13m. Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3m or part thereof. Upto 13m ht.

697.15

-

-

... More
OD39736/2024-2025:12 mm cement plaster1:4 ( 1 cement : 4 fine sand) .ht 13 to 16m. Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3m or part thereof.Upto 16m ht.

693.67

-

-

... More
OD39737/2024-2025:12 mm cement plaster: 1:4 ( 1 cement : 4 fine sand) .ht 16 to 20m. .Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3m or part there of. Upto 20m ht.

901.33

-

-

... More
OD39738/2024-2025:12 mm cement plaster: 1:4( 1 cement : 4 fine sand) .ht 20 to 25m. Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3m or part there of.Up to 25m ht.

1459.75

-

-

... More
OD39739/2024-2025:12 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 ( 1 cement : 3 fine sand) .ht 19 to 24m., inside of the OH Tank including adding 2% water proofing compound by weight of cement

2188.23

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

2188.23

-

-

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

8507.93

-

-

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

7086.75

-

-

... More
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

397.95

-

-

... More
11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm

30.81

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

6335.87

-

-

... More
OD39740/2024-2025:Conveying and fixing wall casting pipe in the RCC slab / wall of tank as per the direction of departmental officers.

15

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

45

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

71

-

-

... More
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

86

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

15

-

-

... More
21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

3.3

-

-

... More
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

3

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

8.4

-

-

... More
OD39741/2024-2025:Providing 110mm PVC pipe and tees for vent hole with PVC Vent cowl,bend & 'T' at ends including cost and coveyance of materials.

12

-

-

... More
OD39742/2024-2025:Providing 110mmCI pipe and tees for vent hole with PVC Vent cowl,bend & 'T' at ends including cost and coveyance of materials.

28

-

-

... More
OD39743/2024-2025:Providing and fixing CI Manhole cover 750mmX750mm with outer frames(heavy duty)

4

-

-

... More
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.

1675

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

3750

-

-

... More
OD39744/2024-2025:Supplying and fixing Mechanical Water level indicators

2

-

-

... More
OD39745/2024-2025:Supply and installation of lightening protection sytem (Lightening arresters) made of non corrosive materials ,utilize advance ance and sustainable technologie , maintain a 5 year replacement guarantee,15 years service Warranty, independently tested and certified to NFc17102and UNE21186 standards with a protection radius of minimum 560m by capturing dangerous lightening discharges and safely channeling it to earth

1

-

-

... More
OD39746/2024-2025:Supplying and fixing 450mm electro-magnetic flow meter conforming to protection level of IP- 68 for Flow Sensor and IP-67 for transmitter and having andaccuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/Carbon steel with anti-corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions.

2

-

-

... More
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

75

-

-

... More
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.

50

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

50

-

-

... More
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.

50

-

-

... More
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)

75

-

-

... More
OD39747/2024-2025:Labour for cutting DI pipe with steel saw - 400mm diameter DI pipe

6

-

-

... More
100.15.5:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 300mm diameter Ductile Iron Double Flanged pipes.

42.5

-

-

... More
100.14.5:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 300mm diameter Ductile Iron Class K-9 Pipes.

100

-

-

... More
100.14.7:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 400mm diameter Ductile Iron Class K-9 Pipes.

50

-

-

... More
100.15.7:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 400mm diameter Ductile Iron Double Flanged pipes.

49.5

-

-

... More
100.35.5:Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA

100

-

-

... More
100.35.7:Testing 400mm DI/CI pipeline with potable water to the required test pressure. 400 mm dia Observed Data derived from item no.1026 of PHED DATA

50

-

-

... More
100.35.8:Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA

50

-

-

... More
100.35.10:Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA

50

-

-

... More
100.14.8:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 450mm diameter Ductile Iron Class K-9 Pipes.

50

-

-

... More
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.

50

-

-

... More
100.15.8:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 450mm diameter Ductile Iron Double Flanged pipes.

86.5

-

-

... More
18.24:Laying in position S & S or flanged C.I. special such as tees, bends, collars, tapers and caps etc. ( excluding cost of specials).

82.81

-

-

... More
100.31.1.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class I.

3

-

-

... More
100.31.1.9:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 400mm diameter, Class I.

4

-

-

... More
100.31.1.10:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 450mm diameter, Class I.

8

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

73.13

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

10.27

-

-

... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

1.93

-

-

... More
OD39748/2024-2025:Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B

20

-

-

... More
OD39749/2024-2025:Supply, laying and connecting of earthing conductor of GI. flat/copper wires including necessary earth trenches, jointing as per IS : 3043/87 in trenches, walls, pulling through pipes etc. Copper wire No. 10 SWG

25

-

-

... More
OD39750/2024-2025:Supply, fixing and connect 6A 3 pin plug socket and control switch in same light control box complete with labour

6

-

-

... More
OD39751/2024-2025:Supply and errection of reputed make 4 feet LED tube light fitting with tube on ceiling /wall and connect the same with light points with 1.5 sq.mm PVC insulated flexible copper wire complete with labour

10

-

-

... More
OD39752/2024-2025:Supply and fixing angle batten holder with LED (12 Watts) lamp and connect light point complete with labour

2

-

-

... More
OD39753/2024-2025:Supply and fixing reputed make 20 Watts out door LED street light fitting and connect the same with light points complete with labour

2

-

-

... More
OD39754/2024-2025:Supply and fixing reputed make 1400mm sweep 3 blade with plug type electronic stage regulator and connect the same with fan point complete with labour.

10

-

-

... More
OD39755/2024-2025:Supply and fixing reputed make 300mm sweep exhaust fan and connect the same with fan points complete with labour

3

-

-

... More
OD39756/2024-2025:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required as per IS - 3043 complete with labour.

1

-

-

... More
OD39757/2024-2025:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&amp;80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer

4

-

-

... More
100.37.9.1:In situ fabrication of M.S. pipes of size 300mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

10

-

-

... More
100.37.9.2:Fabricating M.S. flanges of diameter 300mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.9.3:Cutting 300mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.9.4:Welding 300mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

3

-

-

... More
100.37.9.5:Grinding cut and weld edges of 300mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.11.1:In situ fabrication of M.S. pipes of size 400mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

20

-

-

... More
100.37.11.2:Fabricating M.S. flanges of diameter 400mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

16

-

-

... More
100.37.11.3:Cutting 400mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.11.4:Welding 400mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.11.5:Grinding cut and weld edges of 400mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.12.1:In situ fabrication of M.S. pipes of size 450mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

20

-

-

... More
100.37.12.2:Fabricating M.S. flanges of diameter 450mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

20

-

-

... More
100.37.12.3:Cutting 450mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.12.5:Grinding cut and weld edges of 450mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.12.4:Welding 450mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

10

-

-

... More
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

8

-

-

... More
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

6

-

-

... More
Supply and erection 80HP C/F pump set

-

-

-

... More
OD39765/2024-2025:Supply , erection , testing and commissioning of best quality approved make horizontal split case centrifugal pump sets having a discharge of 141 lps against a total head of 30m, length of suction pipe 10m (approximately), including all accessories with the following specifications. 1. Pump - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal split case centrifugal pump sets having a discharge of 141 lps against a total head of 30m with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V . The motor shall confirm to EEF1/IS 325 and its amendments including providing suitable concrete foundation including cost of cement sand and metal etc. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty Soft Starter suitable for 415V system for the above motor with over voltage and under voltage protection, single phase preventer, over load relay and shall be provided with main contactor and bypass contactor as per Standards complete. 4. Panel board (Suitable for operating one Pump set at a time and one pump standby) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCBs (all motor isolation type) as outgoing (the two outgoing MCCBs should have interlocking facility so that only one will be running at a time) providing suitable size Aluminium/Copper bus bars and inter connecting the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per statutes. The panel shall be fitted on a common base frame on suitable foundation 5. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 6.Earthing - Supply of all materials and providing suitable earthling and linking the same to the main earth bud using suitable size copper strips/conductors buried in ground or clamped on RCC/wall and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 8. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided

2

-

-

... More
Valve chamber and Anchor blocks

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

94.76

-

-

... More
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

10.73

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

42.27

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

44.27

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6057.66

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

27.21

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

551.19

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

455.04

-

-

... More
Electrical works

-

-

-

... More
OD39723/2024-2025:SSB at new Pump house : Fabrication ,Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board made out of 14SWG thick CRCA sheet fully compartmentalised, and painted with epoxy paints of approved colour and quality, complete with hinged and earthed front doors, name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, Digital multi function meters, ammeters with CTs, Protection relays and Voltmeter with selector switch, all connections and inter-connections including mounting the following switch gears. (the panel shall be fabricated by a ISO and CPRI approved vendor with SC,HRT,IP 42,IEC 61439 Type Test Certificate) (Provision for energy meter in all outgoings shall be provided, Protection relays shall be provided as per electrical inspectorate standard) The switch board should have suitable rated TPN Aluminium / Cu busbars with specified current, fault level and insulated with SMC/DMC busbar supports, colour coded heat shrinkable PVC sleeves complete (a) Incomer: 400A 4P 50kA Current limiting type MCCB with thermal magnetic releases - 1 No, Outgoing:-320A, 36kA 4P MCCB - 2 No , 250A 36kA 4P MCCB - 2 Nos , 63A ,36kA 4P MCCB -2, metering, protection relays, multi function meters and indications etc and sufficient earthing shall be provided as per CEA regulations and EI guidelines.

1

-

-

... More
OD106346/2024-2025:Supply ,fixing, testing and commissioning of 1 no heavy duty 400A , 4 Pole , Switch fuse unit of reputed make including HRC fuse links , extension rod, operating handle etc in the spare cubicle of the existing 500KVA Transformer panel (MSB) including necessary fabrication work, Bus bar extension/ interlinking , welding work ,earthing etc

1

-

-

... More
OD39724/2024-2025:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 2 Runs from existing MSB to new SSB and for interconnecting Changeover panel to SSB 3.5*185 Sqmm AYFY

250

-

-

... More
OD39731/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5*185 Sqmm AYFY

8

-

-

... More
OD39726/2024-2025:Supply , Laying and termination of 25*3 COPPER earthing strip to various equipments and earth bus

100

-

-

... More
OD106350/2024-2025:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required

60

-

-

... More
OD39727/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.

5

-

-

... More
OD39728/2024-2025:Supply and Laying 4*4 Sqmm AYFY

30

-

-

... More
OD106313/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 4Cx4Sqmm

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.