Kerala Water Authority Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Mar 2025
Closing Soon2 Apr 2025
Tender Amount₹ 1,63,75,382 
Notes
Download

Costs

Summary

Amrut 2.0 - Swap 3.0 Package 2 Augumentation Of Uwss To Thodupuzha Providing Full Coverage To House Holds Of Thodupuzha Municipality

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

39.75

-

-

... More
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

150

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

500

-

-

... More
OD196291/2024-2025:Inter connection newly laid line from 150 mm DI to 160mmm PVC / 150 DI distribution line using saddle/tee and other specials supplied by the contractor required without causing any damages to pipe including lighting watching etc complete<br>

2

-

-

... More
OD196290/2024-2025:Inter connecting the newly laid line to existing various size PVC/GI distribution line using appropriate size of saddle clamps/tee and other specials supplied by the contractor required without causing any damages to pipe including lighting watching etc complete as per direction.

15

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

100

-

-

... More
18.12.5:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore

2262

-

-

... More
OD196300/2024-2025:Cutting,Grinding &amp; Welding 40 mm GI pipe and specials by gas cutting,the cut edges /welded portions in MS pipe grind by grinding machine,after grinding three run welding including cost of welding rod /gas, all labour and hire charges of tools and machines etc complete

140

-

-

... More
100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.

258

-

-

... More
OD196297/2024-2025:Cutting, Grinding &amp; Welding 150 mm GI pipe and specials by gas cutting ,the cut edges /welded portions in MS pipe grind by grinding machine, after grinding three run welding including cost of welding rod /gas, all labour and hire charges of tools and machines etc complete

40

-

-

... More
OD196299/2024-2025:Testing 150mm GI pipeline with potable water to the required test pressure 150 mm dia Observed Data derived from item no.1018 of PHED DATA

258

-

-

... More
OD196294/2024-2025:Supply of 150mm GI (m) pipe and specials

258

-

-

... More
18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

5

-

-

... More
18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

5

-

-

... More
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

5

-

-

... More
18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

5

-

-

... More
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.

1302

-

-

... More
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.

1302

-

-

... More
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.

2

-

-

... More
100.98.435:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm.

2

-

-

... More
100.60.8.1:Replacing the chocked / damaged 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing mains, up to a length of 5m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / Brass specials viz. brass ferrule, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, safely removing & re-fixing existing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads and as per the directions of the department officers

80

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

67.95

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

21.6

-

-

... More
100.39.5:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 150mm diameter pipe.

20

-

-

... More
OD227204/2024-2025:Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work: 40mm diameter pipe.

56

-

-

... More
Providing FHTC

-

-

-

... More
100.60.1.1.2:Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.

250

-

-

... More
100.60.1.4.2: Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.

250

-

-

... More
100.60.3.1.1:Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers

15000

-

-

... More
100.60.10.4.1:Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.

500

-

-

... More
100.60.12.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.

500

-

-

... More
Supply and installation of motor pump sets and related accessories for improving the water supply

-

-

-

... More
OD196301/2024-2025:Supply, erection, testing and commissioning of new factory assembled KWA approved Centrifugal Split Case Horizontal mounting type Motor pump set with all accessories such as Star Delta Starter, Motor Control panel board, cabling work, cost of earthing, capacitor, valves , connecting to pumping main including suction and delivery pipes etc complete with the following specification. Discharge-31.7 LPS, Total head-78 mtrs. 1) PUMP:-Supply, erection, testing and commissioning of KWA pre-qualified reputed make CF pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete, The duty condition is as follows Discharge-31.7 LPS, Total head-78 mtrs . 2) MOTOR:- Supply, erection, testing and commissioning of KWA pre- qualified reputed make Horizontal foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply, S1 rating ,working voltage 415 V, IP 55 ,4 Pole . The motor shall confirm to IE-3/EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors with non reversing arrangements 3) STARTER - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star Delta Starter for the above motor with over voltage and under voltage protections, Single phasing preventer, Over load relay with motor protection relays, and shall be provided with multifunction digital meter ,indicators etc. 4) MOTOR CONTROL PANEL BOARD:- Supplying floor mounting / Wall mounting type (as per site requirement) CR Sheet Steel fabricated dust and vermin proof common control panel board with following accessories such as MCCB Incomer and MCCB outgoings (Siemens/L&T)of suitable rating so as to operate one outgoing MCCB at a time, interlocking arrangements, copper bus bar distribution, Volt meter and Ammeters with selector switches, phase indicator lamp and other required components and fittings confirming to IE rules and IS specifications suitable for the above motors. The panel board shall have facilities and capacity for connecting 2 Nos. of motors of 50 HP capacity. the panel shall be fitted on a common base frame on suitable foundation with common earth bus. 5) CABLING:- Supplying suitable gauge PVC insulated copper cable suitable size and cable termination materials such as cable socket, cable box for working 75 HP motor as per IE/KSEI/KSEB specifications including capable for bearing starting load for connecting meter board to panel board and panel board to starter and starter to motor 6). EARTHING:- Supply of all materials and Providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc.as per IE standard. 7) CAPACITOR:-Good quality APP type power capacitor of reputed make with ISI mark for the motors to maintain a power factor more than 0.95 which suitable for 50HP motor. 8) VALVES:-Supply of suitable size best quality heavy duty ISI marked 65mm CI double flanged sluice valve of PN 16 Heavy duty 1 No, 80/100 mm CI double flanged NR /reflux valve Heavy duty 1no with suitable pressure rating. Fitting of Valves shall include Proper RCC support especially for Non return valves, in case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9.) PIPE CONNECTION:-Supplying column pipe and delivery pipeline for connecting existing delivery line required length and size as per site conditions. 10.) LABOUR CHARGES:- Erection of pump set, motor with column pipe and all other items supplied, including all labour charges for the erection of pump set, fixing the motor providing cable connections from meter board to panel board, panel board to starters, starter to motor, earthing all electrical equipment's as per CEA regulations and electrical inspectorate specifications; fixing power capacitor and fabricating Y type delivery pipeline and connecting to two numbers pump delivery pipeline if it is necessary including all welding charges etc. and dismantling , for the satisfactory commissioning of the pump set, including all civil works such as providing foundation with foundation bolt in CC 1 :1 1/2 : 3 using 20 mm metal, plastering etc. including cost of cement & steel etc-cleaning and resetting 1 nos existing sluice valve and all civil works such as dismantling the existing unused pump set if it is required and making good the dismantled and all incidental works satisfactorily completion of works etc. complete and taking trial run. The rate is including 2-year standard warranty and 2 year extra warranty ( 5 % added for Additional 2 year warranty)

1

-

-

... More
OD196306/2024-2025:Supply, erection, testing and commissioning of new factory assembled KWA approved Centrifugal Split Case Horizontal mounting type Motor pump set with all accessories such as Star Delta Starter, Motor Control panel board, cabling work, cost of earthing, capacitor, valves , connecting to pumping main including suction and delivery pipes etc complete with the following specification. Discharge-31.7 LPS, Total head-58 mtrs. 1) PUMP:-Supply, erection, testing and commissioning of KWA pre-qualified reputed make CF pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete, The duty condition is as follows Discharge-31.7 LPS, Total head-58 mtrs . 2) MOTOR:- Supply, erection, testing and commissioning of KWA pre- qualified reputed make Horizontal foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply, S1 rating ,working voltage 415 V, IP 55 ,4 Pole . The motor shall confirm to IE-3/EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors with non reversing arrangements 3) STARTER - Supply, erection, testing and commissioning of suitable rating heavy duty fully automatic Star Delta Starter for the above motor with over voltage and under voltage protections, Single phasing preventer, Over load relay with motor protection relays, and shall be provided with multifunction digital meter ,indicators etc. 4) MOTOR CONTROL PANEL BOARD:- Supplying floor mounting / Wall mounting type (as per site requirement) CR Sheet Steel fabricated dust and vermin proof common control panel board with following accessories such as MCCB Incomer and MCCB outgoings (Siemens/L&T)of suitable rating so as to operate one outgoing MCCB at a time, interlocking arrangements, copper bus bar distribution, Volt meter and Ammeters with selector switches, phase indicator lamp and other required components and fittings confirming to IE rules and IS specifications suitable for the above motors. The panel board shall have facilities and capacity for connecting 2 Nos. of motors of 50 HP capacity. the panel shall be fitted on a common base frame on suitable foundation with common earth bus. 5) CABLING:- Supplying suitable gauge PVC insulated copper cable suitable size and cable termination materials such as cable socket, cable box for working 75 HP motor as per IE/KSEI/KSEB specifications including capable for bearing starting load for connecting meter board to panel board and panel board to starter and starter to motor 6). EARTHING:- Supply of all materials and Providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc.as per IE standard. 7) CAPACITOR:-Good quality APP type power capacitor of reputed make with ISI mark for the motors to maintain a power factor more than 0.95 which suitable for 35 HP motor. 8) VALVES:-Supply of suitable size best quality heavy duty ISI marked 65mm CI double flanged sluice valve of PN 16 Heavy duty 1 No, 80/100 mm CI double flanged NR /reflux valve Heavy duty 1no with suitable pressure rating. Fitting of Valves shall include Proper RCC support especially for Non return valves, in case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9.) PIPE CONNECTION:-Supplying column pipe and delivery pipeline for connecting existing delivery line required length and size as per site conditions. 10.) LABOUR CHARGES:- Erection of pump set, motor with column pipe and all other items supplied, including all labour charges for the erection of pump set, fixing the motor providing cable connections from meter board to panel board, panel board to starters, starter to motor, earthing all electrical equipment's as per CEA regulations and electrical inspectorate specifications; fixing power capacitor and fabricating Y type delivery pipeline and connecting to two numbers pump delivery pipeline if it is necessary including all welding charges etc. and dismantling , for the satisfactory commissioning of the pump set, including all civil works such as providing foundation with foundation bolt in CC 1 :1 1/2 : 3 using 20 mm metal, plastering etc. including cost of cement & steel etc-cleaning and resetting 1 nos existing sluice valve and all civil works such as dismantling the existing unused pump set if it is required and making good the dismantled and all incidental works satisfactorily completion of works etc. complete and taking trial run. The rate is including 2-year standard warranty and 2 year extra warranty ( 5 % added for Additional 2 year warranty)

1

-

-

... More
OD196305/2024-2025:Charges for the supply and installation of 100 KVAR APFC Panel with APP Capacitors ( combinations of 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR, 15 KVAR, 25 KVAR, 50 KVAR capacitors etc. ) - 7 stage with FN 315 SFU as incomer , suitable rated capacitor duty contactors and MCCBs with front operated handle for each capacitors, relays, measuring CTs, volt meter, ammeter, 1.6 mm CRCA powder coated, treated and compartmentalised single panel enclosure, panel accessories like bus bar, conical bush, hinges, FRP sheets, base frame, 3.5 x 240 sq.mm incomer cable , 2 x 2.5 sq mm UG copper cable , wiring materials , cable tray/Support, Installation of earthing materials etc for getting the Power factor unity.

1

-

-

... More
OD196304/2024-2025:Supply , installation testing and commissioning of Common Change over cum Starter panel with all front operated handles of fully compartmentalised fan cooled foot mounted 1.6 mm CRCA duly powder coated with common base frame and earthing. The panel shall consist of 1). A change over panel to operate one motor at a time with 400 A 4 pole COS as incomer , 400A SFU with 400 A Semi conductor fuse as Out feeder 1 connected to the 125HP Soft starter, 400A SFU with 315 A Semi conductor fuse as Out feeder -2 connected to the 200HP Soft Starter. 2). 2 Nos Digital thyristor operated type Soft starters suitable for 125 HP and 200 HP Motors working on 415V 3 phase 50Hz supply and shall be provided with over voltage and under voltage ,Over load, Earth fault, Locked rotor, Single phasing, Current unbalance, Phase sequence reversal, Under current, Short circuit, and Dry run protections and Motor protection relay, Indicating lamps ,Multi function meters etc and shall be provided with Main and Bypass contactors and shall conform to CEA regulations and code of practice etc complete. 3.) 2 sets of Capacitors controlled through Capacitor duty Contactors with SFUs/MCCBs of suitable rating so as to operate along with each motor (35KVAr for 125 HP Motor and 50KVAr for 200 HP Motor). The panel shall be provided with proper ventilation and cooling fans and should have common dual CU earth bus . Bus bars of adequate current carrying capacity anticipating running of both motors at a time shall be provided.

1

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

9

-

-

... More
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.

1

-

-

... More
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.

2

-

-

... More
100.31.1.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class I.

1

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

90

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

60

-

-

... More
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)

1.58

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

0.43

-

-

... More
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

11.1

-

-

... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

0.36

-

-

... More
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

3.6

-

-

... More
5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars

121.1

-

-

... More
100.98.494:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 100mm.

1

-

-

... More
100.98.496:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 150mm.

2

-

-

... More
100.98.498:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 250mm.

1

-

-

... More
100.98.499:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 300mm.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.