Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date14 Aug 2024
Closing Date30 Aug 2024
Tender Amount₹ 66,60,222 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

58.35

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

25.01

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

42.53

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11.09

-

-

... More
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

0.68

-

-

... More
5.49:Constructing cast-in situ RCC diaphragm wall by providing and laying machine batched, machine mixed, self compacting, ready mix reinforced cement concrete, tramie controlled, of M 30 grade using minimum 400 kg. cement per cum of concrete including providing and mixing required admixtures in recommended proportions as per IS : 9103, as approved by the Engineer-in-charge, for achieving 150- 200mm slump, for diaphragm wall having thickness as per approved structural design not exceeding 600 mm, in pannels of required depth and lengths as per approved drawing, including constructing necessary guide walls as required and as specified including boring in all kinds of soils and rocks, including working in or under water and / or liquid mud, in foul conditions and pumping or bailing out of water and removing slush, including disposal of earth/ rock / slush etc. for all leads and all lifts, including preparing, providing and re-circulating bentonite slurry in the trench as and when required for all depths, including agitating bentonite slurry during trenching etc., providing and fixing stop ends or form tubes, upto the required depth of diaphragm wall including extracting the same after casting, including chipping off the bentonite adulterated concrete or unsound concrete up to the cut off level for obtaining the sound concrete, dressing undulations on the exposed face of diaphragm wall after excavation by chipping / chiseling etc. including filling the depression/ cavities with sound concrete etc. complete and as directed by the Engineer-in-charge, including providing recess for bearing plates and fixing insert boxes for inclined rock anchors etc. complete as per the specifications and approved design and as directed by the Engineer-in- charge, .but excluding the cost of reinforcement and inserts. (rates include cost of all inputs of labour, material and T & P, cost of handling, lifting & placing in position the reinforcement cage in the trench, including the additional cost of welding the reinforcement bars etc. involved in the work and all other incidental expenditure for completing the work as directed by the Engineer-in-charge), However, the actual area of the diaphragm wall, correct to two places of decimal, from design bottom level to the design cut off level (including portion anchored in the rock upto the design bottom level) only shall be measured for payment. Excess/less cement used for design mix including the extra cement required for under water concreting is payable / recoverable separately.

17.3

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

5.76

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

55.68

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

33.86

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1620

-

-

... More
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

5.26

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

900

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

3

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

119.63

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

46.08

-

-

... More
OD282174/2023-2024:Providing and fixing in position Stainless steel Grade 304 Plate 1.0 mm thick as per design for construction joints.200 mm wide

26.4

-

-

... More
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

90

-

-

... More
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

600

-

-

... More
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

16.2

-

-

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

74.18

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

116

-

-

... More
4.12:Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

537.25

-

-

... More
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

120.24

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

39.25

-

-

... More
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.

3

-

-

... More
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.

3

-

-

... More
OD282175/2023-2024:Supplying and providing S.C.I. S&S, Slotted Cowl (Terminal Guard) 100 mm Vent Cowl

3

-

-

... More
OD283006/2023-2024:Supplying a Mechanical flowmeter of Waltman type conforming ISO 4064 Class B of ARAD/ZENNER/REYCHEM RPG/ITRON make and the flow meter shall be tested and certified by FCRI - Palakkad.

3

-

-

... More
18.60.1:Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

3

-

-

... More
18.61.1:Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :80 mm dia

3

-

-

... More
OD282178/2023-2024:Fabricating, supplying and fixing water level indicator for Tank/sump 3.0m long using 30x30x5 mm MS angle framework, graduations are marked on hylam sheet using weather proof stickers, moving MS plate indicator with reflective stickers, counter weight ball in perforated PVC pipe 140mm size connected with plastic twine running through brass pulley and all arrangements are enclosed in casing pipe etc complete

3

-

-

... More
Appendix B -Supplying of storage tank and valve for booster

-

-

-

... More
100.98.428:Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 80mm.

3

-

-

... More
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.

3

-

-

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

40000

-

-

... More
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1440

-

-

... More
12.1.2:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2

216

-

-

... More
Appendix C -Supplying of GI pipe and specials

-

-

-

... More
OD282186/2023-2024:Supply of 80mm GI Pipe medium including cost of specials

1200

-

-

... More
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.

3

-

-

... More
100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.

3

-

-

... More
100.98.441:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 40mm.

3

-

-

... More
Appendix D -Laying of pumping main for booster & Supply of Pump

-

-

-

... More
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

45

-

-

... More
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.

400

-

-

... More
OD282180/2023-2024:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.<br>Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) for road work

18.75

-

-

... More
OD282181/2023-2024:Dismantling manually / by mechanical means and disposal of material within 50 meters lead as per direction of Engineer -in-Charge: Bituminous road

240

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

100

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

400

-

-

... More
100.12.8:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.

1200

-

-

... More
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.

187.5

-

-

... More
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.

3

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

2.25

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

60

-

-

... More
OD282182/2023-2024:Supplying and fixing 150mm CI surface box embedded with RCC slab of size 0.6x0.6x0.15 and 200mm PVC pipe 10Kg/cm2 pipe acting as protection tube with including all cost of conveyance, labour charges etc. Complete.

6

-

-

... More
OD298900/2023-2024:Supply and fixing submersible pump set including 2 years warranty<br>(Discharge of upto 0.50Lps, Speed upto 1500RPM Total Head Upto 150m )Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 0.5Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD298901/2023-2024:Supply and fixing of a STANDBY submersible pump set including 2 years warranty<br>( 0.5Lps, Speed upto 1500RPM Total Head Upto 150m) Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 0.5Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD298847/2023-2024:Supply and fixing of a submersible pump set including 2 years warranty<br> ( 1.50Lps, Speed upto 1500RPM Total Head Upto 150m)Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 1.50Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD298844/2023-2024:Supply and fixing of a STANDBY submersible pump set including 2 years warranty<br> ( 1.50Lps, Speed upto 1500RPM Total Head Upto 150m)Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 1.50Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD298881/2023-2024:Supply and fixing submersible pump set including 2 years warranty<br>(Discharge of upto 1.00Lps, Speed upto 1500RPM Total Head Upto 150m) Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 1.00Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD298890/2023-2024:Supply and fixing of a STANDBY submersible pump set including 2 years warranty<br>Discharge of upto 1.00Lps, Speed upto 1500RPM Total Head Upto 150m. Supply, erection, testing and commissioning of KWA pre-qualified reputed make submersible pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc suitable for coupling the pump and motor above the base plate, including providing suitable concrete foundation including cost of cement sand metal and steel. The duty condition is as follows. Discharge of upto 1.00Lps, Speed upto 1500RPM Total Head Upto 150m Suction Head 0m Length of suction pipe 0m size of pumping main 80mm dia GI pipe. Length Average of 900m Alternatively the inlet & outlet levels, type, size & length of pumping main etc. can be given. Supply, erection, testing and commissioning of suitable rating starter with automation suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contractor and bypass contractor as per IE rules and code of practice etc. Panel board(suitable for operating One pump set) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going(the MCCBs are interlocking with each other suitably ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. (Specification may be modified according to no of motors working at a time) Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from transformer panel board to starter and from starter to motor considering energy conservation. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valved shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m for each pump, suitable for the above pumpset and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes and specials shall be provided Additional two year warranty.

5

-

-

... More
OD282184/2023-2024: Supply erection testing and commissioning of Advanced wireless fully automatic water level controller with sump to overhead tank / Mobile operated GSM based module for operation of starters and controllers from anywhere using mobile phone .outdoor transmitter powered by solar panel with rechargeable Li-ion battery - suitable for 3 phase 5 - 10 HP motor starter, with design tested to perform reliably even in extreme environmental conditions, suitable for single phase and three phase installations, fully automatic ON/OFF with level sensors, communication with IVRS in local languages, 4 user can control the operation, power fail and feed back SMS in regional languages, four different "time of day" can be set in a day for pump operation, controls daily operations of a pump for pre-defined periods and ease of operation with advanced facilities such as auto switch off while dry run with in fraction of seconds, low voltage preventer, phase change preventer, low voltage cut off, online monitoring system etc of reputed make.

6

-

-

... More
OD282185/2023-2024:Works related to Panel Board Standardization-Installation charges and setting the Starter and GSM Module,connecting the cable, crimping socket with cable etc as per the direction of departmental officers

3

-

-

... More
Appendix E -Road reformation-Panchayath roads

-

-

-

... More
3.6:Excavation in Marshy Soil Excavation for roadway in marshy soil with hydraulic excavator 0.9 cum bucket capacity including cutting and loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 m, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.6.

50

-

-

... More
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material

120

-

-

... More
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

135

-

-

... More
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

300

-

-

... More
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.

420

-

-

... More
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)

600

-

-

... More
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)

600

-

-

... More
75.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)

108

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.