Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date22 Jan 2024
Closing DateCancelled
Tender Amount₹ 24,06,72,189 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100.52.S.1:Sub Data for providing Earth filled cement bags including cutting of the Earth, filling, conveying and placing in position.

42630

-

-

... More
100.52.S.3:Sub Data for Supplying, conveying and covering using best quality polythene sheet on bund to protect bund from seasonal changes.

2550

-

-

... More
100.52.S.4:Sub Data for Conveying and providing bamboo poles for reinforcing the temporary bund including the cost materials and labour charges etc. complete.

472.5

-

-

... More
100.52.S.2:Sub Data for Filling with contractor's own earth (excluding rock) in the core portion of the earthen bund by consolidating each deposited layer by ramming and watering, as per direction of the departmental officers.

2625

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

2684.52

-

-

... More
100.3.7.1:Earthwork in open well excavation (above water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.

241.9

-

-

... More
100.3.7.2:Earthwork in open well excavation (above water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.0m including neat banking.

239.5

-

-

... More
100.4.8:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 4.5m (3.0m to4.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

347.5

-

-

... More
100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

347.5

-

-

... More
OD224778/2023-2024:Granite rock blasting in well, measured in solids, including collecting and stacking spoil for measurement with in the initial lead of 50 m and lift upto 7.5 m (6 m to 7.5m) but excluding bailing out of water and including providing protection by earthfilled cement bag(300 nos of earthfilled cement bag/10 cum blasting) to avoid damages to the nearby structure

347.5

-

-

... More
OD224779/2023-2024:Granite rock blasting in well, measured in solids, including collecting and stacking spoil for measurement with in the initial lead of 50 m and lift upto 9 m (7.5m to 9 m) but excluding bailing out of water and including providing protection by earthfilled cement bag(300 nos of earthfilled cement bag/10 cum blasting) to avoid damages to the nearby structure.

347.5

-

-

... More
OD224780/2023-2024:Granite rock blasting in well, measured in solids, including collecting and stacking spoil for measurement with in the initial lead of 50 m and lift upto 10.5 (9 m to 10.5 m) but excluding bailing out of water and including providing protection by earthfilled cement bag(300 nos of earthfilled cement bag/10 cum blasting) to avoid damages to the nearby structure.

239.5

-

-

... More
OD224781/2023-2024:Granite rock blasting in well, measured in solids, including collecting and stacking spoil for measurement with in the initial lead of 50 m and lift upto 12 m (10.5 m to 12 m) but excluding bailing out of water and including providing protection by earthfilled cement bag(300 nos of earthfilled cement bag/10 cum blasting) to avoid damages to the nearby structure.

199

-

-

... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

16778.25

-

-

... More
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

16.9

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

9.35

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

2.81

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

34.67

-

-

... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining

1163.05

-

-

... More
20.6.3.1:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Group of two or more piles upto 50 tonne capacityInitial test

1

-

-

... More
20.2.2:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).400 mm dia piles

250

-

-

... More
20.6.1.2:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile upto 50 tonne capacityRoutine test

1

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

519.42

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

262.06

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

486.34

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

624.15

-

-

... More
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

715.9

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

300.3

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

214.25

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

703.87

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

67832.16

-

-

... More
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

72.93

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

265.78

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

2723.51

-

-

... More
10.26.2:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.E.R.W. tubes

1054.19

-

-

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1205.02

-

-

... More
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

7.35

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

72

-

-

... More
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )

14

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

8

-

-

... More
9.97.1:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

4

-

-

... More
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop

2

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

19.25

-

-

... More
10.9:Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

2.25

-

-

... More
10.8.1:Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

19.25

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

3.75

-

-

... More
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

7.2

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

75.38

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

500

-

-

... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

115.59

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

2555.99

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

4625

-

-

... More
100.31.1.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class I.

6

-

-

... More
OD224782/2023-2024:supply of 500 mm DI D/F pipe

90

-

-

... More
18.30.11:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:500 mm diameter pipe

30

-

-

... More
OD224783/2023-2024:Supplying and fixing 500 mm DI wall casting pipe

10

-

-

... More
100.98.479:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 500mm.

5

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

13.13

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

3

-

-

... More
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
17.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern

1

-

-

... More
17.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

1

-

-

... More
17.28.1.1:Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe32 mm dia

1

-

-

... More
17.32.1:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia

1

-

-

... More
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters

1.58

-

-

... More
17.34.1:Providing and fixing toilet paper holder:C.P. brass

1

-

-

... More
17.35.1.1:Providing and fixing soil, waste and vent pipes: 100 mm diaSand cast iron S & S pipe as per IS : 1729

3

-

-

... More
18.15.2:Providing and fixing brass bib cock of approved quality :20 mm nominal bore

1

-

-

... More
50.18.8.2.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2

25

-

-

... More
100.52.S.5:Sub Data for Dismantling the sand / earth filled cement bag from the foundation site of bund, apron on both sides, counter wall and removing the sand/earth from the bag and disposing the damaged cement bags properly as per the direction of the department officers including all cost of labour charges etc complete.

2016

-

-

... More
OD224784/2023-2024:Rate for the structural design and detailing of intake well and vetting from WASCON

1

-

-

... More
OD224785/2023-2024:Providing E.O.T. gantry crane arrangement of 5 Tone capacity. as per IS specification.it can move circularly and east -west and north-south.direction

1

-

-

... More
OD224786/2023-2024:For extending spindle of 500 mm CI sluice valve from the well to the floor level as to operate the valve at the floor level

5

-

-

... More
APPENDIX B - SUPPLY AND INSTALLATION OF TRANSFORMER AND OTHER ELECTRIFICATION WORKS

-

-

-

... More
OD224721/2023-2024:Supply Erection and commissioning of 1000 KVA USS Transformer (Indoor type ) at Intake well site Kaduvathodu. Supply ,errection ,testing and commissioning of of 11KV/3.3KV,1000kVA<br>,50Hz,3phase , Vector Dyn 11 Resin Cast Indoor type copper<br>wound Transformer(IP 23) on load tap changer with RTCC &AVR panel tapping +5% to -5% in<br>steps of 2.5% with winding temperature scanner and hooter , LV<br>side provision for Bus Duct and HV side connected with 11KV VCB panel & the LV compartment which houses ACB. . All components are to be housed in an enclosure which protects the equipment against environmental hazards & unauthorized access . The electrical equipments are to be cooled by natural ventilation including all cost and erection charge. Supply errection ,testing and commissioning of Indoor type 11kV, 630A, 26.3kA<br>for 3 sec Horizontal Draw out VCB fitted with Manual/Motor<br>operated spring charging mechanism with 230V AC motor and<br>motor control switch, shunt trip coil of 24V DC, closing coil of<br>24V DC, Auxiliary Contact 6NO + 6NC,Mechanical ON/OFF<br>indicator, mechanical operation counter, Anti pumping feature,overcurrent and earth fault relay, protection CT, (--/5 A, 5P10,<br>15VA , 11kV/110V, Cl-0.2, 25VA PT Instantaneous IDMT relay<br>with Microprocessor based 3O/C + and 1EF Protection relay, Strip<br>Heater with thermostat, Power pack 230V AC-24 V DC<br>emergency OFF push button, ammeter & voltmeter with selector<br>switch HT metering (3nos CT & 1no PT Unit) FOR KSEB

1

-

-

... More
OD224722/2023-2024:Supply, Installation, testing and commissioning of Transformer 63 kVA , 11KV/440V, 50c/s, Cast resin dry type, vector group DYN-11, copper wound indoor type, with cable box at the 11KV side and LT side, OFF load tap at the 11KV side, H.V.Compartment which houses Vacuum Circuit Breaker (VCB) or Load Break Switch (LBS), the transformer compartment which houses dr y type /oil cooled transformers & the LV compartment which houses ACB, MCCB, SFU etc. . All components are to be housed in an enclosure which protects the equipment against environmental hazards & unauthorized access . The electrical equipments are to be cooled by natural ventilation including all cost and erection charge

1

-

-

... More
OD258380/2023-2024:Statutory Approval - Obtaining statutory approval from Eletrical Inspectorate including preparation of drawings, obtaining approval for the drawings arranging inspection of the installations and obtaining safety certificate etc.after completion of the work.The necessary statutory fees if any payable to the Electrical Inspectorate/ KSEB will be paid by KWA" .(Note: Scheme approval from theElectrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials will be released only on production of scheme approval.)

1

-

-

... More
OD258381/2023-2024:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards

1

-

-

... More
OD258382/2023-2024:Supply, erection, testing and commissioning of indoor type CT and PT 3 phase 4 wire system 3 phase PT 11KV/110Volt,0.2s,25VAIL 12/28/75KV as per IS3156.CT Ratio 40/5A or as per KSEBL specification on contract demand Burden 10VA,0.2S accuracy class,IL12/25/75 KV as per IS2705 & KSEBL specification,STR 13.1KA/s

1

-

-

... More
OD258383/2023-2024:Supply,erection, testing and commissioning of TOD meter 3phase, 4 wire, HT CT/PT operated, Uni-directional, accuracy class 0.2S for both Active and Reactive energy, - /5A/-/1A, HT static tri vector meter with TOD register,DLMS compliant & AMR compatible with optical and RS232 port, having ISI Marking,suitable for measurement of active energy kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5Hz to 52.5 Hz in balanced as well as unbalanced load conditions in accordance with IS: 15959 / 2011 with its latest amendments.

1

-

-

... More
OD258384/2023-2024:Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, 26.3KA,3sec totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type vacuum circuit breaker fitted with manual/motor operated spring charge mechanism with 230V AC motor and motor control switch,shunt trip coil of 24 volt DC auxiliary contact 6NO+6NC, Mechanical ON/OFF indicator, Mechanical operation counter, Anti pumping feature, Automatic safety shutters and push button etc, four panel system (1 no. VCB as incomer and 2 Nos. VCBs as outgoings) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments, MC61A numerical protective relays etc. draw out type resin cast 11/0.1 KV & PT with controlling fuses for both side .2 class Dual core CT , LED panel lamps , panel heaters etc complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections.Also the panel should have metering facilities as per kseb specifications The cost of control cables both internal and external shall be included in the cost of HT panel, 11KV Switchgear (Indoor). The incomer VCB shall be provided with tariffTOD meter with 3 nos 60/ 5 Amps class 0.2S 15 VA CT and 3 nos 11KV / 110 Volt class 0.2PT etc including sealing and locking arrangement all civil workssuch as transportation , handling making suitable foundations etc charges for testing calibrationby TMR charges for erection and commissioning is included complete.

1

-

-

... More
OD258385/2023-2024:Supply, erection, testing and commissioning of 3.3KV, 400 A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type panel board comprising of 1Nos. Vacuum Circuit Breaker as incomer 2nos. Vacuum Circuit breakers(3 Panel system). The incomer switchgears, & outgoing switch gears should be of draw out type trip free VCBs with suitable overload and short circuit protection releases, suitable UV and shunt releases for probable integration to control wiring including PLC unit and its auxiliary systems for remote monitoring and operation and provision for future up gradation to SCADA, suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, MC 61A high set numerical protective relays, . resin cast,3.3 KV /110/230V PT with control fuse for each incomers 0.2 class dual core CT LED panel indicates digital multi function meters,with minimum features to read V, A, Hz, PF, THD % inall the out going feeders and incomers including suitable CT/PT and protection arrangements ,panel, heaters with timer/RTD based automatic operation , suitable SMF battery and battery charger arrangements etc.. complete as approved by Kerala Electrical Inspectorate and relevant standards. armored multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel, 3.3KV Switch gear.

1

-

-

... More
OD258386/2023-2024:Neutral Grounding Resistor, Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR

1

-

-

... More
OD258387/2023-2024:Lighting Distribution board (LDB), Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system

1

-

-

... More
OD258388/2023-2024:Supply of ISI marked 3 core 300 Sq.mm, 11 kV armoured XLPE AL Cable

120

-

-

... More
OD258389/2023-2024:Supply of ISI marked 3.5 x 50 sqmm 440 v aluminium cable, 20 mtr, 4c x 2.5 sqmm copper control cable 60 mtr, 3.5 35 sqmm al armoured cable - 25 mtr,4c x 16 sqmm al armoured cable 40 mtr and its terminations

1

-

-

... More
OD258390/2023-2024:Supply and laying,testing and commissioning of following size/suitable size XLPE insulated PVC sheathed Armoured Alluminium conductor cable(3.3kv grade) clamped on wall/ceiling with clamps partly laid in trench and partly in cable tray,3core 240sq.mm,3.3kv grade XLPE Alluminium UG cable laying from transformer LV side to 3.3kv pannel (incomming side)

40

-

-

... More
OD258391/2023-2024:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3 core 240 Sq.mm.3.3kv,XLPE AL Cable(Indoor)

2

-

-

... More
OD258392/2023-2024:Supply of all materials and providing end termination of the following size/suitable size heat shrinkable PVC/XLPE insulated, sheathed armoured Aluminium conductor cable 11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 300 Sq.mm.11kv,XLPE AL conductor shrinking type Cable kit (Indoor)

3

-

-

... More
OD258393/2023-2024:Supply and laying of 11 kV HT cable of size - 3x150sq.mm XLPE Cable.

20

-

-

... More
OD258394/2023-2024:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminum conductor cable of 11 KV grade as required: 3x150 sqmm indoor end termination - indoor

2

-

-

... More
OD258395/2023-2024:Supply of all meterials and providing end termination kit (Out door type) of the fallowing size heat shrinkable 3x 300sq.mm PVC/XLPE armoured Alluminium conducor cable(11kv grade) for receiving power connection from KSEB 11 KV structure

1

-

-

... More
OD258397/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x5mm copper strips.

1

-

-

... More
OD258405/2023-2024:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.

550

-

-

... More
OD258410/2023-2024:Earthing with G.I. earth plate1200 mm X1200 mm X 12 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. The earthing station should confirm to IS 3043/87. (All civil works shall be done by the contractor)

8

-

-

... More
OD258411/2023-2024:Supply and installation of MSB panel board with 100A - 1 nos mccb incomer and 63A 4p MCCB -4nos,EFR,neutral ct, indications,MFM with RS485 1 nos, voltmeter 1 nos, suitable current transformer etc

1

-

-

... More
OD258396/2023-2024:Plant automation using PLC system and scada including valves with actuator, Pressure gauge with rs 485 output,electromagnetic flow meter with RS 485 communication and display and other items required for automation of plant and display of relevant parameters

1

-

-

... More
OD258398/2023-2024:Charges for testing EFR,CT, PT,TOD meter and obtaining certificate from electrical inspectorate including statutory and sundry charges

1

-

-

... More
OD258399/2023-2024:Supply of following protection items, fire extinguisher 3 nos, fire bucket 4 nos, 3.3 kv rubber mat 15 sqm, 11kv grade rubber mat 30 sqm,1.1kv grade rubber mat 15 sqm,emergency push button 1 nos, shock treatment chart 1nos, HT hand gloves 1 no, danger boards 5 nos, first aid box 1 nos

1

-

-

... More
OD258400/2023-2024:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top &;lt;br & gt; surface finished neat

1

-

-

... More
OD258402/2023-2024:Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings)

29

-

-

... More
OD258403/2023-2024:Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

100

-

-

... More
OD258404/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required - Group.B

200

-

-

... More
OD258406/2023-2024:Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required including cost and conveyance of ceiling fan.

4

-

-

... More
OD258407/2023-2024:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. - 18/20/24 W four feet LED tube light

15

-

-

... More
OD258412/2023-2024:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. - 9 /12 W LED bulb

10

-

-

... More
OD224742/2023-2024:Arrangements of soil resistivity certificate

1

-

-

... More
APPENDIX C -SUPPLY, INSTALLATION AND COMMISSIONING OF VT RAW WATER PUMPSET AT INTAKE PUMPHOUSE KADUVATHODU

-

-

-

... More
OD224749/2023-2024: Supply, erection, testing, trial running and commissioning of following 1.Pump - best quality ISI marked electrically driven water lubricated Vertical turbine pump set with bronze impeller with M.S ERW column pipe of suitable diameter and SS 316 shaft with suitable type base plate, foundation, nuts and bolts including providing suitable concrete foundation including cost of cement, sand and metal etc complete. The duty conditions of pumpset are:- 220 lps (Including water loss due to backwash etc), Total head-149m Two pumpsets running at a time in parallel with one standby .Suitable delivery size so as to suit the pumping main. 2. Motor- Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz Ac supply, working voltage 415V/3300 V(select suitable), 1500rpm. The motor shall confirm to Latest IE standards, including providing suitable concrete foundation, including cost of materials etc. complete for 3300 V motors digital motor protection. Relay shall be included in starter as per present IE rules,Flexible coupling shall be used for coupling of pumps and motors 3. Starter. Supply erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starter to be used) . Here soft starter to be provided. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventor, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc complete 4. Panel board - Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity motor protection MCCB as incomer and and No of suitable capacity MCCB as outgoing providing suitable size Aluminium bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no. volt meter with selector switch, 1 no. Ammeter with selector switch for measuring current in each phase etc. complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work - Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation for a total length of 10 M. 6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Capacitor should be connected to external contactor, and the capacitor shall confirm to IS 2834 8.Valves and Pressure gauges – Supply, Erection and commissioning of suitable size best quality heavy duty ISI marked CI double flanged Sluice Valve electrical actuator (capable of operating in Fully, Semiautomatic modes and also in manual mode), Non Return Valve and Pressure Gauges with suitable Pressure rating. Fitting of valves shall include proper RCC support. In case of positive suction pipes set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connection - Supply and fitting of suitable size best quality MS pipe of shell thickness not less than 10 mm for a total of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc complete and connecting the delivery side of thr pump with the valves and suitable specials to connect the pumping main. If the dia of suction pipe is above 80 mm CI pipes and specials shall be provided. Efficiency of pumpset shall not be less than 70%. The guarantee period is minimum two years with full replacement of above mentioned units . As per the order no. 9710/ae 15/2021/kwa dtd 8-2-2023.

3

-

-

... More
OD224750/2023-2024:Supplying an 600mm electromagnetic flow meter confirming to protection level of IP -68 for flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter shall have the housing (flow sensor) to be made of SS304/carbon steel with anti corossive protectection and inside liner to be made up of Hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data accquisition and transfer with provision for wireless transfer through GSM . The manufacturer should have the calibration stds as per ISO 17025 and the product shall have sufficient warranty provisions..Test certificate from FCRI palakkad.

1

-

-

... More
OD224751/2023-2024:Supply,Design, fabrication,erection , testing and commissioning of following Cubicle type, fully compartmentalised Main Switchboards dust tight and vermin proof, fabricated out of 16 SWG CRCA sheet, chemically treated and painted with 2 coats of primer and two coats of enamel paint of approved shade. The Switchboards should have a Set of suitably rated TPN Aluminium busbars with the specified current and fault level, Insulated with heat shrinkable, color coded PVC Sleeves and type busbar supports. The design should be as per the standards of the State Electrical 'Inspectorate 'fabricated out of 16SWG CRCA sheet. Bottom cable entry for outgoing feeders and top busbar trunking facility for incomers. ( Market rate)<br> Busbars:<br>400A Aluminium Busbarwith suitable ratings of SFU as incommer and out going switches provided with over current and earth fault protection<br>Incomer: 400A TPN Isolator -1no. <br>Meters & Indicators<br>1No. 0-500V Voltmeter along with voltmeter Selector switch<br>3Nos. 2A Control fuses. - 1set.<br>Red, Yellow and Blue Indication Lamps 3nos, 2A Control fuses - 3set<br>Outgoings:<br>200A TPN SDFU with HRC fuse - 1No.<br>160A TPN SDFU with HRC fuse - 4Nos.<br>100A TPN SDFU with HRC fuse - 1No.<br>63A 3P MCB - 2Nos.<br>32A 3P MCB - 2Nos.

1

-

-

... More
OD224752/2023-2024:Supply, laying, testing and commissioning of 3.5core 150 Sq.mm XLPE insulated, sheathed armored Aluminum conductor cable (3300 Volts grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.

320

-

-

... More
OD224753/2023-2024:Supplying and fixing 32Amps,TPN,6 way distribution tap off box with ISI markes HRC fuses

1

-

-

... More
OD224754/2023-2024:Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed Medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

10

-

-

... More
OD224755/2023-2024:Supplying, fabricating and fitting meter box as per KSEB rules fxing the meter and fuse unit of KSEB

1

-

-

... More
OD224756/2023-2024:Supply, Installation, testing and commissioning of 20 Watts LED outdoor roof lantern of reputed brand ( Bajaj, GE, Havels, Osram, Philips, Surya, Syska) directly on ceiling or wall including connection with 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. as required.

1

-

-

... More
OD224757/2023-2024:Supply, Installation, testing and commissioning of 12Watts LED Bulb of reputed brand ( Bajaj, GE, Havels, Osram, Philips, Surya, Syska) directly on ceiling or wall including connection with 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. as required.

5

-

-

... More
OD224758/2023-2024:Supply, Installation, testing and commissioning of 1200mm ceiling fan of reputed brand ( Crompton greeves,bajaj,Usha,Havels, Khaitan) with best quality stepped electronic regulator including charges for wiring the down rods of standard length(upto 30cm) with 1.5 Sq.mm FR PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

2

-

-

... More
OD224759/2023-2024:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin/ 5/6 amps modular socket outlet and 5/6amps modular switch in the existing modular box by increasing the size of the box plate etc as required

4

-

-

... More
OD224760/2023-2024:Wiring for circuit or sub main wiring along with earth wire with following size FRLS PVC insulated copper conductor single core cable in surface/recessed Medium class PVC conduit etc. as required. 2 x 2.5 sq. mm +1 x 2.5 sq. mm earth wire

60

-

-

... More
100.37.21.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

50

-

-

... More
100.37.21.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.

50

-

-

... More
100.37.21.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

50

-

-

... More
100.37.21.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

50

-

-

... More
100.37.21.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

50

-

-

... More
OD224761/2023-2024:Supply, conveyance and fixing of DN600, PN1.6 or above dual plate NR valve as per the direction of departmental officers etc. complete

2

-

-

... More
OD224762/2023-2024:Providing flanged joints to double flanged MS pipes and specials, including testing of joints: 600mm Diameter Pipe.

25

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

87

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

67.6

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6960

-

-

... More
APPENDIX D - RAW WATER PUMPING MAIN TO WTP AT CHAYALODU AND CLEAR WATER PUMPING MAIN TO MALANADA OHSR

-

-

-

... More
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.

8425

-

-

... More
15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

39.38

-

-

... More
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

100.43

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

9045.23

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

7122.51

-

-

... More
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.

5471.84

-

-

... More
100.1.13:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.

1757.18

-

-

... More
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

1807.25

-

-

... More
100.2.8:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

66.69

-

-

... More
100.1.14:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock where Blasting is Prohibited.

66.69

-

-

... More
100.4.1:Excavating in hard rock for trenches by blasting for laying pipes and stacking useful materials for measurements and disposing unserviceable materials within the initial lead of 50m and lift up to 1.50m (depth from 0.0m to 1.50m) and providing protection by earth filled cement bags during blasting to avoid damages to nearby structures (200 Nos. of earth filled cement bags for 10m3 of blasting)

200.06

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

48.31

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

7952

-

-

... More
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m

840

-

-

... More
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m

18

-

-

... More
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.

6100

-

-

... More
100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.

6600

-

-

... More
OD224718/2023-2024:Labour for cutting C.I. pipe with steel saw.600 mm diameter D.I/C.I. pipe

50

-

-

... More
OD224719/2023-2024:Labour for cutting C.I. pipe with steel saw.200 mm diameter DI/C.I. pipe

50

-

-

... More
100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.

6600

-

-

... More
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.

6100

-

-

... More
100.35.10:Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA

6100

-

-

... More
100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA

6600

-

-

... More
18.73.2:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :150 mm dia Ductile Iron Double Flanged

36

-

-

... More
18.73.6:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :350 mm dia Ductile Iron Double Flanged

36

-

-

... More
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe

15

-

-

... More
18.30.4:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:150 mm diameter pipe

15

-

-

... More
100.32.6:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 150mm Double Acting Air Valve.

12

-

-

... More
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.

12

-

-

... More
100.98.450:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.

12

-

-

... More
100.98.452:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 150mm.

12

-

-

... More
100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.

4

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

1

-

-

... More
100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm.

3

-

-

... More
100.98.488:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 350mm.

4

-

-

... More
100.31.2.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class II.

4

-

-

... More
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.

3

-

-

... More
100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II.

3

-

-

... More
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.

1

-

-

... More
18.70.10:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes

1150

-

-

... More
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia

39.6

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

265.64

-

-

... More
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes

1225

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

553.21

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1929.6

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

27660.7

-

-

... More
100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

80

-

-

... More
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

80

-

-

... More
100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

240

-

-

... More
100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

240

-

-

... More
100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

240

-

-

... More
100.37.21.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

80

-

-

... More
100.37.21.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.

80

-

-

... More
100.37.21.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

240

-

-

... More
OD224720/2023-2024:Providing flanged joints to double flanged MS pipes and specials, including testing of joints: 600mm Diameter Pipe.

25

-

-

... More
100.37.21.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

240

-

-

... More
100.37.21.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

240

-

-

... More
100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.

5

-

-

... More
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.

5

-

-

... More
16.73:Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete ( Payment for stone to be made separately)

560.17

-

-

... More
OD245619/2023-2024:GIS mapping, Drawings soft copy and hard copy submitted on each bill, and finally submitted the full data.GIS mapping coordinates of regular intervals regarding sizes and locations of pipes, valves, and other all attributes in order to proper asset management and future servicing of the system and in order to upload in Google map.Drawings soft copy and hard copy(4Nos) with final bill .As per the Circular issued by the CE)SR) The GIS map soft copy and hard copy to be submitted to Jalabhavan (GIS wing) through the concerned EE in order to upload to the web site

1

-

-

... More
Road restoration work - Panchayath Road

-

-

-

... More
4.1.A.2:Granular Sub-base with Well Graded Material (Table 400.1)(A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material

529.43

-

-

... More
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

529.43

-

-

... More
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

3529.5

-

-

... More
5.2.1a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

3529.5

-

-

... More
5.11.1.A.2a:Mix Seal Surfacing - Manual Means - Type A - Bitumen S-65 Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 By Manual Means :- Type A (II) Bitumen (S-65)

3529.5

-

-

... More
PANCHAYATH ROAD CONCRETING

-

-

-

... More
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

107.25

-

-

... More
APPENDIX F - CONSTRUCTION OF 7LL OHSR AT MALANADA

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

400

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

767.88

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

511.92

-

-

... More
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns

10.8

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

48.6

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

264.4

-

-

... More
OD224763/2023-2024:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. .All work upto plinth level

141.5

-

-

... More
OD224764/2023-2024:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. .All work above plinth level upto floor V level

302.24

-

-

... More
OD224765/2023-2024:Extra for providing richer mixes at all floor levels. .Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

443.74

-

-

... More
4.12:Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

196.63

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

736.22

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

432.91

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

467.67

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

488.88

-

-

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

82.39

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

14150

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

36268.86

-

-

... More
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

727.09

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

2040.7

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

1809.66

-

-

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

711.5

-

-

... More
OD224766/2023-2024:Providing ventilation arrangement to the tank using 80 mm GI pipe and bend , fixing in the roof slab including painting, net in the open end for entry of flies etc complete as directed.

20

-

-

... More
OD224767/2023-2024:Supply and Fixing of 350mm DI wall casting pipe

1

-

-

... More
OD224768/2023-2024:Supplying and fixing 200 mm DI wall casting pipe

4

-

-

... More
OD224769/2023-2024:Supplying,Conveying and Fixing Water level indicator in the OHSR made of Aluminium with powder coated having marked properly including all accessories etc.

1

-

-

... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

193.05

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

1975

-

-

... More
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.

700

-

-

... More
OD224771/2023-2024:Supply and installation of lightning protection arrangements as per IScode.

1

-

-

... More
OD224772/2023-2024:Supplying and fixing ( including specials) Electro- magnetic flow meter 350mm confirming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit . The flow water meter should have the housing ( flow sensor) to be made of SS 304/ Carbon steel with anti corrosive protection and inside liner to be made up of Hard Rubber or neoprene all conforming to drinking water standards.The flow meter should be coupled with HART data acquisition and transfer, with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and product shall have sufficient warranty provisions.as per KWA circular and test certificate from FCRI palakkd

1

-

-

... More
OD224773/2023-2024:Constructing valve chambers in RCC 1:1.5:3 with inside size 1.00 x 1.00m and wall thickness 15cm, Cover slab 15cm thick , plastering

4

-

-

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

166.42

-

-

... More
18.25.1:Providing and laying S & S C.I standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class):Upto 300 mm dia

5.25

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

4

-

-

... More
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.

3

-

-

... More
100.31.1.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class I.

1

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

2.88

-

-

... More
100.98.461:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.

3

-

-

... More
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.

1

-

-

... More
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe

60

-

-

... More
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe

25

-

-

... More
18.73.3:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :200 mm dia Ductile Iron Double Flanged

65

-

-

... More
18.73.6:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :350 mm dia Ductile Iron Double Flanged

25

-

-

... More
100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA

60

-

-

... More
100.35.5:Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA

25

-

-

... More
OD244750/2023-2024:Charges for preparation of Good For Construction (GFC) drawings (both structural & architectural) through an accredited Structural Engineer/Govt. Accredited Agency after conducting Soil Investigation at OHSR site. The charges include the vetting charges for M/s WASCON, submission of 3 set of minimum A3 size Drawings for vetting by WASCON, soft copy of drawing in AUTOCAD and including any other design consultation charges complete as per direction of Departmental Engineer - In - Charge of the work.

1

-

-

... More
APPENDIX G - CONSTRUCTION OF RCC VALVE CHAMBER

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

228

-

-

... More
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

57.49

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

57.49

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

15.2

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

94.97

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

7597.84

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

30.92

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

399.82

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

104.51

-

-

... More
OD224775/2023-2024:Supplying and fixing C.I man hole cover with frame for manholes:560 mm diameter ( heavy duty) the weight to be not less than 208 kg.

32

-

-

... More
SUPPLY AND INSTALLATION AND COMMISSIONING OF CLEAR WATER PUMPSET AT WTP SITE - TO OHSR AT MALANADA

-

-

-

... More
OD224776/2023-2024:Design, Supply , erection, testing, Trial run and commissioning of CF pump set with the following specification - 1. Pump - Supply, erection, testing and commissioning of KWA pre-qualified reputed make centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable types base plate with coupling, coupling guard, foundation bolts and nuts etc. complete including providing suitable concrete foundation including cost of material etc. complete. as per CEA regulation 2010 and present code of practice for Discharge 27.66lps, Total head- 34.212m, 1500RPM,Suction head - 3.50 m Length of suction pipe - 4.00 m including 1 as stand by including cost of all required protection equipment with an efficiency not less than 70%, Suction head – positive suction, 2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz Ac supply, working voltage 415V/3300 V(select suitable), 1500rpm. The motor shall confirm to Latest IE standards, including providing suitable concrete foundation, including cost of materials etc. complete for 3300 V motors digital motor protection. Relay shall be included in starter as per present IE rules. . Flexible coupling shall be used for coupling of pumps and motors 3. Starter. Supply erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starter to be used) . Here Star Delta starter to be provided. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventor, overload relay with motor protection relay with main contactor and bye pass contactor as per IE rules and code of practice etc complete 4. Panel board - Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity motor protection MCCB as incomer and and No of suitable capacity MCCB as outgoing providing suitable size Aluminium bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 no. volt meter with selector switch ,1 no. Ammeter with selector switch for measuring current in each phase etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work - Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation for a total length of 10 M. 6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Capacitor should be connected to external contactor, and the capacitor shall confirm to IS 2834 8.Valves and Pressure gauges – Supply, Erection and commissioning of suitable size best quality heavy duty ISI marked CI double flanged Sluice Valve electrical actuator (capable of operating in Fully, Semiautomatic modes and also in manual mode), Non Return Valve and Pressure Gauges with suitable Pressure rating. Fitting of valves shall include proper RCC support. In case of positive suction pipes set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connection - Supply and fitting of suitable size best quality MS pipe of shell thickness not less than 10 mm for a total of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc complete and connecting the delivery side of the pump with the valves and suitable specials to connect the pumping main. If the dia of suction pipe is above 80 mm CI pipes and specials shall be provided. Efficiency of pumpset shall not be less than 70 %. The guarantee period is minimum two years with full replacement of above mentioned units . As per the order no. 9710/ae 15/2021/kwa dtd 8-2-2023.

2

-

-

... More
100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

24

-

-

... More
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

12

-

-

... More
100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

24

-

-

... More
100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

24

-

-

... More
100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

24

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

3.26

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

14.56

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

260.64

-

-

... More
OD224777/2023-2024:Supplying an 200mm electromagnetic flow meter confirming to protection level of IP -68 for flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter shall have the housing (flow sensor) to be made of SS304/carbon steel with anti corossive protectection and inside liner to be made up of Hard rubber/ neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data accquisition and transfer with provision for wireless transfer through GSM . The manufacturer should have the calibration stds as per ISO 17025 and the product shall have sufficient warranty provisions..Test certificate from FCRI palakkad

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.