Kerala Water Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 1,00,000Document Cost
₹ 9,759Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KWA_641770_1Tender No
E-Tender No 264/2023-24/SE/PHC/CHNTender Authority
Kerala Water Authority ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General conditions of E Tendering Process
BOQ Items
100.98.486:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 250mm.
1
-
-
OD264076/2022-2023:Ductile Iron K-12 specials suitable for mechanical jointing up to 600 mm dia
20.35
-
-
Construction of 5LL capacity GLSR and pump house - Working Charges
-
-
-
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
1000
-
-
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
172.57
-
-
20.2.4:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).500 mm dia piles
448
-
-
20.2.5:Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia piles
1120
-
-
20.6.3.1:Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.
Group of two or more piles upto 50 tonne capacityInitial test
2
-
-
15.58:Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
7.22
-
-
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
30.15
-
-
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
86
-
-
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
106.56
-
-
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).
190.79
-
-
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
14.4
-
-
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
64.68
-
-
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
144.93
-
-
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
260.77
-
-
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
370.83
-
-
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
11.59
-
-
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
54286.92
-
-
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
48.82
-
-
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
11.3
-
-
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
889.76
-
-
OD264025/2022-2023:12 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 ( 1 cement : 3 fine sand) .ht 19 to 22m., inside of the OH Tank including adding 2% water proofing compound by weight of cement
498.16
-
-
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
498.16
-
-
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
889.76
-
-
11.3.1:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
91.69
-
-
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
260.12
-
-
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
13.06
-
-
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
10.55
-
-
11.41.3:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm
96.58
-
-
OD264027/2022-2023:Conveying and fixing wall casting pipe in the RCC slab / wall of tank as per the direction of departmental officers.
6
-
-
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
45
-
-
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):
For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
288.65
-
-
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
12.78
-
-
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
8.4
-
-
9.9.3.2:Providing and fixing glazed shutters for door, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges bright finished of required size with necessary screws.30 mm thick
12.78
-
-
OD264028/2022-2023:Providing 110mmCI pipe and tees for vent hole with PVC Vent cowl,bend & 'T' at ends including cost and coveyance of materials.
10
-
-
OD264029/2022-2023:Providing and fixing CI Manhole cover 750mmX750mm 100 kg
4
-
-
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
500
-
-
13.71:Lettering with black Japan pint of approved brand and manufacture
3750
-
-
OD264030/2022-2023:Supplying and fixing Mechanical Water level indicators
1
-
-
OD264031/2022-2023:Supply and installation of lightening protection sytem (Lightening arresters) made of non corrosive materials ,utilize advance ance and sustainable technologie , maintain a 5 year replacement guarantee,15 years service Warranty, indipendendenly tested and certified to NFc 17102and UNE21186 standards with a protection radius of minimum 560m by capturing dangerous lightening discharges and safely channeling it to earth .
1
-
-
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
OD7504/2023-2024:Providing plumbing and Sanitary arrangement for toilet in the rest room including Water closet (European type), Urinal, Wash basin, PVS pipes and fittings, Towel rod, Health faucet, Taps, septic tank etc. complete as per the direction of departmental officers..
1
-
-
100.15.4:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 250mm diameter Ductile Iron Double Flanged pipes.
18
-
-
100.15.8:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 450mm diameter Ductile Iron Double Flanged pipes.
60
-
-
18.24:Laying in position S & S or flanged C.I. special such as tees, bends, collars, tapers and caps etc. ( excluding cost of specials).
19.06
-
-
18.30.6:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe
8
-
-
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe
20
-
-
100.31.1.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class I.
1
-
-
OD264034/2022-2023:Supplying 400mm electro-magnetic flow meter conforming to protection level of IP-68 for Flow Sensor and IP-67 for transmitter and having andaccuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing (flow sensor) to be made of SS 304/Carbon steel with anti-corrosive protection and inside liner to be made up of Hard Rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer, with provision for wireless transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions.
1
-
-
OD264035/2022-2023:Fixing 400mm electromagnetic flow meter including the cost of necessary fittings and labour charges
1
-
-
OD8033/2023-2024:Supply and laying Good Earth
759.75
-
-
OD264036/2022-2023:Supply and fixing reputed make 300mm sweep exhaust fan and connect the same with fan points complete with labour.
1
-
-
OD264037/2022-2023:Supply and fixing reputed make 1400mm sweep 3 blade with plug type electronic stage regulator and connect the same with fan point complete with labour.
2
-
-
OD264038/2022-2023:Supply and fixing reputed make 20 Watts out door LED street light fitting and connect the same with light points complete with labour.
3
-
-
OD264039/2022-2023:Supply and fixing angled button holder with LED (12 Watts) lamp and connect light point complete with labour.
5
-
-
OD264040/2022-2023:Supply and errection of reputed make 4 feet LED tube light fitting with tube on ceiling /wall and connect the same with light points with 15 sq.mm PVC insulated flexible copper wire complete with labour.
3
-
-
OD264041/2022-2023:Supply, fixing and connect 6A 3 pin plug socket and control switch in same light control box complete with labour.
3
-
-
OD264042/2022-2023: Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
21
-
-
OD264043/2022-2023:Supply, laying and connecting of earthing conductor of GI. flat/copper wires including necessary earth trenches, jointing as per IS : 3043/87 in trenches, walls, pulling through pipes etc. Copper wire No. 10 SWG
30
-
-
OD264044/2022-2023:Preparation of Electrical drawings & giving completion report,providing metering kiosk with 3nos 100A fuse units , remitting service connection charges at KSEB and getting Electrical connection from KSEB
1
-
-
Erection and commissioning 3 No's of 20HP clear water centrifugal pump sets
-
-
-
OD5652/2023-2024:Supply, erection testing and commissioning of CF pump set with the following specification 1. Pump Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete .The duty condition is as follows Discharge – 42 lps, Total head - 25 mtrs.. 2. Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V. The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors. 3. Starter - Supply, erection, testing and commissioning of suitable rating heavy duty Soft Starter for the above motor with over voltage and under voltage protections, Single phasing preventer, Over load relay with motor protection relays, and shall be provided with multifunction digital meter ,indicators and bypass contactor. 4. Panel board (suitable for operating three pump sets but to run two pump sets at a time) - Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 3 Nos of suitable capacity MCCB as outgoing (the outgoing MCCBs are to be fitted with interlocking facility so that two of them can be operated at a time) providing suitable size Aluminium/Copper bus bars to inter connect the above MCCBs and is to be fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc . Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per CEA regulations and code of practice. The panel shall be fitted on a common base frame on suitable foundation 5.Cabling work - Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set which include Cables from panel board to starter and from starter to motor. considering energy conservation 6.Earthing - Supply of all materials and providing suitable earthling by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthling to motor, starter, panel board etc. as per IE standards. 7. Capacitor - Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9. Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10 m. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80 mm MS pipes & specials shall be provided.. Two year Warranty and Supply of ELCB/RCCB to be added at panel for safety.
3
-
-
OD7952/2023-2024:Design manufacture and supply of HOT overhead traverse trolley crane 5 tonne capacity chain pulley block and geared trolley having wall to wall horizontal movement etc for smooth functioning of the crane as per IS Specification including all fittings and all incidental charges including painting the exposed surface with following specifications. Type and construction of crane Single girder HOT (Design code IS 3832) Hook IS 8610 Load chain IS 6216(Alloy steel Grade 80) Hand chain IS 2420 MS Grade 30 brake type self actuating screw friction and disc type
1
-
-
OD7993/2023-2024:Errection Lubrication testing and commissioning of HOT over head crane over the existing RS Joist provided by KWA fixed on corbell of RCC Pillers and also fixing the end of LT girder to the sides suitably and also providing with suitable end steppers including provision for box type carriage fabricated from rolled steel section and fixturs and drives like gears wheels axis rubber buffers bearing etc .The work also consist of all tools and equipments, labour supervision ,load testing all safty devices and commissioning the crane after completion of work in all respect
1
-
-
Evaluation Notes How It Works ?
Potential Partner