Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date1 Aug 2024
Closing Date28 Sep 2024
Tender Amount₹ 8,54,01,426 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100.4.7:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 3.0m (1.5m to 3.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
100.4.8:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 4.5m (3.0m to4.5m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
100.4.9:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
OD180299/2022-2023:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 7.50m ( 6.0m to 7.50 m)) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures) ( 6.00to 7.50m )

129.87

-

-

... More
OD180300/2022-2023:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9.00m (7.50 m to 9.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
OD180301/2022-2023:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.50m (9.00 m to 10.50m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
OD180302/2022-2023:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 12.00m (10.50 m to 12.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)

129.87

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

3600

-

-

... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

7200

-

-

... More
100.7.4:Bailing out water with engine and pump set above 20HP up to 30HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

7200

-

-

... More
100.6.1:Providing steel sheet shoring to the sides of the trenches to depths of above 4.00 m but not exceeding 6.00m using 6 mm M.S. sheet 0.50 M wide stiffen on edges with 50 mm x 50mm x 6 mm M.S. angles driving down vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.50 M below the bottom of the proposed excavation 0.5 M above ground level suitably braced by horizontal walling pieces at 75 x 150 mm x 8 mm angles on either side at intervals not exceeding 1.50M and horizontal screw jack type struts at 1.50M intervals and maintaining the shoring till the pipes are laid and works are completed, dismantling, cleaning and restacking for reuse including all labour, hire charges and conveyance for equipments, tools and plants and sundries etc. complete.

86.52

-

-

... More
OD253544/2022-2023:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete

150

-

-

... More
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)

1000

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

625

-

-

... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

458.94

-

-

... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining

780.73

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1028.2

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

156.72

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

30

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

149.93

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

142

-

-

... More
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

26.81

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

37.84

-

-

... More
5.22.3:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars

45950

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

24.35

-

-

... More
6.35.1:Brick work with modular calcium silicate bricks machine moulded conforming to IS:4139, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:Cement mortar 1:4 (1 cement : 4 coarse sand)

1.78

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

8.1

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

9.13

-

-

... More
21.8.1:Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width

25.8

-

-

... More
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.

173.25

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

428.44

-

-

... More
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

569.01

-

-

... More
13.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

19.67

-

-

... More
18.68.2:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Above 600 mm dia

15

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

391.76

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

284.11

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

58860

-

-

... More
OD180303/2022-2023:Gantry girder<br>Fabricating and erecting gantry girder crane of 5.00Tonne capacity designed and fabricated as per Indian Standards ,Using Indian standard steel sections like (ISHB)etc.for main girder ,Carbon steel for circular railing and grooved wheels .The assmmbly should have facility for diametrical rotation of main girder over circlar rail ,and linear chain pully block with trolly along the main girder .The whole mechanism can be easily operated from pumphouse floor .All rotatating parts shall be fitted with suitable bearings of approved quality .The non -Collinear transmission shafts incoporated if any shall be jointed with steering cross .The moving joints shall be fitted with greasing nozzle and filled bearing grease .The circular steel rail shall be well anchored with supporting concerted structure

1

-

-

... More
10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

10.24

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

13.5

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

1760.27

-

-

... More
13.37.1:White washing with lime to give an even shade:New work (three or more coats)

880.77

-

-

... More
13.39.1:Colour washing such as green, blue or buff to give an even shade:New work ( two or more coats) with a base coat of white washing with lime

870.85

-

-

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

673.44

-

-

... More
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

442.8

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

2500

-

-

... More
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.

4

-

-

... More
100.98.504:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 600mm.

4

-

-

... More
Appendix-B-Construction of Substation building, Rest room and Toilet facilities,Bridge,Side Protection work at Muriyamkanni Well site and Construction of Substation building at Poonkavam WTP site

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

67.09

-

-

... More
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)

88.69

-

-

... More
OD248992/2022-2023:DRY RUBBLE MASONRY _ Dry rubble without concrete leveling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

38.4

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

170.5

-

-

... More
OD228232/2022-2023:DOWEL BARS - Supplying and providing MS dowel bars of size 16 mm dia of 2m long (1m in rock and 1m in concrete ) including drilling holes of 20mm dia to a depth of 1m in rock and filling the gap with cement grout( 0.10kg/each) etc complete

425

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

15.86

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

5.46

-

-

... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

175.03

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

20.67

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

36.07

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

99.9

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

454.22

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

308.4

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

625.53

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

26269.58

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

73.65

-

-

... More
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

514.16

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1124.35

-

-

... More
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

954.79

-

-

... More
13.37.1:White washing with lime to give an even shade:New work (three or more coats)

2593.23

-

-

... More
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2205.52

-

-

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

120

-

-

... More
10.13.1:Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee- sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

248.4

-

-

... More
10.31:Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.

177.6

-

-

... More
14.29:Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.

325.44

-

-

... More
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes

14.4

-

-

... More
21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

15.18

-

-

... More
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

2

-

-

... More
17.7.9:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked

2

-

-

... More
17.28.1.2:Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete. Semi rigid pipe40 mm dia

20

-

-

... More
18.18.2:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

2

-

-

... More
18.58.1.2:Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole

2

-

-

... More
50.18.9.12.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12 Kgf/cm2 - External work - Exposed on wall

40

-

-

... More
50.18.9.18.1:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

100

-

-

... More
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

50

-

-

... More
100.98.48:Supply of PVC Tap

2

-

-

... More
50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.

2

-

-

... More
17.73.1:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

2

-

-

... More
18.22.1:Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter

2

-

-

... More
17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap.

2

-

-

... More
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

2

-

-

... More
17.35.1.1:Providing and fixing soil, waste and vent pipes: 100 mm diaSand cast iron S & S pipe as per IS : 1729

30

-

-

... More
11.40:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.

5.25

-

-

... More
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

270.34

-

-

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

102.24

-

-

... More
10.8.1:Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

102.24

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

16

-

-

... More
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

191.52

-

-

... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

227.52

-

-

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

40

-

-

... More
9.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.

11.8

-

-

... More
9.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters

3.36

-

-

... More
OD249128/2022-2023: PVC Septic Tank - 35 to 50 flush capacity

2

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

533.33

-

-

... More
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

122.5

-

-

... More
Appendix C - Supply,Erection,Testing and Commissioning of VT pump set at Well site and CF pump set at WTP site

-

-

-

... More
OD1855/2023-2024:Design,Supply,erection,getting approval ,testing and commissioning of reputed make vertical turbine pump with 415 volts LT motors, column pipes including providing all allied electrical connections, interconnection to the header line, inspection of pumps and accessories as per the inspectorate and KSEB standards .As per proceedings no KWA/HO/SP-333/2011/PUMPS.dated 20/12/2011 of the MD .KWA.Jalabhavan TVPM,9710/AE 15/2021/KWA dated08.02.2023 Chief Engineer(Project and Operation) KWA.(includes extended warranty one year) -150 HP to 200HP

3

-

-

... More
OD23647/2023-2024:Supplying a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules , with a power control MCCB and line power contactor , and the starting current shall be 2.5 - 3.5 times the normal full load current of motor with Ammeter , Voltmeter and Phase Indicators , space heaters , floor mounting type and having an insulation level of 1100V ( for 440 V supply ) and 7.6KV for ( 3.3 KV Supply ) and 14.2KV ( for 6.6 KV Supply ) . The standard is to be I.E.C 60947-4-2 .

3

-

-

... More
OD29847/2023-2024:Supply, Installation, Testing and Commisioning of Motor control LT panel with change over/ Interlock facility for 200 HP LT pump set . Panel board (suitable for operating three pump sets but two pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. suitable capacity MCCB as incomer and 3 nos of suitable capacity MCCB as outgoing (the three MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Suitable cables for connection with starter and motor, starter and panel board, etc. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. Super Heavy Duty Capacitors (such as A.P.P (All Polypropylene film) or M.P.P (Metalized Polypropylene film) of suitable ratings confirming to IS 7752 & BEE standards with at least one year warranty shall be used.) Capacitor Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. Valves Supply of suitable size best quality heavy duty CAST STEEL DOUBLE FLANGED valve and CAST STEEL DOUBLE FLANGED Non return/Swing check valve PN 1.60 of reputed make. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Sluice valve - 3nos, Non return valve - 3nos. Delivery pipe connections- Supply and fitting of suitable size best quality MS pipe of thickness not less than 8mm for a total length of 10m. connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main. And other necessary items

3

-

-

... More
OD2026/2023-2024:Supply & erection Testing and commissioning of LT C F pump set with the following specifications. 1. Pump 3nos (two no working at a time and one standby) Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. complete. The duty condition is as follows. Discharge per pump: 73.90 LPS Total Head: 79.00m including 3 m suction head Suction head: -ve Speed Max : 1500 rpm, Length of Pumping main 16.80 Km Dia of pumping main 350 mm DI K9 pipe 2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. (For 3300volts motors, digital motor protection relay shall be included in starter as per present IE rules). Flexible coupling shall be used for coupling of pumps and motors. 3. Starter Supply, erection, testing and commissioning of suitable rating fully automatic starter with air break contact suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. 4. Panel board (suitable for operating three pump sets but two pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. suitable capacity MCCB as incomer and 3 nos of suitable capacity MCCB as outgoing (the three MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. 6.Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. 8. Valves Supply of suitable size best quality heavy duty CAST STEEL DOUBLE FLANGED valve and CAST STEEL DOUBLE FLANGED Non return/Swing check valve PN 1.60 of reputed make. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Sluice valve - 3nos, Non return valve - 3nos. 9. Suction and delivery pipe connections Supply and fitting of suitable size best quality MS pipe of thickness not less than 8mm for a total length of 10m. Suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main. 10. Supply erection testing commissioning of suitable capacity Change over switch including panel board, suitable capacity UG cable from panel board to change over switch and to the motor in order to work two number of motors work at a time out of three in the pump house so as to limit the connected load equivalent to the capacity of two motor- 60 HP LT CF pump set

3

-

-

... More
OD2035/2023-2024:Supply & erection Testing and commissioning of LT C F pump set with the following specifications. 1. Pump 2nos( Oneno working at a time and one standby) Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. complete. The duty condition is as follows. Discharge per pump: 74.7LPS Total Head: 21.00m Suction head: -ve Speed Max : 1500 rpm, 2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. (For 3300volts motors, digital motor protection relay shall be included in starter as per present IE rules). Flexible coupling shall be used for coupling of pumps and motors. 3. Starter Supply, erection, testing and commissioning of suitable rating fully automatic starter with air break contact suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactorand bypass contactor as per IE rules and code of practice etc. complete. 4. Panel board (suitable for operating two pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. suitable capacity MCCB as incomer and 2nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. 6.Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. 8. Valves Supply of suitable size best quality heavy duty CAST STEEL DOUBLE FLANGED valve and CAST STEEL DOUBLE FLANGED Non return/Swing check valve PN 1.60 of reputed make. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Sluice valve –2 nos, Non return valve –2 nos. 9. Suction and delivery pipe connections Supply and fitting of suitable size best quality MS pipe of thickness not less than 8mm for a total length of 10m. Suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main. 10. Supply erection testing commissioning of suitable capacity Change over switch including panel board, suitable capacity UG cable from panel board to change over switch and to the motor in order to work one number of motors work at a time out of two in the pump house so as to limit the connected load equivalent to the capacity of onemotor - 30 HP LT CF pump set

2

-

-

... More
OD2042/2023-2024:Supply & erection Testing and commissioning of LT C F pump set with the following specifications. 1. Pump 2nos( Oneno working at a time and one standby) Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete including providing suitable concrete foundation including cost of cement, sand and metal etc. complete. The duty condition is as follows. Discharge per pump: 10.29 LPS Total Head: 93.00m Suction head: -ve Speed Max : 1500 rpm, 2. Motor Supply, erection, testing and commissioning of KWA prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc. complete. (For 3300volts motors, digital motor protection relay shall be included in starter as per present IE rules). Flexible coupling shall be used for coupling of pumps and motors. 3. Starter Supply, erection, testing and commissioning of suitable rating fully automatic starter with air break contact suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactorand bypass contactor as per IE rules and code of practice etc. complete. 4. Panel board (suitable for operating two pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No. suitable capacity MCCB as incomer and 2nos of suitable capacity MCCB as outgoing (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar interconnect the above MCCBs and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch, 1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. 6.Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. 7. Capacitor Supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834. 8. Valves Supply of suitable size best quality heavy duty CAST STEEL DOUBLE FLANGED valve and CAST STEEL DOUBLE FLANGED Non return/Swing check valve PN 1.60 of reputed make. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. Sluice valve –2 nos, Non return valve –2 nos. 9. Suction and delivery pipe connections Supply and fitting of suitable size best quality MS pipe of thickness not less than 8mm for a total length of 10m. Suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with valves and suitable specials to connect with the pumping main. 10. Supply erection testing commissioning of suitable capacity Change over switch including panel board, suitable capacity UG cable from panel board to change over switch and to the motor in order to work one number of motors work at a time out of two in the pump house so as to limit the connected load equivalent to the capacity of onemotor

2

-

-

... More
OD260565/2022-2023:Supply, Erection, testing and commissioning of 3 HP pump set for priming with all necessary electrical and pipe line work- Pump water from the clear water sump at WTP to fill the pumping main to create the suction force at the centrifugal pumps

1

-

-

... More
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

50

-

-

... More
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

10

-

-

... More
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

8

-

-

... More
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

8

-

-

... More
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

8

-

-

... More
Appendix D - Supply,Erection,Testing and Commissioning of 630 KVA 11KV/433 volts Indoor Transformer and connected works at Muriyamkanni Well site

-

-

-

... More
OD259005/2022-2023:11 KV Equipments-Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards<br>

1

-

-

... More
OD259727/2022-2023:11KV Metering Unit <br>Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: <br>Current Transformer<br>CT Ratio 20/5 A( actual ratio may be decided after calculating connected load& maximum demand)<br>Burden 15VA<br>Accuracy Class 0.2S<br>Potential Transformer<br>PT ratio 11KV/110V<br>Burden -100VA.<br>Accuracy Class 0.2<br>The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.<br>

1

-

-

... More
OD259728/2022-2023:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.

1

-

-

... More
OD259729/2022-2023:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat.

60

-

-

... More
OD259730/2022-2023:TOD Meter<br>Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. <br>

1

-

-

... More
OD259731/2022-2023:11KV Switchgear(Indoor)<br>Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments( A, V, KW, PF), protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.

1

-

-

... More
OD259732/2022-2023:Supply, erection, testing and commissioning of 433V, 3phase,4 pole, 1000A, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type panel board comprising of 5 panel system (1 nos 800A MDO ACB as incomer, and 3 numbers 250 A microprocessor based MCCB (suitable for induction motor application) & 100A MCCB as outgoings) The incomer switchgears, & outgoing switchgears should be suitable for installation in 3 phase , 3wire, 50Hz. AC, 433V, effectively earthed supply system, trip free closing mechanisum and all metering equipments, protective relays, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of panel.

1

-

-

... More
OD259733/2022-2023:11KV/433V, 630KVA Transformers (Indoor type suitable for parallel operation). Supply, erection, testing and commissioning of 630 KVA, 11KV/433V. 3phase, 50Hz. copper wound indoor type transformer with OLTC with digital AVR, 17 tap positions +5 to -15 % variation, with HV and LV side cable end box arrangements, with RTCC panel including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.

1

-

-

... More
OD259735/2022-2023:Supply, installation,testing and commissioning of Neutral CT for transformer protection, ratio - 125/5A(or suitable ratio), class 5P10 neutral CT with suitable size weather proof enclosure with iron frame work including all accessories.

1

-

-

... More
OD259737/2022-2023::Power Distribution board (PDB)<br>"Supply,erection, testing and commissioning of 8 way MCB distribution board comprising to the following. 63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and 20A TP MCB-2Nos. & 20A SP MCB- 6 Nos each. as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."<br>

1

-

-

... More
OD259738/2022-2023::Lighting Distribution board (LDB)<br>"Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system."<br>

1

-

-

... More
OD259739/2022-2023:Cabling- Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3.5 core 400sqmm 1100 volts XLPE Aluminium cable (4 runs)

50

-

-

... More
OD259740/2022-2023:3 core 240 sq mm11kv, XLPE AL Cable

150

-

-

... More
OD259741/2022-2023: 3 core 185 Sq.mm,1100V LT XLPE AL Cable

120

-

-

... More
OD259742/2022-2023:3.5 core 50Sq.mm. AYFY Cable

40

-

-

... More
OD259743/2022-2023:4 core 16 Sq.mm.PVC AL. Cable.

100

-

-

... More
OD259744/2022-2023:4 core 10 Sq.mm.PVC AL. Cable.

60

-

-

... More
OD259746/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 kv grade as required 3 core 240 sq mmxLPE 11 KV Cable(Outdoor)

1

-

-

... More
OD259748/2022-2023:3.5 core 400 Sq.mm. Cable end termination

7

-

-

... More
OD259747/2022-2023:3 core 185 Sq.mm.1100v,LT XLPE AL Cable end termination (Indoor)

7

-

-

... More
OD259749/2022-2023:3.5 core 50Sq.mm. AYFY Cable

5

-

-

... More
OD259750/2022-2023:4 core 16 Sq.mm.PVC AL. Cable.

8

-

-

... More
OD259751/2022-2023:4 core 10 Sq.mm.PVC AL. Cable.

6

-

-

... More
OD259752/2022-2023:Plate Earthing<br>Plate earthing as per IS by using CI/GI plate of size 1200*1200*12 mm etc complete

11

-

-

... More
OD259753/2022-2023:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.<br>

150

-

-

... More
OD259754/2022-2023:25x3mm copper strips.

150

-

-

... More
OD259755/2022-2023:25x6mm GI strips

200

-

-

... More
OD259756/2022-2023:32x6mm GI strips.

150

-

-

... More
OD259757/2022-2023:MS Items.<br>Supply and fixing of 6mm thick chequered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.

1.5

-

-

... More
OD259758/2022-2023:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.

1

-

-

... More
OD259759/2022-2023:Battery& Battery Charger.<br>Supplying, fixing, testing and commissioning of Lead acid cell battery 24V, 200AH capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific

1

-

-

... More
OD259760/2022-2023:Supplying, fixing, testing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc. complete as per standards.

1

-

-

... More
OD259761/2022-2023:Safety Items<br>Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.

1

-

-

... More
OD259762/2022-2023:Internal and External Lighting

1

-

-

... More
OD259763/2022-2023:Provision for making drawing and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA)

1

-

-

... More
Appendix E - Supply,Erection,Testing and Commissioning of 315 KVA 11KV/433V Indoor type Transformer and connected works at WTP Poonkavanam Dam site

-

-

-

... More
OD257473/2022-2023:Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete including earthing, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards

1

-

-

... More
OD257483/2022-2023:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical channel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat including supply and spreading of river sand to a depth of 5 cm from ground level and spreading 40mm granite metal over this to a height of 10cm above ground level for the entire yard area with side protection using cement brick.

60

-

-

... More
OD257487/2022-2023::Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.

1

-

-

... More
OD257498/2022-2023:TOD Meter<br>Supply, erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk. The TOD meter shall satisfy KSEB specifications in force .The rate shall include the cost of testing the equipment at KSEB and all other incidental expenses.

1

-

-

... More
OD257496/2022-2023:Supply, erection, testing and commissioning of out door type metering unit consisting of the following accessories: <br>Current Transformer - CT Ratio 200/5 A( actual ratio may be decided after calculating connected load& maximum demand), Burden 15VA. Accuracy Class 0.2S<br>Potential Transformer- PT ratio 11KV/110V, Burden -100VA., Accuracy Class 0.2<br>The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.<br>

1

-

-

... More
OD257492/2022-2023:11KV Switchgear(Indoor)<br>Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments( A, V, KW, PF), protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.

1

-

-

... More
OD257506/2022-2023:433 V LT Panel<br>Supply, erection, testing and commissioning of 433V, 3phase,4 pole, 1000A, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type panel board comprising of 5 panel system (1 nos 800A MDO ACB as incomer, and 3 numbers 250 A microprocessor based MCCB (suitable for induction motor application) & 100A MCCB as outgoings) The incomer switchgears, & outgoing switchgears should be suitable for installation in 3 phase , 3wire, 50Hz. AC, 433V, effectively earthed supply system, trip free closing mechanisum and all metering equipments, protective relays, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of panel.

1

-

-

... More
OD257510/2022-2023:Power Distribution board (PDB) <br>Supply,erection, testing and commissioning of 8 way TPN MCB distribution board comprising to the following. 63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and 20A TP MCB-2Nos. & 20A SP MCB- 6 Nos each. as outgoings, <br> With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system.<br>

1

-

-

... More
OD257514/2022-2023:Supply, installation,testing and commissioning of Neutral CT for transformer protection, ratio - 125/5A(or suitable ratio), class 5P10 neutral CT with suitable size weather proof enclosure with iron frame work including all accessories.

1

-

-

... More
OD257518/2022-2023:11KV/433V, 315KVA Transformer (Indoor type )[RWP]<br>Supply,erection, testing and commissioning of 315 KVA, 11KV/433 V. 3phase, 50Hz. ONAN cooled , indoor type copper wound power transformer, suitabe for parrallel operation, with HV and LV side cable entry box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with RTCC panel with AVR control relay and local & remote indication of tap position, and including first filling of oil , earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of neutral grounding CT, control cables both internal and external shall be included in the cost of Transformer.

1

-

-

... More
OD257545/2022-2023:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable 11kv grade clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.

444630

-

-

... More
OD257549/2022-2023:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable 11kv grade for giving power connections to Transformers, Panel boards etc. complete as per standards.

201091

-

-

... More
OD257606/2022-2023::Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, LT panel boards, equipments and inter connection of earth pits etc.

343600

-

-

... More
OD257598/2022-2023:Plate earthing as per IS by using CI/GI plate of size 1200*1200*12 mm etc complete

10

-

-

... More
OD257619/2022-2023:Supply and fixing of 6mm thick chequered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.

5

-

-

... More
OD257627/2022-2023:Safety Items ( Raw water, WTP)<br>Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.

1

-

-

... More
OD257628/2022-2023:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.

0.5

-

-

... More
OD257633/2022-2023::Battery& Battery Charger.( WTP)<br>Supplying, fixing, testing and commissioning of Lead acid cell battery suitable voltage and capacity according to control voltage of panels and other equipment’s capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific gravity 1.190 and accessories such as voltmeter, Thermometer, Hydrometer, spaners etc with teak wood stand with 3 coats of antiacid paint to accomodate battery.

1

-

-

... More
OD257637/2022-2023:Supplying, fixing, testing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc. complete as per standards.

1

-

-

... More
OD257646/2022-2023:Internal and External Lighting provisions including MCB distribution boards, modular switch boards, wiring, fans, exhaust fans, external and internal lighting fixtures etc complete with earthing and RCCB ( WTP)

1

-

-

... More
OD257667/2022-2023::Provision for soil resistivity mesurements, design of earthing and protection, making electrical scheme and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA)(WTP & RWPH)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.