Kerala Water Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 37,986Document Cost
₹ 2,760Tender Fee
Refer Documents
Summary
R1-jjm Erumely -overhauling Of 500kva Transformer And Allied Electrical Works Including Obtaining Ht Power Connection At 10mld Wtp, Erumely And The Pending Electrification Works At Kanamala Boosting Station
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KWA_724954_1Bid Award Id
ViewTender No
WRD/KWA-CE(SR)/TR/24202/2024Tender Authority
Kerala Water Authority ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General conditions of E Tendering Process
BOQ Items
... More
OD149764/2024-2025:Overhauling and reconditioning three stage Wilo Mather and Platt make 120HP CF pump of 2975 RPM. Disengage pump & motor couplings, remove coupling key, NDE/DE Bearings from shaft by using bearing puller, remove oil seals, shoulder seals from shaft, remove stuffing box cover, gland etc, taking casing wear rings, unscrew DE/NDE shaft sleeves, remove impeller from shaft, remove impeller key, check mechanical seals, O rings etc, conveying shaft to lathe for machining if required, tuning and dynamic balancing of impeller, conveying back to TWPS, cleaning bearing housing and glands, refixing bearings, mechanical seals, shoulder seals, Oil seals, O rings, studs, nuts & bolts, gaskets, Gland packing and cleaning from dirts, oil and grease, reassembling the pump, coupling with motor, trial run etc complete. The cost is inclusive of all labour charges and cost of all seals, O rings, studs, nuts & bolts, gaskets, gland packings, lock nut etc to be replaced.
2
-
-
... More
OD149806/2024-2025:Servicing and overhauling of 800A/1000A 50kA MDO type ACB including supply of ACB maintenance kit, Visual inspection for any broken parts and replace as needed. Clean and lubricate all mechanical linkages. Inspect all breakers, remove all covers and arc extinguishing shields, inspect for damage, wear and deterioration, clean and lubricate as required. The rate is inclusive of all labour and cost of damaged parts to be replaced.
1
-
-
... More
OD149822/2024-2025:Supply and erection of 3.3/11kV Vacuum circuit breaker of draw out type suitable for installation in the existing switchgear cubicles (indoor). The breaker shall comply with IEC 62271-100 / IS13118 (1991) for circuit breaker and IEC 62271-200 for the switch gear and latest amendment thereof. Construction of breaker shall be such that the points, which require frequent maintenance, shall be easily accessible. The circuit breakers shall be spring operated, motor/manually charging of the spring feature, manually released. VCB shall have spring closing mechanism for 3pole simultaneous operation. The speed of closing operation shall be independent of the speed of hand operating level. The indication device shall show the OPEN and CLOSE position of breaker visible from the front of cubical. The circuit breakers shall be type tested as per IEC 62271.
1
-
-
... More
OD149825/2024-2025:Servicing of 500kVA Transformers, conveying to workshop including loading and unloading at bothends, checking all copper contacts including all labour and cost of consumables such as grease, belt, packings etc, conveying back to WTP including cost of copper contacts, castle key and any spare to be replaced.
1
-
-
... More
OD149826/2024-2025:Testing of Earth pits for earth resistance and reducing earth resistance to desired levels if found necessary by exposing earthing electrode, replacing nuts & bolts with new SS bolts & nuts, earth plate and pipes if required and adding required quantity of earthing compound etc complete as per IEEE standards.
2
-
-
... More
OD149827/2024-2025:Transformer Spray painting for 500 kVA transformer including scrubbing and cleaning old painted surface, applying metal/epoxy putty at corroded portions and spray painting two coats of epoxy paint.
1
-
-
... More
OD149831/2024-2025:Supply and providing HT end termination / straight jointing for 3 core XLPE Copper or Aluminium Conductors of 35 to 400sqmm size, 3M/eq Make including all labour charges for jointing, cost of end termination / straight jointing kit etc complete
2
-
-
... More
OD149842/2024-2025:Supply installation and commissioning of Outdoor type CTPT unit at site: 1set Instrument transformer - Potential Transformer Assembly-11 KV Oil Type CT PT Unit Ratio - 11KV/110 V, Burden : 25 VA, CL.: 0.2S, Current Transformer- 15/5 A, 10 VA, CL : 0.2S or suitable type as directed by KSEB based on the Contract demand.
1
-
-
... More
OD149843/2024-2025:Supplying of KSEB approved make TOD meter, 3phase, 4 wires, DLMS compatible, accuracy class 0.2 S, confirming to the new guidelines of KSEB and KSEI
1
-
-
... More
OD149832/2024-2025:Testing of CT PT unit & TOD meter including conveyance to KSEB TMR unit Pallom and back to WTP after testing, Loading and unloading charges at both ends , dismantling and removing existing CTPT unit, lifting and installation of new CTPT unit at 2Pole structure etc complete (testing fee will be paid by the department).
1
-
-
... More
OD149886/2024-2025:Supply and installation of 10kVAR Metalised Poly Propeline Power Capacitor Heavy Duty of L&T/eq make Cylinderical gas filled type, delta connected 3 phase 440V with discharge resistors.
4
-
-
... More
OD149887/2024-2025:Supply and installation of 5kVAR Metalised Poly Propeline Power Capacitor Heavy Duty of L&T/eq make Cylinderical gas filled type, delta connected 3 phase 440V with discharge resistors.
2
-
-
... More
OD133069/2024-2025:Charges for 120 HP soft starter repairing and servicing including all labour charges and cost of spares required
2
-
-
... More
OD133074/2024-2025:Supply and testing EFR relay
1
-
-
... More
OD133075/2024-2025:Supply and testing neutral CT
1
-
-
... More
OD133078/2024-2025:Statutory Approval - Obtaining statutory approval from Eletrical Inspectorate including preparation of drawings, obtaining approval for the drawings arranging inspection of the installations and obtaining safety certificate etc.after completion of the work and avail supply from KSEB including paper related works and inspection from KSEB and Electrical Inspectorate. The necessary statutory fees if any payable to the Electrical Inspectorate/ KSEB will be paid by KWA (Note: Scheme approval from the Electrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials (Electrical side ) will be released only on production of scheme Approval.)
1
-
-
... More
Appendix A1 -WSS to Erumely pending electrification works at CWPH Kanamala
-
-
-
... More
OD133080/2024-2025:Supply installation and commissioning of KSEB METERING PANEL (Outdoor type) KSEB meter board complete with all interconnections, provision for fixing 3 phase CT operated energy meter 1no. 100A fuse unit with 80A HRC -3 Nos and 1No neutral link. 80A 4P MCCB-1No as per KSEB standard.
1
-
-
... More
OD133082/2024-2025:Supply installation and commissioning of Main Switch Board Incomer: 100A TPN ISO -1No, RYB Indication -1Set, Volt meter with Voltage Selector Switch -1No, Outgoing: 63A TPN MCCB -1No & 32A TPN MCCB -1No including all labour charges and cost of all as follows. 1.MR1492 Supply of current limiting type TP/TPN MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC 100A125A/160A 30/50kA 2.MR1491 Supply of current limiting type TP/TPN MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL& SC 16A/32A/63A 30/50kA (63 A 1N0, 32 A 1 No)
1
-
-
... More
OD133084/2024-2025:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (8way SPN DB (Double door) with the following 40A DP MCB ISO -1No 40A 30mA RCCB -1No 10A SP MCB -2No 16A SP MCB-1 no)
1
-
-
... More
OD133085/2024-2025:Supply and laying of following AYFY UG cables of size 3.5C x 50sqmm, through trenches/ wall/ existing trays /pipes etc. including supply & fixing of necessary clamping materials if required
6
-
-
... More
OD133086/2024-2025:Supply and laying Aerial Bunched Cable ( LT 50sqmm (3x50+1x35+1x16)
25
-
-
... More
OD133087/2024-2025:Supply of all materials and providing cable end termination, including gland earthing etc. as complete with suitable gland and crimping sockets for the cables of 50/35/16sqmm size.
2
-
-
... More
OD133088/2024-2025:Providing pipe earth electrode of 38 mm ‘B’ class GI pipe of 2.5 m long including providing charcoal, necessary fasteners etc. as per the IS 3043. The cost include excavation back filling consolidating soil providing masonry chamber with CI cover etc complete as per IEEE standards.
2
-
-
... More
OD133089/2024-2025:Supply, fixing and giving termination to the following Cu/ GI strips and wires for effective earthing of the system (10 SWG Cu)
40
-
-
... More
OD133090/2024-2025:Copper Earth Bench made of 25x3mm copper and duly tinned to take multiple Earth connections
2
-
-
... More
OD133091/2024-2025:One light point/ ex.fan point/ call bell controlled by one 6A switch and 3 plate ceiling rose if necessary
13
-
-
... More
OD133092/2024-2025:Single control ceiling fan point with 6A 3 plate ceiling rose and with socket size stepped electronic regulator
1
-
-
... More
OD133093/2024-2025:6A 5 pin plug socket controlled by 6A switch in the same switch board as that of light points
1
-
-
... More
OD133094/2024-2025:Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories in recess including cutting the wall and making good the damages etc as required for circuit mains wiring. (20 mm dia medium gauge)
5
-
-
... More
OD133095/2024-2025:Supply and drawing following size of FRLS PVC insulated stranded single core copper conductor cables in the existing surface / recess conduit as required including giving necessary connections of the following sizes for circuit mains 1.00 sqmm x 3 run
30
-
-
... More
OD133096/2024-2025:Supply and drawing following size of FRLS PVC insulated stranded single core copper conductor cables in the existing surface / recess conduit as required including giving necessary connections of the following sizes for circuit mains 1.50 sqmm x 3 run
16
-
-
... More
OD133097/2024-2025:Supply and drawing following size of FRLS PVC insulated stranded single core copper conductor cables in the existing surface / recess conduit as required including giving necessary connections of the following sizes for circuit mains 2.50 sqmm x 2run and 1.50 sqmm x 1run
4
-
-
... More
OD133098/2024-2025:16A power plug-2M + 16A switch with indicator-1M
1
-
-
... More
OD133099/2024-2025:Supply conveyance, installation, testing and commissioning the following types of light/ fan fittings with all accessories and lamps directly on wall/ ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 20 watts LED tube (Philips/ Dewton
8
-
-
... More
OD133100/2024-2025:Supply conveyance, installation, testing and commissioning the following types of light/ fan fittings with all accessories and lamps directly on wall/ ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required Street light fittings from building 36 watts
2
-
-
... More
OD133101/2024-2025:Supply conveyance, installation, testing and commissioning the following types of light/ fan fittings with all accessories and lamps directly on wall/ ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required Angle battern holder with 7 watts LED bulb
2
-
-
... More
OD133102/2024-2025:Supply conveyance, installation, testing and commissioning the following types of light/ fan fittings with all accessories and lamps directly on wall/ ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200mm ceiling fan (ordinary type-Cropton-Ariya Breez
1
-
-
... More
OD133103/2024-2025:Supply conveyance, installation, testing and commissioning the following types of light/ fan fittings with all accessories and lamps directly on wall/ ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required Exhaust fan 6" round type (Crompton)
1
-
-
... More
OD133104/2024-2025:Preparation of necessary documents, submitting to KSEBL and arranging inspection for getting Power connection from KSEBL (excluding statutory fees)
1
-
-
... More
Supply and Fixing Zero Velocity Valve and allied Works
-
-
-
... More
OD133062/2024-2025:Design, Supply and fixing of 250mm Zero velocity valve(Flanged type) with all required accessories and specials for fixing at suitable location in pumping main including design and construction of suitable RCC valve chamber
1
-
-
... More
OD133063/2024-2025:Design, supply, conveying and fixing of 100mm Zero velocity valve(Flanged type) with all required accessories and specials for fixing at suitable location in pumping main including design and construction of suitable rcc valve chamber
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements