Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Civil Works Others
Water Storage And Supply
Eprocure
Opening Date8 Oct 2024
Closing Soon21 Oct 2024
Tender Amount₹ 39,43,83,511 
Notes
Download

Costs

Summary

Construction Of Intake Well, Booster Station, Ohsr, Water Treatment Plant, Supplying And Laying Of Pumping Main, Supply And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100.4.3:Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift upto 3.00m(1 st depth 1.50m to 3.00m) but excluding bailing out water. (Ref. Item No. 1098 (b) of T C)

264.94

-

-

... More
100.4.4:Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift upto 4.50m( 2 nd depth 3.00m to 4.50m) but excluding bailing out water. (Ref. Item No. 1098 (c) of T C)

264.94

-

-

... More
100.4.5:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 6.0m (4.5m to 6.0m) but excluding bailing out water.

264.94

-

-

... More
OD193199/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 7.5m (6.0m to 7.5m) but excluding bailing out water.

264.94

-

-

... More
OD193198/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 9.0m (7.5m to 9.0m) but excluding bailing out water.

264.94

-

-

... More
OD193197/2023-2024:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 10.5m (9.0m to 10.5m) but excluding bailing out water.

134.81

-

-

... More
OD164458/2023-2024: Providing 20mm tor steel dowel rods at bottom of the well at 30cm in two rows for fixing the curb with bottom hard rock layer including cost of materils, labour charges etc. complete

250

-

-

... More
OD164500/2023-2024:Construction of temporary bund using earth filled cement bags including cutting of the Earth, filling, conveying and placing in position, Filling with contractor's own earth (excluding rock) in the core portion of the earthen bund by consolidating each deposited layer by ramming and watering, Supplying, conveying and coveringusing best quality polythene sheet on bund to protect bund from seasonal changes, Conveying and providingbamboo poles at the rates of 3m per 4m3 (1m each in longitudinal, horizontal and vertical directions) for reinforcingthe temporary bund, dismantling the sand / earth filled cement bag from the foundation site of bund, appron on both sides, counter wall and removing the sand/earth from the bag and dispossing the damaged cement bags properly asper the direction of the department officers including all cost, labour charges and hire for tools and plant etc complete. Bund size 1.50x3.0x2.50 m<br>

60

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

7500

-

-

... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

8000

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

29.73

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

512.13

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

225.85

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

772.61

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

2

-

-

... More
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining

1591.82

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

667.18

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

679.86

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

149.12

-

-

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

16.88

-

-

... More
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

330.11

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

65568.99

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

77.77

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

854.16

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

1508.11

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

824

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

720

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

259.42

-

-

... More
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

119.7

-

-

... More
21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

0.95

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

44.28

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

10.05

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

854.16

-

-

... More
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

205.2

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

33.75

-

-

... More
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

805.22

-

-

... More
OD164457/2023-2024:Supply, fabrication and erection of support for chequared plate at site including cutting hoisting and fixing in position and painting the exposed surface with a coats of steel primer and 2 coats of aluminum paint including cost of labour charges and conveyance of all materials, etc. complete and as directed by the departmental officers

4903.86

-

-

... More
OD164456/2023-2024:Design manufacture supply of 7T capacity electrically operated over head crane arrangements suitably positioned on appropriate ISMB steel sections used as main girders, carbon steel for circulating railing and grooved wheels. The entire assembly shall be capable for three dimensional lifting operations covering the entire pump house area. The whole mechanism must be easily operated from the pump house floor and all the rotating parts shall be fitted with suitable bearings of international quality. The collinear transmission shall incorporated if any shall be jointed with steering cross and rivets. The gear box and transmission arrangements of the crane must be designed for smooth and easier operations. The motors and other electrical fitting connected with the crane shall be comply to relevant Indian Standards. All necessary safety arrangements shall be incorporated in the crane arrangements such as stoppers, overhead protection, earthling etc. The entire installations shall be painted using aluminum paint after two priming coat. An operation manual of the same also be supplied. The trolley frame shall be steel box sections and axial bearing shall be superior roller type. Wheel assembly should be fitted in L type housing and trolley wheel shall be medium carbon alloy steel solid forged with BHN 341. All gear boxes shall be completely enclosed having splash lubricated type scaled with neoprene O ring

1

-

-

... More
OD164455/2023-2024: Erection and commissioning of the above specified 7T capacity electrically operated over head crane arrangements suitably positioned on the appropriate ISMB steel sections including providing and fixing suitable side 45 x 45 MS base plate 18mm thick over the existing RCC pillars brackets by drilling, fixing belt of suitable size and grouting with CM and welding LT girder ISMB 550 with cover plate 20mm thick and circular girder ISMB 250 with required MS base plate if any and also fixing the ends of the LT girder to the size suitably and also providing LT rail with suitable end stoppage. This also includes provision for box type fabricated from rolled steel section and carriages of suitable construction with all good quality accessories like gears, wheels axis rubber buffers, bearing etc, the work also consists of all tools and equipment's , labour, supervision, load testing all safety devices required for the satisfactorily operation etc.. The rate inclusive of MS base plate, stoppers and carriage, all required accessories, painting with aluminum paints including trial run etc. complete

1

-

-

... More
OD164454/2023-2024:Supplying and fixing Lightning Arrestor including lightning conductor of GI 7/10” SWG (10mm) diameter<br>standard wire with lightning rod of 25mm diameter, 0.9 meters long with earth electrode 25mm diameter,<br>2.75 meters long GI pipe from ground level connecting 50mm diameter, 1.40 meters long perforated GI<br>pipe including fixing of clamps as per IS:2309. fixing all accessories etc complete

1

-

-

... More
OD164453/2023-2024:Intake arrangement at well at three levels at river side SS frame 65x65x8mm for 2x2m opening in well, SS grill over opening for screening, SS shutter with 16mm thick SS plate with frame and rubber sealing for the opening, 25mm SS rod for operating the shutter with lever and key arrangement at the well plat form for operating at different water levels

3

-

-

... More
OD164452/2023-2024: Towards the charges for supply , errection and commissioning of 5HP reputed make (Kirloskar)monoblock Vaccum pump set with all accesseries including GI/MS pipe connection to siphon pipe , control valves etc including erection charges as per site condition and Engineer in charge

5

-

-

... More
22.4.3:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Kickers (320 mm wide, 5 mm thick)

78.5

-

-

... More
OD188433/2023-2024: Supplying and fitting chequered plate including all cost of materials ,conveyance and labour charges etc.complete.

15543

-

-

... More
18.68.2:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Above 600 mm dia

2.18

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

500

-

-

... More
Transformer Building and Retaining wall at Intake well

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

700

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

313.37

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

417.83

-

-

... More
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)

313.37

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

299.76

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

46.03

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

283.97

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

394.69

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

549.22

-

-

... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

3.85

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

200.74

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

590.42

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

354.62

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

19.61

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

39655.91

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

57432.79

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1066.55

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

242.93

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

280

-

-

... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

4.18

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

68.36

-

-

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

11.8

-

-

... More
13.65.1:Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work

372.1

-

-

... More
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

73.13

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

23.34

-

-

... More
21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

27.71

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

1180.8

-

-

... More
9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

4.9

-

-

... More
9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

1.8

-

-

... More
17.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover

6.2

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.05

-

-

... More
9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters

1.61

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

29.52

-

-

... More
13.85.1:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood ) having VOC content less than 50 grams/ litre

29.52

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

10.65

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

176.75

-

-

... More
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

1

-

-

... More
17.69.2:Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms

1

-

-

... More
17.70.1:Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

1

-

-

... More
18.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore

2

-

-

... More
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

2

-

-

... More
18.55.1:Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms

2

-

-

... More
18.58.1.2:Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole

1

-

-

... More
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

6

-

-

... More
50.18.8.1.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 12 Kgf/ cm2

12

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

5000

-

-

... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

10000

-

-

... More
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

91.24

-

-

... More
13.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

1303.48

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

0.61

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

1

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

1500

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5073.07

-

-

... More
100.52.S.2:Sub Data for Filling with contractor's own earth (excluding rock) in the core portion of the earthen bund by consolidating each deposited layer by ramming and watering, as per direction of the departmental officers.

4550

-

-

... More
Construction of ACCESS BRIDGE to Intake well

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

350

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

65.72

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

98.58

-

-

... More
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)

98.58

-

-

... More
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)

65.72

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

99.35

-

-

... More
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

5000

-

-

... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

7500

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

22.93

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

128.96

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

317.69

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

74.46

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

907.34

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

404.52

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

38288.01

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

686.67

-

-

... More
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

2495.23

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

686.67

-

-

... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

4.6

-

-

... More
OD198734/2023-2024:Providing 20mm tor steel dowel rods at bottom of the pier footing 1m in length for fixing the foundation with bottom hard rock layer including cost of materils, labour charges etc. complete

320

-

-

... More
AERATOR

-

-

-

... More
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

196

-

-

... More
2.33.1:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

8

-

-

... More
2.33.2:Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

4

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

190.02

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

12.78

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

8.55

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

3.76

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

27.27

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

31.03

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

28.6

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

274.97

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

451.44

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

3272.4

-

-

... More
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

16.64

-

-

... More
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

170.4

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

116.16

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

59.92

-

-

... More
13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

27.41

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

145.97

-

-

... More
FLOCULATOR and CLARIFIER

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1039.33

-

-

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

30.64

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

785.83

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

30.64

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

8.4

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

24.98

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

49.11

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1120.39

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

42.32

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

14.08

-

-

... More
4.20.2.1:Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Note : 1) Excess /less cement used than specified in this item is payble / recoverable separately. All works above plinth and upto floor V level :M- 15 grade plain cement concrete (cement content considered @ 240 kg /cum)

44.83

-

-

... More
5.9.20:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick

27.6

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

335.84

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

335.84

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

41979.38

-

-

... More
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

1759.32

-

-

... More
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

266.72

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

165.6

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

242.88

-

-

... More
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

264.2

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

264.2

-

-

... More
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

1011.88

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

206.7

-

-

... More
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

44

-

-

... More
OD186672/2023-2024:Providing and fixing 404 stainless steel plates for settlers and support structures for water treatment, Inclined Chanel support ,top cover,side support,weir for water out flow,SS 404 nuts and bolts, welding etc settlers and side supporting cover are fabricated using high graded stainless steel SS 404 suitable for use in the water and waste treatment plants to improve the quantity and quality of water production. with all required accessories-(effective size of plate length-1.5m,width-1.2m,thichness-0.7mm.) as per the direction of departmental officers.

920

-

-

... More
Filter house and Clear Water Sump

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

1440

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

3660.39

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

1733.44

-

-

... More
100.2.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock Requiring Blasting.

1152.94

-

-

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

1441.18

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

1441.18

-

-

... More
4.20.2.1:Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. Note : 1) Excess /less cement used than specified in this item is payble / recoverable separately. All works above plinth and upto floor V level :M- 15 grade plain cement concrete (cement content considered @ 240 kg /cum)

160.62

-

-

... More
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

811.29

-

-

... More
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

924.12

-

-

... More
5.15:Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in lintels, beams and bressumers including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but excluding the cost of reinforcement with, 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

22.74

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

1522.81

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

81128.9

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

101653.31

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

116.01

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1036.89

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5485.48

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

1110.97

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3207.53

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

154.12

-

-

... More
6.3.1:Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks

17.02

-

-

... More
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

524.82

-

-

... More
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

78.84

-

-

... More
21.13:Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

3

-

-

... More
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

899.1

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

29.97

-

-

... More
9.141:Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge.

13.2

-

-

... More
9.142.1:35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC ( ±0.2 mm) thick, having styles & rails (except lock rail ) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinges side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm s 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge.Non decorative finish (matt finish)

4.8

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

28.05

-

-

... More
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

3025.89

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

13601.48

-

-

... More
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

9496.57

-

-

... More
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

624.84

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

1604.08

-

-

... More
11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.

452.9

-

-

... More
OD187938/2023-2024:Providing and fixing Water level indicator for service reservoirs

2

-

-

... More
OD187940/2023-2024:Supplying and fixing lightening arrester to OHSR by providing 1No. copper spike at the top of tank, clamping 20x3mm aluminium strip along horizontal run and 25x3mm aluminium strip along vertical run using GI fabricated clamps the spacing of clamp not exceeding 1m,rivetting,sweasing and soldering each end of aluminium tape using 2Nos.6mm dia GI bolts nuts, revets including drilling holes etc., and providing 4Nos.of earting on 40mm dia GI pipe,each 3m long including construction of masonry trough with cover slab, watering filling, with charcoal/coke, slat etc., as per IE rules and IS specification etc., complete.

2

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

6

-

-

... More
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

7643.25

-

-

... More
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

7643.25

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

500

-

-

... More
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.

2490.53

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

182.25

-

-

... More
50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall

50

-

-

... More
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall

30

-

-

... More
50.18.7.5.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6Kgf/cm2 - Internal work - Exposed on wall

20

-

-

... More
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

25

-

-

... More
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend

7

-

-

... More
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

2

-

-

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

3

-

-

... More
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

3

-

-

... More
17.32.2:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm

5

-

-

... More
OD188000/2023-2024:Supplying Anthracite ( shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications, as per approved drawings, as per order no.KWA/WASCON/AEE-II/697/2018 dated 23/3/2019 and as per Technical Circular no. KWA/JB/TMU/4659/2021 dated 17/3/2021.

128.06

-

-

... More
100.55.1:Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.

64.03

-

-

... More
100.55.2:Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.

21.34

-

-

... More
100.55.3:Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification.

21.34

-

-

... More
100.55.4:Supplying and stacking for measurement of filter sand having effective size 0.45 to 0.70 mm and uniformity coefficient 1.30 to 1.7, of specific gravity in the range of 2.55 - 2.65 and hard and clean, free from clay, dust and other impurities including cost of materials, labour charges and conveyance of materials up to 5 km and as per the directions of the department officers etc. complete and as per CPHEEO specification.

64.03

-

-

... More
Recycling unit

-

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

336.96

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

456.07

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

294.84

-

-

... More
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

196.56

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

30.79

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

154.11

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

43.69

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

197.8

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

28.87

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

488.97

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

214.38

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

34.04

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

11.14

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

13.91

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

18493.44

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

5242.56

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

16.2

-

-

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

3.27

-

-

... More
22.4.3:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Kickers (320 mm wide, 5 mm thick)

62.1

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

531.99

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

407.56

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

252.91

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

6.75

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

378.49

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

153.5

-

-

... More
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.

500

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

5.25

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

272

-

-

... More
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

16.88

-

-

... More
21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

9.59

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

5.39

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

270

-

-

... More
Chemical Room

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

304

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1063.13

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

1063.13

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

37.93

-

-

... More
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

50.57

-

-

... More
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

37.93

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

1487.37

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

13.28

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

27.76

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

109.83

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

99.1

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

347.65

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

171.24

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

269.4

-

-

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

20.2

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

187.6

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

118.81

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

18.03

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3330.72

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

13179.12

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

80.06

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1539.95

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

299.76

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

71.04

-

-

... More
13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

1539.95

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

103.65

-

-

... More
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

74.63

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

77.64

-

-

... More
10.26.2:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.E.R.W. tubes

236.49

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

1296

-

-

... More
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover

6.3

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

99.46

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

71.04

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

22.08

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2.1

-

-

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

4.42

-

-

... More
OD244710/2022-2023:Supply and fixing 3 Ton capacity Gantry crane suitable for carrying chlorine cylinder including all fixing charges.

1

-

-

... More
2LL OHSR

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

225

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

225

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

62.27

-

-

... More
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

87.24

-

-

... More
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

58.06

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

55.3

-

-

... More
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

8.46

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

184.02

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.88

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

247.23

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

246.02

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

205.21

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

17.05

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

241.5

-

-

... More
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

65.66

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

5.48

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

29.19

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

107.54

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

54.45

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3516.24

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

15964.48

-

-

... More
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

5

-

-

... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

4.39

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

492.13

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

542.42

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

692.82

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

320

-

-

... More
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

1504.23

-

-

... More
22.4.3:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Kickers (320 mm wide, 5 mm thick)

35

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

144.99

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

80.19

-

-

... More
100.31.2.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class II.

1

-

-

... More
100.31.2.10:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 450mm diameter, Class II.

2

-

-

... More
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.

2

-

-

... More
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.

2

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

2

-

-

... More
100.98.437:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 100mm.

2

-

-

... More
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.

2

-

-

... More
100.98.463:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm.

1

-

-

... More
100.98.466:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm.

2

-

-

... More
18.30.7:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe

4

-

-

... More
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe

4

-

-

... More
18.30.11:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:500 mm diameter pipe

4

-

-

... More
18.30.12:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:600 mm diameter pipe

4

-

-

... More
OD185422/2023-2024:Supplying 450 mm electromagnetic flow meter conforming to protection level IP-68 for flow sensor and Ip-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. the flow meter should have the housing (flow meter) to be made of SS 304/ Carbon steel with anti corrosive protection and inside liner to be made up of hard ribber/ newsprint all conforming to drinking water standards. the flow meter should be coupled with HART for data acquisition and transfer, with provision for wire less transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. set 1.00000 210000.00 210000.00 Rate as per circular No:KWA/HO/SP-4014/2012/flow meter and soft starter dt.05.09.2012

2

-

-

... More
OD185424/2023-2024:Supplying and fixing water level guage on the side wall of water tank using 20mm guage MS plate welded to MS angle,standard scale in black paint on white background surface of MS plate at 5cm intervals to read from 0 to3.50m, Hanging indicator one end pointed painted in red tied o a steel rope moving smoothly over the pulley fixed on top of cover slab and ball arrangement fitted to other end of the steel rope placed inside the perforated PVC pipes 160mm dia 8kg/cm2 inside the water tank including all cost of materials, labour charges etc,m complete.

1

-

-

... More
OD185425/2023-2024:Supplying and fixing lightening arrester to OHSR by providing 1No. copper spike at the top of tank, clamping 20x3mm aluminium strip along horizontal run and 25x3mm aluminium strip along vertical run using GI fabricated clamps the spacing of clamp not exceeding 1m,rivetting,sweasing and soldering each end of aluminium tape using 2Nos.6mm dia GI bolts nuts, revets including drilling holes etc., and providing 4Nos.of earting on 40mm dia GI pipe,each 3m long including construction of masonry trough with cover slab, watering filling, with charcoal/coke, slat etc., as per IE rules and IS specification etc., complete.

1

-

-

... More
18.73.5:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :300 mm dia Ductile Iron Double Flanged

10

-

-

... More
18.73.8:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :450 mm dia Ductile Iron Double Flanged

20

-

-

... More
18.73.9:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :500 mm dia Ductile Iron Double Flanged

10

-

-

... More
18.73.10:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :600 mm dia Ductile Iron Double Flanged

10

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

27.81

-

-

... More
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia

2.71

-

-

... More
18.24:Laying in position S & S or flanged C.I. special such as tees, bends, collars, tapers and caps etc. ( excluding cost of specials).

8

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

375.02

-

-

... More
Construction of 9 LL SUMP cum Booster at Athithattu

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

625

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

1200.91

-

-

... More
2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

484.36

-

-

... More
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

124.23

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

522.36

-

-

... More
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

84.74

-

-

... More
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

2.1

-

-

... More
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

4.13

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

58.84

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

300.48

-

-

... More
5.34.1:Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

200.29

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

243.26

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

246.27

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

880.47

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

303.33

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

12.22

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

195.58

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

8214.16

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

37925.51

-

-

... More
22.4.3:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Kickers (320 mm wide, 5 mm thick)

114.16

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

3113.89

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

532.51

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1836.11

-

-

... More
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

333.22

-

-

... More
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

375

-

-

... More
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.

900

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

360

-

-

... More
OD244713/2022-2023:Supplying 600 mm electromagnetic flow meter conforming to protection level IP-68 for flow sensor and Ip-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. the flow meter should have the housing (flow meter) to be made of SS 304/ Carbon steel with anti corrosive protection and inside liner to be made up of hard ribber/ newsprint all conforming to drinking water standards. the flow meter should be coupled with HART for data acquisition and transfer, with provision for wire less transfer through GSM. The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. set 1.00000 210000.00 210000.00 Rate as per circular No:KWA/HO/SP-4014/2012/flow meter and soft starter dt.05.09.2012

1

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

1500

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

4

-

-

... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

61.16

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

91.72

-

-

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

7.86

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

7.44

-

-

... More
21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

45

-

-

... More
21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

25.57

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

14.36

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.04

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

1104

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

27.6

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

142.74

-

-

... More
16.1:Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

48

-

-

... More
16.78.3:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

7.33

-

-

... More
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

36.67

-

-

... More
18.73.10:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :600 mm dia Ductile Iron Double Flanged

15

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

56.82

-

-

... More
18.73.6:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :350 mm dia Ductile Iron Double Flanged

20

-

-

... More
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.

2

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

1

-

-

... More
100.98.437:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 100mm.

1

-

-

... More
100.31.1.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class I.

2

-

-

... More
100.31.1.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class I.

1

-

-

... More
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.

1

-

-

... More
100.37.23.1:In situ fabrication of M.S. pipes of size 750mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

14

-

-

... More
100.37.23.2:Fabricating M.S. flanges of diameter 750mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.

25

-

-

... More
100.37.23.3:Cutting 750mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

25

-

-

... More
100.37.23.4:Welding 750mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

25

-

-

... More
100.37.23.5:Grinding cut and weld edges of 750mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

50

-

-

... More
100.37.20.1:In situ fabrication of M.S. pipes of size 500mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

10

-

-

... More
100.37.20.2:Fabricating M.S. flanges of diameter 500mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 10mm thick M.S. plates.

5

-

-

... More
100.37.20.3:Cutting 500mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

15

-

-

... More
100.37.20.4:Welding 500mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

15

-

-

... More
100.37.20.5:Grinding cut and weld edges of 500mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.

30

-

-

... More
OD164664/2023-2024:Supply, fabrication and erection of long travel (LT) girder fixing to the base plate at the existing bracket at site including cutting hoisting and fixing in position and painting the exposed surface with a coats of steel primer and 2 coats of aluminum paint including cost of labour charges and conveyance of all materials, etc. complete and as directed by the departmental officers .

2214.82

-

-

... More
OD164662/2023-2024:Erection and commissioning of the above specified 3T capacity electrically operated over head crane arrangements suitably positioned on the appropriate ISMB steel sections including providing and fixing suitable side 45 x 45 MS base plate 18mm thick over the existing RCC pillars brackets by drilling, fixing belt of suitable size and grouting with CM and welding LT girder ISMB 550 with cover plate 20mm thick and also fixing the ends of the LT girder to the size suitably and also providing LT rail ISMB 250 with suitable end stoppage. This also includes provision for box type fabricated from rolled steel section and carriages of suitable construction with all good quality accessories like gears, wheels axis rubber buffers, bearing etc, the work also consists of all tools and equipment's , labour, supervision, load testing all safety devices required for the satisfactorily operation etc.. The rate inclusive of MS base plate, stoppers and carriage, all required accessories, painting with aluminum paints including trial run etc. complete

1

-

-

... More
OD164663/2023-2024:Design manufacture supply of 3T capacity electrically operated over head crane arrangements suitably positioned on appropriate ISMB steel sections used as main girders, carbon steel for pathway railing and grooved wheels. The entire assembly shall be capable for three dimensional lifting operations covering the entire transformer yard area. The whole mechanism must be easily operated from the tranformer yard floor and all the rotating parts shall be fitted with suitable bearings of international quality. The collinear transmission shall incorporated if any shall be jointed with steering cross and rivets. The gear box and transmission arrangements of the crane must be designed for smooth and easier operations. The motors and other electrical fitting connected with the crane shall be comply to relevant Indian Standards. All necessary safety arrangements shall be incorporated in the crane arrangements such as stoppers, overhead protection, earthling etc. The entire installations shall be painted using aluminum paint after two priming coat. An operation manual of the same also be supplied. The trolley frame shall be steel box sections and axial bearing shall be superior roller type. Wheel assembly should be fitted in L type housing and trolley wheel shall be medium carbon alloy steel solid forged with BHN 341. All gear boxes shall be completely enclosed having splash lubricated type scaled with neoprene O ring

1

-

-

... More
OD198767/2023-2024: Conveying and laying 750 mm MS pipe excluding cost of pipe and specials:

14

-

-

... More
OD198768/2023-2024: Conveying and laying 500 mm MS pipe excluding cost of pipe and specials:

10

-

-

... More
pumping main from Sump to Balancing OHSR - cost of pipe

-

-

-

... More
100.98.123:Supply of DI K9 Pipe Conforming to IS 8329/2000, 500mm Dia.

75

-

-

... More
OD190760/2023-2024:Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 500mm.

1

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

2

-

-

... More
pumping main from Sump to Balancing OHSR - working charge

-

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

52.2

-

-

... More
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.

69.6

-

-

... More
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

52.2

-

-

... More
100.14.9:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 500mm diameter Ductile Iron Class K-9 Pipes.

75

-

-

... More
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.

2

-

-

... More
18.30.11:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:500 mm diameter pipe

4

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

9.27

-

-

... More
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia

1.2

-

-

... More
100.31.2.11:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 500mm diameter, Class II.

1

-

-

... More
100.35.9:Testing 500mm DI/CI pipeline with potable water to the required test pressure. 500 mm dia Observed Data derived from item no.1028 of PHED DATA

75

-

-

... More
18.70.9:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:500 mm dia pipes

13

-

-

... More
OD190868/2023-2024:Labour for cutting DI. pipe with steel saw.500 mm diameter DI pipe

5

-

-

... More
600mm Raw water Pumping Main from Intake well to Booster at Athithattu- COST OF MATERIALS

-

-

-

... More
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.

2300

-

-

... More
OD244702/2022-2023:600mm CI Non return valve P N 1.6 confirming to relevent IS

3

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

1

-

-

... More
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.

5

-

-

... More
100.98.452:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 150mm.

5

-

-

... More
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.

2

-

-

... More
600mm Raw water Pumping Main from intake well to Booster at Athithattu- WORKING CHARGES

-

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

4242.35

-

-

... More
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.

1212.1

-

-

... More
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

606.05

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

1380

-

-

... More
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.

920

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

55.29

-

-

... More
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia

11.96

-

-

... More
18.30.12:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:600 mm diameter pipe

10

-

-

... More
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.

2300

-

-

... More
18.70.10:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes

500

-

-

... More
OD244707/2022-2023:Labour for cutting DI pipe with steel saw.600 mm diameter DI pipe

60

-

-

... More
100.35.10:Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA

2300

-

-

... More
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.

4

-

-

... More
100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II.

2

-

-

... More
100.32.6:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 150mm Double Acting Air Valve.

5

-

-

... More
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.

5

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

85.94

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

128.72

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

152.93

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

580.95

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

8325.82

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

11

-

-

... More
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

134

-

-

... More
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

12

-

-

... More
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

134

-

-

... More
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

134

-

-

... More
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

268

-

-

... More
OD249788/2022-2023:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) MS Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 600mm diameter MS pipe

134

-

-

... More
OD244708/2022-2023:Providing entry and exit pits for push through arrangement across BM and BC road /railway crossing(Earth work,steel shoring and bailing out water but excluding cost of pipe.

2

-

-

... More
OD244709/2022-2023:Providing 600mm dia push through arrangement and drilling with horizontal directional drilling machine and its air compressor for the work including all cost of moblization, installation and all labour charges etc.complete -but excluding cost of pipe

20

-

-

... More
100.37.18.1:In situ fabrication of M.S. pipes of size 900mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

20

-

-

... More
100.37.18.3:Cutting 900mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

4

-

-

... More
100.37.18.4:Welding 900mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

16

-

-

... More
100.37.18.5:Grinding cut and weld edges of 900mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

16

-

-

... More
OD188989/2023-2024:Conveying and laying MS pipes conforming to IS: 1536, excluding cost of pipe and specials: 900mm diameter pipes.

20

-

-

... More
600mm Raw water Pumping main from Booster at Athithattu to Tratment plant- COST OF MATERIALS

-

-

-

... More
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.

1200

-

-

... More
OD244721/2022-2023:Supplying Cast Steel 600mm dia D/F Non Return Valve

2

-

-

... More
100.98.464:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm.

1

-

-

... More
100.98.452:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 150mm.

2

-

-

... More
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.

2

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

1

-

-

... More
600mm Raw water Pumping main from Booster at Athithattu to Tratment plant- WORKING CHARGE

-

-

-

... More
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.

2213.4

-

-

... More
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.

632.4

-

-

... More
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

316.2

-

-

... More
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.

180

-

-

... More
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.

180

-

-

... More
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia

47.67

-

-

... More
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia

9.48

-

-

... More
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.

1200

-

-

... More
18.70.10:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes

260

-

-

... More
18.30.12:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:600 mm diameter pipe

10

-

-

... More
OD244714/2022-2023:Labour for cutting DI pipe with steel saw.600 mm diameter DI pipe

30

-

-

... More
100.35.10:Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA

1200

-

-

... More
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.

3

-

-

... More
100.32.6:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 150mm Double Acting Air Valve.

2

-

-

... More
100.31.2.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class II.

1

-

-

... More
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.

2

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

52.1

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11.37

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

134.59

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

408.58

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6203.3

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

6

-

-

... More
100.37.14.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.

20

-

-

... More
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.

2

-

-

... More
100.37.14.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

20

-

-

... More
100.37.14.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

20

-

-

... More
100.37.14.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.

40

-

-

... More
OD16275/2023-2024:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron/MS Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes./ MS pipes

20

-

-

... More
Supply and Errection of 3 nos of 55 HP centrifugal pumpset for clear water pumping from Sump at WTP to Balancing OHSR

-

-

-

... More
OD182995/2023-2024:Supply, errection, testing and commissioning of reputed make 55 HP Centrifugal pump with all accessories from the approved manufactures of KWA meeting the Technical specifications with all accessories including 2 years warranty from the date of commissioning , fully auotomatic Star delta Starter with air break contact suitable for the 55 HP motor with over voltage and under voltage protection, single phase preventer, overload relay with motor protection relay as per IE rules and code of practice etc complete and horizontal solid shaft foot mounted TEFC squrrel cage induction motor suitable for above pump working on 3phase 50HZ AC,Supply, working voltage 415V The motor shall confirm EEFI/IS 325 including providing suitable RCC foundation including cost of cement ,sand and metal etc complete. Flexible coupling shall be provided for coupling of pumps and motors. PANEL BOARD (with interlock suitable for operating three nos 55HP centrifugal pump sets but two pump set at a time)- consisting suitable capacity MCCB as incomer and suitable capacity MCCBs as outgoing providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with indicator lamps , voltmeter with selector switch , ammeter with selector switch , kw and pf meter for incomer and all outgoing and etc complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. CABLING WORK - Supplying, laying, testing and commissioning of suitable size XLPE cables for the above pumpset from main LT panel to motor panel board to starter and from starter to motor considering energy conservation. EARTHING - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. CAPACITOR - Supply , erection ,testing and commisioning of heavy duty APP capacitor for the motor to get a power factor above 0.98 & 1.0. The capacitor shall confirm to IS 2834 . The Duty Conditions of the pumpset: Total Head-27.58m. Total Discharge required : Not less than 179.43 LPS (For 2 Pumpsets running together) Dia of Pumping Main = 500 mm dia DI K9/MS Length of Pumping Main = 50 m Minimum Efficiency Required = 70% . Running Condition : 3 Pumpsets Connected in parallel, 2 running at a time one stand by.

3

-

-

... More
Supply and Erection of 3 Nos 250HP VT Pumpset for Raw Water Pumping at Intake Well

-

-

-

... More
OD182141/2023-2024:Supply ,Erection,Testing and Commissioning of 250 HP VT Pumpset from the approved manufactures of KWA meeting the Technical specifications with all accessories including 2 years warrenty from the date of commissioning, 3.3KV Soft Starter with air break contact with integrated bypass contactor and main power contactor, indicating display meter for kw, pf, V & I suitable for the 250 HP motor with over voltage and under voltage protection, single phase preventer, overload relay with motor protection relay as per IE rules and code of practice etc complete, vertical solid shaft TEFC squrrel cage induction motor suitable for above pump working on 3phase 50HZ AC,Supply, working voltage 3300V The motor shall confirm EEFI/IS 325 including providing suitable RCC foundation including cost of cement ,sand and metal etc complete, non reversible ratchet coupling shall be provided for coupling of pumps and motors, CABLING WORK - Supplying, laying, testing and commissioning of suitable size 3.3KV XLPE cables for the above pumpset from panel board to starter and from starter to motor considering energy conservation. EARTHING - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. CAPACITOR - Supply , erection ,testing and commisioning of 3.3kV heavy duty APP capacitor for the motor to get a power factor between 0.98 & 1.0 with suitable detuned inductor coil. The capacitor shall confirm to IS 2834 . The Duty Conditions of the pumpset : Total Head-105.36m. Total Discharge required : Not less than 235.13 LPS (For 2 Pumpsets running together) Dia of Pumping Main = 600 mm dia DI K9/MS Length of Pumping Main = 2300 m Minimum Efficiency Required = 70% Foot Valve level = +11.5, Inlet level of Booster= +113.5 Running Condition : 3 Pumpsets Connected in parallel, 2 running at a time one stand by.

3

-

-

... More
Supply & Errection of 3 nos 0f 190 HP centrifugal Pumpset for Raw Water Pumping Main at Athithattu Booster Station

-

-

-

... More
OD182429/2023-2024:Supply, errection, testing and commissioning of reputed make 190 HP Centrifugal pump with all accessories from the approved manufactures of KWA meeting the Technical specifications with all accessories including 2 years warranty from the date of commissioning, Soft Starter with air break contact suitable for the 190 HP motor with over voltage and under voltage protection, single phase preventer, overload relay with motor protection relay as per IE rules and code of practice etc complete and horizontal solid shaft foot mounted TEFC squrrel cage induction motor suitable for above pump working on 3phase 50HZ AC,Supply, working voltage 415V The motor shall confirm EEFI/IS 325 including providing suitable RCC foundation including cost of cement ,sand and metal etc complete. Flexible coupling shall be provided for coupling of pumps and motors. PANEL BOARD (suitable for operating three nos 190HP Centrifugal pump sets but two pump set at a time)- consisting suitable capacity MCCB as incomer and suitable capacity MCCBs as outgoing with suitble interlock mechanism, providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with indicator lamps , voltmeter with selector switch , ammeter with selector switch etc complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation CABLING WORK - Supplying, laying, testing and commissioning of suitable size XLPE cables for the above pumpset from panel board to starter and from starter to motor considering energy conservation. EARTHING - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. CAPACITOR - Supply , erection ,testing and commisioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 . The Duty Conditions of the pumpset : Total Head-78.73m. Total Discharge required : Not less than 235.13 LPS (For 2 Pumpsets running together) Dia of Pumping Main = 600 mm dia DI K9/MS Length of Pumping Main = 1200 m Minimum Efficiency Required = 70% . Running Condition : 3 Pumpsets Connected in parallel, 2 running at a time one stand by.

3

-

-

... More
Transformer Room

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

108.5

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

52.5

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

13.87

-

-

... More
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

13.87

-

-

... More
100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.

6.94

-

-

... More
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

4.2

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

32.5

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

54.24

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

106.38

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

63.4

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

50.4

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

6.81

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

10.81

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

31.18

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1297.51

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

3741.17

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

412.4

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

72.73

-

-

... More
13.45.1:Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

466.15

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

51.24

-

-

... More
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover

6.3

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

39.38

-

-

... More
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

29.84

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

12.19

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

630

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

19.69

-

-

... More
6.47:Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

3.05

-

-

... More
Compound wall for WTP

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

306.96

-

-

... More
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.69

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

244.86

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

8.4

-

-

... More
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level

0.63

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

0.74

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

37.68

-

-

... More
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

44.1

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

271.2

-

-

... More
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

300

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

1333.79

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

1333.79

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

7.5

-

-

... More
4.1.13:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1: 21/2:4:11 (1 Ordinary portland cement : 21/2 fly ash: 4 coarse sand : 11 graded stone aggregate 40 mm nominal size)

24

-

-

... More
16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

450

-

-

... More
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

80

-

-

... More
7.2.1:Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

180

-

-

... More
30.2.12:Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.

200

-

-

... More
Internal roads for WTP

-

-

-

... More
3.15.2:Compacting Original Ground (ii) Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

225

-

-

... More
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material

112.5

-

-

... More
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

112.5

-

-

... More
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

750

-

-

... More
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.

750

-

-

... More
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)

750

-

-

... More
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)

750

-

-

... More
Transformer 200KVA

-

-

-

... More
OD183829/2023-2024:Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint, including earthing etc complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards

1

-

-

... More
OD183850/2023-2024:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat, earthing as per IS, Including laying of broken granite agregate in the yard area as per IS.

60

-

-

... More
OD183917/2023-2024:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.

2

-

-

... More
OD190574/2023-2024:Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: Current Transformer, CT Ratio 100/5A, Burden 15VA, Accuracy Class 0.2S, Potential Transformer, PT ratio 11KV/110V, Burden -100VA, Accuracy Class 0.2, The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.

1

-

-

... More
OD183959/2023-2024:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk.The rate shall include the cost of inter connection cable to CTPT and testing the equipment at KSEB and all other incidental expences

1

-

-

... More
OD183968/2023-2024:Supply, erection, testing and commissioning of 200 KVA, 11KV/433V. 3phase, 50Hz. ONAN cooled , outdoor type copper wound distribution transformers with HV side3 bushing and LV side cable end box arrangements, off load tap changer with 5 tap positions having +5% to -5% variations in 2.5% steps including first filling of oil, neutral earthing,transformer earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards

1

-

-

... More
OD183975/2023-2024:Design,engineering, supply erection,testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight &amp; vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, pvc sleeved, air insulated and of adequate size as mentioned below, for operation on 3 phase, 4wire, 415volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti &ndash;rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. 3phase 4 wire 300A Aluminium Bus Bar with copper earth bus Incomer 400A 4pole MCCB Out going : 160A 4 pole MCCB - 1 No, 100 A 4 pole MCCB -3nos, 63A 4 pole MCCB-2 Nos

1

-

-

... More
OD184033/2023-2024:Lighting Panel: Supply, erection, testing and commissioning of MCCB distribution board comprising to the following. 63A 4 pole MCCB 1 No. as incomer with 63A 100mA RCCB and 32A 4P MCCB-3Nos. as outgoings, With 100A Al busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards.

1

-

-

... More
OD184046/2023-2024:Supply laying terminating with double compression brass cable glands testing and commissioning of 3.5 core 50sqmm armoured aluminium XLPE cable ( for LT Panel to Lighting panel)

20

-

-

... More
OD190637/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.Cables of various sizes as per scheme sanctioned by Ele Inspector 3.5core 300sqmm 1100v

50

-

-

... More
OD190652/2023-2024:Supply of all materials and providing end termination using double compression brass cable glands of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts grade ) for giving power connections to Transformers, Panel boards etc. complete as per standards. 3.5core 300sqmm 1100v

2

-

-

... More
OD190660/2023-2024:Supply Installation and testing and commissioning of platee earthing with GI plate electrode 600mm x 600mm and 6 mm thickness - the platee electrode being first fabricated and then galvanized to minimum 100 microns coating thickness, with no bare steel surface left exposed without zinc coating &ndash; the installation done as per IS at 3.0M depth at the earthing location, with the connection terminal on the top of the plate electrode above the ground level, and then backfilling watering and compaction using excavated earth mixed with conductivity enhances and moisture retention agents including construction of masonry trough with MS cover as per IS 3043 - 1987.As per earthing design approved by Ele Inspector

10

-

-

... More
OD190672/2023-2024:Supply, laying and termination of the various sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x6mm copper strip

50

-

-

... More
OD190683/2023-2024:25x3mm copper strip

100

-

-

... More
OD190687/2023-2024:No. 8 swg copper wire

100

-

-

... More
OD190695/2023-2024:No10swg copper wire

50

-

-

... More
OD184263/2023-2024:Supply and fixing of 6mm thick checkered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.

0.3

-

-

... More
OD184268/2023-2024:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, &amp; trusses etc. as per KEI standards.

0.3

-

-

... More
OD184270/2023-2024:Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards. Fire bucket with stand, HT & LT Danger board, HT gloves, Insulation floor mat, Dry powder chemical fire extiguisher, CO2 fire extinguisher etc as required.

1

-

-

... More
OD184272/2023-2024:Preparation of scheme drawing , getting scheme approval , coordinating statutory inspections and getting energisation sanction from Electrical Inspectorate and KSEBL

1

-

-

... More
Electrification of transformer building , pump house and Booster Station

-

-

-

... More
OD183506/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, &ldquo;C&rdquo; curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole. (DELHI ANALYSIS OF RATES (E&amp;M) 2018- 2.10.1 + Cost Index 33.9%

18

-

-

... More
OD183498/2023-2024:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire

210

-

-

... More
OD183512/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate &amp; switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (PRICE3 DAR ELECTRICAL 1.24.4) +Cost Index: 33.9%

14

-

-

... More
OD183528/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate &amp; switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet (PRICE 3 DAR ELECTRICAL 1.24.5 + Cost Index 33.9%

6

-

-

... More
OD183675/2023-2024:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep (PRICE 3 DAR ELECTRICAL 1.50.1) +Cost Index 33.9%

20

-

-

... More
OD183686/2023-2024:Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B + Cost Index : 33.9 %

91

-

-

... More
OD183695/2023-2024:Supply installation testing and commissioning of indoor industrial surface mounted LED tube and batten along with driver , surge protector,system wattage of 20+/-2 Watts,lumen output of lamp greater than 1600lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 70lumen/watt and including all necessary accessories as required complete

44

-

-

... More
OD183699/2023-2024:Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C

10

-

-

... More
OD183705/2023-2024:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (PRICE 3 DAR ELECTRICAL 1.25) + Cost Index: 33.9%

10

-

-

... More
OD183717/2023-2024:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door. DELHI ANALYSIS OF RATES (E&amp;M) 2018 - 2.4.3 + Cost Index: 33.9%

2

-

-

... More
OD183725/2023-2024:Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required .(DELHI ANALYSIS OF RATES (E&amp;M) 2018 -1.34 + Cost Index 33.39%

2

-

-

... More
OD183727/2023-2024:Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C (PRICE 3 DAR ELECTRICAL 1.3.3) + Cost Index 33.9%

20

-

-

... More
OD183736/2023-2024:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required- 63 A . (DELHI ANALYSIS OF RATES (E&amp;M) 2018) - 2.13.2. + Cost Index : 33.9%

2

-

-

... More
OD183752/2023-2024:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A

2

-

-

... More
OD183756/2023-2024:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire . (PRICE 3 DAR ELECTRICAL 1.7.7)+ Cost Index : 33.9%

50

-

-

... More
OD183763/2023-2024:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. (DELHI ANALYSIS OF RATES (E&amp;M) 2018-1.33) + Cost Index 33.9 %.

111

-

-

... More
OD183765/2023-2024:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DELHI ANALYSIS OF RATES (E&amp;M) 2018-5.4) +Cost Index : 33.9%

5

-

-

... More
OD183770/2023-2024:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door.( DELHI ANALYSIS OF RATES (E&amp;M) 2018 ). + Cost Index : 33.9%

1

-

-

... More
OD183776/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps.(DELHI ANALYSIS OF RATES (E&amp;M) 2018 -2.12.1 ) + Cost Index 33.9%

1

-

-

... More
OD183791/2023-2024:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A. (DELHI ANALYSIS OF RATES (E&amp;M) 2018 -2.14.2) + Cost Index: 33.9%

1

-

-

... More
OD183793/2023-2024:Street light fitting with 20W LED street light with asymetric beam angle 130X50 degree with luminiare efficiency more than 851m/W rugged aluminium alloy housing with all accessories complete (OSRAM STRADA plus 20W 6500K , Lumen/Watt &gt;80 or eqivalent )

14

-

-

... More
630 KVA Transformer

-

-

-

... More
OD244723/2022-2023:11KV Equipments Supply of all materials and providing 11KV sub station yard using 2nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms,1set of 200A, 11KV gang operated AB switches with operating handles of required length,1 set of 9.6KV,6KA , Lightning Arrestors, 1set of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using ACSR conductor with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards

1

-

-

... More
OD244724/2022-2023:Supply of all materials and providing sub stattion yard fencing using 50x50x6mm angle iron (br) frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 (br) 50x6mm vertical channel erected at 1500mm c/c and 2500mm above ground level of sub (br) station yard and 500mm below with 300x300mm plain cement concrete (1:3:6 )base using 40 (br) mm granite aggrigate and top surface finished neat and including all associated civil works and (br) painting of all structures with 2 coats of zinchromate primer and aluminium paint etc.complete (br) as per standard construction practises approved by kerala electrical inspectorate and relevent (br) standard (br).

45

-

-

... More
OD244725/2022-2023:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of (br) 50 x 50 x 6mm Angles with necessary foundation locking relevent standard arrangements etc.<br> complete, including painting with two coats of zinchromate primer and aluminium paint as per<br>standards, <br>

2

-

-

... More
OD244726/2022-2023:11KV Metering Unit Supply,erection, testing and commissioning of indoor door type metering unit consisting of the following accessories: Current Transformer CT Ratio 50/5A Burden 15VA Accuracy Class 0.2S Potential Transformer PT ratio 11KV/110V Burden -100VA. Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences .The CT ratio should be fixed only after obtaining the power allocation from KSEB,

1

-

-

... More
OD244727/2022-2023:TOD Meter Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences.

1

-

-

... More
OD244728/2022-2023:11KV VCB Switch gear(Indoor) Supply, erection, testing and commissioning of 11KV, 630A, 350MVA,totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker four panel system (1 no. VCB as incomer and 2 nos.VCBs & 1 no SFU as outgoings) suitable for installation in 3 phase , 3wire, 50Hz AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering<br>equipments, protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel Including provision for installing indoor type 11KV Metering CT and PT and , TOD meter with locking and sealing facility but excluding cost of CT, PT And TOD meter

1

-

-

... More
OD244729/2022-2023:11 KV/433 V, 630 KVA Cast Resin Transformer(Indoor) Supply, erection, testing and commissioning of 630 KVA, 11KV / 433V, 3 Phase, 50 Hz, Self cooled (Air Natural) Cast Resin dry type, step down double Copper Wound indoor distribution Transformers having Delta winding on primary and star winding on secondry with Dyn11 vector group connection having neutral brought out on star side with off Circuit tapping 5 % to - 5 % Insteps of 2.5 % with suitable cable box on HT & LT side confirming to IS2026/1977 and IS11771 / 1985. Including supply erection testing and commissioning of neutral CT in weather proof enclosure and control cables.

1

-

-

... More
OD190674/2023-2024:Design,engineering, supply erection,testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight &amp; vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, pvc sleeved, air insulated and of adequate size as mentioned below, for operation on 3 phase, 4wire, 415volts, 50Hz. AC supply system. Display meters for V, I, KW, pf of reputed make.The MCCBs, all meters and relays etc. should be reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti &ndash;rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. 3phase 4 wire 1000A Aluminium Bus Bar with copper earth bus Incomer 1000A 4pole MDO 50 kA ACB with 3O/C, E/F & REF protection Out going : 500 A 4 pole 50kA MCCB -2nos 63A 4 pole MCCB-2 Nos

1

-

-

... More
OD244733/2022-2023:Lighting Panel: Supply, erection, testing and commissioning of MCCB distribution board comprising to the following. 63A 4 pole MCCB 1 No. as incomer with 63A 100mA RCCB and 32A 4P MCCB-3Nos. as outgoings, With 100A Al busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards.

1

-

-

... More
OD244735/2022-2023:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed<br>armoured Aluminium conductor cable (1100 volts& 11kv grade) clamped on wall/ceiling with<br>clamps and saddle clips partly laid in cable tray/partly laid in trench.<br>3 core 150Sq.mm.11kv, XLPE AL cable

80

-

-

... More
OD244737/2022-2023:3.5 core 400 Sq.mm AYFY Cable 1100 V

200

-

-

... More
OD244738/2022-2023:3.5 core 50 Sq.mm AYFY Cable 1100V

30

-

-

... More
OD190858/2023-2024:3 core 185Sq.mm. AYFY Cable 1100 V

100

-

-

... More
OD244740/2022-2023:4 core 10Sq.mm PVC AL. Cable <br>

40

-

-

... More
OD244741/2022-2023:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 150Sq.mm.11kv,XLPE AL Cable( indoor & outdoor)

4

-

-

... More
OD244742/2022-2023:3.5 core 400 Sq.mm AYFY Cable

16

-

-

... More
OD244743/2022-2023:3.5 core 50sq.mm AYFY Cable

2

-

-

... More
OD244745/2022-2023:3 core 185Sq.mm. AYFY Cable

8

-

-

... More
OD244746/2022-2023:4 core 10 sq.mm PVC AL. cable

6

-

-

... More
OD190779/2023-2024:EARTHING - Supply and providing plate earhing as per IS 3043 by using 600mm x 600mm x 3mm thick copper plate with 2.7mtrs. Long 20mm dia 'B' class GI watering pipe extended upto middle of copper plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earh bus with copper plate by using 2 nos. 25x6mm copper strip of suitable length, filling charcoal and salt at alternate intervels of 15cm all aournd Copper plate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI chamber cover etc. complete.

11

-

-

... More
OD244748/2022-2023:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x6mm copper strips.

50

-

-

... More
OD244749/2022-2023:25x3mm copper strips.

100

-

-

... More
OD244750/2022-2023:25x6mm GI strips

50

-

-

... More
OD244751/2022-2023:32x6mm GI strips

20

-

-

... More
OD244752/2022-2023:MS Items.Supply and fixing of 6mm thick checkered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted<bone coat of primer and two coats of enamel paint as required

0.3

-

-

... More
OD244754/2022-2023:Battery& Battery Charger. Supplying, fixing, testing and commissioning of Lead acid cell battery 24V, 200AH capacity at<br>10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell,<br>inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc<br>with electrolyte of specific gravity 1.190 and accessories such as voltmeter, Thermometer,<br>Hydrometer, spaners etc with teak wood stand with 3 coats of antiacid paint to accomodate<br>battery.<br>

1

-

-

... More
OD244755/2022-2023:Supplying fixing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc complete as per standards

1

-

-

... More
OD244756/2022-2023:safety items , supply and providing the following safety items approved by Kerala electrical inspectorate and relevent standards .

1

-

-

... More
OD190812/2023-2024:Provision for soil resistivity measurement , earthing design, making electrical scheme drawing and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA)

1

-

-

... More
750 KVA 11/3.3KVtransformer

-

-

-

... More
OD184691/2023-2024:Supply of all materials and providing 11KV sub station yard using 4nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. MS chanel cross arms, 2sets of 200A, 11KV gang operated AB switches with opertating handles of required length,2 sets of 9.6KV,6KA , Lightning Arrestors, 2sets of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint, including earthing etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards

1

-

-

... More
OD184905/2023-2024:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished nea,t earthing as per IS Including laying of ganite agregate in entinre yard area as per IS

60

-

-

... More
OD184696/2023-2024:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.

2

-

-

... More
OD184698/2023-2024:Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: Curtrent transformer -CT Ratio 100/5A,Burden 15VA-,Accuracy Class 0.2S, Potential Transformer- PT ratio 11KV/110V, Burden -100VA-Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB.

1

-

-

... More
OD184700/2023-2024:Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences.

1

-

-

... More
OD184701/2023-2024:Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker four panel system (1 no. VCB as incomer and 2 nos.VCBs & 1 no SFU as outgoings) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and all metering equipments for indicating V, I, KWA, P Fetc, protective relays etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.

1

-

-

... More
OD185665/2023-2024:Supply, erection, testing and commissioning of 3.3KV, 400A, 75MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type panel board comprising of two nos.Vacuum Circuit Breaker as incomers, one no. VCB as bus coupler and 5 nos. Vacuum Contactors as outgoings. The incomer switchgears, bus coupler & outgoing switchgears should be of drawout type trip free VCBs suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, suitable for parellel operation, trip free closing mechanisum and all metering equipments indicating V, I ,KW, PF, numerical protective relays of reputed make, etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel.

1

-

-

... More
OD184702/2023-2024:Supply,erection, testing and commissioning of 750 KVA, 11KV/3.3KV. 3phase, 50Hz. ONAN cooled , indoor type copper wound distribution transformers, suitabe for parrallel operation, with HV and LV side cable end box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with RTCC panel including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.

1

-

-

... More
OD184703/2023-2024:Supply, erection, testing and commissioning of 100 KVA, 11KV/433V. 3phase, 50Hz. ONAN cooled , indoor type copper wound distribution transformers with HV and LV side cable end box arrangements, off load tap changer with 5 tap positions having +5% to -5% variations in 2.5% steps including first filling of oil etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards

1

-

-

... More
OD184909/2023-2024:Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR.

1

-

-

... More
OD184740/2023-2024:Design,engineering, supply erection,testing and commissioning of medium voltage sheet steel clad, totally enclosed, dust tight & vermin proof, indoor floor mounted cubicle type switchboard fabricated out of 14swg mild steel sheet, and bus duct of high conductivity aluminium bus bars, pvc sleeved, air insulated and of adequate size as mentioned below, for operation on 3 phase, 4wire, 415volts, 50Hz. AC supply system. The MCCBs, all meters and relays etc. should be reputed make and conforming IS specifications and are assembled, interconnected, earthed and the switch board should be painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards. Main switch board 100A TPN bus bars of suitable sizes: Earthing conductor: 25x3mm copper. 100A 35kA, 4 pole MCCB with 3 O/C & 1 E/F release set at 100A 63 A TP MCCB, 1No & 32 A TP MCCB, 3 Nos. as outgoings Metering compartments comprising of voltmeters, ammeters, selector switches, Numerical protection relays, energy meter, indicating lamps etc. complete. as per KEI standards.

1

-

-

... More
OD184742/2023-2024:Supply,erection, testing and commissioning of 8 way TPN MCB distribution board comprising to the following. 63A 4 pole MCB 1 No. as incomer with 63A 100mA ELCB and 20A TP MCB-2Nos. & 6A SP MCB- 10 Nos each. as outgoings, With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system.

1

-

-

... More
OD184744/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.

20

-

-

... More
OD184943/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3 core 150Sq.mm.11kv, XLPE AL Cable

60

-

-

... More
OD184948/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3 core 185 Sq.mm,3.3kV XLPE AL Cable.

250

-

-

... More
OD184951/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 3.5 core 50Sq.mm. AYFY Cable

40

-

-

... More
OD184964/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench. 4 core 16 Sq.mm.PVC AL. Cable.

20

-

-

... More
OD184970/2023-2024:Supply, laying, testing and commissioning of size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts&3.3/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench.

20

-

-

... More
OD184913/2023-2024:Supply of all materials and providing end termination of size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 1 core 95 Sq.mm.3.3kv,XLPE AL Cable(Indoor)

2

-

-

... More
OD184919/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 150 Sq.mm.11kv,XLPE AL Cable (Indoor)

5

-

-

... More
OD184915/2023-2024:Supply of all materials and providing end termination of size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 150Sq.mm.11kv,XLPE AL Cable(Outdoor)

1

-

-

... More
OD184922/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3core 185 Sq.mm.3.3KV XLPE AL Cable.

18

-

-

... More
OD188008/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3.5core 95 Sq.mm.PVC AL. Cable.

4

-

-

... More
OD188331/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 4 core 16 Sq.mm.PVC AL. Cable.

2

-

-

... More
OD184932/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 4 core 10 Sq.mm.PVC AL. Cable.

2

-

-

... More
OD188358/2023-2024:EARTHING - Supply and providing plate earhing as per IS 3043 by using 600mm x 600mm x 3mm thick copper plate with 2.7mtrs. Long 20mm dia 'B' class GI watering pipe extended upto middle of copper plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earh bus with copper plate by using 2 nos. 25x6mm copper strip of suitable length, filling charcoal and salt at alternate intervels of 15cm all aournd Copper plate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI chamber cover etc. complete.

11

-

-

... More
OD184750/2023-2024:Supply, laying and termination of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 32x6mm GI strips.

400

-

-

... More
OD184751/2023-2024:Supply, laying and termination of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x6mm Copper strips.

300

-

-

... More
OD184752/2023-2024:Supply, laying and termination of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x3mm copper strips.

200

-

-

... More
OD188375/2023-2024:Supply, laying and termination of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 8 SWG (4mm)copper wire

400

-

-

... More
OD185674/2023-2024:Supply and fixing of 6mm thick checkered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.

0.3

-

-

... More
OD185676/2023-2024:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.

0.3

-

-

... More
OD184794/2023-2024:Supplying, fixing, testing and commissioning of Lead acid cell battery suitable for operation of the switchgears and protective equipments with sufficient Ah capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific gravity 1.190 and accessories such as voltmeter, Thermometer, Hydrometer, spaners etc with teak wood stand with 3 coats of antiacid paint to accomodate battery.

1

-

-

... More
OD184795/2023-2024:Supplying, fixing, testing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc. complete as per standards.

1

-

-

... More
OD184797/2023-2024:Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.

1

-

-

... More
OD188392/2023-2024:Preparation of scheme drawing , getting scheme approval , coordinating statutory inspections and getting energisation sanction from Electrical Inspectorate and KSEBL

1

-

-

... More
Watchman cabin

-

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

48

-

-

... More
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

17.5

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

18.43

-

-

... More
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

4.61

-

-

... More
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

5.86

-

-

... More
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.23

-

-

... More
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

10.57

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1.05

-

-

... More
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

10.92

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

2.67

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

31.78

-

-

... More
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide

2.16

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

1.01

-

-

... More
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level

2.96

-

-

... More
11.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

6.45

-

-

... More
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

13.54

-

-

... More
9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.02

-

-

... More
9.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters

1.55

-

-

... More
9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

5

-

-

... More
9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

2

-

-

... More
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

16.88

-

-

... More
21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)

5.18

-

-

... More
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

4.57

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

116.5

-

-

... More
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete

29.32

-

-

... More
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

134.72

-

-

... More
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

279.6

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

8.74

-

-

... More
17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

1

-

-

... More
18.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore

2

-

-

... More
18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

-

-

... More
18.55.1:Providing and fixing PTMT stop cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms

1

-

-

... More
18.58.1.2:Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole

1

-

-

... More
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

1

-

-

... More
17.69.2:Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms

1

-

-

... More
17.70.1:Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

1

-

-

... More
50.18.8.1.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge. Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 12 Kgf/ cm2

7

-

-

... More
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

10

-

-

... More
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

2

-

-

... More
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

500

-

-

... More
SCADA and CCTV Installation works

-

-

-

... More
OD9391/2024-2025:Supply and installation of SCADA system and CCTV camara for 22 MLD WTP including the following features. 1. programming and commissioning PLC control panel with necessary switchgear 2. Measuring & Monitoring of Raw water flow, pH, Turbidity using necessary sensors. 3. Monitoring & Controlling of Alum and Lime Mixing Motor, generating alarms and reports in SCADA. 4.Monitoring & Controlling of Clariflocculator Motor, generating alarms and reports in SCADA. Measuring & Monitoring Filter Bed Level, generating alarms and reports in SCADA. 5. Controlling & Monitoring Filter Bed Raw water valves, Clear water Valves, Backwash and Air valves, generating alarms and reports in SCADA. 6. Measuring & Monitoring of Clear water flow, pH, Turbidity using necessary sensors, generating alarms and reports in SCADA. 7.Measuring & Monitoring of Chlorine level. 8. Measuring & Monitoring of Clear water Sump tank level. 9.Monitoring & Controlling of Back wash over head tank pump and Air lower for backwash, will be implemented and logged.

1

-

-

... More
Electrical equipments, electrification, fittings and fixuteres for WTP

-

-

-

... More
OD190299/2023-2024:Providing electromechanical components for flash mixer ,floculator,filter , recycling pump, wash water pump, clarifier etc complete and obtaining sanction from electrical inspectorate and approval from KSEB

1

-

-

... More
OD190798/2023-2024:Electrification charges,including wiring,panel board and all other electrical works as per approved detailed description of work and specifications as per the direction of Engineer in charge

1

-

-

... More
All charges for Mechanical Items

-

-

-

... More
OD244757/2022-2023:All charges for Mechanical items including supplying and fixing pipes,valves and specials,Instrumentation,supply of gauges,supply and installation of Blower unit and allied components compatible for SCADA operation and all fabrication works , under drainage system for filter beds, pumping main for recycling tank including cost, conveyance and labour charges etc. complete as per approved design, drawings and specifications .

1

-

-

... More
Panchayath road restoration

-

-

-

... More
3.2:Preparation of Foundation for Embankment Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

744

-

-

... More
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material

111.6

-

-

... More
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

111.6

-

-

... More
5.1.1a:Prime Coat :- Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

1240

-

-

... More
5.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.

1240

-

-

... More
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)

1240

-

-

... More
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)

1240

-

-

... More
Miscellaneous items & works

-

-

-

... More
OD246307/2022-2023:Supply and installation of following safety equipments and any other safety equipments being prescribed by inspectorate of Factories and Boilers from time to time for licensing of Water Treatment Plant as per the direction of Engineer in charge . 1. Breathing Apparatus of approved (ISI ) brand with air filled cylinder(reusable type), 30 mintes capacity -2 Nos 2. Fire extinguishers 5 kg capacity- 10 Nos 3. Hand Gloves - 10 Sets 4. Gum Boot - 10 Sets 5. Helmets - 10 sets 6. Hardhats - 10 Nos 7.Respiratory mask single filter - 5 sets 8.Hearing protection -5 sets 9. Emergency Chlorine cylinder handling tool kit - 1 set 10. Fire bucket (3 Nos) with stand, filled with sand -3 sets

1

-

-

... More
OD190806/2023-2024: Supply and installation of following laboratory equipments with specifications for WTP laboratory. PH METER -1 SET pH:-Range:0.000 to 14.000 ; Resolution: 0.1/0.01/0.001 pH ; Repeatability: t 0.003pH; Accuracy:t 0.003 pH ;Cal.Points 5 points; Butfer options: USA, NIST, Custom ORP:- Range:11999.9 mv; Resolution:0.1 mV; Repeatability:t 0.2mV; Accuracy:t 0.2mV ; Temperature: Range: 0.0 to 100"C; Resolution:0.1"C; Repeatability: 10.4'c ; Accuracy: tO.4"C ; Electrode specifi cation: Double junction toughened glass /unbreakable electrode with filling solution ; Shall provide ATC; Meter and electrode shall be of same manufacturer; Meter Features (irOff seuslope should be displayed ; (ii) Should have Data logging facility; (iiilOutput RS232/USB (iv)Memory 500 data sets minimum; (vlPower 230V 1107o; (vi)Buffer set : USA pH 4.01, 7.00, 10.01 minimum 100m1 each shall be supplied with the instrument; (vii) Should provide electrode filling solutlon (minimum 100m1) (viii)Should provide hard copy of user manual with instrument and electrode specification ; (ix) Compliance: GLP with test certificate of the instrument with traceability from the manufacturer. Values obtained for the pH 4.01 , 7.00 and 10.01 at 25 degree C shall b6 included in test report; (x) IQ/OQ/PQ documentation shall be provided (xi) CRM for calibration during PQ shall be supplied by KWA (xiil Should Supply non corrosive electrode stand. (Xiii) Warranty: 3 year for the Meter and 1 year for the electrode 2. TURBIDITY METER -1 set Measurement method: Nephelo metric method ; Range: 0 to 2000NTU, Auto range selection (Four ranges 0.01NTU to 19.99NTU with 0.01NTU resolution) 20.0NTU to 99.9NTU with 0.1NTU resolution, 100NTU to 2000NTU with 1NTU resolution ; Accuracy: <0.1NTU for 0.02NTU standard , + 2 °/» for reading, +1 digit for 0-500NTU + 3°/+ of reading, +1 digit for501-2000NTU or better; Repeatability: <+ 1°/+ of reading or better; Calibration: 4 points or more (auto selection); Light source: Infra red emitting diode 850 nano meter wave length ; Display type LCD; ISO 7027 Compliant ; Minimum turbidity 0.01NTU ; Operating temperature 0°Cto 50°C ; Shall provide calibration standards 0.02NTU, 20NTU, 100NTU and 800NTU (minimum 50 ml); Power: appropriate alkaline batteries (> 1000 readings) or 230V+/-10°» , 50Hz ;Cuvette : 3 nos minimum . Sample volume : 10ml . Water proof instrument; Instrument manual with specification details (Hard copy) to be provided; Shall provide test certificate of the instrument with traceability from the manufacturer; Values obtained for 0.02NTU , 20NTU , 100 NTU and 800 NTU standards shall be included in the test report .IQ/OQ/PQ documentation shall be provided. CE certification shall be provided ; CRM for calibration during PQ shall be supplied by KWA; Warranty : 3years for the entire equipment 3.Jar test apparatus -(minimum 5 jars) Continuous duty geared motor drive with built in speed control, S.S. stirring shafts with adjustable height 4.Electronic Balance (2 weigh up to 1 mg)- Electronic balance accuracy 0.001 gm (1mg) capacity 220 gm -1 No 5. Residual Chlorine test kits (Range from 0.1 ppm to 5 ppm) - 2 Nos 6.Autoclave - Vertical -portable-single wall electrically operated constructed with SS 304 grade capacity 1.5 KW , 20 ltrs -1 No 7.Conductivity Meter - Digital conductivity meter with cell model of approved brand -1 No 8. Colori meter - Digital photoelectric colori meter with 8 filters (1 ml) -1 No. 9. Incubator- Double wall chambers inner made of Aluminium and outer of mild steel sheet duly powder coated with 2 1/2" thick glass wool insulation. Temperature is controlled by an imported thermostat to a maximum of 110 degree celsius with an accuracy of +/-1 degree celsius and working temperature of ambient +5 degree celsius to 80 degree celsius and without thermometer . Size 300 x 300 x 300mm ,250 W, 28 Ltrs -1 No 10. Bacteriological water test kit (Microbiological test) -1 No 11. Laboratory Refrigerator vertical type minimum gross volume 200 ltrs -1 No 12. Distilled water still ( Wall mounting )- It is electrically operated to obtain pyrogen free distilled water made of complete SS (single wall) , fitted with I.S.I marked heaters to ensure trouble free continuous service.Wall mounting clamp is provided with the unit butn without rubber tube ,supplied with cord and plug to work on 220/230V, 3000 W, 4 ltrs/Hr. 13.Glass wares The following minimum number of glass wares of standard manufacturers and other requirements for testing shall be supplied. Beakers, low form with spout; (5 No. 100 ml; 5 No. 250 ml; 5 No. 600 ml; 4 No. 1000 ml; 2 No. 2000 ml) Burette, schellbach, Class B, with interchangeable PTFE key (2 No. 50 ml) Retort stand base, stainless steel, 210 x 130 x 8 mm; with threaded retort rod, 750 x 12.5 mm. (2 No of each). Retort stand boss and clamp (5 No. of each) Measuring cylinders, polypropylene with spout (5 No. 25 ml., 5 No. 50 ml., 5 No. 100 ml. and 2 No. 1000 ml.); Volumetric flasks BS 1792 Class B type, with polystop (5 No. 100 ml., 5 No. 250 ml., 5 No. 500 ml. and 5 No. 1000 ml.); Erlenmeyer flask, DIN 12387 (5 No 200 ml) Pipettes, straight sided BS 700, Class B, graduated to deliver fast flow (10 No. 1 ml., 10 No. 2 ml., 10 No. 5 ml. and 10 No. 10 ml.); Pipettes, bulb, Class B, BS 1583 (2 No. 10 ml; 2 No. 25 ml.) 2 No. pipette fillers; Nessler tubes (20 pairs 50 ml. and 5 pairs 100 ml.); Racks for Nessler tubes (5 No. 50 ml. and 2 No. 100 ml.); 10 No. Plastic sample bottles with screw caps of capacity 500 ml; 10 No. Plastic sample bottles with screw caps of capacity 1000 ml; 4 No. Plastic buckets of capacity 10 litres; Beakers, Pyrex, low form with spout (10 No. capacity 100 ml., 5 No. capacity 250 ml. and 5 No. capacity 1000 ml); 5 No. Wash bottles capacity 600 ml; Filter Papers (Whatmann) 15 cm diameter (10 No. boxes No. 1 Grade and 10 No. boxes No. 42 Grade); 10 No. Funnels, plain glass, conical, 75 mm diameter; Glass rod -6 Nos,Spatula -2 Nos,Porcelain dish -2 No 14.Chemical Reagents Aluminium standard solution; 1000 mg/l 2 x 500 ml Ammonia 35% solution 4 x 1000 ml DPD tablets No 1 (comparator) 2000 No. DPD tablets No.3 (comparator) 2000 No. 25 Hexamine 4 x 500 g Hydrochloric acid 6 x 1000 ml Hydroxylammonium chloride 2 x 500 g Indicator solution, BDH 4.5 2 x 500 ml 1, 10 Phenanthroline hydrochloride 6 x 5 g Pyrocatechol violet 2 x 5 g Sulphuric acid, 0.02 N (0.01 M), CONVOL 3 carton x 6 ampoules All chemicals to be of Analytical Reagent (AR) or equivalent grade

1

-

-

... More
OD190814/2023-2024: Supply of following office furniture and other items for WTP office as per the direction of Engineer in charge 1. Double drawyer table steel 4 ft x 3 ft minimum size -3 Nos 2. Steel armed chairs - 5 Nos 3. Steel Almirah - 185cm x 90cm x 50 cm or nearest size -2 Nos 4.Visitor Chair with steel body - 10 Nos

1

-

-

... More
OD190824/2023-2024:Preparation of detailed design of civil, mechanical , electrical and hydraulic components of WTP including submission of design and drawings for the approval of competent authority of KWA

1

-

-

... More
OD190869/2023-2024: Supply of filled liquid chlorine gas tonner tested and certified by controller of explosives for disinfection of treated water

3

-

-

... More
Road Restoration PWD

-

-

-

... More
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m

514.08

-

-

... More
3.19.1:Loosening of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of table 300-2 for Compacting original ground supporting sub-grade construction.

514.08

-

-

... More
4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method

257.04

-

-

... More
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

257.04

-

-

... More
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

1713.6

-

-

... More
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

1713.6

-

-

... More
5.2.b:Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.

1713.6

-

-

... More
5.3.2.a:Providing and laying bituminous macadam with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading premixed with a bituminous binder (VG 30), transported to the site, laid over a previously prepared surface with paver finisher to the required grade, level, and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction For Grading II - (19 mm nominal size)

85.68

-

-

... More
5.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)

51.41

-

-

... More
access bridge -elastomeric bearing

-

-

-

... More
13.14:Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

640000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.