Kerala Water Authority Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Water Authority - KWA Tender

Works
Civil And Construction
Machinery and Tools
Water Storage And Supply
Eprocure
Opening Date15 Nov 2024
Closing Date27 Nov 2024
Tender Amount₹ 5,19,27,322 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100.7.2:Bailing out water with engine and pump set above 5HP up to 10HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.

5000

-

-

... More
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

115

-

-

... More
100.3.9.1:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.

201.5

-

-

... More
100.3.10.2:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.0m including neat banking.

180.31

-

-

... More
100.3.10.3:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.50m including neat banking.

160.29

-

-

... More
100.3.10.4:Earthwork in open well excavation (above water) for wells of diameter above 9.0m and up to 12.0m in ordinary rock and conveying and depositing the spoil within initial lead of 50m and lift from 4.50m to 6.0m including neat banking.

387.89

-

-

... More
OD78855/2024-2025: Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift up to 7.50 m(lift 6.0m to 7.50 m) but excluding bailing out water and including providing protection by earth filled cement bags(300 Nos. of sand filled cement bags/10 m3 blasting) to avoid damages to the nearby structures.

322.57

-

-

... More
OD78856/2024-2025: Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift up to 7.50 m(lift 7.5m to 9.0 m) but excluding bailing out water and including providing protection by earth filled cement bags(300 Nos. of sand filled cement bags/10 m3 blasting) to avoid damages to the nearby structures.

289.6

-

-

... More
OD78857/2024-2025: Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift upto10.5m(lift 9.0m to 10.5m) but excluding bailing out water and including providing protection by earth filled cement bags(300 Nos. of sand filled cement bags/10 m3 blasting) to avoid damages to the nearby structures.

198.98

-

-

... More
OD78858/2024-2025: Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift upto10.5m(lift 10.5m to 12m) but excluding bailing out water and including providing protection by earth filled cement bags(300 Nos. of sand filled cement bags/10 m3 blasting) to avoid damages to the nearby structures.

169.56

-

-

... More
OD78859/2024-2025: Granite rock blasting in wells,measured in solids,including collecting and stacking spoil for measurement within the intial lead of 50m and lift upto10.5m(lift 12m to 13.5m) but excluding bailing out water and including providing protection by earth filled cement bags(300 Nos. of sand filled cement bags/10 m3 blasting) to avoid damages to the nearby structures.

169.56

-

-

... More
OD78860/2024-2025:Providing dowel bars by drilling holes for dowel rods for anchoring foundation of GL tank using 16mm dia bars at 60cm c/c, holes of size 19 mm to 22mm dia 60 cm deep including cost of all necessary materials, labour charges etc. complete as per the direction of departmental officers.

180

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

33.06

-

-

... More
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

92.26

-

-

... More
OD78861/2024-2025: Centering and shuttering including strutting,propping etc and removal of form for weather shade, chajjas, corbels etc including edges( circular form work, height above 3.5 m- additional 1m height)

176.05

-

-

... More
OD78862/2024-2025:Centering and shuttering including strutting, propping etc. and removal of form for Suspended<br>floors, roofs, landings, balconies and access platform (For floors slab of OH tank at 6 m height and for roof slab at<br>10 m height) (Based on 5.9.3)

12.92

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

45.72

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

262.47

-

-

... More
OD78863/2024-2025: Centering and shuttering including strutting, etc. and removal of form for:<br>Suspended floors, roofs, landings, balconies and access platform - additional 20 % rate for Circular form work

114.99

-

-

... More
50.5.7:Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

176.34

-

-

... More
OD78864/2024-2025:Centering and shuttering including strutting, etc. and removal of form for:<br>Lintels, beams, plinth beams, girders bressumers and cantilevers - Additional rate for circular form work 20%

881.71

-

-

... More
50.5.33.1:Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work up to plinth level

54.87

-

-

... More
OD78865/2024-2025:Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (For floors slab of OH tank at 11.70m height and for roof slab at 16.50m height) (Based on 5.9.3)

32.5

-

-

... More
50.5.33.2:Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level

43.25

-

-

... More
OD78866/2024-2025: Centering and shuttering including strutting,propping etc and removal of form for weather shade, chajjas, corbels etc including edges( circular form work, height above 3.5 m- additional 1m height)

121.2

-

-

... More
OD78867/2024-2025: Centering and shuttering including strutting,propping etc and removal of form for weather shade, chajjas, corbels etc including edges( circular form work, height above 3.5 m- additional 1m height)

117.86

-

-

... More
OD78868/2024-2025: Centering and shuttering including strutting,propping etc and removal of form for weather shade, chajjas, corbels etc including edges( circular form work, height above 3.5 m- additional 1m height)

40.76

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

42044.04

-

-

... More
6.4.1:Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)

45.76

-

-

... More
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

776.86

-

-

... More
OD78869/2024-2025:Extra for plastering on circular work not exceeding 6 m radius

776.86

-

-

... More
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

730

-

-

... More
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

5

-

-

... More
10.7:Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.11.1:Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side/top/centre hung, with beading and all members such as F7D, F4B, K11B and K 12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)

267.16

-

-

... More
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

878.6

-

-

... More
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

170.64

-

-

... More
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

198.24

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

199

-

-

... More
100.41.33:Supplying and fixing 500mm dia C.I. manhole cover with frame (medium duty) charges including all cost, labour charges etc., complete.

2

-

-

... More
13.71:Lettering with black Japan pint of approved brand and manufacture

100

-

-

... More
18.73.10:Providing and laying Double Flanged ( Screwed / Welded ) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS: 8329 :600 mm dia Ductile Iron Double Flanged

24

-

-

... More
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.

3

-

-

... More
100.31.1.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class I.

3

-

-

... More
OD78870/2024-2025:Supply of 500 mm CI Wall casting pipe

3

-

-

... More
OD78871/2024-2025:Supply and installation of 600 mm Dia CI bell mouth strainer

3

-

-

... More
Construction of Retaining wall around well at Kalakkadavu

-

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

96.6

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

13.8

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

11.96

-

-

... More
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.96

-

-

... More
50.5.33.1:Providing and laying in position machine batched and machine mixed design mix M- 20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work up to plinth level

19.15

-

-

... More
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

69.01

-

-

... More
50.5.33.2:Providing and laying in position machine batched and machine mixed design mix M-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level

2.31

-

-

... More
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

24.47

-

-

... More
OD78872/2024-2025:rubble masonry with hard stone in foundation and plinth , up to plinth level .etc complete.

195.94

-

-

... More
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

285

-

-

... More
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

524.4

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

24

-

-

... More
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

13.87

-

-

... More
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

13.87

-

-

... More
Supply and Installation of Raw Water Pump sets

-

-

-

... More
OD78873/2024-2025:Design, Supply, erection, testing and commissioning of (KWA/Department approved) V T pump set- 2 Nos (1 No as standby) having Discharge 196.76 LPS and head 72m and having overall efficiency of 70% and all allied works .Work include PUMP-Supply, erection and commissioning of KWA pre-qualified reputed make Centrifugal type vertical turbine pump sets with Bronze/SS impellers, shaft and CI pump casing etc . The pump set shall be suitable to couple with vertical hollow shaft motor. The duty condition of pump set are discharge 196.76 LPS, Total head 72m delivery size so as to suit the existing pumping main.. MOTOR:-Supply erection testing and commissioning of KWA pre-qualified reputed make F.L.speed of motor 1450 rpm, supply of screen protected drip proof squirrel cage vertical hollow shaft induction motor suitable for operation on 3.3 Kilo volts 3 phase 50Hz.AC supply for the above pump set. The motor should confirm to IS 325..Supply of the motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation including cost of cement ,sand and metal etc .complete .Flexible coupling shall be used for coupling of pumps and motors. Motor shall be provided with all sensors for operating motor protection relay as per IS standards. STARTER:-Supply ,erection testing and commissioning of suitable rating 3.3 KV ,3Phase 270 HP heavy duty FCMA Soft starter with all protections and incorporated with motor protection relay ,digital type multifunction meters , indicators and shall be provided with a bypass contactor of suitable rating ,earthing ,busbar interconnections, control wiring complete as per standards and supplying of suitable size cables with all terminations required of best quality ISI make for panel board from insulator to starter, starter to motor ,capacitors etc, including necessary cabling through suitable PVC conduit and cable trays ,termination cables ,gland etc .confirming to Safety regulations. 3.3KV Isolator Panel : - -Supply, erection testing and commissioning of 3.3KV TP Vacuum isolators for the 2 Nos 3.3.KV motor Soft starter consisting of suitable capacity 3.3KV TP isolators in sheet steel enclosure with mechanical interlocks facility and voltmeter selector switch, ammeter with selector switch, fitted with 3nos .of indicator lamps with all bus bar inter links, fittings etc as per IE rules. Interlocks shall be arranged in such a way that only one of the pumps can be operated at a time. These isolators can also be integrated with the Soft Starter Panel by fixing the same inside the soft starter panels. The panel shall be fitted on a common base frame on suitable foundation. CABLING WORK: -Supply, laying, testing and commissioning of suitable size 3.3KV XLPE cables for the above pump set from 3.3 KV isolator to Soft starter panel and then to the motor considering energy conservation. EARTHING:- Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/Copper strip buried in ground and giving double earthing to motor, starter ,panel board etc.as per IE standards with suitable cable and connecting the same to the earth pit provided as per IS 3043/87 and IE rules and code of practice etc. complete.. CAPACITOR:-Supply erection testing and commissioning of heavy duty 3.3KV APP capacitor for the motor to get a power factor above 0.95 the capacitor shall confirm to IS 2834 VALVES:-Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and non-return valve with suitable pressure rating .Fitting of valves shall include proper RCC support especially for non return valves .in case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. SUCTION AND DELIVERY PIPE CONNECTION:-Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m .suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges ,nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe suitable as per site condition & specials shall be provided. Fabricating and connecting delivery pipe of required size with Y-connection and necessary joints made out of suitable size MS pipe in suitable length with required flanged joints and seating on supports as per site condition. Warranty 2 Year (1 year warranty+ 1 Year additional warranty)

2

-

-

... More
Design, Manufacturing , Supply and Erection of 630KVA indoor transformer and alied works at Raw Water Pump House

-

-

-

... More
OD78811/2024-2025:11KV DOUBLE POLE STRUCTURE : Supply ,assembling and erection of all materials and providing 11KV double pole structure using 2Nos. 175x85mm ISMB/ISMC GI coated joist of 9.5m height, 100x50mm, GI channel cross arms, 3 sets of 400A, 11KV gang operated 3 insulator type AB switches with operating handles of required length, 1 sets of 9.6 KV, 9 KA Lightning arrestors, pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets and including all associated civil works like foundation works for erecting the joist poles, muffing the poles and painting of parts with 2 coats of epoxy primer and epoxy paint of recommended shade wherever necessary and providing 4 Nos pipe earthing using 40mm GI pipe as per IS standard and interconnecting the pits and equipments using 6swg copper conductor etc. complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards

1

-

-

... More
OD78812/2024-2025:Supply, erection, testing and commissioning of 11KV three Panel assembly consisting of 1No 11KV, 630A, 350MVA, 26.3KA,3sec totally enclosed VCB as incomer, 1No 11KV, 630A, 350MVA, 26.3KA,3sec totally enclosed VCB panel and one number 11KV LBS as out goings and shall be single bus bar, floor mounting in metal clad, indoor extensible type flush mounted , suitable for installation in 3 phase , 3wire, 50Hz. AC,11KV, effectively earthed supply system, comprising of motorised and spring assisted, protective relays etc. draw out type with metering as well as protections CTs and PTs for panel metering. The VCBs shall be of horizontal isolation type and draw out type fitted with manual/motor operated spring charge mechanism with 230V AC motor and motor control switch, shunt trip coil of 24 volt DC auxiliary contact 6NO+6NC, Mechanical ON/OFF indicator, Mechanical operation counter, Anti pumping feature, Automatic safety shutters and push button etc . The LBS shall be 11kv,630A, 26.3 kA/1 sec rating and shall consist of mechanical / electrical Trip bush button ,ON/OF Indicator ,Space heater with thermostat , 230VAC shunt trip coil 3nos HT HRC Fuses etc., .1 no. outgoing VCB is for 630KVA ,11KV/3.3KV transformer and the LBS is for 63KVA transformer and shall consist of protective relays for the protection of respective transformers as per CEA regulations and guide lines issued by the Electrical Inspectorate and shall be fitted with a sealable KSEB metering panel with resin cast PT 11KV/110V ,150VA Class 0.2S-1No and ** /5A(ratio as per contract demand) , Class 0.2S ,15VA current transformer-3Nos for KSEB metering and provision for fixing TOD Meter with sealing arrangement and with controlling fuses , LED panel lamps , panel heaters etc complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal inter connections. The cost of control cables both internal and external shall be included in the cost of HT panel, 11KV Switchgear (Indoor)

1

-

-

... More
OD78813/2024-2025:HT TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete.

1

-

-

... More
OD78814/2024-2025:Supply ,Erection , testing and commissioning of Transformers and Allied works, Supply, Erection, testing and Commissioning of Transformer 630 KVA 11KV/3.3KV Indoor Type ,Resin Cast ,ANAN copper wound transformer (KEL/TELK/BHEL /any reputed make) with off load tap changer (+)5% to (-)10% in steps of 2.5% with standard fittings conforming to IS 1180(EEL2). HT side and LT side cable box suitable for XLPE cable termination and with energy efficiency level I, . as per IS specification. Guarantee period 12 months from date of commissioning

1

-

-

... More
OD78815/2024-2025:Neutral Grounding Resistor, Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make neutral grounding resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 3mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The resistance shall be of Kerala Electrical Inspectorate and relevant standards. Armoured 2.5 Sqmm copper control cable shall be used for all external interconnections. The cost of control cables both internal and external shall be included in the cost of NGR

1

-

-

... More
OD78816/2024-2025:Supply, erection, testing and commissioning of 3.3KV, 400 A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type panel board comprising of 1Nos. Vacuum Circuit Breaker as incomer, 3nos. Vacuum Circuit breakers as outgoing The incomer switchgears, & outgoing switch gears should be of draw out type trip free VCBs with suitable overload, Earth fault and short circuit protection releases and Standby Earth fault relay through the neutral CT provided, suitable UV and shunt releases for probable integration to control wiring including PLC unit and its auxiliary systems for remote monitoring and operation and provision for future up gradation to SCADA, suitable for installation in 3 phase , 3wire, 50Hz. AC, 3.3kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, MC 61A high set numerical protective relays, . resin cast, 3.3 KV /110/230V PT with control fuse for each incomers 0.2 class dual core CT LED panel indicates digital multi-function meters, with minimum features to read V, A, Hz, PF, THD % in all the outgoing feeders and incomers including suitable CT/PT and protection arrangements, panel, heaters with timer/RTD based automatic operation, suitable SMF battery and battery charger arrangements etc.. Complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of 3.3KV panel, 3.3KV Switch gear.

1

-

-

... More
OD78817/2024-2025:Supply, erection, testing and commissioning of , 63 KVA, 11KV/440V. 3phase, 50Hz,Dyn 11,. Resin cast , Indoor type copper wound distribution transformers, with HV and LV side cable end box arrangements complete with all fittings as per IS 1180 L2 and Kerala Electrical Inspectorate norms and conforming to IS1180 ( Part 1 ). Armoured multi core 2.5 Sqmm copper control cables shall be used for all external &amp;amp; internal interconnections . The cost of control cables both internal and external shall be included in the cost of Transformer.

1

-

-

... More
OD78818/2024-2025:Supply and installation of MSB for 63KVA ,11KV/433V Transformer with incomer-1no 125A,4Pole, 26kA microprocessor based MCCB with 3 O/C and E/F release and stand by earth fault relay as and outgoing 63A ,26kA 4p MCCB -4nos, EFR, indications, Digital Multi-Function Meter with RS485 1 nos, voltmeter, 1 nos ammeter with suitable current transformer, suitable busbar and control wiring etc

1

-

-

... More
OD78819/2024-2025:HT Power Cables - Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqmm

100

-

-

... More
OD78820/2024-2025:HT Cable Terminations - Supplying and making outdoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 300 Sqmm

1

-

-

... More
OD78821/2024-2025:HT Cable Terminations - Supplying and making indoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 300 Sqmm

1

-

-

... More
OD78822/2024-2025:HT Cable Terminations - Supplying and making indoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 150 Sqmm

2

-

-

... More
OD78823/2024-2025:HT Power Cables - Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 150 Sqm

60

-

-

... More
OD78824/2024-2025: HT Power Cables - Supply & laying 3.3KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3.5C x 240 Sqmm

50

-

-

... More
OD78825/2024-2025:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards.3.5 core 240 Sq.mm.3.3kv,XLPE AL Cable(Indoor)

2

-

-

... More
OD78826/2024-2025:HT Power Cables - Supply & laying 3.3KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 150 Sqmm

60

-

-

... More
OD78827/2024-2025:Supply of all materials and providing end termination of the following size/suitable size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. 3 core 150 Sq.mm.3.3KV,XLPE AL Cable(Indoor)

4

-

-

... More
OD78828/2024-2025:ON-OFF Push button station with Emergency Off button in suitable weather proof enclosure and fixing near the motor including supply laying and termination of control cable.

2

-

-

... More
OD78829/2024-2025:Supply,Fabrication and fixing of cable trays and MS angle/supports for cable trays for clamping of cables in trenches/through walls and trusses etc. Angles and plates should be painted one coat of primer and two coat of enamel paint as required as per KEI standards.

1

-

-

... More
OD78830/2024-2025:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

8

-

-

... More
OD78831/2024-2025:Supply and providing pipe earthing as per IS 3043 by using Earthing G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

5

-

-

... More
OD78832/2024-2025:Charges for preparation of electrical scheme and getting energisation approval (including clearing defects if any) from electrical inspectorate.Statutory fee excluded from the cost (statutory fee shall be done by KWA)

2

-

-

... More
OD78833/2024-2025:Supplying and laying of 25x5 mm size copper earthing conducters along with cable/duct bellow ground

100

-

-

... More
OD78834/2024-2025:Supplying and laying of 6 SWG copper wire conductor along with cable/duct bellow ground including

50

-

-

... More
OD78835/2024-2025:Transportation ,erection testing and commissioning of 3.3 KV panels,11KV Panels MSB and SSB

1

-

-

... More
OD78836/2024-2025:Supplying and fixing cable route marker with 10cmx10cmx5mm thick G.I.plate with inscription there on,bolted /welded to 35mmx35mmx6mm angle iron,60cm long and fixing the same in ground as required

6

-

-

... More
OD78837/2024-2025:Supply and providing following safety items. 6 mm thick rubber mat 0.90 m wide 1.80 m long ISI marked- 3 nos, DCP type fire extinguisher 5 kg (ISI marked) - 2 nos, CO 2 type fire extinguisher 5 kg (ISI marked)- 2 nos, fire bucket with floor mounting self stand - 2 nos, shock treatment chart duly framed with glass cover - 2 nos, 11 KV gloves - 2 pair, danger baord - 6 nos, first aid box with medicine - 1 box,earth rod of 3. m long 1no etc.

1

-

-

... More
OD78838/2024-2025:Supplying and laying of 25x3 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required

50

-

-

... More
OD78839/2024-2025:Supplying and laying of 8 SWG copper wire conductor along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required

50

-

-

... More
OD78840/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point ( rate as per SI 120a1)

25

-

-

... More
OD78841/2024-2025:Supplying and fixing yard lighting with GI pole and LED light 35 W

10

-

-

... More
OD78842/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control celing fan with electronic regulator ( rate as per SI 120a7)

3

-

-

... More
OD78843/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point with 6 A 5 pin plug ( rate as per SI 120a3)

5

-

-

... More
OD78844/2024-2025:Supplying and laying one number PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade folloewing size in masonry open duct as required (S&L of 3x2.5 sqmm copper armored cable)

15

-

-

... More
OD78845/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C X 2.5 sq. mm

6

-

-

... More
OD78846/2024-2025:Supplying and laying of following size of 1.1 KV grade PVC insulated armored heavy duty aluminium cable as per I S through built-in trenches/ cable trays including clamping 3.5 x 95 sq mm

150

-

-

... More
OD78847/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 95Sqmm

4

-

-

... More
OD78848/2024-2025:Supply,conveyance,installation,testing and commissioning of 1200 mm sweep-5 star rated ceiling fan using standard accessories excluding resistant type regular ,wiring the down rod with 16/0 .2mm PVC insulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extended with original wiring as requied

3

-

-

... More
OD78849/2024-2025:(cabling )supply laying testing and commissioning of the following size.PVC XLPE insulated shelthed armoured aluminium conductor cable 1100 /11000 volts grade clamped on wall / cieling with Clamps and saddle clips partly laid in cable tray partly laid in trench for 3.5Cx 25 sq mm PVC XLPE aluminium cable

20

-

-

... More
OD78850/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 25Sqmm

4

-

-

... More
OD78851/2024-2025:supply and wiring light points with 6A plate ceiling of according to various 732- 1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 3419 -1988 fixing the conduit using methyl saddles spacing not exceeding 50cm concealed suitably and with 1 sq mm FR PVC insulated standed single core copper conductor cable 650 B grade including providing switch board main and continuous earthing earth socket brass Bolt and nuts crimpling soldering etc compete with suitable size modular type of metal switch boxes modular type of front plates (white) etc up to and including 6A modular type SP switches and making good the surface of wall colour washing etc complete all the terminations in switich boards and the DB"s shall be tinned and wires shall be drawn and fixied along the Periphery of the box using suitable Ties tie mounts etc. as require

5

-

-

... More
OD78852/2024-2025:Supply, conveyance and installation testing and commissioning the light fittings of 1200 mm 1-20 w LED lamp with box type fluxure made from CRCA sheet 0.5 mm thickness with all accesseries and lamps directly on wall and giving connections with 16/0.2 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.

30

-

-

... More
OD78853/2024-2025:Lighting Distribution board (LDB), Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA ELCB, 18 nos 6 AMPS SP MCB as outgoings, &lt;br&gt; With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system

1

-

-

... More
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

17.6

-

-

... More
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

2.2

-

-

... More
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

9

-

-

... More
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

50

-

-

... More
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

450

-

-

... More
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.