Kerala University Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala University Tender

Works
Software and IT Solutions
Eprocure
Opening Date5 Dec 2018
Closing Date4 Jan 2019
Tender Amount₹ 16,62,418 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 mm thick

0.4

-

-

... More
Supply and fixing the following types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue

-

-

-

... More
U' section rubber beeding suitable for 1.60/ 2.00 mm sheet

30

-

-

... More
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.

4

-

-

... More
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade copper strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.

3000

-

-

... More
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required

300

-

-

... More
200 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC

1

-

-

... More
63A,16/25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

6

-

-

... More
rotary kit up to 250 A

7

-

-

... More
Three phase multifunction meters to read V, A and F, accuracy class 0.5

1

-

-

... More
200/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5

3

-

-

... More
20 A Kit kat fuse unit with 2 A HEC fusse link

3

-

-

... More
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.

-

-

-

... More
20 mm dia light gauge

2135

-

-

... More
25 mm dia light gauge

400

-

-

... More
32 mm dia light gauge

30

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

-

-

-

... More
DP enclosure for independent mounting of MCB

5

-

-

... More
FP enclosure for independent mounting of MCB/ RCCB/ RCBO

14

-

-

... More
12 way single phase double cover (IP 42/43)

5

-

-

... More
4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

8

-

-

... More
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required

-

-

-

... More
40 A double pole mini break isolator

5

-

-

... More
63 A four pole mini break isolator

28

-

-

... More
40 A four pole mini break isolator

12

-

-

... More
40 A, 2 pole, 30 mA RCCB

5

-

-

... More
40 A, 4 pole, 100 mA RCCB

4

-

-

... More
63 A, 4 pole, 100 mA RCCB

8

-

-

... More
S & F 6 to 32 A SP MCB

250

-

-

... More
40 A, 10 kA, TP MCB (C curve)

6

-

-

... More
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.

-

-

-

... More
2.50 sq mm 2 run + 1 run 1.5 Sqmm

2360

-

-

... More
4.00 sq mm 2 run + 1 run 2.5 Sqmm

800

-

-

... More
6.00 sq mm 2 run + 1 run 4 Sqmm

200

-

-

... More
16.00 sq mm 4 run

40

-

-

... More
10.00 sq mm 4 run

30

-

-

... More
6.00 sq mm 2 run

140

-

-

... More
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (Group B/ RoHS compliant )

-

-

-

... More
2 module moulded plastic box on surface

4

-

-

... More
3 module moulded plastic box on surface

65

-

-

... More
9 module moulded plastic box on surface

200

-

-

... More
2 module white/ off-white

4

-

-

... More
3 module white/ off-white

65

-

-

... More
9 module white/ off-white

200

-

-

... More
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B RoHS compliant )

-

-

-

... More
6 A SP 1 way switch

600

-

-

... More
16 A SP 1 way switch

65

-

-

... More
6A 3 pin shuttered socket

600

-

-

... More
6/16 A socket

65

-

-

... More
32 A DP switch with indicator

2

-

-

... More
32 A Socket

2

-

-

... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

-

-

-

... More
4 core 120 sq mm

100

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

-

-

-

... More
4 core 10 sq mm with factory made clamp

200

-

-

... More
4 core 16 sq mm with factory made clamp

200

-

-

... More
4 core 25 sq mm with factory made clamp

200

-

-

... More
4c 120 sqmm with fabricated clamps

70

-

-

... More
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation

-

-

-

... More
77 / 63 mm or nearest size

100

-

-

... More
Supply and clamping the following sizes of PVC pipe on wall with all required accessories including cutting and making good the walls, colour washing etc. as required as protective covering to cables.

-

-

-

... More
63 mm dia PVC pipe (8 Kgf / cm2)

20

-

-

... More
Supply route marker with 102mmx102mm cast iron, spike 5mm thick with inscription 'LT Cable' there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.

3

-

-

... More
Supplying siemens / tropodur type nickel plated Double compression brass cable gland with copper earth clamp and crimping type aluminium cable sockets for PVC insulated and PVC sheathed armoured aluminium cable 1.1 KV grade, and making end termination suitable for 4 core cable of the following sizes as required.

-

-

-

... More
10 sq mm

12

-

-

... More
16 sq mm

12

-

-

... More
25 sq mm

10

-

-

... More
120 sq mm

2

-

-

... More
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)

2

-

-

... More
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required

-

-

-

... More
300 x 300 x 6 mm cast iron gully trap with covering

2

-

-

... More
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.

-

-

-

... More
2 x 25 x 3 mm tinned copper strip

0.6

-

-

... More
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.

-

-

-

... More
25 x 3 mm copper strip tinned at the points of contacts

8

-

-

... More
Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).

-

-

-

... More
25 x 3 mm copper strip tinned at the points of contacts

25

-

-

... More
Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for vertical run).

-

-

-

... More
25 x 3 mm copper strip tinned at the points of contacts

25

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.

-

-

-

... More
3.15 mm copper conductor (10 SWG)

390

-

-

... More
2.65 mm copper conductor (12 SWG)

390

-

-

... More
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.

-

-

-

... More
2.65 mm (12 SWG)

30

-

-

... More
3.15 mm (10 SWG)

30

-

-

... More
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required

-

-

-

... More
25 x 3mm brass bolt & nut

30

-

-

... More
Checking of UPS points at Controller of Examinatioon building

100

-

-

... More
Relocation and reinstallation of UPS and battery bank 10 KVA UPS

1

-

-

... More
Relocation and reinstallation of UPS and battery bank 5 KVA UPS

6

-

-

... More
Supplying , threading , laying and jointing of the following sizes of 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads.

-

-

-

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.