Kerala University Of Health Sciences Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 18,585Document Cost
₹ 1,935Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KUHS_695097_1Tender No
8768/2024/17/Works/KUHSTender Authority
Kerala University Of Health Sciences ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement
concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth
level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
7.9
-
-
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and
setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centering,
shuttering complete:1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm
nominal size)
15.64
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.74
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth
and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level
excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :
3 graded stone aggregate 20 mm nominal size)
0.8
-
-
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,
balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor
five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :
1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
0.34
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size)
1.54
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
131.12
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
1.84
-
-
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders bressumers and cantilevers
10.44
-
-
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
172.21
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
168.21
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied
@ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
143.01
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new work
25.2
-
-
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade
made by block making machine with strong vibratory compaction, of approved size, design & shape, laid
in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the
joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
29.5
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including
cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1018.37
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or
more coats on new work
78.26
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as
approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired
by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm)
with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape wherever required.
41.7
-
-
Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L
hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc
coating not less than 275 gm/m2
6.3
-
-
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden
frames with rawl plugs screws etc
90.8
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium
(minimum thickness
39.18
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0
1.98
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and
shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints
with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
6.72
-
-
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm
having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be
moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate
shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be
covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
5
-
-
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door
shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resinmoulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for
fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout
the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table -
3 of IS : 14856, complete as per direction of Engineer-in-charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements