Kerala Tourism Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KTDC_540378_1Bid Award Id
ViewTender No
KTDC/EW/TEH_KLM_Addtional_workTender Authority
Kerala Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.ktdc.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special conditions of electrical works
BOQ Items
Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm
604
-
-
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade
made by block making machine with strong vibratory compaction, of approved size, design & shape, laid
in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the
joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
480
-
-
Dismantling and removing all sanitary and plumbing fittings of existing toilet such as wash basin, closet,
taps, shower arms, health faucet, angle clock etc.removing carefully stacking in convenient places
pointed out by the engineer in charge for reuse including disposal of all debris outside KTDC premises
and cutting and removing all projected parts of existing pipes and fittings etc.and making all the surfaces
ready for fixing new fittings to wall tile etc.complete.
3
-
-
Dismantling of water and waste water lines of any diameter including all accessories and stacking as per
the direction of Engineer in charge
830
-
-
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres
lead.For thickness of tiles 10 mm to 25 mm
112
-
-
Demolishing brick work manually / by mechanical means including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In
cement mortar
0.92
-
-
Demolishing cement concrete manually / by mechanical means including disposal of material within 50
metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including
equivalent design mix)
3.6
-
-
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50
metres lead:Of area 3 sq. metes and below
8
-
-
Providing and laying Ceramic glazed floor tiles of size 300x450mm (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory,
Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including
pointing the joints with white cement and matching pigment etc., complete.
100
-
-
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic
coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting
and finishing complete as per direction of Engineer-in-charge.brSize of Tile 300x450 mm
100
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new work
210
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium
(minimum thickness of powder coating 50 micron)
70
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50
mm thickness
24
-
-
Supplying and fixing in position back coppered mirror (modi float /saint globain) 6mm thick of appropriate
sizes as per requirement and fixing with 6mm thick multiwood of the required size of the mirror fixed in tje
door shutter with silicon sealent etc . complete .The rate including all material cost ,labour charges ,
conveyance etc complete
2
-
-
Providing and fixing veneer finish (teak wood veneer board 4 mm thick) over both sides of existing
shutters of doors and frames (2.1 x 1.0 m) after scrapping and cleaning existing painted surface and
fixing grooves over doors as per drawings provided using spike nails and synthetic resin adhesive to form
a neat pattern as shown in the drawings including all material cost labour charges, etc. complete and
doing necessary modifications on framework, and polishing the surface with melamine polish as per
manufacturer's specification). The rate including all SS beading all material charge, labour charge,
conveyance etc.complete
5
-
-
Providing and fixing stepped false ceiling at all height including providing and fixing of frame work made
of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm
(both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with
flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash
fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger
fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre,
to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each
having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every
junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30
mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with
25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing
and finishing to a flush finish of tapered and square edges of the board with recommended jointing
compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both
sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also
including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as per drawings, specification and direction of the
Engineer in Charge but excluding the cost of painting with:br12.5 mm thick tapered edge gypsum
moisture resistant board
100
-
-
CLAY JALLI BLOCK OF THICKNESS 20X20X7.5 CM INCLUDING CARRIAGE SUNDRIES BELDAR AS PER ENGINEER INCHARGE.COMPLETE
150
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
210
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
220
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat
and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and
making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
3
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste
of standard pattern, including painting of fittings and brackets, cutting and making good the walls
wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass
pillar taps
3
-
-
Supplying and providing UPVC door of required size and design with cylindrical keyless SS door knob or approved equivalent for bath room,the rate includes all material cost ,labour charges ,all other necessary accessaries etc complete(75 x 210) or nearest.
3
-
-
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 63 mm dia Door Elbow
10
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 63 mm dia Bend
10
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC
solvent cement - 63x63x63 mm dia Tee
10
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
5
-
-
Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling
5
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia bend
5
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
5
-
-
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
5
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
5
-
-
Providing, fixing, Floor trap with Anti-Cockroach Trap including all cost conveyance etc
5
-
-
Supply and fitting Godrej Premium Cylindrical lock (Brass) including all cost conveyance and labour charges etc completed
3
-
-
supplying and fixing exposed part kit concealed stop cock and flush cock with fitting sleeve ,operating lever and adjustable wall flange with seal (FUS-CHR-29083K) with regular body of concealed stop cock suitable for 20 mm pipe line with protection cap (ALD-CHR-089) of jaquar/equivalent approved including cost fixing charge etc complete
5
-
-
Supplying and fixing Health Faucet (Cera) or equivalent of approved make including cost, fixing charges etc complete (Model No : CG 105A) including connection pipe and all its accessories
3
-
-
Supplying and fixing 5" gratings heavy duty of approved make including cost, fixing charge etc complete
5
-
-
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
100
-
-
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water
proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
100
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc
63 mm pipe 4 kgf/ cm2
10
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.110 mm pipe 4 kgf/cm2
10
-
-
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
150
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
5
-
-
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
5
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
300
-
-
Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses,
and including cutting to size and shapes where ever required.
40
-
-
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
520
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should
not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of
brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
520
-
-
Providing and fixing rectangular high density polyethylene water storageloft tank with cover, conformingto ISI : 12701, colour of opaque white or asapproved by Engineer-in-charge. The rate includes making necessary holesfor inlet, outlet & over flow pipes. The base support i/c fittings & fixtures fortank shall be paid separately.
3000
-
-
Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
1
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
4
-
-
Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreVertical
4
-
-
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality;65 mm diameter pipe
2
-
-
Providing and fixing G.I. Union in G.I pipe including cutting and threading the pipe and making long screws etc. complete ( New work):65 mm nominal bore
4
-
-
Electrical works
-
-
-
Supply, conveyance, fabrication and erecting medium class GI poles for street lighting using 40mm dia poles coupled to 32mm poles bent to required shape including painting two coats of synthetic enamel paint over coat of zinc chromite primer etc complete as required at site
15
-
-
Supply and providing IP66 rated 25W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source of good quality and reputed make including positioning the fitting in pole top
15
-
-
Supply of 150mm light duty exhaust fan of good quality and reputed make with self opening louvers working on 240V single phase AC supply.
3
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
5
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light
points
5
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
1
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Medium point
10
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
Plug - Medium Point
5
-
-
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
3
-
-
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required
1
-
-
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
2
-
-
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
2
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
3
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
4
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
3
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
3
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
3
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
50
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
35
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
35
-
-
Supply and Laying 3C x 1.5 Sq.mm copper flexible cable of good quality at site (For feeding power to focus lights)
50
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp
50
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with
factory made clamp
50
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for brfollowing size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV brgrade as required.br3 X 4 sq. mm
30
-
-
Supply and providing outdor weather proof junction box(size 200x150mm)including suitable connector bar/DIN rail bar suiting to control MCB as required etc complete (for yard light UG cable entry & UG cable
termination)
20
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
100
-
-
Supply and fixing 10W LED flood light (Warm) including giving connection to nearest point and fabricating a Mounting arrangement using MS angles
5
-
-
Supply of 6W LED recessed ceiling fitting type Light fitting of good quality and reputed make
10
-
-
Supply of 3W LED recessed ceiling fitting type light fittings of good quality and reputed make
6
-
-
Supply and providing 50W LED IP 65 flood light fitting for use on 240V AC supply including foundation and all accessories required for fixing etc complete of good quality and approved make
7
-
-
Supply of 30W LED Green colour flood light of good quality at site
3
-
-
Supply of 9W outdoor LED garden bollards (Warm White) (Make-Bajaj Model -BLBMC or equivalent) including all accessories for fixing etc complete as required at site
25
-
-
Supply of 5W outdoor LED Garden spike lights (Warm white (Make- Luker, Model-LSSPK5W) including giving connectionetc as required at site
10
-
-
Charges for fixing the Green LED flood light in the banyan tree at site including giving connection to Lights etc complete as required at site
3
-
-
Charges for fixing the Bollards and post top lights in the foundtaion and giving connection etc complerte as required at site
25
-
-
Supply and laying 20mm PVC pipe (Medium) of good quality through the ground including 3R x 1.0 Sq.mm wire for looping
50
-
-
Charges for providing foundation in cement concrete of suitable size (1.5ft x 1 ft x 1 ft) including 32mm pVC pipe for cable entry and exit, foundation bolt and nut for fixing the base plate etc for fixing the post type light fixtures
15
-
-
Charges for providing suitable size foundation (1ft x 6 inchx 6 inch) in cement concrete 1:2:4 for fixing bollard lights including providing 32mm PVC pipe for cable entry and exit.
25
-
-
Charges for ground excavation for laying cable direct in ground and refilling the trench etc as required but excluding sand cushioning and protective covering
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements