Kerala Tourism Development Corporation Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Tourism Development Corporation Limited - KTDC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Feb 2025
Closing Date10 Mar 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

521.64

-

-

... More
15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar

173.97

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

1800

-

-

... More
od230160/2024_2025 : Providing and laying at or near ground level kerb of Bangalore Stone in position to the required line , including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge ( length of finished kerb edging shall be measured for payment )

966.48

-

-

... More
od230163/2024_2025 : Supply & Fixing of Bangalore Stone 60 x 60 cm (Box cut) of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

6816

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

1722

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

905

-

-

... More
Pedestrian Bridge

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

444.45

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

328.78

-

-

... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

33.12

-

-

... More
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

8280

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

116.16

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

200

-

-

... More
5.31 : Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.

29.07

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

50

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.68

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

10.92

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5339

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

44.12

-

-

... More
13.106 : Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.

218.64

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

38.93

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

149.85

-

-

... More
20.3.1 : Boring, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M -25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):300 mm dia piles

360

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

29.07

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

3000

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

2500

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

374.4

-

-

... More
od230245/2024_2025 : Exterior Marine grade Spar Varnishing with varnish of approved brand and manufacture :<br>Two or more coats glue sizing with Exterior Marine grade spar varnish or an under coat of flatting varnish for<br>wooden structures as per manufacturer specification. It allows surface preparation with grinding and<br>cleaned surface from contaminent. It allows colors and finishes with at least one moke-up approved by<br>architect. It includes scaffolding, staging at any height, at all levels with necessary machinaries, tools and kits,<br>precautionary measures during the procedure, uniform finish without pin holes, neat and clean surface<br>without any scratches etc. completed up to the level of satisafction. It allows to protect treated surface with<br>covering materials like plastic bubble sheet to be wrapped up with proper tie

286.4

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

321.6

-

-

... More
60.1.1 : RING BUND Type-I-Putting up ring bund as per approved shape 2.5m bottom width, 1m top width using empty gunny/polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund for an average height 2.00m including labour dismantling the bund after completion of the work etc. complete.

108

-

-

... More
od230473/2024_2025 : Providing and Fixing various second class teak wood members for wood plank, beams, battens any types of supports, etc. comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. (B) WOOD RAILS, BEAMS & COLUMNS

25

-

-

... More
od230474/2024_2025 : Providing and Fixing various second class Teakwood members for wood plank, beams, battens any types of supports, etc... comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. Minimum Plank thickness of 50mm

300

-

-

... More
Extension of interpretation centre

-

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

80.2

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

66.36

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

13.84

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

16.63

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

14.51

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

55.32

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

2.76

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

53.45

-

-

... More
5.31 : Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.

22.76

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

22.76

-

-

... More
6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)

17.22

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

127

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

65.1

-

-

... More
13.3.2 : 20 mm cement plaster of mix:1:6 ( 1 cement : 6 fine sand)

42.9

-

-

... More
13.12 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand )and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand) finished rough with sponge.

42.9

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

65.1

-

-

... More
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

108

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

114.92

-

-

... More
9.6.2 : Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part B), including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, all complete as per directions of Engineer-in-Charge and panelling with panels of:12 mm thick pre- laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade I, Type - II marked :

8.46

-

-

... More
9.73.2 : Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete:125x125x27x5 mm

12

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

3

-

-

... More
22.1.1 : Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-charge and consisting of :i ) Ist layer of 22 mm to 25mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS: 2645 in the recommended proportion over the leveling course ( leveling course to be paid separately). Joints separately) joints sealed and grouted with cement slurry mixed with water proofing compound. II) 2nd layer of 25 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate if 10 mm to 12 mm nominal size spreading @ 8 cudm/ sqm thoroughly embedded in the 2nd layerUsing rough kota stone

23.68

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

13.84

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

4997

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

37.56

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

10000

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

2000

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1000

-

-

... More
9.147D.1 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)

9.18

-

-

... More
Upgradation of existing interpretation centre

-

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

1.59

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

1

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

262.52

-

-

... More
15.41 : Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.

153.96

-

-

... More
6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)

1.74

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

15

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

210.85

-

-

... More
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

400.73

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

153.96

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

128.69

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

89.48

-

-

... More
11.47.2 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm

247.75

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

81.84

-

-

... More
9.147D.3 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).

26.15

-

-

... More
Public space at Entrance and terminal deck)

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

671.1

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

269.33

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

83.32

-

-

... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

2.25

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

283.26

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

106.19

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

42.78

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

30.17

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

52.94

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

9.6

-

-

... More
6.1.1 : Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)

45.8

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

42.78

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5616.5

-

-

... More
13.12 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand )and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand) finished rough with sponge.

236.1

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

151

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

79.12

-

-

... More
13.106 : Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.

633.41

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

411.97

-

-

... More
16.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

53

-

-

... More
od230160/2024_2025 : Providing and laying at or near ground level kerb of Bangalore Stone in position to the required line , including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge ( length of finished kerb edging shall be measured for payment )

642.26

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

9.37

-

-

... More
20.2.1 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).300 mm dia piles

150

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

135.8

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

173.27

-

-

... More
od230163/2024_2025 : Supply & Fixing of Bangalore Stone 60 x 60 cm (Box cut) of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

845.78

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

8000

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

3800

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2350

-

-

... More
od230245/2024_2025 : Exterior Marine grade Spar Varnishing with varnish of approved brand and manufacture :<br>Two or more coats glue sizing with Exterior Marine grade spar varnish or an under coat of flatting varnish for<br>wooden structures as per manufacturer specification. It allows surface preparation with grinding and<br>cleaned surface from contaminent. It allows colors and finishes with at least one moke-up approved by<br>architect. It includes scaffolding, staging at any height, at all levels with necessary machinaries, tools and kits,<br>precautionary measures during the procedure, uniform finish without pin holes, neat and clean surface<br>without any scratches etc. completed up to the level of satisafction. It allows to protect treated surface with<br>covering materials like plastic bubble sheet to be wrapped up with proper tie

401.67

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1.08

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

18.63

-

-

... More
9.6.2 : Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part B), including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, all complete as per directions of Engineer-in-Charge and panelling with panels of:12 mm thick pre- laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade I, Type - II marked :

1.73

-

-

... More
9.73.2 : Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete:125x125x27x5 mm

4

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

1

-

-

... More
9.147D.3 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).

3.15

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

7.05

-

-

... More
od230473/2024_2025 : Providing and Fixing various second class teak wood members for wood plank, beams, battens any types of supports, etc. comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. (B) WOOD RAILS, BEAMS & COLUMNS

15.36

-

-

... More
od230474/2024_2025 : Providing and Fixing various second class Teakwood members for wood plank, beams, battens any types of supports, etc... comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. Minimum Plank thickness of 50mm

260

-

-

... More
Wooden Jetty and Deck

-

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

11.88

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1955.5

-

-

... More
5.31 : Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.

19.77

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

19.77

-

-

... More
13.106 : Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.

220.76

-

-

... More
od230245/2024_2025 : Exterior Marine grade Spar Varnishing with varnish of approved brand and manufacture :<br>Two or more coats glue sizing with Exterior Marine grade spar varnish or an under coat of flatting varnish for<br>wooden structures as per manufacturer specification. It allows surface preparation with grinding and<br>cleaned surface from contaminent. It allows colors and finishes with at least one moke-up approved by<br>architect. It includes scaffolding, staging at any height, at all levels with necessary machinaries, tools and kits,<br>precautionary measures during the procedure, uniform finish without pin holes, neat and clean surface<br>without any scratches etc. completed up to the level of satisafction. It allows to protect treated surface with<br>covering materials like plastic bubble sheet to be wrapped up with proper tie

177.44

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

8000

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

1500

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1000

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

19.77

-

-

... More
20.2.1 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).300 mm dia piles

417

-

-

... More
od230473/2024_2025 : Providing and Fixing various second class teak wood members for wood plank, beams, battens any types of supports, etc. comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. (B) WOOD RAILS, BEAMS & COLUMNS

7.82

-

-

... More
od230474/2024_2025 : Providing and Fixing various second class Teakwood members for wood plank, beams, battens any types of supports, etc... comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. Minimum Plank thickness of 50mm

81.24

-

-

... More
Wooden board walk

-

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

100.8

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

13143.6

-

-

... More
5.31 : Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.

146.04

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

146.04

-

-

... More
13.106 : Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.

1902.6

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

146.04

-

-

... More
od230245/2024_2025 : Exterior Marine grade Spar Varnishing with varnish of approved brand and manufacture :<br>Two or more coats glue sizing with Exterior Marine grade spar varnish or an under coat of flatting varnish for<br>wooden structures as per manufacturer specification. It allows surface preparation with grinding and<br>cleaned surface from contaminent. It allows colors and finishes with at least one moke-up approved by<br>architect. It includes scaffolding, staging at any height, at all levels with necessary machinaries, tools and kits,<br>precautionary measures during the procedure, uniform finish without pin holes, neat and clean surface<br>without any scratches etc. completed up to the level of satisafction. It allows to protect treated surface with<br>covering materials like plastic bubble sheet to be wrapped up with proper tie

2087.65

-

-

... More
od230473/2024_2025 : Providing and Fixing various second class teak wood members for wood plank, beams, battens any types of supports, etc. comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. (B) WOOD RAILS, BEAMS & COLUMNS

70

-

-

... More
od230474/2024_2025 : Providing and Fixing various second class Teakwood members for wood plank, beams, battens any types of supports, etc... comp. in various size and types for boardwalk, deck floor etc. to fix on given structural beam, frame work to take load and fixing with ss-304 cleats, plates, washers, custimized nut & bolts, check nuts, anchor fasteners , screws, pins, exterior grade adhesive like 1KPUR of Fevicol or Eqv. per relavent IS Codes with water tightness of joints to fixing parts with necessary ss-304 trimmed supports between frame and planks ( where ever necessary ) to keep entire deck in true line level and alignment to avoid rattle during usage. Plank shall be fixed in continuous manner along the length with joinery & jointed by z-clips & pins on joints as approved per approved shop drawing. Wood plank shall have Min. width of 150mm and shall be placed 3mm to 4mm thru groove between the planks for dripping out water. To protect wood against wrapping, crackes, etc. it shall be wrapped ( fixed chapda )at specified interval per approved shop drawing with ss-304 patti min. 25mmx1mm patti with nails. All wooden members shall be of pressurised seasoned teak wood treated with anti termite chemical layer as per relavent IS CODES - ( 1141-1993, 6313 & respective others ) Note: i) Wood planks' joint shall not be allowed in between the structural member and shall have in single piece in length and width specified in drawing. ii) It shall be touched up for pin holes, hair cracks with wood saw and weather proof adhesive & smoothen. Minimum Plank thickness of 50mm

910

-

-

... More
20.2.1 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).300 mm dia piles

2000

-

-

... More
Watch tower

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

44.3

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

10.72

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

14.63

-

-

... More
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

10150.19

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

20.09

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

12.11

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

22.32

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

11.92

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

2000

-

-

... More
5.31 : Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.

4.62

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

4.62

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

250

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

34.88

-

-

... More
od230163/2024_2025 : Supply & Fixing of Bangalore Stone 60 x 60 cm (Box cut) of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

97.5

-

-

... More
od230445/2024_2025 : Providing and fixing Deck flooring / coping made from high class Wood Plastic Composite (WPC)Panels<br>made from 55%, Wood 35% High grade polymer (HDPE) and 10% Additives like bonding stabilizer , UV stabilizer<br>etc. and the material should follow ASTM D 570, ASTM D 1894, ASTM D 256, ASTM D 790, ASTM D 1525, ASTM D<br>648, ISO 9352, IS 14887:2000. It should be weatherproof and suitable to be used in outdoor spaces with<br>temperature ranging between -40 ̊C to 60 ̊C. WPC decking section should have bulk density of 1.2 g/cm3.<br>Wood Polymer Composites products must be certified as GREEN PRODUCT by IGBC.WPC decking have<br>thickness 23-25mm and width 145mm. 145x23-25mm. The rates are inclusive of all lead and lift, all floor levels,<br>all heights, all material and accessories, fixing, scaffolding, labour etc. complete in all respects.

300

-

-

... More
od230160/2024_2025 : Providing and laying at or near ground level kerb of Bangalore Stone in position to the required line , including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge ( length of finished kerb edging shall be measured for payment )

56

-

-

... More
20.2.1 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).300 mm dia piles

670

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

25000

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

6000

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

3000

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

750

-

-

... More
Signages, street furniture and entrance gate

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

112.24

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

72.74

-

-

... More
16.78.3 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20

49.6

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

5.54

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

10.78

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

26.57

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

4177.52

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

27.05

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

36

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

24.84

-

-

... More
13.3.2 : 20 mm cement plaster of mix:1:6 ( 1 cement : 6 fine sand)

38.36

-

-

... More
13.12 : 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand )and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand) finished rough with sponge.

24.84

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

24.84

-

-

... More
13.83.2 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

50

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

20

-

-

... More
9.6.2 : Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS: 14616 and TADS 15:2001 (Part B), including ISI marked M.S.pressed butt hinges bright finished of required size with necessery screws, all complete as per directions of Engineer-in-Charge and panelling with panels of:12 mm thick pre- laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade I, Type - II marked :

5

-

-

... More
9.73.1 : Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete:150x125x27x5 mm

4

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

4

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

30

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

36.55

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

49

-

-

... More
7.32.2 : Stone work plain in Copings,Cornices, String courses and plinth courses, upto 75mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.White sand stone

0.18

-

-

... More
7.38.1.1 : Stone tile work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.8 mm thick (mirror polished and machine cut edge)Granite stone of any colour and shade

17.02

-

-

... More
od230470/2024_2025 : Providing and Fixing Second class teak wood furniture work for various decks like benches, sittings, table, chairs, etc... All wood work framing such as sitting stands, foot rest, legs, etc.. shall fabricate fromwooden batterns with any shape and size treated with Anti-Termite and Painted with Spar Varnish respectively under related line item specification under approved make list and manufacturer specifications.Table and benches shall have with clear top, comprising of 50mm thick best quality Second class teak wood, of size 2000mmx700mm ( Clear Plank Size: 2000mmx233mm ) & 2000mmx450mm ( Clear Plank length not less than 2000mm ) respectively fixed on Wooden frame work clear top area of any component. It allows: i) All wooden members shall be of seasoned teak wood treated with anti-termite chemical ii ) wood plank top shall be treated with exterior marine grade Spar varnish of MRF/ASIAN or approved per manufacturer specification. Bottom of wood plank floor shall be treated with 2-coats of Black Japan paint with respective primer and application methodology as directed by EIC iii) All supporting post at any interval shall be interlocked and fixed rigidly with planks/metal cleats, screws, nuts & bolts- check nuts ( 60microne Hot deep Galv./ SS-316 ) and heavy duty virgin nylon buffers rigidly fixed to post etc.. complete in true line level and alignment to avoid rattle during usage and per details approved. All Wooden frame structures shall be treated with exterior marine grade Spar varnish under relevant tender item and mfg. spacs. iv ) Various types of molding, grooves, kholiya etc.. shall be dressed with machine and finished in lucrative manner with proper joinery & jointed by z-clips & pins on joints as approved per shop drawing. v) All necessary fittings, fixtures, nut bolts, washer, plates, customize detail for fixing and fittings, exterior grade glues & adhesive, etc. comp. all SS316 shall be with matt / brush finish as desired by architect to complete the entire product with satisfactory level. vi) it shall be wrapped with fixed chapda at specified interval per approved shop drawing with SS-316 patti having min. size 25mmx1mm with SS nails. vii) It shall be touched up for pin holes, hair cracks with wood saw and adhesive & smoothen. Second class teak wood furniture work : Bench : 1500 mm x 450 mm x 900 mm (Ht))

62

-

-

... More
od230471/2024_2025 : Providing and fixing in Stainless steel Floor Mounted Dustbin with dimensions and design as per Architect selection, in SS 316,<br>Dual bins with 50 liters each having Matt / Mirror Finish including required foundation, anchor bolts and fixing details etc.<br>completed as directed by EIC. Including Minimum 2 mockups for approval complete as per instruction of engineer in charge.

36

-

-

... More
od230757/2024_2025 : Supply ,installing & Making a letters "(KUMARAKOM BIRD SANCTUARY)" made of Aluminium material including<br>transportation cost from the source of fabricating to the specific location at site without breaking of edges &<br>erection in line, level, gradient and plumb with necessary testing, setting in position, labour charges for<br>installation with all the necessary required accessories. and with necessary bolting/riveting/ on wooden<br>board. It also includes Shop drawing, Material approval & 2 mockups for approval as per specifications and<br>direction of the Architectural design.

22

-

-

... More
Rejuvenation of internal canal

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

21000

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

21858.38

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

51002.89

-

-

... More
od230184/2024_2025 : Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or<br>waste material by mechanical transport including loading, transporting, unloading<br>to approved municipal dumping ground for lead upto 10 km for all lifts, complete as<br>per directions of Engineer-in-charge.

4918.14

-

-

... More
Softscape

-

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

397.43

-

-

... More
30.2.3 : Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

300

-

-

... More
30.2.4.1 : Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

300

-

-

... More
30.2.13 : Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).

500

-

-

... More
30.2.20 : Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

500

-

-

... More
od230449/2024_2025 : Supplying and fixing of Kenna Indica1ft height as per the direction of the officer in charge including taking pit,manuring, labour and watering

100

-

-

... More
od230450/2024_2025 : Supplying and fixing of Eugenia liver red hedge plants 3ft height as per the direction of the officer in charge including taking pit,manuring, labour and watering

75

-

-

... More
od230451/2024_2025 : Supplying and fixing of Plumeria Alba 6ft height as per the direction of the officer in charge including taking pit,manuring, labour and watering

150

-

-

... More
od230452/2024_2025 : Supplying and fixing of Terminalia Mantaly 12ft height as per the direction of the officer in charge including taking pit,manuring, labour and watering

5

-

-

... More
od230453/2024_2025 : Supplying and fixing of Bauhinia tree 5ft height as per the direction of the officer in charge including taking pit,manuring, labour and watering

50

-

-

... More
od230454/2024_2025 : Supply and installation of shrubs as<br>specified in the detailed drawing including the cost<br>of all transportation, excavation of pits in suitable<br>sizes, planting, filling with available red soil,<br>manure, sand ,etc. complete but excluding cost of<br>red earth & sand. Bougainvillea Glabra (Ht - 3 ft to 4 ft)

50

-

-

... More
od230455/2024_2025 : Supply and installation of shrubs as<br>specified in the detailed drawing including the cost<br>of all transportation, excavation of pits in suitable<br>sizes, planting, filling with available red soil,<br>manure, sand ,etc. complete but excluding cost of<br>red earth & sand. Calathea lutea, Alocasia Macrorrhizos etc (Ht 4ft to 5 ft)

100

-

-

... More
od230459/2024_2025 : Supply and installation of shrubs as<br>specified in the detailed drawing including the cost<br>of all transportation, excavation of pits in suitable<br>sizes, planting, filling with available red soil,<br>manure, sand ,etc. complete but excluding cost of<br>red earth & sand Eugeenia Yellow, Crinum Asiaticum Green, Crinum Asiaticum Brown, Ficus Retusa (Ficus Panda) (ht - 3ft to 4ft)

50

-

-

... More
od230769/2024_2025 : Supplying and fixing of Pearl grass as per the direction of the officer in charge including taking manuring, labour and watering etc. complete

500

-

-

... More
Digital Kiosks

-

-

-

... More
od230807/2024_2025 : Providing and fixing in Android - based Outdoor Digital information kiosk (2 nos) having panel specification of 55 inch screen size, resolution 1920 x 1080, with touch screen and sensor built-in brightness control. The specification of connectivity for HDMI IN is X1, Power port X1, OSD Language is English & local and external IP67 media Player and android OS / Window OS. The specification of special features having tempered glass having anti-reflective glass with IK10 impact-resistant, optical bonded process, IP67 weather proof design, cooling system of fanless+ filteless and operating temperature is 30 deg. C to 55 deg. C. And power specification are AC 110 to 240V power supply, 50/60Hz rated frequency and Shell of Aluminium alloys, including all required software (Online ticket booking software ,Website with SSL certificate,Content, VR videos, photos, e-brochures etc) and all Hardware necessary accessories.<br>

1

-

-

... More
CCTV WORKS

-

-

-

... More
od230779/2024_2025 : Any other Item Not included above but required to complete the Job:-

1

-

-

... More
od230780/2024_2025 : Supply of Gigabit Optical Fiber Switch (8 SFP Optical + 2 Ethernet) with Module<br>

1

-

-

... More
od230781/2024_2025 : Supply, Installation, Testing and Commissioning of SC-LC SM Patch Cord 3 Mtr with all necessary accessories to comply the installation

6

-

-

... More
od230782/2024_2025 : Supply, Installation, Testing and Commissioning of 06 LC Port Loaded LIU SM DinRail Type with all necessary accessories to comply the installation

4

-

-

... More
od230783/2024_2025 : Supply, Installation,testing and commissioning of 8Port POE Network Switch to provide Power and Data Communication for mentioned Camera. With 1 G SFP Module

6

-

-

... More
od230784/2024_2025 : Supply, Installation, Testing and Commissioning of Wall mounted 6U Rack along with power sockets strips and all other require components & acceessories to mount all the equipments for satisfactory job

4

-

-

... More
od230785/2024_2025 : Supplying and drawing of HDMI cable with all supporting ascessories like connectors etc..

15

-

-

... More
od230786/2024_2025 : Supply, Installation, assembling, connection, testing & commissioning of Fiber Optic Single Mode 6 core armoured outdoor with all necessary<br>accessories to comply the installation.

1800

-

-

... More
od230787/2024_2025 : SITC of Wall mounted network Rack for 15U switch mounting with fixing accessorie set.

1

-

-

... More
od230788/2024_2025 : Supply ,installaiton, testing and commissioning of RJ-45 socket outlet point with suitable Front Plate, CRCA sheet steel box with all necessary accessories & hardware etc. with require all accessories to finish the job

4

-

-

... More
od230789/2024_2025 : Supply, Installation, Testing and Commissioning of 1 mtr. Cat 6 Patch cord

8

-

-

... More
od230790/2024_2025 : Supply and installation of 24 Port Gigabit Poe Network Switch. (1 port sfp with module,1port ethernet uplink.)<br>

1

-

-

... More
od230791/2024_2025 : Supply, Installation, Testing and Commissioning of industrial type 43" LED Display for 24x7 runningg (ON), 1920 X 1080 Resolution, 450 CD/M2 Brightness, Wall Mounting Bracket. Approved Makes- SAMSUNG / SONY / LG

1

-

-

... More
od230792/2024_2025 : Hard Drive Disk: SITC of Enterprise surveilliance HDD 8 TB for 30 days storage at D1 resolultion. Approved Makes- Honeywell / Simplex / Siemens/WD

1

-

-

... More
od230793/2024_2025 : Supply, Installation, Testing & Commissioning of 32-channel network video recorder (NVR), Real-time recording: Up to 32 channels 1080P @ 4Mbps, Operating System LINUX, H.265, H.264 high quality decoding, RAID-0/1/5/6/10 support, motion detection, 3 USB 2.0 ports, USB<br>storage device, 2 RJ- 45 port, 1 RS-232, Hot swap, 2 bay HDDs, Support ONVIF Profile S, HTTP/HTTPS, TCP/IP, RTSP, UDP, NTP, HTTPS, DHCP, IP Search protocols can support

1

-

-

... More
od230794/2024_2025 : Supply of Outdoor 8 Megapixel High Definition IP Bullet Camera of good quality & approved make with 3840 × 2160 30fps resolution,4 mm lens, minimum 30 m IR range, H.264 Compression, Video bit rate 32 Kbps~16Mbps, 2.54cm progressive scan CMOS,PoE (Power over Ethernet), 120db Wide Dynamic range, 3D Digital Noise Reduction,Dual stream, DC12V & PoE (802.3af), IP67 Weather Proof, day/night vision,Auto, scheduled Day/Night Switch,RoHS Compliance etc.<br>

12

-

-

... More
od230795/2024_2025 : Supply, installation, testing and commissioning of 25 mm of medium class PVC conduit along with accessories in surface/recess<br>including cutting the wall and making good the same in case of recessed conduit as required.<br>

1000

-

-

... More
od230796/2024_2025 : Supplying and laying 63 mm dia size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required

1800

-

-

... More
od230797/2024_2025 : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

1200

-

-

... More
MV cables

-

-

-

... More
od229865/2024_2025 : Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size<br><br> 3.5C X35 sqmm Aluminium XLPE armoured cable

10

-

-

... More
od229883/2024_2025 : 3.5C X25 sqmm Aluminium XLPE armoured cable

50

-

-

... More
od229902/2024_2025 : 3C X 2.5 sqmm Cu XLPE Armoured cable

316

-

-

... More
od229903/2024_2025 : 3C X 4 sqmm Cu XLPE Armoured cable

600

-

-

... More
od229904/2024_2025 : 4C X 4 sqmm CU Armoured cable

200

-

-

... More
od229905/2024_2025 : 4C X 2.5Sqmm CU XLPE Armoured cable

25

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

1100

-

-

... More
Cable Termination

-

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

12

-

-

... More
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

2

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

6

-

-

... More
Earthing

-

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

3

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

20

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

20

-

-

-

-

-

... More
od229959/2024_2025 : Supply, installation, testing and commissioning of ONLINE UPS system with SMF battery and 30 minute back up and battery rack complete in all respect 1 set of 3KVA UPS single phase input & single phase output for unbalance (computer & ELV) load.

1

-

-

... More
Light Fixtures

-

-

-

... More
od229963/2024_2025 : Supply, Installation, testing & commissioning of SPIKE LIGHT :<br>System Wattage: 12W, Driver Integral: Constant Current<br>Input Voltage: 230-240Vac, Frequency: 50-60 Hz<br>Operating Voltage: 100-277VAC, Operating Temperature: -15°C~+50°C<br>Light Source: CITIZEN, LED Lumens: 1640 lm<br>CRI (Ra): >80, LED Colour Temperature: 3000K/4000K<br>Power Supply: Integral, Power Factor: >0.98, THD: <10%, Surge Protection: 2.5KV, Efficiency: >84%<br>Colour Temperature: 3000K, Luminous flux: 988 lm, Beam Angle: 15° / 25° / 40°<br>Body: Die-cast Aluminium Alloy, Diffuser: Clear Tempered Glass, Mounting: Spike / Die-cast Aluminium Bracket<br>Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING, IP66, IK04, Life: 60,000 hrs<br>Dimension: 113 x 84 x 117mm<br>The luminaire is BIS & CE certifications.<br>(NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature,Fixture sample is to be done and<br>approved by the architect and Engineer incharge after sampling and mock-up before finalization.)(junction box shall<br>be jelly filled IP-67)

4

-

-

... More
od229964/2024_2025 : Supply, Installation, assembling, connection, testing & commissioning of bollard light fixture equivalent to LB-14 Bollard 11-16W LED , LED source of CCT 3000K/4000K/5700K. Constructed out of Extruded circular extruded aluminium housing (with test certificate) Height: 840mm, dia. 100 mm thickness, SS fasteners & Pre-treated silicone gaskets. Finished with<br>acid treatment & pure polyester powder coating with MARINE COATING. Mounting base made of Die-cast aluminium mounting. Base plate 150 x 150 x 4mm thick with 2 elongated holes 20 x 14 to suit 3 nos M10 bolts at CC 130mm with<br>pure polyester powder coating. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foudation with Hot dip galvanised foundation bolts. The mechanical resistence of the luminaire is IK06 and with ingress protection of IP65. This luminaire contains built-in LED modules. LED<br>modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80), Lifespan of the luminaire > 50,000 hours at 40°C. High efficiency Transmission with specially designed extruded seamless Milky white PC diffuser, lamp fixed position. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >84%,<br>power factor >0.9, THD <10%, Colour Rendering Index: Ra>80 . Input voltage of 230-240Vac at 50-60Hz frequency and have an operating voltage of 100-277Vac with Surge protection 2.5KV and have Asymmetrical light distribution and simple electronic On-Off driver. The luminaire is BIS & CE certifications. (NOTE: Final wattage capacity, light fixture<br>colour, light Colour Coding Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.

11

-

-

... More
od229965/2024_2025 : Supply, Installation, testing & commissioning of STEP LIGHT System Wattage: 12W LED, Driver Integral: Constant Current Input Voltage: 230-240Vac, Frequency: 50-60Hz Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C<br>Light Source: NICHIA/osram/cree LED Lumens: 1000 lm<br>CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K<br>Power Supply: Integral, Power Factor: ≥0.95, THD: <10%, Surge Protection: 2.5KV, Efficiency: >85%<br>Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical<br>Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs<br>Dimension: 240 x 83 x 70mm. <br>IP66, IK04, Life: 60,000 hrs<br>Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING.<br>The luminaire is BIS & CE certifications<br>(NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and mock-up before finalization.

1

-

-

... More
od229966/2024_2025 : Supply, Installation, testing & commissioning of UP & DOWN LIGHT : 12W LED ,IP:IP 65, IK:07, Driver Integral : Constant<br>Current, Input Voltage : 230-240Vac , Frequency : 50-60 Hz , <br>Operating Voltage : 100-277Vac , Operating Temperature : -15°C~+50°C, DIMENSION ; 145 X 100 x 150mm with GU10<br>LED Lamp<br>Body : Extruded & die-cast aluminium , Reflector : Mirror finish pure AL , Diffuser : Clear toughened glass , Mounting :<br>Surface - wall<br>Finish : Graphite Grey <br>Light Source : COB LED , Lumens : 1800 lm , CRI (Ra) : >80 , LED Colour Temperature : 3000K / 4000K <br>Power Supply : Integral , Power Factor : ≥0.95 , THD : 85% Luminous flux : 1219 / 1186 lm for 25° Beam Angle : 15° / 25° /<br>40° <br>(NOTE: Final wattage capacity, light fixture colour, light Colour Coding Temperature, Fixture sample is to be done and approved by the architect and Engineer in charge after sampling and mock-up before finalization.

14

-

-

... More
od229967/2024_2025 : Supply, Installation, testing & commissioning of 20W hanging light point<br>System Wattage: 20W LED, Driver Integral: Constant Current<br>Input Voltage: 230-240Vac, Frequency: 50-60Hz<br>Operating Voltage: 100-277Vac, Operating Temperature: -15°C~+50°C<br>Light Source: NICHIA, LED Lumens: 1800 lm<br>CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K<br>Power Supply: Integral, Power Factor: ≥0.95, THD: <10%, Surge Protection: 2.5KV, Efficiency: >85%<br>Colour Temperature: 3000K,4000K, Luminous flux: 656 lm, Light Distribution: Asymmetrical<br>Body: Die-Cast Aluminium, Diffuser: Clear Polycarbonate, Gasket: EPDM, Mounting: Wall - Surface, IP65, Life: 60,000 hrs<br>Dimension: 220 x 40 x 95mm. <br>IP66, IK04, Life: 60,000 hrs<br>Finish: Graphite Grey/Anthracite Grey/Jet Black with MARINE COATING.<br>The luminaire is BIS & CE certifications (NOTE: Final wattage capacity, light fixture colour, light Colour Coding<br>Temperature,Fixture sample is to be done and approved by the architect and Engineer incharge after sampling and<br>mock-up before finalization.)

10

-

-

... More
Pole and Foundation

-

-

-

... More
od230234/2024_2025 : Construction of Foundation for Bollard of size 300 mm Length , 300 mm width, 450 mm depth including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of M-30 for foundation<br>also having 100mm thick PCC in M-10 and 150mm thick rubble soling at bottom level. It shall be completed with all<br>respect in true line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction. (Foundation should be designed as per wind speed of local area guidelines.

11

-

-

... More
od230235/2024_2025 : Construction of Foundation for ELV Pole of size 300mm Length , 300 mm width, 900mm depth including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of M-25 for foundation also having 100mm thick PCC in M-10 and 150mm thick rubble soling at bottom level. It shall be completed with all respect in true line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction. (Foundation should be designed as per wind speed of local area guidelines.

6

-

-

... More
od230236/2024_2025 : Providing and fixing approved make FRP Type Circular poles. The pole should be made as per IS. with required base plate suitable suspend local wind speed to be erected on existing foundation including all other accessories required.<br>(B) 4 Mtr. Long

11

-

-

... More
Solar System

-

-

-

... More
od230128/2024_2025 : Design, Engineering, Supply, Installation, Testing & Commissioning of 0.5 kWp Off Grid Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earth link, etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc. (Liasoning Work is not included)

1

-

-

... More
Junction Box

-

-

-

... More
od230269/2024_2025 : Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof Outdoor type junction boxes having dimension Height x Width x Depth:- 155 x 210 x 92 mm with terminal having black colour RAL 9011.

12

-

-

... More
od230270/2024_2025 : Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof Outdoor type junction boxes having dimension Height x Width x Depth:- 155 x 210 x 92 mm having black colour RAL 9011.

13

-

-

... More
od230271/2024_2025 : Supply, Transportation, Installation, testing and commissioning of IP-67 Rated weather proof Outdoor type junction boxes having diamension Height x Width x Depth:- 104 x 104 x 70 mm with terminal having black colour RAL 7035.

50

-

-

... More
Distribution Boards

-

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

20

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

3

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

1

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
Internal works - Point wiring

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

10

-

-

... More
1.54.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

3

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

12

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

8

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

35

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

20

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

35

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

-

-

... More
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

3

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

3

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

3

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

3

-

-

... More
1.45 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

3

-

-

... More
od229958/2024_2025 : Supply installation testing and commissioning of 1200 mm sweep BEE 5star rated, Ceiling fan with Brush Less Direct Current (BLDC) Motor class of insulation: B 3Nos blades, 30 Cm long down rod 2 nos of canopies, Shackle kit, safety rope, copper winding Power factor not less than 0.9 service value (CM/M/W) minimum 6 delivery minimum 210 cum/Min.350 Rpm (tolerance as per IS:374/2019) THD less than 10% remote or electronics regulator unit for speed control and all remaing accessories including safety pin, nut bolt washers, temperature rise =75 degree C (max) insulation resistance more than 2 mega ohm, suitable for 230 V,50 Hz, single phase AC supply, earthing etc. complete

3

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

15

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

15

-

-

... More
LT Panel

-

-

-

... More
od230265/2024_2025 : Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle<br>Panel board<br>Assembling and wiring of component supplied separately.<br>Earthing all components, frame etc. to a common internal earth bar.<br>Connection, testing & commissioning.<br>Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the<br>consultant or engineer-in-charge.<br>Supporting rigid steel framework.<br>Cubicle type, 14 gauge CRCA sheet steel enclosed.<br>Proper bonding to earth.<br>Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit<br>diagram.<br>Providing cable clamps / supports within distribution boards cable alley.<br>TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.<br>All MCB’s shall be of minimum 10 KA breaking capacity.<br>The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases<br>upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise.<br>All motor feeders MCCBs shall be of motor duty.<br>Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.<br>Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.<br>IP 54 for all Indoor panel.<br>IP 65 and double door for all outdoor panel.<br>All MCCB’s shall be provided with operating mechanism for door interlock.<br>All measuring instruments (Meters) shall be of digital electronic with LED of approved make.<br>All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.<br>Pad locking of Switch board doors.<br>Pad locking of MCCB’s handles in “OFF” Position.<br>All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive<br>(Motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic.<br>All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.<br>Aproved Makes-L&T/ABB/schnider/Legrand/SIEMENS<br><br><br><br>Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalized, dust tight, vermin proof, water proof 63 A control Panel floor/wall mounting type falling to IP 55 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Bus bars of suitable size, earth bus of adequate capacity, earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry free standing panel consisting of the following as per standards (All switches shall conform to IEC 60898-1 standards) Incoming : 63 A 4P RCCB ,RYB indicators ( LED Pilot type) with 2A Control MCB and toggle switches - 1 Set Multifunction Digital Panel meter with communication port to read V, A, F, pf, kW, kVA, kVAR, kWh, kVAh, kVARh<br>

1

-

-

... More
DWC HUME PIPES AND MANHOLE

-

-

-

... More
14.16.1 : Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)

400

-

-

... More
14.16.3 : 120 mm dia (OD-120 mm & ID-103 mm nominal)

10

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

25

-

-

... More
od230296/2024_2025 : Construction of ELECTRICAL & ELV chamber of size 450x450x600 (1050x1050x850)mm including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes brick work of Walls, R.C.C work of M-30 for top<br>and bottom slabs, also having 100mm thick PCC in M-10 at bottom level. It shall be plastered with 15mm thick Plaster<br>with neat coat in CM 1:3 on internal including water proofing and outside of chamber with 18mm thick cement<br>plaster(underlayer 12 mm thick cement plaster 1 :5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick<br>cement plaster 1:6 ) in two coat at all sides. Top shall be covered with Pre-Cast SFRC Solid MH cover with clear<br>opening of 450x450mm with frame and cover bearing load min. 25t and size as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.