Kerala Tourism Development Corporation Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Tourism Development Corporation Limited - KTDC Tender

Works
Civil And Construction
Eprocure
Opening Date3 Sep 2019
Closing Date3 Oct 2019
Tender Amount₹ 21,50,054 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of Solar And Heat Pump Based Hot Water System At Ktdc-bolgatty Palace Hotel, Kochi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Storage Tank

-

-

-

... More
2000 Ltr calorifier tank made low carbon steel, double Vitreous enameled single coil hot water storage tank with standard utility ports, magnesium sacrificial anode, duly insulated with 100mm rock wool insulation with 20 guage aluminium cladding, top manifold for inspection and cleaning. Temperature guage, air release valve, temperature and pressure release valve, electrical heating port provision alone without heater coils with necessary mounting supports/legs and lifting hooks etc. complete testing to withstand 6kg/cm2 pressure

1

-

-

... More
Solar flat plate collectors of minimum 100 Litre capacity of (Approximate 2mt x 1mt size) BIS certified Copper tube and fins as collector area, low iron 4mm glass cover and aluminium framed structure and necessary supports etc complete as required at site.

20

-

-

... More
Heat Pumps

-

-

-

... More
Air to water heat pump of minimum capacity of 250 litre per hour and having 10kW or nearest output capacity and 2.5 kW or nearest input power requirement working on 3 Phase electrical power at ambient temperature of 20 deg C, CFC free refrigerant, evaporator coil with coating for corrosion prevention, tube in tube copper / SS heat exchanger, expansion valves, expansion vessels, hot gas bypass arrangements, high efficiency fans, with necessary prewired digital control panel with BMS compatibility for automatic operation based on temperature requirement and all the required motor starter circuits, motor overload & short circuit protection components, metering / controls / indication / sensors and related accessories with provision for cable entry size upto 4C x 6 Sqmm Aluminium conductor housed in a powder coated steel housing pre factory tested and certified.

1

-

-

... More
Timer based operating Automatic hot water recirculation pumps ( 1 HP or nearest ) as per manufacturer / OEM specification & standards. (1W + 1S) -Make- Kirloskar or Equivalent

2

-

-

... More
Circulation pump of required capacity to circulate water between solar panels and calorifier tank with differential temperature controller including all other accessories required for the operation such as RTD etc . (1W+1S ) Make- Kirloskar or Equivalent

2

-

-

... More
25mm copper pipeline between solar collectors and calorifier tank and heat pumps with suitable thickness nitrile rubber sleeve insulation and aluminium tape covering etc complete as required at site including adequate supporting for pipe lines

20

-

-

... More
Centralized Control Panel for the operation of heat pumps, circulation and re circulation pumps and all other electrical accessories in the system in a dust tight, vermin proof Enclosure having provision for cable entry / outgoing as per standards with suitably rated MCB/MCCB as incomer and SP/TP MCBs as outgoing, starters, timers, motor over load protection devices, Multi function meter to read current, Voltage and Active power etc. The control connections shall be wired using PVC insulated 1 Sqmm copper conductor etc. complete using good quality and approved make of materials.(Approved make for al components- L&T, Schnider, Siemens).

1

-

-

... More
Part-B For Marina Block

-

-

-

... More
Hot water system based on Heat pump alone

-

-

-

... More
Storage Tank

-

-

-

... More
2000 Ltr calorifier tank made low carbon steel, double Vitreous enameled single coil hot water storage tank with standard utility ports, magnesium sacrificial anode, duly insulated with 100mm rock wool insulation with 20 guage aluminium cladding, top manifold for inspection and cleaning. Temperature guage, air release valve, temperature and pressure release valve, electrical heating port provision alone without heater coils with necessary mounting supports/legs and lifting hooks etc. complete testing to withstand 6kg/cm2 pressure

1

-

-

... More
Heat Pumps

-

-

-

... More
Air to water heat pump of minimum capacity of 250 litre per hour and having 10kW or nearest output capacity and 2.5 kW or nearest input power requirement working on 3 Phase electrical power at ambient temperature of 20 deg C, CFC free refrigerant, evaporator coil with coating for corrosion prevention, tube in tube copper / SS heat exchanger, expansion valves, expansion vessels, hot gas bypass arrangements, high efficiency fans, with necessary prewired digital control panel with BMS compatibility for automatic operation based on temperature requirement and all the required motor starter circuits, motor overload & short circuit protection components, metering / controls / indication / sensors and related accessories with provision for cable entry size upto 4C x 6 Sqmm Aluminium conductor housed in a powder coated steel housing pre factory tested and certified.

2

-

-

... More
Providing and fixing 1" Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (SDR 11)

25

-

-

... More
Timer based operating Automatic recirculation pumps (1 Hp or nearest) as per manufacturer / OEM specification and standards.(1W + 1S) Make- Kirloskar or Equivalent

2

-

-

... More
Centralized Control Panel for the operation of heat pumps and re circulation pumps and all other electrical accessories in the system in a dust tight, vermin proof Enclosure having provision for cable entry / outgoing as per standards with suitably rated MCB/MCCB as incomer and SP/TP MCBs as outgoing, starters, motor over load protection devices, Multi function meter to read current, Voltage and Active power etc. The control connections shall be wired using PVC insulated 1 Sqmm copper conductor etc. complete using good quality and approved make of materials.(Approved make for al components- L&T, Schnider, Siemens).

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.