Kerala Tourism Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 47,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KTDC_676212_1Bid Award Id
ViewTender No
AE(E)I/KTDC.EW-TVM/2065/Aqua Land/DG/2024Tender Authority
Kerala Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.ktdc.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Alternator
-
-
-
100kW Brushless, Self-excited, Self-regulated alternator suitable for continuous operation at 1500rpm with Automatic voltage regulation system to Generate 3 Phase, 4 Wire 415V +/- 1 % AC 50Hz at 0.8 lag pf Supply, insulation class F/H, 2/3 pitch, double layer lap wound stator winding, dynamically balanced rotor, low THD conforming to BS 5514 & ISO 3046 of Stamford / Crompton / BHEL or equivalent make as recommended by the OEM.
-
-
-
Accoustic Enclosure
-
-
-
Canopy type Acoustic enclosure including air intake / exhaust baffles, sliding doors with suitable hinges, locks etc. for the DG sets using acoustically treated panels housed in 1.6 & 3mm / 0.5mm CRCA / LCMS / HRCA sheet steel section filled with special grade 100 mm Thick 96 kg/m3 Density Rock Wool, covered with R. P. Tissue Paper and Expended metal on wall specially designed for optimum sound attenuation with frameworks complete with inspection lamps, inspection glass window, provision for Cable Entry, control cables, etc. complying to IS 8183.
-
-
-
Generator Control Panel
-
-
-
Dust tight, vermin proof GCP falling to IP43 category fabricated out of 16 / 18 SWG CRCA Sheet Steel painted as per standards of the following specifications ( All switches shall confirm to conforming to IEC 60947-2 standards).
-
-
-
The Panel shall be provided with Digital Engine Controller unit suitable for integration to AMF Relay system, suitable rating MCCB/MCB with O/C & S/C Protection as recommended by OEM, TPN best conductivity busbar with SMC supports, heat shrinkable sleeves etc. capable to handle generator full load current.
-
-
-
Suitable rating Class 1.0 Metering CTs per phase as recommended by OEM, multifunction / induvidual meters to read current in each phase, line to line and phase voltages, frequency, energy generated ( Wh) per phase and cummilative, hours of operation, powerfactor status, RYB Phase indicators ( LED Pilot type ) with suitable rating control MCB including all necessary control wiring etc. complete as per standards. ( Note : - The GCP shall meet all the statutory requirements complied with the Kerala State Electrical Inspectorate )
-
-
-
Stantard accessories
-
-
-
Both Engine & Alternator shall be suitably coupled and mounted on common channel iron base frame with standard accessories such as anti vibration pad, required capacity battery, suitable battery-charger unit with charging arrangements from direct mains, As per OEM standards Capacity Diesel tank, residential type silencer, suitable cable termination box etc. complete as per Electrical Inspectorate standards, rules & regulations
-
-
-
The DG Control Panel shall be compatible for PLC based Auto mains failure system employed in the Main Panel.
-
-
-
125 kVA DG SET
1
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
5
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
60
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
4
-
-
Supply and laying 4Cx1.5 sqmm armoured copper control cable along with main cable through trench/wall/ ceiling
60
-
-
Supply and laying 2Cx2.5 sqmm armoured copper control cable along with main cable through trench/wall/ ceiling for the battery charging.
60
-
-
Providing cable glanding for 4C x 1.5 sqmm & 2C x 2.5 sqmm control cable using Siemens type Brass compression gland & Copper lugs etc. complete
4
-
-
Supply, installation, testing and commissioning of outdoor type panel conforming to IP 65 standards with
200 A 4P Automatic Transfer Switch, 2 P selector switch, MCB for battery charger, indication light, ON Delay timer, UV and OV relays and other necessary components for the proper working of the electrical
system.
1
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
3
-
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by
overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
40
-
-
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
20
-
-
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required
3
-
-
Supplying and fixing of MS, B Class exhaust gas pipe of dia. upto 100mm conforming to IS:3589 cut to required lengths along with necessary bends,supports,clamps,anti-vibration mountings etc. as required
upto the top of the nearest building as per pollution control board norms.
6
-
-
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
6
-
-
Generator roofing
-
-
-
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete
160
-
-
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc complete
60
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape wherever required
22
-
-
Providing and fixing of color coated PVC rain water gutter of standard size as per the site requirement
10
-
-
DG operating sanction
-
-
-
Preparation and submission of latest scheme drawings before the Electrical Inspectorate, obtaining approval, arranging inspection and obtaining sanction orders for the newly installed DG set etc. complete
including statutory expenses.
1
-
-
Preparation and submission of latest scheme drawings to KSEB for obtaining sanction for power allocation (Including all incidental and statutory expenses) .
1
-
-
Charges for dismantling and moving the existing 3-phase 62.5 KVA DG set (including change over switch, cables etc.) to a nearby location, demolition of the wall of the existing DG room for the installation
of a new 125 KVA DG set, if necessary, etc. complete as per the direction of the site engineer.