Kerala Tourism Development Corporation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Tourism Development Corporation Limited - KTDC Tender
Electrical and Electronics
Eprocure
Opening Date26 Sep 2024
Closing Date9 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 17,200Document Cost
₹ 1,652Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KTDC_691390_1Bid Award Id
ViewTender No
KTDC/EW/Nilambur/ELE/2024Tender Authority
Kerala Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://https://www.ktdc.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
1
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din
bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
1
-
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 2+12 way, Double door
1
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
36
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
3
-
-
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
2
-
-
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
2
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
40
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
100
-
-
... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm
with factory made clamp
100
-
-
... More
Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium
power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand
cushioning and protective covering (in ordinary soil)3.5 core 120 sq mm
40
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
6
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
4
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.3 1/2X25 sq.mm (28mm)
4
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.3 1/2 X 120 sq. mm (45mm)
4
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
2
-
-
... More
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including
excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)
5
-
-
... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using
clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of
clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal
run)20 x 3 mm copper strip
10
-
-
... More
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).20 x 3
mm copper strip
10
-
-
... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
30
-
-
... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
30
-
-
... More
ITC of DG set
-
-
-
... More
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m
including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50 metres.
3
-
-
... More
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
2
-
-
... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry
enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke
and salt ) as required.
3
-
-
... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required6.00 mm copper conductor (4 SWG)
40
-
-
... More
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.6. mm ( 4 SWG)
20
-
-
... More
Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and
other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium
conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm
2
-
-
... More
Supply & laying of 4C x 1.5 sqmm armoured copper control cable through trench/wall/ ceiling.
20
-
-
... More
Supply and providing 2mm thick, 1mX 2m size electrical grade chequered type rubber mat to withstand
3.3 KV dielectric strength conforming to IS 5429/ 1969.
1
-
-
... More
Supplying and fixing of MS, B Class exhaust gas pipe of dia. upto 100mm conforming to IS:3589 cut to required lengths along with necessary bends,supports,clamps,anti-vibration mountings etc. as required
upto the top of the nearest building as per pollution control board norms.
6
-
-
... More
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5
core 50 sq mm
40
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.3 1/2 X 50 sq. mm (35mm)
2
-
-
... More
Supply & laying following size armoured copper control cable along with main cble through trench/wall/
ceiling.br2cx1.5 sqmm
20
-
-
... More
Providing cable glanding, gland earthing & end termination for 4C x 1.5 sqmm UG Aluminium cable using
Siemens type Brass compression gland & Copper lugs etc. complete
4
-
-
... More
GENERATOR ROOFING
-
-
-
... More
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including
cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete
126.32
-
-
... More
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.
complete
41.16
-
-
... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as
approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired
by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape wherever required.
14.7
-
-
... More
Fees and deposits
-
-
-
... More
Preparation and submission of latest scheme drawings to the Electrical Inspectorate including all MV
additions recently made and obtaining approval, arranging inspection for entire installation, obtaining
sanction orders for the electrical installation, complete (Including all incidental and statutory expenses ).
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements