Kerala State Rural Roads Development Agency Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Rural Roads Development Agency - KSRRDA Tender

Works
Civil And Construction
Construction Material
Eprocure
Opening Date29 Aug 2024
Closing Date27 Sep 2024
Tender Amount₹ 2,91,09,762 
Notes
Download

Costs

Summary

Kr12120 Mrl18-aryanad Anandeswaram Kokottela Vallimangalam Sambhuthangi Pankavu Road

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing and Grubbing Road Land - Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300mm , removal of stumps cut earlier and disposal of unserviceable and stacking servicable material to be used or auctioned, upto a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness as per technical specification Clause 201.1- In Area of non-throny jungle by Mechanical method

11960

34803

2.91

... More
Scarifying Existing Bituminous Surface to a depth of 150mm - by Mechanical Means - Scarifying the existing granular surafce to a depth of 150mm and disposal of scarified material with a lift upto 3m and lead upto 1000m as per technical specification Clause 301.4.1

5966.05

36631

6.14

... More
Dismantling flexible Pavements- Dismantling of flexible Pavements and disposal of dismantled material upto a lead of 100m, stacking serviceable and unserviceable materials seperately by Mechanical means as per technical specification Clause 202.3 - Bituminous Courses

314.17

116211

369.9

... More
Dismantling of Cement Concrete Pavements- Dismantling of Cement Concrete Pavements by Mechanical Means and disposal of dismantled material upto a lead of 1000 m, stacking serviceable and unserviceable materials seperately as per technical specification Clause 202.3

57.75

87325

1512.13

... More
Excavation in soil using Hydraulic Excavator and Tippers with disposal upto 1000m - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location with a lift upto 1.5m and lead upto 1000m as per technical specification Clause 302.3

2475.67

84247

34.03

... More
Construction of embankment with material obtained from Roadway cutting - Construction of embankment with approved material deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300.1 and 300.2 as per technical specification Clause 301.5

2947.05

141929

48.16

... More
Compacting Original Ground Supporting Subgrade- Loosening of the ground upto a level of 300mm below the subgrade level, watered, graded and compacted in leyers to meet requirement given in Table 300.1 and 300.2 for subgrade coonstruction as per technical specification Clause 303.5.2 (Bed cutting portion only)

740.25

43919

59.33

... More
Construction of Subgrade and Earthen Shoulder- Construction of of subgrade and earthen shoulders with approved material obtained from private borrow pits with all leads and lifts transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with lead upto 1000m as per technical specification Clause 303.1

3014.37

1305523

433.1

... More
Supplying, providing and laying woven Coir Geotextile fabric (coir fiber having 2.00 Metre minimum width of H2M5 grade and density .740kg/Sqm) in wrap direction of the embankment with suitable laps o prepared sub grade rolled to 100% of M.D.D as directed by the departmental officers at site.

2400

331800

138.25

... More
Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401 - Using Departmental Material

150.8

32422

215

... More
Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401

980.73

2913072

2970.31

... More
Wet Mix macadam -providing, laying, spreading and compacting stone aggregates of specified sizes to wet mix macadam at OMC in mechanical mixer (pug mill), carriage of mixed material by tipper to site, laying in uniform thickness in sub-base / base course on a well prepared sub-base and compacting with smooth three wheel 80-100 kN static roller to achieve the desired density including lighting, barricading and maintenance of diversion etc as per table 400.11 & 400.12 and as per technical specification Clause 406

2145.22

7114526

3316.46

... More
BITUMINOUS LAYERS

-

-

-

... More
Prime Coat - Low porosity-providing and applying primer coat with bitumen emulsion (Packed SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at a rate of 0.70 - 1.00 kg/sqm using mechanical means as per technical specification clause 502

13531.5

1063575

78.6

... More
Tack Coat - Providing and applying tack coat with bitumen emulsion (Packed RS-1) using emulsion distributor at a rate of 0.25 - 0.30 kg/sqm on the prepared granular surface treated with primer & cleaned with Hydraulic broom as per technical specification clause 503

13531.5

230576

17.04

... More
Mix Seal Surfacing - Mechanical Means - Type A - Providing, laying and rolling of close-graded premix carpet of 25 mm thickness composed of 11.2mm to 0.9mm (Type-A) or 13.2mm to 0.9mm (Type-B) aggregates either using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100kn roller, finished to required level and grades as per technical specification clause 509- Using Bitumen Packed S-65 & using shredded plastic by Mechanical Means

13531.5

3462169

255.86

... More
RIGID PAVEMENT COMPONENTS

-

-

-

... More
Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401

78.98

234580

2970.31

... More
Wet Mix macadam -providing, laying, spreading and compacting stone aggregates of specified sizes to wet mix macadam at OMC in mechanical mixer (pug mill), carriage of mixed material by tipper to site, laying in uniform thickness in sub-base / base course on a well prepared sub-base and compacting with smooth three wheel 80-100 kN static roller to achieve the desired density including lighting, barricading and maintenance of diversion etc as per table 400.11 & 400.12 and as per technical specification Clause 406

39.49

139542

3533.89

... More
Interlocking Concrete Block Pavement- 80mm thick - Laying of interlocking Concrete Block Pavement having thickness 80mm as per drawings as per technical specification clause 1504- without edge block

487.5

444609

912.02

... More
PCC Grade M 20 - Providing concrete for plain/reinforced concrete for wearing coat complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4

21.6

175227

8111.28

... More
C D WORKS

-

-

-

... More
Dismantling of structures- Dismantling existing structures like culverts, bridges, retaining walls and other structures comprising of masonry, cement concrete, woodwork, steelwork, including T&P and scaffolding whereever necessary, sorting the dismantled material, disposal of unserviceable and stacking serviceable material with all lift and lead of 1000m as per technical specification Clause 202.1 - Reinforced Cement Concrete (RCC) - By Mechanical Means

1.62

2106

1298.66

... More
Dismantling Stone Masonry- Dismantling existing structures like culverts, bridges, retaining walls and other structures comprising of masonry, cement concrete, woodwork, steelwork, including T&P and scaffolding whereever necessary, sorting the dismantled material, disposal of unserviceable and stacking serviceable material with all lift and lead of 1000m as per technical specification Clause 202.1 - Rubble Stone Masonry in Cement Mortar

7.68

4567

594.78

... More
Excavation for Structures - Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material : Ordinary soil : Upto 3 m depth

115.82

83177

718.16

... More
PCC Grade M 10 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:3:6

24.81

190325

7671.31

... More
PCC Grade M 15 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2.5:5

88.16

696259

7897.32

... More
RCC Grade M 20 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- upto 5.00m Height

3.16

28027

8869.38

... More
RCC Grade M 25 - Providing and laying reinforced cement concrete in superstructure complete as per drawings and technical specifications Clause 800, 1205.4 and 1205.5 -upto 5.00mtr Height

15.82

160418

10140.86

... More
Supplying, fitting and placing TMT bar reinforcement in substructure - complete as per drawings and technical specifications Clauses 1002, 1005,1010 and 1202

1829.24

156509

85.56

... More
PCC Grade M 20 - Providing concrete for plain/reinforced concrete for wearing coat complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4

4.5

35096

7799.31

... More
Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

80

25531

319.14

... More
RING BUND Type - 1 - Putting up of ring bund as per approved shape 2.50 m bottom width, 1.00 m top width and average height of 2.00 m using empty gunny bag/ Polythene bags filled with earth placed in 2 rows at 0.6m apart and filled in between with puddle clay to form bund including labour charges for dismantling the bund after completion of the work etc complete.

180

479640

2664.67

... More
Providing and Laying RCC pipe NP3 as per design in single row - Providing and laying RCC pipe NP3 culverts on first class bedding of granular material in single row with cement mortar 1:2 but excluding excavation, protectio works, backfilling, concrete and masonry works in head walls and parapets as per technical specification clause 1106 : 1000mm Dia

7.5

48175

6423.39

... More
Granular Sub-base with well graded material (Table 400.1)-By Mix in Place Method- For Grading I material -Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotovator at OMC, and compacting with smooth wheel roller to achieve the desired density as per technical specification Clause 401

22.56

67010

2970.31

... More
Wet Mix macadam -providing, laying, spreading and compacting stone aggregates of specified sizes to wet mix macadam at OMC in mechanical mixer (pug mill), carriage of mixed material by tipper to site, laying in uniform thickness in sub-base / base course on a well prepared sub-base and compacting with smooth three wheel 80-100 kN static roller to achieve the desired density including lighting, barricading and maintenance of diversion etc as per table 400.11 & 400.12 and as per technical specification Clause 406

7.56

26716

3533.89

... More
Cement Concrete Pavement - Construction of un-reinforced dowel jointed at expansion and construction joint only,plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 30 (grade),coarse and fine aggregates conforming to IS383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork spreading the concrete with showels,rakes,compacted using needle, screed, and plate vibrators and finished in continuous operation including provision of contraction and expansion ,construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge /culvert and construction joints, admixtures as approved,curing of concrete slabs for 14 days,using curing compound and water finishing to lines and grade as per drawing and TechnicalSpecifications clause 1501

14.4

132478

9199.91

... More
PROTECTION WORKS

-

-

-

... More
Dismantling Stone Masonry- Dismantling existing structures like culverts, bridges, retaining walls and other structures comprising of masonry, cement concrete, woodwork, steelwork, including T&P and scaffolding whereever necessary, sorting the dismantled material, disposal of unserviceable and stacking serviceable material with all lift and lead of 1000m as per technical specification Clause 202.1 - Rubble Stone Masonry in Cement Mortar

26.4

15702

594.78

... More
Excavation for Structures - Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material : Ordinary soil : Upto 3 m depth

213

152968

718.16

... More
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

720.98

2622380

3637.27

... More
RCC Grade M 20 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- upto 5.00m Height

4.5

39912

8869.38

... More
Guard Stones- Reinforced cement concrete M15 grade guard stones of size 20x20x120cm size embedded in PCC 1:4:8 block of 45x45x45cm sice with 30cm embedding of stones including painting etc. complete.

95

184871

1946.02

... More
SIDE DRAIN

-

-

-

... More
Surface Drains in Soil - Construction of unlined surface drains of average cross sectional area 0.40sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3.0m and lead of 50m as per technical specification Clause 307 - By Mannuall Means

1350

242379

179.54

... More
Excavation for Structures - Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material : Ordinary soil : Upto 3 m depth

459.77

330184

718.16

... More
DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.

91.3

247907

2715.31

... More
PCC Grade M 10 - Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:3:6

64.48

494646

7671.31

... More
PCC Grade M 15 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2.5:5

136.8

1080353

7897.32

... More
PCC Grade M 20 - Providing concrete for plain/reinforced concrete for wearing coat complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- Nominal mix 1:2:4

57.08

445145

7799.31

... More
RCC Grade M 20 - Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203- upto 5.00m Height

10.8

95789

8869.38

... More
Supplying, fitting and placing TMT bar reinforcement in substructure - complete as per drawings and technical specifications Clauses 1002, 1005,1010 and 1202

1080

89629

82.99

... More
ROAD LOGO AND OTHER ROAD FURNITURE

-

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project - Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

17173

17173.79

... More
Providing and Fixing typical PMGSY citizens information board as per MoRD specifications and drawings- Two vertical 76.1mm outer diameter MS sheet tube posts of 3.60mm thickness (medium class) duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x750mm, 600mm below ground level with two horizontal M S Sheet Tubes of 1000mm length to make the frame of board, four horizontals and two verticals with M S Sheet rectamngular Tube 50x25x2mm to make the frame to fix the board as per drawing, two M S Sheet 2.00 mm thick boards of size 900x750mm strengthened by 25mmx5mm MS flat iron including painting with stove enameled paint on both sides as per MoRD specifications. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

23317

23317.97

... More
Providing and Fixing typical PMGSY Maintenance information board as per MoRD specifications and drawings- Two vertical 76.1mm outer diameter MS sheet tube posts of 3.60mm thickness (medium class) duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x750mm, 600mm below ground level with two horizontal M S Sheet Tubes of 1000mm length to make the frame of board, four horizontals and two verticals with M S Sheet rectamngular Tube 50x25x2mm to make the frame to fix the board as per drawing, two M S Sheet 2.00 mm thick board of size 900x1500mm strengthened by 25mmx5mm MS flat iron including painting with stove enameled paint on both sides as per MoRD specifications. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

23317

23317.97

... More
Providing and fixing of retro-reflectorised logo board at different locations of road asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701- 600mm x 600mm size logo and sign board of 1100x300mm

3

17899

5966.37

... More
Traffic Signs- Retro-reflective Traffic Signs - Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701- 600mm equilateral triangle board

36

138447

3845.75

... More
Traffic Signs- Retro-reflective Object hazard marker of 300mm x 900mm size - Providing and fixing of retro-reflectorised Object hazard marker sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 300mm x 300mm x 450 mm, 450 mm below ground level as per drawings and Technical Specification Clause 1701

24

63815

2658.98

... More
Traffic Signs- Retro-reflective Single Chevron of 50cm x 60cm size - Providing and fixing of retro-reflectorised Chevron board marker sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701

12

52949

4412.47

... More
Traffic Signs- Direction and place identification sign upto 0.90 sqm size board - Retro - reflective Traffic Signs - Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Tehnical Specification Clause 1701.

7.2

54402

7555.91

... More
Supplying and installation of delineator (Road way indicators) posts 80- 100cm high above ground level, pained black and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorised panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)

30

16150

538.34

... More
Kilometre Stone- Reinforced cement concrete M15 grade kilometre stone / local stone of standard design as per IRC:8 fixing in position including painting and priming etc.as per drawing and technical Specification clause 1703 - Ordinary Kilometre stone (pre-cast)

5

16787

3357.51

... More
Boundary Piller- Reinforced cement concrete M15 grade boundary pillers / local stone of standard design as per IRC:8 fixing in position including painting and priming etc.as per drawing and technical Specification clause 1704

14

12753

910.98

... More
Kilometre Stone- Reinforced cement concrete M15 grade kilometre stone / local stone of standard design as per IRC:8 fixing in position including painting and priming etc.as per drawing and technical Specification clause 1703 - Ordinary Kilometre stone (pre-cast) HM stone

40

38328

958.22

... More
Printing new letters and figures of any shade - printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give a even shade as per drawings and technical specifications clause 1701- English and roman

7800

9438

1.21

... More
Total Construction cost

11067.1

26706204

0.74

... More
Maintenance for 5 years

-

-

-

... More
Maintenance for first Year after completion

8012

168249

1

... More
Maintenance for second Year after completion

8012

192285

1

... More
Maintenance for third Year after completion

8012

240356

1

... More
Maintenance for fourth Year after completion

8012

721068

1

... More
Maintenance for fifth Year after completion

8012

1081601

1

... More
Total Maintenance cost

8012

2403559

1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.