Kerala State Nirmithi Kendra Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Nirmithi Kendra - KESNIK Tender
Civil And Construction
Building Construction
Eprocure
Opening Date30 Apr 2019
Closing Date14 May 2019
Tender Amount₹ 13,98,848
Costs
EMD
₹ 34,971Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_KSNK_276369_1Bid Award Id
ViewTender No
KSNK/TECH/NHEC/SCR-114Tender Authority
Kerala State Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
15.23.2
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres
lead.For thickness of tiles above 25 mm and up to 40 mm
35.82
-
-
... More
15.56
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
60.4
-
-
... More
15.12.1
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats,
architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
2
-
-
... More
11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and
shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints
with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
60.4
-
-
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
10.58
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
6.26
-
-
... More
7.1.1
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement
concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth
level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.64
-
-
... More
50.6.1.8 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available
size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in:
CM 1:6 ( 1 cement : 6 coarse sand etc complete
10.09
-
-
... More
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders bressumers and cantilevers
16.82
-
-
... More
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth
and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :
3 graded stone aggregate 20 mm nominal size)
1.94
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
193.5
-
-
... More
9.48.2
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden
frames with rawl plugs screws etc
189.07
-
-
... More
21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium window, ventilators and
partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM
gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as
per specifications, drawings and direction of Engineer-in-Charge complete.
10.8
-
-
... More
10.6.1
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked
together through their entire length and jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push
and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1
and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick
top cover
11.88
-
-
... More
10.8.1
Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding
10.00 sqm and upto 16.80 sqm in the area
11.88
-
-
... More
13.7.2
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
125.08
-
-
... More
15.28.1
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50
metres lead of :G.S. Sheet
114.72
-
-
... More
10.16.1
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including
cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete.Hot finished welded type tubes
519.12
-
-
... More
9.50
Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per
sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with
approved steel primer all complete.
24.97
-
-
... More
11.18.1
Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of
steps not exceeding 30 cm in height , on 12 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand),
jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and
polishing complete with tiles of :Light shade pigment using white cement
41.47
-
-
... More
Providing insulating the room as following specification--Type of insulation for roof _300 mm high density
PUF Panels.The thickness of covering sheet is 0.50mm including powder coating the surface and
erection charges etc complete.(Add 5% wastage)
131.91
-
-
... More
13.46.1
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied
@ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
78.56
-
-
... More
13.60.1
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new work
51.63
-
-
... More
13.43.1
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
125.08
-
-
... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or
more coats on new work
95.17
-
-
... More
Providing false ceiling with TKT Panel 7.5mm thick fitted of aluminium or GI grids screwded to slab or
being using channels , tees etc and other necessary fixtures including cost of all materials and labour
charges etc complete
77.47
-
-
... More
14.54.1
Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give
even shade:One or more coats on old work
46.67
-
-
... More
Supplying and fixing 150 mm PVC gutter pipe on end of proposed GI roofing using GI clamp including all
labour charges ,cost of materials etc complete
15
-
-
... More
Supplying and fixing 75mm dia down water pipe and other accessories
25
-
-
... More
Providing and fixing uPVC moulded fittings/ accessories for Rigid uPVC pipes, including jointing with
uPVC solvent cement - 75mm dia Bend
6
-
-
... More
Providing and fixing uPVC moulded fittings/ accessories for Rigid uPVC pipes, including jointing with
uPVC solvent cement - 75mm dia Elbow
6
-
-
... More
ELECTRICAL WORKS
-
-
-
... More
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper
conductor single core cable etc as required.Group C
20
-
-
... More
1.12
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single corecable in
surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulatedcopper
conductor single core cable for loop earthing as required
100
-
-
... More
2.3.2
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
2
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
3
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
3
-
-
... More
1.14.2
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5
sq. mm + 1 X 2.5 sq. mm earth wire
150
-
-
... More
5.2
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry
enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt
as required
1
-
-
... More
1.27.4
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
3
-
-
... More
1.28.4
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.6 Module
3
-
-
... More
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
5
-
-
... More
1.14.4
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6
Sq.mm + 1 x 6 sq.mm earth wire
60
-
-
... More
1.14.6
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 16
sq. mm + 1 X 6 sq. mm earth wire
35
-
-
... More
5.19
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing
surface/ recessed conduit/ submain wiring/ cable as required.
35
-
-
... More
2.14.3
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent
circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB
complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
3
-
-
... More
Supplying and fixing 6 A to 32 A ratings, SP MCB, and other accessories
12
-
-
... More
Supplying and fixing 3'' dia punch light with LED bulb and other accessories
6
-
-
... More
Supplying and fixing 1 feet x 1 feet sq. type double pin type LED (24 Watts) mirror optics and all other
accessories etc., complete
6
-
-
... More
Supplying and fixing 12 " Exhaust fan and other accessories
2
-
-