Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 27,744Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Vanchikulam Nature Park Project, Thrissur (additional Work)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KSNK_692927_1Bid Award Id
ViewTender No
KSNK/TECH/THRS/VPTA-154R1/2024Tender Authority
Kerala State Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
25.7: Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
60
-
-
... More
25.3: Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
9
-
-
... More
Ticket counter, Cafeteria cum Boat deck building
-
-
-
... More
25.7: Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
16
-
-
... More
Electrical Work
-
-
-
... More
1.17.1: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
200
-
-
... More
1.17.2: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
300
-
-
... More
1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
100
-
-
... More
1.17.6: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
50
-
-
... More
1.17.8: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
20
-
-
... More
1.17.11: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
50
-
-
... More
1.17.13: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
10
-
-
... More
1.17.20: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
10
-
-
... More
1.17.29: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
10
-
-
... More
1.21.1: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
200
-
-
... More
1.21.2: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
50
-
-
... More
1.21.4: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.40mm
5
-
-
... More
90.9.1.1: Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
80
-
-
... More
90.9.1.7 : Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
6
-
-
... More
1.24.1: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
46
-
-
... More
1.24.3: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
... More
1.24.4: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
15
-
-
... More
1.24.5 :Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4
-
-
... More
1.27.1: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
6
-
-
... More
1.27.2: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
5
-
-
... More
1.27.3: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2
-
-
... More
1.27.4: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
... More
1.27.5: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
6
-
-
... More
1.33: Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required
20
-
-
... More
2.3.3: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door
3
-
-
... More
2.10.1: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
28
-
-
... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
1
-
-
... More
2.11: Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
10
-
-
... More
2.12.1: Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
2.13.1: Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.14.2: Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
... More
2.15.2: Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
5.4: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
14.1: Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
1
-
-
... More
14.7: Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
0.2
-
-
... More
14.11: Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
0.2
-
-
... More
14.12: Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
4
-
-
... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
3
-
-
... More
5.15: Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10
-
-
... More
90.3.11:Conveyance, installation, testing and commissioning of surface mounting down light fittings of all types directly on ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
38
-
-
... More
90.3.13 : Conveyance, installation, testing and commissioning of ornamental wall light fittings of all types directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages,
colour washing etc as required.
6
-
-
... More
90.3.14: Conveyance, installation, testing and commissioning of foot light fittings / skirt light of all types directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.
8
-
-
... More
90.3.23.5.3 : Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessories duly wired up for use on 230 V AC .Surface mounting LED 20W LED Batten with out put 2000 lumen for use on 250V AC supply.
2
-
-
... More
90.15.4.5: Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2
-
-
... More
od321571/2022_2023: Supplying and fixing hensil make junction box -IP65 of size 300x150x77 mm ) on the wall using anchor bolts etc as required
10
-
-
... More
od321572/2022_2023: Supplying and fixing hensel make cable junction box IP 66 with integral membrances/metric knockouts for cable entry and fixing the same on wall using fhil plugs/steel screws etc as required .(130x180x77mm
hensil make )
4
-
-
... More
od321573/2022_2023: Supplying and fixing 400mm sweep wall fan complete with standard accessories and fixing the same on
wall using anchor bolt and nut etc and giving connection etc as required.
4
-
-
... More
od321574/2022_2023: Supplying and fixing 63A 2 way N/L on the existin meter box and giving connection etc as required.
1
-
-
... More
od321575/2022_2023: Supplying and fixing 63A HRC fuse base with 25A fuse in the existing box and giving connection etc as required.
3
-
-
... More
od321576/2022_2023: Supplying and fixing 63A TPN SDF HRC with 32 A fuse in sheet steel enclosur and fixing the same on the wall using anchor bolt and nut etc and giving connection etc as required.
1
-
-
... More
od321577/2022_2023: Supplying and fixing 12V 150W IP 67 LED drive on the existing box and giving connection etc as requied.(K lite 8193/equivlent make )
3
-
-
... More
od321578/2022_2023: Supplying and fixing IP 67 LED 12V 60W drive and giving connection etc as required .(K lite 8192/equivlent )
3
-
-
... More
od321579/2022_2023: Supplying and fixing 12w/mtr IP 67 LED strip with power chord,alu; prefoil,alu; clip,connector pin,inter connector etc and fixing the same on wall using necessary phil plug,steel screw etc as required.(K lite 7289 with accessories /equivlent make ).
50
-
-
... More
od321580/2022_2023: Supplying and fixing 2/1 mtr 2 way track with connected accessories like connector L/T etc and fixing the same on ceiling and giving connection etc as required.e pole
30
-
-
... More
od321581/2022_2023: Supplying 12 W LED track light fitting (K lite 3677/equivlent )etc. as required.
25
-
-
... More
od321582/2022_2023: Supplying non integral light fitting with driv10W LEDer etc as required .(K- light 4245 &8281/equivlent make )
6
-
-
... More
od321583/2022_2023: Supplying 12W LED out door light fitting K-Lite 4046/equivlent make etc. as required.
2
-
-
... More
od321584/2022_2023: Supplying 2x12W LED out door up &down light fitting K lite 3638/equivlent make etc as required.
2
-
-
... More
od321585/2022_2023: Supplying 12W LED hanging light (K lite Sona midi 2874/equivlent make etc. as required.
4
-
-
... More
od321586/2022_2023: Supply of 9 W IP 67 LED ground luminair fitting complete with accessories (K lite -4091/equivlent make )
2
-
-
... More
90.6.4.54: Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
10
-
-
... More
90.6.5.11: Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm
10
-
-
... More
90.11.1.14: Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
... More
90.12.9.2: Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
15
-
-
... More
90.12.37.2: Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KVgrade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6sq mm
20
-
-
... More
90.12.41.2: Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
40
-
-
... More
90.16.1.1: Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
120
-
-
... More
90.16.1.2: Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
80
-
-
... More
90.16.1.3: Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
50
-
-
... More
90.16.2.1: Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe (medium class)
8
-
-
... More
90.16.5.1: Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
60
-
-
... More
90.16.5.2: Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
10
-
-
... More
90.16.5.3: Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
10
-
-
... More
od320160/2022_2023: Fabrication, supply and insulation of dust and vermin proof wall mounting, hot press moulded SMC meter box of following sizes suitable for fixing KSEB meter, fuse unit. CT etc hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out
for the cable.Sintex make GS-MB 7450 /equivlent make )
1
-
-
... More
od320162/2022_2023: Supply and provding test joint for earthing system using 2 nos of the following strips including cutting and bending to shape ,drilling necessary holes and fixing to the watering pipe etc as required .br2x25x6mm
GI strip
2
-
-
... More
od320164/2022_2023: Supplying and providing 12x3 mm brass bolt and nut with washer etc as required .
30
-
-
... More
od320165/2022_2023: Supplying and providing 25x6 mm brass bolt and nut with washer etc as required .
12
-
-
... More
od320166/2022_2023: Supply of 22W LED surface mounted down light fitting as required (K-lite 3613/equivlent make)
1
-
-
... More
od320167/2022_2023: Supply and providing surge protection devise conforming to IEC61643 with type1+ 2,limp 12.5KA,Imax50KA 3P+N (4 pole) and fixing the same in the existing enclosure with DIN and giving connection as required
1
-
-
... More
od320170/2022_2023: Supply and providing 2.5 KG ,fire extinguisher on wall providing suitable hook etc as required (CO2)
2
-
-
... More
od320181/2022_2023: Supplying and providing 4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands using brass bolt and nut etc as required.
6
-
-
... More
od320184/2022_2023: Numbering/lettering in the main board / ceiling fan / exhaust fan/ fluorescent fittings/other light fittings etc as required.
50
-
-
... More
od320185/2022_2023: Supplying and providing 2 mm thick 3.3KV synthetic elastromeric fire retardant insulating sheet in front of the main board eta as required
2
-
-
Evaluation Notes How It Works ?