Kerala State Nirmithi Kendra Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Nirmithi Kendra - KESNIK Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Apr 2023
Closing Date24 Apr 2023
Tender Amount₹ 3,16,42,941 
Notes
Download

Costs

Summary

Construction Of Legal Metrology Office Cum Laboratory Complex Nattakam, Kottayam

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
20.2A.1 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-25 ofspecified diameter and length below pile cap, to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile tobe embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete,including removal of excavated earth with all its lifts and leads (length of pile for payment shall bemeasured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.600 mm dia piles

450

-

-

... More
20.6.2.1 Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test.

1

-

-

... More
20.6.2.2 Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

1

-

-

... More
od271816/2022_2023 Chipping of concrete materials from pile tops with manual Chisel and or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavitied including cleaning the exposed concrete surface and reinforcement with wire brush etc.. and disposal of debris for all lead and lifts, all complete as per direction of Engineer In Charge

34.47

-

-

... More
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

125.55

-

-

... More
2.26.1 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

16.74

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

173.12

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

22.17

-

-

... More
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

8.35

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

36.55

-

-

... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size)

227.3

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size )

48.39

-

-

... More
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

73900

-

-

... More
5.9.2 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

93.44

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

949.04

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

900.91

-

-

... More
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

524.44

-

-

... More
5.9.7 Centering and shuttering including strutting,etc and removal of form for: Stairs,(excluding landings)except spiral-staircases)

63.12

-

-

... More
50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

2.04

-

-

... More
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

144.39

-

-

... More
50.6.1.6 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

65.22

-

-

... More
50.6.3.2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

14.81

-

-

... More
50.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

1.4

-

-

... More
50.9.2.1 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge.using Anjili/ Jack wood

70

-

-

... More
50.9.4.1 Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneled or paneled and glazed shutters 25mm to 40mm thick using good quality Anjill/ Jack wood.

47.47

-

-

... More
50.9.5.1 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood 35 mm thick shutters.

32.25

-

-

... More
9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame

65.4

-

-

... More
9.122.2 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

22.68

-

-

... More
od271817/2022_2023 Providing and fixing pressed Steel windows and ventilators made out of 16G (1.5mm) thick prime quality TATA Galvano Steel sheets using profiles 82 x 60 or 62 x 42mm for window frames welded or assembled with 75mm stainless steel butt hinges, adjustable hold fasts, mortar guards, stainless steel Hooks, Eyes and stay hooks etc and welded or assembled with MS Grill of Dia 12mm rod @ 100mm C/C horizontally with 30x5 flat vertically per panel or as specified and inclusive of labor charges for fixing al window fittings duly with concrete mix etc, and applied with suitable primer and then painted with polyurethane paint of desired color or applied with Powder coating.

190.2

-

-

... More
od271818/2022_2023 Fixing standard glazing in steel doors, windows and ventilators, including fixing of float glass panes of 4mm thickness etc complete

197.8

-

-

... More
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

3829.12

-

-

... More
13.7.1 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

350.88

-

-

... More
13.16.1 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

1689.31

-

-

... More
13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

676.93

-

-

... More
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer.

5750

-

-

... More
13.45.1 Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

113.67

-

-

... More
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2400

-

-

... More
13.50.3 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanisd iron / steel works.

54.56

-

-

... More
13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats

3230

-

-

... More
13.85.1 Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood ) having VOC content less than 50 grams/ litre

141.05

-

-

... More
13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

195.61

-

-

... More
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm

783.61

-

-

... More
11.46.2 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

162.13

-

-

... More
11.48.2 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

212.85

-

-

... More
16.91.2 Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

155.45

-

-

... More
10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover.

25.6

-

-

... More
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

388.05

-

-

... More
10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

404.3

-

-

... More
8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

19.12

-

-

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required

50.84

-

-

... More
COMPOUND WALL

-

-

-

... More
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

21.24

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.38

-

-

... More
60.7.2 DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.

16.88

-

-

... More
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1.35

-

-

... More
50.6.2.2 Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

9.9

-

-

... More
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

3.55

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

1.7

-

-

... More
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5.6

-

-

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

19.6

-

-

... More
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

15.12

-

-

... More
13.33.1 Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

28.8

-

-

... More
13.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

189.98

-

-

... More
13.44.1 Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

190

-

-

... More
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

770

-

-

... More
10.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

497.49

-

-

... More
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

35.44

-

-

... More
1. Electrical Works

-

-

-

... More
90.2.1.1 Supply and wiring points according to IS732-1989 using rigid PVC conduit of minimum size 20mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade,including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket,brass bolt and nut crimping /soldering etc complete with suitable size modular type metal switch boxes,modular type front plates(white) etc. up to and including 6A modular type SP switches and making good the surface of wall,colour washing etc. complete.All The Terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose-Short point.

147

-

-

... More
90.2.1.3 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with specials conforming to IS 9537 part III1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacingnot exceeding 50cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No. 14 SWGbare copper,required quantity of copper earth socket,brass bolt and nut crimping/soldering etc complete with suitable size modular type SP switches and making good the surface of wall, colour washing etc.complete.All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties,tie mounts etc as required.(RoHS compliant modular accessories).Single control light point without ceiling rose-Short point

18

-

-

... More
90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes,modular type front plates(white)etc.. up to and including 6A modular type SP switches and making good the surface of wall,colour washing etc. complete.All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accesoories).Single control ceiling fan point with 6A,3 plate ceiling rose&with socket size stepped electronic regulator-Short point.

30

-

-

... More
90.2.1.6 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/soldering etc complete with suitable size modular type metal switch boxes,modular type front plates(white)etc.. up to and including 6A modular type SP switches and making good the surface of wall,colour washing etc. complete.All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accesoories).Combined plug point with 6 A,5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points.

26

-

-

... More
od1587140/2021_2022 Supply and fixing angle/ straight brass linked skirt type,bakelite batten holder with 20mm polished shade with 9W LED and giving connection etc as required

18

-

-

... More
od1587141/2021_2022 Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body,epoxy powder coated,heat resistant prismatic glass cover with 9W LED to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 crore round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.(Mepro/Philips/Crompton/Bajaj Make)

7

-

-

... More
90.3.20.3 Supply& Installation of light fittings on TW round blockbrSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 crore copper conductor flex wire conforming to relevant ISS and giving connections as required.1200mm 1X20W LED Lamp with box type fixture.

6

-

-

... More
90.3.21.3 Supply & Installation of light fittings on 'C/U' shaped flat iron bracketbrSupply,conveyance,installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos.'C/U' brackets made from 20X3 mm MS flat,painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required .1200 mm 1 X 20W LED Lamp with box type fixture

71

-

-

... More
90.3.24.3 Supply & Installation of light fittings on ball & socket arrangement with 19mm down rodbr 'Supply,conveyance,installation,testing and commissioning the light fittings of following types made of .5mm thick CRCA ,sheet accessories and lamps etc.including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2X30 cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20 W LED Lamp with box type fixture.

18

-

-

... More
od1587142/2021_2022 S&F recess mounted LED ceiling light DNI72 D LED 15 S 1500 Lumen 6500 PSU W including giving connections(Photo band Philips make)

15

-

-

... More
od1587334/2021_2022 Supply of recess mounting type 12 W, LED RECESSED flat panel light fitting Crompton LSCSM-12W-CDLNW/WW or equivalent philips make with Profiled and flat diffuser,complete with all control accessories dulywired

2

-

-

... More
90.15.4.2 Supply Conveyance,Installation,testing and commissioning of 36/40 W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load,internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%,power factor greater than 0.98,RoHS compliant,duly wired up for use on 230 V AC supply.Driver compartment should be seperately accessible for maintenance(LM 79&80 certificates from NABL accredited Third party tab to be produced mentioning chip manufacturer)

4

-

-

... More
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

30

-

-

... More
od1587143/2021_2022 Supply and installation of 1200mm sweap ceiling fan with standard accessories with out regulator including giving connection with 16/0.20mm 3 core round copper conductor flexible chord etc as required.(Crompton (High speed)/Havells(SS-390)

30

-

-

... More
od1587144/2021_2022 Supply, ,installation,testing and commissioning wall mounting fan of the following sizes using mounting bracelets supplied along with the fan and giving connection with existing wire.350 mm sweep*(Almonard, Crompton or equallant make)

6

-

-

... More
90.4.8 Charges for cutting holes suitable for accomodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

12

-

-

... More
od1587145/2021_2022 Supply and installation of 150 mm medium duty 2300 rpm, 4 leaf exhaust fan in metal frame(Almonard/Crompton make) in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20. mm 3 core round copper conductor flexible chord etc required.

12

-

-

... More
90.6.10.1 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 20mm.

750

-

-

... More
90.6.10.2 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm.

600

-

-

... More
1.17.2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.2X 1.5 sq.mm

120

-

-

... More
1.17.4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required 4X 1.5 xsq .mm

50

-

-

... More
1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface /recessed steel/ PVC conduit as required. 6X 1.5 sq. mm

50

-

-

... More
1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface /recessed steel/ PVC conduit as required. 2X2.5 sq.mm

250

-

-

... More
1.17.13 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface /recessed steel/ PVC conduit as required. 4X2.5 sq.mm

160

-

-

... More
1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface /recessed steel/ PVC conduit as required. 6X2.5 sq.mm

160

-

-

... More
1.17.20 Supplying and drawing following size of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required .2X4 sq.mm

80

-

-

... More
1.17.22 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required .4x4 sq. mm

150

-

-

... More
1.17.29 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/PVC conduit as required .2X6 sq.m

60

-

-

... More
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

2000

-

-

... More
od1587146/2021_2022 Supply and providing RJ computer jack

63

-

-

... More
90.9.2.1 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476& 4678 on surface/ recess including cutting the wall and making good the damages in case of recessed installation as required.100X50 mm CMS with base and lid

100

-

-

... More
90.9.2.2 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider

100

-

-

... More
90.9.2.3 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree

10

-

-

... More
90.9.2.5 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

10

-

-

... More
90.9.2.8 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required.End Cap

10

-

-

... More
90.9.2.12 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required..

62

-

-

... More
90.9.2.14 Supply and fixing 100X50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/BS 476&4678 on surface/recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box

36

-

-

... More
1.27.1 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular ]switches in recess etc as required .1 or 2 Module(75mm X 75MM)

16

-

-

... More
1.27.2 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module(100mm X 75 mm)

53

-

-

... More
1.27.5 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module(125mmX125mm)

27

-

-

... More
1.24.1 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc . As required .5/6 amps switch

152

-

-

... More
1.24.3 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc . as required.15/16 amp switch

26

-

-

... More
1.24.4 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.3 pin 5/6 amp socket outlet

152

-

-

... More
1.24.5 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.6 pin 15/16 amp socket outlet

34

-

-

... More
od1591219/2021_2022 Supplying and fixing modular DP switch with indicator on the existing modular plate & switch box including connections but excluding modular plate etc. as required 20 amp DP switch with indicator

8

-

-

... More
2.3.4 Supplying and fixing following way, single pore and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar , neutral bus bar, earth bar, din bar, interconnections, powder painted including etc. as required.(But without MCBIRCCB/Isolator 16 way, Double door

3

-

-

... More
90.11.1.10 Supply and installation of sheet steel,phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar,neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages,colour washing etc. as required4 way (8+12)-three phase double cover(IP42/43)

8

-

-

... More
90.11.1.15 Supply and installation of sheet steel,phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar,neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages,colour washing etc. as required6 way (8+18)-double cover TPN vertical DB with provision for fixing 4P MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB as outgoing(IP42/43)

5

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.Single pole.

102

-

-

... More
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.Triple pole.

20

-

-

... More
2.12.1 Supplying and fixing following rating,double pole,240 volts, isolator in the existing MCB DB complete with connections,testing and commissioning etc.as required.40 amps

4

-

-

... More
2.13.1 Supplying and fixing following rating,four pole,415 volts, isolator in the existing MCB DB complete with connections,testing and commissioning etc.as required.40 amps

13

-

-

... More
2.15.2 Supplying and fixing following rating,four pole,(three phase and neutral), 415 volts,residual current circuit breaker(RCCB)having a sensitivity current 30 Ma in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps

13

-

-

... More
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms,making good the damages, colour washing eyc. as required 4 core 16 sq mm with factory made clamp

60

-

-

... More
90.12.7.42 Supply,laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required . 4 core 25 sq mm. with factory made clamp.

25

-

-

... More
90.12.7.44 Supply,laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required . 4 core 50 sq mm.

15

-

-

... More
9.1.33 Supply and making and termination with brass compression gland and aluminium lugs for the following size of PVC insulated and PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade as required .4X 16 sq.mm(28mm)

6

-

-

... More
9.1.34 Supplyinbg and making and termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 25 sq,mm(28mm

4

-

-

... More
9.1.36 Supplyinbg and making and termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required 4 X 50 sq,mm (35mm).

2

-

-

... More
od1587147/2021_2022 Earthing with G.I. earth pipe 2 metre long 40mm dia (medium class) including providing 12 mm dia drilled holes minimum 20 nos along the entire length in alternate arrangement providing 40X25 mm GI reducer at top and test joint using 2 nos, 25X3mm GI Strip minimum size 25cm suitably shaped and tightly clamped to the pipe electrode using 25X6 mm steel bolts nut and washer and providing 2 nos,6 mm dia drilled holes for clamping and bolting earth lead, and making masonry champer with cover plate having locking arrangement and etc.(Charcoal and salt as required shall be filled at 30 cm dia around the earth electrode)

2

-

-

... More
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required 2.00mm copper conductor(14 SWG)

1100

-

-

... More
90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required2.65 mm copper conductor (12 SWG)

250

-

-

... More
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor(10 SWG)

30

-

-

... More
90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimping rtc. as required 2.00 mm (14 SWG)

40

-

-

... More
90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimping rtc. as required.2.65 mm (12 SWG)

20

-

-

... More
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm(10 SWG)

16

-

-

... More
od1587148/2021_2022 Providing and fixing 25mm X 3mm copper strip on surface or in recess for connections etc .as required.

0.25

-

-

... More
od1587149/2021_2022 Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc.as required including drilling necessary holes as required.

90

-

-

... More
90.3.18.1 Supply,fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape/cut and welded to shape and fixing the same to wall /parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps

20

-

-

... More
od1587150/2021_2022 Supply and providing anchor bolt hook type on wall/parapet for binding KSEB Service connection cable as required.

1

-

-

... More
od1590316/2021_2022 Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availing Three phase service connection/Load regularization.

1

-

-

... More
od1587152/2021_2022 Aluminium anodised Danger Notice Board of size 150X100 mm. with inscriptions(both in English and Malayalam) and conventional Skull and Bone in Red Colour.

1

-

-

... More
od1587277/2021_2022 Supply and installation of dust and Vermin proof mounding mounting box SINTEX make GSMB-7450 or nearest make with base plate suitable to fix pump motor starter and other accessories on existing angle iron support using necessary nut bolt etc.

1

-

-

... More
od1587154/2021_2022 Supplying and fixing 100/200A bakelite fuse with HRC fuse link and giving connections in the existing meter board/panel.

3

-

-

... More
od1587155/2021_2022 Supplying and fiixng 63/100/200A, 2 Way neutral links mounted on DMC/SMC base and giving connections in the existing meter board/panel.

1

-

-

... More
od1587156/2021_2022 Supplying and fixing 63A backelite fuse with HRC fuse link and giving connections in the existing meter board/panel

3

-

-

... More
od1587157/2021_2022 Fabrication,supply,conveyance,installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicletype MV panel board conprising of the following components/devices & complying to IS 8623,Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623(with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility,bus bar chambers, hinged doors for all switch gear compartments,earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps,bus bar interconnection etc,detachable covers for bus bar chamber and cable alley,powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication.Angels/flats/slotted angels etc shall not be used for the fabrication of panel assembly.The measurements should be taken the area of the complete sheets used for panel board including partitions, folding shrouding etc. including Fixing all required switch gear, control wiring etc.

1

-

-

... More
od1587158/2021_2022 Supply and providing 2mm SMC sheet as shrouding for bus interconnection/terminations etc. including required nut & bolt etc.

1

-

-

... More
90.14.3.1 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/2.00mm sheet

9

-

-

... More
90.14.3.3 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardSupply and providing 'U' section PVC beeding in the panel board.

9

-

-

... More
90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75X40 mm rolled steel channel(ISMC)

30

-

-

... More
90.14.10.5 Supply,conveyance and fixing the following types & current rated control gears& switch gears conforming to IS 13947 suitable for 440 V,50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL&SC

6

-

-

... More
90.14.10.13 Supply,conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200 A, 35/36 kA(Ics=100%Icu),4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL&SC.

1

-

-

... More
90.14.11.2 MCCB Accessories Supply and fixing one number earth fault Relay up to 125A to 200A with CBCT.

1

-

-

... More
90.14.6 Supply and providing copper bus bars including finger type SMC bus bar suppports in the bus chamber, suitable size nut & bolt,providing heat shrink sleeves etc. as required

960

-

-

... More
90.14.7 Supply and providing copper earth bus in the panel board

365

-

-

... More
od1587159/2021_2022 Supply and fixing of Red,Green,Black,Yellow,Orange, colours LED indicator,AC/DC , 22.5 mm cut out dia

3

-

-

... More
od1587160/2021_2022 Providing Multi function meter to read: V,A,F,3 phase accuracy class 1

1

-

-

... More
od1587161/2021_2022 Supply and installation of 100/125 A,415 V,50 Hz,AC 23 A duty,4 pole on-load change over switch in sheet steel enclosure

1

-

-

... More
od1587163/2021_2022 Carrying out control wiring for panel with normal meters and indication lamps alone with normal meters and indication lamps alone with 650/1100V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferrules for the proper identification of the wiring,keeping the wiring firm by suitable tie/tie mounts/PVC duet etc as required. 6.00 sq mm single run with required sockets.

10

-

-

... More
od1587164/2021_2022 Carrying out control wiring for panel with normal meters and indication lamps alone with normal meters and indication lamps alone with 650/1100V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferrules for the proper identification of the wiring,keeping the wiring firm by suitable tie/tie mounts/PVC duet etc as required.1.50 sq mm single run with required sockets.

30

-

-

... More
od1587167/2021_2022 Supply and fixing CAT-6 24 port enhanced modular type patch panel for interconnecting servers and clients including termination charges.

4

-

-

... More
od1587/168/2021-2022 Supply and installation of 16 Port 10/100/1000 Mbps rack mountable switch Make: tp -link TL-SG 1016 D

4

-

-

... More
od1587169/2021_2022 Supply and fixing of 19", 4U, 500 MM Depth Wall Mount Rack with Front Glass door, cooling fan 90cm,NVRS, 1 No Power Distribution Unit Rack mounting type- 1 no, Cable Organizer /1U/Loop - 1No.(Netrack or equilent make)

4

-

-

... More
od1590373/2021_2022 Supply and fixing of 4 KVAR Voltage Stabilizer for split type AC unit with voltage rangeof 175-275 v and output range of 210-240 V

3

-

-

... More
od1590374/2021_2022 Supply and fixing of 25 mm 10kg/cm2 pvc drain water pipe with required accessories

20

-

-

... More
od1590375/2021_2022 Supply and providing following sizes of hard drawn copper refrigerent pipe with all accessories such as elbows, supports, clamps for inter connecting indoor unit and condensing unit including thermal insulation with rubber seal, foam sleeve, bracing , leak testing etc,- 1/2"

9

-

-

... More
od1590376/2021_2022 Supply and providing the 3/8 and 5/8 size soft drawn copper pipe extending the pipe between out door and indoor unit, including insulating the pipe using rubberised foam sleev 10mm thick brazing , leak testing etc.

9

-

-

... More
od1590377/2021_2022 Supply and providing bracket for fixing the AC unit(rate excluding GST)

3

-

-

... More
od1590378/2021_2022 Supply and installation testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230 v single phase AC supply, R32/non CFC refrigerant/r 410 A capable of performing functions like, cooling,dehumidifying, air circulating,copper piping 3m with insulation, filtering etc of the following capacity, microprocessor control with cordless remote control etc with one year warranty for machine and five year for compressor. 1.5 TR 5 Star single phase type split AC unit(O general/Blu star/Mitsubishi/Toshiba/Daikin) (Excluding GST)

3

-

-

... More
Plumbing & Sanitary Works

-

-

-

... More
51.19.ST4 Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid seperately) 4.35 to 50 flush capacity

3

-

-

... More
17.80 Providing and fixing white vitreous china battery based infrared sensor operated urtinal of approx.size 610X390X370 mm having pre & post flushing with water(250ml & 500ml consumption), having water inlet from ack side,including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

2

-

-

... More
17.78 Providing and fixing white vitreous china extended wall mounting water closet of size 780X370X690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting , of flushing capacity 3 litre/6litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.

10

-

-

... More
50.17.1.5 Supplying and fixing CP Health Faucet superior quality(Jagur or equivalent make) including cost of materials and labour charges etc complete as per the direction of Site Engineer-in-charge.

16

-

-

... More
17.7.3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P . Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550X400 mm with a pair of 15mm C.P.brass pillar taps.

7

-

-

... More
17.11.2 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets,cutting and making good the wall wherever required:Size 600X450X200mm

4

-

-

... More
17.32.4 Providing and fixing mirror of superior glass(of approved quality) and or required shape and size with plastic moulded frameof approved make and shade with 6mm thick hard board backing:Rectangular shape 1500X450mm

5

-

-

... More
od276819/2021_2022 Providing and fixing 125 mm CP Graitings for floor including cost of materials labourbretc complete

14

-

-

... More
18.7.2 Providing and fixing Chlorinated (PVC)pipes, having thermal stability for hot&cold water supply, includingfixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work- Exposed on wall20 mm nominal outer dia pipes

250

-

-

... More
50.18.8.3.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm pipe 10kgf/cm2

200

-

-

... More
50.18.8.4.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm pipe 10kgf/cm2

150

-

-

... More
50.18.8.5.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.40 mm pipe 6kgf/cm2

170

-

-

... More
50.18.7.6.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50mm dia 6 Kgf/cm2-Internal work-Expose on wall

120

-

-

... More
50.18.9.17.1 Providing and fixing PVC pipes including fixing the pipe with clamps/clipat 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6Kgf/cm2-External work-Exposed on wall

200

-

-

... More
50.18.9.8.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement,trenching,refilling&testing of joints complete as per direction of Engineer in Charge. 75 mm dia Kgf/ cm2

120

-

-

... More
50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/clips/at 1.00 m spacing. This includes jointing of pipes with one step PVC solven cement and testing of joints complete as per direction of Engineer-in-charge 110 mm dia Kgf/cm2-External work-Exposed on wall

290

-

-

... More
50.18.9.9.1 Providing and fixing PVC pipes including jointing of pipes with one step PVC solvent,trenching,refilling&testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

70

-

-

... More
50.18.9.10.1 Providing and fixing pipes including jointing of pipes with one step pvc solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.150 mm dia 6 Kgf/cm2

70

-

-

... More
24.2 Providng and fixing double scaffolding system(Cup lock type) on the exterior side of building/structure,upto 25 metre height,above ground level,including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube,placed 1.5 metre centre to centre, horizontal&vertical tubes joint with cup& lock system with M.S. Tubes,M.S. tube chakkus, M.S. clamps and stircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and / or applying chemical and removing it thereafter.The scaffolding system shall be stiffened with bracings,runners,connecting wirth the building etc,wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc.., complete as per directions and approval of Engineer-in-Charge.Note:-(1) The evolutional area of the scaffolding shall be measured for payment purpose , (2) The payment will be made once only for execution of all items of such works.

168

-

-

... More
4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size)

1.35

-

-

... More
2.6.1 Earth work in excavation by mechanical means(Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,lead up to 50 m and lift up to 1.5m,disposed earth to be levelled and nearly dressed. All kinds of soil.

38.15

-

-

... More
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached plasters, buttresses,plinth and string courses,fillets,columns,pillars,piers,abutments,posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3(1 cement :1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)

2.11

-

-

... More
5.9.12 Centering and shuttering including strutting,etc. and removal of form for: Well Steining

21.2

-

-

... More
5.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors,roots,landings,balconies and access platform.

26.41

-

-

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting,bending, placing in position and binding all complete upto plinth levelThermo-Mechanically Trated bars of grade Fe-500D or more

670

-

-

... More
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level :1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

4.58

-

-

... More
50.17.1.1 Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge

10

-

-

... More
50.17.1.3 Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge

10

-

-

... More
5.3 Reinforced cement concrete work in beams,suspended floors,roofs,having slope up to 15 landings,balconies,shelves,chajjas,lintels,bands,plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1:5:3(1 cement:1.5 coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal size).

0.63

-

-

... More
17.7.9 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660X460 MM WITH SINGLE 15mm C.P. brass pillar taps with elbow operated levers ISI marked

10

-

-

... More
8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4(1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

11.03

-

-

... More
50.9.11.2 Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc.complete(Frames, backing or studding to be paid seperately)as per the direction of site Engineer-in-charge.

45.15

-

-

... More
26.11 Providing and fixing concealed hinge of approved quality for 19-20mm thickdoor with stainless steel screws complete:

28

-

-

... More
9.114.1 Providing and fixing magnetic catcher of approved quality in cupboard/wardrobe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type

14

-

-

... More
9.165.3 Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.75 mm

14

-

-

... More
od277113/2021_2022 Providing and fixing Chromium finished pillar tap of approved quality conforming to IS standards and weighing not less than 690 gms.20mm nominal bore

20

-

-

... More
od277162/2021_2022 Providing and fixing Chromium finished Long Body Tap of approved quality conforming to IS standards andbr weighing not less than 690 gms.20 mm nominal bore

20

-

-

... More
Supply,Erection and Commisioning of Fully Automatic Stainless steel 8 Passenger Lift of Otis/KONE/Thyssenkrupp/Hitachi

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.