Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Special Repair Cum Renovation Of Rearing House No.2 At P2 Bsf Csb Pallatheri Palakkad
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KSNK_740208_1Tender No
KSNK/TECH/PKD/SRHP2CSB-33/2025Tender Authority
Kerala State Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
15.13.1
Taking out doors, windows and clerestory window shutters (steel or wood ) including
stacking within 50 metres lead:Of area 3 sq. metes and below
2
-
-
... More
15.7.4
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
4.17
-
-
... More
14.82
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c
malba all complete as per directions of Engineer-in-Charge
6
-
-
... More
15.23.1
Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
53.06
-
-
... More
15.56
Dismantling old plaster or skirting raking out joints and cleaning the surface for
plaster including disposal of rubbish to the dumping ground within 50 metres lead
47.31
-
-
... More
OD20729/2024-2025
cleaning of Floor and wall tiles with required Acid cleaner using 1 Liter per 5 square meter after cleaning the surface with brushes and finally with a piece of cloth including all materials and Labour charges etc completed
4.47
-
-
... More
5.9.6
Centering and shuttering including strutting, etc. and removal of form for:Columns,
Pillars, Piers, Abutments, Posts and Struts
42.24
-
-
... More
4.1.4
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2
coarse sand : 4 graded stone aggregate 40 mm nominal size)
4.08
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4
coarse sand : 8 graded stone aggregate 40 nominal size)
2.33
-
-
... More
14.1.1
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and
under, including cutting the patch in proper shape, raking out joints and preparing and
plastering the surface of the walls complete, including disposal of rubbish to the
dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine
sand)
45.23
-
-
... More
6.4.1
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to floor V level in all shapes and sizes
in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)
4.17
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
17.08
-
-
... More
10.25.2
Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74
Steel work welded in built up sections/framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.In gratings, frames, guard bar, ladder, railings,
brackets, gates and similar works
1582.68
-
-
... More
10.16.1
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses
etc., including cutting, hoisting, fixing position and applying a priming coat of
approved steel primer, including welding and bolted with special shaped washers etc complete.Hot finished welded type tubes
7511
-
-
... More
10.2
Structural steel work riveted, bolted or welded in built up sections, trusses and framed
work, including cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer all complete.
518.32
-
-
... More
12.50
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated
thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,
5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard film of 25 microns minimum to avoid
scratches during transportation and should be supplied in single length upto 12 metre
or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self
tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in
horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape wherever required.
703
-
-
... More
12.51.1
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+
0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%)
total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa
steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat
15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600
mm)
126.29
-
-
... More
13.61.1
Painting with synthetic enamel paint of approved brand and manufacture to give an
even shade:Two or more coats on new work
879.74
-
-
... More
14.43
Removing white or colour wash by scrapping and sand papering and preparing the
surface smooth including necessary repairs to scratches etc. complete
2150.08
-
-
... More
13.43.1
Applying one coat of water thinnable cement primer of approved brand and
manufacture on wall surface:Water thinnable cement primer
811.43
-
-
... More
14.63.1
Distempering with Ist quality acrylic washable distemper ( ready made) of approved
manufacturer and of required shade and colour complete as per manufacturers
specification.One or more coats on old work
1338.65
-
-
... More
14.66.2
Finish walls with Acryllic Smooth exterior paint of required shade:Old work (One or
more coat applied @ 0.90 ltr/10 sqm)
811.43
-
-
... More
13.7.2
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1
cement : 4 fine sand)
53.63
-
-
... More
11.36
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer -in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar
1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm,
including pointing in white cement mixed with pigment of matching shade complete.
37.82
-
-
... More
11.37
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick
cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with
white cement and matching pigment etc., complete
11.34
-
-
... More
8.2.1.2
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias
and similar locations, of required size, approved shade, colour and texture laid over
20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups, including rubbing,
curing, moulding and polishing to edges to give high gloss finish etc. complete at all
levels.Area of slab over 0.50 sqm
1.61
-
-
... More
21.1.1.1
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash
fasteners to be paid for separately):
For fixed portionAnodised aluminium (anodised transparent or dyed to required shad according to IS : 1868, Minimum anodic coating of grade AC 15)
271.5
-
-
... More
21.1.2.1
For shutters of doors, windows & ventilators including providing and fixing
hinges / pivots and making provision for fixing of fittings wherever required
including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid
for separately)Anodised aluminium ( anodised transparent or dyed to required shade
according to IS : 1868, Minimum anodic coating of grade AC 15)
485.9
-
-
... More
21.3.1
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm
thickness
65.7
-
-
... More
9.7.8
Providing and fixing panelling or panelling and glazing in panelled or panelled and
glazed shutters for doors, windows and clerestory windows (Area of opening for
panel inserts excluding portion inside grooves or rebates to be measured), Panelling
for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Fly proof
stainless steel grade 304 wire gauge with 0.5mm dia wire and 1.4 mm wide aperture
with matching wood beading
70.92
-
-
... More
9.1.1
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash
fasteners of required dia & length (hold fast lugs or dash fastener shall be paid
for separately).Second class teak wood
0.77
-
-
... More
9.5.1.1
Providing and fixing panelled or panelled and glazed shutters for shutters for doors,
windows and clerestory windows, including ISI marked M.S. pressed butt hinges
bright finished of required size with necessery screws, excluding panelling which will
be paid for separately, all complete as per direction of Engineer - in-charge.
Second class teak wood35 mm thick shutters
37.08
-
-
... More
9.7.4.1
Providing and fixing panelling or panelling and glazing in panelled or panelled and
glazed shutters for doors, windows and clerestory windows (Area of opening for
panel inserts excluding portion inside grooves or rebates to be measured), Panelling
for panelled or panelled and glazed shutters 25 mm to 40 mm thick:
Ply wood 7 ply, 9 mm thickDecorative plywood one side decorative veneer and
commercial veneer on other face (Type I) conforming to IS 1328 BWR Type
12.5
-
-
... More
9.97.2
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not
less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,
with necessary screws complete:250x10 mm
30
-
-
... More
9.97.5
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not
less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,
with necessary screws complete:100x10 mm
4
-
-
... More
9.100.1
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or
shade, with necessary screws etc. complete:125 mm
12
-
-
... More
9.165.1
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
45
-
-
... More
9.96.1
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required
colour or shade, with nuts and screws etc. complete:300x16 mm
25
-
-
... More
9.96.2
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required
colour or shade, with nuts and screws etc. complete:250x16 mm
4
-
-
... More
OD20434/2024-2025
Providing and fixing 50mmx42mmx2mm door frame and 25 mm thick PVC flush
door shutter including cost of all materials and labour charges etc complete
7.14
-
-
... More
OD20676/2024-2025
Providing and fixing FLAIR GLASS (LABEL) Frameless wall mount Rectangular
Mirror (Large) of superior glass ( of approved quality) and of required shape and size
with polished glass: Rectangular shape 900x600 mm
2
-
-
... More
PLUMBING WORKS
-
-
-
... More
17.1.1
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm
Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including
flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with
all fittings and fixtures complete, including cutting and making good the walls and
floors wherever require:White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests
1
-
-
... More
17.2.1
Providing and fixing white vitreous china pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever), conforming to IS : 7231,
with all fittings and fixtures complete, including cutting and making good the walls
and floors wherever required:W.C. pan with ISI marked white solid plastic seat and
lid
1
-
-
... More
50.17.1.4
Supplying and fixing CP Health faucet good quality including cost of materials and
labour charges etc. complete as per the direction of site engineer-in-charge.
2
-
-
... More
OD20667/2024-2025
Providing and fixing Counter top wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Counter top Wash basin size 490x390x160 mm with a single 15 mm C.P. brass
pillar tap
2
-
-
... More
18.51.1
Providing and fixing C.P. brass long body bib cock of approved quality conforming to
IS standards and weighing not less than 690 gms.15 mm nominal bore
4
-
-
... More
18.53.1
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS: 893115 mm nominal bore
6
-
-
... More
50.18.8.2.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge.
Concealed work, including cutting chases and making good the wall etc. 20 mm pipe
10 Kgf/ cm2
15
-
-
... More
50.18.9.14.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm
dia 10 Kgf/cm2 - External work- Exposed on wall
20
-
-
... More
50.18.7.6.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm
dia 10 Kfg/cm - Internal work- Exposed on wall
20
-
-
... More
50.18.8.7.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work
including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
20
-
-
... More
50.18.9.19.1
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6
Kgf/cm2 - External work- Exposed on wall
30
-
-
... More
ELECTRICAL WORKS
-
-
-
... More
1.10.2
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
93
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required.
93
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
150
-
-
... More
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
78.52
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured
aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
50
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
100
-
-
... More
1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x
1.5 sq. mm
40
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
30
-
-
... More
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
30
-
-
... More
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
4 sq. mm
20
-
-
... More
1.17.24
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
20
-
-
... More
1.14.1
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
100
-
-
... More
1.14.2
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
30
-
-
... More
1.14.3
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
20
-
-
... More
1.14.4
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of
FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
20
-
-
... More
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.1 or 2 Module
(75mmX75mm)
5
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
10
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.3 pin 5/6 amp socket outlet
10
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as
required.5/6 amps switch
10
-
-
... More
1.27.3
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
4
-
-
... More
1.27.4
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4
-
-
... More
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.8 Module
(125mmX125mm)
2
-
-
... More
1.26
Supplying and fixing modular blanking plate on the existing modular plate &
switch box excluding modular plate as required.
10
-
-
... More
1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be
used in non residential buildings).
6
-
-
... More
1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps
modular socket outlet and 15/16 amps modular switch, connection etc. as required
22
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
2
-
-
... More
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical
DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/
TP MCB as outgoing (IP 42/43)
2
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
2
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.63
amps
2
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
2
-
-
... More
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
72
-
-
... More
90.3.20.3
Supply & installation of light fittings on TW round block<br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories
and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
18
-
-
... More
90.3.22.3
Supply & installation of light fittings on flat iron bracket<br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm
1X20W LED Lamp with box type fixture
2
-
-
... More
90.3.24.4
Supply & installation of light fittings suspended on ball & socket
arrangement with 19 mm down rod<br>
Supply, conveyance, installation, testing and commissioning the light fittings of
following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including
painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture
24
-
-
... More
90.3.10
Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required
7.2
-
-
... More
OD63804/2024-2025
Supply and fixing angle / straight brass lined modular Bakelite batten holder with 7W
LED lamp and giving connection etc as required
8
-
-
... More
OD63788/2024-2025
Supply, conveyance, installation, testing and commissioning of 1200mm sweep -
ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air
delivery minimum 210(cubic meter/ minute), 300mm down rod , 2 number canopies,
shackle kit, Copper winding, 3 number blades and all remaining accessories including
safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc.
complete as required 2025
17
-
-
... More
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as
required.
17
-
-
... More
OD63799/2024-2025
Supply, conveyance, installation, testing and commissioning of the following sizes of
exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the
damages etc. as required including giving connections with required length of
24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex
wire conforming to relevant ISS. 450 mm sweep, 900 rpm Heavy Duty Exhaust fan
working on 230 V A/C.
14
-
-
... More
OD65313/2024-2025
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fitting with deep drawn anodized aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable with 7 W LED to wall / ceiling including giving
connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3
core round copper conductor flex wire conforming to relevant ISS or extending the
original wiring and making good the surface as required
6
-
-
... More
90.15.4.5
Supply Conveyance, installation, testing and commissioning of 40W LED Flood light
output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make
Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge
protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,
acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS
compliant, duly wired up for use on 230 V AC supply. Driver compartment should be
seperatly accessible for maintenance (LM 79&80 certificates from NABL
accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
... More
2.1.2
Providing and fixing following capacity TP&N disconnector fuse switch unit
inside the existing panel board with ISI marked HRC fuses including drilling holes in
cubicle panel, making connections, etc. as required.63 Amp TP & N
4
-
-
... More
2.1.4
Providing and fixing following capacity TP&N disconnector fuse switch unit
inside the existing panel board with ISI marked HRC fuses including drilling holes in
cubicle panel, making connections, etc. as required.125 Amp TP & N
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%