Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Ambedkar Gramam Project For Sc Gramam,kurumbaloor
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KSNK_727630_1Tender No
KSNK/TECH/KTR/SCKUMBR-145/2025Tender Authority
Kerala State Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
60.7.1
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
87.42
-
-
... More
7.1.1
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
238.73
-
-
... More
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders bressumers and cantilevers
130.7
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
163.6
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2706
-
-
... More
50.2.26.1
Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
321
-
-
... More
51.2.3
Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling
the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
64.2
-
-
... More
16.1
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after
excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
321
-
-
... More
2.1.1
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
975
-
-
... More
2.Construction of RCC Culvert and RCC Retaining Wall at SC Colony Kurumbaloor
-
-
-
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
19.26
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
2.82
-
-
... More
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)
26.77
-
-
... More
5.9.6
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,
Abutments, Posts and Struts
138.64
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2250
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
26.76
-
-
... More
3.Construction of Well and Water Supply Project at SC Colony Kurumbaloor
-
-
-
... More
2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
140.25
-
-
... More
50.18.9.8.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
45
-
-
... More
50.18.9.7.1 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
115
-
-
... More
50.18.7.6.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
330
-
-
... More
50.18.9.4.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2
46
-
-
... More
50.18.9.3.2
Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2
413
-
-
... More
4.1.3
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size)
42.47
-
-
... More
18.51.1
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
20
-
-
... More
50.18.9.20.2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
10
-
-
... More
50.18.9.20.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 63 mm dia Bend
8
-
-
... More
50.18.9.20.10
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 63x50 mm dia Reducer
4
-
-
... More
50.18.9.21.2
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC
solvent cement -75 mm dia 45 degree Elbow
4
-
-
... More
50.18.9.21.5
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement -75x75x75 mm dia Tee
2
-
-
... More
50.18.9.21.10
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement -75x63 mm dia Reducer
5
-
-
... More
50.18.9.21
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 75 mm dia Elbow
4
-
-
... More
50.18.9.21.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 75 mm dia Bend
4
-
-
... More
od44072/2024_2025
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 32x25 mm dia Reducer
8
-
-
... More
od44073/2024_2025
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 50x32 mm dia Reducer
4
-
-
... More
od44074/2024_2025
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -50mm dia 45 degree Elbow
12
-
-
... More
od44075/2024_2025
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement -25 dia 45 degree Elbow
12
-
-
... More
od44076/2024_2025
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement -32 dia 45 degree Elbow
6
-
-
... More
od44077/2024_2025
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC
solvent cement - 50mm dia Bend
6
-
-
... More
18.32.1
Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common
burnt clay F.P.S (non modular) bricks of class designation 7.5
3
-
-
... More
18.18.3
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats
complete:25 mm nominal bore
1
-
-
... More
18.19.4.2
Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal
boreVertical
1
-
-
... More
18.98.7
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge.Valve Connector.For 48.60 mm outer dia X 50 mm nominal dia threaded
3
-
-
... More
18.97.11
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge.Male Thread Connector/ Adapter.For 48.60 mm outer
dia X 50 mm nominal dia threaded
3
-
-
... More
18.96.12
Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA G116 standard with V- profile or M- profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineering in -charge.Female Thread Connector/ Adapter.For 48.60 mm outer dia X 50 mm nominal dia threaded
3
-
-
... More
od44078/2024_2025
Supplying and fixing single phase submersible motor pump 1.5 HP including starter, 1" 1.50 "suction hose/pvc pipe ,Rope, D.P Switch,Electrical fittings & all other accessories ( all items branded) including
labour charges etc.complete.
1
-
-
... More
18.48
Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
6000
-
-
... More
2.9.2
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (requiring blasting)
3.91
-
-
... More
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
3.91
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.61
-
-
... More
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
9.84
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
625.68
-
-
... More
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
16.33
-
-
... More
2 Pond
-
-
-
... More
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
8.5
-
-
... More
2.9.1
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
12.31
-
-
... More
2.9.2
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (requiring blasting)
24.62
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
1.32
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
7.05
-
-
... More
5.9.12
Centering and shuttering including strutting, etc. and removal of form for:Well steining
32.22
-
-
... More
5.9.2
Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including
attached pilasters, butteresses, plinth and string courses etc.
23
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
513.6
-
-
... More
od46555/2024_2025
Conveying handling and lowering RCC ring etc.complete as per the directions of Engineer in Charge
18
-
-
... More
od46363/2024_2025
Filling with 20mm metal in between cement concrete ring and grand sides etc. complete as per the
directions of Engineer-In-Charge.
4.31
-
-
... More
60.2.2
Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including
conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete
45
-
-
... More
50.10.1
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete
35.12
-
-
... More
50.10.2
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete
11.59
-
-
... More
12.50
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as
approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape wherever required.
3.63
-
-
... More
16.70.1
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
0.75
-
-
... More
3 ELECTRICAL
-
-
-
... More
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
2
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1
-
-
... More
90.6.5.12
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq
mm
12
-
-
... More
90.14.1.1
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.brFabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for
panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
1
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
2
-
-
... More
od46317/2024_2025
Supplying, installing,testing and commissioning of wall mounted Single phase 2 wire energy meter with
poly carbonate body having range of 32 Amp with enclosure made out of powder coated fixing in surface/
recess with fuse unit 32 amp with neutral link, its interconnection etc. The enclosure shall have lockable
door with glass window and all mounting accessories etc.complete as required Including KSEB Charges
1
-
-
... More
4.Installation of Solar Street Lights in SC Colony Kurumbaloor
-
-
-
... More
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
3.46
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
1.15
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
3.46
-
-
... More
5.9.1
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
23.04
-
-
... More
51.18.12.8
Providing and fixing G.I. pipes complete with G.I. fittings (Cost of fittings to be paid separately)
External work - 80 mm nominal dia
56
-
-
... More
od46731/2024_2025
Providing and fixing Solar panel and light, solar panel with 20 Watts battery of capacity 24Ah, LiFePO4 type and 3.2V, 20 Watt LED light with 2360 lumens and including necessary PVC insulated wires, automatic power on-off facility and fit to Iron pole with screws & clamps,including the cost of fixing etc.