Kerala State Nirmithi Kendra Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Nirmithi Kendra - KESNIK Tender
Education And Training Services
Eprocure
Opening Date21 Aug 2024
Closing Date28 Aug 2024
Tender Amount₹ 14,52,193
Costs
EMD
₹ 36,305Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Setting Up Of Studio In Connection With Virtual Pre Examination Training In Ambedkar Bhavan Under Sc Department At Mannanthala Thiruvananthapuram
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KSNK_686891_1Bid Award Id
ViewTender No
KSNK/TECH/NHEC/SVSC-355R1/2024Tender Authority
Kerala State Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
9.126.1
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed
shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion
inside grooves or rebates to be measured). Panelling for panelled and glazed shutters 25 mm to 40 mm
thick.Marine plywood conformingto IS : 710
98.69
-
-
12.34
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass
wool conforming to IS: 8183, density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags,
fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire meh of 12.5 mm x 24 gauge wire
and mesh, for top most ceiling of builing
66.69
-
-
12.57
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183
having density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw,
rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of
Engineer-in-Charge
122.99
-
-
12.45.4
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5
mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50
mm of required length with nuts & bolts of required size and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which
the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips
of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm
long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing
to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing
tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two
coats of primer suitable for board, all as per manufacturer's specification and also including the cost of
making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably
fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding
the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having
approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge
and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC
value not less than 0.60.
212.1
-
-
9.1.3
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately).Kiln seasoned and chemically treated Hollock wood
0.04
-
-
9.20.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core
of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI
marked Stainless Steel butt hinges with necessary screws
5.35
-
-
od284636/2023_2024
Supplying and laying Coir mat flooring using .45m x .45m coir mat tiles including labour charges,
transportation, cost of material etc complete
68.73
-
-
13.48A.1
Finishing walls with 100% Premium acrylic emulsion paint having VOC lessthan 50 gm/litre and UV
resistance as per IS 15489:2004, Alkali & fungalresistance, dirt resistance exterior paint of required
shade (Company DepotTinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/
10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm.
227.18
-
-
13.68.1
French spirit polishing:Two or more coats on new works including a coat of wood filler
8.86
-
-
9.63.3
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws
etc. complete:150x10 mm
4
-
-
od284911/2023_2024
Providing and fixing heavy type hydraulic door closer with necessary accessories and screws etc
complete
2
-
-
9.76
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever
handles of approved quality with necessary screws etc. complete.
2
-
-
ELECTRICAL WORKS
-
-
-
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper
conductor single core cable etc as required.Group C
25
-
-
1.12
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single corecable in
surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulatedcopper
conductor single core cable for loop earthing as required.
150
-
-
1.14.2
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5
sq. mm + 1 X 2.5 sq. mm earth wire
150
-
-
1.14.9
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6
sq. mm + 2 X 6 sq. mm earth wire
75
-
-
1.14.6
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 16
sq. mm + 1 X 6 sq. mm earth wire
30
-
-
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
6
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
6
-
-
1.24.6
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.Telephone socket outlet
3
-
-
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
6
-
-
1.28.2
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.3 Module
6
-
-
2.3.2
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
1
-
-
2.5.3
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB
distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned
copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and
incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are
required.)12 way (4 + 36), Double door
1
-
-
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
10
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing,commissioning etc as required 40 amps
3
-
-
od285468/2023_2024
Supplying, installation, testing and commissioning of 2 tonne invertor split AC with 5KVA voltage
stabiliser and other accessories.
3
-
-
od285770/2023_2024
Supplying fixing of AC stand
3
-
-
od285771/2023_2024
Providing additional copper piping for erection of AC unit
9
-
-
od285000/2023_2024
Supplying and fixing 6'' dia punch light with LED bulb and other accessories
7
-
-
od285325/2023_2024
Supplying and fixing 1 feet x 1 feet sq. type double pin type LED (24 Watts) mirror optics and all other
accessories etc., complete
8
-
-
od285338/2023_2024
Supplying and fixing 3 watts LED pilot lamp including all labour charges cost of materials etc complete
3
-
-
od285363/2023_2024
Engaging electrician for grimbing the computer net work and dismantling old electrical fittings circuits and
etc
2
-
-
NETWORK CABLING
-
-
-
od285376/2023_2024
Providing network cabling using cat 6 cable through 1" case and caping and giving conncetion including
all labour charges materialcost,grimping and connecting etc, complete
100
-
-
od285380/2023_2024
Supplying fixing roset and grimping the ends etc complete
2
-
-
od285385/2023_2024
Supplying and fixing PATCH CORD 0.50M on bottom and grimping two ends
4
-
-
od285391/2023_2024
Supplying and fixing PATCH CORD 0.50M on top and grimping two ends
4
-
-
od285397/2023_2024
Supplying and fixing 1M PATCH CORD and grimping two ends
4
-
-
od285400/2023_2024
Supplying and fixing 2M PATCH CORD and grimping two ends
4
-
-
od285407/2023_2024
Supplying and fixing 3M PATCH CHORD and grimping two ends
4
-
-
od285408/2023_2024
Supplying and fixing patch pannel and giving connection
1
-
-
od285434/2023_2024
Supplying and fixing 8 port switch and giving connection
1
-
-
od285429/2023_2024
Supplying and fixing 4U rack and giving connection
1
-
-
od285437/2023_2024
Supplying and fixing RJ 45 Connection clip
20
-
-
od285443/2023_2024
Engaged a computer engineer for programming all network and commisioning etc. complete (1 Racks X
2000 = 2000)
1
-
-
TELEPHONE CABLING
-
-
-
od285539/2023_2024
Supplying and drawing two pair telephone cable through 1'' case and caping and giving connection
50
-
-
od285542/2023_2024
Supplying and fixing IO box set and giving connection
2
-
-
od285543/2023_2024
Supplying and fixing rose set box and giving connection
2
-
-
od285548/2023_2024
Suplying and fixing ordinary type telephone (BPL make) and other assessories
2
-
-
FURNITURE
-
-
-
od285591/2023_2024
Supplying executive table 1.8 m (JY1809)
1
-
-
od285595/2023_2024
Supplying executive type chair (High midback)
1
-
-
od285605/2023_2024
Supplying visitor chair with arm
10
-
-