Kerala State IT Infrastructure Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date15 Apr 2025
Closing Date19 May 2025
Tender Amount₹ 16,95,34,374 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder includes details of their experience, particularly in the format provided. The bidder should have a track record of completing or being involved in projects of a certain scale or nature. The bidder needs to provide information on similar executed projects during the last seven years, each costing more than Rs.4.31 Crores. For these projects, the bidder should provide details such as the name of the project, brief scope of the project, location of work, details of the client, contract number and date, value of the contract at award, and value of work executed. Additionally, the bidder needs to provide information on key personnel, including their years of experience, for positions such as Project Manager, Site Engineer Civil, Site Engineer – MEP, Site Engineer – Quality Control/Billing, and Supervisors. For ongoing projects, the bidder needs to provide the uptodate percentage progress of work. However, for completed projects, no specific percentage is mentioned. The value of similar works completed should be more than Rs.4.31 Crores. The bidder also needs to provide performance evaluation certificates for the prequalifying works, which should include details such as timely execution, quality consciousness, integrity in works, financial soundness, mobilization of sufficient manpower and materials, and general performance. The performance evaluation should be rated as Excellent, Very good, Good, Satisfactory, or Poor. At least three projects are required to be mentioned, with each project costing more than Rs.4.31 Crores.

Costs

Summary

Augmentation Of Infrastructure Facilities At College Of Engineering, Trivandrum

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

10

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

5

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

248.04

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

578.74

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

89.85

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

209.65

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

99.18

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

142.32

-

-

... More
od3836/2025_2026 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).<br>600 mm dia piles

1078.2

-

-

... More
od3838/2025_2026 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).<br>800 mm dia piles

1847.4

-

-

... More
od3842/2025_2026 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge.<br>Initial test ( Test Load 2.5 times the Safe capacity=2.5X120 T for 600 mm dia pilesy )

1

-

-

... More
od3844/2025_2026 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 ( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.<br>Initial test ( Test Load 2.5 times the Safe capacity=2.5X210 T=525 Tonne capacity )

1

-

-

... More
od3845/2025_2026 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge.<br>Routine test (Test Load 1.5 times the Safe capacity =1.5x120 for 600 mm dia piles )

1

-

-

... More
od3846/2025_2026 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge.<br>Routine test (Test Load 1.5 times the Safe capacity=1.5X210=315T)

1

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

1292

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

100

-

-

... More
CONCRETE WORKS

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

103.27

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

72.57

-

-

... More
od3816/2025_2026 : Providing & applying a coat of residual petroleum bitumen of grade of VG-10<br>of approved quality using 1.7kg per square metre on damp proof course after<br>cleaning the surface with brushes and finally with apiece of cloth lightly<br>soaked in kerosene oil.

72.57

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

110.8

-

-

... More
50.4.1.1 : Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc.

32.22

-

-

... More
R.C.C. WORKS

-

-

-

... More
od3828/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).<br>All work upto plinth level<br>

366.94

-

-

... More
od3831/2025_2026 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)<br>All work above plinth level upto floor V level.

1111.01

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

90.13

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

26.31

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

166731.94

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

209467.32

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

631.34

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

270.24

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

3054.1

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

3407.44

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

1951.14

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

184.65

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1051.36

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

496.09

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

56.24

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

1233.76

-

-

... More
MASONRY AND PARTITION WORKS

-

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

32.45

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

1.92

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

28.95

-

-

... More
od3833/2025_2026 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level up to floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

91.03

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

747.11

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

33.31

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

1213.82

-

-

... More
JOINERY WORKS

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

2289.08

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

2289.08

-

-

... More
od3813/2025_2026 : Providing and fixing glazing in aluminium door, window,ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With high performance glass panes of 6 mm thickness meeting GRIHA compliance of overall value "VLT shall be between 0.6 to 0.7, SHGC ≤0.68

364.3

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

21.6

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

21.6

-

-

... More
od3823/2025_2026 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

374

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

1008

-

-

... More
10.27.3 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm

618

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m2 . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

68.2

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately

18.96

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).

4.74

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

6

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

3.48

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters

17.76

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

17.76

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

17.76

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

154.77

-

-

... More
9.125 : Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.

4.41

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

82

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

82

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

77

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

164

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

206

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

103

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

474

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

547.4

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

143.04

-

-

... More
50.9.1.2 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood

1.98

-

-

... More
9.20.3 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard ) including ISI marked nickel plated bright finished M.S. piano hinges IS : 3818 marked with necessary screws

316.68

-

-

... More
9.79.4 : Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.75 mm

468

-

-

... More
STEEL WORKS

-

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

432

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

6033.75

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

160

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1519.2

-

-

... More
FLOORING WORKS

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1955.53

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

258.25

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

33.74

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

210.45

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

34

-

-

... More
od3827/2025_2026 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

365.97

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

1188.13

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

34.56

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

22.2

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

7.62

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

54.24

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

428.5

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

462.02

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

177.09

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

1112.09

-

-

... More
FINISHING WORKS

-

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3679.51

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

11260.17

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

12007.39

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

12007.39

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

2933.35

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

1446.29

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

1751.21

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

48.3

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

181.01

-

-

... More
od3843/2025_2026 : Forming groove of uniform size from 12x12 mm and upto 25 x 15 mm in the top layer of plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer -in-Charge.

258.4

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/ Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

41.8

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

300.86

-

-

... More
MISCELLANEOUS BUILDING WORKS

-

-

-

... More
od3811/2025_2026 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

547.53

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

149

-

-

... More
od3814/2025_2026 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge.<br>600x600mm

4

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

24

-

-

... More
od3819/2025_2026 : Supplying and installing automatic organic waste converter with capacity of 50kg/day of size 5.5ft x 2.7ft x 4.7ft of approved make or equivalent etc complete all as per manufactures specification and directions of Engineer in charge.(1 HP 1440RPM,3 phase connection,SS-304 holding tank,1.5mm thick MS sheet with holding tank housing, SS 304 shaft and blades).

1

-

-

... More
PAVING WORKS

-

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

29.4

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

12.25

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

12.25

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

113

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

84.75

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

565

-

-

... More
30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

145

-

-

... More
od3822/2025_2026 : Supplying and planting healthy plants of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of plants size 25 cm of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

2

-

-

... More
od3825/2025_2026 : Providing and planting of Azadirachta indica ( Neem ) of height 120-130cm<br>in big polybag of size 25 cm including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

8

-

-

... More
od3826/2025_2026 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to at the time of planting)<br>Trees<br>Cassia fistula.

2

-

-

... More
od3829/2025_2026 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.(Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to60cms at the time of planting)<br>Trees<br>Ficus Benjamina.

10

-

-

... More
od3830/2025_2026 : Supply and planting of Saraca indica (Sita Ashok)plant of height 105-120 cm. in big poly bags of size 25 cm including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge as per direction of the officer-in-charge.<br> <br>

2

-

-

... More
od3832/2025_2026 : Supplying and planting healthy plants of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge.

4

-

-

... More
od3834/2025_2026 : Providing and planting Raphis palm having height of 1.5 to 1.65 m with 40 to 60cm lush green suckers well developed fresh and healthy foliage leaves in 40cm size of earthen pot /chlai/tray asnd as direction of the engineer in charge.

10

-

-

... More
od3835/2025_2026 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 120 to 150 cms, shrubs to have a height of 30 to at the time of planting) Shrub - Bougainvillaea glabra

5

-

-

... More
od3837/2025_2026 : Providing and planting Schefflera high colour having height 25cm to 40cm, well developed with fresh and healthy foliage including maintenance (as and when required) etc complete all as per direction of Engineer in charge.

5

-

-

... More
od3839/2025_2026 : Providing and planting of Dracaena song of india specimen plant (three in one) having of height 60cm and above well developed ,fresh and healthy with good foliage in big polybag of size 25 cm including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge .

10

-

-

... More
od3840/2025_2026 : Providing and planting of impatiens in different colour well developed fresh and healthy (three in one) well bloomed in including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge .

10

-

-

... More
od3841/2025_2026 : Providing and planting of Areca Palm plant, having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 20 cm size of Earthen pot / Plastic pot including including necessary maintenance of the plants (as and when required) at site as directed by Engineer in charge.

5

-

-

... More
RETAINING WALL WORKS

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

86.83

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

202.61

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

289.44

-

-

... More
od3820/2025_2026 : Supplying and laying good quality filter media (coarse aggregates of varying sizes from 53mm to 90<br>micron) brought from outside including cost of all materials, labour charges, transportation, loading,<br>unloading ,taxes etc complete as directed by the Engineer- in -charge. The work has to be executed as<br>per detailed specifications, and or as approved by Engineer - in - Charge.

118.2

-

-

... More
od3821/2025_2026 : Providing and fixing 110mm dia perforated pipes in filter media complete as directed by the Engineer-in-Charge. The rate including cost and conveyance of all materials, labour and fixing charges, etc.

75

-

-

... More
od3824/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. <br>All work above plinth level upto floor V level

50.45

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

5045.25

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

106.2

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

185.4

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

493

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

218.24

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

379

-

-

... More
Land development work

-

-

-

... More
od3810/2025_2026 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.<br>Ordinary rock

1312.5

-

-

... More
od3812/2025_2026 : Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in<br>depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,for all leads and<br>lifts within the site as per site requirement and direction of engineer in charge, disposed earth to be<br>levelled and neatly dressed.All kinds of soil

562.5

-

-

... More
od3818/2025_2026 : Filling available excavated earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, all lead and lift as directed by the Engineer in charge.

1050

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

825

-

-

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

9.52

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

22.22

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1.16

-

-

... More
od3815/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account) All work upto plinth level

3.8

-

-

... More
od3817/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account)All work above plinth level upto floor V level

2.8

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

18.72

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

22.4

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

60.39

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

200

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

548.68

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

593.36

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

22.46

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

593.36

-

-

... More
U G Sump-30M3

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

26.51

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

61.86

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

8.64

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

20.16

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

7.45

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

81

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.57

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

2529.97

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

8160

-

-

... More
od3899/2025_2026 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .Minimum cement content considered in this item is @ 340 kg/cum.<br> All work upto plinth level.

19.94

-

-

... More
od3900/2025_2026 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.

0.26

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

6.98

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

115.84

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

20.16

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

18

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

52

-

-

... More
od3902/2025_2026 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

93.52

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

1025.92

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

93.52

-

-

... More
od3903/2025_2026 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.65

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.43

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.43

-

-

... More
Pump room above sump tank

-

-

-

... More
od3898/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. <br>All work above plinth level upto floor V level

6.47

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

9.4

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

22.09

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

19.16

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

18.8

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

12.32

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

736.92

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

19.36

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

2.52

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

7.2

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

3

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

30.38

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

30.38

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

6.75

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

9

-

-

... More
od3901/2025_2026 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.<br>In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

101.25

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

112.14

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

32.65

-

-

... More
od3902/2025_2026 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

32.65

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

358.17

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

1223.25

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

79.27

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

43.43

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

43.43

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.

32.65

-

-

... More
Earth work

-

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

90

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

60.02

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

140.05

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

28.43

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

75.82

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

89.46

-

-

... More
od3915/2025_2026 : Disposal/stacking of building rubbish/ malba/ similar unserviceable, dismantled ,balance earth or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or within the site premises as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

110

-

-

... More
Concrete work

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

12.19

-

-

... More
RCC work

-

-

-

... More
od3911/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Note:- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).All work upto plinth level.<br>

36

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

0.2

-

-

... More
od3912/2025_2026 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete for all levels.<br>Thermo-Mechanically Treated bars of grade Fe-500D or more.

3620

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

12.49

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

36.68

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

163.61

-

-

... More
Steel work

-

-

-

... More
od3908/2025_2026 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

21.6

-

-

... More
od3910/2025_2026 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight<br>of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

2

-

-

... More
Finishing works

-

-

-

... More
od3909/2025_2026 : 15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels. <br>

138.7

-

-

... More
Miscellaneous works

-

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

84.8

-

-

... More
od3913/2025_2026 : Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete for internal work-exposed on walls as directed by the Engineer-in-Charge<br>110mm OD(6 kg/cm2)<br>

15

-

-

... More
od3914/2025_2026 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
Foundation

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1.79

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

0.2

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.6

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

4.88

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

198

-

-

... More
od3993/2025_2026 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)<br>All work upto plinth level

1.98

-

-

... More
SANITARY WORKS

-

-

-

... More
od3995/2025_2026 : Providing and fixing star white vitreous china under counter washbasin<br>of<br>approved<br>size &<br>make<br>including one CP brass pillar cock 15 mm NB with aeratorwith max flow rate of 3.8l pm or lower as per GRIHA norms <br>including<br>connectingpipes<br>with<br>all fittings 32 mm dia rubber<br>plugs 32 mm dia CP brass<br>waste coupling,32<br>mm dia CP brass<br>bottle trap,<br>15mm angle valve, etc.<br>complete as directed<br>by theEngineer-incharge<br>at all<br>levels.

35

-

-

... More
od3997/2025_2026 : Providing and fixing white vitreous china wall hung<br>washbasinof<br>approved<br>make<br>including one<br>CP<br>brass pillar cock with max flow rate of<br>3.8lpmorlower as per GRIHA norms <br>including connecting pipes<br>with all fittings 32 mm<br>dia<br>rubberplugs32 mm<br>dia CP brass waste<br>coupling ,complete including<br>CI/MS brackets<br>dulypainted,<br>nuts,washers, etc. complete,cost and<br>conveyance<br>of<br>all<br>materials<br>labourcharges ,lead,lift<br>necessary wall cutting /<br>chasingand<br>making<br>good<br>the<br>walls,floors,slab,testing andcommissioning<br>to the<br>satisfaction ofEngineer<br>in charge at<br>all levels.

5

-

-

... More
od3998/2025_2026 : Supplying and fixing CP Health Faucet with max flow rate of 3.8lpm or lower as per GRIHA norms<br>superior quality including cost of materials and labour charges etc complete as per the direction of site<br>Engineer-in-charge.

28

-

-

... More
od4000/2025_2026 : Providing and fixing white vitreous china flat back urinal<br>with<br>sensor with a<br>max flow rate of 0.6 lpf or lower as per GRIHA norms along withC.P.<br>brass spreaders with brass unions and G.I. clamps complete,<br>including<br>painting of<br>fittings<br>and<br>brackets,<br>cutting and<br>making good the walls and floors<br>wherever<br>required.

24

-

-

... More
od4001/2025_2026 : Supplying and fixing approved quality whitevitreous<br>china<br>urinal<br>division<br>plate<br>including cost and conveyance of all material, labourcharge, lead,<br>lift, etc.<br>complete as<br>directed by<br>the<br>Engineer-in-Charge.

24

-

-

... More
od4002/2025_2026 : Providing and fixing C.P. brass long body bib cock with max flow rate of 2.5lpm orlower as per GRIHA norms of approved quality conforming to IS standards and weighing not less than 690gms.

68

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

25

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

40

-

-

... More
od4005/2025_2026 : Providing and fixing floor trap with cockroach trap (multi trap), SS304 grade<br>floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer in Charge at all levels

71

-

-

... More
od4006/2025_2026 : Providing and fixing concealed floor trap with cockroach trap (multi trap), SS304 grade<br>floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete<br>as directed by the directed by the Engineer in Charge at all levels

8

-

-

... More
od4007/2025_2026 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia

6

-

-

... More
od4008/2025_2026 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame<br>with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour<br>charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm dia

17

-

-

... More
od4009/2025_2026 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin<br>one pair mounting brackets,one number pillar cock with aerator with max flow rate of 3.8l pm or lower as per<br>GRIHA norms & all other related fittings like bottle trap ,angle cock,waste coupling, etc,one number EWC &<br>Cistern with maximum flow rate of 3/6 lpf or lower as per GRIHA norms complete with fittings & seat<br>cover,one no hinged rail 76cm & 4nos. of grab rails 60cm etc designed for people with special<br>needs<br>comes with as per manufactures specification including cutting and making good the walls and<br>floors wherever required as per drawing and as directed by Engineer in charge.

2

-

-

... More
od4010/2025_2026 : Providing, fixing and testing white vitreous china extended wall mounting water closet<br>of approved shape including providing & fixing white vitreous china cistern with dual flush fitting including<br>seat cover, and cistern fittings, nuts bolts and gasket etc complete with maximum flow rate of 3/6 lpf or lower<br>as per GRIHA norms as required by the Engineer in Charge.

26

-

-

... More
od4011/2025_2026 : Providing and fixing sink cock of approved quality conforming to IS 8931 with maxflow rate of 3.8l pm or lower as per GRIHA norms.

1

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

1

-

-

... More
od4012/2025_2026 : Providing and fixing premium quality C.P. brass wall shower mixer with max flowrateof 3.8l pm or lower as per GRIHA norms along with overhead shower and shower arm withwallflanges<br>of<br>approved make<br>and model including cost of all materials, labour etc., completeasdirected by<br>the<br>Engineer-in-Charge at all<br>levels.

20

-

-

... More
od4013/2025_2026 : Providing and fixing CP robe hook etc complete testing and commissioning to the<br>satisfaction of Engineer in Charge at all levels.

26

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

20

-

-

... More
od4014/2025_2026 : Providing and fixing stainless steel soap dish including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels. <br>

20

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

55

-

-

... More
WATER SUPPLY

-

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

62

-

-

... More
od3996/2025_2026 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing thepipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed onwall<br>100 mm dia Pipes

34

-

-

... More
od3999/2025_2026 : Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete<br>with IE2 Rated motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity 20 to 7 m3/hour ,<br>Head - 12 to 36m

4

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

30

-

-

... More
od4003/2025_2026 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>75 mm nominal inner dia Pipes

33

-

-

... More
od4004/2025_2026 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall<br>65 mm nominal dia pipes

57

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

104

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

69

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

47

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

3

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

4

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

12

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

8

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

3

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

4

-

-

... More
18.31.3.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):150 mm diameterClass II

2

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

2

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

20000

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

138

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

7

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

230

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

2

-

-

... More
od4015/2025_2026 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. <50mm dia><br>

4

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

79

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

168

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

43

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

52

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

90

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

136

-

-

... More
od4016/2025_2026 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm dia

3

-

-

... More
od4017/2025_2026 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 65mm

7

-

-

... More
od4018/2025_2026 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 150mm

2

-

-

... More
od4019/2025_2026 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by the Engineer in Charge. 100mm

2

-

-

... More
od4020/2025_2026 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length<br>including cost<br>and conveyance of all materials,labour charges,making good the walls etc complete as<br>directed by<br>the Engineer in Charge. 80mm

1

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

8

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

4

-

-

... More
od4021/2025_2026 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

8

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

185

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

91

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

65

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

33

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

75

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

13

-

-

... More
od4022/2025_2026 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm 'Y' type strainer

4

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.5

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.5

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.5

-

-

... More
od4023/2025_2026 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone<br>aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

12

-

-

... More
od4024/2025_2026 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

58

-

-

... More
DG AND ACCESSORIES

-

-

-

... More
od43422/2023_2024 : Supply, Installation, Testing and Commissioning of 62.5 kVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels( CPCB IV )complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 62.5kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722.Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables,first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous ooperation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be exclusive of all the civil work including RCC foundation. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

1

-

-

... More
LT PANEL BOARDS AND ACCESSORIES

-

-

-

... More
od104049/2022_2023 METERING KIOSKbrSupply, installation, testing and commissioning of KSEB metering panel, suitablebrfor accomodating CT operated TOD meter and consisting of 3 nos. of 125 A cutout with HRC fuse,brneutral link, 125A FP MCCB isolator in separate chamber,inter connections etc. as required, andbrnecessary supports to be fabricated out of 14 SWG CRCA sheet with locable door with sealing facilitybrhaving glass window for energymeter, sealing facility for KSEB, top canopy and necessary overhang,brundergone seven tank process ,powder coated finish and all mounting accessories as required .Thebrpanel shall be with all accessories as per drawing & specification. brbr

1

-

-

... More
od104053/2022_2023 Supply, Installation, Testing & Commissioning of Factory Fabricated 415V, 50Hz, LT switch board from CPRI/ERDA approved vendors. The enclosure shall be 2 mm thick CRCA sheet which shall be free standing with floor mounting base with suitable mounting brackets with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 4. The panel shall be extensible on both ends. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker. The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for TOP/BOTTOM Cable ENTRY. Incomer 1 - 125A FP Moulded Case Circuit Breaker with Adjustable Thermal-Magnetic release (Ics =100%Icu= 25KA).- 1 nos, Incomer 2 - 100A FP Moulded Case Circuit Breaker with Adjustable Thermal-Magnetic release (Ics =100%Icu= 25KA).- 1 nos, 125A FP ATS with AMF relay-1 No, Instruments - Required HRC fuses with base for control devices, Multifunction Meters with RS485, Indication Lamps, CTs, Protection Relays as per SLD. Busbar - 125A TPN AL BUSBAR. Outgoings - 63A TP+NL, Moulded Case Circuit Breaker with Thermal based release (Ics =100%Icu= 25kA).- 4nos,40A TP+NL, Moulded Case Circuit Breaker with Thermal based release (Ics =100%Icu= 25kA).- 3,63A FP MCCB ISOLATOR-1 nos. , Surge Protection Device of Type 1+2.

1

-

-

... More
od104058/2022_2023 UPS AND ACCESSORIESbrSupply , Installation, Testing and Commissioning of 2 kVA, single phase input, single phase output, true on-line UPS system with 20 minutes back up including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet and battery mounting rack including all accessories such as cabling etc. as required complete having following specification. Fully digital controlled based on DSP Power factor corrected from end 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch.br

1

-

-

... More
od4054/2025_2026 : MSB-Supply, Installation, Testing & Commissioning of Factory Fabricated 415V, 50Hz, LT switch board from CPRI/ERDA approved vendors. The enclosure shall be 2 mm thick CRCA sheet which shall be free standing with floor mounting base with suitable mounting brackets with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specifications. as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 4. The panel shall be extensible on both ends. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker. The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with approriatly rated HRC fuses. The panel shall be suitable for TOP/BOTTOM Cable ENTRY.<br> <br>Incomer 1 - 160FP Moulded Case Circuit Breaker with Adjustable Thermal-Magnetic release (Ics =100%Icu= 25KA).- 1 nos, Incomer 2 - 100A FP Moulded Case Circuit Breaker with Adjustable Thermal-Magnetic release (Ics =100%Icu= 25KA).- 1 nos, 160A AMF relay-1 No, 160A Contactor 2 nos, 100A contactor 1 no, Bus coupler -160FP Moulded Case Circuit Breaker with Adjustable Thermal-Magnetic release (Ics =100%Icu= 25KA).- 1 nos, Instruments required for control devices, Multifunction Meters with RS485, Indication Lamps, CTs, Protection Relays as per SLD. Busbar - 160A TPN AL BUSBAR.<br>Outgoings - 63A TP+NL, Moulded Case Circuit Breaker with Thermal based release (Ics =100%Icu=25kA).- 6 nos, 40A TP+NL, Moulded Case Circuit Breaker with Thermal based release (Ics =100%Icu= 25kA).- 4, 63A FP MCCB ISOLATOR-1 nos. , Surge Protection Device of Type 1+2

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
9.1.25 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

8

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

6

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

22

-

-

... More
7.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

33

-

-

... More
7.1.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

182

-

-

... More
7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 35 sq. mm

15

-

-

... More
7.5.3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

30

-

-

... More
7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle

265

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

33

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 40x3mm MS flat clamp)

15

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

488

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

100

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 40x3mm MS flat clamp)

25

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

20

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
od104079/2022_2023 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.3.5C 120 sqmm Albr

242

-

-

... More
od104083/2022_2023 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 35 sqmm Albr

171

-

-

... More
od104085/2022_2023 Supply of 4C 16 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date

138

-

-

... More
od104086/2022_2023 Supply of 12C x 1.5 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor Controlbrcable conforming to IS 7098 (Part 1) amended upto date.

55

-

-

... More
od104089/2022_2023 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.4C 4 sqmm Cubr

248

-

-

... More
od104090/2022_2023 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.3C 4 sqmm Cubr

132

-

-

... More
od104462/2022_2023 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 part 1 amended up to date 4C 1.5 sqmm cu br

187

-

-

... More
od104464/2022_2023 Supplying and making end termination with brass compression gland and aluminium/copper lugs for 4C 1.5 sqmm Cubr of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required.br

14

-

-

... More
od104465/2022_2023 Supplying and making end termination with brass compression gland and aluminium/copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required.br3C 4sqmm Cubr

12

-

-

... More
od104482/2022_2023 Supplying and making end termination with brass compression glandbrandbraluminium/Copper lugs for following size of XLPE insulated PVCbrsheathedbr cable of 1.1 kV grade as required."br4C 4 Sq.mm 1.1 KV gradebrCu. Conductor

24

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

8

-

-

... More
7.5.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
9.1.22 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
od36538/2023_2024 Supplying and making end termination with brass compression gland and copper lugs for followingbrsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asbrrequired.2C 4 Sq.mm cu

2

-

-

... More
od36539/2023_2024 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Copperbrconductor cable conforming to IS 7098 (Part 1) amended upto date.br2C 4Sq.mm Cubr

22

-

-

... More
od36541/2023_2024 Supply of 50 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminiumbrconductors forbrworking voltages up to and including 1100 volts conforming ISbr1584/part I/1988 for PVC IS 7098 partbrI for XLPE

55

-

-

... More
9.1.7 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

6

-

-

... More
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

6

-

-

... More
od36767/2023_2024 Supply of 3C 10 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed,brarmoured aluminium conductor cable conforming to IS 7098 (Part 1)bramended upto date

35

-

-

... More
od36768/2023_2024 supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductorcable conforming to IS 7098 (Part 1) amended upto date.4C 10 sqmm Al

50

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

865

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1633

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

106

-

-

... More
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

50

-

-

... More
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

50

-

-

... More
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

50

-

-

... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

80

-

-

... More
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

1

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

1

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

2

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

29

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

177

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

2

-

-

... More
od103367/2022_2023 Supply & fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)br

4

-

-

... More
od103385/2022_2023 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inbrrecess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 ampsbrmodular switch, connection etc. as required.

10

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

304

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

5

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

10

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

10

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

148

-

-

... More
MCBs ABD DISTRIBUTION BOARDS

-

-

-

... More
od103208/2022_2023 Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredbr4 pole 40 amps. (415 Volts), 100mA sensitivity.br

2

-

-

... More
od103235/2022_2023 Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.brFour Pole

2

-

-

... More
od103236/2022_2023 Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredbr2 pole 25 amps. (240 Volts), 30mA sensitivity-br

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

169

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

18

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

2

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

6

-

-

... More
od103390/2022_2023 Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement. :Make:- Cat No Hensel-PBS 0201 or equivalent approved make)br

6

-

-

... More
od103391/2022_2023 Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thickbrsheet steel enclosure duly painted with powder coated finishing on surfacebrincluding all the mounting accessories, internal wiring etc as required complete.brbrbr

2

-

-

... More
od103392/2022_2023 Supply, Installation, Testing & Commissioning of 40A FP isolator in 1.6mm thickbrsheet steel enclosure duly painted with powder coated finishing on surfacebrincluding all the mounting accessories, internal wiring etc as required complete.brbr

1

-

-

... More
od103486/2022_2023 Supply installation, testing and commissioning of DOL starter upto 5HP,3ph motor including auxilliary contactors, 2kVAR capacitor and all necessary accessories as required complete with single phase preventor, function indiaction etc.br

6

-

-

... More
od36552/2023_2024 Supply, Installation, Testing & Commissioning of 25/32A DP MCB isolator in 1.6mmbrthick sheet steel enclosure duly painted with powder coated finishing on surfacebrincluding all the mounting accessories, internal wiring etc as required completebrwith all accessories

2

-

-

... More
od36553/2023_2024 Supply and fixing of following rating residual current circuit breaker with MCBbrhaving earth leakage and overload protection (RCCB+MCB) as per specificationas requiredbr4 pole 25amps. (415 Volts),30mA sensitivity.

5

-

-

... More
od37299/2023_2024 Supply installation, testing and commissioning of FASD starter in sheet steel enclosure for 15 HP , 3brPHASE motor including auxilliary contactors, capacitor , and all necessary accessories as requiredbrcomplete

1

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
od4077/2025_2026 : Supply and fixing of following 40-63A SP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required

6

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od103135/2022_2023 Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 100 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Philips BN100C LED40S-6500 PSU L120 GR S4 SmartBright Xtra S4 or Wipro Optima LL24-541-XXX-57-XX or Equivelent in approved make

58

-

-

... More
od103142/2022_2023 Supply of 20W Surface/Suspended Mounted LED Batten with System efficacy of more than 100 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 3 KV internal surge protection. Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Philips BN100C LED20S-6500 PSU L120 GR S4 SmartBright Xtra S4 or Wipro Optima LL24-251-XX-57-XX or equivalent in approved makes.

215

-

-

... More
od103143/2022_2023 Supply of 10 (+/-2) W High efficient LED batten surface/wall mounted, System efficacy of more than 100 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI 80, Power factor0.9, CCT - 6500K, 50000 burning hours as per L70 Criteria. Crompton TRIMLINE NEU CCS-103-10-65-SL-DP-NWH, Philips BN 021 LED12S 6500 PSU GR SMART BRIGHT or Equivelent in approved make.br

50

-

-

... More
od103152/2022_2023 "Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required.

5

-

-

... More
od103157/2022_2023 Supply of 450mm sweep heavy duty exhaust fan in die cast aluminium with metal grill/ louversbrworkingbron 230 V AC supply complete with all accessories as required

2

-

-

... More
1.41 Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

340

-

-

... More
1.49 Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

550

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

34

-

-

... More
od103180/2022_2023 Supply, Installation, Testing and Commissioning of 1200 brmm sweep, BEE 5 star rated, ceiling fan with Brush Less brDirect Current (BLDC) Motor, class of insulation: B, 3 nos. brblades, 30 cm long down rod, 2 nos. canopies, shackle kit, brsafety rope, copper winding, Power Factor not less than br0.9, Service Value (CMM/W) minimum 6.85, Air delivery brminimum 215 CMM, 350 RPM (tolerance as per IS : 374-br2019), THD less than 10%, remote or electronic regulator brunit for speed control and all remaining accessories brincluding safety pin, nut bolts, washers, temperature brrise=75 degree C (max.), insulation resistance more than br2 mega ohm, suitable for 230 V, 50 Hz, single phase AC brSupply, earthing etc. complete as required

90

-

-

... More
od104702/2022_2023 Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body with grill/ louvers workingbron 230 V AC supply complete with all accessories required

32

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

7

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
od103113/2022_2023 Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)br

37

-

-

... More
od103115/2022_2023 Providing and fixing 3.15mm Cu (10 SWG)brCu wire on surface or in recess for connections etc. as required.br

200

-

-

... More
od103118/2022_2023 Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earthbrelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.br(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

30

-

-

... More
od103119/2022_2023 Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required

10

-

-

... More
5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required

80

-

-

... More
od104731/2022_2023 Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories,and providing masonry enclosure with CI/MS cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set

5

-

-

... More
5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

100

-

-

... More
5.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing asrequired

50

-

-

... More
od4062/2025_2026 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size <br>including lamination etc. as required complete on wall. <br>

1

-

-

... More
od4064/2025_2026 : Supply and fixing of First aid box <br>

1

-

-

... More
od4065/2025_2026 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of size 2m x 1m for 3.3kV grade 2mm thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

1

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
od103129/2022_2023 "Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32brmm x 6mm and 8mm dia solid round aluminium conductor conforming to thebrrequirements according to (IS/IEC 62305) with all accessories complete asbrrequired."br

6

-

-

... More
od103130/2022_2023 Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3 br

150

-

-

... More
od103131/2022_2023 "Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal in roof with the required mounting clamps, cross connectors, expansion piece and other accessories required as per IEC 62305- 3".

180

-

-

... More
od103134/2022_2023 Supply and installation of all the materials required for maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing masonry enclosure with heavy duty CI cover plate of 300X300 mm having locking arrangement.br

6

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

150

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
od104061/2022_2023 Supply, installation, testing and commissioning of LED Street Lighting luminaire of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage of 30W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3000 and system efficiency greater than or equal to 100. The Light fitting shall be with all required accessories including single arm GI bracket of OD (30-60mm) suitable for light fixtures fixed in the wall surface.The luminaire should meet all the technical specifications as mentioned.

150

-

-

... More
od34972/2023_2024 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plantbrconforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solarbrcells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structurebrof suitable strength with following components complete as required:-bra) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming tobrIS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Modulebrconversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/brsystems must be warranted for their output peak watt capacity, which should not be less thanbr90% at the end of 10 years and 80% at the end of 25 years.brb) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, threebrphase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency notbrless than 97%, total harmonic distortion less than 3% and suitable for ambient temperature frombr0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid VoltagebrFrequency.brc) Data Monitoring System complete with accessories.brd) Fixing of Array junction box & Main junction box with IP 65 protection and terminationbrarrangement for incoming and outgoing cable along with glands, lugs and other accessories etc.bras required.bre) Lightning and surge voltage protection.brf) Connections & Interconnections by supplying & fixing required size XLPE insulated copperbrconductor 1.1 kV grade armoured power and control cables between solar modules, main powerbrcable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs andbrother accessories etc. as required.br(Cost for 1kWp as each in unit)

4

-

-

... More
FIRE HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od4145/2025_2026 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts etc. including all necessary accessories and control cabling required for successful automatic operation of pump as per technical specifications.

1

-

-

... More
od4146/2025_2026 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.

1

-

-

... More
od4147/2025_2026 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure, phosphor bronze bellows as sensing element, SPDT contact system with fittings, ball valve of suitable of suitable size etc. complete as required as per technical specification.

1

-

-

... More
od4153/2025_2026 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

92

-

-

... More
od4154/2025_2026 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS (Heavy C' Class) pipe IS:1239 marked including welding, paints, pipe supports, all fittings and accessories such as elbows, flanges, tees, reducers, neoprene gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of primer & two coats of synthetic enamel paint of suitable shade. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.

3

-

-

... More
od4155/2025_2026 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required.

1

-

-

... More
od4156/2025_2026 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body, SS disc complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.

3

-

-

... More
od4157/2025_2026 : Supply, installation, testing and commissioning of 100 mm dia Y strainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, GI bolts, GI nuts, washers etc. complete as required as per the technical specification.

1

-

-

... More
od4158/2025_2026 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification

6

-

-

... More
od4159/2025_2026 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal) dia gun metal globe valve & nozzle (c) Drum and brackets for fixing the equipment on wall (d) Connections from riser with 25 mm dia stop valve with pipe and socket

5

-

-

... More
od4160/2025_2026 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI/MS/SS wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.

12

-

-

... More
od4161/2025_2026 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification

6

-

-

... More
od4162/2025_2026 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.

6

-

-

... More
od4163/2025_2026 : Supply, installation, testing and commissioning of 2-WAY FIRE BRIGADE inlet connection made of CI Body, 100mm dia. flanged inlet with 4 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.

1

-

-

... More
od4164/2025_2026 : Supply, installation, testing and commissioning of Gun metal Air release valve, 25mm male threaded inlet, complete with all accessories as required as per the technical specification.

1

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od4139/2025_2026 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.

15

-

-

... More
od4142/2025_2026 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.

5

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
od4141/2025_2026 : Supply, installation, testing and commissioning of conventional type Manual call point of ABS type complete with all accessories like base box having provision for cable or conduit coupling as required as per technical specification.

10

-

-

... More
od4144/2025_2026 : Supply, installation, testing and commissioning of conventional type wall mountable type sounder/ hooter in MS box for fire alarm complete with all fixing accessories, base box etc. as required as per the technical specification.

10

-

-

... More
od4148/2025_2026 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W metal box speaker including all necessary accessories complete as required as per the technical specification.

15

-

-

... More
od4149/2025_2026 : Supply, installation, testing and commissioning of wall mounted talk back slave station in surface/ recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/ microphone enclosed in a MS/ ABS box with break glass in front including all necessary accessories complete as required as per the technical specification.

10

-

-

... More
od4150/2025_2026 : Supply, installation, testing and commissioning of public address and talk back system consisting of 10 zone public address cum talk back console with goose neck mike/ hand held mike, multiple channel talk back facility, power supply, battery charger, battery housing, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier, and suitable capacity battery (min 12V), etc. complete as required for meeting the technical specifications.

1

-

-

... More
od4151/2025_2026 : Supply, Installation, Testing & Commissioning of Conventional Type, 10 zone manual operated Fire Alarm Panel including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module etc.The panel shall have Keypad operation, L C D unit to indicate Fire Fault Signal of individual unit, etc complete in all respects as required as per the technical specification. The item shall also include 24 Volts sealed lead acid battery sufficient for 24 hrs back up with battery charger.

1

-

-

... More
od4152/2025_2026 : Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

1741

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

159

-

-

... More
SIGNAGES

-

-

-

... More
od4140/2025_2026 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Exit/ Fire exit/ Staircase/ Fire Staircase/ Assembly point etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

31

-

-

... More
od4143/2025_2026 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.

10

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
od4181/2025_2026 : Design, fabrication,supply of machine room less electric traction type , Stainless steel 8 Pax ( 544 Kg) passenger elevator (including freight & landing charges,insurance and all applicable taxes and duties in country of origin and in India etc except GST.) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message, LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required.The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor (IE 3 or better efficiency) of the elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre opening/Side opening SS door with stainless steel frame works, stainless steel car enclosure provided with stainless steel handrails on two sides, granite flooring as applicable in accordance of following details:--5 stops & 5 openings and entrance & exit at same side and suitable for travel height of 13.2 mtrs. (Shaft Size 2150mm (width) x 1800mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) and door opening of 800mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door .All components, fabrication and procedures of elevator system shall confirm to relevant IS standards/codes & complete in all respects as per technical specifications

1

-

-

... More
od4182/2025_2026 : Design, fabrication, supply, installation commissioning and testing of electric traction type machine room less type , Stainless steel 15 Pax(1020 Kg) Hospital elevator (including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc.except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purcahsers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction,complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device, shaft wiring and lighting with accessories,brailiy buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor (IE 3or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre opening stainless steel door with stainless steel frame work, stainless steel car enclosure provided with stainless steel handrails on two sides, granite flooring as applicable in accordance of following details:-5 stops & 5 openings and entrance & exit at same side and suitable for travel height of 13.2 mtrs. (Shaft Size 2150mm (width) x 2950mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1), door opening of 900mm (width) and 2000 mm (height) . The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications <br>

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.