Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Eprocure
Opening Date20 Aug 2019
Closing DateCancelled
Tender Amount₹ 4,09,13,300 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

1925

-

-

... More
26.27.2 : Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)

2284

-

-

... More
12.45.2 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum fire resistant board conforming to IS; 2095-Part I

683

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

5575

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

3702

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

5575

-

-

... More
od73897/2019_2020 : Supply & installation of Wooden grooved -FR grade, Salon Slats of size 128mm x 2430mm x 16mm thick Melamine finish, backlined with acoustical fleece fixed by using CC22 spaced at 600mm centers & GI channel CC18 spaced at 400mm centers with suitable brackets and the system is backlined with Synth 10x50mm thick adhered by using suitable adhesive to give NRC of 0.75. Extra wooden supports to be given to bring the panels in desired levels.

54

-

-

... More
11.54.1 : Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.300 mm Finished Floor Height (FFH).

24

-

-

... More
9.20.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

6

-

-

... More
od73901/2019_2020 : Providing Imported nylon 6 of​ approved make and colour shade 100% Optimum Solution Dyed / Wear On Nylon Tufted, Textured Loop/cut Pile Carpet tiles (Modular Carpet) of approved size and make Interface/Milliken/Shaw/. The Carpet tiles shall be Permanent static control, Pile height to a maximum of machine Gauge-1/12 Gauge, Total thickness 6mm+/-0.5mm, Density-Over ​4​500 Oz/Cu Yd, with synthetic non-woven, backing of tile as approved by client , PVC free underscore cushion including color fastness as per standard, moth proof, stain resistant, anti microbial, fire -resisting class 1 etc. complete, laying over existing flooring as per manufacturer's specification and the product shall be in compliance to ASTM standards. The quoted rate shall be all inclusive of transportation, loading, unloading etc at site and wastage etc;Warranty-15 years composite with colour, texture retention, dimensional stability and delamination. All necessary test certificate shall be enclosed with offer.Minimum Basic rate of the carpet shall be Rs.1500/sqm and the sample shall be placed before the technical sanction authority for approval. The rate shall be inclusive of surface preparation like cleaning of surface where the tiles are planned for laying and removing of loose particle and Laying of Carpet tiles including necessary pre-applied or post applied adhesives ( Note: Volatile organic compound free adhesive of approved make shall be used for laying the carpet.) for fixing over existing flooring as per Manufacturer's specification. Rate shall be inclusive of providing and laying protective plastic sheets over the laid area of carpets till the area is fully handed over and application of vacuum cleaners before handing over and also water extraction cleaning/ shampooing post occupancy for full areas.( Actual laid area only will be measured and paid.)

25

-

-

... More
od73914/2019_2020 : Modular Desk (2 Seater) : Designer legs are made of 18 guage CRCA steel,provision for taking wire from the floor to top through this leg cross & linear connectors are of 50x20 mm frame of 18 guge CRCA steel,heavy duty level adjusters,table top made of 25 mm thick prelaminated particle board,lipped with 2 mm PVC edgeband,18 mm thick prelaminated particle board modestry panel,3 nos wire manager on each table,Knock down fitting,free standing,powder coated finish for metal parts etc. Size:- 140x 60 x 75(H) cms. (Refer Technical Specifications).

600

-

-

... More
od73919/2019_2020 : Chairs : High density moulded fan for seat,Mesh on back rest,RF armscaster base made of 14 guage ERW steel tube,powder coated,bottom bush etc.

1504

-

-

... More
9.140.1 : Providing and fixing plain lining with necessary screws/nuts/& bolts/nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge ( Frame work shall be paid for separately)12 mm thick commercial ply conforming to IS: 1328 BWR type

172.5

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

1200

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

480

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1000

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

606

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

3000

-

-

... More
od77399/2019_2020 : Branding of SDPK with Acrylic Vinyl inside studio with 2x1.5m board and outside with 1x0.6m boards.

93.6

-

-

... More
od77508/2019_2020 : Modular class Room Desk (3 Seater) Designer legs are made of 18 guage CRCA steel,provision for taking wire from the floor to top through this leg cross & linear connectors are of 50x20 mm frame of 18 guge CRCA steel,heavy duty level adjusters,table top made of 25 mm thick prelaminated particle board,lipped with 2 mm PVC edgeband,18 mm thick prelaminated particle board modestry panel,3 nos wire manager on each table,Knock down fitting,free standing,powder coated finish for metal parts etc. Size:- 210x 60 x 75(H) cms. (Refer Technical Specifications)

101

-

-

... More
od77509/2019_2020 : Removal of waste using manual labour

125

-

-

... More
od77510/2019_2020 : Supply and installation of Fabric wrapped glass wool panels of size 1200x1200x25mm thick square edge installed by using prefixed Z-Bars on panel and the wall. Detail of Z- bar as per the manufacturers specification. GI cross Sectional channel of 0.45mm thk having a knurled web of 50mm width, height 25mm, having flanges of 15mm spaced at 600mm centers on the wall perpendicular to the Z-bar. GI channels are supported with wooden slats of 25mm thick 100x100mm length and width at 600mm c/c both ways. The level difference with the wooden slats to be covered with 12mm thick laminated plywood.

225

-

-

... More
od77511/2019_2020 : Supply and installation of 0.6m ht glass partition 12mm thick toughened glass fixed in to proprietary anodized aluminium sections approved make. The glass joints shall be filled with silicon sealant on both side and the vendor has to prepare the shop drawing for client / Architects approval.Rate shall include for providing transport charges, handling, loading and unloading, Installation, protecting the module and glass till handing over, testing, commissioning all necessary hardware's, scafolding,wastage, Structural supports if any, etc. complete and all as per manufacturers specifications as directed.

1.8

-

-

... More
od77512/2019_2020 : Modular Teachers Desk Designer legs are made of 18 guage CRCA steel,provision for taking wire from the floor to top through this leg cross & linear connectors are of 50x20 mm frame of 18 guge CRCA steel,heavy duty level adjusters,table top made of 25 mm thick prelaminated particle board,lipped with 2 mm PVC edgeband,18 mm thick prelaminated particle board modestry panel,3 nos wire manager on each table,Knock down fitting,free standing,powder coated finish for metal parts etc. Size:- 120x 60 x 75(H) cms. (Refer Technical Specifications)

25

-

-

... More
50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall

125

-

-

... More
50.18.7.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall

75

-

-

... More
50.18.7.4.2 : Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall

75

-

-

... More
Providing and fixing of 1mm thick laminate of approved color and shade with grooves and lines and in patterns on specified area as instructed by Architect/Client. The cost of necessary hardware's, adhesives, wastages etc; as required for complete the works. Base cost of 1mm laminate is Rs.450/1sqmt. Actual visible surfaces only will be measured and paid.

25

-

-

... More
Fixing of 12 mm thick marine plywood conforming to IS: 710 over windows, doors, celestory etc. for fixing of fabric panel.(including wastage)

400

-

-

... More
Fixing of 18 mm thick marine plywood conforming to IS: 710 over windows, celestory etc. for fixing split AC (including wastage)

100

-

-

... More
Provisional cost for loose furniture including content camera stand (80x60x90cm), Podium for speaker and low height storage with suitable partitions and door shutters with fittings with overall dimensions of 600x60x80 cm etc. in the front and back portion of studio and control room.

1

-

-

... More
Electrical works

-

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

160

-

-

... More
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

60

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

60

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

7530

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

3350

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1500

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

3000

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

300

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

250

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1900

-

-

... More
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch

25

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

150

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

3000

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

200

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

200

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

30

-

-

... More
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

30

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

76

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

52

-

-

... More
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)

425

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

520

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

26

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

624

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

300

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

104

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

26

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

2600

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

5

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

52

-

-

... More
od73853/2019_2020 : Supply installation testing and commissioning of 36 W LED recess type square light fittings (2ft) of approved make including giving connections with all accessories complete as required

508

-

-

... More
od73854/2019_2020 : Supply installation testing and commissioning of 18 W LED recess type down light fittings of approved make with all accessories complete as required

256

-

-

... More
Only Approved Make as listed in tender similar to (Wipro cat.no.LS06-005-120-WH-50 / CG CAT.NO. LST20CDL/BL/WW) non-integral flexible LED strip light.

30

-

-

... More
od73943/2019_2020 : Supply and installation of 400 mm sweep Wall Mounting fan of approved make including giving connections with all accessories complete as required

1

-

-

... More
od73856/2019_2020 : Preparation of the drawing and submission to the chief electrical inspectorate to govt.of Kerala, Kerala Electricity Board and other statutory authorities for commissioning the system including arranging inspection and also necessary approval / safety certificate from authorities etc. for the ELECTRICAL / Other services etc,. installation. The necessary statutory fees/charges will be paid by the client against demand advice.

26

-

-

... More
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

2600

-

-

... More
od73920/2019_2020 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. SITC of RJ 45 socket

52

-

-

... More
od73904/2019_2020 : Supply, fixing, testing and commissioning of the 3 kVA inverter, single phase input/ single phase output(Nominal input 230 , 50Hz(Auto detection), Input voltage range- 80-280V, Output- 230V, 65AH, 1 hour battery backup having with battery, charger, audible alarm, etc., having with the features of Micro processor based design, Automatic Line to Battery Switch over, Intelligent two stage charger, High efficient DC to AC conversion, Over Load and Short circuit protection, Auto Restart and Auto Bypass with all necessary provisions and fixing arrangements as per standard and as required at site. The rate shall also include additional DB for UPS, wirng between the sockets and inverter with flexible hose.<br>

26

-

-

... More
od73927/2019_2020 : Inverter Split AC units with a capacity of 2 TR Supply, erection, testing and commissioning of Air Cooled Split Units (Wall mounted split units ) complete with all factory wiring, piping, controls, refrigerant charge, and special features as required prior to field start-up. The units shall conform to these specifications and shall be in accordance with the requirements of Drawings and Bill of Quantities.Rate shall be inclusive of all necessary wiring between ODU & IDU, supports, other accessories etc.

101

-

-

... More
od73929/2019_2020 : Supply and providing additional copper piping(both 5/8" ,1/4") for the existing 2TR Split AC units including necessary sleevs for insulation with all accessories complete as required

120

-

-

... More
od73921/2019_2020 : Supply and providing Carbon Di Oxide Fire extinguisher-4.5 kg as required

52

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

26

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

26

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.