Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date18 May 2022
Closing Date9 Jun 2022
Tender Amount₹ 48,08,48,879 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Upgrading Kerala University Into Centre Of Excellence In Academics And Research- Infrastructure Works At Karyavattom Campus, Thiruvananthapuram

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

5

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

1

-

-

... More
EARTH WORK

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

10909.61

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

3589.55

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

11487.27

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, for all lead and lifts as per direction of site Engineer-in-charge

3464.28

-

-

... More
od178677/2021_2022 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, with all lead and lift as per direction of site Engineer-in-charge.

5037.6

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

2210.29

-

-

... More
PILING WORK

-

-

-

... More
od314921/2019_2020 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).(Note: Minimum cement content considered in M-25 is @ 400 Kg/cum as per IS 2911 : 2010 ) 500 mm dia piles

735

-

-

... More
od314924/2019_2020 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).(Note: Minimum cement content considered in M-25 is @ 400 Kg/cum as per IS 2911 : 2010 )600 mm dia piles

1958

-

-

... More
od187999/2020_2021 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Routine test (Test Load 1.5 times the Safe capacity =1.5X148 T = 222 T )

2

-

-

... More
od188000/2020_2021 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Initial test ( Test Load 2.5 times the Safe capacity=2.5X148 T=370 Tonne capacity )

1

-

-

... More
od269721/2020_2021 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Routine test (Test Load 1.5 times the Safe capacity=1.5X102=153T)

1

-

-

... More
od269722/2020_2021 : Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Initial test ( Test Load 2.5 times the Safe capacity=2.5X102=255 Tonne capacity )

1

-

-

... More
CONCRETE WORK

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

20

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

917.19

-

-

... More
4.10 : Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

466.17

-

-

... More
od35877/2022_2023 : Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.

466.17

-

-

... More
RCC WORK

-

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

175.55

-

-

... More
od316942/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting. All work upto plinth level

2174.37

-

-

... More
od316943/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting. All work above plinth level upto floor V level

3428.99

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

309.76

-

-

... More
od189840/2020_2021 : Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note :- Minimum Cement content considered in M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)

264.36

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

4335.84

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

3983.29

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

12211.69

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

14343.2

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

5975.79

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

638.91

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

4163.19

-

-

... More
5.9.16.2 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsAbove 20 cm wide

96

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

1291.56

-

-

... More
od187918/2020_2021 : Extra for Centering and shuttering for Circular Worksincluding strutting, etc. and removal of form for Lintels, beams, plinth beams, girders bressumers and cantilevers

11.25

-

-

... More
od187919/2020_2021 : Extra for circular shuttering - Centering and shuttering including strutting, etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts

145.16

-

-

... More
od187920/2020_2021 : Extra for circular shuttering - Centering and shuttering including strutting, etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide.

40.5

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

4010

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

56.88

-

-

... More
od189843/2020_2021 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting).

2.97

-

-

... More
5.13 : Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including the cost of required centering, shuttering but excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

86.82

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

285721.56

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

476068.81

-

-

... More
5.28 : Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.

433.44

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

4047.49

-

-

... More
MASONRY WORK

-

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

4043.8

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

604.97

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

86.59

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

109.25

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

37.65

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

1.02

-

-

... More
50.6.1.8 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete

2.89

-

-

... More
od313065/2019_2020 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.

28.75

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

250.27

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (Thepayment of RCC band and reinforcement shall be made for seperately).

2078.09

-

-

... More
od172867/2021_2022 : Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

372.1

-

-

... More
JOINERY WORK

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

5972.41

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

5022.01

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

68.06

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

23.93

-

-

... More
od260053/2021_2022 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With high performance glass panes of 6 mm thickness meeting GRIHA compliance of overall value VLT - 34%, SHGC - 0.34.

1265.03

-

-

... More
od312124/2019_2020 : Providing and fixing steel (white power coated) crescent lock for uPVC /aluminum sliding window/ door with necessary screws etc. complete.

1168

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

2

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

12.37

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters

137.28

-

-

... More
9.5.1.2 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Providing and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood30 mm thick shutters

6

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

131.52

-

-

... More
9.7.7.2 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:5.5mm thick glass pane

6

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

4.39

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

157.68

-

-

... More
9.20.3 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard ) including ISI marked nickel plated bright finished M.S. piano hinges IS : 3818 marked with necessary screws

296.73

-

-

... More
9.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

486.06

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1752

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

234

-

-

... More
9.79.4 : Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.75 mm

336

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

300

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

302

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

257

-

-

... More
9.92.1 : Providing and fixing chromium plated brass handles with necessary screws etc. complete:125 mm

70

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

383

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

475

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

2

-

-

... More
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.

2

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

27

-

-

... More
50.9.1.2 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood

1.18

-

-

... More
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop

6

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

1242.68

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

34.8

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

330.97

-

-

... More
9.125 : Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.

16.8

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

5

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

232.8

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

46.73

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

27.44

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

28.8

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

9

-

-

... More
od188043/2020_2021 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.

4

-

-

... More
FLOORING

-

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

35.38

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

625.15

-

-

... More
8.5 : Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

62

-

-

... More
8.9.1.2 : Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of any colour and shade

134.04

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.

2742.22

-

-

... More
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete

342.46

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

42.09

-

-

... More
11.20.3 : Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement

307.56

-

-

... More
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick

310.75

-

-

... More
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

110.78

-

-

... More
11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.

3.6

-

-

... More
od316940/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.

905.62

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

8704.62

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

769.82

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

240.56

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

550.46

-

-

... More
STEEL WORK

-

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

8920.88

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

200

-

-

... More
10.19 : Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.

500

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

3252.1

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

20771.6

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

3470.4

-

-

... More
10.27.2 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm

1080

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

8155.94

-

-

... More
CEILING WORK

-

-

-

... More
12.45.1 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1

415.35

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

117.7

-

-

... More
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

2879.32

-

-

... More
ROOFING WORK

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

323.72

-

-

... More
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.

181.61

-

-

... More
FINISHING WORK

-

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

2253.31

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

45668.73

-

-

... More
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)

4036

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

13127.06

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

8893.65

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

84

-

-

... More
13.27 : Extra for lining out plaster to imitate stone or concrete blocks walling.

2283.55

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

256.8

-

-

... More
od313071/2019_2020 : 15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

810.73

-

-

... More
13.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer'sspecification.

274.63

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

45199.16

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

606.92

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

297

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

4957.71

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

5284.7

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

63.36

-

-

... More
13.50.4 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)

1098.4

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

44587.95

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

2326.96

-

-

... More
13.114 : Melamine polishing on wood work (one or more coat).

1337.38

-

-

... More
DISMANTLING WORK

-

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

19.4

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

32.26

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

1

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

29.83

-

-

... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

18.32

-

-

... More
PAVER WORK

-

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

5042.25

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

146.42

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

1147.09

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

1399.2

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.

1563

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

27

-

-

... More
WATER PROOFING WORK

-

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

715.75

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

2140.07

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.

1083.97

-

-

... More
22.24A : Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be appliedas intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5mm thickness after scrapping and properly cleaning the surface to remove looseparticles from the plaster surface, followed by top coating with Premium AcrylicSmooth exterior paint with Silicone additives of required shade by two or morecoats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge

485.59

-

-

... More
MISCELLANEOUS WORK

-

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

12000

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

76

-

-

... More
19.15.2 : Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) as per standard design.With 20 mm diameter round bar

72

-

-

... More
21.7.1 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Anodised aluminium sheet 2.5 mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

135

-

-

... More
21.7.2 : Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fastners of 8 mm dia and 75 mm long bolt including providing aluminium - washers 2 mm thick 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per drawing and direction of Engineer -in-charge.Powder coated aluminium sheet 2.5 mm thick ( minimum thickness of powder coating 50 micron)

84

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

514.28

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

2.85

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

2.85

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

2.85

-

-

... More
30.2.57.1 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

85

-

-

... More
od172714/2021_2022 : Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25cm as per direction of the officer-in-charge.

5

-

-

... More
od172715/2021_2022 : Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
od172716/2021_2022 : Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

5

-

-

... More
od172717/2021_2022 : Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.

5

-

-

... More
od172718/2021_2022 : Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge.

8

-

-

... More
od172719/2021_2022 : Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.

8

-

-

... More
od172720/2021_2022 : Providing and stacking of Peltophorum species of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

12

-

-

... More
od172721/2021_2022 : Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

8

-

-

... More
od172722/2021_2022 : Providing and stacking of Michelia champa (Golden Champa) of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

9

-

-

... More
od172723/2021_2022 : Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.

11

-

-

... More
od172786/2021_2022 : Providing and stacking of Tectona grandis (Teak) of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

3

-

-

... More
od172787/2021_2022 : Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge.

3

-

-

... More
od172788/2021_2022 : Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.

3

-

-

... More
od189340/2020_2021 : Providing weep holes in Brick/Rubble masonry/Plain/Reinforced concrete abutment, wing wall/return wall with PVC pipe 75 mm outer dia 6kgf/cm2, extending through the full width of the structure with slope of 1V : 20H towards drawing face.Complete as per drawing and Technical Specifications

405

-

-

... More
od189841/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

22

-

-

... More
od189845/2020_2021 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

9

-

-

... More
od189874/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

2

-

-

... More
od189977/2020_2021 : Providing and constructing soak pit 1.5 m x 1.5 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

2

-

-

... More
od190005/2020_2021 : Supplying, Drilling/Cleaning hole and injecting epoxy resin based ETA Approved HIT-RE 500 V3 chemical/ equivalent with the help of manual dispenser, into a hole of dia depth (belowmentioned) as per manufacturer/structural consultant specification and fixing rebars ofthe required diameter subsequently. The chemical should have successfull usage inwet/water saturated concrete/diamond cored holes. The chemical should have approvalagainst creep corrosion, ICC, CSTB, COLA, BZS Shock approved, Seismic C1/C2approved to use in cracked/un-cracked concrete, tested for service temperature of -40deg C to +70 deg C and LEED certified injection adhesive for rebar fixing in wet/DRY conditions for diameter up to 40mm, also the chemical should have 100 years service lifetest. Fixing methodology to be followed as per manufacturers guidelines. - Steel will bepaid under separate subhead. Manufacture to submit Rebar Depth Calculation based ondesign loads other parameters as provided by consulatnt and in accordance with EOTATR-023/029 guidelines for post installed rebar connections for approval.All complete as per the direction of engineer in charge :-2. Fixing 20mm rebar at 483mm embedment depth

112

-

-

... More
od190006/2020_2021 : Supplying, Drilling/Cleaning hole and injecting epoxy resin based ETA Approved HIT-RE 500 V3 chemical/ equivalent with the help of manual dispenser, into a hole of dia depth (belowmentioned) as per manufacturer/structural consultant specification and fixing rebars ofthe required diameter subsequently. The chemical should have successfull usage inwet/water saturated concrete/diamond cored holes. The chemical should have approvalagainst creep corrosion, ICC, CSTB, COLA, BZS Shock approved, Seismic C1/C2approved to use in cracked/un-cracked concrete, tested for service temperature of -40deg C to +70 deg C and LEED certified injection adhesive for rebar fixing in wet/dryconditions for diameter up to 40mm, also the chemical should have 100 years service lifetest. Fixing methodology to be followed as per manufacturers guidelines. - Steel will bepaid under separate subhead. Manufacture to submit Rebar Depth Calculation based ondesign loads other parameters as provided by consulatnt and in accordance with EOTATR-023/029 guidelines for post installed rebar connections for approval.All complete as per the direction of engineer in charge:- 1.Fixing 16mm rebar at 386mm embedment depth

42

-

-

... More
od312119/2019_2020 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge.600x600mm

2

-

-

... More
Sanitary works

-

-

-

... More
od180033/2021_2022 : :Providing and fixing white vitreous china extended wall mounting water closet of approved shape and size including providing ; fixing white vitreous china cistern with dual flush,fitting, of flushing capacity 2 litre/4 litres , including seat cover,angle valve and cistern fittings,nuts bolts and gasket etc complete as directed by the engineer in charge at all levels. Models CeraS1031111+B1020105+B1520102/ Hindware 20096 (P-15)+Cist.: 21056 or equivalent with griha water conservation mechanism etc complete as directed by the Engineer in charge at all levels.

70

-

-

... More
od184693/2021_2022 : Providing and fixing floor trap 110 mm dia (gratings concealed)with cockroach trap (multi trap), S304 grade concealed floor grating with multitrap including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

12

-

-

... More
od187251/2020_2021 : Providing and fixing premium quality C.P. brass wall shower mixer with provision for overhead shower with bend pipe of approved make and model including cost of all materials, labour etc.complete as directed by the Engineer-in-Charge at all levels confirming to GRIHA complying flow rates.(Models: Cera catalogue no:F1015401 or equivalent)

2

-

-

... More
od316303/2019_2020 : Providing and fixing premium quality C.P. brass overhead shower and wall flange of approved make and model including cost of all materials, labour etc., complete as directed by the Engineer in-in-Charge at all levels.(Cera F7020304+F7040104+F1015201 or Hindware F160039+F200008 or equivalent with griha water conservation mechanism)

65

-

-

... More
od187254/2020_2021 : Providing and fixing water heater of approved MOC, quality, make of storage capacity 25 litres of approved quality and make including cost and conveyance of all materials labour charges ,lead, lift,cutting and making good the walls,slabs,floors wherever required as per direction of Engineer-In-charge at all levels.(models:Jaquar catalogue no:Elena or equivalent)

2

-

-

... More
od189101/2020_2021 : Providing and fixing star white vitreous china under counter wash basin of approved size & make including one CP brass pillar cock 15 mm NB with aerator including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling,32mm dia CP brass bottle trap,15mm angle valve, etc.complete as directed by the Engineer in charge at all levels.(Models CeraS2030103/ Hindware 1004900SW+ Cera F1015101/Hindware F280001CP or equivalent with griha complying flow rates)

75

-

-

... More
od189102/2020_2021 : Providing and fixing white vitreous china flat back urinal with sensor andC.Pbrass spreaders with brass unions and G.I. clamps complete, including painting of fittings,brackets,cutting and making good the walls and floors wherever required: ModelsHindware 6002110 /Cera S4010101or equivalent with griha complying flow rates

42

-

-

... More
od189103/2020_2021 : Supplying and fixing approved quality white vitreous china urinal division plate including cost and conveyance of all material, labour charge, lead, lift, etc.complete as directed by the Engineer-in-Charge. Models- Cera S4090101/ Hindware 61001 or equivalent

44

-

-

... More
od189109/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm dia

34

-

-

... More
od189110/2020_2021 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Framewith Flat Round Cover with Rubber Seal; SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm dia

42

-

-

... More
od189113/2020_2021 : Providing and fixing floor trap with cockroach trap (multi trap), SS304 grade floor grating with cup including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

187

-

-

... More
od189114/2020_2021 : Providing and fixing sanitary fixtures for handicapped toilet including one wash basin& one number pillar cock with aerator & all other related fittings like CP brass bottle trap,CP brass angle valve, CP brass waste coupling, etc, one number EWC ; Cistern complete with fittings, seat cover,one no. hinged rail ; 4 nos. of grab rails 60cm etc, designed for people with special needs comes with as per manufacturers specification including cutting and making good the walls and floors wherever required as directed by Engineer-in-Charge. Hindware Matrix Set/Cera Cruse Set, Hindware F280001CP/Cera F1015101 or equivalent.

7

-

-

... More
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

2

-

-

... More
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps

2

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

2

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

6

-

-

... More
od316242/2019_2020 : Providing and fixing sink cock of approved quality conforming to IS 8931. Models CeraF1015251/Hindware F330034 or equivalent with griha water conservation mechanism as approved by the Engineer in charge at all levels

8

-

-

... More
od180305/2021_2022 : Providing and fixing C.P. brass long body bib cock with griha complying flow rates , of approved quality conforming to IS standards and weighing not less than 690 gms. Models ;Hindware F400002CP/ Jaquar FLR-CHR-5047NGE or equivalent 15 mm nominal bore

143

-

-

... More
17.22A : Providing and fixing CP Brass 32mm size Bottle trap of approved quality & make and as per the direction of Engineer in charge.

2

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

81

-

-

... More
18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore

2

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

77

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

127

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

65

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

65

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

80

-

-

... More
od269758/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kgf/cm2 - Internal work- Exposed on wall

153

-

-

... More
od269760/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling ; testing of joints complete as per direction of Engineer in Charge. 160 mm dia 6 Kgf/cm2

1125

-

-

... More
od269761/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling ; testing of joints complete as per direction of Engineer in Charge. 110 mm dia 6 Kgf/cm2

429

-

-

... More
od269762/2020_2021 : Providing and fixing PVC pipes including jointing of pipes,fittings and specials with one step PVC solvent cement, trenching, refilling ; testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/cm2

72

-

-

... More
od269764/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

60

-

-

... More
od269765/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

249

-

-

... More
od269766/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

75

-

-

... More
od269767/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall

695

-

-

... More
od269768/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 kgf/cm2

361

-

-

... More
od269769/2020_2021 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes,fittings ; specials with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110mm pipe 6 kgf/cm2

243

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

15

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

5

-

-

... More
19.30.2.1 : Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

9

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

1.5

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

1.5

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

31

-

-

... More
od189117/2020_2021 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone ;aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

52

-

-

... More
od189118/2020_2021 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

20

-

-

... More
od187715/2020_2021 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 150 mm dia 6 Kgf/cm2 - External work- Exposed on wall

21

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

21

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

35

-

-

... More
Water supply

-

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

282

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

237

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 32 mm nominal outer dia pipes

261

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

336

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

306

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

3

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

3

-

-

... More
18.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipes

398

-

-

... More
18.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipes

884

-

-

... More
18.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipes

12

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

26

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

26

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

29

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

38

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

33

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

15

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

13

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

18

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

8

-

-

... More
18.31.1.2 : Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):100 mm diameterClass II

17

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

33000

-

-

... More
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

1

-

-

... More
18.61.1 : Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :80 mm dia

1

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1.5

-

-

... More
50.18.8.1.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2

24

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

308

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

726

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

955

-

-

... More
50.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2

60

-

-

... More
od316431/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall ;80 mm nominal dia pipes

33

-

-

... More
od316298/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall ;65 mm nominal dia pipes

138

-

-

... More
od189107/2020_2021 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot ; cold water supply, including all CPVC plain ; brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall ;100mm nominal dia

69

-

-

... More
od189134/2020_2021 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge. ;600x600mm

12

-

-

... More
od189141/2020_2021 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: ;300 mm dia R.C.C. pipe

60

-

-

... More
od189142/2020_2021 : Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: ;150 mm dia R.C.C. pipe

60

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

10

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

90

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

10

-

-

... More
od316248/2019_2020 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-charge

17

-

-

... More
od316251/2019_2020 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 ;mm dia

12

-

-

... More
od316252/2019_2020 : Supplying and fixing ball valve with all accessories including cost and conveyance ;of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. ;40 mm dia

6

-

-

... More
od316253/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance ;of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. ;50 mm dia

18

-

-

... More
od316254/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 65mm

15

-

-

... More
od316255/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 80mm

15

-

-

... More
od316256/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 80mm

12

-

-

... More
od316257/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 150mm

9

-

-

... More
od316258/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 100mm

18

-

-

... More
od316259/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 100mm

15

-

-

... More
od316260/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as ;directed by the Engineer in Charge. 150mm

15

-

-

... More
od316261/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mm

4

-

-

... More
od316262/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mm

15

-

-

... More
od316263/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length ;including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mm

6

-

-

... More
od316264/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm ;Y type strainer

14

-

-

... More
od316265/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 40mm ;Y type strainer

10

-

-

... More
od269759/2020_2021 : Supplying and fixing GI threaded rod for fixing pipes to walls on slotted channels adequately spaced from the walls.The rate is inclusive of cost and conveyance of all materials,labour charges etc and as directed by the Engineer in charge at all levels.

329

-

-

... More
od316270/2019_2020 : od37131/2018_2019 :Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 10 m3/hr Head: 26 m

4

-

-

... More
od316333/2019_2020 : od37131/2018_2019 :Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 15 to 6 m3/hr Head: 24 to 36 m

4

-

-

... More
od316467/2019_2020 : od37131/2018_2019 :Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels ;Capacity: 27 to 9 m3/hr Head:27 to 15m

4

-

-

... More
od316329/2019_2020 : Providing and fixing enclosed type water meter (bulk type) 65mm dia conforming to IS :2373 and tested by Municipal Board complete with bolts, nuts, rubber etc. (The tail pieces if required will be paid separately) including cost and conveyance of all materials, labouRretc. complete and as directed by Engineer-in-Charge.

2

-

-

... More
od316330/2019_2020 : Providing and fixing CI Y type strainer 65mm dia rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials, labour etc. complete and as directed by Engineer-in-Charge

2

-

-

... More
od317354/2019_2020 : Providing and fixing PVC pipes includings jointing of pipes and fittings with one step pvc solvent cement, trenching , refilling ; testing of joints complete as per direction of Engineer in Charge. 200 mm dia 6 Kgf/cm2

90

-

-

... More
HVAC EQUIPMENT

-

-

-

... More
od180134/2021_2022 : Supply, installation, testing and commissioning of the 46 HP minimum capacity of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil seperator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off, ODU vibration isolators with necessary structural supports, , suitable for 3 phase, 415 V, 50Hz supply, All associated electrical works including power control panel, power control cabling between isolator and single/multiple outdoor units along with all associated accessories complete in all respects as per technical specification.

2

-

-

... More
od180137/2021_2022 : Supply, installation, testing and commissioning of the 40 HP minimum capacity of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil seperator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off, ODU vibration isolators with necessary structural supports, , suitable for 3 phase, 415 V, 50Hz supply, All associated electrical works including power control panel, power control cabling between isolator and single/multiple outdoor units along with all associated accessories complete in all respects as per technical specification.

1

-

-

... More
od180139/2021_2022 : Supply, installation, testing and commissioning of the 26 HP minimum capacity of Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with multiple compressors, with variable speed inverter driven compressor as per specifications complete with suitable capacity drive motors, air cooled condenser, R410A/R407C refrigerant, oil seperator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off, ODU vibration isolators with necessary structural supports, , suitable for 3 phase, 415 V, 50Hz supply, All associated electrical works including power control panel, power control cabling between isolator and single/multiple outdoor units along with all associated accessories complete in all respects as per technical specification.

1

-

-

... More
od180141/2021_2022 : Supply, Installation , testing and commissioning of 18TR minimum capacity Double skin,sheet metal AIR-HANDLING UNIT for VRF System with required AHU kit as per technical specifications complete with outlet volume control dampers, canvas connections, filter section containing washable synthetic type air filters having extruded aluminum frame having filtration capacity of 10 micron particle size with an efficiency of 90%, cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerent gas of R410A/407C, IDU SS drain pan,squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor),thermostat wiring, required starter and starter panel , structural supports for fixing IDU, safety devices etc. complete in all respects as required by the technical specifications to meet adequate external static pressure for the following minimum capacity and the cooling coil (min 4 rows), suitable for three phase 440V supply etc. (Minimum External Static Pressure 50 mmwc )

4

-

-

... More
od180143/2021_2022 : Supply,Installation , testing and commissioning of 11TR minimum capacity VRF compatible ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display,complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth covering including U-trap along with necessary elbows, fittings power control cabling from power supply, etc complete in all respects as per the technical specifications. (Minimum External Static Pressure 25 mmwc )

2

-

-

... More
od180144/2021_2022 : Supply,Installation , testing and commissioning of 8 TR minimum capacity VRF compatible ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display,complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth covering including U-trap along with necessary elbows, fittings power control cabling from power supply, etc complete in all respects as per the technical specifications. (Minimum External Static Pressure 25 mmwc )

3

-

-

... More
od180145/2021_2022 : Supply,Installation , testing and commissioning of 4 TR minimum capacityVRFcompatible ceiling suspended indoor ductable units with all standard fittings, outlet volume control dampers, flexible connectors, IDU SS drain pan, as per specifications complete with cordless remotes, power wiring, suitable capacity drive motor, electrical controller, temperature controller with digital display,complete with necessary vibration isolators, CPVC drain pipe connections with 9mm thick round nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth covering including U-trap along with necessary elbows, fittings power control cabling from power supply, etc complete in all respects as per the technical specifications. (Minimum External Static Pressure 25 mmwc )

1

-

-

... More
od180147/2021_2022 : Supply,Installation ,testing commissioning of VRF compatible 2 TR (minimum capacity) Hi wall Split air conditioning unit complete with suitable capacity drive motor, control cabling(indoor to outdoor),thermostat wiring,drain piping, cordless remote,. suitable for single phase 230 V supply and with suitable stabilizer etc complete in all respects as per technical specifications

1

-

-

... More
od180772/2021_2022 : Supply, installation, testing and commissioning (SITC) of the 11 TR Minimum capacity air-cooled Ductable split air conditioner (IDU ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 10 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,CPVC condensate drain pipe upto 5m 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with factory laminated glass cloth as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported on trays, clamps, vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

2

-

-

... More
od180773/2021_2022 : Supply, installation, testing and commissioning (SITC) of the 8.5TR Minimum capacity air-cooled Ductable split air conditioner (IDU ODU) with ceiling suspended IDU and all standard fittings, outlet volume control dampers, canvas connections, IDU SS drain pan, as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, electronic microprocessor pendant controller with digital display, first charge refrigerant gas, suitable sized copper refrigerant piping(both suction and liquid piping) as per relevant ASHRAE standards upto 10 mtr including 19mm thick closed cell Class O elastomeric insulation finished with 7mils factory laminated glass cloth suitably supported on trays/ split clamps etc. ,CPVC condensate drain pipe upto 5m 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell elastomeric insulation finished with factory laminated glass cloth as per specification required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, suitably supported on trays, clamps, vibration isolator pads, structural supports for fixing IDU/ ODU as per drawings/standards, safety devices including thermal protector, pressure relief valve, over load relays, single phase preventer, high-low pressure cut off etc., power wiring(max 3m from isolator) and control cabling(indoor to outdoor),thermostat wiring etc. suitable for three phase 440V etc. complete in all respects as per technical specifications.

1

-

-

... More
od180774/2021_2022 : Supply, installation, testing and commissioning of CPVC drain pipe (beyond 5 m) of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with 7 mils factory laminated glass cloth as per specification required pipe fittings and accessories like bends, tees, reducers, supports, clamps, suitably supported with clamps etc. complete in all respects as per the technical specifications.

30

-

-

... More
od180559/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/4") 44.45 mm

10

-

-

... More
od180268/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 5/8") 41.275 mm

60

-

-

... More
od180560/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 3/8") 34.925

30

-

-

... More
od180244/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/4") 31.75 mm

10

-

-

... More
od180280/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1 1/8") 28.575 mm

96

-

-

... More
od180290/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 7/8") 22.225 mm

12

-

-

... More
od180299/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/4") 19.05 mm

84

-

-

... More
od180322/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 5/8") 15.875 mm

66

-

-

... More
od180405/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 1/2") 12.7 mm

42

-

-

... More
od180412/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Hard Copper Pipe 18Guage with 19mm thick Insulation ( 3/8") 9.525 mm

24

-

-

... More
od180416/2021_2022 : Supply,Installation ,testing and commissioning of Gas/ Liquid Copper Piping with nitrile rubber insulation finished with factory laminated 7 mils treated fibre glass cloth, suction filters for gas line, filter drier sight glass for liquid line as per specification for each indoor machines outdoor units including chasing,drilling,concealing and making good the same on walls etc of following specifications as per site conditions and with required pipe fittings and accessories like Bends, Tees, reducers, supports, clamps, refnets etc.Complete in all respects as per technical specifications.Soft Copper Pipe 18Guage with 19mm thick Insulation ( 1/4") 6.35 mm

5

-

-

... More
od180427/2021_2022 : Supply, installation testing and commissioning of the DX inverter type 1.5 TR minimum capacity Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 3 star rated as per BEE and with suitable stabilizer with necessary supports vibration isolators suitable as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation as per specification interconnecting indoor outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports finished with 7 mils factory laminated treated fibre glass cloth, necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, finished with 7 mils factory laminated treated fibre glass cloth, first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per technical specification

2

-

-

... More
od180468/2021_2022 : Supply Installation, testing and commissioning of central controller above specified system and associated accessories etc complete in all respects as per the technical specifications.

1

-

-

... More
od180529/2021_2022 : Supply, installation, testing and commissioning of CPVC drain pipe (beyond 5 m) of suitable dia connecting the drain pan of the indoor units with necessary U-traps, elbows, fittings etc. to nearest drain point, with insulated with 9 mm thick closed cell elastomeric class 0 insulation with 7 mils factory laminated glass cloth as per specification required pipe fittings and accessories like bends, tees, reducers, supports, clamps, suitably supported with clamps etc. complete in all respects as per the technical specifications.

150

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

778

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1046

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

60

-

-

... More
od180547/2021_2022 : Supplying and fixing of 19 mm thick 55kg/m3 density, regular closed cell class 0 nitrile rubber insulation finished with 7 mils factory laminated glass cloth ,anti-microbial protection. Butt all joints tightly and seal all breaks and joints by adhering glass cloth tape,(on duct ) etc. complete in all respects as required by the technical specifications

1835

-

-

... More
od180548/2021_2022 : Supply , Installation testing and commissioning of Acoustic lining inside sheet metal ducts with 10mm thick Open Cell nitrile rubber class 1,having density 140-180 kg/m3 insulation using manufacturers recommended complete in all respects as required by the technical specifications.

483

-

-

... More
od180549/2021_2022 : Supply fixing of Acoustic Insulation of AHU Rooms using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 25 mm with suitable frame works etc. complete in all respects as required by the technical specifications

271

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

23

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

23

-

-

... More
od180552/2021_2022 : Supply, Installation , testing and commissioning of Aluminium Extruded Fresh air louvers with fresh air damper, bird screen etc. complete in all respects as per the technical specifications.

4

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

16

-

-

... More
od180553/2021_2022 : Supply, Installation ,testing commissioning of Fusible link type Fire damper of 16 gauge GI sheets with fire rating of 300 Deg C for 2 hr for air distribution Networks, complete in all respects as per the technical specifications.

13

-

-

... More
HYDRANT AND SPRINKLER SYSTEM

-

-

-

... More
od317557/2019_2020 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller, SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation. M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. as required. The cost shall include suitable capacity DOL starter and one isolator near the pump complete with all necessary control cabling and power cabling from starter to pump, complete as required as per the technical specification to provide successful automatic operation of the pump.

2

-

-

... More
od189422/2020_2021 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 450lpm, 40 m head C.I body, bronze impeller, SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation. M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. as required. The cost shall include suitable capacity DOL starter and one isolator near the pump complete with all necessary control cabling and power cabling from starter to pump, complete as required as per the technical specification to provide successful automatic operation of the pump.

2

-

-

... More
od317558/2019_2020 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, suitable ball valve for isolation etc. complete as required as per technical specification.

4

-

-

... More
od317559/2019_2020 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 -14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals and ball valve for isolation including fittings, etc. complete as required as per the technical specification.

4

-

-

... More
od317525/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 25 mm dia

658

-

-

... More
od317526/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 32 mm dia

102

-

-

... More
od317528/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 40 mm dia

154

-

-

... More
od317530/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 50mm dia

21

-

-

... More
od317531/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 65 mm dia

80

-

-

... More
od317534/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 80 mm dia

262

-

-

... More
od317535/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 100 mm dia

643

-

-

... More
od317539/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification. 100 mm dia

73

-

-

... More
od317540/2019_2020 : Supply, laying, testing commissioning of 'C' class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification. 80 mm dia

6

-

-

... More
od317542/2019_2020 : Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 pressure rating complete with CI body, SS plates, rubber gasket, GI bolts, nuts, washers etc. as required as per technical specification and confirming to API:594. 100 mm dia

8

-

-

... More
od317543/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM/ Nitrile rubber liner,SS disc, O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 40 mm dia

7

-

-

... More
od317545/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, SS Disc, EPDM/ Nitrile Rubber lining, O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 80 mm dia

1

-

-

... More
od317546/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM/ Nitrile rubber liner,SS disc, O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 100 mm dia

29

-

-

... More
od317547/2019_2020 : Supply, Installation, testing and commissioning of 100 mm dia Y strainer with CI body, 3 mm perforated SS screen, flanged end connection confirming to IS specifications complete with gaskets, seal and accssesories as required as per the technical specification.

4

-

-

... More
od317549/2019_2020 : Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc required as per the technical specification.

36

-

-

... More
od317563/2019_2020 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585 (b) 20 mm (nominal internal ) dia gun metal globe valve nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) pipe

32

-

-

... More
od317564/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per technical specification

72

-

-

... More
od317561/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required.

36

-

-

... More
od317552/2019_2020 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.

36

-

-

... More
od317565/2019_2020 : Supply, installation, testing and commissioning of 2-WAY FIRE BRIGADE inlet connections made of CI Body, 100mm dia. flanged inlet with 2-Nos. of inbuilt Gunmetal NRV (Body type) with PVC Blank cap Chain complete as required as per technical specification

4

-

-

... More
od317553/2019_2020 : Supply, installation, testing and commissioning of Air release valve 25 mm dia. complete as required as per the technical specification.

12

-

-

... More
od317554/2019_2020 : Supply, installation, testing and commissioning of Standard response, standard coverage sprinkler, upright type sprinkler ;1/2" NPT, K -5.6 ; operating temperature at 68 deg. C. complete as required as per the technical specification.

219

-

-

... More
PORTABLE FIRE EXTINGUISHERS

-

-

-

... More
od317515/2019_2020 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark. complete as required as per the technical specification.

50

-

-

... More
od317517/2019_2020 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification.

10

-

-

... More
od317518/2019_2020 : Supply and installation of ISI marked Clean agent type fire extinguisher of 2kg capacity. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket, all the accessories and as per the technical specifications.

1

-

-

... More
FIRE ALARM SYSTEM

-

-

-

... More
od317527/2019_2020 : Supply and laying of 2x 1.5sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above ground, on walls and ceilings etc. complete as required as per the technical specification.

1518

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

66

-

-

... More
od317529/2019_2020 : Supply, Installation, Testing Commissioning of Conventional Type, 4 zone Fire Alarm Panel including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module etc. The panel shall have Keypad operation, LCD unit to indicate Fire /Fault Signal of individual unit, etc complete in all respects as required as per the technical specification. The item shall also include 24 Volts sealed lead acid battery sufficient for 24 hrs back up with battery charger.

1

-

-

... More
od317532/2019_2020 : Providing, installing, testing and commissioning of conventional type Hooter with a minimum sound level of 80DB at 10 Ft Distance,interconnecting to loop cable complete as required as per the technical specification.

11

-

-

... More
od317533/2019_2020 : Supply installation Testing and commissioning of Conventional type Manual Call Point Resettable type via Special Key Interconnecting to loop cable as required as per the technical specification.

11

-

-

... More
od317536/2019_2020 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication for fire fighters including all necessary accessories complete as required as per the technical specification.

11

-

-

... More
od317537/2019_2020 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.

11

-

-

... More
od317538/2019_2020 : Supply, installation, testing and commissioning of public address and talk back system consisting of 12 zone public address cum talkback console with mike and selector,multiple channel talk back master control panel with LCD display,power supply, battery charger, battery housing, suitable watt PA mic, multiple channel selector with all call and mic on. The console shall be provided with suitable capacity amplifier (min 100W) and suitable capacity battery (min 12V) all assembled in a cabinet and meeting the technical specifications. The rate shall include the cost of all the necessary accessories as required for the operation of the system. This shall be having facility for seamless integration with main fire alarm panel for voice evacuation complete as required.

1

-

-

... More
SIGNAGES

-

-

-

... More
od317516/2019_2020 : Supply and installation of glow signage (photoluminescent) such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

72

-

-

... More
od317986/2019_2020 : Supply and installation of glow signage (photoluminescent)of FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

4

-

-

... More
od317519/2019_2020 : Supply and installation of glow signage (photoluminescent) of FIRE ORDER of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

28

-

-

... More
od317520/2019_2020 : Supply and installation of glow signage (photoluminescent) such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel. The signage will be either fixed on the wall with the help of screws double tape or hanged from the false ceiling with the help of chain screws etc. complete as required as per the technical specification.

54

-

-

... More
od317521/2019_2020 : Supply and installation of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwiched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification.

28

-

-

... More
ELEVATOR SYSTEM

-

-

-

... More
GIRLS DORMITORY od180783/2021_2022 : Design, fabrication, supply,installation ,testing and commissioning of electric traction machine roomless type , Stainless steel 10 Pax (680 Kg) passenger elevator (including freight landing charges,insurance and all applicable taxes and duties in country of origin and in India etc. except gst) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message, LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required..The traction motor of elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door with stainless steel frame works, stainless steel car enclosure provided with stainless steel handrails on two sides, granite flooring as applicable in accordance of following details:- 3 stops 3 openings and entrance exit at same side and suitable for travel height of 6.6 mtrs. (Shaft Size 2150mm (width) x 1900mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) and door opening of 800mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door .All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

1

-

-

... More
BOYS DORMITORY od180782/2021_2022 : Design, fabrication, supply.Installation ,testing and commissioning of electric traction machine roomless type , Stainless steel 10 Pax (680 Kg) passenger elevator (including freight landing charges,insurance and all applicable taxes and duties in country of origin and in India etc., except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message, LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required..The traction motor of elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door with stainless steel frame works, stainless steel car enclosure provided with stainless steel handrails on two sides, granite flooring as applicable in accordance of following details:-2 stops 2 openings and entrance exit at same side and suitable for travel height of 3.3 mtrs. (Shaft Size 2150mm (width) x 1900mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) and door opening of 800mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door .All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

1

-

-

... More
SICC od180784/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction machine roomless type , Stainless steel 10 Pax (680 Kg) passenger elevator (including freight landing charges,insurance and all applicable taxes and duties in country of origin and in India etc. except gst) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, duplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message,LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The traction motor of machine room elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic centre/side opening SS door with stainless steel frame works, stainless steel car enclosure provided with stainless steel handrails on two sides, granite flooring as applicable in accordance of following details:-2 stops 2 openings and entrance exit at same side and suitable for travel height of 4.2 mtrs. (Shaft Size 2150mm (width) x 2100mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) and door opening of 800mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door .All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

2

-

-

... More
R&D CENTRE od180785/2021_2022 : Design, fabrication, supply, installation, testing, commissioning of electric traction machine roomless type , Stainless steel 26 Pax (1768Kg) Hospital elevator (including freight landing charges,insurance and all applicable taxes and duties in country of origin and in India etc., except gst) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchasers's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman’s switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories,braille buttons,audio announcement along with prerecorded message, LED light fixtures, ventilation fan, etc complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The traction motor of elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification. Having automatic Side opening stainless steel doors, stainless steel car enclosure provided with stainless steel handrails on three sides, granite flooring as applicable in accordance of following details:-4 stops 4 openings and entrance exit at same side and suitable for travel height of 11.8 mtrs. (Shaft Size 2400mm (width) x 3300mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1) and door opening of 1200mm (width) and 2000 mm (height) . The equipment should be BMS compatible.All electrical components with wiring from the single point power supply provided in last landing near the elevator door .All fabrication and procedures shall confirm to relevant IS standards and complete in all respects as per technical specifications

1

-

-

... More
STRUCTURED CABLING COMPONENTS FOR DATA, VOICE AND CCTV

-

-

-

... More
od192142/2021_2022 : Supply, Installation, Testing and Commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per technical specification

5020

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

3343

-

-

... More
od192150/2021_2022 : Supply, Installation, Testing and Commissioning of concealed Metal Back Box with all accessories required at site complete as per technical specification

68

-

-

... More
od192158/2021_2022 : Supply, Installation, Testing and Commissioning of Category 6 information Outlet, RJ 45 with all accessories required at site including termination complete as per technical specification

83

-

-

... More
od192161/2021_2022 : Supply, Installation, Testing and Commissioning of Category 6 24 port patch panel, fully loaded with I/Os, including termination as required at site complete as per technical specification

5

-

-

... More
od192162/2021_2022 : Supply, Installation, Testing and Commissioning of Single or Dual Shuttered Face Plate with all accessories required at site complete as per technical specification

69

-

-

... More
od192164/2021_2022 : Supply, Installation, Testing and Commissioning of Category 6 - 1m Patch Cord with end termination and all accessories required at site complete as per technical specification

73

-

-

... More
od192168/2021_2022 : Supply, Installation, Testing and Commissioning of PVC cable channel 45mm x 45mm as required at site as per technical specification.

13

-

-

... More
od192172/2021_2022 : Supply, Installation, Testing and Commissioning of 27U Floor mount Network Rack, size - 600 x 800mm, along with all necessary hardware and accessories required at site complete as per technical specification.

1

-

-

... More
od38636/2022_2023 : Supply, Installation, Testing and Commissioning of 6U Wall mount Network Rack, Single section, along with all necessary hardware and accessories required at site complete as per technical specification

1

-

-

... More
IP SURVEILLANCE

-

-

-

... More
od192140/2021_2022 : Supply, Installation, Testing and Commissioning of 2MP varifocal motorised IP camera, PoE, IP66 rated with all accessories required at site complete as per technical specification

13

-

-

... More
od192147/2021_2022 : Supply, Installation, Testing and Commissioning of 32 channel Network Video Recorder, RAID 5, SAS/Enterprise HDDs for 30 days archiving, with all hardware, software, cabling and other accessories required at site complete as per technical specification. The Contractor shall submit storage calculation for video recording at 15 frame/second in minimum HD resolution

1

-

-

... More
od194189/2021_2022 : Supply, Installation, Testing and Commissioning of 55" commercial display, 24/7 with HDMI and USB ports with all accessories required at site complete as per technical specification

1

-

-

... More
SURGE PROTECTION SYSTEM

-

-

-

... More
od192137/2021_2022 : Supply, Installation, Testing and Commissioning of Surge protection device including proper earthing and all accessories required at site complete as per technical specification

1

-

-

... More
ACTIVE DEVICES

-

-

-

... More
od192141/2021_2022 : Supply, Installation, Testing and Commissioning of 24 port switch - Layer 2, 24 x 10/100/1000Base-TX ports including all necessary hardware, software and accessories required at site complete as per technical specification

3

-

-

... More
od192149/2021_2022 : Supply, Installation, Testing and Commissioning of 24 port PoE+ switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports including all necessary hardware, software and accessories as required at site complete as per technical specification

1

-

-

... More
od192151/2021_2022 : Supply, Installation, Testing and Commissioning of 24 port Layer 3 Core switch with minimum 20 x 10G Ethernet ports and 2 x 10G SFP+ ports including all necessary hardware, software and accessories as required at site complete as per technical specification

1

-

-

... More
od192155/2021_2022 : Supply, Installation, Testing and Commissioning of Firewall for 75 concurrent users including hardware, software, licenses, security subscriptions, cabling and other accessories required at site complete as per technical specification.

1

-

-

... More
HT EQUIPMENTS AND DG SET

-

-

-

... More
od40670/2020_2021 : Supply, Installation, Testing and Commissioning of 62.5 kVA prime rated D.G Set with acoustic enclosure and Control panel including reverse power relay ,protection and digital metering,controls and interlocks, CTs (including supply an fixing of neutral CT) and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 62.5 kVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.

2

-

-

... More
od268569/2020_2021 : UNITIZED SUBSTATION- 315kVA Design, fabrication, Supply, installation, testing and commissioning of outdoor type Unitized Substation including foundation for 315 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 54 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, etc. complete as per single line diagram technical specification. HT Chamber 630A 26.2kA 11kV LBS with earth switch Transformer Compartment 315kVA, 11kV/433V 3 Ph, 50Hz, Dry type, vector Dyn -11 Transformer, copper wound, Class F insulation, outdoor distribution Transformer. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. "The transformer shall also have suitable enclosure including supply and fixing of suitable rating neutral CT of burden 10VA and class 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: 500A FP thermal based MCCB and S=suitable for terminating 2 R x300 sq.mm cable."

1

-

-

... More
od42242/2020_2021 : 315 KVA DRY TYPE INDOOR TRANSFORMER Design, fabrication, Supply, installation, testing and commissioning of indoor type TRANSFORMER 315 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP 23 enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift etc. complete as per single line diagram technical specification. 315 KVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer. Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 10% to -10% in steps of 2.5%. "The transformer shall also have suitable enclosure including supply and fixing of neutral CT of suitable rating , 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: Suitable for terminating 2 RUN 3.5C x 300 sq.mm cable."

1

-

-

... More
od42244/2020_2021 : RMU-CCVVV Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos motorized Load break switch as incomer and 3 nos motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators ,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type and compatible for SCADA system. The rate quoted shall be inclusive of required mounting accessories, hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram technical specification.

1

-

-

... More
od188613/2020_2021 : VCB PANEL VCB panel rated at 11kV,800A 25kA( for 3 seconds), Electrically operated draw out type both side extendable (fully encapsulated vacuum interrupter) fabricated out of 14 guage Powder Coated CRCA/AluZinc in Shade RAL 7032 . The panel shall be with 800A Aluminium busbar support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control, motor operated spring charged mechanism, anti-pumping device, 24V DC shunt trip, and closing coil, control wiring, power pack etc and having following specific components and as per IS / IEC standards. The quote shall be inclusive of hoisting the panel to respective location, assembling of panels, lining up bolting the units, checking all the control wiring. Calibration and all instruments as per state Electrical Inspectorate standards. The panel comprises of 800A, 11kV,25 kA (3 sec), VCB, Electricaly operated drawout type, with 3 Nos single phase PT 11kV/√3/110 V /√3,50VA(minimum), indication lamps, analogue and digital meters with communication port, numerical protection relays with communication port,50/51 realys (overcurrent and earthfault) required number of CTs for metering and protection, annunciation window, emergency push button, electrical inter locks etc. as detailed in SLD- 1 No. Cable Earthing Truck suitable for VCB - 1 No The panel shall be with bottom / top entry to receive incoming outgoing cable, all necessary interconnection accessories as per particular specification single line diagram.

1

-

-

... More
od42243/2020_2021 : 365 KVA DIESEL GENERATOR "Supply, Installation, Testing and Commissioning of 365 KVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs (including supply an fixing of neutral CT) and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe (with stack) conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 365 KVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery."

1

-

-

... More
LT PANEL BOARDS

-

-

-

... More
od40674/2020_2021 : SSB-Ladies Dormitory Supply, installation, testing and commissioning of LT Switch Board cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, wall / floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4A Construction. Instruments RYB Indicating lamps LED type -As per SLD 4A SP MCB-6 Nos (0-500)V Class 1 with 90 deg defl. Scale-As per SLD (0-160)A Class 1 with 90 deg defl. Scale -As per SLD (0-100)A Class 1 with 90 deg defl. Scale -As per SLD Voltmeter selector switch -As per SLD Ammeter selector switch -As per SLD 160/5 A 5 VA Class 1 CTs -As per SLD 1005 A 5 VA Class 1 CTs -As per SLD ON/OFF/TRIP INDICATION LAMP -As per SLD Digital multifunction meter to read V,A.Hz,PF,Kwh- As per SLD surge protection device (type 1+2)-As per SLD Incomer 160A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 Nos 100A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 Nos 160A ATS with AMF Relay 160A TPN busbar chamber with Aluminium busbar< Out goings 63A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link and shunt trip (Ics =100%Icu= 25kA) -7Nos 40A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link and shunt trip (Ics =100%Icu= 25kA) -1No 40A TP+NL MCCB ISOLATOR-1 No The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification

1

-

-

... More
od40675/2020_2021 : MSB- Residential Supply , Installation, Testing Commissioning of LT Switch board cubicle type compartmentalised (form 4A), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. Incomer 630A , 50kA FP Moulded Case Circuit Breaker with Microprocessor based release -1 no Busbar 630A 50kA TPN busbar chamber with Aluminium busbar "Pluggable type surge arrester Type 1 - 1 set " Instruments 4A MCB - 3 Nos. RYB indication lamp, LED type - 1set (0-500)V voltmeter, Acc. class 1 with 90 deg defl. Scale with Voltmeter selection switch - 1Nos. (0-630)A ammeter Acc. class 1 with 90 deg defl. scale - 3Nos. 630/5A 15VA class 1 resin cast CT -1set 630/5A 15VA class 1 resin cast CT for IPFC Relay -1set Digital Multi function meter with Acc Cl1 with RS485 communication -1no. Outgoings 160A , 50kA TP+NL Moulded Case Circuit Breaker with Microprocessor based release and neutral link -3 nos 320A , 50kA TP+NL Moulded Case Circuit Breaker with Microprocessor based release and neutral link -1nos 400A , 50kA TP+NL Moulded Case Circuit Breaker with Microprocessor based release and neutral link -2nos

1

-

-

... More
od40676/2020_2021 : APFC PANEL 120 KVAR SITC of LT Switch Board (120VAR APFC), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 3b Construction. Incomer 320A , 36kA FP Moulded Case Circuit Breaker with thermal based release -1 no Instruments RYB Indicating lamps LED type -3 Nos. (0-500)V Class 1 with 90 deg defl. Scale-1 Nos (0-320)A Class 1 with 90 deg defl. Scale-3 Nos Voltmeter selector switch - 1 No 320/5 A 5 VA Class 1 CTs -3 Nos Digitalmultimeter to read V,A.Hz,PF,kWH -1 No. Microprocessor based intelligent, 12 step IPFC relay with PF display and necessary accessories- 1 No. Auto / manual selector switch - 1 no. ON-OFF -TRIP indication lamp - 1 set. Busbar 400A TPN busbar chamber with Aluminium busbar. Outgoing 125A, 25kA, TP MCCB with adjustable thermal magnetic release with OL SC protection - 1no. 63A, 25kA, TP MCCB with adjustable thermal magnetic release with OL SC protection - 3nos. 25A, 25kA, TP MCCB with adjustable thermal magnetic release with OL SC protection - 5 nos. 50 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1 No. 20 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2Nos. 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 No. 5kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 Nos. 50 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor -1 No 20 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 2Nos 10 kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor -2 Nos 5kVAr,480 V,50 Hz heavy duty capacitor(MPP-H) with 7 % Series reactor - 2Nos Control wiring required for no load compensation capacitor The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per SLD and technical specification

2

-

-

... More
od186256/2020_2021 : SSB- Equipment Supply, Installation, testing and Commissioning of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4 Construction. Instruments RYB Indicating lamps LED type -3 Nos. (0-500)V Class 1 with 90 deg defl. Scale-1 Nos (0-200)A Class 1 with 90 deg defl. Scale-3 Nos Voltmeter selector switch - 1 No 200/5 A 5 VA Class 1 CTs -3 Nos Digitalmultimeter to read V,A.Hz,PF,kWH -1 No. Incomer 200A FP , 35kA Moulded Case Circuit Breaker with thermal release and neutral link .- 1no 200A TPN busbar chamber with Aluminium busbar. Out goings 63A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 4nos. 40A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 2nos. The panel shall be Top/Bottom Entry/Exit and suitable for termination of cable/Bus system as per SLD and technical specification

1

-

-

... More
od38167/2020_2021 : SB- Gents Dormitory Supply, installation, testing and commissioning of LT Switch Board (Main Panel), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, wall / floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4 Construction. Instruments RYB Indicating lamps LED type -As per SLD 4A SP MCB-6 Nos (0-500)V Class 1 with 90 deg defl. Scale-As per SLD (0-160)A Class 1 with 90 deg defl. Scale -As per SLD (0-100)A Class 1 with 90 deg defl. Scale -As per SLD Voltmeter selector switch -As per SLD Ammeter selector switch -As per SLD 160/5 A 5 VA Class 1 CTs -As per SLD 100/5 A 5 VA Class 1 CTs -As per SLD ON/OFF/TRIP INDICATION LAMP -As per SLD Digital multifunction meter to read V,A.Hz,PF,Kwh- As per SLD surge protection device (type1+2)-As per SLD Incomer 160A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 Nos 100A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 Nos 160A FP ATS with AMF Relay 160A TPN busbar chamber with Aluminium busbar Out goings 63A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link and shunt trip (Ics =100%Icu= 25kA) -7Nos 40A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link and shunt trip (Ics =100%Icu= 25kA) -1No 40A TP MCCB ISOLATOR-1 No The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specification

1

-

-

... More
od42245/2020_2021 : SB -2 Supply , Installation, Testing Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. Incomer 400A , 36kA FP Moulded Case Circuit Breaker with Microprocessor based release -1 no Busbar 400A TPN busbar chamber with Aluminium busbar Instruments SPD Type 2, 4A SP MCB - As per SLD RYB indication lamp, LED type - As per SLD (0-500)V voltmeter, Acc. class 1 with 90 deg defl. Scale with Voltmeter selection switch - As per SLD (0-400)A ammeter Acc. class 1 with 90 deg defl. scale - As per SLD 400/5A 15VA class 1 resin cast CT - As per SLD Digital Multi function meter with Acc Cl1 with RS485 communication - As per SLD Outgoings 200A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -2 Nos 200A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -2Nos 125A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -3Nos 100A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -2Nos 63A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -1Nos

1

-

-

... More
od42246/2020_2021 : SSB-1- UTILITY PANEL Supply , Installation, Testing Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. Incomer 125A , 25kA FP Moulded Case Circuit Breaker with thermal based release -1 no Busbar 125A TPN busbar chamber with Aluminium busbar Instruments 4A SP MCB - As per SLD RYB indication lamp, LED type - As per SLD (0-500)V voltmeter, Acc. class 1 with 90 deg defl. Scale with Voltmeter selection switch - As per SLD (0-125)A ammeter Acc. class 1 with 90 deg defl. scale - As per SLD 125/5A 15VA class 1 resin cast CT -1set Digital Multi function meter with Acc Cl1 with RS485 communication - As per SLD, Outgoings 63 25kA TP+NL Moulded Case Circuit Breaker with thermal release -5 Nos 40 A FP MCCB isolator- 1No

1

-

-

... More
od42248/2020_2021 : SB-1 -HVAC Supply , Installation, Testing Commissioning of LT Switch board cubicle type compartmentalised (form 4A), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. Incomer 320A , 36kA FP Moulded Case Circuit Breaker with Thermal based release -1 no Busbar 320A TPN busbar chamber with Aluminium busbar Instruments SPD- type 2 4A MCB - As per SLD RYB indication lamp, LED type - As per SLD (0-500)V voltmeter, Acc. class 1 with 90 deg defl. Scale with Voltmeter selection switch - As per SLD (0-320)A ammeter Acc. class 1 with 90 deg defl. scale -As per SLD 320/5A 15VA class 1 resin cast CT -1set Digital Multi function meter with Acc Cl1 with RS485 communication -As per SLD, Outgoings 100A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -4 Nos 63A 36kA TP+NL Moulded Case Circuit Breaker with thermal release -5 Nos

1

-

-

... More
od42249/2020_2021 : MSB Supply , Installation, Testing Commissioning of LT Switch board cubicle type compartmentalised (form 4), made out of 2mm thick CRCA sheet, totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars extendable on both sides, including all the necessay internal wiring , with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. Incomer 630A , 50kA FP Moulded Case Circuit Breaker with Microprocessor based release -2 no Busbar 630A TPN busbar chamber with Aluminium busbar 630A FP ATS with AMF relay -1no Instruments Incomer 4A, C curve SP MCB - As per SLD ON OFF TRIP Indicator- As per SLD RYB indication lamp, LED type - As per SLD Digital Multi function meter with Acc Cl1 with RS485 communication -2no. (0 to 500 )V Voltmeter for 3 phase, 4 wire operation with selector switch - As per SLD (0-600) A ammeter for 3 phase, 4 wire operation - As per SLD 600/5A 15VA class 1 resin cast CT - As per SLD 600/5A 15VA class 1 resin cast CT for IPFC Relay - As per SLD Low set earth fault relay- 1 set SPD Type 1 as per IEC 61643 - 1 set . Outgoings 400A , 50kA TP+NL Moulded Case Circuit Breaker with Microprocessor based release and neutral link -2 Nos 320A, 50kA TP+NL Moulded Case Circuit Breaker with Microprocessor based release and neutral link -3 Nos Instruments Outgoing ON OFF -As per SLD The main panel shall have space provision to incorporate CO2 flooding system ( Fire protection) as per NBC 2016. Bus bar shall be extendable type. The panel shall be with Top/bottom entry to receive incoming outgoing cable, all necessary interconnection accessories as per technical specification single line diagram.

1

-

-

... More
CABLES AND CABLING

-

-

-

... More
od40678/2020_2021 : Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm

74

-

-

... More
od40679/2020_2021 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300sq.mm.

1890

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

1681

-

-

... More
8.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm

125

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

63

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

80

-

-

... More
10.2.4 : Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

2

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

10

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

20

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

34

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

52

-

-

... More
od40734/2020_2021 : Supplying and making end termination with brass compression gland and copper lugs for 2C 4 sqmm PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

38

-

-

... More
od40735/2020_2021 : Supplying and making end termination with brass compression gland and copper lugs for 4C 1.5 sqmm PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

36

-

-

... More
od40736/2020_2021 : Supplying and making end termination with brass compression gland and copper lugs for 4C 4 sqmm PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

120

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

4

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

520

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

142

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

588

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

617

-

-

... More
7.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

15

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

157

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

235

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

27

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

32

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

30

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

15

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

20

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1087

-

-

... More
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

116

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

106

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

3114

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

484

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

243

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

360

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

110

-

-

... More
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia

160

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

140

-

-

... More
od40861/2020_2021 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 150 MM WIDTH X 50 MM DEPTH X 2 MM THICK

200

-

-

... More
od40862/2020_2021 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 300 MM WIDTH X 50 MM DEPTH X 2 MM THICK

500

-

-

... More
od40863/2020_2021 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 600 MM WIDTH X 50 MM DEPTH X 2 MM THICK

350

-

-

... More
od40865/2020_2021 : Providing fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

2.5

-

-

... More
od40866/2020_2021 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

1550

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

50

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

30

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

8

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

10

-

-

... More
od179646/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 4 Sq.mm cU

180

-

-

... More
od179647/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3c 10 Sq.mm Al

42

-

-

... More
od179648/2021_2022 : Supply of 3.5C 300 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

284

-

-

... More
od179649/2021_2022 : Supply of 4C 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminiumconductor cable conforming to IS 7098 (Part 1) amended upto date.

505

-

-

... More
od179650/2021_2022 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

1135

-

-

... More
od179651/2021_2022 : Supply of 3.5C 50 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

210

-

-

... More
od179652/2021_2022 : Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured FRLS Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 sq.mm Al

405

-

-

... More
od179653/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 4 Cu

2269

-

-

... More
od179655/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS Copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 1.5 Cu

378

-

-

... More
od179656/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 240 Sq mm

704

-

-

... More
od179770/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 4 Sq.mm cU

756

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

170

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

170

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

4

-

-

... More
od185723/2021_2022 : Supplying and making end termination with brass doublr compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C 4 Sq mm Cu

36

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

94

-

-

... More
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm

21

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

33

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

138

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

8

-

-

... More
od186464/2020_2021 : Supplying and making end termination with brass compression gland and COPPER lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2C 6 sqmm Cu

16

-

-

... More
od182132/2021_2022 : Supply of following size 1.1 KV grade FRLS XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 6 Sq.mm cU

331

-

-

... More
od182138/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 185 Sq mm

231

-

-

... More
7.2.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

16

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

10

-

-

... More
10.3.4 : Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

2

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

18

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

6

-

-

... More
od184358/2021_2022 : Supply of 3.5C 120 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

21

-

-

... More
od184359/2021_2022 : Supply of 3.5C 70 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.

557

-

-

... More
od184368/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured FRLS Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 400 Sqmm.

137

-

-

... More
od184371/2021_2022 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 4C 10 Sq.mm Cu

24

-

-

... More
od184372/2021_2022 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, unarmoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 Sq.mm Cu Unarmored

120

-

-

... More
od185203/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessery accessories as required 450 MM WIDTH X 50MM DEPTH X 2 MM THICK

100

-

-

... More
UPS AND ACCESSORIES

-

-

-

... More
od40874/2020_2021 : Supply , Installation, Testing and Commissioning of 1 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation

2

-

-

... More
od39720/2020_2021 : Supply, Installation, Testing and Commissioning of 30 kVA, three phase input, Three Phase output, true on-line UPS system with 30 minutes back up , inbuilt output isolation transformer and IGBT rectifier, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories, cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit and one set of battery bank . RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch

3

-

-

... More
od42251/2020_2021 : Supply, Installation, Testing and Commissioning of 20 kVA, three phase input, Three Phase output, true on-line UPS system with 30 minutes back up , inbuilt output isolation transformer and IGBT rectifier, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories, cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit and one set of battery bank . RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch

1

-

-

... More
od187098/2020_2021 : Supply, Installation, Testing and Commissioning of 10 kVA, three phase input, Three Phase output, true on-line UPS System with 30 minutes back up , output isolation transformer, voltage stabilizerincluding all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories cabling etc as required complete having following specification. RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Regulated output voltage frequency. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Back up time 30 minutes at full load

2

-

-

... More
od187099/2020_2021 : Supply, Installation, Testing and Commissioning of 15 kVA, three phase input, Three Phase output, true on-line UPS system with 15 minutes back up , output isolation transformer and IGBT rectifier, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories, cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit and one set of battery bank . RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch

3

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

8025

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

3290

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

14830

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

9270

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

545

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

9

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

9

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

13

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

6

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

8

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

35

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

39

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

400

-

-

... More
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

8

-

-

... More
od40919/2020_2021 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.

58

-

-

... More
od40920/2020_2021 : Supply fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)

68

-

-

... More
od179508/2021_2022 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

125

-

-

... More
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

545

-

-

... More
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm

15800

-

-

... More
od180539/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B

171

-

-

... More
od180540/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A

165

-

-

... More
od180541/2021_2022 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

303

-

-

... More
od180542/2021_2022 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

43

-

-

... More
od180543/2021_2022 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in existing PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

938

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

13

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

35

-

-

... More
od39775/2020_2021 : Supply and laying of UPVC cable management system of size 80mmx50mm including all accessories such as plastic trunking 80mmx 50mm, flexible cover, base joint, end cap, flat angles, flat junctions, external angles etc as required complete.

350

-

-

... More
od187226/2020_2021 : supplying and Laying of UPVC cable management system of size 105mmx50mm along with all accessories such as flexible cover, base joint, end cap, flat angles, flat junctions, external angles etc as required complete.

40

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

20

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
od40922/2020_2021 : Supply, Installation, Testing Commissioning of 40A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

14

-

-

... More
od40923/2020_2021 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A TP MCB, C-CURVE

44

-

-

... More
od40924/2020_2021 : Supply and fixing of following rating, 10 KA, Miniature Circuit Breakers as required. 40-63A FP MCB, C-CURVE

5

-

-

... More
od40925/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25amps. (230 Volts),30mA sensitivity.

2

-

-

... More
od40926/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 25amps. (415 Volts),30mA sensitivity.

10

-

-

... More
od40928/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 63 amps. (415 Volts),100mA sensitivity.

10

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

6

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

421

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

87

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

80

-

-

... More
od41263/2020_2021 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement. :Make:- Cat No Hensel-PBS 0201 or equivalent approved make)

21

-

-

... More
od188107/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25 amps. (240 Volts), 100mA sensitivity-

2

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

13

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

7

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

6

-

-

... More
90.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor

18

-

-

... More
90.14.28.6 : S & F Motor starters of the following ratingsFully automatic star delta starter for 15HP motor

3

-

-

... More
od180945/2021_2022 : Supply, Installation, Testing Commissioning of 40A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

4

-

-

... More
od39780/2020_2021 : Supplying and fixing 32amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 32 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

7

-

-

... More
od39784/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 40 amps. (415 Volts),100mA sensitivity.

7

-

-

... More
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
od39835/2020_2021 : Supply, Installation, Testing Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.

20

-

-

... More
od187190/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 160Amp,25KA,FPMCCB

2

-

-

... More
od187192/2020_2021 : Supply and fixing of following rating, 10 KA, Miniature circuit breakers of the following series as required. 6A to 32A ,TP D curve MCB

10

-

-

... More
od187194/2020_2021 : Supply and fixing of following rating, 10 KA, Miniature circuit breakers of the following series as required. 6A to 32A ,SP D curve MCB

94

-

-

... More
2.2.15 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required200 Amp, 36 KA

1

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

9

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

8

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

2

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
od186580/2021_2022 : Providing and fixing following 100Amp rating and 25 KA breaking capacity and four pole MCCB in existing distribution board, making connections, etc. as required.

4

-

-

... More
od186581/2021_2022 : Providing and fixing following 125Amp rating and 25 KA breaking capacity and four pole MCCB in existing distribution board, making connections, etc. as required.

1

-

-

... More
od186582/2021_2022 : Supplying and fixing 6 amps to 32 amps Triple pole rating, 415 volts, "D" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.

12

-

-

... More
od186583/2021_2022 : Supplying and fixing 40 amps to 63 amps Triple pole rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
od186585/2021_2022 : Supply and fixing of following 4 pole 40amps. (415 Volts),30mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

2

-

-

... More
od186587/2021_2022 : Supply and fixing of following 4 pole 25amps. (415 Volts),100mA sensitivity rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required

8

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

3

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od41271/2020_2021 : Supply of IP66 LED Street Lighting luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 30W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 with system lumens greater than 3000 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required accessories suitable for mounting on the pole arm.The luminaire should have Inbuilt surge protection of4KV (L-N ,L-E N-E)and should be equipped with external surge protection device (SPD) to withstand 5KV5AMake:- Cat No: Wipro LR02-331-XXX-57-XX or equivalent approved make

38

-

-

... More
od41272/2020_2021 : Supply of IP66 LED Floodlight luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 60W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 with system lumens greater than 6000 and system efficiency greater than or equal to 100%.Make:- Cat No: Wipro LF19-711-060-57-G2 or or equivalent approved make

22

-

-

... More
od41274/2020_2021 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,system wattage of maximum 18Watts,lumen output of luminaire greater than 2000, power factor >0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved make

742

-

-

... More
od41275/2020_2021 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser ,along with driver,system wattage of maximum 10 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 25,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved make

129

-

-

... More
od41277/2020_2021 : Installation, testing and commissioning of High bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cable as required.

57

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

964

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

1641

-

-

... More
od41291/2020_2021 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)

193

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

78

-

-

... More
od180974/2021_2022 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,with a maximum system wattage of 40 Watts,lumen output of luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24

60

-

-

... More
od180975/2021_2022 : Supply of 10w LED Bulk head fitting with die cast aluminium housing, PC diffuser and IP65 Protection suitable for wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required.(make: Wipro LW07 or equivalent wipro make)

30

-

-

... More
od180976/2021_2022 : Supply of 380 mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton EXHD-380-6-1 or equivalant approved make)

6

-

-

... More
od180977/2021_2022 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Crompton Brisk Air or equivalant approved make)

72

-

-

... More
od39837/2020_2021 : Supply of LED recess mounted down light made of die cast aluminium, along with driver,system wattage of maximum 18Watts,lumen output of luminaire greater than 1600 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 90umen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro:Helios 231 LED or equivalent approved makes

113

-

-

... More
od39844/2020_2021 : Installation, testing and commissioning of LED PANEL fittings with chain and copper wiring with all accessories, lamps etc. on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.

257

-

-

... More
od39845/2020_2021 : Installation, testing and commissioning of Wall fan, including wiring the down rods of standard length with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

3

-

-

... More
od39846/2020_2021 : Installation, testing and commissioning of LED down lighter fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor as required.

154

-

-

... More
od188196/2020_2021 : Supply of LED recess mounted down light made of die cast aluminium, along with driver,surge protection, maximum system wattage of 9 Watts, with lumen output of luminaire greater than or equal to 900 lumens, power factor >= 0.95,THDi <10%, rated life of L70 @ 50,000 hours, system efficacy greater than or equal to 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Wipro Helios or equivalent approved makes)

41

-

-

... More
od183607/2021_2022 : Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.

3

-

-

... More
od183610/2021_2022 : Supply of recess mounted LED panel light fixture light made of CRCA along with driver,system wattage of maximum 36 Watts with lumen output of fixture not less than 3600 lumens, power factor > 0.95, THD<10%,rated life of L70 @ 50,000hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete.Make:-WIPROCRCO10R038HP57GL1 or equivalent approved make

296

-

-

... More
od187745/2021_2022 : Supply of surface mounted LED panel light fixture light made of CRCA Sheet with corrosion resistance p[owder coating, along with driver, max system wattage of 36 Watts with lumen output of lamp not less than 3600 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than 100 lumen/watt and including all necessary accessories as required complete(Make:Wipro Elate LED 36W Surface 2x2 CRCO10S038HP57GL1 or equivalent approved make)

5

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
od41382/2020_2021 : Earthing with C.I. earth pipe 3 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)

40

-

-

... More
od41389/2020_2021 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

5

-

-

... More
od41390/2020_2021 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

9

-

-

... More
od41391/2020_2021 : Supply of Rubber hand gloves suitable for 11 kV.

6

-

-

... More
od41392/2020_2021 : Supply of First aid box

7

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

8

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
od181810/2021_2022 : Supply and fixing anodised aluminum glass framed shock treatment chart

7

-

-

... More
od181811/2021_2022 : Providing and fixing 3.15mm Cu (10 SWG) Cu wire on surface or in recess for connections etc. as required.

3690

-

-

... More
od181812/2021_2022 : Providing and fixing 8 swg GI wire GI wire on surface or in recess for connections etc. as required.

61

-

-

... More
od181813/2021_2022 : Supplying and laying 8 swg GI wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm)

1293

-

-

... More
od181814/2021_2022 : Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt spring washer spaced at 50mm)

594

-

-

... More
od181815/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

2

-

-

... More
od181816/2021_2022 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

5

-

-

... More
od181817/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.50x10 GI

370

-

-

... More
od181818/2021_2022 : Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required.25x3mm Cu strip

771

-

-

... More
od181819/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm) 50x10mm Gi strip

420

-

-

... More
od181820/2021_2022 : Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. 25x3mm Cu

345

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

1721

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

778

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

20

-

-

... More
od183600/2021_2022 : Supply and installation of maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing Heavy duty enclosure cover plate as required complete.

22

-

-

... More
5.11 : Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

42

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
od182275/2021_2022 : Supply, erecting, installing testing and commissioning of 6 meter octogonal street light pole and all in one LED solar street light fixture. The pole made out of hot dip galvanised 3 mm thick MS sheet, primered and octagonal pole with single arm bracket . The pole should have a flush door at bottom with inbuilt control box, proper cutout and provision for mounting DP MCB,four pole connector for easy loop-in loop-out,concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture. The pole shall be installed on existing civil foundation with foundation bolt. All in one integrated LED solar streetlight consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection having a system wattage of 40 with 60Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12V, >23.4 Ah Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be at least 150lm/W and LED driver should have >90% efficiency. Typical correlated colour temperature should be 5700K with CRI>70.The luminaire should be housed in IK 08 impact resistance certified aluminum with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution.

56

-

-

... More
od43135/2020_2021 : Supply ,Installation,Testing commissioning of Bollard light CCT 3000K) in range of 0.9m-1m height, Luminaire made of aluminium. Protection class IP 65.Suitable for operation on 240V, 50Hz single phase ac supply with system Wattage 16+/-3W and Warm White fixture Make :KLITE VIRGIO 7046 equivalent approved make

10

-

-

... More
LIGHTNING PROTECTION

-

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

390

-

-

... More
od183603/2021_2022 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

680

-

-

... More
od183604/2021_2022 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3

342

-

-

... More
od183605/2021_2022 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor conforming to the requirements according to (IS/IEC 62305) with all accessories complete as required.

22

-

-

... More
SOLAR WORKS

-

-

-

... More
od182409/2021_2022 : "Supply, Installation, Testing and Commissioning of Grid Tied solar string inverter of 6kVA rating , IP 66 rated, outdoor, three Phase output, true sinewave inverter system, with Maximum Power Point Tracker charge controller. Inverter should have MPPT with 1 string per MPPT. Minimum protection required shall be over voltage/surge, over load, short circuit and anti- islanding protection. Earthing shall be provided as per IEC standards. IGBT based true sine wave output. Unity Power factor(6kVA=6kW) . Accuracy of AC voltage control = +/-3%. Accuracy of AC frequency control = +/-1%. Frequency = 50Hz. Intelligent interface with LED/LCD display(Bluetooth/Wifi interface is also acceptable) . .Total Harmonic Distortion <3%”. The inverter should have all specification, protections, operational modes, etc as detailed in techinical specification. The inverter should have in-built Type Surge protection device on AC and DC side.The item includes all necessary accessories like supports, canopy, AC Isolation boxes(with energy meter), Junction boxes, Combiner boxes, DCDBs, cabling from AC Isolation boxes to inverter, connectors, etc as required complete as per technical specification. "

2

-

-

... More
od182410/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for 2C 1.5sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.

4

-

-

... More
od182411/2021_2022 : Supply of 2C 1.5sqmm 1.1 kV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.

322

-

-

... More
od182412/2021_2022 : Supplying and termination of UV Resistive MC4 Connectors suitable for terminating 4 Sq. mm copper cables(Male Female Connectors). Y connector at Inverter end also shall be measured under this item.The item includes all necessary accessories tape etc as required complete as per techical specififcation.

192

-

-

... More
od182413/2021_2022 : Supply and laying of Single core 4 Sq. mm Unarmoured copper Solar cables from Modules to String Combiner / Monitoring Box/inverter. The item includes all necessary accessories clamp, ties etc as required complete as per techical specififcation.

900

-

-

... More
od182414/2021_2022 : Supply fabrication, erection of Mounting structures for solar panels with Hot dip galvanized GI rectangular Tubes. The Mounting structure should have 40mm GI angle section for routing 4 Sq. mm DC cables between Modules and Modules to cable trays, including necessary clamps, welding, nuts, bolts, etc. Mounting structure shall be fabricated for group of panels(4 Nos) as per technical specification. (Item shall be measured against number of panel)

24

-

-

... More
od182415/2021_2022 : Supply, installation testing and commissioning of MONO PERC module solar photovoltaic panels of total of 6kWp rating meeting IEC 61215 (revised) / IS 14286 / IEC 61646 standards IEC 61730-1 with minimum efficiency of 19.5% with all accessories as per the tender specifiation.

2

-

-

... More
od187783/2021_2022 : Supply, Installation, Testing and Commissioning of Grid Tied solar string inverter of 25kVA rating , IP 66 rated, outdoor, three Phase output, true sinewave inverter system, with Maximum Power Point Tracker charge controller. Inverter should have Minimum 3 MPPTs, with 2 strings per MPPT. Minimum protection required shall be over voltage/surge, over load, short circuit and anti- islanding protection. Earthing shall be provided as per IEC standards. IGBT based true sine wave output. Unity Power factor(30kVA=30kW) . Accuracy of AC voltage control = +/-3%. Accuracy of AC frequency control = +/-1%. Frequency = 50Hz. Intelligent interface with LED/LCD display(Bluetooth/Wifi interface is also acceptable) . .Total Harmonic Distortion <3%”. The inverter should have all specification, protections, operational modes, etc as detailed in technical specification. The inverter should have in-built Type Surge protection device on AC and DC side. The item includes all necessary accessories like supports, canopy, AC Isolation boxes(with energy meter), Junction boxes, Combiner boxes, DCDBs, cabling from AC Isolation boxes to inverter, connectors, etc as required complete as per technical specification.

1

-

-

... More
od187789/2021_2022 : Supply, installation testing and commissioning of MONO PERC module solar photovoltaic panels of total of 24kWp rating meeting IEC 61215 (revised) / IS 14286 / IEC 61646 standards IEC 61730-1 with minimum efficiency of 19.5% with all accessories as per the tender specifiation.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.