Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Construction Of Covered Car Parking And Rest Room At Park Centre Building, Cyberpark Kozhikode.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KSITI_498025_1Bid Award Id
ViewTender No
KSITIL/CP/2022-23/08Tender Authority
Kerala State IT Infrastructure Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
10.47
-
-
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
9.9
-
-
6.3.1 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With F.P.S. ( non modular ) bricks
18.14
-
-
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
16.99
-
-
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
7.81
-
-
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
836
-
-
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
14
-
-
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
64
-
-
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
1.87
-
-
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
59.2
-
-
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
217.83
-
-
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
3.26
-
-
11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
3.6
-
-
od96510/2022_2023 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to bespecified by the manufacturer), of approved make with a basic price not less than Rs.300/sqm, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, over 12 mm thick bed of cement mortar 1:3 (1<br>cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
14.49
-
-
od96517/2022_2023 : Removing and refixing the existing paving tile in admin block front and side yard using 80/100 mm thick factory made cement concrete interlocking paver block with strong vibratory compaction and also including the rework of 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. As per standard specifications.
204
-
-
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x
19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm &
mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing
bead of appropriate dimension. ( Area of window upto 2.50 sqm).
11.07
-
-
9.147C.1 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67
x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead /
double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
5.67
-
-
od96524/2022_2023 : Providing and fixing glazing in UPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With float glass panes of 8 mm thickness (weight not<br>less than 20 kg/ sqm)
16.74
-
-
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
234.48
-
-
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
234.48
-
-
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
376
-
-
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
36.58
-
-
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
equivalent.
23.65
-
-
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
8761.58
-
-
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
28.56
-
-
od96534/2022_2023 : Providing and fixing acrylic LED signage with water proof acrylic material letters and inside LED light. As per design and standared specifications including cost of materials, laboursetc. complete.
3
-
-
od96535/2022_2023 : Providing and fixing roofing with Powder coated aluminium Trafford sheet 0.46mm thick and applying two coat of approved steel primer including all cost and conveyance of materials fittings,labour charges etc.complete
36
-
-
od96537/2022_2023 : Providing, supplying and fixing 12 mm toughened glass panels of size and shape as required and specified with sylicon sealed joints. including all cost and conveyance of materials fittings,labour charges etc.complete
259.78
-
-
od96538/2022_2023 : Providing, supplying and fixing aluminum expanded metal mesh ceiling panels, with pre-powder coated finish. The sheet shall be fixed using self drilling/ self tapping SS screws and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, all complete as per drawings, specification and direction of the Engineer in Charge
217.8
-
-
od96541/2022_2023 : Supplying and fixings 30 mm thick factory made Polyvinyl Chloride (PVC) door made of styles and rails of a UPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets, including cost of all fixtures labour charge etc. completed. As per standard specification.
1.68
-
-
50.12.2.5 : Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
79.2
-
-
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
135.2
-
-
Electrical
-
-
-
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp.
60
-
-
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
150
-
-
od96484/2022_2023 : Supply and Labour for laying of LT XLPE insulated, extruded, filled with moisture absorbent filler, tightly wounded, AL stranded conductor armoured cable, for working voltage up to 1100V, freely clamped on cable tray/wall or through trench, neatly dressed as required.<br>3c x 1.5 sqmm Armoured Cu cable
100
-
-
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 3.15 mm copper conductor ( 10 SWG)
40
-
-
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
2.4.4 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door
2
-
-
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
28
-
-
90.2.1.10 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Medium point
30
-
-
90.2.1.11 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium Point.
2
-
-
90.2.1.13 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
2
-
-
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required. (For light plugs to be used in non residential
buildings).
2
-
-
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2
-
-
90.2.1.14 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent Plug - Medium Point
2
-
-
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1
-
-
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
2
-
-
od96509/2022_2023 : Supply and installation of RJ 45 socket<br>
2
-
-
od96513/2022_2023 : Supply and installation of IP-65 junction box suitable for connecting 3c x 2.5 sqmm cu cable<br>
18
-
-
od96515/2022_2023 : Supply and installation of single phase 32A Socket with shutter, type-2(AC Charger wallbox for electric vehicles)<br>
3
-
-
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
2
-
-
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
100
-
-
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
40
-
-
od96521/2022_2023 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required <br>2x1 sq.mm + 1x1 sq.mm earth wire
75
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
180
-
-
od96523/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.18W Exterior Bulk Head light
5
-
-
od96525/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.10W LED T-Bulb wall light
2
-
-
od96526/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.20W tube with housing
2
-
-
od96527/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.10w Surface mount Ceiling light
17
-
-
od96528/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.8W Mirror light
1
-
-
od96529/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.9W spike lights
7
-
-
od96530/2022_2023 : Supply, fixing, testing and commissioning of following fixtures with all necessary accessories including cutting of false ceiling etc.<br>Bollard lights
20
-
-
od96531/2022_2023 : Supply, installation, testing and commissioning of 300 mm sweep Wall exhaust fan <br>
1
-
-
od96532/2022_2023 : Supply, installation, testing and commissioning of 1200 dia ceiling fan <br>
3
-
-
od96533/2022_2023 : Supply installation testing and commissioning of 1 KVA UPS with 30 minutes battery backup at full load (1 KVA) . The cost shall be inclusive of Structural steel supports (Stand) as per approved design.
1
-
-
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1
-
-
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
od96536/2022_2023 : Supply and providing first aid box
1
-
-
od96539/2022_2023 : Supply, erection, testing & commissioning of Fire extinguishers &Accessories all in accordance with the drawings and specifications. 4 kg ABC Dry chemical powder extinguisher
3
-
-
od96540/2022_2023 : Supply and laying of 1100V Rubber mat as per latest IS
2
-
-
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
200
-
-
90.6.9.2 : Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit. 2 Pair
50
-
-
od96542/2022_2023 : Preparation of necessary drawing and getting all necessary approvals/sanction, inspection etc.from all statutory authorities including all sundries expenses except statutory charges. Statutory charges shall be reimbursed only after producing valid proof.
1
-
-
Plumbing works
-
-
-
17.3.1 : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
od96483/2022_2023 : Supply and installation for Installation of Angle Cock <br>
1
-
-
od96485/2022_2023 : Supply and installation for Installation of Health Faucet <br>
1
-
-
17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
1
-
-
od96488/2022_2023 : Supply and installation of Angle cock with wall flange<br>
1
-
-
od96491/2022_2023 : Supply and Installation of CP Brass Shower Arm, Shower Head, complete with Supporting Accessories,wall chasing, refinishing etc as per building norms,<br>
1
-
-
od96493/2022_2023 : Supply andInstallation of CP Brass Diverter, complete with Supporting Accessories,wall chasing, refinishing etc as per building norms,<br>
1
-
-
od96494/2022_2023 : Supply and Installation of CP Brass Spout, complete with Supporting Accessories,wall chasing, refinishing etc as per building norms,<br>
1
-
-
od96497/2022_2023 : "Supply and Installation of site 20mm dia C.P brass Concealed and Exposed part of Stop Cock[inside bathroom] including cutting and making good the wall wherever required<br>(fordrinking water/cooler/waterfiltering units) "<br>
1
-
-
od96498/2022_2023 : Supply and Installation of 20mm dia Angle Valve including cutting and making good the wall wherever required
1
-
-
od96499/2022_2023 : Supply and Installation of 15mm dia C.P brass Bib tap/horse connector with wall flange including cutting and making good the wall wherever required <br>
2
-
-
od96500/2022_2023 : Supply ,Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards<br>25mm dia section Brass Valve
2
-
-
od96501/2022_2023 : Supply ,Installation,testing and commission of valves stated as follows with all supports,fixing and fitting alla as specified and shown on drawings and complying to relevent standards<br>32mm dia section Brass Valve
2
-
-
od96502/2022_2023 : Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness <br>50mm OD waste Piping
5
-
-
od96503/2022_2023 : Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness <br>75mm OD waste Piping
8
-
-
od96504/2022_2023 : Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.through floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness <br>110mm OD Soil Piping
8
-
-
od96505/2022_2023 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr /as per site condition and to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness <br>110mm OD Waste Piping
10
-
-
od96506/2022_2023 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having upto a depth of 1mtr /as per site condition and to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness <br>110mm OD Soil Piping
10
-
-
od96507/2022_2023 : "Supply and Installing at site UPVC multi inlet traps and outlet connections to pipes using solvent cement complete as required for floor drains.<br>Multi Inlet floor trap 110x75x50/40mm. "<br>
1
-
-
od96508/2022_2023 : Supply and Labour for Installation at site Concealed/open UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal suitable for the working pressure. Chasing of the walls/Supporting exposed pipes using rails at 60 cm intervals through duct, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period <br>20mm Nominal Dia ASTM
15
-
-
od96511/2022_2023 : Supply and Labour for Installation at site Concealed/open UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal suitable for the working pressure. Chasing of the walls/Supporting exposed pipes using rails at 60 cm intervals through duct, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period <br>32mm Nominal Dia ASTM
20
-
-
od96512/2022_2023 : "Supply Installation,testing and commissioning of masonary Manholes, valvechamber, sandtrap etc.. including escavation, backfilling, disposal, concrete waterproofing etc upto 1.5 mtr depth all in accordance with the drawing ,specification and relevant standards.<br>Size(as per the site condition): 45 cm x 45 cm "<br>
2
-
-
od96514/2022_2023 : "MANHOLE COVER<br>Supply, Installation ,testing & commisssioning of ISI marked FRP manhole cover and frame of (10 ton withstanding capacity) conforming to the latest relevant IS specifications<br>Size: 45 cm x 45 cm "<br>
2
-
-
od96516/2022_2023 : "Supply ,Installing and Leveling Pipe Supports Fabricated from GI Slotted Rails / Channels of corresponding as per the site condition with suitable for carrying the operating weight of pipe and the fluids , 12mm Dia GI Adjustable Threaded Rods and Anchor Fasteners on wall, U clamps etc.as appropriate. <br>50cm width with 60cm interval"<br>
8
-
-
od96518/2022_2023 : Supply and Installation of Robe Hook<br>
1
-
-
od96519/2022_2023 : Supply and Installation of Towel rod having 45 cm length<br>
1
-
-
od96520/2022_2023 : Supply and Installation of 10 cm dia Towel ring<br>
1
-
-
od96522/2022_2023 : Supply and Installation of 125x125mm CP Stainless Steel Gratings with Cockroach Protection for multi inlet floor trap.<br>
1
-
-
Landscaping works
-
-
-
od96481/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br>Rhododendron Blaauw's Pink
10
-
-
od96482/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br> Starlink Duranta
40
-
-
od96486/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br>JATROPHA
10
-
-
od96487/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br>Mahonia x media Lionel Fortescue
10
-
-
od96489/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br> IXORA DWARF
10
-
-
od96490/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br> ORIENTAL THUJA
10
-
-
od96492/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 30x30x30 cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The shrubs has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br> Azalea
10
-
-
od96495/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 60x60x60 cm, trees with girth minimum 30cm and height of tree not less than 600cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The trees has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br>Drooping Ashoka
2
-
-
od96496/2022_2023 : Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods covering the stem with necessary hay etc. caring and protecting the plants transported and unloaded at site till planting in pits of size 60x60x60 cm, trees with girth minimum 30cm and height of tree not less than 600cm. Appropriate length of soft wood props shall be provided as supports for the plants as directed. The trees has to be maintained for a period of 3 months after the entire planting of trees are completed. The rate shall include necessary labour, removal of rubbish and surplus earth etc.complete.<br>Maruthu
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements