Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date12 Nov 2024
Closing Soon10 Dec 2024
Tender Amount₹ 1,94,32,88,740 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

9346.35

-

-

... More
od90791/2024_2025 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

3830.62

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

15558.91

-

-

... More
od90740/2024_2025 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, for all leads and lifts as per direction of site Engineer-in-charge

8284.64

-

-

... More
od91252/2024_2025 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, for all leads and lifts complete as per direction of site Engineer-in-charge.

26619.6

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

12676

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

50

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

50

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

50

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

50

-

-

... More
CONCRETE WORKS

-

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1458.97

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

123.15

-

-

... More
od90725/2024_2025 : Providing & applying a coat of residual petroleum bitumen of grade of VG-10<br>of approved quality using 1.7kg per square metre on damp proof course after<br>cleaning the surface with brushes and finally with apiece of cloth lightly<br>soaked in kerosene oil.

123.15

-

-

... More
od90726/2024_2025 : Providing and laying cement concrete of grade 1:2:4 (1 Cement : 2coarse sand : 4 graded stone aggregate 6mm nominal size) for screed concrete properly mixed and consolidated, and the surface finished with power floater to achieve the required finish and slope including cost and conveyance of all materials, labour, curing, lead lift , etc. complete as directed by Engineer-in-Charge at all levels.

413.72

-

-

... More
od90730/2024_2025 : Providing and laying Light Weight Concrete using Thermocol beads/vermiculite of desired density for sunken portions inside the Building over and above Waterproofing works including compaction and vibration etc. complete. The rate shall include all leads and lifts, materials, labour, equipment and machinery, loading and unloading, transportation and all other incidental charges etc. all as complete and as directed by Engineer in charge. Prior approval shall be obtained from Engineer-In-charge for the Mix Design before execution of works.

150.94

-

-

... More
REINFORCED CEMENT CONCRETE WORK

-

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

4014.17

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

22238.93

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

14781.58

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

16571.99

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

10034.67

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

1007.83

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

5986.09

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

3065.77

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

60.9

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

20158.05

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3712073.23

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1463870.31

-

-

... More
od90736/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work upto plinth level

8937.92

-

-

... More
od90748/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work above plinth level upto floor V level

5440.03

-

-

... More
od92578/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work upto plinth level

161.21

-

-

... More
od92579/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 350 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work above plinth level upto floor V level

9.78

-

-

... More
od90749/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 360 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work upto plinth level

254.65

-

-

... More
od90750/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 360 kg/ cum. Additional cement requirement as per mix design shall be considered by bidder while quoting. All work above plinth level upto floor V level

2912.03

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

1228.63

-

-

... More
od91743/2024_2025 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1<br>Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-30 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting) .

175.5

-

-

... More
PILE WORK

-

-

-

... More
od90731/2024_2025 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used. Minimum cement content considered for pile in M-30 is @ 400kg/cum. 1000 mm dia piles

22140

-

-

... More
od91249/2024_2025 : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be<br>measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used. Cement considered for the pile in M-30 grade is 400 kg /cum. 600 mm dia piles

13900

-

-

... More
od95476/2024_2025 : Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Initial load test. Test load 2.5 times the safe capacity. (Safe capacity = 230 tonne)

2

-

-

... More
od95477/2024_2025 : Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Routine load test. Test load 1.5 times the safe capacity. (Safe capacity = 230 tonne)

3

-

-

... More
od95478/2024_2025 : Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Initial load test. Test load 2.5 times the safe capacity. (Safe capacity = 180 tonne)

2

-

-

... More
od95479/2024_2025 : Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Routine load test. Test load 1.5 times the safe capacity. (Safe capacity = 180 tonne)

3

-

-

... More
od95480/2024_2025 : Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Initial load test. Test load 2.5 times the safe capacity. (Safe capacity = 65 tonne)

2

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

4

-

-

... More
20.8.1 : Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 ( Part IV) for determining safe allowable lateral load on pile:Upto 50 tonne capacity pile.

3

-

-

... More
20.9 : Integrity testing of pile using Low Strain / Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note:- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority, keeping in view the quality control, type of soil strata & importance of the project.

1028

-

-

... More
WATER PROOFING

-

-

-

... More
22.22 : Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

1878.8

-

-

... More
od99661/2024_2025 : Providing & Applying polymer modified, flexible cementitious negative side waterproofing coating with elastic waterproofing polymers on interior wall and floor surfaces of water tanks, STP, lift pits, etc. in three coats @14.35 kg /10 sqm. one coat of self priming of cementitious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementitious waterproofing polymer (dilution with water in the ratio of 3:1 ) after surface preparation, edge chamfering, packing of pipes, etc., complete in all respect as per the direction of Engineer-in-Charge.

2298.45

-

-

... More
od99681/2024_2025 : Providing & applying solvent free food grade epoxy resin coating in water tanks above the waterproof coating or protective plaster or screed concrete whichever the case maybe in two coats, with the first coat of solvent free epoxy resin at 0.1 litre /sqm and after 8 hours applying a second coat of solvent free epoxy resin @ 0.1 litre /sqm complete in all respect as per the direction of Engineer-in-Charge. The application shall be done with a mechanical spray applicator to achieve a minimum DFT as specified by the manufacturer.

1564.44

-

-

... More
od99682/2024_2025 : Providing & applying of solvent free coal tar epoxy resin system to build a thick coating that protects concrete & metal from wide range of chemicals in STP, sewers, etc. above the waterproof coating or protective plaster or screed concrete whichever the case maybe in two coats above a priming coat as specified by the manufacturer, after surface preparation and all the required procedures complete in all respect as per the direction of Engineer-in-Charge.

734.01

-

-

... More
od99683/2024_2025 : Providing & applying positive side waterproofing to Raft Slab, Stitch Slab, footing, Grade slab, etc., using 1.2mm thick fully bonded pre-applied HDPE membrane with a film of pressure sensitive adhesive Complete in all respect as per the direction of Engineer-in-Charge. The waterproofing membrane shall comply with BS 8102 - 2009 for grades 1, 2 and 3 and Indian Standard 16471 : 2017 for Protection of structures against water from the Ground. Waterproofing membrane shall be supplied with side overlaps of 75mm provided on the self-adhesive selvedge and end laps using HDPE Sealed tape of 100mm wide. Membrane shall be installed in strict accordance with the manufacturer’s instructions and shall provide an intimate bond to resist water migration.

5381

-

-

... More
od99684/2024_2025 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., using flexible polymer modified elastomeric waterproof coating in 2 coats at a coverage rate of 16 sqm per 25 kg bag with interval period of 6 hours over a substrate with Saturated Surface Dry condition after surface preparation, chamfering the edges of wall and floor with cement mortar in 1:4 admixed with SBR @ @ 2 litres per 50 kg bag of cement after saturating the surface with water and applying a slurry primer coat with SBR, ponding for leakage test, pressure grouting if required, etc. complete in all respect as per the direction of Engineer-in-Charge. The applied material of Elastomeric waterproofing coating should have a Tensile strength as per ASTM D412-2013 > 1.5 N/mm², elongation at break (ASTM D412-2013) >200%, Adhesion to substrate (ASTM D4541:2002) greater than 1.4 N/mm², Shore A Hardness - 79 (ASTM D2240:2010) and crack bridging ability (ASTM C1305 Modified) - 2.0 mm ,Migration test (CFR 175-300 of UD FDA) etc.

1233.09

-

-

... More
od99685/2024_2025 : Providing and applying Acrylic based modified Polyurethane elastomeric Solar Reflective cum waterproofing coating on top of concrete roof in two coats at 0.5mm thickness over the primer in all respect as per the direction of Engineer-in-Charge. The primer layer is the same compound mixed with water in ratio 1:2 and applied at coverage of 8 - 10 sqm / litre. The single component coating shall be applied in 2 coats using roller or brush or aqueegee or airless spray at wet film thickness of 0.5mm per coat at coverage of 0.5 litre / sqm over the designated area. The concrete surface should be prepared by mechanical (mechanical grinding) to ensure a good bond between the coating and the substrate. The product shall have a solid content of 50%, Tensile strength >2Mpa (ASTM D412), Elongation >250% (ASTM D412), Shore A Hardness : 75 (ASTM D2240), Tear Strength : 13 N/mm (ASTM D624), Adhesion to substrate : 2 Mpa concrete failure (ASTM D4541), Crack bridging : 2mm ( ASTM C 836), UV resistance 1000 hours : Pass ( ASTM D4587) , Service Temperature : -10°C to +60°C ,SRI- 100% .

4182.99

-

-

... More
MASONRY WORK

-

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

555.8

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

552.07

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

33.56

-

-

... More
od90729/2024_2025 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete.

25.39

-

-

... More
od91822/2024_2025 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor five level upto floor ten level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete.

3

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

989.14

-

-

... More
od90741/2024_2025 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor Five level upto floor ten level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

255.87

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

30

-

-

... More
50.6.2.1 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

20

-

-

... More
od90746/2024_2025 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above floor five level upto floor ten level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately).

236.67

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

619.54

-

-

... More
MARBLE & GRANITE WORK

-

-

-

... More
8.2.2.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm

557.45

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

81.75

-

-

... More
8.4 : Extra for fixing marble/ granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.

125.77

-

-

... More
8.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

117

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

817.22

-

-

... More
16.92 : Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge

150

-

-

... More
7.32.2 : Stone work plain in Copings,Cornices, String courses and plinth courses, upto 75mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.White sand stone

21.6

-

-

... More
JOINERY &amp; CUBICLES

-

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

3.13

-

-

... More
9.20.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

146.52

-

-

... More
9.25.1 : Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured)Decorative type door

88.56

-

-

... More
9.24.1 : Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded ) (overall area of door shutter to be measured):Rectangular or square

14.4

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

440

-

-

... More
8.8.1.2 : Fastener with threaded dia 10 mm

200

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

45

-

-

... More
od100503/2024_2025 : Providing and fixing Rack and Pinion Door Closer with hold-open arm Closing force: 2/3/4 Tested according to EN 1154 Finish: Silver (having brand logo with ISI, IS : 3564, embossed on the body, for all door widths and weights, with necessary accessories and screws etc. complete. as per the direction of the Engineer - in - charge. Minimum cost of the door closer shall be Rs. 4122.

24

-

-

... More
od100494/2024_2025 : Providing and fixing premium quality stainless steel 304 grade door accessories for wooden double doors which includes H type Stainless steel pull handle of bar size 25 x 450mm C/C and having a total bar length of 550mm includes Stainless steel back to back fixing accessories (2 nos), SS Dead lock in 55mm backset including strike plate and screws (1 no.), double cylinder 60mm length with 3keys and fixing screws (1 no.), stainless steel round shaped lock escutcheon (1 no) all complete as per the direction of engineer - in - charge. Price of 1 no. of H shaped door handle should not be less than Rs. 3458 and lock set should not be less than Rs. 2644.

12

-

-

... More
od100271/2024_2025 : Providing and fixing 304 grade stainless steel door handle, mortise sash lock and lock cylinder assembly with SS square handle of minimum length 135 mm, mortise reversible latch sash lock of 55 mm back set and 72 mm centre to centre and euro profile double cylinder of 60 mm length all complete as per the direction of engineer in charge. The cost of lever, mortise sash lock and cylinder combined should not be less that Rs. 3884

45

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

45

-

-

... More
od100496/2024_2025 : Providing and fixing Stainless steel 304 grade half moon door stopper, ISI marked, with necessary screws etc. complete. Price of the door stopper should not be less than Rs. 318

24

-

-

... More
od100495/2024_2025 : Providing and fixing stainless 304 grade tower bolts for wooden doors with necessary screws etc. complete: 250x10 mm all complete as per the direction of the Engineer - in - charge. Rate of the towerbolt should not be less than Rs. 682.

24

-

-

... More
od90751/2024_2025 : Providing and fixing 1050mm x 2400mm size manual sliding door, using 38mm thick flush door shutters of single leaf, solid core of block board type bonded with phenol formaldehyde synthetic resin thermo pressed with 8mm thick teak wood external lipping. The construction procedure of the shutter should be as per IS:2202. The shutter shall be shop prepared for taking mortice lock or latches suitable with block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS:2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc; complete as directed. Providing and finishing the flush door shutters on both sides with 1.00mm thick approved make and shade laminate sheets at factory by hot pressing with grooves and lines in pattern as per the instructions of the Architect. The rate shall be inclusive of polishing the the lippings with PU polish upto the required level. The basic cost of 1.00mm thick laminate is Rs.400/sqm. The rate should be include the cost of supply and fixing one number approved make, SS316 grade Mortice Sash lock ST8100 type with approved type lever handle and internal thump turn in stainless steel satin finish, SS-316 grade with lock for end with Euro profile cylinder with external key operation and Internal thump turn and the strike plate and approved make SS sliding channel along with sliding arrangement in shutters including all accessories.

11

-

-

... More
od90752/2024_2025 : Supplying and fixing fire rated door with hardwares: Providing and fixing of Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory . Door frame shall be single rebate frame profile of size 125 x 55 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. .Door leaf shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. 200x300mm Vision lite wherever applicable should be provided as per manufacturers recommendation with a clip-on arrangement. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door. All doors and frames shall be finished with polyurethane aliphatic grade powder coating minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 2Hrs Fire Rated Door Unequal Double leaf 1500x2400mm with vision panel with hardware. All necessary hardware shall include Ball bearing butt hinges (SS 304). Fire rated Mortice sash lock , Euro Profile Cyl. , both side side key & one side thumb turn Length=65mm, Lever Handle SSS. Door closer with Std. arm. Lever action flush bolt, SC. Fire Rated Seal for Grooved Frame Profile C421 - EPDM Black

86

-

-

... More
od90753/2024_2025 : Supplying and fixing fire rated door with hardwares: Providing and fixing of Hollow metal fire rated doors as per IS 3614 part-1 & part-2 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory . Door frame shall be single rebate frame profile of size 125 x 55 mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. .Door leaf shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. 200x300mm Vision lite wherever applicable should be provided as per manufacturers recommendation with a clip-on arrangement. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door. All doors and frames shall be finished with polyurethane aliphatic grade powder coating minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 2Hrs Fire Rated Door FD2 Single leaf 1200x2400mm with vision panel :1200x2400mm with hardware . All necessary hardwares shall include Ball bearing butt hinges (SS 304). Fire rated Mortice sash lock , Euro Profile Cyl. , both side side key & one side thumb turn Length=65mm, Lever Handle SSS. Door closer with Std. arm. Lever action flush bolt, SC. Fire Rated Seal for Grooved Frame Profile C421 - EPDM Black

33

-

-

... More
od90754/2024_2025 : Providing and fixing of Hollow metal door at all levels from ISO 9001-2000 certified Manufacturer. The metal doors should be made from high grade galvanised steel stretched level sheet flush, with vision panel if required etc. Single /Double leaf to required sizes and approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be single rebate profile of size 125 x 55 mm made out of 1.20mm minimum thick galvanized steel sheet (18 gauge ). Frames should be mitered and field assembled with self tabs. Door frames should be prepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regular wear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber door silencers should be provided on the striking jamb. All door frames should be provided with backplate and anchor fasteners for installation on a finished plastered masonry wall opening. Door leaf should be 46mm thick flush double skin door with vision panel of suitable size. Door leaf shall be manufactured from 0.8mm (22 guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, shaft locks, flush pull and tower bolt etc. The edges should be interlocked with lock seam.All doors and frames shall be finished with polyurethane aliphatic grade powder coating minimum of 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. a).2Hrs Fire Rated Door Steel Door Single leaf 600x1500mm without vision panel with frame on Four sides & hardware set . 2 Ball bearing butt hinges of SS 304. Mortice Shaft Dead lock with Allen key , SSS. Flush Pull Handle

104

-

-

... More
od90755/2024_2025 : Providing and fixing of Hollow metal door at all levels from ISO 9001-2000 certified Manufacturer. The metal doors should be made from high grade galvanised steel stretched level sheet flush, with vision panel if required etc. Single /Double leaf to required sizes and approved consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be single rebate profile of size 125 x 55 mm made out of 1.20mm minimum thick galvanized steel sheet (18 gauge ). Frames should be mitered and field assembled with self tabs. Door frames should be prepared for suitable hardware as scheduled and should have necessary reinforcement to withstand regular wear and tear. All provision should be mortised, drilled and tapped for receiving the hardware. Rubber door silencers should be provided on the striking jamb. All door frames should be provided with backplate and anchor fasteners for installation on a finished plastered masonry wall opening. Door leaf should be 46mm thick flush double skin door with vision panel of suitable size. Door leaf shall be manufactured from 0.8mm (22 guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, shaft locks, flush pull and tower bolt etc. The edges should be interlocked with lock seam. For pair of doors astragals will be provided as required. 450x750mm Vision lite wherever applicable should be of size fixed with rubber beeding. The glass should be 4mm clear toughned glass. All doors and frames shall be finished with polyurethane aliphatic grade powder coating minimum of 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Steel Door Single leaf 900x1500mm with 450x750mm vision panel with frame on Four sides & hardware set . . 2 Ball bearing butt hinges of SS 304. Mortice Shaft Dead lock with Allen key , SSS. Flush Pull Handle

39

-

-

... More
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

19.44

-

-

... More
9.147C.1 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).

6.93

-

-

... More
9.147D.5 : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)

38.55

-

-

... More
od91213/2024_2025 : Providing and fixing glazing in UPVC door, window, ventilator shutters and partitions etc. including silicone application, etc. complete as per the architectural drawings and the directions of Engineer - in -Charge: With float glass panes of 5.50 mm thickness

41.97

-

-

... More
od91214/2024_2025 : Providing and fixing glazing in UPVC door, window, ventilator shutters and partitions etc. including silicone application, etc. complete as per the architectural drawings and the directions of Engineer - in -Charge.: With float glass panes of 4.0 mm thickness

18.72

-

-

... More
9.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).

18.72

-

-

... More
od91318/2024_2025 : Extra for providing 4 mm thick aluminium composite panel sheets on half glazed uPVC doors including all fixtures complete as per the direction of the engineer-in-charge.

13.77

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

266.76

-

-

... More
od100511/2024_2025 : Providing and fixing stainless steel 304 grade H shaped pull handles of size 25 x 450mm center to center and main bar full length 550mm includes Stainless steel back to back fixing accessories all complete as per the direction of the engineer - in - charge. Cost of the handle shall not be less than Rs. 3458.

124

-

-

... More
od100624/2024_2025 : Providing and fixing stainless steel 304 grade Bottom patch lock all complete as per the direction of engineer in charge. Cost of the materials shall not be less than Rs. 4100.

124

-

-

... More
od91218/2024_2025 : Providing and fixing urinal partitions with 12 mm thick compact laminate HPL boards of single colour of approved make, size of the board 450 mm x 900 mm, overall height of 1850 mm (including bottom gap of 650 mm) including SS accessories of 316 grade, like SS right angle brackets, etc. all complete as per the approved drawings and as approved by the Engineer-in-charge.

103

-

-

... More
od90757/2024_2025 : Providing and fixing Modular Toilet cubicles of approved make made of 12 mm HPL board complete set including partitions and S.S 316 grade accessories such as Top Rail, Coat hook with Door stopper, Occupancy indicator, Door Knob, & Channel; Channel, screws, Adjustable Legs, etc. complete and with Rubber strip for the groove in the Pilaster for reducing noise.; The cubicle shall be of Pilaster & S.S Leg Floor-mounted type with overhead bracing taking into consideration the stability of the panels. Top bracing shall be connected to the wall for additional support and stability. Wall brackets and corner brackets to be used while assembling the cubicles. In addition, the door should have a self-closing hinge and an indicator slip latch or bolt with a knob outside and 2 coat hooks inside. Compartment depth & width: as per the approved drawings with door size 600 mm x 1760 mm and overall height: 2050 mm including 150 mm ground clearance.

182

-

-

... More
STEEL WORK

-

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

18304

-

-

... More
od90724/2024_2025 : Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

1104.4

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

135310.39

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

5000

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

10642.13

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

5697

-

-

... More
od90738/2024_2025 : Providing and fixing M.S. fan clamp type I or II of 10 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

250

-

-

... More
26.65 : Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).

10

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

21.6

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

6

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

21.6

-

-

... More
ROOFING & PARTITIONS

-

-

-

... More
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

986.96

-

-

... More
12.54.1 : Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of sixe38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring 'T' with :GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5mm thick with 25 mm height, ,made of G.I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending .

506.41

-

-

... More
12.53 : Providing and Fixing 15 mm densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone /cosmos /Hexa or equivalent of size 595x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main 'T' of size 24 x 28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size (24x24x3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture (Spintone / Cosmos/hexa) in the grid, including cutting / making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever require. Main 'T' runners to be suspended from ceiling using G.I slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size of 85x30x0.8 mm, spaced at 1200mm centre to centre along main 'T' bottom exposed with 24 mm of all T- sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. value of 0.50 (Minimum), light reflection 85% non - combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC.

1255.4

-

-

... More
12.34 : Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183, density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire and mesh, for top most ceiling of building .Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS: 8183, density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire meh of 12.5 mm x 24 gauge wire and mesh, for top most ceiling of builing .

1110

-

-

... More
od90727/2024_2025 : Supplying and Fixing of Interior Aluminium Baffle Ceiling manufactured of approved make with approved Teak wood finish colour consisting of U-Shaped Profiles 50mm wide x 75mm deep x 0.6mm thick with inwardly returned edges of 6 - 9mm made from Aluminium Alloy 3105 grade. The baffle shall be manufactured on high speed, high precision roll forming machine with ARKU SIX Hi configuration roller levelling process to ensure the flatness and to avoid the failure of metal at corners which may occur normally on press brake machine. Baffles are Coil Coated on a Continuous Paint Line, Double baked and Roll formed from enamelled Corrosion Resistance Aluminium Alloy 3105 for higher strength and good Roll Forming characteristics. Baffles are fixed to the Baffle Aluminium Carrier & Distance between 2 baffles shall be 150mm C/c. and 100mm clear gap. Aluminium Carrier shall be fixed at a distance of 1.2mtrs to 1.5mtrs c/c and shall be suspended by means of G.I. Threaded Rod of 6mm diameter at a distance of 1.2mtr to 1.5mtrs c/c. The system should meet the required standards for Green Pro certification and should qualify as green product as per CII green products and services council. The manufacturer should be ISO 9001:2015 Quality Management System Certification compliant with in house testing facility and should have their own manufacturing plant in India. Aluminium U-Shaped Baffle Profiles shall be chromatised for maximum bond between metal and paint, enamelled twice under high temperature one side with full primer and Finish Coat, the other side (inner side) with a Primer Coating and Skin Coat on a Continuous Paint Line. Including all necessary fittings all complete as per the directions of the Engineer-in-charge.

40

-

-

... More
9.105.1 : Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated board conforming to IS : 2095 : part I

534.45

-

-

... More
od90732/2024_2025 : Straight Glazed Partition-Slim line of approved make: Providing and installation of full height straight glass partition from FFL to the bottom of false ceiling and fixing 12mm thick toughened and heat soaked glass and proprietary type anodized aluminium slimline sections of approved make. The sections shall be matt finish natural anodized and shall be a combination of male and female frames on all four sides as per the manufacturers specification. The rate shall be including the cost of all necessary hardwares, anodized aluminium jointing profile on edges of the glass in parallel glass joints, and anodized aluminium corner profile in corner glass joints including the cost of 12mm thick toughened and heat soaked glass.

513.14

-

-

... More
od90733/2024_2025 : Providing and fixing of frosted film of approved color as per required pattern and shape and as directed. The vendor shall submit required warranty certificates from the manufacture. (Basic cost Rs.1200/Sqm)

749.9

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

10

-

-

... More
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)

10

-

-

... More
od91272/2024_2025 : Providing and fixing UPVC rainwater gutters of size 220 mm including all required accessories and fixtures complete including connection to the down take pipe all complete as approved by the engineer in charge.

10

-

-

... More
FLOORING

-

-

-

... More
11.26.1 : Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick

1700.06

-

-

... More
11.27 : Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

238.46

-

-

... More
11.31 : Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.

1428

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

888.58

-

-

... More
od90734/2024_2025 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, walls, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).<br>Size of Tile 600x600 mm

3075.03

-

-

... More
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

3963.61

-

-

... More
11.50 : Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles

3963.61

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1996.89

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

487.03

-

-

... More
od90737/2024_2025 : Providing and laying of approved make 100% Optimum SD Nylon Tufted, Textured Loop Pile carpet tiles of density more than 6500 oz and20oz/sq.mtr of size 600mmx600mm or any standard size,permanent static control, solution dyed, pile height about 0.118inches with PVC free backing, colorfastness &gt; or =4 after 100hours, moth proof, stain resistant etc. complete, over existing flooring as per Manufacturer specification. The carpet should be ,class-1 fire rated ,antistatic, moisture barrier, etc. Plank/square (approved shade basic cost Rs.1200/Sqm). The rate shall be include the cost of the supply of carpet necessary adhesive. (Basic Rate Rs.2000 /sqm)

141.32

-

-

... More
11.16.2 : Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) :Medium shade pigment using 50% white cement and 50% ordinary cement

50

-

-

... More
FINISHING

-

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

41156.45

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

3629.07

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

21759.6

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

170

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

28924.53

-

-

... More
13.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

34517.36

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

34517.36

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

1988.63

-

-

... More
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1290.1

-

-

... More
od94071/2024_2025 : Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:<br>1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.<br>2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.<br>3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.<br>4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)

582.33

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

2717.51

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

2313.83

-

-

... More
od100240/2024_2025 : Providing and applying premium quality exterior waterproof putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

6628.44

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

6628.44

-

-

... More
STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

168842.1

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

13872.41

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement

12903.77

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

1290.37

-

-

... More
25.6 : Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). (ii) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face #2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25 - 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

968.64

-

-

... More
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

7232.94

-

-

... More
od91251/2024_2025 : Facde performance test are to be conducted on structural glazing system from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work.<br>Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283- 04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml.<br>

1

-

-

... More
Miscellaneous Items

-

-

-

... More
od90742/2024_2025 : Supply and Fixing of looking mirror work as per size given, Mirror should be at least 6 mm thk as per approved make with one inch Bevelling and will be paste on 12 mm waterpoof Plywood included fixing, loading and unloading. Complete direction as per engineer in-charge.<br>

119.96

-

-

... More
od90743/2024_2025 : Supply and installation Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for horizontal openings in floors or slabs after passing Plastic or Metal Pipes. The mortar shall be a lightweight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. Fire intumescent sealants (for plastic pipe diameter <= 2''), Intumescent Wraps (for plastic pipe diameter > 2'' & <= 6'' mm) & Intumescent Collars (for plastic pipe diameter > 6'' mm & <= 10'') shall be used around Plastic Pipes or Conduits to provide minimum 2 hours fire rating when tested in accordance with UL 1479 standards. The products shall be age tested as per Dafstb and DIBT standards. The products shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The products shall be UL listed & classified and shall bear the UL approval logo on the packing. The application to be executed by manufacturer approved firestop contractor. All complete as directed by the engineer-in-charge. Penetrants Occupancy at 15%. For Plumbing /Other PVC pipes shaft

38

-

-

... More
od90744/2024_2025 : Supply and installation of Fire stop mortar system with minimum 2 hours fire rating in services passing through fire rated walls and floors made of concrete, masonry, metal, gypsum partition when tested in accordance with UL 1479 standards, for horizontal openings in floors or slabs after passing service lines like Metal Pipes or Ducts. The mortar shall be a lightweight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. Acrylic fire stop sealant with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation. Fire intumescent firestop sealant with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes with insulation. The products shall be age tested as per Dafstb and DIBT standards. The products shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The products shall be UL listed & classified and shall bear the UL approval logo on the packing. The application to be executed by manufacturer approved firestop contractor. All complete as per the direction of the engineer-in-charge. Ratio of Mortar to sealant is 70% & 5% Respectively and 25% Penetrants Occupancy. For AHU/HVAC/ Land scape Terrace Services Shaft

196.5

-

-

... More
od90745/2024_2025 : Supply and installation of Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines like Metal Pipes. The mortar shall be a lightweight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be UL listed & classified and shall bear the UL approval logo on the packing. The application to be executed by manufacturer approved firestop contractor. All complete as per the approval of the engineer-in-charge. Penetrants Occupancy is 15%. For Fire Shaft

38

-

-

... More
od90747/2024_2025 : Supply and installation of Fire Barrier mortar with minimum 2 (two) hours fire rating when tested in accordance with UL 1479 standards, for fire rated vertical openings in floors or slabs and floors made of concrete, masonry, metal, gypsum partition, after passing service lines like Cable,Cable trays, Bus Duct or Metal pipes. The mortar shall be a lightweight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. Expanding fire stop foam with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used to seal areas that are highly dense or are not accessible and cannot be sealed with fire stop mortar properly. The expanding foam shall expand minimum seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The expanding foam shall also be repenetratable. The products shall be age tested as per Dafstb and DIBT standards. The products shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The products shall be UL listed & classified and shall bear the UL approval logo on the packing. The application to be executed by manufacturer approved firestop contractor all complete as per the approval of the engineer-in-charge. Ratio of Mortar to foam as 75% & 10% Respectively and 15% Penetrants Occupancy. For Electrical Shaft/Busbar/Communication Shaft

65.6

-

-

... More
od91776/2024_2025 : Providing and fixing polypropylene rungs of size 25 mm Thick x 175 mm 265 mm length reinforced with 10 mm steel Rod, for steps in RCC walls as per drawing and or as directed at site including fixing in position in line and levels etc. complete

300

-

-

... More
od91777/2024_2025 : Providing and applying of swellable type water stop tape, 10mm x 20mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

500

-

-

... More
od94008/2024_2025 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 6 kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

1000

-

-

... More
od95227/2024_2025 : Supply of drainage composite realized by thermo bonding a draining core in extruded monofilaments (GMA) with two filtering nonwoven geotextile and cores of “N” configuration of longitudinal parallel channels shall be used. The drainage core shall be made of polypropylene UV stabilized by carbon black and made by extruded monofilaments set in longitudinal parallel configuration and the external geotextile shall be made of polyethylene or polypropylene or polyester or similar fibres manufactured through machine made process of heat bonding or needle punching techniques all complete as per the design and as approved by the Engineer - in - charge

2800

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

5

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

5

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

5

-

-

... More
od95494/2024_2025 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (light duty) the weight<br>of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

10

-

-

... More
od95495/2024_2025 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

10

-

-

... More
od100461/2024_2025 : Providing, Fabricating & fixing of HPL Sheet cladding to the fabricated MS Gate or other works using Aluminium power coated rivets all complete as per the design and approved by the Engineer - in - charge.

22.5

-

-

... More
Road Works

-

-

-

... More
od90822/2024_2025 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.<br>With Material conforming to Grade - V

1378.59

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

1723.22

-

-

... More
od90832/2024_2025 : Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregates in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction / expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge ( Item of joint fillers, sealants, dowel bars with sleeve/tie bars to be paid separately). Note: Cement content considered in M-30 is @340 kg/cum. Addition cement requirement as per the mix design shall be considered by the bidder while quoting.

1009.81

-

-

... More
16.44 : Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete.

574.91

-

-

... More
16.45 : Providing and fixing in position pre- moulded joint filler in expansion joints.

7817.99

-

-

... More
od90874/2024_2025 : Providing and laying in position bitumen hot sealing compound for expansion<br>joints etc.<br> Using grade 'A' sealing compound

7817.99

-

-

... More
od91018/2024_2025 : Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M - 40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6 mm coarse aggregate, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

956.81

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

60.28

-

-

... More
16.90 : Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

417.14

-

-

... More
16.48.1 : Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS: 164, on bituminous surface in white / yellow shade, including cleaning the surface of all dirt, scales oil, grease and foreign material etc. complete.New work (Two or more coats)

167.58

-

-

... More
16.50 : Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D 4280. The slope of retro-reflective surface shall be 35 (+/-5) degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I : 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-Charge.

561

-

-

... More
16.59.1 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Mandatory / Regulatory sign boards of 900 mm diametre with support length of 3750 mm

5

-

-

... More
16.59.2 : Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC: 67- 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x 5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-Charge.Cautionary / warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

5

-

-

... More
Landscape works

-

-

-

... More
30.2.2 : Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

1063.79

-

-

... More
30.2.3 : Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

266.03

-

-

... More
30.2.25 : Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

266.03

-

-

... More
30.2.4.1 : Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

133.01

-

-

... More
30.2.4.3 : Screened through sieve of I.S. designation 4.75 mm

133.01

-

-

... More
30.2.6 : Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

14370

-

-

... More
30.2.7 : Fine dressing of the ground

5319.48

-

-

... More
30.2.8 : Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

1595.85

-

-

... More
30.2.9 : Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

1595.85

-

-

... More
30.2.14.2 : Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep

250

-

-

... More
30.2.14.3 : Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 60 cm dia, and 60 cm deep

30925

-

-

... More
30.2.34 : Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge.

4255.58

-

-

... More
30.2.57.1 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

250

-

-

... More
30.2.57.2 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Shrubs plants (for 200 nos.=427.45/200)

9014

-

-

... More
30.2.57.3 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per Hedge plants (for 300 nos.=427.45/300)

21911

-

-

... More
od91022/2024_2025 : Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-char

1862

-

-

... More
od91023/2024_2025 : Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91024/2024_2025 : Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91025/2024_2025 : Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.

50

-

-

... More
od91026/2024_2025 : Providing and displaying of Areca Palm plant, having ht. 2.40 m to 2.70 m with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of Bucket type cement pots & as per direction of the officer-in-charge

50

-

-

... More
od91027/2024_2025 : Providing and stacking of Rhapis Palm plant, having ht. 75 cm to 90 cm with 15 to 18 equal suckers, well developed, full of fresh and healthy leaves from bottom to top in 35 cm PVC Pots/C.Pots & as per direction of the officer-in-charge.

50

-

-

... More
od91028/2024_2025 : Providing and stacking of Plumeria alba dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

50

-

-

... More
od91029/2024_2025 : Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge.

50

-

-

... More
od91030/2024_2025 : Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge.

50

-

-

... More
od91031/2024_2025 : Providing and stacking of Syngonium variegated, of height 20-30 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.

3325

-

-

... More
od91032/2024_2025 : Providing and stacking of Euphorbia milli hybrid variety, having ht.30 cm to 45 cm with multibranch, full bloom, fresh and healthy leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge

3325

-

-

... More
od91033/2024_2025 : Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multibranched in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

3325

-

-

... More
od91034/2024_2025 : Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.

8511

-

-

... More
od91035/2024_2025 : Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91036/2024_2025 : Providing and stacking of Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in p.bag of size 25 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91037/2024_2025 : Providing and stacking of Ficus blackii (F.vivion) of height 45-60 cm. with 6-8 branches healthy foliage in earthen pots of size 25 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91038/2024_2025 : Providing and stacking of Euphorbia pulcherrima (dark red double bracts) well branched of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.

1192

-

-

... More
od91039/2024_2025 : Providing and Displaying Ficus resnold piller type Topairy well developed with fresh & healthy 210 to 240 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.

50

-

-

... More
od91040/2024_2025 : Providing and displaying of Livistona palm plant, having ht. 60 cm to 75 cm, well developed with 8 to 10 leaves, fresh & healthy foliage in 30 cm size of Earthen pot/Plastic pot . as per direction of the officer-in-charge.

50

-

-

... More
od91041/2024_2025 : Providing and Displaying of Araucaria cookie having ht. 90 cm to 120 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 25 cm size of earthen pot/plastic pot & as per direction of the officer-in-charge.

50

-

-

... More
od91042/2024_2025 : Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officerin-<br>charge.

50

-

-

... More
od91043/2024_2025 : Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35-40 cm well developed in big size HDPE bags as per direction of the officer-in-charge.

50

-

-

... More
od91044/2024_2025 : Providing and stacking of Tradescantia zebrina having in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.

3325

-

-

... More
Interior & Furniture

-

-

-

... More
od91052/2024_2025 : SOFA 03 SEATER<br>Fabric / Leatherite Finisih as per approved shade.<br>Providing & placing 3 seater sofa -Fully upholstered / PU Foam cushioned sofa in leatherite/Fabric as per image made out of good quality Seasoned Hard wood frame work and hard wood arm rest under carriage inclusive of 100 mm thick in seat and 75mm thick in back cushion of high density (45+/- Kg/Cum) PU foam, upholstered with leatherite of approved shade & texture complete as directed .Legs shall be polished wood with soft shoes Overall size of 3 Seater sofa is 1950(L) X 760(D) X 750-850(H) mm, Seat Height : 450mm .

14

-

-

... More
od91053/2024_2025 : Supply and installation of Staff Chairs / Conference Chairs / MD Visitor Chairs : Back Height - Medium Back<br>Back Finish - Mesh with Lumbar Support<br>Back Mesh Color - Black<br>Seat Finish - Fabric<br>Seat Fabric Color - Black<br>Seat Height Adjustment - Pneumatic<br>Mechanism Type - Synchronized Tilt<br>Back Tilt Lock - Upright Position<br>Back Tilt Tension - Adjustable<br>Armrests Type - 1-D PP Adjustable <br>Base Type - 5-Star in Black Nylon base<br> <br>WARRANTY: 3 Years from the date of invoice

54

-

-

... More
od91054/2024_2025 : Supply and installation of “RECEPTION” table of Size 1800mm (W)x900mm (D)x1200mm (H) with 25mm thick E1 grade pre-laminated particle board tabletop with matching edge banding and aluminium flip up of size 500mm(W) x 135mm(D) only anodized finish. Above Tabletop, 18mm Thick pre-laminated particle board Top and 25mm Thick pre-laminated particle board at front with support beams shall be considered. UNDERSTRUCTURE shall be pre-laminated particle board Gable ends and MS Powder coated 30x40mm beams shall be considered to support tabletop. WIRE MANAGEMENT shall be MS-Powder coated wire tray with switch plate & PVC wire guard shall be considered. Side Storage Size shall be1050mm (W)x450mm (D)x750mm (H). SIDE/REAR STORAGE shall have Top - 25mm thick & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys neat as complete and as directed by the Engineer in charge.

3

-

-

... More
od91069/2024_2025 : Supply and installation of “EXECUTIVE ” cabin table of Size 1650mm (W)x600mm (D)x750mm (H), Side Storage of Size 1950mm (W)x450mm (D)x685mm (H), Side Storage of Size 2700mm (W)x450mm (D)x685mm (H) with 25mm thick pre-laminated particle board tabletop with matching edge banding and aluminium flip up of size 350mm(W) x135mm(D)only anodized finish. UNDERSTRUCTURE shall be Aluminium Powder coated Sole series legs (End Legs) and MS Powder coated 30x40mm beams shall be considered to support tabletop. MODESTY shall be MS Powder coated metal modesty with 450mm (H). WIRE MANAGEMENT shall be MS-Powder coated wire tray with switch plate & PVC wire guard shall be considered for wire management. SIDE/REAR STORAGE shall have Top - 25mm thick & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys. neat as complete and as directed by the Engineer in charge.

8

-

-

... More
od91070/2024_2025 : Supply and installation of “CEO” cabin table of Size 2200mm (W)x750mm (D)x750mm (H), Storage Size of 1800mm (W)x450mm (D)x750mm (H), Back Storage Size of 900mm (W)x450mm (D)x1800mm (H) with 25mm thick pre-laminated particle board tabletop with matching edge banding and aluminium flip up of size 350mm(W) x135mm(D)only anodized finish. UNDERSTRUCTURE shall be Aluminium Powder coated Sole series legs (End Legs) and MS Powder coated 30x40mm beams shall be considered to support tabletop. MODESTY shall be MS Powder coated metal modesty with 450mm (H). WIRE MANAGEMENT shall be MS-Powder coated wire tray with switch plate & PVC wire guard shall be considered for wire management. SIDE/REAR STORAGE shall have Top - 25mm thick & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys. neat as complete and as directed by the Engineer in charge.

1

-

-

... More
od91071/2024_2025 : Supply and installation of “U-SHAPE” conference table of Size 9350mm(W) + 1800mm(W)x 600mm(D) x 750mm(H) with 25mm thick pre-laminated particle board tabletop with matching edge banding and aluminium flip up of size 500mm(W) x 135mm(D) only anodized finish. Under structure End Legs shall be Aluminium powder coated Sole - 2 Way series + Mid legs: 60mm x 30mm MS-Powder coated Legs & MS-Powder coated beams are considered for supporting tabletop. Wire management shall be MS-Powder coated wire tray with switch plate and vertical cable raisers / PVC wire guard are considered for wire management neat as complete and as directed by the Engineer in charge.

1

-

-

... More
od91072/2024_2025 : Supply and installation of conference table of Size 4600mm(W) x 1200mm(D) x 750mm(H) with 25mm thick pre-laminated particle board tabletop with matching edge banding and aluminium flip up of size 500mm(W) x 135mm(D) only anodized finish. Under structure End Legs shall be Aluminium powder coated Sole - 2 Way series + Mid legs: 60mm x 30mm MS-Powder coated Legs & MS-Powder coated beams are considered for supporting tabletop. Wire management shall be MS-Powder coated wire tray with switch plate and vertical cable raisers / PVC wire guard are considered for wire management neat as complete and as directed by the Engineer in charge.

2

-

-

... More
od91073/2024_2025 : Supply and installation of Medium Height Storage of size 750Lx450Dx1200H mm made up of 0.8mm CRCA sheet duly powder coated having 2 adjustable shelves. The storage handles shall be recessed PVC handles . Hardware shall be of approved make, 3 Point Locking System having locks at Top, Middle and Bottom. Necessary levers shall be provided wherever necessary, neatly complete as directed by the Engineer in Charge.

20

-

-

... More
od91074/2024_2025 : Supply and installation of Metal Pedestal (2 File+1Box) of size 400Lx450x680H having 3 drawers made up of CRCA metal powder coated Mobile pedestal unit with 3 drawers. Upper 2 box drawers + 1file drawer provided with Inner Metal Powder Coating Boxing sliding with soft closure Telescopic channels with rollers consists of 05no's Castors with concealed handles and a single lock neatly complete and as directed by Engineer in Charge

30

-

-

... More
od91075/2024_2025 : Supply and installation of panel based curvilinear workstation of Size 1350mm (W1) + 1350mm(W2)x 600 mm (D1) x 450mm(D2)x 1500mm (H). Tabletop shall be 25mm thick prelaminated with matching edge banding with PVC flap 120mm(W) x 120mm(D) with provision in anodized finish only. Main spine shall be 60mm thick. Thick Above tabletop, each will have half Magnetic pinup board & Half Glass marker inside & rest all will be fabric hard board. Below tabletop, both sides shall be MS powder coated metal perforated tiles in main spine & skirting level raceways. RETURN SPINE shall be 60mm Thick. Above tabletop, each workstation shall have fabric hard board. Below tabletop, both sides shall be MS powder coated metal perforated tiles in main spine & skirting level raceways. UNDERSTRUCTURE shall have Aluminium Powder coated SOLE Legs & MS Powder coated 30x40mm beams shall be considered to support tabletop. WIRE MANAGEMENT shall consist of 2 level race ways - one at Below tabletop only at main spine & skirting level race way at main spine neat as complete and as directed by the Engineer in charge.

30

-

-

... More
od91093/2024_2025 : Pantry Chairs: Supply and installation of Polypropylene Polymer chair with Chrome finish base stackable Shell : White plastic.Shall consider various colour options as per requirement

32

-

-

... More
od91094/2024_2025 : Supply and installation of Pantry table Size:1200W x750D x 720H. : Work Top 25 mm thick pre laminated Particle board Surface with 2 mm thick PVC edge banding. Understructure shall be MS powder coated leg.

8

-

-

... More
od91095/2024_2025 : Supply and Installation of Conference Chair with following specification :Back Height - Medium Back<br>Back Finish - Mesh with adjustable lumbar support<br>Back Frame - Black Color<br>Seat Finish - Fabric<br>Seat Height Adjustment - Pneumatic<br>Mechanism - Synchronized Tilt<br>Back Tilt Lock - Upright Position<br>Back Tilt Tension - Adjustable<br>Armrests Type - 1D Height Adjustable<br>Armpads Type - Polyurethane<br> Polished Aluminium base

87

-

-

... More
od91096/2024_2025 : supply and installation of CEO Main Chair of following specifications Back Height - Medium Back with Adjsustable Head Rest<br>Back Finish - Mesh with adjustable lumbar support<br>Back Frame - Black Color<br>Seat Finish - Fabric ( Black)<br>Seat Height Adjustment - Pneumatic<br>Mechanism - Synchronized Tilt<br>Back Tilt Lock - Upright Position<br>Back Tilt Tension - Adjustable<br>Armrests Type - 1D Height Adjustable<br>Armpads Type - Polyurethane<br>Base Type - 5-Star in Black nylon<br>For Polished Aluminium base please add INR 5740<br>

2

-

-

... More
od91097/2024_2025 : Side/Coffee Table: Providing & Placing Corner TABLE 450X450X 450 MM :- Top & Legs is made of polished wood

16

-

-

... More
od94860/2024_2025 : Supply and installation of VISTA Ailanto 50 MM Wooden Venetian Blinds – Manual Operated or equivalent with Bass Wood Slats ; Width= 50mm (+/fill;0.5mm); Thickness= 3mm (+/fill; 0.5mm), Head rail 53 mm high and 63 mm wide made of aluminium alloy provided with matching shade of slats, Valance fitted in the head rail of height 50 mm, Head rail covered by two end caps made up of PVC, Drum & Cradle of moulded ABS components with high strength , Tilter Lock made up of aluminium & fitted inside the head rail, Cord lock fitted inside the head rail & made up of steel providing locking arrangement for the cord and stops the slats at the desired heights that prevents blind from crashing down, if released abruptly, Tilting Cord 2mm in diameter, braided high strength polyester fibre cord for maximum abrasion resistance and minimum elongation provided with matching shade of slats, wooden tassels fill; 2 nos., Lift Cord 2mm in diameter, braided high strength polyester fibre cord for maximum abrasion resistance and minimum elongation provided with matching shade of slats with wooden tassel fill; 1 no. and equaliserfill;1 no., Bottom Rail made of Bass Wood ; Width= 50mm (+/fill; 0.5mm), installation Bracket made up of Steel with spring loaded brackets, Tilting Rod made of steel of size 6 mm Square rod fixed in the tilter mechanism and drives the drum to rotate the Slats etc all complete as per directions of Engineer-in-charge

10

-

-

... More
od100852/2024_2025 : Supply and installation of VISTA Roller Blinds blackout Series Venice/ Volga Opaque or equivalent make with Control unit made of high strength reinforced plastic with clutch of wrap spring design, High carbon steel springs provided to transmit motion from driving to driven members of clutch mechanism., Clutch operated directionally by the use of endless beaded chain, Idler of high strength reinforced plastic, consisting of a centre shaft mounted on the bracket by using a plastic lock, metal sleeve inside the plastic lock provides bearing surface for the centre shaft, which rotates freely, providing smooth, quiet and long wearing operation, Head rail of aluminium extruded rail Powder coated in white, Control unit and Idler are mounted on the Head rail with powder coated M.S. brackets, Roller tube anodized extruded tube of high strength alloy, Control unit and Idler are fixed to the either ends of the tube, fabric of the blind is fitted to the tube with heavy duty adhesive tape, Bottom rail of aluminium extruded rail with a groove for fixing the fabric and power coated in white, fixed to the bottom of the fabric to keep the fabric in tension and straight using plastic fill, ABS end caps , Operating chain made of 4.5mm plastic beads moulded on 2.2mm thick polyester chord with pitch of the beads 6mm, Fixing brackets & clamps to fix the blind to the wall or ceiling. 'L' bracket made of mild steel and zinc plated, the clamp shall be made up of spring steel of thickness O.7mm and zinc plated, Roller tube of Aluminium alloy Extruded grooved tube anodized of size 32mm O.D. and weight; 0.27 kg/m Size: 38mm; O.D.; weight ; 0.38 kg/m Size; 50mm; O.D.; weight ; 0.60 kg/m Alloy & temp; 6063;T6 Fabric is fitted on the tube with double sided tape. Bottom Rail: Extruded Aluminium grooved section; powder coated in white Size: 21mm O.D. Alloy; HE9WP Weight;0.28 Kg/m. Fabric is fitted to the bottom rail with plastic fill. Bottom rail end cap; made of ABS. Fabric Blackout Polyester, Fabric Thickness 0.6mm, Fabric Weight +5% 330 GSM, Fabric Width 230 cm, Fire Resistance NFPA 701 AATCC 16;2003 4.5, Environmental Certification Green Guard Certified, Other Properties Anti-Fungal & Anti-Bacterial Fabric, etc complete as per directions of Engineer-in-charge.

150

-

-

... More
od94861/2024_2025 : Providing and fixing Pelmet for concealing the pull-down projector screens and blinds. The pelmet shall be made of 19mm thick BWR. ply finished with enamel paint of approved shade. It shall be of 'U' shape of size 150 x 150 mm and its bottom level shall be fixed flush with the adjoining false ceiling level so as to recess the pelmet. Rate to include all hardware and supports for sufficient rigidity and to receive the false ceiling perimeter channels.

75

-

-

... More
od94862/2024_2025 : Providing and Fixing pet panels of required size and colour including all accessories as per the architectural design and instruction by engineer incharge.

127.38

-

-

... More
od95046/2024_2025 : Providing and fixing of Honeycomb blinds made of Original Non-woven honeycomb shades having soft fabric appearance and high energy-efficient fabric with high tear strength constructed out of Anti-static, resilient, colour fast & sanitized treat 100% spun bonded non-woven polyester fibre and precision manufactured to form a hexagonal shaped Duette pleat. Pleat dimension ¾” Honeycomb within a Honeycomb” with 3 distinct air pockets for superior energy efficiency and increased insulation. Shadings<br>are duotone, with neutral tone facing the exterior and colour facing the interior. Being a Low shading co efficient will have following Comfort rating & solar optical properties. Fixing with easy drive operating system having HEADRAIL measuring 49.68 wide and 36.66mm deep & thick 1.27mm extruded from 6063 T6 alu. alloy & shall be powder coated to a smooth finish with a thickness of 40 microns. All cords & cord holes shall be fully concealed inside the fabric structure. As each of the hexagonal cells is formed individually, pleats operate independent of each other providing superior pleat retention & structure strength. INSTALLATION BRACKETS shall be of high-tension spring steel suitable for overhead & wall mounting 30mm Duette Hartford mounting bracket. POLYESTER CORD shall be 0.9mm in diameter & of woven hollow core. ENDCAP shall be moulded acrylic colour matched to the head & bottom rails. BOTTOM RAIL shall be a single channel section, measuring 30mm wide and 12.5mm deep & thickness 1-1.2mm extruded from 5005 H 16 alu. alloy & shall be powder coated with a smooth finish to a thickness of 15-25 microns. HOLD-DOWN BRACKET (optional) shall be moulded in clear acrylic. It incorporates a pin for engagement with the bottom rail end-cap. It shall be suitable for sill, face or side facing. CORD.EQUILISER shall be injection moulded from impact modified acrylic with a high flexural modulus. Approved make: Hunter Douglas, Phifer, Vista or equivalent. as per Manufacturer's instruction of approved make (Hunter Douglas Roller shades/ PHIFER / VISTA or equivalent) as per manufacturer's specification etc complete as per directions of Engineer-in-charge

150

-

-

... More
od95097/2024_2025 : Providing and fixing 6mm lacquered glass with 12mm ply backing with all necessary accessories wherever required as per the direction of Engineer in-charge.

100

-

-

... More
od95193/2024_2025 : Providing and fixing 100mm Aluminium skirting including all accessories as per the direction of Engineer in-charge.

150

-

-

... More
od95339/2024_2025 : Providing premium decorative high gloss laminate finish with plywood whereever necessary as per the instruction of Engineer in-charge. The cost includes all accessories and adhesives.

300

-

-

... More
Signages

-

-

-

... More
od99721/2024_2025 : Supply and Installation of Building top LED acrylic signage with Logo in three dimensional channel letters made of 1mm aluminium trim channel having 75mm side return and sides finished with powder coated with imported cast acrylic on front face. Each individual letter are illuminated frontlit with high quality ADS LED modules to provide bright and even illumination across entire sign face along with respective power supplies. All electrical fittings and fixtures to be made water proof as per the specifications. signs to be designed with an electronic programmable timer. Letters are fixed on MS frame (rate of which is to be considered in this item) and mounted on existing terace slab or prefabricated MS structures. The works include cost of all including fixing at all heights complete as per the direction of the engineer - in - charge.

50

-

-

... More
od99722/2024_2025 : Supply and Installation of acrylic LED signage with letters and logo as three dimensional channel letters made of 1mm Aluminium trim channel having 60mm side return and sides finished with powder coated with imported cast acrylic on front face. Each individual letter are illuminated frontlit with high quality ADS LED modules with to provide bright and even illumination across entire sign face along with respective power supplies. All electrical fittings and fixtures to be made water proof as per the design. Signs to be designed with an electronic programmable timer. Letters are fixed on MS frame (the cost of which is included in this item) and mounted on existing concrete structures or MS structures. The works include cost of all including fixing at all heights complete as per the direction of the engineer - in - charge.

10

-

-

... More
od99723/2024_2025 : Providing and installing in position sign boards made out of 1.5 mm thick 304 grade stainless steel with computer cut with texts written to recommended height in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes, Letter height, Colour, Back ground, language and mounting height of the board shall be fixed at all height/ as per drawing

9

-

-

... More
od98123/2024_2025 : Providing and fixing 3D acrylic signage including letters and logo as per the approved design and drawings, finishing with PU coat of approved colour and fixing over the existing wall surface using approved fittings all complete as per the direction of Engineer - in - charge

15

-

-

... More
od98124/2024_2025 : Providing and fixing of building signage with logo as per the drawing and following specification-Sign to be made of 1 inch Projector SS 304 Grade Powder coated with the required colour shade. All the joint should me made watertight. The signages to be fixed on the structural ACP with required sizes as per the design/drawing. The item includes design of supporting arrangement, fabrication, installation and commissioning of the signages with mounting ACP but excludes supporting structural framing works. The work includes all complete at all heights as per the design and as approved by the Engineer – in – charge.

15

-

-

... More
TUBEWELL WITH SUBMERSIBLE PUMP

-

-

-

... More
23.2.1.3 : Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer- in- charge, beyond 90 metre & upto 150 metre depth below ground level.All types of soil400 mm dia

200

-

-

... More
23.3.3 : Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia

150

-

-

... More
od25899/2023_2024 : Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer - in-charge<br>200 mm nominal size dia

120

-

-

... More
23.8 : Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine /medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in- charge.

30

-

-

... More
23.12 : Development of tube well in accordance with IS: 2800 (Part I) and IS : 1189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer - in-charge.

60

-

-

... More
23.14.3 : Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS : 2800 ( part I), including ecessary bolts & nuts of required size complete.200 mm clamp

2

-

-

... More
18.32.1 : Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

5

-

-

... More
18.37.1 : Constructing masonry chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for water meter complete with C.I double flap surface box 400x200x200 mm ( inside ) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

3

-

-

... More
19.33 : Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

7

-

-

... More
od192744/2023_2024 : Providing & Fixing, testing and commission, of open well submersible Type Water Transfer Pump, for pumping water from Underground treated water tank to overhead domestic water tank, including level switches, control wires ,starter etc.The price shall inclusive of all connected electrical work. Three phase 3.7KW/5 HP, submersible type clear water pump with,65 mm suction and 50 mm delivery suitable for 28 to 40 mtr head and 8.0 to 3.8 LPS discharge respectively. , 1 working +1 standby, three phase, 415V, AC supply Pumping from sump to R&D OH tank/ STP tank to CDC OH tank<br>KOS538<br>

2

-

-

... More
od192748/2023_2024 : Providing & Fixing, testing and commission, of open well submersible Type Water Transfer Pump, for pumping water from Underground treated water tank to overhead domestic water tank, including level switches, control wires ,starter etc.The price shall inclusive of all connected electrical work. Three phase 5.6KW/7.5 HP, submersible type clear water pump with,65 mm suction and 50 mm delivery suitable for 40 to 48 mtr head and 9.0 to 5 LPS discharge respectively. , 1 working +1 standby, three phase, 415V, AC supply Pumping from sump to CDC OH tank<br>KOS1.525<br>

2

-

-

... More
od192754/2023_2024 : Providing & Fixing, testing and commission, of open well submersible Type Water Transfer Pump, for pumping water from Underground rain water tank to raw water tank,underground including level switches, control wires ,startor etc.The price shall inclusive of all connected electrical work. Three phase 0.75KW/1 HP, submersible type clear water pump with,32 mm suction and 25 mm delivery suitable for 8 to 22 mtr head and 4.8 to 1.6 LPS discharge respectively. , 1 working +1 standby, three phase, 415V, AC supply Pumping from Rain water tank to Raw water tank<br> KOS – 123M<br>

1

-

-

... More
od192762/2023_2024 : Providing & Fixing, testing and commission, of bore well submersible Type Water Transfer Pump, for pumping water from Borewell to domestic water tank,underground including level switches, control wires ,startor etc.The price shall inclusive of all connected electrical work. Three phase 5.5KW/7HP, submersible type water filled with 4 inch delivery suitable for 36 to 64 mtr head and 4.6 to 2.0 LPS discharge respectively. , 1 working , three phase, 415V, AC supply Pumping from Borewell to domestic tank<br>

2

-

-

... More
od193837/2023_2024 : Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer - in-charge 200 mm nominal size dia RMS pipe 200 mm.

120

-

-

... More
19.4.3.1 : Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith common burnt clay F.P.S (non modular) bricks of class designation 7.5

6

-

-

... More
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885

32

-

-

... More
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885

32

-

-

... More
19.28.1 : Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement:4 coarse sand) with pre -cast R.C.C vertical grating complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

28

-

-

... More
od248672/2023_2024 : supply of Three phase 0.75KW/1 HP, submersible type clear water pump with 32 mm suction and 25 mm delivery suitable for 8 to 22 mtr head and 4.8 to 1.6 LPS discharge respectively. <br>@ 20 meter head discharge will be 144 LPM.<br>

1

-

-

... More
SEWAGE AND DRAINAGE

-

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

75

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

302

-

-

... More
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2

75

-

-

... More
od192624/2023_2024 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 6Kg.<br>PVC pipe 200 mm

302

-

-

... More
od192625/2023_2024 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 4 kg.<br>PVC pipe 200 mm

695

-

-

... More
od192867/2023_2024 : Providing & Fixing, testing and commission, of submersible Type Water Transfer Pump, with control wires ,startor etc.The price shall inclusive of all connected electrical work. Three phase 0.75KW/1 HP, Sewage submersible pump with , 50 mm delivery suitable for 6 to 12 mtr head and 336 to 145 LPS discharge respectively. Particle handling size 20mm , 1 working +1 standby, three phase, 415V, AC supply Pumping Irrigation line/ collection pit CDC to STP. ETERNA 750CW or equivalent

3

-

-

... More
od192838/2023_2024 : Providing & Fixing, testing and commission, of submersible Type Water Transfer Pump, for pumping water from Collection Pit to STPtank with including level switches, control wires ,startor etc.The price shall inclusive of all connected electrical work. Three phase 2.2KW/3 HP, Sewage submersible pump 50 mm delivery suitable for 8 to 20 mtr head and 590 to 202 LPM discharge respectively. Particle handling size 20mm , 1 working +1 standby, three phase, 415V, AC supply Pumping from collection pit to STP.<br>ETERNA 2200CW or equivalent.

2

-

-

... More
19.6.1 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:100 mm dia R.C. C pipe

30

-

-

... More
19.6.2 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. pipe

10

-

-

... More
19.6.3 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:250 mm dia R.C. C. pipe

10

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal

12

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

1

-

-

... More
18.59.2 : Providing and fixing C.I double acting air valve of approved quality with bolts, nuts, rubber insertion etc. complete ( The tail pieces, tapers etc. if required will be paid separately):80 mm dia

1

-

-

... More
18.54.1 : Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms

11

-

-

... More
od191662/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>UPVC pipe 65 mm

50

-

-

... More
od191663/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block <br>mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.UPVC pipe 50 mm

550

-

-

... More
od192249/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>UPVC pipe 40 mm for 10 mtr<br><br>

10

-

-

... More
od192596/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>UPVC pipe 32 mm for 10 mtr<br>

119

-

-

... More
od192603/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>UPVC pipe 25 mm for 10 mtr<br>

428

-

-

... More
od192626/2023_2024 : Supply ,fixing,testing and comissioning of the Valves of cast iron lever operated slim seal type valves of CI body and spheroidal iron disc with nitrile rubber seal ,tested 10KG sqmm confirming BS 5155 /MF6 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.<br>Butterfly Valve 100mm<br>

1

-

-

... More
od192628/2023_2024 : Supply ,fixing,testing and comissioning of the Valves of cast iron lever operated slim seal type valves of CI body and spheroidal iron disc with nitrile rubber seal ,tested 10KG sqmm confirming BS 5155 /MF6 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.<br>Butterfly Valve 65mm

2

-

-

... More
od192633/2023_2024 : Supply ,Fixing ,testing andComissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>Ball Valve 20mm<br>

5

-

-

... More
od192634/2023_2024 : Supply ,Fixing ,testing and Commissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>Ball Valve 25mm

7

-

-

... More
od192635/2023_2024 : Supply ,Fixing ,testing and Commissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>Ball Valve 32mm

4

-

-

... More
od192705/2023_2024 : Supply ,fixing,testing and comissioning of the Valves of cast iron lever operated slim seal type valves of CI body and spheroidal iron disc with nitrile rubber seal ,tested 10KG sqmm confirming BS 5155 /MF6 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc<br>Butterfly Valve 50mm

5

-

-

... More
od193541/2023_2024 : Supply ,Fixing ,testing and Commissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>Ball Valve 50mm

12

-

-

... More
od193548/2023_2024 : Supply and fixing of plastic ball float valve with gun metal lever of IS specification make and approved by the client / consultant for muncipal water inlet pipe to UG sump.<br>25 mm dia<br>

1

-

-

... More
od193550/2023_2024 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>100 mm dia<br>

5

-

-

... More
od193553/2023_2024 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>65 mm dia

3

-

-

... More
od193555/2023_2024 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>50 mm dia

14

-

-

... More
od193557/2023_2024 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>40 mm dia

4

-

-

... More
od193563/2023_2024 : Supplying & Fixing at site in position Fabricated u PVC Astm Sch 80 Puddle flanges in the underground and overhead water tanks as per the drawings and the requirement of the Project Manager.<br>25 mm dia

1

-

-

... More
od193611/2023_2024 : Providing of 4 pair 1.5 sq mm cable as control cable of liquid water level controller tincluding ISI Heavy duty 20mm conduit<br>

300

-

-

... More
od193615/2023_2024 : Providing & fixing 130 mm size Floor clean outs stainles steel as per the directions of engineer in charge with all the necessary fittings.<br>

12

-

-

... More
od193617/2023_2024 : Providing & fixing of plastic type P-Trap with all the necessary accessories required for the installation.<br>40 mm dia

11

-

-

... More
od193620/2023_2024 : Providing & fixing of plastic type P-Trap with all the necessary accessories required for the installation.<br>Supply 32mm

63

-

-

... More
18.60.1 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. ( The tail pieces if required will be paid separately):80 mm dia nominal bore

1

-

-

... More
ACTIVATED MEDIA FILTER (For DOMESTIC WATER)

-

-

-

... More
23.2.1.3 : Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS: 2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/ bore, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer- in- charge, beyond 90 metre & upto 150 metre depth below ground level.All types of soil400 mm dia

200

-

-

... More
23.3.3 : Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in- Charge.200 mm nominal size dia

150

-

-

... More
23.8 : Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine /medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in- charge.

30

-

-

... More
23.12 : Development of tube well in accordance with IS: 2800 (Part I) and IS : 1189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc.by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer - in-charge.

60

-

-

... More
23.13.3 : Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia

2

-

-

... More
23.14.3 : Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS : 2800 ( part I), including ecessary bolts & nuts of required size complete.200 mm clamp

2

-

-

... More
od191494/2023_2024 : Supply, installation, testing & commissioning of vertical self-supporting Activated Carbon Filter (ACF) fabricated from FRP as per IS : 2825, ASMI code, complete with pressure gauges at inlet & outlet, sample cock, PVC face piping with ABS multiport valves and all accessories, with initial charge of filter media for Dual media filter with multi grade quartz sand & anthracite, lining inside with PP and FRP wounded outside, testing and commissioning complete as required & as specified as per directions of theEngineer-In-Chargewiththefollowing:Capacity : 125 LpmFiltration rate : 18-20 M³/M²/hrMax. operating pressure : 3.5 Kg/Sq.cm Test pressure : 5.5 Kg/Sq.cm

1

-

-

... More
od193650/2023_2024 : Supply, assembly, erection, testing, and commissioning of ozonator for a treated water complete in all respects.Flow rate 125 LPM with all the accessories required for proper functioning and treatement.<br>Ozonator<br>

1

-

-

... More
od194281/2023_2024 : "Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the systemto the satisfaction of the engineer in charge complete including providing and fixing wiring from control<br>junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions. To switch on the pumps (including raw water pumps (Domestic Water Treatment etc.) when the level of water in the supply water tank is low and to cut off the pump when the<br>level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low.To indicate 5 levels of water in all tanks through a control panel with LEDsTo start the pumps in a cyclic order.<br>The system shall be complete to ensure automatic quotation of<br>pump in accordance to water level in respective tanks.The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item."<br>

2

-

-

... More
od248155/2023_2024 : Supply installation testing and commissioning of Three phase 1.1KW/1.5HP, Centrifugal monobloc pump model GMC 1.525 ,50 mm suction and 40 mm delivery suitable for 6 to 26mtr head and 2.6 to 1.6 LPS discharge respectively (1 working+ 1 standby). <br>@ 6 meter head discharge will be 156 LPM<br>

1

-

-

... More
od248673/2023_2024 : Supply Installation testing and commissioning of Chlorine dosing pump of capacity 6LPH@ 4kg/cm2 with suitable capacity chemical holding tank and all related piping and control wiring works required for functioning.

1

-

-

... More
80 KLD Sewage Treatment Plant

-

-

-

... More
od222930/2023_2024 : Supply and installation of tube settler media ,hexagonal cheveron shaped of black 1.1mm Pvc

6

-

-

... More
od222931/2023_2024 : Supply and installation of mbbr media ,cool float random type of 20mm thickness.

8

-

-

... More
od222932/2023_2024 : Supply and installation of coarse bubble diffuser ,membrane tube type ,MOC-EPDM,80 mm dia and 5.0m3/hr capacity.

22

-

-

... More
od222933/2023_2024 : Supply and installation of rotary twin lobe air blower of 5 hp and rating of 110.0 m3/hr at 0.4kg/cm2.

2

-

-

... More
od222934/2023_2024 : Supply and installation of 1.0 hp/0.75KW/single phase submersible type sewage transfer pump of rating 8.0m3/hr @7.0 meters.

2

-

-

... More
od222935/2023_2024 : Supply and installation of net screen for sullage of moc-ss 304

1

-

-

... More
od222936/2023_2024 : Supply and installation of bar screen for sewage of moc ss304

1

-

-

... More
od222937/2023_2024 : Supply and installation of tod type energy meter for measuring electricity consumption

1

-

-

... More
od222938/2023_2024 : Supply ,erection and commissioning of plant with pipes, fittings, valves, cables, panel boards and related items

1

-

-

... More
od222939/2023_2024 : Supply and installation of ultra filtration system with a flow rate of 4000 ltrs/hr which includes 1 UF feed cum CIP pump and 1 back wash pump

1

-

-

... More
od222940/2023_2024 : Supply and installation of flow meter

1

-

-

... More
od222941/2023_2024 : Supply and installation of control panel which is a powder coated,CRCA,16 gauge sheet ,whether proof ,cubicle type, floor mounted and has MCB, contactor ,over load relay, push button, timer and energy meter.

1

-

-

... More
od222942/2023_2024 : Supply and installation of level controller which features a dry run preventer, high/low voltage protection, over load protection, timer function and auto/manual mode operations.

4

-

-

... More
od222943/2023_2024 : Supply and installation of alum dosing tank of capacity 50 ltrs

1

-

-

... More
od222944/2023_2024 : Supply and installation of lime dosing tank of capacity 50 ltrs

1

-

-

... More
od222945/2023_2024 : Supply and installation of electronic type 5LPH@4kg/cm2 chlorine dosing pump with 50 ltr tank

1

-

-

... More
od222946/2023_2024 : Supply and installation of hydro pure carbon filter of capacity 8.0m3/hr with a filter chamber size of 770 Dia X 2336 Ht of of composite FRP

1

-

-

... More
od222947/2023_2024 : Supply and installation of hydro pure sand filter of capacity 8.0m3/hr with a filter chamber of size 770 Dia X 2336 Ht of composite FRP.

1

-

-

... More
od222948/2023_2024 : Supply and installation of horizontal mono bloc filter feed pump with mechanical seal having 2.0HP/1.5 KW of rating 8.0m3/hr@24 meter head

3

-

-

... More
od222949/2023_2024 : Supply and installation of self priming ,coupled, non clog sludge recirculation pump with mechanical seal of 1 HP/0.75 KW with rating of 3.5 m3/hr@12.0 meter head.

1

-

-

... More
SANITARY FIXTURES AND INTERNAL PLUMBING

-

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

115

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

176

-

-

... More
17.10.1.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 200 mm

10

-

-

... More
od362401/2020_2021 : Providing, fixing, testing and commissioning of star white colour vitreous china below / over counter Oval Wash Basin / circular basin (Size 560 x 410 mm or as/architectural detail drawing) with CP brass waste assembly complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required.<br>

115

-

-

... More
od362439/2020_2021 : Supply,Installation,testing and commissioning of Two piece wall hung extended EWCs with seat cover and cistern with twin flush fittings (with 'p' trap of IS specification make and approved by the consultant) , MS / CI chair brackets, fischer bolts with CP bolts / nuts andflanges confirming to green building norms throught selection of low flow fix by 50% below the griha base rate, solid plastic seat and lid with heavy duty CP hinges and rubber buffers and flap etc. The work shall include cutting making of walls and floors etc. Notes: Necessary consumables like brass screws, CP extension nipple of approved make, dia and length, wooden plugs, white cement, sealants etc., required if any, shall be arranged by the contractor.

177

-

-

... More
od362445/2020_2021 : Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for wash basins.<br>32 mm dia<br>

115

-

-

... More
od362454/2020_2021 : Providing and fixing Disabled Toilet, Complete Set, including White Floor Mounted Water Closet, Plastic Cistern , Lid, Antimicrobial Seat Cover etc, Faucet/Tap with spactula lever and with 1no of Hinged Arm, 760mm. Long, 2nos of Grab Rail, each of 600mm. long, and with all necessary accessories and fixed with Brackets Expansion/Rawl sleeves, stainless steel/ brass bolts/screws, nuts, washers etc, including cutting and making good the walls and floors wherever required. including all as per manufacture's and to the approval of Engineer-in-charge.

11

-

-

... More
od362463/2020_2021 : Providing and fixing unplasticised PVC connection pipe with brass unions, 45 cm length.<br>15 mm dia nominal bore<br>

248

-

-

... More
od362471/2020_2021 : Providing and fixing CP concealead stop cock & flush cock with Regular Body of Concealed Stop Cock Suitable for 15 mm Pipe Line with<br>Protection Cap and fitting sleeve, operating lever and adjustable wall flange with seal.

176

-

-

... More
od362478/2020_2021 : Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws, complete in all respect.<br>

176

-

-

... More
od362490/2020_2021 : Providing and fixing of 15 mm C.P. Brass Sink Cock Mixer type with Swinging Spout (Wall Mounted Model) with Connecting Legs & Wall Flanges confirming to green building norms throught selection of low flow fix by 50% below the griha base rate as per the IS Standards

10

-

-

... More
od362510/2020_2021 : Providing & fixing, testing and commissioning of approved make & coloured urinal division plate of size 90 x320x720mm and fixed to wall by using CP brass screws etc. complete as per specifications.

100

-

-

... More
od362531/2020_2021 : Providing and fixing of 15 mm C.P. Brass pressomatic Pillar Cock with Auto Closing System confirming to green building norms throught selection of low flow fix by 50% below the griha base rate as per the IS Standards

116

-

-

... More
od362536/2020_2021 : Providing and fixing of 15 mm C.P. with Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook flow restrictor confirming to green building norms throught selection of low<br>flow fix by 50% below the griha base rate including all fittings and brackets of approved quality-

177

-

-

... More
od362585/2020_2021 : Providing and fixing CP brass bib cock of approved quality having low flow fixture unit confirming to green building norms throught selection of low flow fix by 50% below the griha base rate confirming to IS standards.

177

-

-

... More
od362616/2020_2021 : Supply, Installation, Testing and commissioning of wall hanging drinking online water cooler with bottle filler facility, made by stainless steel top and heavy duty galvanized steel frame. With cooling capacity, ADA Compliant, size 472 mm Depth X 447mm width, flexible bubbler guard , operated between 50 to 120 PSI, Chiller unit Suitable to R134a Refrigerant, Adjustable thermostat control, suitable for 220-230v/50-60 hz A/C Supply Complete with all accessories which include MD-CU29, which is an EPA registered antimicrobial copper that fights off microorganisms which include MRSA and e-coli. The water Fountain shall possess NSF-USA, GRIHA, TUV, and to be placed at different location of buidling. Agency has to execute all civil work for installing the Water Fountain/Online water cooler for proper functioning and aesthetic view as directed by the engineer-in-charge without any extra cost.<br>WITH 50 LPH RO System with 60 ltr HTP Storage tank. 50 Lph RO System including with, RAW WATER PUMP, MICRON FILTER, MEMBRANE HOUSING, Membrane Boosting Pump, RO Membranes, CONTROL INSTRUMENTS, SKID Hanging with Pressure tank of capacity of 60 Ltr.<br>

11

-

-

... More
17.69.1 : Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms

10

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

103

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

444

-

-

... More
17.28.1.1 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe32 mm dia

10

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

231

-

-

... More
od255776/2023_2024 : Providing & fixing 130 mm size Floor clean outs stainless steel as per the directions of engineer in charge with all the necessary fittings.

14

-

-

... More
SOIL, WASTE, RAIN WATER AND VENT PIPES

-

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

156

-

-

... More
50.18.8.7.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

40

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

735

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

110

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

90

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

95

-

-

... More
50.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall

160

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

779

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

30

-

-

... More
50.18.9.17.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall

240

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

6

-

-

... More
VALVES

-

-

-

... More
od363085/2020_2021 : Supply ,Fixing ,testing andComissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>32 mm dia.<br>

40

-

-

... More
od363322/2020_2021 : upply ,Fixing ,testing andComissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>50mm dia.<br>

22

-

-

... More
od363336/2020_2021 : Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required.<br>65 mm dia.<br>

8

-

-

... More
od363344/2020_2021 : Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required.<br>80 mm dia.<br>

4

-

-

... More
od195259/2023_2024 : Supply ,Fixing ,testing andComissioning of Ball valves of brass body nickel plated with brass ball ,lever operated and tested to 20KG/sq.cm<br>Ball Valve 20mm<br>

115

-

-

... More
Water supply - Ceiling suspended

-

-

-

... More
od77675/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessary clamps bolts and washers including making holes in the walls/beam and making it good after connection.32 mm dia pipes

120

-

-

... More
od77678/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 40 mm dia bore.

30

-

-

... More
od77679/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 50 mm dia pipes<br>

45

-

-

... More
od77680/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Ceiling suspended work with necessary support and clamps at 1mtr interval.32 mm dia pipes<br>

135

-

-

... More
od77681/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Ceiling suspended work with necessary support and clamps at 1mtr interval.25 mm dia pipes<br>

125

-

-

... More
Water supply Lines through shaft

-

-

-

... More
od78385/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessar clamps bolts and washers including making holes in the walls/beam and making it good after connection.<br>20 mm dia pipes<br>

45

-

-

... More
od78386/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessar clamps bolts and washers including making holes in the walls/beam and making it good after connection.25 mm dia pipes<br>

55

-

-

... More
od78387/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.20 mm dia pipes.

55

-

-

... More
od77678/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 40 mm dia bore.

60

-

-

... More
od77679/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 50 mm dia pipes<br>

120

-

-

... More
od194567/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors 65mm dia pipes

100

-

-

... More
od194574/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 25mm dia pipes

30

-

-

... More
Water supply Lines (through terrace)

-

-

-

... More
od78385/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessar clamps bolts and washers including making holes in the walls/beam and making it good after connection.<br>20 mm dia pipes<br>

79

-

-

... More
od78386/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessar clamps bolts and washers including making holes in the walls/beam and making it good after connection.25 mm dia pipes<br>

50

-

-

... More
od78387/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.20 mm dia pipes.

50

-

-

... More
od78467/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>32mm dia<br>

477

-

-

... More
od77675/2023_2024 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings for 10kg/sq.cm pressure, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Clamping of pipe lines in the support with neccessary clamps bolts and washers including making holes in the walls/beam and making it good after connection.32 mm dia pipes

50

-

-

... More
od194665/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.32 mm dia pipes<br>

40

-

-

... More
od194574/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 25mm dia pipes

70

-

-

... More
od194669/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors<br>65mm dia<br>

90

-

-

... More
od194680/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.40 mm dia pipes

65

-

-

... More
od194683/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.50 mm dia pipes

65

-

-

... More
od194684/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 40mm dia Pipes

130

-

-

... More
od194685/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-80 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 12kg/sq.cm pressure. making holes, including exposed in solid block mansory walls to required width and depth, making bores in walls, in ground by excavation and refilling wherever necessary,foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors. 50mm dia Pipes

100

-

-

... More
od195119/2023_2024 : Providing ,fixing,testing and commissioning of uPVC SCH-40 pipes confirming to ASTM D- 1785, including all fitting uPVC SCH-80 conforming to ASTM D 2467, like tees, elbows ,bends, unions, coupling, reducer tees, collars etc.The work shall include cutting jointing with solvent cement pressure testing the joints/pipeline for 10kg/sq.cm pressure. making holes, including chasing in solid block mansory walls to required width and depth, making bores in walls, foundation and RCC slabs, making good the walls and bores as applicable clearing the debris grouting of concealed pipes,MS hooks for fixing pipes and making good the walls and floors.65 mm dia pipes

147

-

-

... More
Water supply (wall/floor Concealed)

-

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

700

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

460

-

-

... More
water drainage Ceiling Suspended/Shaft

-

-

-

... More
od78470/2023_2024 : Supply,fixing,testing comissioning of multi inlet PVC floor trap with boss coupler suitable for ceiling suspended/sunken system with minimum 50mm water seal moulded ,with or with out vent arm jointing with rubber ring /solvent cement followed by application leakproof adhesive including making good the floors.<br>110mm dia<br>

262

-

-

... More
od195457/2023_2024 : Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT & UT.

262

-

-

... More
Supports

-

-

-

... More
od78562/2023_2024 : Supplying and fixing of approved make at site GI Slotted Rail Brackets,hangers,c clamp supports with necessary drilling holes to suit the insirtion of pipe clamps, deburring etc.,as per detailed drawing for supporting soil, waste & rain water pipes & water supply pipes in shafts and ceiling with suitable GI clamps,bolts,anchor bolts nuts & washers fixed on shaft walls/outer walls etc with 6mm / 8mm dia full threaded GI rod.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer.<br>

1100

-

-

... More
od195459/2023_2024 : Supply ,fixing ,testing and comissioning of PVC rain water head /khurra with grating, puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet including removable heavy duty PVC grating as per approved design .The quoted rate shall include necessary grouting the base of Khurras with aproved sealent complete. 150mmx150mm S.S grating

20

-

-

... More
VALVES PART 2

-

-

-

... More
od78567/2023_2024 : Supply ,fixing,testing and comissioning of the cast iron Y type strainer body with suitable flanged ,tested 15KG sqmm confirming IS 210 Gr Fg 200 with screen of SS304 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.<br>80 mm dia<br>

4

-

-

... More
od78570/2023_2024 : Supply ,fixing,testing and comissioning of the cast iron Y type strainer body with suitable flanged ,tested 15KG sqmm confirming IS 210 Gr Fg 200 with screen of SS304 standards and including a set of GI flanges as per BS 10 table including bolts and nuts,and Neoprane rubber gaskets etc.65 mm dia<br>

4

-

-

... More
od78571/2023_2024 : Supply, installation, testing and commissioning of 20mm. Air Release Valve gunmetal, conforming to IS 903:1993, having rubber ball and with 20mm. BSP threaded male inlet, including necessary accessories and connections.<br>20 mm air release valve<br>

14

-

-

... More
HT CABLE/TRANSFORMER

-

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

25

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

250

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

5

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

2

-

-

... More
RMU

-

-

-

... More
od174531/2023_2024 : "Supply testing & commissioning of 12 kV, SF6 Ring Main Unit IP 54 complete (Outdoor)( 2 Isolator+ 1Breakers+FRTU ) FBX-E /12-20/ CCT2+FRTU/one side extensible with Battery & Battery Charger. With rated operating voltage 11kV, rated lightining with stand voltage 75kV, rated power frequency with stand voltage 50kV 1min, Rated frequency: 50Hz, Rated peak current: 50kA, Rated short-time current:25kA, Rated short time1sec.Internal Arc withstadig 21kA 1sec. Motorised operation with Load break switch 630 A /High Performance VCB<br>400 A /Disconnector switch 630 A with a Bus bar of 630A and Breaking cpacity of 400A VCB fixed type with metering cubicle"<br>

1

-

-

... More
od255257/2023_2024 : Relocation of existing RMU from site to a safe position within the site itself after dismantling it from the current location without any damage as per the direction of engineer in charge, with necessary means and utlitities.

1

-

-

... More
HT PANEL BOARD

-

-

-

... More
od176504/2023_2024 : Supply installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of 14 SWG thick CRCA sheet fully compartmentalized complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number of 1250A VCB as incomer and three numbers of 400A VCB as outgoings as per the specification details below<br>Incoming:<br>1no:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection & metering.<br>Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. Metering compartment for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release, indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures andpowder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. <br>Out goings :<br>3 nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity Vaccum circuit breaker, dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuacy class for protection & metering.<br>Supply<br>

1

-

-

... More
TRANSFORMER

-

-

-

... More
od176748/2023_2024 : Supply of 1000kVA 11kV/433V indoor cast resin dry type USS (copper wound) with OLTC having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with offcircuit tapping +5% to -5% in steps of 2.5% by tap links, include separate winding temperature indicator for each phase and core in the Transformer, emergency off switch housed seperately outside. Transformer should have cable end box on HV side suitable for 3Cx185 sq.mm XLPE 11kV cable and suitable end box on LV side for connecting XLPE insulated PVC cables with all accessories, complete as required as per State electricity board, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/1985 with latest amendment etc complete with HT HRC fuses and output connected to 11KV seal off bushings to the transformer.<br>Supply, Installation, testing and commisioning<br>

1

-

-

... More
od176774/2023_2024 : Supply of 1000kVA 11kV/433V indoor cast resin dry type transformer (copper wound) with OLTC having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with offcircuit tapping +5% to -5% in steps of 2.5% by tap links, include separate winding temperature indicator for each phase and core in the Transformer, emergency off switch housed seperately outside. Transformer should have cable end box on HV side suitable for 3Cx185 sq.mm XLPE 11kV cable and suitable end box on LV side for connecting XLPE insulated PVC cables with all accessories, complete as required as per State electricity board, IE rules specifications. The transformer shall confirm to IS 2067/77, 11171/1985 with latest amendment etc complete with HT HRC fuses and output connected to 11KV seal off bushings to the transformer.<br>Supply, Installation, testing and commisioning<br>

1

-

-

... More
od176786/2023_2024 : Supply of following 11kV (E) grade XLPE insulated PVC sheathed compact circular armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard. 3cx300sq.mm XLPE Cable<br>

275

-

-

... More
BI-DIRECTIONAL HT TOD NET METER

-

-

-

... More
od176813/2023_2024 : Supply, Installation, testing & commissioning of 3 phase 4 wire according to IS14697-1999, CBIP-325, IS 159595A, class: 0.2S, TOD meter with RS485 port, LCD with backlit display of Electricity board approved make, in existing enclosures of outdoor metering cubicle including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant.

1

-

-

... More
DG SET AND ACCESSORIES

-

-

-

... More
od176823/2023_2024 : Supply installation testing and commissioning of 3phase, 415V, 0.8pf 50hz, 1500 RPM, air cooled DG set of the rating 500 kVA Diesel prime generating set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required. The battery charger of auxillary DC power supply unit, 24V, stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required. The Generator set shall have a integral type acoustic enclosure, engine and alternator as per latest MoEF/CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with EURO-II specifications, high performance class with double layer tap stator winding and dynamically balanced rotor (<2% harmonic factor) of standard fuel tank capacity, DG set shall be compatiable for automatic operation during KSEBL power failure. The DG set should include diesel day tank.

2

-

-

... More
od176830/2023_2024 : Supply installation testing and commissioning of 3phase, 415V, 0.8pf 50hz, 1500 RPM, air cooled DG set of the rating 750 kVA Diesel prime generating set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor etc with all accessories required. The battery charger of auxillary DC power supply unit, 24V, stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required. The Generator set shall have a integral type acoustic enclosure, engine and alternator as per latest MoEF/CPCB norms. Diesel engine shall be suitable for continuous operation of generator set and satisfies with EURO-II specifications, high performance class with double layer tap stator winding and dynamically balanced rotor (<2% harmonic factor) of standard fuel tank capacity, DG set shall be compatiable for automatic operation during KSEBL power failure. <br>

1

-

-

... More
EXHAUST PIPES

-

-

-

... More
od178012/2023_2024 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.. <br>250mm dia <br>

15

-

-

... More
od178027/2023_2024 : Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.. <br>200mm dia <br>

10

-

-

... More
od178030/2023_2024 : Supply & providing insulation for exhaust pipe with thermal insulation and providing aluminium cladding as per standards.<br>

25

-

-

... More
od179311/2023_2024 : DG set commisioning including Trial run of DG set for 6 hrs. on no-load and variable load condition and to record the parameters as per prescribed format as per manufacturer standards. Cost of consumable ( full tank fuel, oil, lube oil, etc.) to be borne by Contractor.<br>

2

-

-

... More
od180137/2023_2024 : "Providing, designing, welding, fixing & painting (two coats of primer & two coats of synthetic enamel paint of approved shade) with suitable sizes ISMC (100x75mm) angle iron / MS channels supports along with a wall / water piping support and free standing structure on roof of terrace along with lightening arrester / aviation light for DG fume pipes as per CPCB-II approved norms & complete as required. (support details shall be got approved before execution).<br><br>"<br>

3500

-

-

... More
LT CABLES &amp; CABLE TRAY

-

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

56

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

42

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

32

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

26

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

16

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

12

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

18

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

16

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

60

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

180

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

200

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

90

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

160

-

-

... More
od180294/2023_2024 : Supply of following size of 1.1 kv grade FRLS multicore aluminium / copper conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments.<br>3.5Core 400 Sqmm. Al armd Cable<br><br>

1680

-

-

... More
od185131/2023_2024 : "Supply of following size of 1.1 kv grade FRLS multicore copper conductor XLPE insulated<br>and XLPE sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments.<br>3.5Core 400 Sqmm. Cu armd Cable<br>"<br>

460

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

800

-

-

... More
4.6.8 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 62.5 mm depth X 2.0 mm thickness

120

-

-

... More
4.6.11 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness

90

-

-

... More
4.6.12 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.750 mm width X 62.5 mm depth X 2.0 mm thickness

120

-

-

... More
4.6.13 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.900 mm width X 62.5 mm depth X 2.0 mm thickness

50

-

-

... More
od255303/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>1c x 35 sq.mm Al Cable

30

-

-

... More
od255304/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>3c x 4 sq.mm Al Cable

150

-

-

... More
od255305/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>3c x 6 sq.mm Al Cable

30

-

-

... More
od255306/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>3cx10sq.mm Al Cable

90

-

-

... More
od255307/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>4cx4sq.mm Al Cable

800

-

-

... More
od255308/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>4cx6sq.mm Al Cable

390

-

-

... More
od255309/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>4cx10sq.mm Al Cable

1799

-

-

... More
od255310/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>4cx16sq.mm Al Cable

1725

-

-

... More
od255311/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>4cx25sq.mm Al Cable

270

-

-

... More
od255312/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>3.5cx35sq.mm Al Cable

810

-

-

... More
od255313/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date.<br>3.5cx50sq.mm Al Cable

550

-

-

... More
od255314/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx70sq.mm Al Cable

1880

-

-

... More
od255315/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx120sq.mm Al Cable

80

-

-

... More
od255316/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx185sq.mm Al Cable

210

-

-

... More
od255317/2023_2024 : Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. <br>3.5cx240sq.mm Al Cable

735

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

6

-

-

... More
od255346/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>1C x 35 Sq mm

30

-

-

... More
od255347/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>3C x 4 Sq mm

10

-

-

... More
od255348/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>3C x 6 Sq mm

4

-

-

... More
od255349/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>4C x 4 Sq mm

48

-

-

... More
od255350/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>4C x 6Sq mm

12

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

600

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

40

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

24

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

150

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

20

-

-

... More
5.18 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

850

-

-

... More
14.15.2 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)

750

-

-

... More
od185266/2023_2024 : "Supply installation and Comissioning of Decorative Postop 35W, Elegantly designed New generation IP 65 LED post-top, energy saving, environmental friendly, long life aesthetically designed <br>with good indirect symmetrical light distribution, die-cast aluminium landscape luminaire with high power <br>COB LED as light source. Operating temperature: -10°C to + 50°C, Operating voltage range: 140-270V, Average life L70B50: 50000 hours, High efficiency long life LED module with SMD , LED package mounted on MCPCB. Lumen, . Powered by built-in potted LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 415V AC), Over, Voltage protection, Surge Voltage protection :10 kv with SPD & other safety test as per IS 15885 Part-2/Sec 13,<br>CISPR 15. THD< 10%, PF>.95, IP 66, IK 09, Current= 0.175A, CCT 5700/4000K Havells Cat Ref: SPRING 6 or equivalent.

24

-

-

... More
od185267/2023_2024 : Supply installation and Commissioning of Aesthetically designed decorative 35W New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications,6500/4000K with THD<10. Havells CORAL LED or equivalent.

4

-

-

... More
od185269/2023_2024 : "Supply Installation and commissioning of 3.5mtr Aesthetically designed decorative hot dipped galvanized mild steel step pole with grey powder finish. Compatible for all post top range. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole with a base plate of 250mmx250mm, Base Plate thickness- 15 mm. Pole Thickness-76mm. Havells DECO pole or equivalent.

24

-

-

... More
od185270/2023_2024 : Supply installation and Comissioning of 9-10W LED Bollard Housing made up of aluminum pipe ( of OD 100mm) UV protected pure polyester powder coated black after phosphochromate treatment It consists of aluminum heat sink for effective thermal management, sturdiness & excellent corrosion resistant with Clear diffuser used for glare free uniform light distribution with IP 65 and IK 07 rating, weighting 3kg.Operating temperature: -10 °C to +45 °C. High efficiency long life LED module with SMD LED package mounted on MCPCB, LED Average life L70B50: 50000 hours, Lumen efficacy of LED >130 lm/W. Offered in 10W with CCT 3000K and CRI > 80, system Lumens 700lms, system lumen efficacy of 70lm/w. Powered by built-in, isolated, potted electronic LED driver in ABS housing with APFC (SMPS based constant current supply) Operating voltage range: 140 V - 270 V with Power Factor PF > 0.95, lower THD< 20%, Output Short / Open Circuit protection, Over Voltage protection, Surge Voltage protection 3.0KV(CM & DM) & other safety test as per IS 15885 Part-2/Sec 13..Mounting flange is made up of cast iron Fixed to ground by means of 2 nos. M10 bolts (max). Havells Cat Ref: Bamboo, or equivalent.

32

-

-

... More
od185759/2023_2024 : """Supply, Installation, Testing and Commissioning of exterior rated LED wall washing flood light luminaires<br>with color temperature (CCT) of 3000K and dedicated optics for architectural lighting. Luminaire has a<br>choice of architectural floodlighting optics with beam angles of 10°/25°/40°/60°/25X60°. Wattage not<br>exceeding 65-75W,with system lumen output of minimum 4200 lumen with all LED ON and operating<br>voltage of 100- 277V AC. Fixture should have Die-cast aluminium, powder-coated finish of RAL7040 with<br>Clear tempered glass lens and should have 54 no. of LED,s. Luminaire lifetime of 70,000 hours at 50<br>degree Centigrade @L70 and IP 66 & IK7 protection against weather. Fixture should have Height 364<br>mm±1% including surface mount base width 188 mm±1% , length 390 mm ±1% with constant locking<br>hinges for simple position control from various angles without special tools. The light fixture should have<br>Operating Temperature Range from -35ºC to 50ºC. LED make should be only Nichea, Osram, Cree,<br>Lumiled. <br>Work should be complete with necessary factory made weather proof cable, lenses, and<br>external power and data supply [if any], wiring, junction boxes, provisioning of power and data cabling<br>etc. as required. Suitable fixing arrangement , Foundation as required complete in all respect as per<br>direction of Engineer in Charge. Havells Cat ref: Ranger, Wipro, Philips""<br><br>"<br>

40

-

-

... More
od186328/2023_2024 : "Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC<br>sheathed armoured cable in existing trenches/ hume pipe/in ground as per IS : 7098:1988 with upto date amendments.<br>4c x 6 sq.mm<br>"<br>

250

-

-

... More
od186336/2023_2024 : "Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC<br>sheathed armoured cable in existing trenches/ hume pipe/in ground as per IS : 7098:1988 with upto date<br>amendments.<br>4c x 10 sq.mm<br>"<br><br>

375

-

-

... More
od186337/2023_2024 : "Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC<br>sheathed armoured cable in existing trenches/ hume pipe/in ground as per IS : 7098:1988 with upto date<br>amendments.<br>2c x 6 sq.mm<br>"<br>

2750

-

-

... More
od186338/2023_2024 : "Supplying and making end termination with brass compression gland and aluminium lugs for following<br>size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as<br>required.<br>4 X 6 sq. mm (25mm)<br>"<br>

20

-

-

... More
od255272/2023_2024 : Supply installation testing and commissioning of weatherproof outdoor type LED strip of 24 watts/per meter Flexible type with optimum brightness & uniformity of light for perfect cove lighting installed in a weather proof 2 inch linear profile with diffuser, The drive of 15/20 amps to be provided for every 5 to 6 mtrs, the drive should be enclosed properly considering the easiness of maintenance. This should include complete supply of material required for installing the aluminium profile and the LED strip as required for the commissioning.

251

-

-

... More
MAIN PANEL-R&D

-

-

-

... More
od186339/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic. The panel shall be of for 4A category meeting all requirements as per the standard.<br>This panel should include Bus bar mounting (4+0) Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 & UL 1449 4th edition. Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level <1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE .Short- Circuit Current rating (Isccr) – 85 kA/50 Hz . With in built Back up fuse upto 1600A. Total Response time <1 nano sec . Warranty: 10 years and 20 years life time cycle tested.Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.<br>Incomer -<br>EB Incomer - 1600A, 65kA Microprocessor based release FP ACB, with RS 485 /BMScompactability draw out type with 3 O/C & 1 E/F releases, stand by low set E/F relay with CT at neutral earthing strip - 1nos.<br>"DG Incomer - 1250A 65kA Microprocessor based release FP ACB with RS 485/BMS compactability, overload and E/F release and stand by low set earth fault relay using CT neutral earthing conductor -1nos.<br>"<br>"ATS - 1600A 4 Pole in open frame (without enclosure) The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing need to be provided .- 1 no<br> <br>"<br>1600A 433V, 50kA best conductivity extensible Cu TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement as shown in schematic<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average, Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 2Set<br><br>"<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 set<br>APFC relay module of 9 stages with 415V with necessary CT and accessories- 1 nos<br>Reverse current protection relay for gensets wit CT 630A/5A CL.1,15VA- 1 nos<br>Outgoings<br>1250A 50kA TP ACB Microprocessor based, with potential free contactor for BMS input- 1 nos.<br>500A 50kA TP MCCB Microprocessor based, with potential free contactor for BMS input- 4nos.<br>500 A TP Isolator - 1 no<br>Supply Installation testing & Commisioning<br>

1

-

-

... More
MAIN PANEL-CDC

-

-

-

... More
od186340/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic. The panel shall be of for 4A category meeting all requirements as per the standard.<br>This panel should include Bus bar mounting (4+0) Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 & UL 1449 4th edition. Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level <1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE .Short- Circuit Current rating (Isccr) – 85 kA/50 Hz . With in built Back up fuse upto 1600A. Total Response time <1 nano sec . Warranty: 10 years and 20 years life time cycle tested.Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.<br>Incomer -<br>EB Incomer - 1600A, 65kA Microprocessor based release FP ACB, with RS 485/BMS compactability draw out type with 3 O/C & 1 E/F releases, stand by low set E/F relay with CT at neutral earthing strip - 1nos.<br>"DG Incomer - 1250A 65kA Microprocessor based release FP ACB with RS 485/BMS compactability, overload and E/F release and stand by low set earth fault relay using CT neutral earthing conductor -1nos.<br>"<br>"ATS - 1600A 4 Pole in open frame (without enclosure) The switch shall have three possible operating positions (source one - center off –source two). The two sources can be isolated in the center off position. A position locking mechanism should also be provided. Phase loss sensing need to be provided .- 1 no<br> <br>"<br>1600A 433V, 50kA best conductivity extensible Cu TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement as shown in schematic<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 2Set<br><br>"<br>RYB phase indicating LED lamps with control fuses and switches - 2 set.<br>Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 set<br>APFC relay module of 9 stages with 415V with necessary CT and accessories- 1 nos<br>Reverse current protection relay for gensets wit CT 630A/5A CL.1,15VA- 1 nos<br>Outgoings<br>1250A 50kA TP ACB Microprocessor based, with potential free contactor for BMS input- 1 nos.<br>500A 50A TP MCCB Microprocessor based, with potential free contactor for BMS input- 3nos.<br>630A 50kA TP MCCB Microprocessor based, with potential free contactor for BMS input- 2 nos.<br> 800A,50KA TP MCCB Microprocessor based with potential free contractor for BMS input-1 <br>Supply Installation testing & Commisioning<br>

1

-

-

... More
DG SYNCHRONIZATION PANEL

-

-

-

... More
od186341/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>This panel should include Bus bar mounting (4+0) Surge Protection Device Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 & UL 1449 4th edition. Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level <1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE .Short- Circuit Current rating (Isccr) – 85 kA/50 Hz . With in built Back up fuse upto 1600A. Total Response time <1 nano sec . Warranty: 10 years and 20 years life time cycle tested.Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant.<br>Incomer:-1250A 50kA FP ACB Microprocessor based with thermal O/L, voltage controlledO/C relay,over voltage, under voltage, negative sequence, low set stand by earth fault relays and REF/Differential relay with fuel shut off facilities,with RS485 port for BMS input- 1 nos. 800A FP Microprocessor based ACB with overload and E/F release and stand by low set earth fault relay using CT in neutral earthing conductor.with RS485 port for BMS input- 2 nos.<br>1250A, 433V, 36 kA best conductivity Cu TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>630A FP nuetral contactor- 3nos<br>RYB phase indicating LED lamps with control fuses and switches - 3 set.<br>Bus bar mounting Surge Protection Device Class B & Class C/ Type 1 & Class 2 - 1 set<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average, Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 3 Set<br><br>"<br>PLC system with sychronization modules and control wiring for synchronizing and load sharing three DG sets including automatic start/stop with load sharing function. The system should comply latest technology.<br>1250A 50kA FP ACB EDO type as Bus coupler without protection - 1 nos.1600A 50kA FP ACB EDO type as Bus coupler without protection - 1 nos<br>Outgoings<br>1250A 50kA TP ACB Microprocessor based, with potential free contactor for BMS input- 2 nos.<br>800A 50kA TP ACB Microprocessor based, with potential free contactor for BMS input- 2 nos.<br>Supply, Installation, Testing & Commissioning<br>

1

-

-

... More
UPS PANEL R& D Block

-

-

-

... More
od186342/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 100 A FP isolator-1 no<br>100A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 63A TP MCB -5 nos<br>Supply,Installation, testing & Commissioning<br>63A 100MA FP RCBO -5

1

-

-

... More
LIFT PANEL R&D Block

-

-

-

... More
od186343/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 120A TPN Isolator<br>120A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br>63/300mA FP RCCB+MCB-3 nos and additional settings for BMS compactability<br>16A DP MCB -1 no<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
GROUND FLOOR PANEL -CDC Block

-

-

-

... More
od186344/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 125A 25kA FP Thermal magnetic MCCB-1 no<br>125A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average, Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 63A TP MCB -1 nos<br> 80A TP MCB -2 nos<br>Supply, Installation, testing & Commissioning<br>

1

-

-

... More
METERING PANEL (Type-1)

-

-

-

... More
od186345/2023_2024 : Fabrication, supply, erection, testing and commissioning of type tested cubicle type(panel and all switch gears should be type tested and certification should be obtained), dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Incomers -<br>125A, 16kA FP MCCB -1No.<br>125 TPN , 16kA best conductivity Aluminium TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>Consumer service each unit consisting of 1No. 63A FP MCB, 63 A fuse unit, and one number three phase CT operated dual source energy meter for meteirng the EB and DG power seperately with all control wiring and the meter shall be tested and approval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc with BMS compatibility (2 nos of CT to be provided for dual source energy meter) -7 Set<br>Compartment - II<br>Control signal from the DG panel<br>32A, 16 kA best conductivity Al SPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Outgoings - <br>DG Control signal to each dual soure energy meter- 7nos<br>Supply Installation, testing and commisioning<br>

1

-

-

... More
METERING PANEL (Type-2)

-

-

-

... More
od186605/2023_2024 : Fabrication, supply, erection, testing and commissioning of type tested cubicle type(panel and all switch gears should be type tested and certification should be obtained), dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>Incomers -<br>250A,25kA FP Thermal magnetic MCCB -1No.<br>250A, 25kA best conductivity Aluminium TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Outgoing<br>Consumer service each unit consisting of 1No. 63A TP MCB, 63 A fuse unit, and one number three phase CT operated dual source energy meter for meteirng the EB and DG power seperately with all control wiring and the meter shall be tested and aproval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc (2 nos of CT to be provided for dual source ennergy meter) -8 Set,<br> Consumer service each unit consisting of 1No. 160A TP MCB, 160 A fuse unit, and one number three phase CT operated dual source energy meter for meteirng the EB and DG power seperately with all control wiring and the meter shall be tested and approval shall be taken from KSEBL including all accessories required for complete installation and its inter connections etc (2 nos of CT to be provided for dual source ennergy meter) -1 Set<br>Compartment - II<br>Control signal from the DG panel<br>32A, 16 kA best conductivity Al SPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Outgoings - 63A TP MCB <br>DG Control signal to each dual source energy meter- 9nos<br>Supply Installation, testing and commisioning<br>

5

-

-

... More
LIFT PANEL CDC Block

-

-

-

... More
od186617/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 120A FP Isolator<br>120A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br>63/300mA FP RCCB+MCB-4 nos<br>16A DP MCB -1 no<br>Supply Installation, testing and commisioning<br>

1

-

-

... More
LIGTHING PANEL

-

-

-

... More
od186623/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 63A FP ISOLATOR - 1 no<br>63A FP contactor - 1no<br>Digital Timer programmable switch with &D,24H programmable switch and consumption:- 1 channel max 4VA. Memory upto 56 switching operations with lithium battery to ensure back uptime and program. The dimension should not exceed 5 modules.<br>63A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average, Instantaneous Frequency, Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br>25A TP MCB - 1nos.<br>25A DP MCB - 1nos.<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC PANEL 1 R&D

-

-

-

... More
od186682/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 630 A 36KA FP MCCB -1 no<br>630A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 250A TP Thermal magnetic based MCCB -1 nos<br> 200A TP Thermal magnetic based MCCB with BMS compatibility -2 nos<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC PANEL 2 R&D

-

-

-

... More
od186758/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 630 A 36 KA FP MCCB-1 no<br>630A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 200A TP Thermal magnetic MCCB -3 nos and one dummy spare compartment<br>Supply, Installation, testing & Commissioning<br>

1

-

-

... More
HVAC SUB PANEL 1 R&D

-

-

-

... More
od186788/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 250 A 25 KA FP MCCB-1 no<br>250A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A TP Thermal magnetic based MCCB -4 nos<br> 80A TP Thermal magnetic based MCCB -2nos<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC SUB PANEL 2

-

-

-

... More
od186805/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 200A 25KA FP MCCB-1 no<br>200A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 63A TP MCB -8nos<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC SUB PANEL 3&6

-

-

-

... More
od186838/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 200 A 25KA FP MCCB-1 no<br>200A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A TP Thermal magnetic MCCB -3 nos<br> 80A TP Thermal magnetic MCCB -2 nos and one dummy compartment as spare<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
HVAC SUB PANEL 4&5

-

-

-

... More
od186985/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 200 A 25KA FP MCCB-1 no<br>200A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A TP Thermal magnetic MCCB -3 nos<br> 80A TP Thermal magnetic MCCB -1 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
HVAC PANEL 1 CDC BLOCK

-

-

-

... More
od187991/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 800 A 50 KA FP Microprocessor based ACB-1 no<br>800 A, 433V, 50 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br>Outgoings<br> 320A 36kA TP Thermal magnetic based MCCB -2 nos<br> 200A 36kA TP Thermal magnetic MCCB -1 nos<br>Supply, Installation, testing & Commissioning<br><br><br>

1

-

-

... More
HVAC PANEL 2 CDC BLOCK

-

-

-

... More
od188583/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 630 A FP MCCB-1 no<br>630A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 320A 36kA Thermal magnetic based TP MCCB -1 nos<br> 200A 25kA Thermal magnetic based TP MCCB -2 nos and summy compartment for spare<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC PANEL 3 CDC BLOCK

-

-

-

... More
od188583/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 630 A FP MCCB-1 no<br>630A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 320A 36kA Thermal magnetic based TP MCCB -1 nos<br> 200A 25kA Thermal magnetic based TP MCCB -2 nos and summy compartment for spare<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC SUB PANEL 1&2 CDC

-

-

-

... More
od190017/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 320 A 36kA FP MCCB-1 no<br>320A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A 16kA TP Thermal magnetic based MCCB -7 nos<br> 80A 16kA TP Thermal magnetic based MCCB -1 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
HVAC SUB PANEL 3&5 CDC BLOCK

-

-

-

... More
od190774/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 200 A 25kA FP MCCB-1 no<br>200A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A 16kA Thermal magnetic based TP MCCB -5 nos<br> 63A 16kA TP Thermal magnetic based MCCB -1 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
HVAC SUB PANEL 4 CDC BLOCK

-

-

-

... More
od190918/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 320 A 36kA FP MCCB 1 no<br>320A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A 16kA TP Thermal magnetic based MCCB -5 nos<br> 80A 16kA TP Thermal magnetic based MCCB -1 nos<br> 63A 16kA TP Thermal magnetic based MCCB -3 nos<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
HVAC SUB PANEL 6&9 CDC BLOCK

-

-

-

... More
od191161/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 200 A 25kA FP MCCB 1 no<br>200A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 40A TP MCB -8 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
HVAC SUB PANEL 7&8 CDC BLOCK

-

-

-

... More
od191174/2023_2024 : Supply,Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 320 A 36kA FP MCCB -1 no<br>320A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br> 100A 16kA TP Thermal magnetic based MCCB -6 nos<br> 80A 16kA TP Thermal magnetic based MCCB -2 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
UTILITY PANEL

-

-

-

... More
od191272/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 500A FP Isolator,- 1 nos.<br>500A, 433V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br>100A 25 kA TP MCCB thermal magnetic based -3 no<br>250A 25 kA TP Thermal magnetic based MCCB-1no<br>63A TP Isolator- 2 nos.and 2 nos dummy compartment for spare<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
od255275/2023_2024 : Supply, Installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.<br>Incomer - 160 A 25kA FP Thermal magnetic based MCCB-1 no.<br>160A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br> 40A TP MCB -2 nos<br> 80A TP MCB -1 nos<br>32A TP MCB -6 nos<br>25A TP MCB -1 nos<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
PUMP PANEL R&D BLOCK

-

-

-

... More
od191293/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 100A 25 kA FP MCCB thermal magnetic based.<br>100A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>"96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br><br>"<br>Outgoings<br>40A TP MCB - 2 nos.<br>25A TP MCB - 1 nos.<br>16A TP MCB - 1 nos.<br>40A change over switch - 1nos<br>25A change over switch -1nos<br>16A change over switch - 1nos<br>DOL starters for (2 nos 1.5HP Pump, 2 nos 5HP pump)<br>Star Delta starters for (2 nos 7.5HP Pump,1 nos 7 HP bore well pump)<br><br><br>"<br>Supply,Installation, testing & Commissioning<br>

1

-

-

... More
250 kVAr APFC PANEL

-

-

-

... More
od191340/2023_2024 : Supply,erection, testing and commissioning of 16 SWG freestanding indoor cubicle made of CRCA sheet steel with seven tank process. Automatic power factor control panel of rating 250kVAr  with 7% Block Reactor & tuned capacitors using capacitor switching. By using Microprocessor based relay operated controller with minimum 8 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. 500A  35kA 3P MCCB with  high rupturing capacity and in built overload and short circuit releases as per specifications  as incomer, , housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes and required rating of capacitor shall be directly connected to the main bus for no load compensation. The capacitors shall be with U.L listed pressure sesitive interrupter, inside hermctically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage <50Vwithin one min of de-energisation.. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control. <br>Metering : Digital Ammeter with  CT -3Nos , Digital Voltmeter with selector- 1No ,  R Y B Indication with control fuse -1Set, Automanual selector switch- 1No , Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge/consultant. <br> Supply Installation, testing and commisioning<br>

1

-

-

... More
200 kVAr APFC PANEL

-

-

-

... More
od191378/2023_2024 : Supply,erection, testing and commissioning of 16 SWG freestanding indoor cubicle made of CRCA sheet steel with seven tank process. Automatic power factor control panel of rating 200kVAr  with 7% Block Reactor & tuned capacitors using capacitor swtiching. By using Microprocessor based relay operated controller with minimum 8 stage which should be capable to switch on the required kVAr for compensation based on cyclic switching. 500A  35kA 3P MCCB with  high rupturing capacity and in built overload and short circuit releases as per specifications  as incomer, , housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes and required rating of capacitor shall be directly connected to the main bus for no load compensation. The capacitors shall be with U.L listed pressure sesitive interrupter, inside hermctically sealed metal cans. with terminal bushings to withstand 10 KV AC to ground with treated terminals and capacitor cells shall be provided with discharge resistors to reduce residual voltage <50Vwithin one min of de-energisation.. All controls shall be mounted on enclosure door with door interlocks. Heavy duty capacitor duty contactors with high rupturing MCB shall be used for individual stage control. <br>Metering : Digital Ammeter with  CT -3Nos , Digital Voltmeter with selector- 1No ,  R Y B Indication with control fuse -1Set, Automanual selector switch- 1No , Forced cooling using fans, APFC relay - 1 no. including all connections and interconnections, all accesories as required for complete installation as instructed by engineer in charge/consultant. <br> Supply Installation, testing and commisioning<br>

1

-

-

... More
EARTHING

-

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

21

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

500

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

350

-

-

... More
od191729/2023_2024 : Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100 microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.

60

-

-

... More
od191820/2023_2024 : "Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 40x40 for Lightning Protection application. Earth stud with connecting accessories inside the concrete - ( Earth stud + Bonding Clamp + Connecting Point + Green cover). Govt approved Indian labs test certificate required. Govt approved Indian labs test certificate required.

38

-

-

... More
od192490/2023_2024 : "Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm<br>Meets the requirement (IS/IEC 62305)<br>Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal.<br>Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.<br>Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.<br>3 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories

12

-

-

... More
od192524/2023_2024 : "Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm<br>Meets the requirement (IS/IEC 62305)<br>Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal.<br>Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.<br>Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. <br>4 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories<br>

18

-

-

... More
od192529/2023_2024 : "Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. <br>Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters<br>

600

-

-

... More
od192533/2023_2024 : "Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. "Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters<br><br>

130

-

-

... More
od192609/2023_2024 : Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters

150

-

-

... More
od192621/2023_2024 : Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece with Connector: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required.

140

-

-

... More
od192631/2023_2024 : Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 170mm. Govt approved Indian labs test certificate required.

4

-

-

... More
od253037/2023_2024 : Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required.

9

-

-

... More
od253038/2023_2024 : Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305 for ring earthing & Exothermic Weld Joints for 20mm rod to 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305 for down conductor to pit joints. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required.

22

-

-

... More
SOLAR PLANT EQUIPMENT AND ACCESSORIES

-

-

-

... More
od248156/2023_2024 : Supply, installation, testing, commissioning of Roof mounted Grid Interactive Solar Photo voltaic station of total capacity 100kWP with remote monitoring facility consists of following items:-<br> 540Wp monocrystalline, PERC IP68 rated junction box & connectors Solar photo voltaic panels complying with IEC standards.Quantity of PV modules to be minimum of 240 nos<br>

2

-

-

... More
od248442/2023_2024 : Supply installation testing and commissioning of Three phase string inverter with MPPT technology of 100kW AC output power comprising minimum number of 6 MPPT inputs with minimum 4 strings/MMPT, DC side disconnect device, surge arresters type II, AC switch, terminal blocks. Operating DC voltage of 320V‐800V, IP 66 enclosure. The Inverter shall comply with IEC standards<br>

2

-

-

... More
od248560/2023_2024 : Supply and Installation of DCDB having enclosure with openable door made of Thermoplastic Glass Fiber Reinforced Polycarbonate (PC) with an Ingress Protection IP 65 in accordance with IEC 60529. consists DC switches, fuses, fuse holder, surge protection devices, terminal blocks, connectors etc of suitable rating and quantities<br>

2

-

-

... More
od248678/2023_2024 : Supply installation testing and commissioning of AC distribution board consists of powder coated metallic enclosure of 16 SWG thickness, IP 66, consists of busbars, MCCBs, AC switches, surge protection devices, terminal blocks, connectors etc of suitable rating and quantities complete as required for the commissioning.

2

-

-

... More
od248728/2023_2024 : Supply and laying of UV stabilized, halogen free, flame retardant, tinned copper 1.5 kV nominal voltage, DC flexible solar cable of minimum 4 sq mm including cable lug and glands, earth tag etc.

2000

-

-

... More
od248891/2023_2024 : Supply and fabrication of PV module mounting structural work on the existing building at a height of 2.5m from terrace level. The work includes frame work of suitable dimensions including cutting, welding, applying steel primer and two coats of enamel paint. Grating, frames, guard bar, ladder, railing brackets, and similar works to be included.<br>Structural design for PV station to be done by the contractor in suitable material and approval to be obtained as mentioned in the conditions of contract.

7800

-

-

... More
od248946/2023_2024 : Supply installation testing and commissioning of Net metering facility with all the testing from the KSEB side and the paperwork for installing the meter to establish energy export/import from PV station to the KSEB grid.

1

-

-

... More
Metering Panel Type-3 R&D

-

-

-

... More
od255176/2023_2024 : Fabrication, supply, erection, testing and commissioning of type tested cubicle type(panel and all switch gears should be type tested and certification should be obtained), dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable.Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. <br>100A,16kA FP Thermal Magnetic based MCCB -1No.<br>100A, 16kA best conductivity Aluminium TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>Consumer service each unit consisting of 1No. 63A FP MCB, 63 A fuse unit, and one number three phase CT operated dual source energy meter for meteirng the EB and DG power seperately with all control wiring and the meter shall be tested and aproval shall be taken from KSEBL including all accessories required for complete installation and its inter connections with BMS compatibility etc (2 nos of CT to be provided for dual source energy meter) -4 Set<br>Compartment - II<br>Control signal from the DG panel<br>32A, 16 kA best conductivity Al SPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Outgoings - <br>DG Control signal to each dual soure energy meter- 4nos<br>Supply Installation, testing and commissioning<br>

4

-

-

... More
STP Room Panels

-

-

-

... More
od255189/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.<br>Incomer - 100A 16 kA FP Thermal magnetic based MCCB - 1 nos.<br>100A, 433V, 16 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>16A TP MCB -10 nos<br>Supply,Installation, testing & Commissioning<br>

2

-

-

... More
od255190/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic<br>Incomer - 100A FP Isolator.<br>100A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br>40A TP MCB - 1 nos.<br>25A TP MCB - 3 nos.<br>16A TP MCB - 2 nos.<br>40A change over switch - 1nos<br>25A change over switch - 3nos<br>16A change over switch - 2nos<br>DOL starters for (4 nos 1HP Pump,42 nos 3HP pump, and 2 nos 5HP pump)<br>Star Delta starters for (2 nos 7.5 HP).<br>Supply,Installation, testing & Commissioning<br><br><br>

1

-

-

... More
od255191/2023_2024 : Supply, installation, testing & commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet, fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel etc including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable as per general specifications and drawings complete with all interconnections, powder coating , control wiring etc… as per IS,KSEB / Inspectorate Regulations and General conditions/ Technical Specifications. Panel shall be quoted with all interconnection and internal wiring and cabling as shown in the schematic.<br>Incomer - 250A 25 kA FP MCCB Thermal Magnetic based- 1 nos.<br>250A, 433V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. <br>Surge Protection Device Class B+C/ Type 1+2 - 1 set<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>96x96 mm size multifunction meter as per IEC 62053-21 for class 1 having multiline LED display with following parameters -Phase wise instantaneous and Average values – Voltage, Current, Power Factor, Phase wise instantaneous and Average values – Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, 4. PF for 3 phases and average,Instantaneous Frequency,Total Harmonics Distortion – Phase wise Voltage and Phase wise Current, Min and max of VLL, VLN, A, F, W, VA, VAr, PF with date and time stamp,Battery backed RTC with 2 years of power down time, Demand calculations based on W, VA, VAr, 10. Demand sync – Sliding window or block window site selectable, Demand interval: 5 to 30 min, Individual harmonics upto 15th order for voltage and current, Percentage Unbalance – Voltage and Current, Cumulative Run Hours, Sampling rate of 64 samples / cycle, Measuring circuit burden should be lesser than 0.2 VA, Aux burden < 5VA, Meter shall be suitable for CT secondary 1A /5A including CTs, site programmable CT & PT ratio, Meters shall have RS485 port with MODBUS RTU protocol, with IP 51 protection from front end preventing dust and moisture entry, meters shall be integrated with EMS - 1 Set<br>100A 16 kA TP MCCB thermal magnetic based -3 nos<br>63A 16 kA TP MCCB thermal magnetic based -1 no<br>One no Dummy compartment as spare.<br>Supply & Installation

1

-

-

... More
Car Charger

-

-

-

... More
od266992/2023_2024 : Supply installation testing and commissioning of IEC 60309 Socket to Wizz Basic Charger Convertor with all accessories required for commissioning.

3

-

-

... More
od266993/2023_2024 : Supplying installation testing and commissioning of 3 X 3.3 KW AC Bharat AC001 EV Charger with IEC 60309 Socket complete required for connection and commissioning with RFID, Bluetooth, ethernet, WIFI connectivity.

1

-

-

... More
od266994/2023_2024 : Supply installation testing and commissioning of 30kW DC wall box with single CCS2 gun, cable 5 meters (from Charger to EV), with metallic cable hanger, 415VAC, 50Hz, 3ɸ, 5Wire (L1, L2, L3, N & PE), with RFID, Bluetooth, ethernet, WIFI connectivity

1

-

-

... More
POINT WIRING

-

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

345

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

254

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

508

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

254

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

75

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

370

-

-

... More
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

514

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

7500

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

4500

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

450

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

650

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

450

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

180

-

-

... More
15.3 : Supplying, installation, testing and commissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.6 mtr and for 5m x 20 m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.

188

-

-

... More
DISTRIBUTION BOARD

-

-

-

... More
od11972/2021_2022 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)<br>6 way (4 +18), Double doo for comon area

35

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1300

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

75

-

-

... More
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door

7

-

-

... More
od81263/2023_2024 : Supply, installation, testing and commisioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and iterconnections as required and as instructed by engineer in charge/consultant. <br>40A TP MCB<br>

15

-

-

... More
od81479/2023_2024 : Supplying,fixing, testing and commisioning following way, vertical type three pole and neutral, sheet steel, MCB flexi row distribution board, conforming to IEC 61439-1&3, IS 8623-1, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, insulated busbar & shrouded neutral bars, with provision for FP Isolator as incomer, DP RCBO as sub incomer and MCB outgoings. The DB shall have phase segmentation and seperation between incomer & outgoings, with wire set for interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). DB shall be IP 43 rated double door with IK 09 protection fabricated with CRCA sheet steel, RAL 9003, powder coated with neutral bars with shrouds, earth bars, sticking saddles, cement spill protector, cable ties, blanking plates and circuit identification labels with provision for mounting modular devices as per requirement (But without MCB/RCCB/ Isolator). Incomer shall be 14 modules with provision for adding direct multifunction meter for EMS integration and surge arrestors.<br>3 Tire 36 module DB<br>

16

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door

3

-

-

... More
2.5.3 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door

3

-

-

... More
2.5.4 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4+12), Double door

1

-

-

... More
2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required100 Amp, 30 KA 4 Pole

4

-

-

... More
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required125 Amp, 36 KA

1

-

-

... More
2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

54

-

-

... More
od255329/2023_2024 : Supply, installation, testing and commissioning of following rating MCCB, 16kA as per IS/IEC 60947-2 in the existing VDB including all connections and inter connections as required and as instructed by engineer in charge/consultant.<br>63A FP MCCB

6

-

-

... More
od255330/2023_2024 : Supply, installation, testing and commissioning of following rating TP C curve MCB, 10kA as per IS/IEC 60898-12002 in the existing MCB VDB including all connections and inter connections as required and as instructed by engineer in charge/consultant.<br>6- 32A TP MCB<br>

58

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

16

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

55

-

-

... More
90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.

10

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

1250

-

-

... More
od361225/2020_2021 : Supplying installation testing and commissioning of 5 star rated , BEE certified 26W, ceiling fan with BLDC motor, with super enamelled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length down rod all accessories required for complete installation

3

-

-

... More
od361229/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply of 15W, SURFACE Mounted LED Down Light,polycarbonate Cover with pressure die cast aluminum housing, withopal PC diffuser for uniform low glare light and PC reflector to enhance product light output,System Lumen of 1500Lm, CRI>80, 5700K, THD<10%, PF>0.95, IP20, IK03, Life class of 50,000 hrs @ L70,Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ,Internal Surge Protection:2.5 KV; Protection : Reverse Polarity, Open & Short Circuit,driver safety requirement standards :is 15885-2-13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source,fixture to be BIS certified.

248

-

-

... More
od361231/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply of 18-20W integrated batten , Made of Aluminum Extrusion with housing part in Anodized finish & diffuser part in reeded opal finish. Lumen Output of 1980 lumens with System efficacy of > 110lm/W .CRI >80, Color temperature 6500K, THD <15% and PF>0.95, IP20 . Life class of 35,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV; Protection : Reverse Polarity, Open & Short Circuit.

156

-

-

... More
od361233/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply Installation and Comissioning of recessed mounted 6-7W Round Shape Downlighter with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling. pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integral electronic low THD (<10%) LED driver.High efficiency long life LED package in integral module with lumen efficacy of >110 lm/W .Powered by an integrated driver, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. System Lumen Output 1100lumens.CRI >80, Color temperature 5700K, THD <10% and EMI/EMC Compliance, PF >0.95, IP20, IK03. Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3.5 KV; Protection : Reverse Polarity, Open & Short Circuit.

281

-

-

... More
od361235/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply of surface mounted 10W Bulkhead with high performance LEDs, suitable for surface mounting with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integral electronic low THD (<10%) LED driver.High efficiency long life LED package in integral module with lumen efficacy of >110 lm/W .Powered by an integrated driver, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. System Lumen Output 1300lumens.CRI >80, Color temperature 5700K, THD <10% and EMI/EMC Compliance, PF >0.95, IP20, IK03. Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3.5 KV; Protection : Reverse Polarity, Open & Short Circuit.

57

-

-

... More
od361279/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply of recessed mounted 18W Round Shape Downlighter with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling. pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integral electronic low THD (<10%) LED driver.High efficiency long life LED package in integral module with lumen efficacy of >110 lm/W .Powered by an integrated driver, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. Lumen Output of 1700lumens.CRI >80, Color temperature 5700K, EMI/EMC Compliance,PF >0.95,IP20,IK03.Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3.5 KV; Protection : Reverse Polarity, Open & Short Circuit.

71

-

-

... More
od361282/2020_2021 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.<br>Supply of 28W 2x2 Panel recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling.CRCA powder coated white after phosphochromate treatment.High efficiency long life LED package in integral module with lumen efficacy of >120 lm/W .Powered by an independent Isolated, SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. Minimum System Lumen Output of 4200 lumens.CRI >80, Color temperature 5700K, UGR<19, THD <5% and PF >0.95, IP20, IK03. Life class of 50,000 hrs @ L70, EMI/EMC Complied, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3.5 KV; Protection : Reverse Polarity, Open & Short Circuit.

71

-

-

... More
od267742/2023_2024 : Supply, installation, testing and commissioning of 5 star rated , BEE certified wall fan of 450 mm sweep with BLDC motor, including all accessories as required for complete installation.

6

-

-

... More
od94902/2024_2025 : Supply, installation, testing and commissioning of Modern Light Fixture for double height area chandlier - 4ft (Dia) X 12ft (Height) Gold Plate.Product Dimensions-‎122L x 122W x 365H Centimeters,indoor,‎Semi Flush Mount,‎Energy Efficient,LED type,‎Polished,‎Metal,‎warm white,‎Round,gold colour, as per the drawing approved by Engineer in Charge.

1

-

-

... More
od95254/2024_2025 : Supply of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connectors, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required. Track Lights 24W<br>Beam Angle36° Body Color White, Black Color Rendering Index (CRI)≥80 Color Temperature (CCT) 4000K (NWH) Input Voltage AC 100-300 V IP RatingIP20 LED Light Source COB Luminaire Body & FinishDie-cast Al. body with High efficiency Aluminium Reflector Optics Luminous Efficiency 105 Lm/W<br>Power Consumption 24 w±5% Power Factor≥0.95 Rated Life 40000 Hours<br>Rated Luminous Flux 2520 Lm Working Temperature 0°c to + 50°c as per drawing and details approved by Engineer in charge.

4

-

-

... More
od95322/2024_2025 : Supply, installation, testing and commissioning of designer reception light 55W,ironplus silica gel, white modern chandlier 3 tier .The Top Ring Diameter is 60 cm The Middle Ring Diameter Is 40 CM And The Lowest Ring Diameter Is 20 Cm.High quality material and manufacturing for long life time performance New style and design innovated by expert designer<br>Light Color is Warm White 3000K. Including all other accessories, of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.

1

-

-

... More
UPS SYSTEM

-

-

-

... More
od81808/2023_2024 : Supply, installation, and commissioning of 60kw power cabinet 60kw UPS with min 9 modules Three phase in and out with vertical & horizontal paralleling compatibility orindependent phase management with indoor (IP21), with surge protection system Input pf>0.99, input THDi <3 % without use of any external filters, double conversion technologywith input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Threephase, It shall be 100% generator compatible, with Efficiency > 94% and output power factor<br>unity ( 60kVA= 60kW), Eco mode Efficiency 98% and including all accessories etc as required.The acoustic noise at 1m of the system should be <55dB.The system shall comply to IEC /EN62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, ISO 14025 PEP or equivalent Certificate andrelevant IS standards. The system shall be true online double - conversion DSP based UPS system and UPS shall be with automatic bypass built-in. The system shall have IGBT rectifierand inverter. warranty 2 years for UPS and batteries. <br>15 min backup battery @ 60kw .8 PF load (SMF battery of reputed approved make exide/quanta), having dual battery bank with Min VAH 15600x 2 per ups,(2 string) 12v65ahx40 batteries)<br>

1

-

-

... More
od255335/2023_2024 : Supply, installation, and commissioning of 20kw Modular UPS with Three phase in and out with vertical & horizontal paralleling compatibility or independent phase management with indoor (IP21), with surge protection system Input pf>0.99, input THDi <3 % without use of any external filters, double conversion technology with input voltage range 320-460 @ full load, 50Hz Three Phase, output 400V, 50Hz Three phase, It shall be 100% generator compatible, with Efficiency > 94% and output power factor unity ( 60kVA= 60kW), Eco mode Efficiency 98% and including all accessories etc as required.The acoustic noise at 1m of the system should be <55dB.The system shall comply to IEC /EN62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, ISO 14025 PEP or equivalent Certificate and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and UPS shall be with automatic bypass built-in. The system shall have IGBT rectifier and inverter. warranty 2 years for UPS and batteries.<br>15 min backup battery @ 20kVA .8 PF load (SMF battery of reputed approved make exide/quanta), having dual battery bank with Min VAH 10080(12v45ahx20 batteries)<br><br>

1

-

-

... More
RISING MAINS & TAP OFF BOXES, END FEED UNIT PANELS

-

-

-

... More
3.11.5 : Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required630 amps 50KA SC for 1 sec

1

-

-

... More
3.11.8 : Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required1250 amps 50KA SC for 1 sec

1

-

-

... More
3.13.3 : Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required630 amps 50 KA SC for 1 sec

10

-

-

... More
3.13.6 : Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required1250 amps 50 KA SC for 1 sec

50

-

-

... More
3.2.3 : Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.63 amps TPN

4

-

-

... More
3.2.4 : Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.100 amps TPN

10

-

-

... More
3.2.5 : Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.200 amps TPN

2

-

-

... More
3.12.3 : Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required250 A, (lsc=30 kA for 1 second)

5

-

-

... More
3.12.6 : Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required630 amps 50KA SC for 1 sec

2

-

-

... More
2.2.16 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required250 Amp, 36 KA

5

-

-

... More
2.2.19 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required630 Amp, 50 KA, FPMCCB

2

-

-

... More
HVAC ITEMS

-

-

-

... More
od132247/2023_2024 : AIR HANDLING UNIT<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>GROUND FLOOR<br>9 TR 4000CFM, 6 row. AHU'S 25mm static - MODULE 7, <br>9 TR 4000CFM, 6 row. AHU'S 25mm static - ENTRANCE FOYER<br>

2

-

-

... More
od132248/2023_2024 : AIR HANDLING UNIT<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>FIRST FLOOR<br>9 TR 3300CFM, 6 row. AHU'S 25mm static - LAB2, <br>SECOND FLOOR<br>9 TR 3300CFM, 6 row. AHU'S 25mm static - LAB2, <br>THIRD FLOOR<br>9 TR 3300CFM, 6 row. AHU'S 25mm static - LAB2, <br>FOURTH FLOOR<br>9 TR 3300CFM, 6 row. AHU'S 25mm static - LAB2, <br><br>

4

-

-

... More
od132251/2023_2024 : AIR HANDLING UNIT<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>FIFTH FLOOR<br>8 TR 3500CFM, 6 row. AHU'S 25mm static - LAB11, <br>8 TR 3500CFM, 6 row. AHU'S 25mm static - LAB11, <br>

2

-

-

... More
od132257/2023_2024 : AIR HANDLING UNIT<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>8.5 TR 3750CFM, 6 row. AHU'S 25mm static - LAB12, <br>8.5 TR 3750CFM, 6 row. AHU'S 25mm static - LAB12, <br>

2

-

-

... More
od132258/2023_2024 : AIR HANDLING UNIT<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>12 TR 4250 CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>12 TR 4250 CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>

2

-

-

... More
od132260/2023_2024 : LAMINAR FLOW PANELS WITH HEPA FILTERS<br>Unidirectional Laminar flow plenum for the CLEAN ROOM with HEPA filters .plenum construction with 1 mm thick aluminium sheet,perforated diffuser:1 mm thick stainless stel(ss 304),19mm thick class"O" nitrile insulation with aluminium foil lamination on exterior side, SS 'L' angle brackets for ceiling suspension of the plenum. all in line with the CLEAN ROOM standards.<br>

2

-

-

... More
od133982/2023_2024 : Supply , testing & commissioning of AHU Kit for connecting the AHU/ TFA/ AHU WITH HRW to VRF System with communication adapter and with necessary supports and accessories.<br>

31

-

-

... More
od133990/2023_2024 : Supply, Installation, Testing & commissioning of inverter type DX Condensing out door unit with R-410A/R-407C. It should be include, temperature controlle, sensors along with the control box, transforme, relays,door neccessary, Air hndling unit expansion kit, Power and control wiring between the thermostat controller, gas charging, channel support as per the site condition and the communication cabling betweeen uotdoor to indoor unit,Electrical cabling up to isolator. The capacities for the same is listed under:<br>OUT DOOR FOR TFA'S<br>11 TR<br>

11

-

-

... More
od133992/2023_2024 : Supply, Installation, Testing & commissioning of inverter type DX Condensing out door unit with R-410A/R-407C. It should be include, temperature controlle, sensors along with the control box, transforme, relays,door neccessary, Air hndling unit expansion kit, Power and control wiring between the thermostat controller, gas charging, channel support as per the site condition and the communication cabling betweeen uotdoor to indoor unit,Electrical cabling up to isolator. The capacities for the same is listed under:<br>OUT DOOR FOR TFA'S<br>5.5 TR<br>

2

-

-

... More
od140207/2023_2024 : REFRIGERANT COPPER PIPES FOR TFA <br>Supply,Installation and commissioning of copper refrigerant piping, complete with 13mm thick closed cell Class O Nitrile Rubber Insulation, fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Refrigerant piping to be measured based on the distance between the indoor and outdoor units irrespective of number of circuits. The piping will be measured as one length for suction and liquid line. Insulation will be measured along with the piping and not be claimed as extra. Copper tubes, shall be with thickness conforming to L type to ATM standards.The tubes shall be bright annealed copper upto and including 15 mm size.<br>

300

-

-

... More
od140284/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS MODULE 1<br>HIGH STATIC DCT IDU , 8TR X 1NOS MODULE 2<br>HIGH STATIC DCT IDU , 8TR X 1NOS DISCUSION AREA<br>HIGH STATIC DCT IDU , 8TR X 1NOS MAN. FACILITY/HEAVY MACHINE<br>HIGH STATIC DCT IDU , 8TR X 1NOS MAN. FACILITY/HEAVY MACHINE<br>HIGH STATIC DCT IDU , 8TR X 1NOS MAN. FACILITY/PASSAGE<br>HIGH STATIC DCT IDU , 8TR X 1NOS MAN. FACILITY/PASSAGE<br>

7

-

-

... More
od140286/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS MODULE 3<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS MODULE 4<br>

2

-

-

... More
od140290/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS MODULE 5<br>HIGH STATIC DCT IDU , 6.2TR X 1 NOS MODULE 6<br>HIGH STATIC DCT IDU , 6.2TR X 1 NOS MODULE 6<br>

3

-

-

... More
od141881/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>2 TR HI WALL SPLIT UNIT X 1NOS (UPS ROOM)<br>2 TR HI WALL SPLIT UNIT X 1NOS (UPS ROOM)<br>

2

-

-

... More
od141884/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 1<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 11<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 12<br><br>

3

-

-

... More
od141885/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 3<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 4<br>

2

-

-

... More
od141886/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LAB 5<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS WIDE LOBBY NEAR LAB15<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LOBBY NEAR LAB 16<br>

3

-

-

... More
od141887/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 6<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 7<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 8<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 9<br><br><br>

4

-

-

... More
od141888/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 10<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 13<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 14<br>

3

-

-

... More
od141891/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 1<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 11<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 12<br>HIGH STATIC DCT IDU , 8TR X 1NOS BOARD ROOM 4<br>

4

-

-

... More
od141892/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 3<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 4<br><br>

2

-

-

... More
od141894/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LAB 5<br>

1

-

-

... More
od141895/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 6<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 7<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 8<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 9<br><br>

4

-

-

... More
od141898/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 10<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 13<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 14<br>

3

-

-

... More
od141901/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>FOUR WAY CASSETTE IDU 1.2 TR X 1NOS LOBBY OF BOARD ROOM<br>

1

-

-

... More
od141903/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS WIDE LOBBY NEAR BOARD ROOM<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LOBBY NEAR NEAR BREAK AREA<br>

2

-

-

... More
od141915/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>FOUR WAY CASSETTE IDU 1.6 TR X 1NOS BOARD ROOM 1<br>

1

-

-

... More
od141916/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>FOUR WAY CASSETTE IDU 3.2 TR X 1NOS BOARD ROOM 2<br>

1

-

-

... More
od141919/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>FOUR WAY CASSETTE IDU 2 TR X 1NOS BOARD ROOM 3<br>

1

-

-

... More
od141920/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>THIRD FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 1<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 11<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 12<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 15<br>HIGH STATIC DCT IDU , 8TR X 1NOS , LAB 16<br>

6

-

-

... More
od141924/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>THIRD FLOOR<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 3<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 4<br>

2

-

-

... More
od141943/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>THIRD FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LAB 5<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS WIDE LOBBY NEAR LAB15<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LOBBY NEAR LAB 16<br>

3

-

-

... More
od141945/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of following. All Indoor Units shall be factory assembled, wired and tested. <br>THIRD FLOOR<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 6<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 7<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 8<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 9<br><br>

4

-

-

... More
od141947/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>THIRD FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 10<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 13<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 14<br>HIGH STATIC DCT IDU 6.2 TR X 1 NOS LAB 15<br>

4

-

-

... More
od141951/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of following. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 1<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 11<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 12<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 15<br>HIGH STATIC DCT IDU 8TR X 1 NOS LAB 16<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 16<br>

6

-

-

... More
od141952/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 3<br>HIGH STATIC DCT IDU , 4TR X 1NOS LAB 4<br>

2

-

-

... More
od141953/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LAB 5<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS WIDE LOBBY NEAR LAB15<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LOBBY NEAR LAB 16<br>

3

-

-

... More
od141955/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 6<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 7<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 8<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 9<br>

4

-

-

... More
od141956/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 10<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 13<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 14<br>HIGH STATIC DCT IDU 6.2 TR X 1 NOS LAB 15<br>

4

-

-

... More
od141958/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIFTH FLOOR<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 2<br>HIGH STATIC DCT IDU , 8TR X 1NOS LAB 3<br>

2

-

-

... More
od141959/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIFTH FLOOR<br>HIGH STATIC DCT IDU , 4.5TR X 1NOS LAB 1<br>

1

-

-

... More
od141960/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIFTH FLOOR<br>HIGH STATIC DCT IDU , 3.2TR X 1NOS LAB 4<br>

1

-

-

... More
od141961/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIFTH FLOOR<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LAB 5<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS LOBBY NEAR LAB 12<br>HIGH STATIC DCT IDU , 6.2TR X 1NOS WIDE LOBBY NEAR LAB11<br>

3

-

-

... More
od142033/2023_2024 : Supply,Installation and commissioning of copper ref nut joint with insulation ,with all necessary support and accessories<br>

94

-

-

... More
od142271/2023_2024 : Supply, Installation and commissioning of Branch Kit for outdoor with insulation ,with all necessary support and accessories<br>

50

-

-

... More
od142272/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>32 MM Dia<br>

700

-

-

... More
od142273/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>25 MM Dia<br>

400

-

-

... More
od142297/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>40 MM Dia<br>

500

-

-

... More
od142298/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>TERRACE FLOOR<br> 9000 CFM, 50MM FOR TOILET EXHAUST <br>

1

-

-

... More
od142299/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>TERRACE FLOOR<br> 10800 CFM, 50MM FOR TOILET EXHAUST <br>

1

-

-

... More
od142302/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>50 MM Dia<br>

270

-

-

... More
od142304/2023_2024 : Supply, installation, balancing and commissioning of fabricated at site Aluminium sheet rectangular ducting complete with rubber gaskets, elbows, splitter dampers, vanes, hangers, supports , sealent etc. as per approved drawings and specifications of following sheet thickness complete as required. FOR CLEAN ROOM<br>22 Gauge <br>

370

-

-

... More
od142305/2023_2024 : Supply, installation, balancing and commissioning of fabricated at site Aluminium sheet rectangular ducting complete with rubber gaskets, elbows, splitter dampers, vanes, hangers, supports , sealent etc. as per approved drawings and specifications of following sheet thickness complete as required. FOR CLEAN ROOM<br>24 Gauge <br>

75

-

-

... More
od142309/2023_2024 : Supply, Installation, testing, commissioning and commissioning of GI Volume control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages flanges etc as per specifications<br>

5

-

-

... More
od142310/2023_2024 : Supply, installation, testing and commissioning of AL volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. FOR CLEAN ROOM<br>

4

-

-

... More
od142311/2023_2024 : Supply, Installation, testing, commissioning and balancing of GSS powder coated fresh air/exhaust air louver with 4 side flanges, Bird netscreen, damper arrangement and all neccessary supprt and accessories , color should be approved by architect as per drawing. <br>

5

-

-

... More
od142318/2023_2024 : Circular Diffusers For Toilet<br>Powder coated, extruded aluminium, removable centre core type, supply / return air diffusers without volume control dampers of aluminium construction of the following neck sizes. The diffuser shall be mounted in the GI box (not in scope), with inlet connector suitable for flexible duct. Collar damper, GI Box & Flexible duct quantified separately. Measurement shall be based on outer to outer size of the air terminal device ( colour for the diffuser to be confirmed by Arch/ PMC team before placing the order) <br>150mm dia<br>

200

-

-

... More
od142320/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>"The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>"<br>150 mm dia<br>

500

-

-

... More
od142321/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>"The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>"<br>300 mm dia<br>

800

-

-

... More
od142322/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>"The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>"<br>250 mm dia<br>

800

-

-

... More
od142323/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>300 mm dia<br>

400

-

-

... More
od142324/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>250 mm dia<br>

400

-

-

... More
od142325/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>150 mm dia<br>

200

-

-

... More
od142326/2023_2024 : FACTORY FABRICATED SPILL AIR BOXES<br>Supply,installation,testing & commissioning of 525 x 525 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling <br>

800

-

-

... More
od142327/2023_2024 : FACTORY FABRICATED SPILL AIR BOXES<br>Supply,installation,testing & commissioning of 600 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling <br>

10

-

-

... More
od142328/2023_2024 : FACTORY FABRICATED SPILL AIR BOXES<br>Supply,installation,testing & commissioning of 750 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling <br>

10

-

-

... More
od142329/2023_2024 : FACTORY FABRICATED SPILL AIR BOXES<br>Supply,installation,testing & commissioning of 1000 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling <br>

10

-

-

... More
od142330/2023_2024 : supply & fixing of 9 mm thick Class O nitrile rubber HT insulation / EPDM Insulation of duct using with antimicrobial property with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.R-value for the insulating material shall be minimum 0.6( m2. K/W)<br>

5000

-

-

... More
od142331/2023_2024 : supply & fixing of 10 mm thick acoustic insulation of duct using with adhesive as per the recommendation of the manufacture with density 140-180kg/m3<br>

1800

-

-

... More
od142332/2023_2024 : Supply and fixing of underdeck insulation with 13mm thick fire retaradent class nitril rubber stuck with synthetic adhesive and held in position with GI screw at 600mm centres and cross braced with GI 20SWG wire netting <br>

10

-

-

... More
od142333/2023_2024 : "Non ac area duct insulation:<br>Supply & fixing of minimum 19 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Thermal conductivity to be minimum 0.033 @ 0 deg C mean temperature and water vapour diffussion resistance should be 10000 without any external vapour barrier."<br>

10

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

2500

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

500

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

2

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

270

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

270

-

-

... More
od142360/2023_2024 : Supply, installation, testing and commissioning of aluminum powder coated grille with out colar damper complete with all necessary support and acessories as per specifications and drawing.Defflection of the grille as per the site condition and color to be finalised with architect<br>

2

-

-

... More
od198668/2023_2024 : Supply & installation,testing and commisioning of Central Monitoring Unit suitable for monitoring and controlling of all outdoor and indoor units. Total number of Central Monitoring units shall be capable of connecting to all the above indoor units and outdoor units of each floor. Item shall be with display unit,controller, software and all other accessories required.<br>

7

-

-

... More
od198684/2023_2024 : "Supply, installation, testing, balancing and commissioning of 18G Motorized Volume control dampers with actuators, control panel, and Control Module. Volume control Damper shall be electronically controlled networkable controller type complete with low leakage damper actuator, microprocessor based programmable control unit, power supply unit and control transformer etc. The Damper shall be capable of accepting CO2 sensor signal. In the event of communication/network failure the Damper shall function on standalone/ manual override mode.<br>A suitable device shall be provided for the field adjustment of minimum/maximum air flow. All dampers shall be initially factory set at minimum air quantity of 50% to 110% of the design requirements"<br>

12

-

-

... More
od198688/2023_2024 : Supply, installation, testing,balancing and commissioning of CO2 Sensors with Control Panel and cabling in each AHU Room for modulating Fresh Air Supply to AHU Room with necessary supports and accessories<br>

111

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

500

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

100

-

-

... More
od198693/2023_2024 : Supply, installation, testing,balancing and commissioning of Motorised Fire dampers with actuators, control panel, and Control Module . Necessary control panels shall be included to take fire signal and close the FD and switch of the AHU. The fire rating of the damper shall be of 90min. Fire damper shall be with 450 / 600 mm sleeves suitable for the wall mounting. Fire damper shall open automatically when fault singnal is removed. Fire damper actuator shall have 10Nm torque upto 1Sqm size & 20 Nm from 1.1sqm to 2.4 Sqm. of damper face area necessary supports and accessories<br>

3

-

-

... More
od198773/2023_2024 : "Supplying, installing, testing and commissioning of factory built Floor Mounted double skin DX type Air Handler units for Treated Fresh Air made of 25 mm thick panels consisting of pre plasticized GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward curved centrifugal fan, 8 row deep cooling coil section with DX Coil copper tubes; Filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron. Blower shall be driven by Plug fan controlled by VFD with IE-3 TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply; the VFD shall be fedback by duct mounted air pressure sensor. <br>Complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per specifications of following capacities:<br>38.0 TR TFA 11400 CFM , 120 MM ESP, 8 ROW Coil double skin AHU with Plug fan complete with VFD drive with Duct static pressure sensor <br>"<br>

1

-

-

... More
od198775/2023_2024 : "Supplying, installing, testing and commissioning of factory built Floor Mounted double skin DX type Air Handler units for Treated Fresh Air made of 25 mm thick panels consisting of pre plasticized GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward curved centrifugal fan, 8 row deep cooling coil section with DX Coil copper tubes; Filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron. Blower shall be driven by Plug fan controlled by VFD with IE-3 TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply; the VFD shall be fedback by duct mounted air pressure sensor. <br>Complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per specifications of following capacities:<br>35.0 TR TFA 10500 CFM , 120 MM ESP, 8 ROW Coil double skin AHU with Plug fan complete with VFD drive with Duct static pressure sensor <br>"<br>

1

-

-

... More
od198776/2023_2024 : "Supplying, installing, testing and commissioning of factory built Floor Mounted double skin DX type Air Handler units for Treated Fresh Air made of 25 mm thick panels consisting of pre plasticized GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward curved centrifugal fan, 8 row deep cooling coil section with DX Coil copper tubes; Filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron. Blower shall be driven by Plug fan controlled by VFD with IE-3 TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply; the VFD shall be fedback by duct mounted air pressure sensor. <br>Complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per specifications of following capacities:<br>34.0 TR TFA 9800 CFM , 120 MM ESP, 8 ROW Coil double skin AHU with Plug fan complete with VFD drive with Duct static pressure sensor <br>"<br>

1

-

-

... More
od198852/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>TERRACE FLOOR<br> 3800 CFM, 80MM FOR ELECTRICAL ROOM EXHAUST <br>

1

-

-

... More
od222053/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>FIRST FLOOR<br>10 TR 4000CFM, 6 row. AHU'S 25mm static - LAB15, <br>10 TR 4000CFM, 6 row. AHU'S 25mm static - LAB16, <br>10 TR 4000CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>10 TR 4000CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br><br>

4

-

-

... More
od222055/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>SECOND FLOOR<br>10 TR 4500CFM, 6 row. AHU'S 25mm static - BREAK OUT AREA <br>

1

-

-

... More
od222322/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>SECOND FLOOR<br>10 TR 4100CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>10 TR 4100CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>

2

-

-

... More
od222357/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>THIRD FLOOR<br>10 TR 3300CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>10 TR 3300CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>FOURTH FLOOR<br>10 TR 3300CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>10 TR 3300CFM, 6 row. AHU'S 80mm static - FOYER AND PASSAGE <br>

4

-

-

... More
od227636/2023_2024 : CONTROL & WIRING FOR CLEAN ROOM<br>Supply, installation and commissioning of humidistats and control wiring between the strip heaters and humidistats with necessory accessories like relays, transformers, sensors etc. with Strip Heater 3KW <br><br>

7

-

-

... More
od229754/2023_2024 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel and cabling between atarter panel and fan. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. <br> 1000 CFM FRESH AIR BLOWER FOR STP (30MM)<br>

1

-

-

... More
od229755/2023_2024 : Supply installation testing and commissioning of AMCA Certified Inline Centrifugal fresh air Fans shall be with direct driven centrifugal fan, circular section, suitable for ceiling suspension/mounting,dol Starter panel and cabling between atarter panel and fan. The units shall be complete with flexible duct connections at inlet and outlet. The motor shall be protected by thermal contact relay as protection against burn-out. <br>1750 CFM FRESH AIR FAN FOR FIRE PUMP ROOM (20MM)<br>

1

-

-

... More
od229756/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>1200 CFM,30.mm for STP <br>

1

-

-

... More
od229757/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>2200 CFM, 20mm for fire pump room<br>

1

-

-

... More
od229760/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>26000 CFM, 80MM FOR GROUND FLOOR MACHINE ROOM

1

-

-

... More
od231988/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>22 HP FOR FIRST FLOOR<br>

1

-

-

... More
od231989/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>28 HP FOR SECOND FLOOR<br>

1

-

-

... More
od231990/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>34 HP FOR THIRD FLOOR AND FOURTH FLOOR<br>

2

-

-

... More
od231991/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>48 HP FOR MEZANANE FLOOR<br>

1

-

-

... More
od231992/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>52 HP FOR FIFTH FLOOR<br>

1

-

-

... More
od231993/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>60 HP FOR GROUND FLOOR, FIRST FLOOR, SECOND FLOOR, THIRD FLOOR, FOURTH FLOOR, FIFTH FLOOR, MEZANANE FLOOR<br>

11

-

-

... More
od231994/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>54 HP FOR GROUND FLOOR<br>

1

-

-

... More
od232915/2023_2024 : FRESH AIR FANS -AXIAL FLOW TYPE<br>Supply, installation, testing and commissioning of tube/vane<br>axial flow type supply air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy<br>impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction<br>motor (EFF-1/IE-2) and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply,<br>Suitable capacity of TP isolator within M.S enclosure box as required and as per specifications. Fans<br>should be AMCA certified . The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan<br>should be complete with all accessories including fire rated canvas connection with metallic flange,<br>vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should<br>not be less than 65%, PRESSURIZATION FAN7000 CFM, SP=30mm wg<br>with damper motor 24v 3-p 8NM,<br>Airflow switch range 20-200 pa, switching diffrential 10pa.<br>fire alarm inlet,<br>duct pressure pick up,<br>relay 24vac, with base,<br>BAC net DDC Controller <br>

4

-

-

... More
od232916/2023_2024 : FRESH AIR FANS -AXIAL FLOW TYPE<br>Supply, installation, testing and commissioning of tube/vane<br>axial flow type supply air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy<br>impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction<br>motor (EFF-1/IE-2) and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply,<br>Suitable capacity of TP isolator within M.S enclosure box as required and as per specifications. Fans<br>should be AMCA certified . The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan<br>should be complete with all accessories including fire rated canvas connection with metallic flange,<br>vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should<br>not be less than 65%, PRESSURIZATION FAN16000 CFM, SP=30mm wg<br>with damper motor 24v 3-p 8NM,<br>Airflow switch range 20-200 pa, switching diffrential 10pa.<br>fire alarm inlet,<br>duct pressure pick up,<br>relay 24vac, with base,<br>BAC net DDC Controller

3

-

-

... More
od232917/2023_2024 : SUPPLY, FABRICATION, INSTALLATION AND TESTING OF THE FLEXIBLE CANVAS CONNECTIONS CONSTRUCTED OUT OF FIRE RESISTANT DOUBLE CANVAS SLEEV AS PER THE SHOP DRAWING

15

-

-

... More
od233954/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>54 MM <br>

170

-

-

... More
od233955/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>41.3 MM <br>

292

-

-

... More
od233956/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>34.9 MM <br>

205

-

-

... More
od233957/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>28.6 MM<br>

570

-

-

... More
od233958/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>22.2 MM <br>

233

-

-

... More
od233959/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>19.1 MM <br>

301

-

-

... More
od233960/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>15.9 MM <br>

250

-

-

... More
od233961/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>12.7 MM <br>

225

-

-

... More
od233962/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>9.5 MM <br>

170

-

-

... More
od233963/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>6.4 MM <br>

80

-

-

... More
od234796/2023_2024 : TENANT BILLING SYSTEM<br>Supply, installation, testing, balancing and commissioning of Tenant Billing Software which can capture the exact power consumption by each user, generate various reports, usage patterns and user-wise monthly bills.

1

-

-

... More
od235173/2023_2024 : Supply, Installation, Testing and Commissioning of floor mounted AHU TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEEL & VFD DUAL MOTOR FRO SUPPLY RETURNS FAN . Summer ambient conditions : 95deg F, WBT - 82 Deg F, Return air condition : DBT-75 Deg F, RH - 55% . SUPPLY FAN Static - 60to 70 mm WG . Return fan - 40 mm to 60 mm WG. Efficiency - 80-85 %<br>48 TR 9000 CFM <br>

2

-

-

... More
MACHINE SIDE

-

-

-

... More
od87859/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>GROUND FLOOR<br>8 TR 3800CFM, 6 row. AHU'S 50mm static - CO- WORKING SPACE<br>

1

-

-

... More
od87860/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>GROUND FLOOR<br>9 TR 4700CFM, 6 row. AHU'S 50mm static - ADMINISTRATION WITH PASSAGE<br>

1

-

-

... More
od87861/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>GROUND FLOOR<br>15 TR 5800CFM, 6 row. AHU'S 50mm static - ENTRANCE LOBBY&DOUBLE HEIGHT AREA<br>

1

-

-

... More
od87862/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>FIRST FLOOR<br>9TR 4700CFM, 6 row. AHU'S 50mm static - ADMINISTRATION WITH PASSAGE<br>

1

-

-

... More
od87863/2023_2024 : FIRST FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br><br>8 TR 3900CFM, 6 row. AHU'S 50mm static - CO- WORKING SPACE<br>

2

-

-

... More
od87864/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>SECOND FLOOR<br>11TR 4600CFM, 6 row. AHU'S 50mm static - DINING <br>

2

-

-

... More
od87865/2023_2024 : SECOND FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>14TR 6400CFM, 6 row. AHU'S 50mm static - R&D WING SPACE<br>

2

-

-

... More
od87866/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>THIRD FLOOR<br>13TR 5500CFM, 6 row. AHU'S 50mm static - SOFTWARE WING<br>

1

-

-

... More
od87867/2023_2024 : THIRD FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>14TR 6400CFM, 6 row. AHU'S 50mm static - R&D WING SPACE<br>

2

-

-

... More
od87868/2023_2024 : THIRD FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>9TR 3750CFM, 6 row. AHU'S 50mm static - SOFTWARE WING & PASSAGE<br>

2

-

-

... More
od87869/2023_2024 : THIRD FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br><br>12TR 5500CFM, 6 row. AHU'S 50mm static - SOFTWARE WING<br>

1

-

-

... More
od87870/2023_2024 : "<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>FOURTH FLOOR<br>15TR 5500CFM, 6 row. AHU'S 50mm static - SOFTWARE WING<br>

2

-

-

... More
od87874/2023_2024 : FOURTH FLOOR<br>""" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>16TR 7700CFM, 6 row. AHU'S 50mm static - R&D WING SPACE<br>

2

-

-

... More
od87875/2023_2024 : FOURTH FLOOR<br>"<br>"" Supply, Installation, Testing and Commissioning of Ceiling Suspended AHU mounted horizontal ,double skin with thermal break profile low noise type Air Handling Units , (complete with DX type cooling coil, condensate drain pan (extended), made of 40mm thick panels consisting of pre plasticized GI casing of thickness 0.8mm outside layer and inner layer shall be of 0.8mm plain GI sheet with polyurethane form(PUF) insulation factory injected between them by injection moulding machine with thermal break profile complete with fan section with backward curved plug fans suitable for static pressure as required with VFD drives , coil section with aluminium finned copper tubes (min. 10 fins per inch, tube thickness not less than 0.5mm),Cooling coil of 6 rows deep, filter section with 50mm thick metal viscous/washable synthetic type air prefilters (10 micron) &,drain connections, SS drain pan(18G) with PUF insulation, TEFC sq.cage induction motor of efficiency class IE3 suitable for 415+-10% volts, 50 Hz, 3 phase AC supply including mounting and fixing arrangements, anti vibration springs/ isolator bearings etc complete as per specification and of following capacities.The cost shall be inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFDs shall be used ."<br>9TR 3750CFM, 6 row. AHU'S 50mm static - SOFTWARE WING & PASSAGE<br>

2

-

-

... More
od87881/2023_2024 : Supply , testing & commissioning of AHU Kit for connecting the AHU to VRF System with communication adapter and with necessary supports and accessories.<br>

24

-

-

... More
od87883/2023_2024 : Supply, Installation, Testing & commissioning of inverter type DX Condensing out door unit with R-410A/R-407C. It should be include, temperature controlle, sensors along with the control box, transforme, relays,door neccessary, Air hndling unit expansion kit, Power and control wiring between the thermostat controller, gas charging, channel support as per the site condition and the communication cabling betweeen uotdoor to indoor unit,Electrical cabling up to isolator. The capacities for the same is listed under:<br>OUT DOOR FOR TFA'S<br>5.5 TR<br>

1

-

-

... More
od87884/2023_2024 : Supply, Installation, Testing & commissioning of inverter type DX Condensing out door unit with R-410A/R-407C. It should be include, temperature controlle, sensors along with the control box, transforme, relays,door neccessary, Air hndling unit expansion kit, Power and control wiring between the thermostat controller, gas charging, channel support as per the site condition and the communication cabling betweeen uotdoor to indoor unit,Electrical cabling up to isolator. The capacities for the same is listed under:<br>OUT DOOR FOR TFA'S<br>11 TR<br>

4

-

-

... More
od87885/2023_2024 : Supply,Installation and commissioning of copper refrigerant piping, complete with 13mm thick closed cell Class O Nitrile Rubber Insulation, fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Refrigerant piping to be measured based on the distance between the indoor and outdoor units irrespective of number of circuits. The piping will be measured as one length for suction and liquid line. Insulation will be measured along with the piping and not be claimed as extra. Copper tubes, shall be with thickness conforming to L type to ATM standards.The tubes shall be bright annealed copper upto and including 15 mm size.<br>

80

-

-

... More
od87906/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>2 TR HI WALL SPLIT UNIT 1D+1S (UPS ROOM)<br>

2

-

-

... More
od87907/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>1.3 TR FOURWAY CASSETTE (MEETING ROOM 1)<br>

1

-

-

... More
od87908/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>1.5 TR FOURWAY CASSETTE (MEETING ROOM 2)<br>

1

-

-

... More
od87909/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>GROUND FLOOR<br>8 TR HIGH STATIC DUCT IDU (R&D WING SPACE, ADMIN, CO- WORK SPACE<br>

4

-

-

... More
od87912/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>1.5 TR FOURWAY CASSETTE (PA TO CEO)<br>

1

-

-

... More
od87913/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR<br>8 TR HIGH STATIC DUCT IDU (R&D WING SPACE, ADMIN, LOBY<br>

4

-

-

... More
od87914/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FIRST FLOOR, second floor, third floor, and fourth floor<br>2.5 TR FOURWAY CASSETTE (CEO CABIN)<br>

5

-

-

... More
od87915/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR and THIRD FLOOR <br>4.5 TR HIGH STATIC DUCT IDU (BOARD ROOM 1<br>

2

-

-

... More
od87916/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>2 TR FOURWAY CASSETTE (MEETING 1<br>

1

-

-

... More
od87918/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR<br>4 TR MID STATIC DUCT IDU (BOARD ROOM 1<br>

1

-

-

... More
od87919/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>SECOND FLOOR AND FOURTH FLOOR <br>6.2 TR HIGH STATIC DUCT IDU

3

-

-

... More
od87925/2023_2024 : Supply at site with full cover insurance from factory to site along with Installation, Testing & commissioning of the indoor units with Cordless remotes,control cabling between indoor & out door units in pvc conduit, , conduit accessories and necessary fixing arrangement Interlocking of Indoor & Out door Units and Required sensors .Capacity minimum of Ffollowing. All Indoor Units shall be factory assembled, wired and tested. <br>FOURTH FLOOR<br>2.5 TR FOURWAY CASSETTE IDU (MEETING ROOM<br>

1

-

-

... More
od87937/2023_2024 : Supply,Installation and commissioning of Branch Kit for outdoor with insulation ,with all necessary support and accessories<br>

18

-

-

... More
od87938/2023_2024 : Supply,Installation and commissioning of copper ref nut joint with insulation ,with all necessary support and accessories<br>

55

-

-

... More
od87939/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>40 MM Dia<br>

200

-

-

... More
od87940/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>32 MM Dia<br>

250

-

-

... More
od87941/2023_2024 : Supply, installation, testing & commissioning of following sizes insulated PVC drain pipe' from terminal units (AHUs, split units etc.) drain pans to nearest floor drain complete with interconnection, flanges, elbows, tees, nuts, U-trap etc. The insulation shall be 9 mm thick closed cell Class O Nitrile Rubber foam insulation.<br>25 MM Dia<br>

150

-

-

... More
od87943/2023_2024 : TERRACE FLOOR<br>Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>TERRACE FLOOR<br> 5000 CFM, 30MM FOR TOILET EXHAUST

1

-

-

... More
od87948/2023_2024 : Supply, Installation, testing, commissioning and commissioning of GI Volume control damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages flanges etc as per specifications

3

-

-

... More
od87949/2023_2024 : Supply, Installation, testing, commissioning and balancing of GSS powder coated fresh air/exhaust air louver with 4 side flanges, Bird netscreen, damper arrangement and all neccessary supprt and accessories , color should be approved by architect as per drawing.

1

-

-

... More
od87950/2023_2024 : Circular Diffusers For Toilet<br>Powder coated, extruded aluminium, removable centre core type, supply / return air diffusers without volume control dampers of aluminium construction of the following neck sizes. The diffuser shall be mounted in the GI box (not in scope), with inlet connector suitable for flexible duct. Collar damper, GI Box & Flexible duct quantified separately. Measurement shall be based on outer to outer size of the air terminal device ( colour for the diffuser to be confirmed by Arch/ PMC team before placing the order) <br>150mm dia<br>

70

-

-

... More
od87951/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>150 mm dia

101

-

-

... More
od87953/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>"The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>"<br>300 mm dia<br>

400

-

-

... More
od87954/2023_2024 : Insulated Flexible Ducting<br>Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 2 mtr <br>"The flexible duct shall me made of double lamination of aluminium foil, polyester and metalized polyester film permanently bonded to a coated spring steel wire helix. The exterior shall be wrapped with 25mm thick 24 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalized polyester film laminate. Clamps should be consider for fixing to spigot/butter fly damper with necessary fittings. Should include Also chain supports with clamps should be consider for flexible ducts where length is exceeding more than 1m & it should not rest on false ceiling.<br>"<br>250 mm dia<br>

200

-

-

... More
od87957/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>300 mm dia

200

-

-

... More
od87958/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>250 mm dia

100

-

-

... More
od87959/2023_2024 : Butterfly Dampers-22 Gauge with lockable option after air balancing with Visible indicators shall be considered<br>150 mm dia

50

-

-

... More
od87961/2023_2024 : Supply,installation,testing & commissioning of 600 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling

50

-

-

... More
od87962/2023_2024 : Supply,installation,testing & commissioning of 750 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling

10

-

-

... More
od87963/2023_2024 : Supply,installation,testing & commissioning of 1000 x 150 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling

65

-

-

... More
od87964/2023_2024 : FACTORY FABRICATED SPILL AIR BOXES<br>Supply,installation,testing & commissioning of 525 x 525 x 400 mm High Sheet Metal Spill air boxes made out of 24 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Chain /link supports should be consider for all four corners of the diffuser & hook support to be provide at centre of the mixing box to avoid resting on false ceiling

140

-

-

... More
od87967/2023_2024 : supply & fixing of 9 mm thick Class O nitrile rubber HT insulation / EPDM Insulation of duct using with antimicrobial property with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.R-value for the insulating material shall be minimum 0.6( m2. K/W)

1500

-

-

... More
od87968/2023_2024 : supply & fixing of 10 mm thick acoustic insulation of duct using with adhesive as per the recommendation of the manufacture with density 140-180kg/m3

280

-

-

... More
od146771/2023_2024 : "Non ac area duct insulation:<br>Supply & fixing of minimum 19 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Thermal conductivity to be minimum 0.033 @ 0 deg C mean temperature and water vapour diffussion resistance should be 10000 without any external vapour barrier."<br>

10

-

-

... More
od146801/2023_2024 : Supply and fixing of underdeck insulation with 13mm thick fire retaradent class nitril rubber stuck with synthetic adhesive and held in position with GI screw at 600mm centres and cross braced with GI 20SWG wire netting <br>

10

-

-

... More
16.12.2.1 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick

150

-

-

... More
16.12.2.2 : Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick

75

-

-

... More
od198804/2023_2024 : Supply, installation, testing,balancing and commissioning of Motorised Fire dampers with actuators, control panel, and Control Module . Necessary control panels shall be included to take fire signal and close the FD and switch of the AHU. The fire rating of the damper shall be of 90min. Fire damper shall be with 450 / 600 mm sleeves suitable for the wall mounting. Fire damper shall open automatically when fault singnal is removed. Fire damper actuator shall have 10Nm torque upto 1Sqm size & 20 Nm from 1.1sqm to 2.4 Sqm. of damper face area necessary supports and accessories<br>

1.5

-

-

... More
od198805/2023_2024 : Supply, installation, testing,balancing and commissioning of CO2 Sensors with Control Panel and cabling in each AHU Room for modulating Fresh Air Supply to AHU Room with necessary supports and accessories<br>

35

-

-

... More
od198806/2023_2024 : "Supply, installation, testing, balancing and commissioning of 18G Motorized Volume control dampers with actuators, control panel, and Control Module. Volume control Damper shall be electronically controlled networkable controller type complete with low leakage damper actuator, microprocessor based programmable control unit, power supply unit and control transformer etc. The Damper shall be capable of accepting CO2 sensor signal. In the event of communication/network failure the Damper shall function on standalone/ manual override mode.<br>A suitable device shall be provided for the field adjustment of minimum/maximum air flow. All dampers shall be initially factory set at minimum air quantity of 50% to 110% of the design requirements"<br>

6

-

-

... More
od198807/2023_2024 : Supply & installation,testing and commisioning of Central Monitoring Unit suitable for monitoring and controlling of all outdoor and indoor units. Total number of Central Monitoring units shall be capable of connecting to all the above indoor units and outdoor units of each floor. Item shall be with display unit,controller, software and all other accessories required.

5

-

-

... More
od198847/2023_2024 : "Supplying, installing, testing and commissioning of factory built Floor Mounted double skin DX type Air Handler units for Treated Fresh Air made of 25 mm thick panels consisting of pre plasticized GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward curved centrifugal fan, 8 row deep cooling coil section with DX Coil copper tubes; Filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron. Blower shall be driven by Plug fan controlled by VFD with IE-3 TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply; the VFD shall be fedback by duct mounted air pressure sensor. <br>Complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per specifications of following capacities:<br>24.0 TR TFA 7055 CFM , 120 MM ESP, 8 ROW Coil double skin AHU with Plug fan complete with VFD drive with Duct static pressure sensor <br>"<br>

1

-

-

... More
od198848/2023_2024 : "Supplying, installing, testing and commissioning of factory built Floor Mounted double skin DX type Air Handler units for Treated Fresh Air made of 25 mm thick panels consisting of pre plasticized GI casing of 0.6 mm thickness outside layer and plane GI of 0.6 mm thick inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW forward curved centrifugal fan, 8 row deep cooling coil section with DX Coil copper tubes; Filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron. Blower shall be driven by Plug fan controlled by VFD with IE-3 TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply; the VFD shall be fedback by duct mounted air pressure sensor. <br>Complete with drain connections with drain valve, stainless steel drain pan, necessary vibration isolation arrangement etc, complete as per specifications of following capacities:<br>18.0 TR TFA 5244 CFM , 120 MM ESP, 8 ROW Coil double skin AHU with Plug fan complete with VFD drive with Duct static pressure sensor <br>"<br>

1

-

-

... More
od198850/2023_2024 : Supply, installation, testing and commissioning Direct driven axial flow fans for exhaust suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , ≥ IE 3 : <br>TERRACE FLOOR<br> 1600 CFM, 80MM FOR ELECTRICAL ROOM EXHAUST <br>

1

-

-

... More
od232120/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>34 HP FOR FIRST FLOOR<br>

1

-

-

... More
od232121/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>36 HP FOR GROUND FLOOR<br>

1

-

-

... More
od232122/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>40 HP FOR GROUND, FIRST, SECOND AND THIRD FLOOR<br>

4

-

-

... More
od232123/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>48 HP FOR SECOND FLOOR AND THIRD FLOOR<br>

2

-

-

... More
od232124/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>50 HP FOR GROUND FLOOR<br>

1

-

-

... More
od232125/2023_2024 : VRF<br> Supply Installation Testing and commissioning of modular VRF Outdoor unit consisting of hermetically sealed inverter driven scroll compressor/Twin rottary compressor, motor and drive arrangement, air cooled condenser, initial charge of refrigerant (R-410A) and oil, integral refrigerant piping, expansion valve (if any), drier, sight glass, electrical panel with controls duly wired, starters, high-low pressure cutout, thermostatic control, supports for condenser unit etc. Outdoor units shall be designed for delivering 100% Capacity at 35 deg C ambient temperature.Equipment shall be capable of working at a voltage range of 320-460V without tripping. The aluminium fins of the condensor shall be hydrophillic & coated with anti corrosive fins for handling saline & extreme climatic conditions including pollution..Unit should include the necessary supporting arrangement of both the units with vibration isolators as per site condition & required length of electrical power cabling & control cabling between indoor & outdoor units etc. MS base frame for outdoor units complete with epoxy painting, vibration isolation pads, supports, hangers, railing, brackets etc including civil works<br>OUTDOOR UNIT<br>54 HP FOR GROUND FLOOR<br>

1

-

-

... More
od232894/2023_2024 : FRESH AIR FANS -AXIAL FLOW TYPE<br>Supply, installation, testing and commissioning of tube/vane<br>axial flow type supply air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy<br>impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction<br>motor (EFF-1/IE-2) and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply,<br>Suitable capacity of TP isolator within M.S enclosure box as required and as per specifications. Fans<br>should be AMCA certified . The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan<br>should be complete with all accessories including fire rated canvas connection with metallic flange,<br>vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should<br>not be less than 65%, PRESSURIZATION FAN6000 CFM, SP=30mm wg<br>with damper motor 24v 3-p 8NM,<br>Airflow switch range 20-200 pa, switching diffrential 10pa.<br>fire alarm inlet,<br>duct pressure pick up,<br>relay 24vac, with base,<br>BAC net DDC Controller <br>

3

-

-

... More
od232895/2023_2024 : FRESH AIR FANS -AXIAL FLOW TYPE<br>Supply, installation, testing and commissioning of tube/vane<br>axial flow type supply air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy<br>impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction<br>motor (EFF-1/IE-2) and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply,<br>Suitable capacity of TP isolator within M.S enclosure box as required and as per specifications. Fans<br>should be AMCA certified . The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan<br>should be complete with all accessories including fire rated canvas connection with metallic flange,<br>vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should<br>not be less than 65%, PRESSURIZATION FAN15500 CFM, SP=30mm wg<br>with damper motor 24v 3-p 8NM,<br>Airflow switch range 20-200 pa, switching diffrential 10pa.<br>fire alarm inlet,<br>duct pressure pick up,<br>relay 24vac, with base,<br>BAC net DDC Controller

2

-

-

... More
od232896/2023_2024 : SUPPLY, FABRICATION, INSTALLATION AND TESTING OF THE FLEXIBLE CANVAS CONNECTIONS CONSTRUCTED OUT OF FIRE RESISTANT DOUBLE CANVAS SLEEV AS PER THE SHOP DRAWING

8

-

-

... More
od234270/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>54 MM <br>

28

-

-

... More
od234271/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>41.3 MM <br>

73

-

-

... More
od234272/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>34.9 MM <br>

20

-

-

... More
od234273/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>28.6 MM<br>

305

-

-

... More
od234274/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>22.2 MM <br>

56

-

-

... More
od234275/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>19.1 MM <br>

66

-

-

... More
od234276/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>15.9 MM <br>

108

-

-

... More
od234277/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>12.7 MM <br>

50

-

-

... More
od234278/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>9.5 MM <br>

68

-

-

... More
od234279/2023_2024 : REFRIGERANT PIPING FOR VRF UNIT'S<br>Supply,Installation,Testing and commissioning of copper refrigerant piping,18 Gauge complete with 19 mm thick closed cell Class Nitrile Rubber Insulation and , fittings, elbows, bends, supporting and clambing arrangement on walls, cable trays/trenches including necessary civil works.Copper tubes, shall be with thickness conforming to VRF standards, with neccessary supports and accessories along with refrigerant charging .The copper pipe complete run over the riasers and terrace to be insulated with wheather proof protected five mill cloth with 2 layer vaopur barries forsters30-36 and the pipe run over the terrace to be supported with Ms angle support. (Insulation will be measured along with the piping and not be claimed as extra)<br>6.4 MM <br>

20

-

-

... More
od234710/2023_2024 : TENANT BILLING SYSTEM<br>Supply, installation, testing, balancing and commissioning of Tenant Billing Software which can capture the exact power consumption by each user, generate various reports, usage patterns and user-wise monthly bills.

1

-

-

... More
MACHINE SIDE PART 2

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

700

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

200

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

45

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

50

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

50

-

-

... More
od87982/2023_2024 : Supply, installation, testing and commissioning of aluminum powder coated grille with out colar damper complete with all necessary support and acessories as per specifications and drawing.Defflection of the grille as per the site condition and color to be finalised with architect<br>

65

-

-

... More
WET RISER SYSTEM-EQUIPMENT

-

-

-

... More
PIPING,VALVES AND ACCESSORIES

-

-

-

... More
od356293/2020_2021 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>150mm dia MS Pipe

1591

-

-

... More
od356353/2020_2021 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>100 mm dia

348

-

-

... More
od357383/2020_2021 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>80 mm dia

464

-

-

... More
od357424/2020_2021 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>65 mm dia

542.25

-

-

... More
od357473/2020_2021 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>50 mm dia

665

-

-

... More
od360453/2020_2021 : "Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>"<br>40 mm dia<br>

683

-

-

... More
od360455/2020_2021 : "Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>"<br>32 mm dia<br>

312

-

-

... More
od360456/2020_2021 : "Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>"<br>25 mm dia<br>

4130

-

-

... More
od360459/2020_2021 : "Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.<br>"<br>150 mm dia<br>

22

-

-

... More
od360461/2020_2021 : "Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required.<br>"<br>100 mm dia<br>

5

-

-

... More
od360477/2020_2021 : "Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.<br>"<br>150 mm dia<br>

4

-

-

... More
od360478/2020_2021 : "Providing, Installation, Testing and Commissioning of Gun Metal Ball Valves with brass body chrome plated of following sizes as required.<br>"<br>50 mm dia<br>

25

-

-

... More
od360480/2020_2021 : "Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.<br>"<br>

22

-

-

... More
od360482/2020_2021 : Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 .<br>

7

-

-

... More
od360483/2020_2021 : Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926.<br>

39

-

-

... More
od360489/2020_2021 : "Providing and fixing 25 mm dia inspecting & testing assembly with gunmetal isolation valve, gunmetal sight glass, bypass valve & connected to drain line complete (excluding the cost of drain pipe).<br>"<br>

22

-

-

... More
HYDRANTS SYSTEM

-

-

-

... More
od360495/2020_2021 : Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required.<br>Single headed Stainless steel<br>

39

-

-

... More
od360496/2020_2021 : Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.<br>Stainless Steel (Grade 304)<br>

78

-

-

... More
od360498/2020_2021 : "Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.<br>"<br>Stainless Steel (Grade 304)<br>

39

-

-

... More
od360500/2020_2021 : "Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.<br>"<br>"20 mm nominal internal dia water hose thermoplastic<br>(Textile reinforced) type -2 as per IS: 12585"<br>"20 mm nominal internal dia gun metal globe valve &<br>nozzle."<br>Drum and brackets for fixing the equipmets on wall.<br>"Connections from riser with 25 mm dia stop gun metal<br>valve & M.S. Pipe and socket."<br>"Connections from riser with 25 mm dia stop gun metal<br>valve & M.S. Pipe and socket."<br>30M<br>

39

-

-

... More
od360501/2020_2021 : SITC weather proof M.S Door and glass fire door size 2100 mm x 900 mm or as per arch.<br>Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following.<br>"a) Gunmetal single headed Hydrant valve - 1 No.<br>b) Fire Hoses 63mm, 15 M long with accessories - 2 Nos.<br>c) Short branch - 1 No.<br>d) First Aid hose Reel - 1 No.<br>e) Fire Extinguisher - 2 Nos.<br>f) Fireman's Axe - 1 No.<br>g) Pressure Gauge - 1 No.<br>The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.<br><br><br><br>"<br>

43

-

-

... More
od360506/2020_2021 : "Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.<br>"<br>Pendent Sprinkler<br>

2072

-

-

... More
od360527/2020_2021 : "Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.<br>"<br>Upright Sprinkler<br>

912

-

-

... More
od360535/2020_2021 : "Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.<br>"<br>150mm dia<br>

22

-

-

... More
od360542/2020_2021 : "Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.<br>1500 mm"<br>1500 mm<br>

912

-

-

... More
od86689/2023_2024 : Supply laying of 20mm dia Pvc conduit pipe with accesorries and ISI MARK.<br>

3000

-

-

... More
od86709/2023_2024 : Supply,Installation,Testing and Commissioning of 2C X 1.5 SQMM Multistranded flexible copper conductor cable with ISI MARK.<br>

6820

-

-

... More
od130519/2023_2024 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet withcommon keylock arrangements, suitable to accommodate two lengths of 15mtr hoses, and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside<br>

39

-

-

... More
od259893/2023_2024 : "Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.<br>1500 mm"<br>1000 mm<br

912

-

-

... More
FIRE EXTINGUISHERS

-

-

-

... More
od360551/2020_2021 : Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.<br>4.5kg capacity cylinder.<br>

39

-

-

... More
od86771/2023_2024 : ABC type Fire extinguishers:Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

92

-

-

... More
od255618/2023_2024 : ”Minimax” Modular Ceiling Mounted ABC Powder Type Fire Extinguisher, CE Certified,<br>Forged brass valve with Thermo bulb having release temperature of 68°C.<br>Product perfromance certification by National Test House (Govt of India)<br>MMX SP 5 Kg : Modular (MAP 90)

50

-

-

... More
FIRE ALARM PANEL

-

-

-

... More
od86779/2023_2024 : Supply,Installation, Testing and Commissioning of Fire alarm control panel capable of handling more then 99 devices / detectors per loop. The panel shall have Hazmat icons indicating the presence of explosive gas, liquids, poison,fumes etc and to meet the NFPA Standards and UL approvals. Panel should be expandable, networkable and having touch screen facility with a battery backup of 24 hrs in normal condition and 30 min in alarm condition.UL listed 32 bit Central processor with 6" touch screen LCD display supporting smart degrade mode operation and not limited with characters.UL listed Fire Fighter Touch Screen Graphical Display panel to inform & guide Fire Fighter for carring out Fire Fighter operation. The screen will display icons representing hazardous material stored on the floor, programmed building contact information, building occupancy and other general information .The panel should have minimum of 5 loop and should be expandable to 10 Loop.Else Vendor to consider the nos of loop with 85% Loading for Detectors in each loop. <br>

1

-

-

... More
od86780/2023_2024 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor,<br>single core cable in the existing surface/ recessed steel/ PVC conduit as required.<br>1C X 1.0 sq. mm

3020

-

-

... More
od86689/2023_2024 : Supply laying of 20mm dia Pvc conduit pipe with accesorries and ISI MARK.<br>

1850

-

-

... More
od86781/2023_2024 : Supply,Installation,Testing and Commissioning of heat detector with base unit,CE approved.

53

-

-

... More
od86782/2023_2024 : Supply,Installation,Testing and Commissioning of photo electric type smoke detectors with base unit,CE approved.

1148

-

-

... More
od86783/2023_2024 : Supply,Installation,Testing and Commissioning of sounder with strobe units,CE approved.

39

-

-

... More
od86784/2023_2024 : Supply,Installation,Testing and Commissioning of Manual pullstation break glass type,CE approved.

39

-

-

... More
od86786/2023_2024 : Supply insulation testing commisioning of response indicator,CE Approved

409

-

-

... More
od86787/2023_2024 : SIGNAGES:Fire Exit, Exit, Fire Lift & Fire Duct signage at each stair on every floor, indicating the direction of fire exit, lettering size shall be 7.5 cm with contrasting color from back ground as per standards. Size shall be 15cm x 60cm.

111

-

-

... More
od86788/2023_2024 : Supply , installation , testing and commisioning of Public Address speaker with talk back facility 6/12 Watts with LMT and call switch , made out of powder coated CRCA sheet , wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

39

-

-

... More
od86790/2023_2024 : Providing and installation in position Signage with printed SAFE ASSEMBLY AREA, of 1.25 cm height letters in red with white background.The size of the board shall be 40x30 cm and shall be fixed at the safe assembly areas demarked outside the building.

10

-

-

... More
od86801/2023_2024 : Supply installation testing & commissioning of 5 zone call station with Goose neck type microphone and with the following features : (i) Built in Powersupply. (ii) Zone Selector switching Circuit (iii) Terminal blocks to terminate zones wires.,(iv) Zone Call processing Circuit etc and made functional. Panel to be installed in the Fire Control Room.

2

-

-

... More
od259878/2023_2024 : Supply of Addressable Active Repeater Panel which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have CORTEX 64 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, and One Fire Relays, power Supply Board which will have SMPS fully protected board, which operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. the panel have IP-50 rating .<br>

3

-

-

... More
WET RISER SYSTEM - EQUIPMENTS

-

-

-

... More
od360825/2020_2021 : Supplying Installation, testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following Complete in all respect as required.(1 Hydrant + 1 Sprinkler )<br>Horizontal/Vertical type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow 2850 lpm @85m head conforming to IS 1520. (The pump should be capable of delivering 150 % rated discharge at a head not less than 65% of the rated head).<br>Suitable HP SQ cage induction motor, TEFC, synchronous speed 1470 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>Suitable CC foundation of 1:2:4 ratio (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) duly plastered and with anti-vibration pads.<br>

2

-

-

... More
od360827/2020_2021 : Supplying, Installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic as well as manual operation and consisting of following : complete in all respect as required.<br>Horizontal/Vertical type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow 2850 lpm@85 m head conforming to IS 1520. (The pump should be capable of delivering 150 % rated discharge at a head not less than 65% of the rated head) b) Suitable HP 1500 RPM diesel engine conforming to BS :649/IS:1601/IS:10002 all amended upto date, continuous duty, multi cylinders vertical 4 stroke cycle water cooled, developing suitable BHP at operating speed specified to drive the fire pump capable of driving continuous non-stop operation for 8 hours having 10% overload capacity for one hour in a period of 12 hours continuous run, capacity to accept full load within 15 seconds from the receipt of signal to start and complete with following accessories:<br>"a) Dynamically balanced fly-wheel.<br>b) Direct coupling for pump and coupling guards.<br>c) Radiator with hoses, fan water pump, drive arrangement and guard.<br>d) Air-cleaner dry type.<br>e) Fuel tank with necessary pipe.<br>f) Pump for lubricating oil and lubricating oil filter.<br>g) Electric starting system along with battery 12 V / 24 V .<br>h) Exhaust silencer (residential type) with necessary pipe work.<br>i) Governor.<br>j) Instrument panel housing all the gauges including tachometer, hour meter and starting switch with key (for manual starting.<br>k) Necessary safety controls. and stop solenoid in the event of fault.<br>l) Winterisation arrangement.<br>m) Hand operated semi-rotary hand pump for filling the service tank.<br>n) Required length of exhaust piping as per the norms duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding.<br>o) Painted in post office red colour.<br><br>"<br>Common bed plate fabricated out of MS channel of suitable size for assembling the Pump and the Engine, flexible coupling and with coupling guard for protection/safety.<br>Making cement concrete foundation of 1:2:4 ratio (1 Cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) duly plastered suitable for Diesel engine pump set including vibration isolation by providing cushy foot mount pads as necessary, foundation bolts, brackets, clamps, fixtures, grouting etc., in accordance with manufacturer's design etc.as per specification complete as required.<br>

1

-

-

... More
od360854/2020_2021 : SPRINKLER JOCKEY/HYDRANT FIRE PUMP<br>Supplying Installation, testing and Commissioning of electric driven main fire pump suitable for automatic operation and consisting of following Complete in all respect as required.<br>Horizontal/Vertical type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow 180 lpm @ 85 m head conforming to IS 1520. (The pump should be capable of delivering 150 % rated discharge at a head not less than 65% of the rated head).<br>Suitable HP SQ cage induction motor, TEFC, synchronous speed 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.<br>Suitable CC foundation of 1:2:4 ratio (1 Cement: 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) duly plastered and with anti-vibration pads.<br>

2

-

-

... More
od360857/2020_2021 : Fabricating, Supplying, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header in pump house fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve, complete with drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizes:<br>2 Meter high and 450 mm dia suitable to operate Jockey Pump, Main Fire Pump & Diesel Engine Driven Fire Pump.<br>

1

-

-

... More
od360858/2020_2021 : Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 - 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.<br>

7

-

-

... More
od83627/2023_2024 : "DIESEL ENGINE STARTER PANEL<br>Supply,storing,erection,testing and commissioning of wall mounted 24 volts control panel to start the fire pump engine automatically as per the following sequence of operation and the auxiliary arrangements.<br>a) Engine to start automatically incase of low water pressure secured by the pressure switch with necessary timers,relays etc.<br>b) Manual stopping<br>c) Audio visual alarm for :<br>i) Low fuel oil level<br>ii) Engine over speed<br>iii) High water temperature<br>iv) Low type oil pressure<br>v) Engine fails to start<br>d)A battery charger with trickle/Boost arrangements with secondary side tapping at 28,30,32 and 34volts equipped with silicon diodes to charge the starting battery of the diesel engine."<br>

1

-

-

... More
od86732/2023_2024 : Fabrication, supply, erection, testing and commissioning of Automatic motor control panel of cubicle type, dust and vermin proof, floor/wall mounted, front operated power control make MV panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel and including inbuilt fire spot panel protection unit of 4kg capacity, with heat detection tube of sufficient length which runs across the panel covering all devices etc including all components as required. All opening parts of the panel shall be sealable. Panel shall be fabricated with necessary provision for Class B + Class C/ Class 1 + Class 2 Surge arrestor device.Including providing surge arrestor and necessary MCCB switch for its protection and Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant. <br>This panel should include Pluggable type surge arrester Class B & Class C/ Class 1 & Class 2 as per IEC 61643 (IP 20) with potential free contact, with IP 66 completely assembled enclosure & provision for inbuilt common remote indication for defective arresters 3 nos of encapsulated spark gap & 3 nos of single large block of MOV with series thermal fuse and cooling gel to connect between Line and Neutral and one number arrester encapsulated spark gap type to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage -230V 50Hz, Impulse current-150 KA (10/350µ sec) & 60KA (8/20µ sec) for Line to Neutral & 125 KA(10/350µ sec) for Neutral to Protective Earth, voltage protection level <1.3 KV ( L to N) & <1.3 KV ( N to E). Operating temp -40º to +85ºC. Response time <100 nano sec<br>Incomer:500A TPN Isolator .<br>500A 415V, 16kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, kWh, KW, frequency, KVA, kVAr, PF, kVArh, Runhours, On hours, Interupts, RPM, % Unbalance (V,A), Phase angle, THD etc. - 1 No (for incomer).<br>RYB phase indicating LED lamps with control fuses and switches - 1 set.<br>CTs- ratio 500/5A 15VA CL-1 - 1 no. <br>Outgoing<br>250A, TP Isolator -2 NOS<br>63A, TP Isolator -2 NOS<br>250A Star delta starter.-2 NOS<br>63A Star delta starter.-2 NOS<br>Supply and installation<br>

1

-

-

... More
PIPING, VALVES AND ACCESSORIES

-

-

-

... More
od361045/2020_2021 : SLTC of M.S. pipe on surface<br>"Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.<br>"<br>200 mm dia (wall thickness 6.3 mm)<br>

20

-

-

... More
od361050/2020_2021 : "Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.<br>"<br>150 mm dia<br>

955

-

-

... More
od361147/2020_2021 : "Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.<br>"<br>200 mm dia<br>

2

-

-

... More
od361149/2020_2021 : "Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.<br>"<br>150 mm dia<br>

3

-

-

... More
od361151/2020_2021 : Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2 .<br>

2

-

-

... More
od361152/2020_2021 : Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.<br>150 mm dia<br>

2

-

-

... More
od361156/2020_2021 : "Providing & fixing double flanged Metallic expansion with M.S. fixed flanges (PN-1.6) joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required as per specifications.<br>"<br>150 mm dia<br>

3

-

-

... More
od86199/2023_2024 : """Providing & fixing controlled percolation fire hose pipe (as per IS:8423) of 63 mm dia and 15 meter<br>length rated for brust pressure of 3.5 Kg/sqcm. The hose shall be tested for flame resistance test in<br>accordance to IS:8423. Hose shall be complete with ISI marked SS male & female coupling (IS:903)<br>bound & riveted to hose pipe with copper rivets & 1.5 mm copper wire as required as per specifications.<br>(Location External Fire Hydrant).<br>""<br>"<br>

20

-

-

... More
od86200/2023_2024 : """Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal<br>seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following<br>sizes as required.<br>""<br>150 mm dia<br>"<br>

9

-

-

... More
od86217/2023_2024 : """Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal<br>seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following<br>sizes as required.<br>""<br>200 mm dia <br>"<br>

2

-

-

... More
od130735/2023_2024 : """Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size<br>nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as<br>required.<br>""<br>Stainless Steel (Grade 304)<br>"<br>

20

-

-

... More
HYDRANTS SYSTEM

-

-

-

... More
od361213/2020_2021 : "Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required.<br>"<br>4 way - 150 mm dia.<br>

2

-

-

... More
od361214/2020_2021 : SITC of sprinkler installation valve <br>"Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required.<br>150 mm dia"<br>

2

-

-

... More
od361215/2020_2021 : Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required.<br>Single headed Stainless steel<br>

10

-

-

... More
od130700/2023_2024 : Supply and Fixing of weather proof Hose cabinet suitable size "having made of 16 gauge MS Sheet withcommon keylock arrangements, suitable to accommodate two lengths of 15mtr hoses, and one no branch pipe with nozzle. The cabinet shall be painted to scarlet red colour out side and off-white inside<br>

10

-

-

... More
POWER CABLING

-

-

-

... More
od83742/2023_2024 : Supply and Laying of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc<br>3Cx 240 sq mm on wall, floor<br>

15

-

-

... More
od83943/2023_2024 : 3Cx 10 sq mm on wall, floor<br>

15

-

-

... More
MV CABLE JOINING AND END TERMINATION

-

-

-

... More
od84075/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Earthing shall be availed from the electrical system)<br>3C x 240 sq mm on wall, floor<br>

2

-

-

... More
od84102/2023_2024 : 3C x 10 sq mm on wall, floor<br>

2

-

-

... More
od84912/2023_2024 : Supply, erection, commissioning of additional length of exhaust pipes for diesel engine exhaust pipe with insulation and aluminium clading, along with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required for istallation.<br>

25

-

-

... More
DATA & TELEPHONE NETWORK

-

-

-

... More
od363140/2020_2021 : Supplying, Installation, Testing & Commissioning of 6-core Multi mode OM3 metallic armored Fiber cable as per ISO/IEC-11801, Shall be able to meet Gigabit & 10 Gigabit Ethernet performance up to 300 meters requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10G Base-X) Tensile load should be 4000 Newton or higher and crush resistance should be 4000 Newton or higher ,The attenuation @ 850 nm should be ≤ 2.7 (Max) db/Km and @ 1300 nm should be ≤ 0.7 (Max) dB/Km, the fiber construction can be unitube or multitube, but tensile and crush resistance parameters should be matched, the jacket shall be FRLSZH complete in all respect.

150

-

-

... More
od363143/2020_2021 : Supply, Installation, Testing & Commissioning of 16 port 10/100/1000 Base-T Manegable L3 Core Switch with 16 port 10G fibre combo ports with SFP modules loaded as required and all related termination accessories as per vendor specific System requirement. 16 Port Switch

1

-

-

... More
od363144/2020_2021 : Supplying & Fixing of Fiber Optic Patch Cable (LC-LC), 3 Mtrs. Long, ISO/IEC-11801-OM3 50μ Duplex, LSZH,All patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801,Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50μ,Shall support network line speeds up to 10 Gbps.Shall have LC-LC Connector connectors at the ends complete in all respect..

10

-

-

... More
od363145/2020_2021 : Supply & Fixing of OM3 50/125μ Type Pigtails of ISO/IEC-11801-OM3 Pigtails with LC Type Connectors,pigtails for terminating fibers on the FOPP complete in all respect.

24

-

-

... More
od363146/2020_2021 : Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 24 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber..

18

-

-

... More
od363147/2020_2021 : Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.

1

-

-

... More
od363148/2020_2021 : Supplying & Fixing of Category 6 UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. Blue UTP Cable, 2 Meter complete in all respect. Jacket -LSZH .

150

-

-

... More
od363150/2020_2021 : Supplying & Fixing of Single Faceplate Shall be Duplex Port (RJ45) square plate, dimension as per commercially available modular office furniture.Shall have spring shuttered front access for preventing ingress of dust,Shall be supplied with Gang Box of the same size by System Integrator complete in all respect. .

70

-

-

... More
od363151/2020_2021 : Supplying & Fixing of UTP Jack Panel, loaded with 24 nos UTP ports for Non-PCB based IO Jacks (RJ45, TIA-568C Category-6, Shall have integrated bonding bar or other mechanism for grounding, Shall be loaded with individually replaceable 24 nos. Category-6 certification by Jacks complying with TIA-568.C.2 , Shall be having a 6 port module construction for better cable dressing at the rear, the jacks shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable complete in all respect.

4

-

-

... More
od363155/2020_2021 : Supplying & Fixing of Non- PCB based Information Outlet (I/O) RJ45, Tolless Termination TIA-568C Category-6, Termination of Catergory-6 UTP Cable, UL listed ,Shall conform to Category-6 as per the EIA/TIA-568C.2,Shall support network line speeds up to 1 Gbps, Shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable, Shall have minimum duraility of 950 or Above mating cycles and 200 termination cycles. Certified by independent labs like ETL/GHMT/3P for compliance to EIA/TIA-568C.2 complete in all respect..

48

-

-

... More
od363168/2020_2021 : Supplying & Fixing of Category 6, UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. UTP Cable will be 1.0 mtr. complete in all respect. Jacket - LSZH .

96

-

-

... More
od363177/2020_2021 : SSupplying Installation testing and Commissioning of 24 port 10/100/1000BASE-T ports and 2x1G SFP+<br>uplink ports, layer 2 from day1 having static & RIP ,stackable upto 10 switches, should support external<br>redundant power supply, certified , each switch should be provided with stacking port/cable complete in<br>all respect .<br>

6

-

-

... More
od363179/2020_2021 : Supplying, Installation, Testing & Commissioning of 24 port 10/100/1000BASE-T POE ports and 2x1G<br>SFP+ uplink ports layer 2 from day1 having static & RIP , stackable upto 10 switches, should support<br>external redundant power supply, certified EAL3 , each switch should be provided with stacking<br>port/cable.

8

-

-

... More
od363180/2020_2021 : Supplying Installation testing and Commissioning of SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1m in length complete in all respect.

2

-

-

... More
od363182/2020_2021 : Supplying Installation testing and Commissioning of Small Form Factor Pluggable 1 Gigabit Ethernet (SFP+) SR Optics

1

-

-

... More
od363186/2020_2021 : Supplying Installation testing and Commissioning of SFP 1000Base-T 10/100/1000 Copper Transceiver Module for up to 100m transmission on Cat6 complete in all respect.

20

-

-

... More
od363190/2020_2021 : Supplying & Fixing of Floor Standing Network/Server Rack - 42U / 800w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 42U/800d Front MS Door Perforated honeycomb 42U/800w Rear MS Door Split Perforated honeycomb 42U/800wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U Shelf, Stationery 700mm N/W PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 1U MS with Loops complete in all respect.

1

-

-

... More
od363192/2020_2021 : Supplying & Fixing of Floor Standing Network Rack - 22U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 22U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 22U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U complete in all respect.

6

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

3500

-

-

... More
EPABX SYSTEM

-

-

-

... More
od186279/2023_2024 : Supply installation testing and commissioning of- 6 line 2.8” (480 x 320) color display phones<br>- Up to 18 programmable keys with 6 self-label keys<br>- HD audio for handset and speaker with wideband codec (G.722,Opus)<br>- Full duplex speakerphone with wideband voice<br>- Dual Gigabit Ethernet ports

1

-

-

... More
od186282/2023_2024 : Supply installation testing and commissioning of IP Operator Console (It should be from same OEM of IP PBX to have full feature transparency)6 line 3.5” (240 x 320) color display phones<br> - Up to 64 programmable keys with 6 self-label keys<br> - HD audio for handset and speaker with wideband codec (G.722,Opus)<br> - Full duplex speakerphone with wideband voice<br> - Dual Gigabit Ethernet ports including all the necessary requirements for installation and commissioning.

1

-

-

... More
od186286/2023_2024 : Supply installation testing and commissioning of main cabinet rack mount type which fits in 19" cabinet with universal slot and power suply for the MCKTE with redundancy.

1

-

-

... More
od186290/2023_2024 : supply, installation,Testing and commissioning of basic IP phone with POE power, Handfree and display and one touch key

22

-

-

... More
od186302/2023_2024 : Supply Installation testing and commissioning of communication server equiped with the following:-Highly Scalable – Up to 15000 ports with single server,Server Redundancy - Active,500 - IP User License,01 PRI - Expandable,Automated Attendant,Audio Conference - 28 Party and Unified Communication, Click do dial, busy status indication, multi pary conference and Presence for all users

1

-

-

... More
VIDEO SURVEILIANCE SYSTEM (IP CCTV)

-

-

-

... More
od363216/2020_2021 : Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camera for true HD quality images, 2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,Snapshoot Support JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low light ONVIF compliant complete in all respect.

49

-

-

... More
od363218/2020_2021 : Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera c,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-40-50M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant .

3

-

-

... More
od363220/2020_2021 : Supply, installation, testing and commissioning of 2U Rack mount single chassis Network Video Recorder with dual Gb NIC, 1 DVI-I + HDMI + 1 Display Port, max 2 simultaneous monitors, RS-232/485 serial port, DVD, Server Operating System-Windows 10,Ubuntu Linux 16.04, Processor-Gen 4 Intel Core i3, Local Client Display Rate (FPS)Windows – 700 FPS (HD)Linux – 900 FPS (HD),High Performance, High Reliability IP Recorder. — Continuously records 300Mbps (Windows) & 450 Mbps (Linux)of video while hosting a local client, multiple remote clients and the web server on a single server,RAM-4 GB, 8 GB, 12 GB (Optional)solid-state operating system drive,USB-6 x USB 2.0, 2 x USB 3.0 high air flow cooling and hardware monitoring features ensure maximum uptime. keyboard and mouse, Professional Grade client and server software pre-installed and software updates. Access live and recorded video on multiple client PCs with free Windows, Mac or Linux client application. web server application is pre-installed on the server to access video through a web browser or free Mobile iPhone / iPad and Android apps. Maximum Storage Capacity 30TB & Maximum Hard Drive 3 Slot(Up to 10TB) Support Up to 64 IP Camera.

1

-

-

... More
od363222/2020_2021 : Supply, installation, testing and commissioning of Enterprise Class 6TB HDD. <br>

2

-

-

... More
od363224/2020_2021 : Supply, installation, testing and commissioning of Video Management System (VMS) software shall be used to view live and recorded video from capture cards and IP devices connected to local and wide area networks. The VMS software shall have a client/server-based architecture that can be configured as a standalone VMS system with the client software running on the server hardware and/or the client running on any network-connected TCP/IP workstation. Multiple client workstations shall be capable of simultaneously viewing live and/or recorded video from one or more servers. Multiple servers shall also be able to simultaneously provide live and/or recorded video to one or more workstations. The VMS server software shall also have the ability to be installed on an IP edge device—such as an IP camera or encoder that allows for 3rd party applications—allowing the device to serve as both a server and IP video recording device.The VMS shall not charge for the number of concurrent clients (min. 50 thick clients and 16 mobile clients to be provided along with VMS).

1

-

-

... More
od363226/2020_2021 : Supplying Installation testing and Commissioning of 24 port POE 10/100/1000BASE-T ports and 2x1G SFP+uplink ports, layer 2 from day1 having static & RIP ,stackable upto 10 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in<br>all respect .

7

-

-

... More
od363228/2020_2021 : Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); Memory: 4GB, NON-ECC, 1600MHZ; RAM: 4GB (1x4GB) Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit.

1

-

-

... More
od363230/2020_2021 : Supplying, Installation,Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect.

3

-

-

... More
od144477/2023_2024 : Supply laying and giving connections of Co-axial cables<br>

300

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
od363728/2020_2021 : Supply, Installation, testing and commissioning of digital signal processor with built in 10 input and 12 output and expandable upto 64 input and 60 output, front panel with OLED display, 4 or more GPIO conenctivity, 2 or more USB port, 4 or more Dante connectivity points, Selectable 48/96kHz sampling rates, built in event scheduler, processors should be ETL marked and comply with UL/CSA/CE safety requirements, FCC emission requirements, and shall be compliant with the RoHS directive etc complete required as per specifications.

1

-

-

... More
od363729/2020_2021 : Supply,Installation, testing and commissioning of IP55 rated 2-way wall speaker, Max power : 6 watt@8ohm, Sensitivity : 85dB, Crossover Frequency : 2.5KHz, LF driver : 3" or more, Frequency Range : 60 Hz - 20 kHz, Line Transformer Tappings : 20watt - 10watt, Max Sound Pressure : 100dB, Dispersion Horizontal : 100° or more, Vertical : 100° or more etc complete required as per specifications .

30

-

-

... More
od363730/2020_2021 : Supply, Installation, testing and commissioning of ceiling mount broadband speaker, 5" full range driver, Steel front grill with flame retardant materials, built in Steel fire protection dome, Line transfer tapping : 6watt - 3watt, Frequency Response : 90 Hz - 18 kHz, Max Sound Pressure : 90dB, should be comply with EN 61000-4-3:2001, EN 61000-4-1:2001, EN 60065:98 etc complete required as per specifications.

88

-

-

... More
od363738/2020_2021 : Supply, Installation, testing and commissioning of High power Hypex Class-D amplifier, High thermal efficiency, Integrated APC limiter, Transformer : Toroidal, Input connections : 4 x unbalanced on RCA with passthrough + 4 x balanced on euroblock, Input sensitivity : 0 dBV / 1 V or less, Input impedance : 22 kΩ, S/N ratio : >101 dB A weighted or better, THD : < 0.07 %, Frequency response : 50 – 20 kHz, Protection circuits : over current, over temperature, Channel separation : >68 dB @ 1 kHz, Power supply : 2Xswitching mode power supply, Cooling : temperature controlled fan, Bridged output power: 2x480W@100V etc complete required as per specifications.

1

-

-

... More
od363741/2020_2021 : Supply, Installation, testing and commissioning of touch based paging station, should be table mount / wall mount both, resolution : 1280 x 800 or better, Connectors : RJ45 ethernet, Power : PoE, can be expandable to make 16channel in one screen, comes with super cardioid paging microphone etc complete required as per specifications.

1

-

-

... More
od363744/2020_2021 : Supply, testing & commissioning of 2c x 1.5 sq.mm fire survival armoured cable 600/1000 Volt rated with class-2 Copper conductor having crosslinkable low smoke zero halogen insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner & outer sheath. The cable should meet fire performance circuit integrity test as per BS EN 50200 & BS 6387 CWZ (950 Deg. C for 3 hours). The cable should be LPCB certified to EN 61034-2, EN 60754-1, BS EN 50200 & BS 6387 CWZ. Outer sheath should be in red colour with Anti-rodent & LSZH properties including end terminators, saddles, clamps with screws etc for fixing on wall/ceiling or on cable trays complete as required.

3750

-

-

... More
od363745/2020_2021 : Supply Installation testing and commissioning of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers etc modules. Size 24U

1

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
od363830/2020_2021 : Supply Installation testing and Commissioning of Biometric Attendance Device fingerprint technology inside 1:10,000 user identification in 1 second,Anti-fraud features,Fake finger detection, duress finger, timed anti-pass back,Tough design,CPU: ARM® Cortex™-A9 core 1GHz.Linux Operating System, 1:N mode: 10,000 user (*3 templates each, including 1 duress),1:1 mode: 250,000 user IDs,1 Million transaction logs.Inputs/outputs: Wiegand In & Out,as per technical specification.

1

-

-

... More
od363831/2020_2021 : Supply, installation, testing and commissioning of Access Control Application Software for 32 Reader Capacity, and 1000 Card Holder Capacity, Basic GUI , TA Module with Alarm Module, T+ Module, 2-Nos Client Work Stations,Module for using SQL DB , -MULTI Site Module.

1

-

-

... More
od363832/2020_2021 : Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled 4 reader controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers & Magnetic Locks as per specification

2

-

-

... More
od363871/2020_2021 : Supply, testing and commissioning of iClass Smart card .

100

-

-

... More
od363872/2020_2021 : Supply, testing and commissioning of Exit Push Button

5

-

-

... More
od363873/2020_2021 : "Supply, installation, testing and commissioning of UL Listed Smart Card Reader fwith compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards.<br>Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry-standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards.<br>The reader should have audio transducer to provide various tone sequences to signify access granted, access denied, power up and diagnostics. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight.

2

-

-

... More
od363885/2020_2021 : Supply and Fixing of ''U'' Bracket with Accessories.

4

-

-

... More
od363886/2020_2021 : Supply, installation, testing and commissioning of Single Leaf Electro Magnetic Lock of Suitable Capacity(Min 600 lbs).

1

-

-

... More
od363890/2020_2021 : Supply, Fixing and Laying of 8 Core multi strand, copper, unarmoured Cable (between the every readers & the access controllers).

350

-

-

... More
od363891/2020_2021 : Supply and Fixing of ''L'' Bracket with Accessories.

2

-

-

... More
od363897/2020_2021 : Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity(Min 1200 lbs).

1

-

-

... More
od363899/2020_2021 : Supply, Fixing and Laying of 2 Core x 1.5 Sq mm, multi strand, copper, unarmoured cable (between the controller and EM Lock/Request to exit button).

350

-

-

... More
WI-FI SYSTEM

-

-

-

... More
od364062/2020_2021 : Obtaining and installing the Controller per AP Capacity License E LTU for the devices

10

-

-

... More
od364064/2020_2021 : Supplying, installation, testing and commissioning of Wireless Indoor AP should be Dual band 802.11ac wave2 supporting the legacy 802.11b/g/n standards also in the 2.4 and in the 802.11a/n in 5 GHz with Dual bands concurrent operations, should support 4x4 MU-MIMO in 5Ghz to communicate 4 devices simultaneously.should support minimum 02nos of Gigabit ethernet port (10/100/1000Mbps) and one USB port for IOT,Location services , Should support More than 500 concurrent users , Should support Hotspot2.0 (Passpoint ) compliant , Support aggregate data rate more than 2.0 Gbps , Support Mac Authentication for upto 1000 Mac per SSID

10

-

-

... More
SECURITY SYSTEM

-

-

-

... More
od364070/2020_2021 : Supply, Installation, Testing and Commissioning of Multi Zone Door frame metal detector, Multi-Zone - minimum 9 real detection zones, Auto Calibration (Automatically calibrates itself up to Environmental Conditions), These metal detectors have light indicators at side panels and control panel, Easy-to-mount and assemble walk through door frame metal detector<br>

2

-

-

... More
od364071/2020_2021 : Supply, Installation, Testing and Commissioning of Hand held metal detector, Detection of metal causes clear alarm noise and bright LED illumination, Low Battery Indication.

4

-

-

... More
od364072/2020_2021 : BOOM BARRIER. Supply, Installation, Testing and Commissioning of Motorized Vehicle Barrier complete with CAN bus communication standard interfaced Controller. It shall offer LCD Display & Graphic User Interface for easy control setting, integrated Two channel Loop Detector, Vario Boom of 6 Meters length with 1.3 Sec Opening/ Closing time and Maximum Power Consumption of 95 Watts.

2

-

-

... More
CABLE TRAY

-

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
od268535/2023_2024 : Supply & installation of 260 mm x 260 mm GI underfloor box suitable for two runs of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 266 mm x 266 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect.The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame<br>Two way junction box

3

-

-

... More
od268536/2023_2024 : Supply and installation of 358 mm x 358 mm GI under floor box suitable for three run of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 358 mm x 358 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect. The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame.<br>Three Way Junction box

3

-

-

... More
od268537/2023_2024 : Supply, laying and installation of following trapezoidal PVC floor ducting supplied in three meters per length including trunk connector, clamp, vertical/ horizontal bend etc in screed floor or on wall in line with EN 50085 including chasing and refilling the trench as per the route shown in the drawing and approved by consultant/ client at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of PVC trunk should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes Duct connector, Fastening Clamp along with associated accessories. <br>60 mm wide x 25 mm deep trapezoidal UPVC duct with 2 mm thick - 3 separate Parallel runs

35

-

-

... More
DATA &amp; TELEPHONE NETWORK

-

-

-

... More
od361597/2020_2021 : Supplying & Fixing of Non- PCB based Information Outlet (I/O) RJ45, Tolless Termination TIA-568C Category-6, Termination of Catergory-6 UTP Cable, UL listed ,Shall conform to Category-6 as per the EIA/TIA-568C.2,Shall support network line speeds up to 1 Gbps, Shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable, Shall have minimum duraility of 950 or Above mating cycles and 200 termination cycles. Certified by independent labs like ETL/GHMT/3P for compliance to EIA/TIA-568C.2 complete in all respect.

78

-

-

... More
od361657/2020_2021 : Supplying & Fixing of Single Faceplate Shall be Duplex Port (RJ45) square plate, dimension as per commercially available modular office furniture.Shall have spring shuttered front access for preventing ingress of dust,Shall be supplied with Gang Box of the same size by System Integrator complete in all respect.

57

-

-

... More
od361650/2020_2021 : Supplying & Fixing of UTP Jack Panel, loaded with 24 nos UTP ports for Non-PCB based IO Jacks (RJ45, TIA-568C Category-6, Shall have integrated bonding bar or other mechanism for grounding, Shall be loaded with individually replaceable 24 nos. Category-6 certification by Jacks complying with TIA-568.C.2 , Shall be having a 6 port module construction for better cable dressing at the rear, the jacks shall have RJ-45 type connector with bend limiting and strain relief boot for securing IDC contacts from external forces and for maintaining the bend radius of the cable complete in all respect.

12

-

-

... More
od361680/2020_2021 : Supplying & Fixing of Category 6, UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. UTP Cable will be 1.0 mtr. complete in all respect. Jacket - LSZH .

226

-

-

... More
od361712/2020_2021 : Supplying & Fixing of Category 6 UTP patch cords shall be constructed of 24-27 AWG unshielded twisted pair stranded copper cable with an enhanced performance modular plug at each end. Patch cord cable shall be offered in multiple colored UTP cable for design flexibility with a clear strain relief boot on each modular plug. All patch cords shall be compatible with both T568A and T568B wiring schemes. Blue UTP Cable, 2 Meter complete in all respect. Jacket -LSZH .

130

-

-

... More
od361722/2020_2021 : Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 24 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber.<br>

2

-

-

... More
od361723/2020_2021 : Supplying & Fixing of Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos of LC couplers (OM3) with all accessories complete in all respect. Pigtails Should Complie to ITU-G657.B-Bend insestive fiber. <br>

4

-

-

... More
od361726/2020_2021 : Supplying & Fixing of Fiber Optic Patch Cable (LC-LC), 3 Mtrs. Long, ISO/IEC-11801-OM3 50μ Duplex, LSZH,All patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801,Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50μ,Shall support network line speeds up to 10 Gbps.Shall have LC-LC Connector connectors at the ends complete in all respect.<br>

4

-

-

... More
od361727/2020_2021 : Supply & Fixing of OM3 50/125μ Type Pigtails of ISO/IEC-11801-OM3 Pigtails with LC Type Connectors,pigtails for terminating fibers on the FOPP complete in all respect.<br>

24

-

-

... More
od361740/2020_2021 : Supplying, Installation, Testing & Commissioning of, 6-core Multi mode OM3 metallic armored Fiber cable as per ISO/IEC-11801, Shall be able to meet Gigabit & 10 Gigabit Ethernet performance up to 300 meters requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10G Base-X) Tensile load should be 4000 Newton or higher and crush resistance should be 4000 Newton or higher ,The attenuation @ 850 nm should be ≤ 2.7 (Max) db/Km and @ 1300 nm should be ≤ 0.7 (Max) dB/Km, the fiber construction can be unitube or multitube, but tensile and crush resistance parameters should be matched, the jacket shall be FRLSZH complete in all respect.

100

-

-

... More
od361743/2020_2021 : Supply, Installation, Testing and commissioning of 16 port 10/100/1000 Base-T Manegable L3 Core Switch with 16 port 10G fibre combo ports with SFP modules loaded as required and all related termination accessories as per vendor-specific System requirement. 16 Port Switch

3

-

-

... More
od361884/2020_2021 : Supplying Installation testing and Commissioning of 24 port 10/100/1000BASE-T ports and 2x1G SFP+ uplink ports, layer 2 from day1 having static & RIP ,stackable upto 10 switches, should support external redundant power supply, certified , each switch should be provided with stacking port/cable complete in all respect .

7

-

-

... More
od361903/2020_2021 : Supplying, Installation, Testing & Commissioning of 24 port 10/100/1000BASE-T POE ports and 2x1G SFP+ uplink ports layer 2 from day1 having static & RIP , stackable upto 10 switches, should support external redundant power supply, certified EAL3 , each switch should be provided with stacking port/cable.

6

-

-

... More
od361942/2020_2021 : Supplying Installation testing and Commissioning of SFP+ 10 Gigabit Ethernet Direct Attach Copper (twinax copper cable) 1m in length complete in all respect. <br>

2

-

-

... More
od363181/2020_2021 : Supplying Installation testing and Commissioning of Small Form Factor Pluggable 1 Gigabit Ethernet (SFP+) SR Optics.<br>

1

-

-

... More
od363185/2020_2021 : Supplying Installation testing and Commissioning of SFP 1000Base-T 10/100/1000 Copper Transceiver Module for up to 100m transmission on Cat6 complete in all respect.<br>

24

-

-

... More
od363189/2020_2021 : Supplying & Fixing of Floor Standing Network/Server Rack - 42U / 800w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 42U/800d Front MS Door Perforated honeycomb 42U/800w Rear MS Door Split Perforated honeycomb 42U/800wFan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Vertical Cable manager 80mmW 42U Shelf, Stationery 700mm N/W PDU 12Sockets 5/15Amps with MCB Mounting Hardware (Pkt. Of 20) earthing Kit 150mmH Cable manager 1U MS with Loops complete in all respect.<br>

1

-

-

... More
od363191/2020_2021 : Supplying & Fixing of Floor Standing Network Rack - 22U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 22U/800d Front MS Door perforated honeycomb 22U/600w Rear MS Door (Fully Perforated - Mesh) 22U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, Stationery 475mm N/W PDU 7Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Vertical Cable Channel 50mmW 22U complete in all respect.

20

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

3000

-

-

... More
EPABX SYSTEM

-

-

-

... More
od185210/2023_2024 : supply, installation,Testing and commissioning of basic IP phone with POE power, Handfree and display and one touch key

45

-

-

... More
od185228/2023_2024 : Supply installation testing and commissioning of IP Operator Console (It should be from same OEM of IP PBX to have full feature transparency)6 line 3.5” (240 x 320) color display phones<br> - Up to 64 programmable keys with 6 self-label keys<br> - HD audio for handset and speaker with wideband codec (G.722,Opus)<br> - Full duplex speakerphone with wideband voice<br> - Dual Gigabit Ethernet ports including all the necessary requirements for installation and commissioning.

1

-

-

... More
od185229/2023_2024 : Supply installation testing and commissioning of- 6 line 2.8” (480 x 320) color display phones<br>- Up to 18 programmable keys with 6 self-label keys<br>- HD audio for handset and speaker with wideband codec (G.722,Opus)<br>- Full duplex speakerphone with wideband voice<br>- Dual Gigabit Ethernet ports

9

-

-

... More
od185256/2023_2024 : Supply installation testing and commissioning of main cabinet rack mount type which fits in 19" cabinet with universal slot and power suply for the MCKTE with redundancy.

1

-

-

... More
od185258/2023_2024 : Supply Installation testing and commissioning of communication server equiped with the following:-Highly Scalable – Up to 15000 ports with single server,Server Redundancy - Active,500 - IP User License,01 PRI - Expandable,Automated Attendant,Audio Conference - 28 Party and Unified Communication, Click do dial, busy status indication, multi pary conference and Presence for all users

1

-

-

... More
VIDEO SURVEILIANCE SYSTEM (IP CCTV)

-

-

-

... More
od363215/2020_2021 : Supplying, installation, testing and commissioning of 2 megapixels resolution Network Dome Camera for true HD quality images, 2.8 – 12 mm varifocal lens,True Day/Night (TDN) functionality for true color image ,Motion Detection 4 Zones, Multi- Level Sensitivity Privacy Zones 4 Zones,Snapshoot Support JPEG format Password Protection Support Character Display Support(Channel /Date) ONVIF Yes,IR Illumination20-30M IR illuminators for clear images in low light conditions Wide Dynamic Range 3D noise reduction for sharper images and lower bandwidth use in low light ONVIF compliant complete in all respect.<br>

53

-

-

... More
od363217/2020_2021 : Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera camera,Imager 1/2.8”SONY 2.43 mega low illumination CMOS,Video Compression. .H.264/MJPEG,Day/Night .Mechanical ICR,Minimum Illumination-0Lux/F1.4(IR ON) IR Illumination-40-50M,,Electronic Shutter-Auto/Manual(1/25~1/10000) Lens 2.8 – 12 mm varifocal lens,Resolution Main-stream:D1/Q1080P(960*540)/HD720P/ HD1080P 1-25/30fps,Digital Noise Reduction-3D,Wide Dynamic Range-Digital WDR Motion Detection -4 Zones, Multi- Level Sensitivity,Privacy Zones-4 Zones,Snapshoot-Support JPEG format,Password Protection-Support,Character Display-Support(Channel /Date).Regulatory Emissions-FCC Part 15 CE: EN55022,Immunity -CE: EN50130-4,IP Rating- IP66 rated enclosure to protect against dust and water damage ONVIF compliant .<br>

4

-

-

... More
od363219/2020_2021 : Supply, installation, testing and commissioning of 2U Rack mount single chassis Network Video Recorder with dual Gb NIC, 1 DVI-I + HDMI + 1 Display Port, max 2 simultaneous monitors, RS-232/485 serial port, DVD, Server Operating System-Windows 10,Ubuntu Linux 16.04, Processor-Gen 4 Intel Core i3, Local Client Display Rate (FPS)Windows – 700 FPS (HD)Linux – 900 FPS (HD),High Performance, High Reliability IP Recorder. — Continuously records 300Mbps (Windows) & 450 Mbps (Linux)of video while hosting a local client, multiple remote clients and the web server on a single server,RAM-4 GB, 8 GB, 12 GB (Optional)solid-state operating system drive,USB-6 x USB 2.0, 2 x USB 3.0 high air flow cooling and hardware monitoring features ensure maximum uptime. keyboard and mouse, Professional Grade client and server software pre-installed and software updates. Access live and recorded video on multiple client PCs with free Windows, Mac or Linux client application. web server application is pre-installed on the server to access video through a web browser or free Mobile iPhone / iPad and Android apps. Maximum Storage Capacity 30TB & Maximum Hard Drive 3 Slot(Up to 10TB) Support Up to 64 IP Camera.<br>

1

-

-

... More
od363221/2020_2021 : Supply, installation, testing and commissioning of Enterprise Class 6TB HDD.<br>

1

-

-

... More
od363223/2020_2021 : Supply, installation, testing and commissioning of Video Management System (VMS) software shall be used to view live and recorded video from capture cards and IP devices connected to local and wide area networks. The VMS software shall have a client/server-based architecture that can be configured as a standalone VMS system with the client software running on the server hardware and/or the client running on any network-connected TCP/IP workstation. Multiple client workstations shall be capable of simultaneously viewing live and/or recorded video from one or more servers. Multiple servers shall also be able to simultaneously provide live and/or recorded video to one or more workstations. The VMS server software shall also have the ability to be installed on an IP edge device—such as an IP camera or encoder that allows for 3rd party applications—allowing the device to serve as both a server and IP video recording device.The VMS shall not charge for the number of concurrent clients (min. 50 thick clients and 16 mobile clients to be provided along with VMS).<br>

1

-

-

... More
od363225/2020_2021 : Supplying, Installation, Testing & Commissioning of 24 port 10/100/1000BASE-T POE ports and 2x1G SFP+ uplink ports layer 2 from day1 having static & RIP , stackable upto 10 switches, should support external redundant power supply, certified EAL3 , each switch should be provided with stacking port/cable

3

-

-

... More
od363227/2020_2021 : Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); Memory: 4GB, NON-ECC, 1600MHZ; RAM: 4GB (1x4GB) Non-ECC DDR3 1600MHz SDRAM Memory; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; 20" TFT Monitor; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit.<br>

1

-

-

... More
od363229/2020_2021 : Supplying, Installation,Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect. <br>

1

-

-

... More
od363231/2020_2021 : Supplying, Installation,Testing & Commissioning of 4-pair Unshielded twisted pair with a cross filler (+), meeting Category 6 standards as per TIA-568C.2, The cable should be tested till 250 MHz , Shall be Fire-Retardant, Low-Smoke & Zero-Halogen as per IEC 60332-1, IEC 61034-2 & IEC 60754-1 respectively. <br>

1260

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
od363725/2020_2021 : Supply, Installation, testing and commissioning of IP55 rated 2-way wall speaker, Max power : 6 watt@8ohm, Sensitivity : 85dB, Crossover Frequency : 2.5KHz, LF driver : 3" or more, Frequency Range : 60 Hz - 20 kHz, Line Transformer Tappings : 20watt - 10watt, Max Sound Pressure : 100dB, Dispersion Horizontal : 100° or more, Vertical : 100° or more etc complete required as per specifications.<br>

29

-

-

... More
od363726/2020_2021 : Supply, Installation, testing and commissioning of ceiling mount broadband speaker, 5" full range driver, Steel front grill with flame retardant materials, built in Steel fire protection dome, Line transfer tapping : 6watt - 3watt, Frequency Response : 90 Hz - 18 kHz, Max Sound Pressure : 90dB, should be comply with EN 61000-4-3:2001, EN 61000-4-1:2001, EN 60065:98 etc complete required as per specifications.<br>

72

-

-

... More
od363731/2020_2021 : Supply, Installation, testing and commissioning of digital signal processor with built in 10 input and 12 output and expandable upto 64 input and 60 output, front panel with OLED display, 4 or more GPIO conenctivity, 2 or more USB port, 4 or more Dante connectivity points, Selectable 48/96kHz sampling rates, built in event scheduler, processors should be ETL marked and comply with UL/CSA/CE safety requirements, FCC emission requirements, and shall be compliant with the RoHS directive etc complete required as per specifications.<br>

1

-

-

... More
od363735/2020_2021 : Supply, Installation, testing and commissioning of High power Hypex Class-D amplifier, High thermal efficiency, Integrated APC limiter, Transformer : Toroidal, Input connections : 4 x unbalanced on RCA with passthrough + 4 x balanced on euroblock, Input sensitivity : 0 dBV / 1 V or less, Input impedance : 22 kΩ, S/N ratio : >101 dB A weighted or better, THD : < 0.07 %, Frequency response : 50 – 20 kHz, Protection circuits : over current, over temperature, Channel separation : >68 dB @ 1 kHz, Power supply : 2Xswitching mode power supply, Cooling : temperature controlled fan, Bridged output power: 2x480W@100V etc complete required as per specifications.

1

-

-

... More
od363742/2020_2021 : Supply, Installation, testing and commissioning of touch based paging station, should be table mount / wall mount both, resolution : 1280 x 800 or better, Connectors : RJ45 ethernet, Power : PoE, can be expandable to make 16channel in one screen, comes with super cardioid paging microphone etc complete required as per specifications.

1

-

-

... More
od363746/2020_2021 : Supply, testing & commissioning of 2c x 1.5 sq.mm fire survival armoured cable 600/1000 Volt rated with class-2 Copper conductor having crosslinkable low smoke zero halogen insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner & outer sheath. The cable should meet fire performance circuit integrity test as per BS EN 50200 & BS 6387 CWZ (950 Deg. C for 3 hours). The cable should be LPCB certified to EN 61034-2, EN 60754-1, BS EN 50200 & BS 6387 CWZ. Outer sheath should be in red colour with Anti-rodent & LSZH properties including end terminators, saddles, clamps with screws etc for fixing on wall/ceiling or on cable trays complete as required.

3000

-

-

... More
od363747/2020_2021 : Supply Installation testing and comisioning of 19-inch Equipment Rack with standardized frame or enclosure for mounting multiple PA controllers, CD player, Amplifiers etc modules. Size 24U.

1

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
od363833/2020_2021 : Supply Installation testing and Commissioning of Biometric Attendance Device fingerprint technology inside 1:10,000 user identification in 1 second,Anti-fraud features,Fake finger detection, duress finger, timed anti-pass back,Tough design,CPU: ARM® Cortex™-A9 core 1GHz.Linux Operating System, 1:N mode: 10,000 user (*3 templates each, including 1 duress),1:1 mode: 250,000 user IDs,1 Million transaction logs.Inputs/outputs: Wiegand In & Out,as per technical specification.

2

-

-

... More
od363834/2020_2021 : Supply, installation, testing and commissioning of Access Control Application Software for 32 Reader Capacity, and 1000 Card Holder Capacity, Basic GUI , TA Module with Alarm Module, T+ Module, 2-Nos Client Work Stations,Module for using SQL DB , -MULTI Site Module.

1

-

-

... More
od363835/2020_2021 : Supply, Installation, testing and commissioning of Surface mounted Networkable multiprocessor controlled 4 reader controller capable of controlling multiple readers (IN/OUT) alongwith TCP/IP connectivity complete as per specifications. Control panel housed in MS Powder Coated Cabinet with Tamper Switch, Complete with power supply unit for Controllers & Magnetic Locks as per specification

2

-

-

... More
od363874/2020_2021 : Supply, testing and commissioning of iClass Smart card .<br>

100

-

-

... More
od363875/2020_2021 : Supply, testing and commissioning of Exit Push Button<br>

3

-

-

... More
od363876/2020_2021 : "Supply, installation, testing and commissioning of UL Listed Smart Card Reader fwith compatible support of weigand output, 13.56 MHz technology platform and complies with the ISO 15693 / 14443A standard for contact less smart card technology. Card reader must be configurable to read encrypted ISO14443A sectors using standard or custom read keys for Sign OUT Terminal. should be compatible with HID format cards.<br>Encryption,All RF data transmission between the card and reader should be encrypted using a secure algorithm. Industry-standard encryption techniques and advanced key management systems should be used to avoid the risk of compromised data or duplicated cards.<br>The reader should have audio transducer to provide various tone sequences to signify access granted, access denied, power up and diagnostics. Visually impaired cardholders can easily distinguish between access granted and access denied. High-intensity light bar should provide a clear visual status indication in red, green or amber, even in bright sunlight.

3

-

-

... More
od363887/2020_2021 : Supply and Fixing of ''L'' Bracket with Accessories.

2

-

-

... More
od363888/2020_2021 : Supply and Fixing of ''U'' Bracket with Accessories.

3

-

-

... More
od363889/2020_2021 : Supply, installation, testing and commissioning of Single Leaf Electro Magnetic Lock of Suitable Capacity(Min 600 lbs).

1

-

-

... More
od363893/2020_2021 : Supply, Fixing and Laying of 8 Core multi strand, copper, unarmoured Cable (between the every readers & the access controllers).

350

-

-

... More
od363895/2020_2021 : Supply, installation, testing and commissioning of Double Leaf Electro Magnetic Lock of Suitable Capacity(Min 1200 lbs).

2

-

-

... More
od363898/2020_2021 : Supply, Fixing and Laying of 2 Core x 1.5 Sq mm, multi strand, copper, unarmoured cable (between the controller and EM Lock/Request to exit button). <br>

350

-

-

... More
WI-FI SYSTEM

-

-

-

... More
od364058/2020_2021 : Obtaining and installing the Controller per AP Capacity License E LTU for the devices

11

-

-

... More
od364060/2020_2021 : Supplying, installation, testing and commissioning of Wireless Indoor AP should be Dual band 802.11ac wave2 supporting the legacy 802.11b/g/n standards also in the 2.4 and in the 802.11a/n in 5 GHz with Dual bands concurrent operations, should support 4x4 MU-MIMO in 5Ghz to communicate 4 devices simultaneously.should support minimum 02nos of Gigabit ethernet port (10/100/1000Mbps) and one USB port for IOT,Location services , Should support More than 500 concurrent users , Should support Hotspot2.0 (Passpoint ) compliant , Support aggregate data rate more than 2.0 Gbps , Support Mac Authentication for upto 1000 Mac per SSID , including Poe Injector. br>

11

-

-

... More
SECURITY SYSTEM

-

-

-

... More
od364074/2020_2021 : Supply, Installation, Testing and Commissioning of Multi Zone Door frame metal detector, Multi-Zone - minimum 9 real detection zones, Auto Calibration (Automatically calibrates itself up to Environmental Conditions), These metal detectors have light indicators at side panels and control panel, Easy-to-mount and assemble walk through door frame metal detector<br>

2

-

-

... More
od364075/2020_2021 : Supply, Installation, Testing and Commissioning of Hand held metal detector, Detection of metal causes clear alarm noise and bright LED illumination, Low Battery Indication.

4

-

-

... More
VIDEO CONFERENCING SYSTEM

-

-

-

... More
od226628/2023_2024 : Supply installation testing and commissioning of Swivel wall mount for the 75" and 98" display devices with all the accessories and fittings required for the mounting and commissioning.

3

-

-

... More
od226629/2023_2024 : Supply installation testing and commissioning of 98 Inch Display, Operation Hr 24/7, IPS Panel / D LED, Resolution (H × V) 3840 × 2160 pixels, Brightness Minimum 550 cd/㎡, Minimum 4 HDMI, 1 DP, Min 2 nos USB 2.0 , 1 USB C 3.0, HDMI Out, Inbuilt Speaker of Minimum 20 W, Control LAN / RS 232, Support HDMI 1.4 & 2.0 , Support Optional Inbuilt OPS Slot. Certification BIS.

1

-

-

... More
od226633/2023_2024 : Supply, installation ,testing and commissioning of 55" LED 4k display with all fittings and accessories.

3

-

-

... More
od226666/2023_2024 : Supply ,installation, testing and commissioning of Wall mount for the PTZ camera with 12x optical zoom with all fittings and accessories.

1

-

-

... More
od226667/2023_2024 : Supply,installation,testing and commission of Full HD PTZ Camera supporting 1080p at 60 Frames per Second, minimum 12X Optical Zoom, with IP, HDMI, USB 3.0 & 3G-SDI Output, min 256 Presets, RS232/422 and IP Controls, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle , Minimum FoV 72 deg, Should support PoE & should be compatible with Virtual USB Driver. OEM should be BIS, CE,RoHS & FCC Certified

1

-

-

... More
od226687/2023_2024 : Supply ,installation ,testing and commissioning of Swivel wall mount for 55'' led wall display with all fittings and accessories.

3

-

-

... More
od254450/2023_2024 : Supply Installation testing & commissioning of 75 inch interactive 4K display with Brightness(w/Protection Glass) : 330 cd/m²,Touch Type : IR, Multi Touch Point : Max 20 points / Max 10 writing,Interface : HDMI (3), RGB / Audio In,RS232C In, RJ45,USB 2.0 (3, Front : 2ea, Bottom side: 1ea Only for software update), USB 3.0 (3), Touch Out(USB2.0,B Type) (2),HDMI (1), Optical Output / Audio Out with all the necessary fittings and cables for connection.

2

-

-

... More
VEDIO SWITCHING SYSTEM

-

-

-

... More
od226721/2023_2024 : Supply, installation, testing and commissioning of 3x1 4K60 USB–C/HDMI Switcher with all fittings and accessories

1

-

-

... More
od226723/2023_2024 : Supply, installation, testing and commissioning HDMI Receiver with all fittings and accessories.

2

-

-

... More
od226724/2023_2024 : Supply, installation, testing, and commissioning of HDMI Transmitter with all fittings and accessories

2

-

-

... More
od226725/2023_2024 : Supply, installation, testing and commissioning of Wireless Presentation System with all fittings and accessories.

1

-

-

... More
od226726/2023_2024 : Supply, installation, testing and commissioning of Cable cubby with all fittings and accessories.

1

-

-

... More
AUDIO SYSTEM

-

-

-

... More
od227111/2023_2024 : Supply, installation, testing and commissioning of Delegate Microphone Unit with all fittings and accessories.

12

-

-

... More
od227116/2023_2024 : Supply, installation, testing and commissioning of Powered Wall Speakers with all fittings and accessories.

1

-

-

... More
od227117/2023_2024 : Supply, installation, testing and commissioning of Digital Signal Processor with built-In Automatic mixing Console, Ducker dodger, Optional feedback elimination, Echo elimination, Noise elimination Module or better, Should have 08 AEC Mic/Line Inputs, 08 Line outputs or better, Should have Built-in bidirectional USB audio interface for soft codec conferencing solutions , Built-in Camera tracking functionality, Sampling rate of 48Khz or better with Quantization of 24bits or better, Analog/Digital Dynamic range 114dB or better with Digital/Analog Dynamic range 120dB or better etc, 8 Port freely configurable GPIO or better, Ethernet port for configuration and should be configurable thru software,All Complete.

1

-

-

... More
od227118/2023_2024 : Supply, installation, testing and commissioning of Power repeater for up to 30 units with all fittings and accessories.

1

-

-

... More
od227119/2023_2024 : Supply, installation, testing and commissioning of Central controller unit with fittings and accessories.

1

-

-

... More
od227120/2023_2024 : Supply, installation, testing and commissioning of Chairman Microphone Unit with all fittings and accessories.

2

-

-

... More
BULK AND PATCH CABLE-ON ACTUALS

-

-

-

... More
od227411/2023_2024 : Supply, installation, testing, and commissioning of HDMI Patch Cable 6 ft with all fittings and accessories

6

-

-

... More
od227724/2023_2024 : Supply, installation, testing and commissioning of USB–C (M) to USB–C (M) 35ft cable with all fittings and accessories.

1

-

-

... More
od240040/2023_2024 : Supply, installation, testing and commissioning of 14 AWG Speaker Cable with all fittings and accessories.

450

-

-

... More
od240041/2023_2024 : Supply, installation, testing and commissioning of STP cable with fittings and accessories.

250

-

-

... More
od240042/2023_2024 : Supply, installation, testing and commissioning of Audio Sterio / Control Cable with all fittings and accessories.

220

-

-

... More
od240043/2023_2024 : Supply, installation, testing and commissioning of Microphone Cable with all fittings and accessories.

380

-

-

... More
MOUNTING & ACCESSORIES

-

-

-

... More
od227747/2023_2024 : Supply, installation, testing and commissioning of Equipment Rack -600x800 with all fittings and accessories.

1

-

-

... More
CONTROLL SYSTEM(OPTIONAL)

-

-

-

... More
od227759/2023_2024 : Supply, installation, testing and commissioning of Base Station with all fittings and accessories.

1

-

-

... More
od227760/2023_2024 : Supply, installation, testing and commissioning of Docking Station Sleeve with all fittings and accessories.

1

-

-

... More
od227761/2023_2024 : Supply, installation, testing and commissioning of Wireless access point with all fittings and accessories.

1

-

-

... More
od227762/2023_2024 : Supply, installation, testing and commissioning of 28 Port Network Switch with all fittings and accessories.

1

-

-

... More
od227763/2023_2024 : Supply, installation, testing and commissioning of 10.2" Wireless Ipad with all fittings and accessories.

1

-

-

... More
od227764/2023_2024 : Supply, installation, testing and commissioning of Master space control processor with all fittings and accessories.

1

-

-

... More
CABLE TRAY

-

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
od268539/2023_2024 : Supply & installation of 260 mm x 260 mm GI underfloor box suitable for two runs of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 266 mm x 266 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect.The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame<br>Two way junction box

12

-

-

... More
od268540/2023_2024 : Supply and installation of 358 mm x 358 mm GI under floor box suitable for three run of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 358 mm x 358 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect. The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame.<br>Three Way Junction box

10

-

-

... More
od268541/2023_2024 : Supply, laying and installation of following trapezoidal point load tested PVC floor ducting supplied in three meters per length including trunk connector, clamp, vertical/ horizontal bend etc in screed floor or on wall in line with EN 50085 including chasing and refilling the trench as per the route shown in the drawing and approved by consultant/ client at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of PVC trunk should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes Duct connector, Fastening Clamp along with associated accessories. <br>90 mm wide x 35 mm deep trapezoidal UPVC duct with 2 mm thick - 3 separate Parallel runs

60

-

-

... More
od268542/2023_2024 : Supply, laying and installation of following trapezoidal PVC floor ducting supplied in three meters per length including trunk connector, clamp, vertical/ horizontal bend etc in screed floor or on wall in line with EN 50085 including chasing and refilling the trench as per the route shown in the drawing and approved by consultant/ client at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of PVC trunk should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes Duct connector, Fastening Clamp along with associated accessories. <br>60 mm wide x 25 mm deep trapezoidal UPVC duct with 2 mm thick - 3 separate Parallel runs

50

-

-

... More
od268543/2023_2024 : Supply and activating Internet firewall of Threat Protection Through put of 700 Mbps or Better,IPS Throughput of 1.4 Gbps or Better, Firewall Throughput of 10/10/6 Gbps or Better, Firewall Throughput (Packets Per Second) of 9 Mbps or Better, with Concurrent Sessions (TCP) of 700000, Firewall Policies, Client-to-Gateway IPsec VPN Tunnels of 200, and SSL-VPN Throughput/ Sessions including GE RJ45 WAN, DMZ Ports, GE RJ45 Internal Ports, USB Ports,Console Ports and storage of 64GB Or higher, complete as required.<br>

1

-

-

... More
EXTERNAL CCTV

-

-

-

... More
od363234/2020_2021 : Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera camera,Imager 1/2.8” Progressive Scan CMOS,Video Compression. .H.264/MJPEG,Day/Night-IR Cut Filter,Minimum Illumination-0Lux/F1.4(IR ON) IR Range-Up to 50 Meter,Electronic Shutter-Auto/Manual(1/25~1/10000), Lens 2.8 to 12 mm Motorized zoom Lens,Resolution Main-1920x1080p,Digital Noise Reduction-3D,Wide Dynamic Range-120db, Behavior Analysis-Line crossing detection, intrusion detection, unattended baggage detection, object removal detection.Support Face Detection. Region of Interest Support 1 ROI per stream.Power Consumption and Current- 12 VDC, 1.2A, max. 14.5W PoE (802.3at, 42.5V to 57V), 0.5A to 0.1A, max. 16.5W.Protection Level IP67, IK10 TVS 2000V Lightning Protection, Surge Protection and Voltage Transient Protection.Regulatory UL, CE, FCC.Operating Conditions Temperature: -30 °C to +60 °C (-22 °F to +140 °F).Humidity: 95% or less.

14

-

-

... More
od363314/2020_2021 : Supply installation testing and commissioning of 19", 9U 500 MM wide x 550 MM Depth Wall Mount Networking Rack with Front Glass Door, Horizontal Cable M anager - 2 Nos, Cantilever Shelf - 1 No, Horizontal PDU 6X5Amps - 1 No, Cooling Fan - 2 Nos, Hardware Screws and all other required accessories

3

-

-

... More
od363325/2020_2021 : Supply, installation, testing & commissioning of 12 Port PoE+ Layer 2 Switch with 2 SFP slots 12 x 10/100/1000 Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at with PoE budget of 100W.

3

-

-

... More
od363332/2020_2021 : Supplying & Fixing of Fiber Optic 12 port LC style fully loaded Patch Panel (FOPP), 6U Rack Mount ,Shall have all accessories including coupler plates pre loaded with 12 Nos of LC couplers (OM3) with all accessories complete in all respect .

6

-

-

... More
od363337/2020_2021 : Supplying & Fixing of Fiber Optic Patch Cable (LC-LC), 3 Mtrs. Long, ISO/IEC-11801-OM3 50μ Duplex, LSZH,All patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801,Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50μ,Shall support network line speeds up to 10 Gbps.Shall have LC-LC Connector connectors at the ends complete in all respect..

12

-

-

... More
od363338/2020_2021 : Supply & Fixing of OM3 50/125μ Type Pigtails of ISO/IEC-11801-OM3 Pigtails with LC Type Connectors,pigtails for terminating fibers on the FOPP complete in all respect.

72

-

-

... More
od363345/2020_2021 : Supplying, Installation, Testing & Commissioning of 6-core Multi mode OM3 metallic armored Fiber cable as per ISO/IEC-11801, Shall be able to meet Gigabit & 10 Gigabit Ethernet performance up to 300 meters requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10G Base-X) Tensile load should be 800 Newton or higher and crush resistance should be 2000 Newton or higher , the fiber construction can be unitube or multitube, but tensile and crush resistance parameters should be matched, the jacket shall be LSZH complete in all respect.

650

-

-

... More
od363353/2020_2021 : Supply, installation, testing & commissioning of IP55 Outdoor Junction Box For Field Devices at camera side. JB must be of appropriate size to house different components as per CCTV system design confirming. The junction box shall be fixing along with weather proof clamping with pole as per site requirement.<br>

18

-

-

... More
od363366/2020_2021 : Supplying, Installation,Testing & Commissioning of 55 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect. <br>

1

-

-

... More
od363376/2020_2021 : Supply, installation, testing & commissioning of online 1KVA fully Microprocessor Based UPS System suitable for Single phase, AC 50 Hz. input supply comprising of following features.High Frequency PWM Inverter using IGBT Technology Manual by pass switch LCD disply SMF VRLA Batteires with 30 minutes back up time for full load including interconnecting cables Battery Rack. <br>

3

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

870

-

-

... More
14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

400

-

-

... More
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

450

-

-

... More
11.3.1 : Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

10

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

300

-

-

... More
od254543/2023_2024 : Supply of Aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish. Compatible for fitting external bullet camera with all accessories required for installation of camera. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to <br>the pole. 4M TOP Ø 76 MM dia.

10

-

-

... More
BUILDING MANAGEMENT SYSTEM

-

-

-

... More
od363708/2020_2021 : Supply installation testing commissioning of Intel i7 Processor ,32GB RAM , 1 TB SSD, SATA RAID controller(RAID 0,1,5), 4 gb Graphics card, Ethernet 1GB 2-PORT + Standard keyboard & mouse + Microsoft Windows 11 + 21/22 Inch LED Monitor with required all accessories

1

-

-

... More
od363748/2020_2021 : Supply, installation, testing & commissioning of the following Software for BMS: Web Based Graphical interface software based on MS Windows 10 / Latest. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be Industry Standard BACNET Open Protocol. System should be scalable. The software shall be open system architecture type which facilitates interoperability with other system over BACNET IP with complete control and monitoring functions. Software shall work in the WEB environment supporting HTML5, unlimited concurrent client users license on LAN / WEB. Software shall be certified and complying to BACnet Advanced Operator Workstation.

1

-

-

... More
od239957/2023_2024 : Supply installation testing commissioning of Intel i5 Processor ,16GB RAM , 1 GB SSD, 2-PORT Graphics card, Ethernet 1GB 2-PORT + Standard keyboard & mouse + Microsoft Windows 11 with required all accessories

1

-

-

... More
od239992/2023_2024 : Supply installation testing and commissioning of 32" LED monitors.

2

-

-

... More
DDC CONTROLLERS FOR R&D

-

-

-

... More
od239837/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Ground floor

1

-

-

... More
od259832/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-External Main Services

1

-

-

... More
od259833/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Internal Main services of Building

1

-

-

... More
od259834/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Fourth floor

1

-

-

... More
od259835/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Third floor

1

-

-

... More
od259836/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Second floor

1

-

-

... More
od259837/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-First floor

1

-

-

... More
DDC CONTROLLERS FOR CDC

-

-

-

... More
od239837/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Ground floor

1

-

-

... More
od259833/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Internal Main services of Building

1

-

-

... More
od259838/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Fifth floor

1

-

-

... More
od259834/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Fourth floor

1

-

-

... More
od259835/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Third floor

1

-

-

... More
od259836/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-Second floor

1

-

-

... More
od259837/2023_2024 : Supply installation testing and commissioning of DDC panel with MS Enclosure with terminals, transformers, and relays to house and appropriate controllers as per the I/O summary sheet, along with all the accessories required for installation and commissioning of panel and as per the direction of engineer in charge - DDC-First floor

1

-

-

... More
WEB SERVER ENGINES (NETWORK /SUPERVISORY CONTROLLERS)

-

-

-

... More
od239869/2023_2024 : Supply installation testing and commissioning of Supervisory Controller for connecting the Software ( PC ) to the DDC Controllers. <br>Important Note: <br>1) Vendors to quote this item only if applicable to complete the system<br>2) Vendors quoting for the following item shall provide one standby in the event the Supervisory Controller connected / managing the system fails. Standby controller shall be of capable of handling the project data points.

1

-

-

... More
INTEGRATION R&D BLOCK

-

-

-

... More
od239870/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Electrical Main panel

10

-

-

... More
od239871/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. VRF Integration.

1

-

-

... More
od239873/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. UPS

1

-

-

... More
od239874/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Lift

4

-

-

... More
od239875/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Energy meters

20

-

-

... More
od239993/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Cassette unit

13

-

-

... More
INTEGRATION CDC BLOCK

-

-

-

... More
od239870/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Electrical Main panel

10

-

-

... More
od239871/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. VRF Integration.

1

-

-

... More
od239873/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. UPS

1

-

-

... More
od239874/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Lift

5

-

-

... More
od239875/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Energy meters

45

-

-

... More
SENSORS & FIELD DEVICES

-

-

-

... More
od239883/2023_2024 : Supplying, installing, testing and commissioning of the Return air Combined Duct type Temperature sensor for AHU

90

-

-

... More
od239884/2023_2024 : Supplying, installing, testing and commissioning of the Diff. Pressure Switch Across Filter sensor.

12

-

-

... More
od240750/2023_2024 : Supply installation testing and commissioning of outdoor temperature( with +2% Accuracy) & humidity sensors complete as required as per the technical specification.

2

-

-

... More
EXTERNAL INTEGRATION

-

-

-

... More
od239911/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. DG Panel.

1

-

-

... More
od239912/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. CCTV Integration

2

-

-

... More
od239913/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Fire panel

2

-

-

... More
od239914/2023_2024 : "Supply, installation, testing & commissioning of Integrators for 3RD Party System Software Integration - BTL Certified<br>For open Protocols Integration units, to connect individual 3rd party microprocessor system controllers, the unit shall be capable of integrating all mentioned devices on BACnet, Modbus etc.as per distribution given below. System integration unit shall be of same make as of DDC Controller. Controllers with built-in integration ports are also acceptable, controller integration port can be used for 3rd party integration. Generator

3

-

-

... More
WIRING

-

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

7750

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

150

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
od239994/2023_2024 : Supply laying and terminating 2 core 1.5 sq mm twisted pair cable with all the accessories as required for laying through conduit/cable tray.

2790

-

-

... More
od239995/2023_2024 : Supply laying and terminating 2 core 1 sq mm screened cable with all the accessories as required for laying through conduit/cable tray.

7000

-

-

... More
od239996/2023_2024 : Supply laying and terminating 2 core 1 sq mm unscreened cable with all the accessories as required for laying through conduit/cable tray.

10000

-

-

... More
ELEVATORS CDC

-

-

-

... More
od361218/2020_2021 : Supply, Installation, Testing & Commissioning of 15 Passenger lift (1020Kg) electric traction, without machine room less having contract speed of 1.6 Meter per second serving different floors in the lift shaft of size 1950mm (W) x 2730mm (D), 1600 mm pit depth and 4000 mm overhead as per detailed specifications attached and as under complete with all the equipment and accessories. <br>Number of Landings (i.e.Stops) - Ground + 5th Floor = 6 Floors <br>Travel Height - 30 Mtrs (approx.)<br>No. Of Openings - 6 Stop & 6 Opening (all opening be on same side)<br>Drive System & Control - Micro Processor based VVVF or Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gearless Motor, Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required.<br>IONFUL Plasmacluster device, TFT LCD Cabin display, Remote Monitoring system<br>Operation - Microprocessor based triplex collective selective - (with/without-attendant)<br>Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system.<br>Car Enclosure: other details same as item no.1 from S.No. (x) to (xxiv) as above<br>Passenger lift as described as above<br>

3

-

-

... More
od361219/2020_2021 : Supply, Installation, Testing & Commissioning of 15 Pass. cum service lift-1020Kg electric traction, without machine room less having contract speed of 1.6 Meter per second serving different floors in the lift shaft of size 2350mm (W) x 2350mm (D), 1600 mm pit depth and 4000 mm overhead as per detailed specifications attached and as under complete with all the equipment and accessories. <br>Number of Landings (i.e. Stops) - Ground + 5th Floor = 6 Floors" Travel Height - 30.45 Mtrs (approx.) No. Of Openings - 6 Stop & 6 Opening (all opening be on same side) Drive System & Control - Micro<br>Processor based VVVF or Alternating Current Voltage Frequency (ACVF) with Closed Loop system with<br>Gearless Motor Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required. IONFUL Plasmacluster device, TFT LCD Cabin display, Remote Monitoring system <br>Operation - Microprocessor based simplex collective selective - (with/without - attendant) <br>Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system. <br>Car Enclosure: other details same as item no.1 from S.No. (x) to (xxiv) as above Passenger lift as described as above <br>

1

-

-

... More
ELEVATORS R&D

-

-

-

... More
od361220/2020_2021 : Supply, Installation, Testing & Commissioning of 15 Passenger lift (1020Kg) electric traction, without machine room less having contract speed of 1.6 Meter per second serving different floors in the lift shaft of size 1950mm (W) x 2700mm (D), 1600 mm pit depth and 4000 mm overhead as per detailed specifications attached and as under complete with all the equipment and accessories. <br>"Number of Landings (i.e. Stops) - Ground + 4th Floor = 5 Floors" Travel Height - 24 Mtrs (approx.) <br>No. Of Openings - 5 Stop & 5 Opening (all opening be on same side) Drive System & Control <br>Micro Processor based VVVF or Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gealess Motor Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required. IONFUL Plasmacluster device, TFT LCD Cabin display, Remote Monitoring system<br>Operation - Microprocessor based duplex collective selective - (with/without -attendant) <br>Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system. <br>Car Enclosure: Car Size ( WxDxH) - As per the Indian Standard Codes. Car height shall be minimum 2150mm Car door (Height x Width)mm -(2200 x 1100 )mm Minimum Must be Fully Automatic Power operated, central opening/Telescopic side opening, horizontal sliding stainless steel scratch resistant SS finish Car Ceiling - SS- Finish Hairline. Car Doors Finish - Stainless steel Hairline AISI441. <br>Car Floor - Granite Flooring Mirror - All the three side Sill - Aluminium profiles Car Operating Panel - To Be furnished by the tenderer.<br>Car Lighting - LED light, Minimum 50 lux on floor and on Car operating Panel. <br>Handrail - Round Bend Handrail Silver brushed stainless steel (ST4) at Rear<br>Wall.<br>Car Walls - Minimum 6mm Thick Decoration Skirting & Corners - Must be Anodised for weather protection Recess Flooring (for Owners) - 25mm Landing Doors: <br>Fully Automatic Power operated, central opening, horizontal sliding MS Doors with powder coating of approved shade. <br>Landing Door Size (WxD) mm – Minimum 1000 (Width) x 2000 (Height) Control & Fixtures Details - Landing display - 16-segment Car position and direction of travel display and Lift under maintenance display Emergency Alarm – Alarm with Rechargeable Sealed Maintenance Free batteries. <br>Over load warning - Audio/ Visual Overload warning indicator to be provided. <br>Voice Synthesizer in car - Floor and door open/close Voice Announcement <br>Car Display - 16-segment LED Dynamic Car Direction display & Digital position indicators Infra-red Light Curtain (Full Length) on Car doors - To be provided Auto Light/Fan Cutoff - Ventilation fan ON OFF switch with auto switch off feature. <br>Door open/ Door Close – Door open and Door Close buttons with Symbol markings. ARD operation Audio / Visual indication in car.<br>To be provided Emergency Alarm Button - Emergency Alarm button with Bell symbol & the same should be at a distinct distance from the call buttons. <br>Intercom - To be provided (i.e. 3-way intercom) Hall Buttons - To be provided as per the Tenderer Out of Service Mode - To be provided Attendant Operation - To be provided Machine Power Supply -3 x 415V /220V, 50Hz Acceptable Voltage Fluctuation - +10% to -15% Acceptable Frequency Fluctuation - +/-5% Rate of Acceleration/Deceleration M/s2 - < 0.5 meter per second square Jerk( m/sec3) - 1meter per second cube Horizontal Vibration X/Y (mPtP) - < 15mg (As per ISO 18738) Vertical Vibration Z - < 25 mg (As per ISO 18738) Airborne Noise Levels - 50 ± 3 dBa Airborne Noise level in Car (without Fan) - Max 60 dBa Airborne Noise level in front of closed Hoistway door (when car passing by) - Max 53 dBa Stopping Accuracy - ± 3mm Elongation - ± 20mm <br>Leveling Accuracy - ± 10mm Door Drive - Compact VVVF closed loop Car panel & Door panel thickness - Atleast 1.6 mm <br>Maximum Number of trips Per Hour - 180 Safety Features & Other Inclusions Door Protection <br>Multi beam infrared protection device so as to reverse the closing door in case of slight obstruction in the door way. <br>Anti nuisance - To Be provided <br>Fire Man Control – To Be provided Over Load detection Device - To Be provided <br>Buffers - Spring Buffers Safety Organisations P R I C E Governor - Electro-Mechanical type Safety governors for Car. <br>Safety Instructions - Do’s & Don’ts with emergency contact Numbers must be provided & displayed in the car Over travel protection - Terminal and final limit switches to be provided. <br>Controller / Drive / Motor Protection - Trip Device for Over current, Under Voltage and Over voltage than the rated capacity. + 10% · Motor overload / over torque · Instantaneous over current · Ground fault · Under voltage · Over voltage – 3 phase · Output & Input phase loss · Phase reversal · Output short circuit · Over speed · Spikes & Surges Protection with the Sudden surges/spikes in level in voltage along with shifting of neutral and earth leading to improper earthing (Must be provided as a separate kit.) ARD (Automatic Rescue Device) - ARD to be provided. (Detailed Literature of Make and working of ARD to be provided separately). <br>Fire Rating of Landing doors - Landing doors must have 1 hour fire resistance rating and Elevator supplier must provide the Fire-certificate for the same from Accredited laboratory. <br>Self adjustment & self Daigonastic - To be provided Intercom connection - Must be provided in 3-way Fascia Plates & Sill angles - Full height Fascia Plates and Sill angles to be provided (or as per the IS Code Guidelines) . Counter Weights - In case of non-metallic filler weights, the counterweight sections shall be totally enclosed in a metallic covering. <br>Voice Announcement – Voice announcement to announce the Floor position as well as door open/door close. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. Infra-red Light Curtain (Full Length) on Doors - To be provided – Multi beam infrared protection device so as to reverse the closing door in case of slight obstruction in the door way. Passenger lift as described as above <br>

2

-

-

... More
od361221/2020_2021 : Supply, Installation, Testing & Commissioning of 20 pass. cum service lift-1360Kg electric traction, without machine room less having contract speed of 1.6 Meter per second serving different floors in the lift shaft of size 2574mm (W) x 2750mm (D), 1800 mm pit depth and 4200 mm overhead as per detailed specifications attached and as under complete with all the equipment and accessories. <br>"Number of Landings (i.e. Stops) - Ground + 4th Floor = 5 Floors" <br>Travel Height - 25.45 Mtrs (approx.) No. Of Openings - 5 Stop & 5 Opening (all opening be on same side) <br>Drive System & Control – Micro Processor based VVVF or Alternating Current Voltage Frequency (ACVF) with Closed Loop system with Gealess Motor Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required. IONFUL Plasmacluster device, TFT LCD Cabin display, Remote Monitoring system <br>Operation - Microprocessor based simplex collective selective - (with/without -attendant) <br>Power: 415 Volts+10%, 3 Phase 4 wire 50 Hz AC system. <br>Car Enclosure: other details same as item no.1 from S.No. (x) to (xxiv) as above Passenger lift as described as above<br>

1

-

-

... More
Mechanized Car Parking

-

-

-

... More
od110859/2024_2025 : Supply, Installation, Testing & Commissioning of Mechanical Car parking System having the following Technical Specification: Type of system is Electromechanical twin car parking system, Overall System dimension having Length: 5000mm and Width: 2000mm. The suitable cars having height of 2000/1700/1550-SUV/HATCHBACK/SEDAN with enough clear height available at site having a lifting capacity of 2000kgs. enough clear pallet length shall be considered. The driving unit consists Electromotor of 1.5kW having traction chain, wire rope, DC magnetic braking and reducer inetgrated motor with a travelling speed of 3mtr/min. The power source required of 415V AC, 3phase, 50Hz and for lighting 220V AC ,1Ph, 50 Hz as supply and the operation shall through key switch operated hold to run operation including PCB card. The safety may consist of Pallet/Wheel stopper, Bottom car safety sensor, Geared motor with bike, Antenna type Limit switch to control the UP&DOWn movement and to control Over travel, Emergency stop button etc. ) Main column structure shape: C Channel 5) Size of column structure: 175 * 75,<br>Main column Anchoring Bolts size: M16*140mm ANCHOR FASTNER, Platform profile thickness:1.5 mm Thick Galvanized Corrugated Anti-Skid Type with Wheel Stopper, Section protection (MS/GI/Powder coated etc.): Hot Dip Galvanized with 275 GSM Platform, Structure. Pipe Covers are Galvanized.

45

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.