Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date15 Sep 2022
Closing Date10 Oct 2022
Tender Amount₹ 3,11,84,865 
Notes
Download

Costs

Summary

Road Resurfacing, Security Cabin, Landscaping And Other Allied Works In Sez And Non Sez At Kinfra Film, Video Park And It,ites Park, Kazhakoottam

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od100884/2022_2023 : Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of 6 mm coarse aggregate, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)

10

-

-

... More
od101088/2022_2023 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6 mm coarse aggregate, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

550

-

-

... More
16.82 : Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

200

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

100

-

-

... More
od102040/2022_2023 : Removing waste and cleaning the existing drain and disposing off the waste in suitable locations as instructed by the engineer in charge upto 50 m lead complete

770

-

-

... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

25

-

-

... More
14.1.2 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand)

50

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

493

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

50

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

38

-

-

... More
od323407/2021_2022 : Extra for additional lead upto 1 km

50

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

1990

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

45

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

50

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

10

-

-

... More
od323409/2021_2022 : Uprooting of existing tree roots of already cut trees complete

14

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

13

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

31

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

10

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

290

-

-

... More
od117493/2022_2023 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved dumping ground as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

169

-

-

... More
od323414/2021_2022 : Random rubble masonry with available hard stone in site for foundation and plinth including ;levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded ;stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)

289.8

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

101

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

36

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

35

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

74

-

-

... More
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)

10

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6828

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

370

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

131

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

85.47

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

25

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

19

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1104

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

5

-

-

... More
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

10

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

299

-

-

... More
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

12

-

-

... More
od323435/2021_2022 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level<br>Thermo - Mechanically Treated bars of grade Fe-500D or more

2064

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

31

-

-

... More
19.33 : Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

1

-

-

... More
19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg

3

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

45

-

-

... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

497

-

-

... More
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)

63

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

2

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

625

-

-

... More
od130639/2022_2023 : Providing and fixing square-mouth brick masonry chamber of size 300x300mm, depth of the chamber upto 1m and thickness of the wall 100 mm for hume pipe crossings with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. Work includes cement concrete foundation in the ratio 1:2:4 and inside plastering in CM 1:3 with thickness 12 mm

16

-

-

... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

7

-

-

... More
19.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5

7

-

-

... More
17.29 : Providing and fixing 100 mm sand cast Iron grating for gully trap.

200

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

82

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

486

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

4.5

-

-

... More
22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)

40

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

25

-

-

... More
od323440/2021_2022 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, wall dadoing, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints.<br>Size of Tile 600x600 mm

15.16

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

2650

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1480

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

178.97

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

41.66

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

20

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

14.55

-

-

... More
21.12.2 : Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50 micron aluminium tubular handle bar

4

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

2

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

2

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

2

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

2

-

-

... More
od323443/2021_2022 : Providing and fixing aluminium die cast body tubular type universal hydraulic<br>door closer (having brand logo with ISI, IS : 3564, embossed on the body, door<br>weight upto 35 kg and door width from 701mm to 1000mm), with double speed adjustment with necessary accessories<br>and screws etc. complete.

2

-

-

... More
od323444/2021_2022 : Providing and fixing parking barrier automatic boom gate of make Essl BG108 or equivalent of maximum length of Boom 8m, boom rest stand, aluminium arm material, time forUp/down 8s, Input control signal:Dry contact, Ingress Protection Degree:IP54, Input Interface for:Photocell, Airswitch, Loopdetector(Optional), Output interface:Access control panel, Standalone access control,Control button, Remote control Upto 25 meters, Mode: Automatic/Manual In corported control panel with3 push bottons (STOP/UP/Down) to conrol the motor, Bumping bounce back:Yes, Auto closing time:1-80s, including installation charges complete

2

-

-

... More
Road works

-

-

-

... More
3.15 : Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means br

7635.01

-

-

... More
3.32 : Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres.

2500

-

-

... More
55.2 : Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a)

2

-

-

... More
55.4 : Supplying and stacking 36mm size hard broken stone in standard heaps for measurement.

2

-

-

... More
55.8.a : Filling up pot holes (cut and formed to regular shapes and all loose and defective materials removed) after supplying a prime coat of hot bitumen using 36mm departmental broken stone and compacting with power roller to get a compact surface.

2

-

-

... More
55.9.a : Filling up pot holes (cut and formed to regular shapes and all loose and defective materials removed) after supplying a prime coat of hot bitumen using 12mm departmental broken stone and compacting with power roller to get a compact surface.

2

-

-

... More
od341593/2021_2022 : Construction of sub-grade and earthen shoulders with available approved material with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2

875

-

-

... More
4.1.A.1 : Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 br Grading-I - Plant Mix Method

700

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

393.75

-

-

... More
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

2625

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

7635.01

-

-

... More
5.7.1 : Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.09 mm (Type-A) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade.

7635.01

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

460.05

-

-

... More
8.35 : Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-

347

-

-

... More
8.4.2 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.br 60 cm equilateral triangle

5

-

-

... More
8.4.3 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.br 60 cm circular

10

-

-

... More
8.4.4 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.br 80 mm x 60 mm rectangular

5

-

-

... More
8.4.12 : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.br 50cmx 60 cm rectangular (Single chevron etc.)

5

-

-

... More
Electrical

-

-

-

... More
1.3.1 : Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

5

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

400

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

200

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

200

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

15

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

5

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

5

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

5

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

100

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

100

-

-

... More
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm

200

-

-

... More
od323416/2021_2022 : Supply of 8m height Hot Dip Galvanized Octagonal Pole with top dia 70 mm, bottom dia 130 mm, sheet thickness 3mm, base plate of 200X200X12 mm size with 1000 mm long double arm bracket suitable for mounting two No's LED street light fixtures. The pole shall be installed on a 1:1.5:3(M20) concrete plinth as per the detailed drawing. Providing separate adequate size PVC pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 16mm dia 450 mm length, projected bolt size length 80 mm pitch circle dia 200mm to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template. The threaded portion of foundation bolt protruded out side the plinth shall be galvanized. Terminal box with 6A SP MCB, neutral link, earth terminating facility and 16A, 4pole terminal block etc shall be fixed inside the octagonal pole as required as per the tender specifications and approved list of makes.

7

-

-

... More
od323418/2021_2022 : Installation of item no. 12

7

-

-

... More
od323420/2021_2022 : Supply of 8m height Hot Dip Galvanized Octagonal Pole with top dia 70 mm, bottom dia 130 mm, sheet thickness 3mm, base plate of 200X200X12 mm size with 1000 mm long single arm bracket suitable for mounting one No's LED street light fixtures. The pole shall be installed on a 1:1.5:3(M20) concrete plinth as per the detailed drawing. Providing separate adequate size PVC pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 16mm dia 450 mm length, projected bolt size length 80 mm pitch circle dia 200mm to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template. The threaded portion of foundation bolt protruded out side the plinth shall be galvanized. Terminal box with 6A SP MCB, neutral link, earth terminating facility and 16A, 4pole terminal block etc. shall be fixed inside the octagonal pole as required as per the tender specifications and approved list of makes.

3

-

-

... More
od323422/2021_2022 : Installation of item no.14

3

-

-

... More
od323423/2021_2022 : Supply of high-quality integrated LED Street Light Luminaire having power consumption not more than 75 W and light output not less than 9000 Lumens with a nominal efficiency> 120lumen/watt. The housing should be of non-corrosive high-pressure die-cast aluminum LM6 Grade to with stand extreme environments and should have corrosion resistant powder coating to pass NSS of 500 Hrs. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related color temperature (CCT) of 5700K. The Ingress protection should be minimum IP 66 with an IK rating of 08. The LED used in the luminaire shall be High power type only of make Lumileds, Osram, Nichia, and CREE & no other make with each led wattage not less than 1w and not more than 3w. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs and operating voltage range 120-277 V. The Luminaire should have a 10 KV SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2 . The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF>0.95 and THD<10%. Luminaire and driver shall be separately BIS approved.

17

-

-

... More
od323424/2021_2022 : Installation, Testing & Commissioning of item no. 5

17

-

-

... More
od78837/2022_2023 : Supply of 12.5 high mast pole with its accessories. Mast shaft be in two sections suitable for wind velocity as per IS 875 part 3 with raising lowering system, luminaires carriage suitable to install 6 nos LED Flood Light in symmetrical/asymmetrical arrangement, double arm winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, feeder pillar, and cables from feeder pillar to the high mast, lighting final, etc. complete. Including supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates, template, supply and installation of twin dome aviation obstruction light, etc. "<br><br>

1

-

-

... More
od79560/2022_2023 : Installation, Testing & Commissioning of item no:18

1

-

-

... More
od323427/2021_2022 : Supply of LED Flood light luminaire not greater than 170W, BIS certified with a flat toughened glass protector (IK08), body of high pressure die cast aluminium, separate optical & control gear compartments (IP66). Overall luminous efficiency greater than 100lm/W at correlated colour temperature (CCT) of 5700K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driverhaving internal surge protection of 4 kV and an additional surge protection device(SPD) of 10 kV .<br>

6

-

-

... More
od323428/2021_2022 : Installation testing and commissioning of item no.19

6

-

-

... More
od323429/2021_2022 : Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submission of Completion report, arranging inspection, getting sanction for energization of the installation from Electrical Inspectorate for commissioning of the street lights in the premises. Statutory payments will be reimbursed on production of the original receipts/ attested copies of original.

1

-

-

... More
od323433/2021_2022 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required<br>

1000

-

-

... More
od323434/2021_2022 : Supplying and installing following 150 mm width X 50 mm depth X 1.6 mm thickness<br> size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.<br>

60

-

-

... More
od323436/2021_2022 : Dismantling of existing electric post including cross arms , insulators, ACSR and all allied accessories and shifting the same to a location as instructed by Engineer-in Charge

10

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

16

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

5

-

-

... More
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural

3

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

5

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

5

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

670

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

150

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

105

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

38

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

160

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

80

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

170

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

65

-

-

... More
od323441/2021_2022 : SITC of following Light/Fan fixtures complete with accessories. Rate shall include necessary mounting bracket, suspension chains etc.<br>LED Panel light 12 W LED 4000 K, surface mounted, round fitting ultra slim with control driver etc.<br>

3

-

-

... More
od323442/2021_2022 : SITC of following Light/Fan fixtures complete with accessories. Rate shall include necessary mounting bracket, suspension chains etc.<br>Surface and wall mounted LED batten extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser & integrated electronic driver with lamp 20 W LED 5700 K IP40<br>

5

-

-

... More
od323445/2021_2022 : SITC of following Light/Fan fixtures complete with accessories. Rate shall include necessary mounting bracket, suspension chains etc.<br>Gate light 20W LED lamp designed with symmetrically light distributed, spun aluminium luminiare with high power LED light source suitable for pole dia 75mm or nearest<br>

5

-

-

... More
od348301/2021_2022 : Supply of Bollard Lamp fitting IP65/66, 3000K/4000K with energy saving aluminium housing landscape luminaire for diffused lighting with 7W-10W ranging LED Light source of height <800mm, LED Warm light

10

-

-

... More
od348802/2021_2022 : Supply of Gardening Spotlight with COB LED, IP 65/67 ranging from 6W to 9W, having CCT not less than 3000 K, CRI 70 suitable for landscaping.

10

-

-

... More
od323447/2021_2022 : Supply, installation, testing and commissioning of 450mm wall fan with necessary bolt and nuts, etc. as required including giving connections with required length of 16/0.20mm pvc insulated and PVC sheathed 3 core round copper conductor flex wire confirming to relevant IS

2

-

-

... More
od323449/2021_2022 : <br>Supply of XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE.<br>4C x 6Sq. mm- <br><br>

300

-

-

... More
od323450/2021_2022 : <br>Supply of XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE.<br>4C x 10Sq. mm-<br><br>

400

-

-

... More
od323451/2021_2022 : <br>Supply of XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE.<br>3.5C x 70Sq. mm- <br><br>

340

-

-

... More
od348582/2021_2022 : Supply of XLPE insulated armoured cables with aluminium conductors for working voltages upto and including 1100V conforming to IS 1554 part 1 1988 for PVC and IS 7098 PRT 1 for XLPE 2C x 4 sq mm Al cable

410

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

10

-

-

... More
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.

5

-

-

... More
1.35 : Erection of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.

10

-

-

... More
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

1

-

-

... More
1.51 : Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

1

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

4

-

-

... More
od323452/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1Kv grade as required.<br>4C x 6Sq. mm- <br>

20

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

46

-

-

... More
14.14.3 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.250 mm dia

28

-

-

... More
od323457/2021_2022 : Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>4C X 10 sq. mm

5

-

-

... More
od323458/2021_2022 : Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>4C X 6 sq. mm

15

-

-

... More
od323459/2021_2022 : Supply Installation Testing and Commission of Cable junction Polycarbonate boxes with IP66/65 weather proof for outdoor installations including all accessories.

12

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

30

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

5

-

-

... More
od323463/2021_2022 : Supplying of Ceiling Fan 1200mm Sweep complete with 300mm down rod, canopies, shackles and blades and without regulator working on 230/240V Single phase AC<br>

1

-

-

... More
od323464/2021_2022 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing<br> watering pipe etc. (but without charcoal/ coke and salt ) as required.

10

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

1

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

-

-

... More
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

1210

-

-

... More
od324553/2021_2022 : Supplying of Exhaust Fan 450mm working on 230/240V Single phase AC<br>

1

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

5

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
od348470/2021_2022 : supply and installation of TOD type energy meter (3 Ph LTCT-/240V, -/5A <br>rated) as per IS 14697, Class of Accuracy : 0.5s<br>RS 485 Modbus communication.

1

-

-

... More
od349190/2021_2022 : Supply, Installation, Testing, and Commissioning of IP54 rated, dust and vermin proof, wall mounting type indoor panel fabricated using 16 SWG CRCA sheet steel, degreased, phospated and powder coated with suitable provision for top/bottom cable entry. The panel incomer and outgoings as per the electrical scheme drawing.<br><br>Incomer:<br><br>32 A 4P 100mA RCBO 1 nos, with Phase Indication Lamps (Red, Yellow & Blue), 3Nos. 6A, 1P, 10KA, MCB with 1No Neutral Link for Lamp circuit control - 1 Set<br><br>Outgoings :<br><br>1. 3Nos. 6A, SP, 10KA, MCBs, 1No. 9A, 3P, Power Contactor, 1No. Timer, 1No. Auto-Manual Selector Switch, 1Set ON/OFF Indication Lamps & 1 Set 6A 1P MCB with Neutral Link16A TP MCB – 1nos<br><br>2. 1No. 16A, 3P, 10KA, MCBs, 1No. 8A, 3P, Power Contactor, 1No. Timer, 1No. Auto-Manual Selector Switch, 1Set ON/OFF Indication Lamps & 1 Set 6A 1P MCB with Neutral Link<br><br>3. 2Nos. 6A, SP, 10KA, MCBs, 1No. 9A, 3P, Power Contactor, 1No. Timer, 1No. Auto-Manual Selector Switch, 1Set ON/OFF Indication Lamps & 1 Set 6A 1P MCB with Neutral Link.<br><br>(The rate shall include Auto ON/OFF timers, contactors, and other accessories, LED indication lamps for incoming supply status, Copper busbar with SMC supports inter panel wiring)

1

-

-

... More
Plumbing

-

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
17.7.3 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps

1

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

1

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

250

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

250

-

-

... More
18.8.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

250

-

-

... More
od114168/2022_2023 : Providing and fixing Ball hose tap including cutting and making good the walls and floors as per the requirement.

8

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

5

-

-

... More
18.48A : Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.

500

-

-

... More
od323411/2021_2022 : Providing, Fixing, testing and commissioning at site in position uPVC pipe (SWR-Type A) (IS:13592) or ( IS : 4985 ) With Rubber Ring or Solvent Welded fittings with bosses where required e.g. tees, bends, clamps, coupling, etc. complete. (For Rain water pipes )<br>63 mm O.D ( 4Kg/cm2) Vent pipe in shaft<br>

20

-

-

... More
od323413/2021_2022 : Providing,Fixing, testing and commissioning at site 150x150 mm square C.P. cast brass or stainless steel anti cockroach grating cover SS (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. <br>

2

-

-

... More
od323415/2021_2022 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This included jointing of pipes& fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including chases and making good the walls etc. (Internal Cold Water Supply)<br>32 mm dia.nominal outer dia pipes.<br>

50

-

-

... More
od323417/2021_2022 : Providing,Fixing,testing and commissioning at site GI Slotted Rail Brackets,hangers,supports with necessary drilling holes to suit the inzertion of pipe clamps, deburring etc.,as per detailed drawing for supporting soil, waste & rain water pipes & water supply pipes in shafts with suitable GI clamps,bolts,anchor bolts nuts & washers fixed on shaft walls/outer walls etc.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer.<br>Hot dip galvanized (Fully exposed to weather and wet areas)<br>

40

-

-

... More
od323419/2021_2022 : Providing,Fixing,testing and commissioning at site GI Slotted Rail Brackets,hangers,supports with necessary drilling holes to suit the inzertion of pipe clamps, deburring etc.,as per detailed drawing for supporting soil, waste & rain water pipes & water supply pipes in shafts with suitable GI clamps,bolts,anchor bolts nuts & washers fixed on shaft walls/outer walls etc.The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 1.6mm thick confirmed to IS 1239 etc.,complete as directed by the employer<br>Electro Galvanized (In shaft and dry interior areas)<br>

30

-

-

... More
od323421/2021_2022 : Providing and Laying of pipes and conveying to position; cleaning, laying and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2) including jointing the pipe as per specification, testing the pipe line after installation all per provisions of IS: 1742-1983 (Code of practice for building drainage) complete <br>110mm OD <br>

60

-

-

... More
od114435/2022_2023 : Providing, Fixing, testing and commissioning at site in position u PVC pipe of 6Kg/sq.cm (IS:4985) & SWR Type B IS 13592 including PVC fittings with bosses where required e.g. tees, bends, clamps, coupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts, washers, wherever required etc. complete. (For Internal waste line)<br>75 mm <br>

60

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

600

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

100

-

-

... More
od324555/2021_2022 : "Providing, Fixing, testing and commissioning at site in position Deep Seal UPvc fabricated Multi floor trap (7”), with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. complete in all respects.<br>50/75 mm dia outlet (In Ceiling) "<br>

1

-

-

... More
od348849/2021_2022 : Supply Installation Testing and Commissioning of 32mm Water Meter dial type brass body screwed end

1

-

-

... More
Landscape works

-

-

-

... More
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil

959

-

-

... More
30.2.2 : Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

170

-

-

... More
30.2.25 : Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

65

-

-

... More
30.2.9 : Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

192

-

-

... More
30.2.56 : Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.

959

-

-

... More
od347843/2021_2022 : Spreading of cattle manure and good earth in required thickness as per direction of officer-in-charge (cost of manure and good earth to be paid separately).

192

-

-

... More
30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

80

-

-

... More
od347888/2021_2022 :  Supplying and Planting grass over the earth closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge.<br>Axonopus compressus<br>

705

-

-

... More
od348453/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a minimum height of 180 cm, height of the main stem 30 cm and a minimum girth of 12.5 to 15 cm at the time of planting)<br>Trees<br>Fox tail palm.<br><br>

200

-

-

... More
od348454/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 30 cm at the time of planting)<br>Trees<br>Tabernaemontana Divaricata miniature plant (crepe jasmine).<br><br>

4000

-

-

... More
WORKS IN NON_SEZ AREA

-

-

-

... More
Road works

-

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

16200

-

-

... More
5.7.1 : Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.09 mm (Type-A) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade.

16200

-

-

... More
3.15 : Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means br

16200

-

-

... More
55.4 : Supplying and stacking 36mm size hard broken stone in standard heaps for measurement.

3

-

-

... More
55.2 : Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a)

3

-

-

... More
55.8.a : Filling up pot holes (cut and formed to regular shapes and all loose and defective materials removed) after supplying a prime coat of hot bitumen using 36mm departmental broken stone and compacting with power roller to get a compact surface.

3

-

-

... More
55.9.a : Filling up pot holes (cut and formed to regular shapes and all loose and defective materials removed) after supplying a prime coat of hot bitumen using 12mm departmental broken stone and compacting with power roller to get a compact surface.

3

-

-

... More
8.13 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

1170

-

-

... More
8.35 : Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-

688

-

-

... More
Repairs and other miscellaneous Works

-

-

-

... More
od346258/2021_2022 : Removing waste and cleaning the existing drain and disposing off the waste in suitable locations as instructed by the engineer in charge upto 50 m lead complete

3200

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

35

-

-

... More
15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

110

-

-

... More
14.1.2 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand)

250

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

70

-

-

... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)

380

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

110.54

-

-

... More
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)

5

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

32

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

6

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

29

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

3

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

170

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

10

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

150

-

-

... More
od130515/2022_2023 : Providing and fixing square-mouth brick masonry chamber of size 300x300mm, depth of the chamber upto 1m and thickness of the wall 100 mm for hume pipe crossings with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. Work includes cement concrete foundation in the ratio 1:2:4 and inside plastering in CM 1:3 with thickness 12 mm

6

-

-

... More
od347333/2021_2022 : Providing and fixing 100 mm sand cast Iron grating for drain pipes or gully traps.

500

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

3

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

3

-

-

... More
Electrical

-

-

-

... More
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm

70

-

-

... More
od346271/2021_2022 : Supply of 12.5m high mast pole with its accessories. Mast shaft shall be in two sections suitable for wind velocity as per IS 875 part 3 with raising lowering system, luminaires carriage suitable to install 6 nos LED Flood Light in symmetrical/asymmetrical arrangement, double arm winch, 6 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, feeder pillar and cables from feeder pillar to high mast, lighting finial etc. complete. Including supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates, template, supply and installation of twin dome aviation obstruction light etc. complete as per the tender specifications and approved list of makes.

1

-

-

... More
od346272/2021_2022 : Installation, Testing & Commissioning of item no.2

1

-

-

... More
od346273/2021_2022 : Supply of LED Flood light luminaire not greater than 170W, BIS certified with a flat toughened glass protector (IK08), body of high pressure die cast aluminium, separate optical & control gear compartments (IP66). Overall luminous efficiency greater than 100lm/W at correlated colour temperature (CCT) of 5700K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driverhaving internal surge protection of 4 kV and an additional surge protection device(SPD) of 10 kV .

6

-

-

... More
od346274/2021_2022 : Installation testing and commissioning of item no.4

6

-

-

... More
od346275/2021_2022 : Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submission of Completion report, arranging inspection, getting sanction for energization of the installation from Electrical Inspectorate for commissioning of the street lights in the premises. Statutory payments will be reimbursed on production of the original receipts/ attested copies of original.

1

-

-

... More
od346278/2021_2022 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required<br>

200

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

100

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

40

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

300

-

-

... More
od346291/2021_2022 : <br>Supply of XLPE insulated armoured cables with aluminium conductors for working voltages up to and including 1100V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE.<br>4C x 10Sq. mm- <br><br>

440

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
14.14.2 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia

40

-

-

... More
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)

35

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

1

-

-

... More
Landscaping Works

-

-

-

... More
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil

940

-

-

... More
30.2.2 : Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

170

-

-

... More
30.2.25 : Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment).

70

-

-

... More
30.2.9 : Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

188

-

-

... More
30.2.56 : Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.

940

-

-

... More
od347335/2021_2022 : Spreading of cattle manure and good earth in required thickness as per direction of officer-in-charge (cost of manure and good earth to be paid separately).

188

-

-

... More
30.2.33 : Providing and fixing Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and even, watering with sprinkler

670

-

-

... More
od347336/2021_2022 :  Supplying and Planting grass over the earth closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge.<br>Axonopus compressus<br>

240

-

-

... More
od348408/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a minimum height of 180 cm, height of the main stem 30 cm and a minimum girth of 12.5 to 15 cm at the time of planting)<br>Trees<br>Fox tail palm.<br><br>

100

-

-

... More
od348409/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 30 cm at the time of planting)<br>Trees<br>Calathea lutea.<br><br>

180

-

-

... More
od348410/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 40 cm at the time of planting)<br>Trees<br>Miniature bogainvilla.<br><br>

20

-

-

... More
od348430/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 30 cm at the time of planting)<br>Trees<br>Ixora hybrid miniature.<br><br>

50

-

-

... More
od348431/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 30 cm at the time of planting)<br>Trees<br>.<br>Aplinia.<br>

30

-

-

... More
od348432/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 60 cm at the time of planting)<br>Trees<br>.<br>Melastoma.<br>

30

-

-

... More
od348433/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 20 - 30 cm at the time of planting)<br>Trees<br>.<br>plumbago.<br>

100

-

-

... More
od348385/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 90 cm at the time of planting)<br>Trees<br>.<br>Budha bamboo.<br>

30

-

-

... More
od348386/2021_2022 : Supplying and planting healthy plants of the following species of appropriate growth including necessary maintenance of the plants (as and when required) at site as directed by Engineer-in-Charge. (Trees to have a height of 30 cm at the time of planting)<br>Trees<br>.<br>Spider lilly.<br>

50

-

-

... More
30.2.50 : Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.