Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Civil And Construction
Eprocure
Opening Date16 Jul 2019
Closing Date7 Aug 2019
Tender Amount₹ 3,27,32,804 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Interior Fit Out Works At Infopark Kochi Phase 1 Campus Located At Kakkanad, Kochi, Kerala

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
 Demolishing brick work manually / by mechanical means including stacking of serviceable material within 50 metres lead and disposal of unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

29.5

-

1347.5

... More
 Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete Of area 3 sq. metres and belowand stacking within 50 metres lead and all lifts

71

-

220.82

... More
 Dismantling tile work of tiles 10 mm to 25 mm thickness in floors, walls and roofs laid in cement mortar including stacking material of serviceable material within 50 meters lead and disposal of unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

1565

-

47.09

... More
 Dismantling tile work of tiles above 25 mm and up to 40 mm thickness in floors and roofs laid in cement mortar including stacking of serviceable material within 50 metres lead and disposal of unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

204.1

-

74.3

... More
 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

31

-

33.36

... More
 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including stacking of serviceable material with in 50 metres lead and disposal of unserviceable surplus material or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

1530

-

36.04

... More
 Dismantling water closet carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

15

-

347.31

... More
 Dismantling wash basin, sink etc. carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

17

-

165.44

... More
 Dismantling urinal carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

14

-

131.97

... More
 Dismantling fixtures such as Pillar cock, sink cock, health faucet, valves etc carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

78

-

15.83

... More
 Dismantling consealed pipe lines (including supply & waste lines) carefully, clearing away and stacking the material in the stockyard within Infopark campus as per directions of Engineer-in-charge

250

-

159.69

... More
 Dismantling mirror carefully and stacking in the stackyard within 50 meters lead as per directions of Engineer-in-charge.

15

-

404.39

... More
 Dismantling toilet paper holder carefully and stacking the material in the stackyard within 50 meters lead as per direction of Engineer-in-charge

15

-

39.78

... More
 Dismantling wooden boardings in lining of walls and partitions, underdeck insulation excluding supporting members but including stacking of serviceable material with in 50 metres lead and disposal of unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved :

1068.7

-

38.02

... More
Laying and Jointing PVC Pipe. Heading

-

-

-

... More
 Screeding - cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, including cement slurry, etc. complete as per directions of Engineer-in-charge

36.452

-

12681.45

... More
Brick Jelly Concrete - Toilet Subfloor Filling : Providing & Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope including rounding of junctions of walls and slabs.

23.625

-

8823.48

... More
 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

171.35

-

417.29

... More
 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

5

-

10338.99

... More
 Centering and shuttering including strutting, etc. and removal of form for Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like

20

-

271.32

... More
 Steel reinforcement using Thermo - Mechanically Treated bars of grade Fe-500D or more for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level

500

-

79.18

... More
Masonry works

-

-

-

... More
 Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above floor 2 level up to floorV level in cement mortar 1:4 (1 cement :4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

35.202

-

9538.54

... More
 Half brick masonry in cement mortar 1:4 (1 cement : 4 coarse sand ) with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.

19.968

-

957.13

... More
 Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

19.968

-

79.53

... More
Flooring works

-

-

-

... More
 Providing and laying vitrified floor tiles of size 800x 800 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.

1427.509

-

1979.37

... More
 Providing and laying Vitrified tiles of size 800 x 800 mm (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

10

-

2004.34

... More
 Providing and laying vitrified floor tiles of size 600 x 600 mm. (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.

88.17

-

1565.93

... More
 Providing and laying Vitrified tiles of size 600x600 mm (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

10

-

1588.03

... More
 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Basic price of tile - Rs.65 incl per sq.ft.

353.8

-

1398.04

... More
 Making chases by cutting floor tiles up to 25 cm in width and 12.5 cm in depth including making good after race way installation and finishing to match surrounding area

125

-

2381.68

... More
 Providing and fixing 100mm height Aluminium Modular skirting of approved make at Masonry walls & Partitions, and of approved shape & profile . The systems shall be of complete aluminium type including capping strips. It shall be made of extruded aluminium of 1.3mm gauge avg. & anodized to 20 microns avg. Rate to include supply & installation of matching colour corner guards. Rate to include all hardware, etc complete.

670.48

-

317.98

... More
 Providing and fixing 18 mm thick Granite of any colour and shade (area of slab upto 0.50 sqm) gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Basic rate of granite - Rs.227/- per sq.ft.)

16.752

-

4689.04

... More
 Providing and fixing 18 mm thick Granite of any colour and shade (area of slab over 0.50 sqm)gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(Basic rate of granite - Rs.234/- per sq.ft.)

5.526

-

4355.2

... More
 Providing and fixing removable raised/false access flooring 300 mm Finished Floor Height (FFH). with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.

13.306

-

5629.87

... More
 Granite Shelf : Providing and fixing Granite stone slab with table rubbed, edges rounded and polished, of 50 cm deep and 1.8 cm thick, fixed as Handbag Shelf in the Ladies Restroom, by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. (Basic Rate of Granite - Rs.220/- per sft.).

0.75

-

3961.66

... More
Finishing works

-

-

-

... More
 Plastering of walls with 1:4 cement mortar and 15 mm thickness, with rough finish suitable for subsequent wall tiling dado works. Rate shall include for scaffolding, form work as necessary and curing, providing Plaster mesh made out of galvanised iron of nominal thickness 0.35 mm with a Zinc coating of 12 gms per Sft to a width of 4" to 6" at the junctions of Masonry and concrete works including tying in position by using suitable nails / clamps / screws etc. complete all as directed.

485.34

-

384.56

... More
 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite / perite respectively conforming to IS : 2547 ( Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.

816.6

-

304.05

... More
 Applying priming coats with water thinnable cement primer of approved brand and manufacture on walls having low VOC ( Volatile Organic Compound) content less than 50 grams/litre.

862.84

-

51.69

... More
 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

862.84

-

122.26

... More
 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

1826

-

166.05

... More
 Wall painting two coats with premium acrylic emulsion paint of interior grade, having VOC less than 50 grams/litre.including applying additional coats wherever required to achieve even shade and colour.

1826

-

99.32

... More
 Painting with synthetic enamel paint (steel work) of approved brand and manufacture of required colour to an give even shade:

200

-

71.76

... More
False ceiling works

-

-

-

... More
 Providing and fixing false ceiling with 12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:

662.02

-

1127.79

... More
 Providing and fixing false ceiling with 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS; 2095-Part I at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:

21

-

1289.86

... More
 Providing and fixing false ceiling with 12.5 mm thick tapered edge gypsum moisture resistant boardat all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:

42.36

-

1341.06

... More
 Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS:8183, density 48 Kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to roof slab with metallic cleats (50x50x3mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh as per directions of Engineer-in-charge

1060

-

550.05

... More
 Providing and fixing tiled false ceiling with GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 600x600 mm and 0.5mm thick ; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.of size 600 x 600 mm in true horizontal level, suspended on Silhoutte inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and spaced at 1200mm center to center and cross "T" 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.

462.08

-

1965.61

... More
 Providing and fixing tiled false ceiling with GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 1200x600 mm and 0.5mm thick ; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. in true horizontal level, suspended on Silhoutte inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and spaced at 1200mm center to center and cross "T" 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.

235.28

-

2621.74

... More
 Providing and fixing tiled false ceiling with GI Metal Ceiling Lay in perforated Tegular black color tiles of size 600x600 mm and 0.5mm thick ; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. in true horizontal level, suspended on Silhoutte inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and spaced at 1200mm center to center and cross "T" 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.

20.88

-

2557.1

... More
 Providing and fixing tiled false ceiling with GI Metal Ceiling Lay in plain global white color tiles of size 600x600 mm and 0.5mm thick ; made of GI sheet having galvanizing of 100 gms/ sqm (both sides inclusive), electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending. in true horizontal level, suspended on Silhoutte inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and spaced at 1200mm center to center and cross "T" 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.

45

-

1611.93

... More
 Providing and fixing of 150mm width Armstrong Techzone (Module TZ4) or approved equivalent Suspended ceiling system as per the required centre-to-centre spacing as per the ceiling drawings. The Techzone orientation shall be such that the main runners run parallel or perpendicular to the technical zone as indicated in the ceiling drawings. The 150mm wide technical zone formed is where the technical elements like lighting fixtures, HVAC diffusers, etc would be installed. Where there are no technical elements the technical zone would be covered by using Metal Technical Panels of size 1200mm x150mm in conjunction with a special 150mm long cross tee, interlocked at every 1200mm in the technical zone.

20

-

2475.47

... More
 Ceiling trap door/access panel in gyp ceiling of 1200 mm x 600 mm size made from aluminum Powder coated frame and MR gypsum board with click lock, guard hook, safety rope, brush sealing strip etc. The rate shall include for finished with two coats of premium acrylic emulsion paint over a coat of primer and putty as directed by Engineer-in-charge

10

-

5807.5

... More
Joineries

-

-

-

... More
 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing SS top & bottom patch fitting, floor spring suitable for the door size, corner lock fitting with floor lock plate, SS H handle 600 mm size and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

24.841

-

21727.86

... More
Supplying and installation of steel Fire door of size 1200 x 2400 mm size with Fire Rating of 120 minutes rating as per manufacturers specification and tested in accordance with IS 3614 Part-2 BS 476 Part-22 (a) Fire resistant door frame made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) of section 143x57 mm having built in rebate duly filled with vermiculate based concrete mix, suitable for mounting door shutters, kerf frame fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, reinforcement pads for fixing of door closer at appropriate location, factory finished pre-punched cut-outs to receive specific hardware and ironmongery, requisite mortar guard, hinge plates predrilled to receive hinges for screw mounted fixing, minimum of three anchors per jamb suitable for adjoining wall construction, etc as per site conditions, Grouting the frame with cement slurry including providing necessary Hilti make Intumescent Joint Filler - code no CP 606 or Wacker - R - Glazing & Metal (Elastomeric / Intumescent) in the gaps between Wall & Frame to the required thickness and to be applied by using suitable Dispenser tool etc complete as per manufacture's specification. (b) Fire door shutters to be manufactured from 18 SWG G.I. sheets(zinc coating not less than 120 gm/sqm) to be press formed to 46 mm thick double skin hollow door with lock seam joints at stile edges with a bending radius of 1.4 mm, with internal reinforcement at top, bottom and stile edges made out of 16 SWG G.I. sheet duly filled FR insulation material (96 kg/cum density), the door face should not have visible screws or fasteners on either face and the doors to have pre-drilled hinge plates with hinge guard covers, fixing with necessary stainless steel ball bearing hinges in the factory prepared pre-punched cut-outs and reinforcements, locks with concealed lock box with lock fixing brackets with pre-tapped holes, door closer reinforcement pads at appropriate location (c) Vision panel of size 200x300 mm using 6 mm clear fire resistant glass fixed with GI beading of appropriate size, fire resistant sealant, beading, screws from inside etc. The rate shall also include provision for finishing with zinc phosphate storing primer & polyurethane paint and required ironmongery such as : a. door closers , b. stainless steel satin finish double ball bearing butt hinges with SS screws of required size c. Mortice Sash lock stainless steel satin finish with 5 pin tubular brass cylinder 70 mm thick with external key provision with knob, lever lock and handles, strike plate Type of lock shall be provided suitably as per site requirement. d. Stainless steel H handle 600 mm height of reputed brand and manufacture to be approved by the Engineer-in-charge Rate shall be inclusive of making cut-outs, provisions, etc for receiving Access Control provision

20.16

-

14991.13

... More
Supplying and installation of steel Fire door of size 1200 x 2400 mm size with Fire Rating of 120 minutes rating as per manufacturers specification and tested in accordance with IS 3614 Part-2 BS 476 Part-22 . (a) Fire resistant door frame made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) of section 143x57 mm having built in rebate duly filled with vermiculate based concrete mix, suitable for mounting door shutters, kerf frame fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, reinforcement pads for fixing of door closer at appropriate location, factory finished pre-punched cut-outs to receive specific hardware and ironmongery, requisite mortar guard, hinge plates predrilled to receive hinges for screw mounted fixing, minimum of three anchors per jamb suitable for adjoining wall construction, etc as per site conditions, Grouting the frame with cement slurry including providing necessary Hilti make Intumescent Joint Filler - code no CP 606 or Wacker - R - Glazing & Metal (Elastomeric / Intumescent) in the gaps between Wall & Frame to the required thickness and to be applied by using suitable Dispenser tool etc complete as per manufacture's specification. (b) Fire door shutters to be manufactured from 18 SWG G.I. sheets(zinc coating not less than 120 gm/sqm) to be press formed to 46 mm thick double skin hollow door with lock seam joints at stile edges with a bending radius of 1.4 mm, with internal reinforcement at top, bottom and stile edges made out of 16 SWG G.I. sheet duly filled FR insulation material (96 kg/cum density), the door face should not have visible screws or fasteners on either face and the doors to have pre-drilled hinge plates with hinge guard covers, fixing with necessary stainless steel ball bearing hinges in the factory prepared pre-punched cut-outs and reinforcements, locks with concealed lock box with lock fixing brackets with pre-tapped holes, door closer reinforcement pads at appropriate location (c) Vision panel of size 200x300 mm using 6 mm clear fire resistant glass fixed with GI beading of appropriate size, fire resistant sealant, beading, screws from inside etc. The rate shall also include provision for finishing with zinc phosphate storing primer & polyurethane paint and required ironmongery such as : a. door closers, b. stainless steel satin finish double ball bearing butt hinges with SS screws of required size , c. Mortice Sash lock stainless steel satin finish with 5 pin tubular brass cylinder 70 mm thick with external key provision with knob, lever lock and handles, strike plate Type of lock shall be provided suitably as per site requirement., d. Panic bar/ latch (double point) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the Engineer-in-charge Rate shall be inclusive of making cut-outs, provisions, etc for receiving Access Control provision.

2.88

-

16109.98

... More
 Supplying and installation of steel Fire door double leaf of size 1800 x 2100 mm with Fire Rating of 120 minutes rating as per manufacturers specification and tested in accordance with IS 3614 Part-2 BS 476 Part-22 . (a) Fire resistant door frame made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) of section 143x57 mm having built in rebate duly filled with vermiculate based concrete mix, suitable for mounting door shutters, kerf frame fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, reinforcement pads for fixing of door closer at appropriate location, factory finished pre-punched cut-outs to receive specific hardware and ironmongery, requisite mortar guard, hinge plates predrilled to receive hinges for screw mounted fixing, minimum of three anchors per jamb suitable for adjoining wall construction, etc as per site conditions, Grouting the frame with cement slurry including providing necessary Hilti make Intumescent Joint Filler - code no CP 606 or Wacker - R - Glazing & Metal (Elastomeric / Intumescent) in the gaps between Wall & Frame to the required thickness and to be applied by using suitable Dispenser tool etc complete as per manufacture's specification. (b) Fire door shutters to be manufactured from 18 SWG G.I. sheets(zinc coating not less than 120 gm/sqm) to be press formed to 46 mm thick double skin hollow door with lock seam joints at stile edges with a bending radius of 1.4 mm, with internal reinforcement at top, bottom and stile edges made out of 16 SWG G.I. sheet duly filled FR insulation material (96 kg/cum density), the door face should not have visible screws or fasteners on either face and the doors to have pre-drilled hinge plates with hinge guard covers, fixing with necessary stainless steel ball bearing hinges in the factory prepared pre-punched cut-outs and reinforcements, locks with concealed lock box with lock fixing brackets with pre-tapped holes, door closer reinforcement pads at appropriate location (c) Vision panel of size 200x300 mm using 6 mm clear fire resistant glass fixed with GI beading of appropriate size, fire resistant sealant, beading, screws from inside etc. The rate shall also include provision for finishing with zinc phosphate storing primer & polyurethane paint and required ironmongery such as : a. door closers , b. stainless steel satin finish double ball bearing butt hinges with SS screws of required size , c. Stainless steel H handle 600 mm height. , Rate shall be inclusive of making cut-outs, provisions, etc for receiving Access Control provision.

15.121

-

16158.74

... More
Supplying and installation of steel Fire door of size 1000 x 2100 mm size with Fire Rating of 120 minutes rating as per manufacturers specification and tested in accordance with IS 3614 Part-2 BS 476 Part-22 . (a) Fire resistant door frame made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) of section 143x57 mm having built in rebate duly filled with vermiculate based concrete mix, suitable for mounting door shutters, kerf frame fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, reinforcement pads for fixing of door closer at appropriate location, factory finished pre-punched cut-outs to receive specific hardware and ironmongery, requisite mortar guard, hinge plates predrilled to receive hinges for screw mounted fixing, minimum of three anchors per jamb suitable for adjoining wall construction, etc as per site conditions, Grouting the frame with cement slurry including providing necessary Hilti make Intumescent Joint Filler - code no CP 606 or Wacker - R - Glazing & Metal (Elastomeric / Intumescent) in the gaps between Wall & Frame to the required thickness and to be applied by using suitable Dispenser tool etc complete as per manufacture's specification. (b) Fire door shutters to be manufactured from 18 SWG G.I. sheets(zinc coating not less than 120 gm/sqm) to be press formed to 46 mm thick double skin hollow door with lock seam joints at stile edges with a bending radius of 1.4 mm, with internal reinforcement at top, bottom and stile edges made out of 16 SWG G.I. sheet duly filled FR insulation material (96 kg/cum density), the door face should not have visible screws or fasteners on either face and the doors to have pre-drilled hinge plates with hinge guard covers, fixing with necessary stainless steel ball bearing hinges in the factory prepared pre-punched cut-outs and reinforcements, locks with concealed lock box with lock fixing brackets with pre-tapped holes, door closer reinforcement pads at appropriate location (c) Vision panel of size 200x300 mm using 6 mm clear fire resistant glass fixed with GI beading of appropriate size, fire resistant sealant, beading, screws from inside etc. The rate shall also include provision for finishing with zinc phosphate storing primer & polyurethane paint and required ironmongery such as : a. door closers , b. stainless steel satin finish double ball bearing butt hinges with SS screws of required size , c. Mortice Sash lock stainless steel satin finish with 5 pin tubular brass cylinder 70 mm thick with external key provision with knob, lever lock and handles, strike plate Type of lock shall be provided suitably as per site requirement. , d. Panic bar/ latch (double point) fitted with a single body, trim latch & lock on back side of the panic latch of reputed brand and manufacture to be approved by the Engineer-in-charge, Rate shall be inclusive of making cut-outs, provisions, etc for receiving Access Control provision

21

-

13606.64

... More
 Providing and fixing in position Factory-finished Single leaf Flush Doors of size 1050 mm width and 2400 mm height with Vision Panel as per drawing with Dorma/ approved equivalent make of Aluminium door frames of size 40x92mm. The frame finish shall be natural Anodized of 20 microns. Rate shall be inclusive of providing and fixing 35mm thick Factory-made Flush Door Shutters single leaf or two leaves solid core bonded with phenol formaldehyde synthetic resin thermo pressed with 8mm thick teak wood external lipping. The construction procedure of the shutter should be as per clause no.6 of IS 2202 (latest issue). The shutter shall be shop prepared for taking mortice lock or latches. Suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock covered in IS 2209 (latest issue). All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. Shutter to be finished with 1mm laminate of approved shade on both sides. Door shutters are to be fitted with the following hardware:- 3 Nos. of S.S butt hinges - 125 mm, Door set mortice lock with S.S plate - 6 levers - 1 No., Nylon door buffer of 35 mm dia - 1 No., S.S 'H' handle of 600 mm height - 1 No., S.S Door closer - 1 No. (slim pelmet arm type and of suitable load capacity)

22.68

-

6896.96

... More
 Providing and fixing in position Factory-finished Single leaf Flush Doors of size 900 mm width and 2400 mm height with Vision Panel as per drawing with Dorma/ approved equivalent make of Aluminium door frames of size 40x92mm. The frame finish shall be natural Anodized of 20 microns. Rate shall be inclusive of providing and fixing 35mm thick Factory-made Flush Door Shutters single leaf or two leaves solid core bonded with phenol formaldehyde synthetic resin thermo pressed with 8mm thick teak wood external lipping. The construction procedure of the shutter should be as per clause no.6 of IS 2202 (latest issue). The shutter shall be shop prepared for taking mortice lock or latches. Suitable lock block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock covered in IS 2209 (latest issue). All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. complete as directed. Shutter to be finished with 1mm laminate of approved shade on both sides. Door shutters are to be fitted with the following hardware:- 3 Nos. of S.S butt hinges - 125 mm, Door set mortice lock with S.S plate - 6 levers - 1 No., Nylon door buffer of 35 mm dia - 1 No., S.S 'H' handle of 600 mm height - 1 No., S.S Door closer - 1 No. (slim pelmet arm type and of suitable load capacity)

12.96

-

6553.86

... More
 Providing and fixing single action glass door with hinges using 12 mm thick frameless toughened glass of approved brand and manufacture, including providing and fixing Dorma make Junior Office Hinges (3 nos), studio gala locks and Dorma slide channel Door closer with saddle plate for fixing on the glass door and necessary seals to be provided all around the door frames and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

47.88

-

14126.48

... More
Partition works

-

-

-

... More
 Providing and fixing 100 mm overall thickness partition with 12.5 mm thick double skin fire rated board conforming to IS : 2095 : part I upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.

257.03

-

2756.54

... More
Providing and fixing Single glazed partitions of 12mm thick toughened glass as per Drawings using Full Height Dorma partition systems or approved equivalent and shall be able to provide a sound reduction of 36dB. The glass panels shall be supported by Aluminium WCP Profiles of 25x45mm on all 4 sides of the Glass partition perimeter. Glass-to-glass butt joints shall be done using Aluminium ' H ' profile for 12 mm glass, and corner glass junctions to have 90° corner Aluminium profile. At Glass perpendicular 'T' junctions, Aluminium T-junction profile to be used. Finishes of all aluminium frame components shall be Natural Anodized Finished (20 microns). At the location of doors, wideline section (100x25mm) shall be provided around the door two vertical upto false ceiling and horizontal at door top. Adjacent to the door frame, necessary service profile to be provided for installing the access control system as per requirement. Rate shall include for providing and fixing necessary support arrangement to ensure proper anchorage / fixing from the ceiling to get sufficient rigidity (to the required level). Rate shall include for transport charges, handling, loading and unloading, installation of glass and protecting the module and glass till handing over, testing, commissioning all necessary hardware, Structural supports, etc. complete and all as per manufacturers specifications as directed. the vendor has to prepare the shop drawing for client / Architects approval. Rate shall include for providing transport charges, handling, loading and unloading, installation, protecting the module and glass till handing over, testing, commissioning all necessary hardware's, scaffolding, wastage, etc complete as per directions of Engineer-in-charge Note : Only the clear elevation area below the false ceiling level shall be considered for measurement

233.57

-

5850.43

... More
 Providing and fixing Double-glazed partitions at Conference Room using Full Height Dorma partition systems or approved equivalent. Rate shall include for providing and fixing necessary support arrangement to ensure proper anchorage / fixing from the ceiling to get sufficient rigidity (to the required level). Rate shall include for transport charges, handling, loading and unloading, installation of glass and protecting the module and glass till handing over, testing, commissioning all necessary hardware’s, Structural supports, etc. complete and all as per manufacturers specifications as directed. Note : Only the clear elevation area below the false ceiling level shall be considered for measurement.

43.71

-

11288.08

... More
 Providing and fixing 75 mm overall thickness partition with 2 nos of 12.5 mm thick double skin fire rated board conforming to IS : 2095 : part I on one side upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.

5.85

-

1900.2

... More
 Providing and fixing partition made out of aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction covered with panelling one side with 12 mm thick fire retardant plywood conforming to IS: 5509 and other side with 12.5 mm thick tapered edge gypsum fire resistant board up to 75mm above false ceiling as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a paneling to any shape including circular profile etc. complete. Actual seen surface area.(i.e) from FFL to bottom of false ceiling height will be measured and paid.

66.89

-

4713.04

... More
 Providing and fixing partition made out of aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction covered with panelling on both sides with 12 mm thick fire retardant plywood conforming to IS: 5509 up to 75mm above false ceiling as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a paneling to any shape including circular profile etc. complete. Actual seen surface area.(i.e) from FFL to bottom of false ceiling height will be measured and paid.

66.92

-

5167.62

... More
 Providing and fixing partition above false ceiling made out of aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction covered with panelling one side with 12.5 mm thick tapered edge gypsum fire resistant board up to 75mm above false ceiling as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a paneling to any shape including circular profile etc. complete. Actual seen surface area.(i.e) from FFL to bottom of false ceiling height will be measured and paid.

422.91

-

3544.27

... More
 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge

774.6

-

357.77

... More
Providing & fixing Modular Toilet cubicles of MERINO BESCO make of TITAN 12mm STD SERIES or approved Equivalent - complete set including partitions and S.S 304 grade Accessories such as Top Rail, Coat hook with Door stopper, Occupancy indicator, Door Knob, 'U' Channel, 'F' Channel, screws, Adjustable Legs, etc complete and with Rubber strip for the groove in the Pilaster for reducing noise. The cubicle shall be of Pilaster & S.S Leg Floor-mounted type with overhead bracing taking into consideration the stability of the panels. Top bracing shall be connected to the wall for additional support and stability. Wall brackets and corner brackets to be used while assembling the cubicles. In addition, the door should have a self-closing hinge and an indicator slip latch or bolt with a knob outside and 2 coat hooks inside. Note: Contractor to submit shop drawing for approval before start of works. The panels and doors shall be constructed out of 12mm thick Compact Laminate of approved shade.a) Compartment depth & width: as per the drawings / site measurement b) Door width: 600 mm c) Overall Height : 1980 mm (including bottom gap of 150 mm)

14

-

30000

... More
 Supply & Fixing of Urinal Dividers of MERINO make of shape as per Drawing with 12mm Compact Laminate of approved shade fixed with S.S clamps, etc, as per manufacturer specifications.

10

-

5000

... More
Miscellaneous design works

-

-

-

... More
 Providing and fixing etching to glass panels using 3M frosted film (sparkling type) of Code No. 7725 with 15 years warranty, as per required pattern and design and as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment.

171

-

1031.01

... More
 Providing and fixing etching to glass panels using 3M film (Code No. 7725 with 5 years warranty) of approved color printed graphics as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment.

10

-

1772.99

... More
 Providing and fixing of Vinyl Graphics on walls / partitions using 3M film (Code No. IJ180C with 5 years warranty) as per approved design and at specified locations as directed by Architect / Client. The rate shall be inclusive of preparing the base surface with 2 coats putty, and 1 coat oil primer with smooth finish, all complete and as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment.

25

-

3292

... More
 Providing and laying of premium quality Wallpaper of approved make and design over partition / panelling / wall surfaces. Rate to include preparation of base surface with 2 coats putty, and 1 coat oil primer with smooth finish, all complete and as directed. Rate shall be inclusive of all wastages, etc. Note : Only the actual installed area shall be measured for payment. Note : Basic rate of Wallpaper = Rs.60/- per sft.

122

-

1046

... More
 Providing and fixing of roller blinds with chain driven system with total Block-out Fabric of approved shade made of 100% polyester, Fabric width upto 200/250 cm, Fabric weight 290-310 g/sq.m, Thickness 0.57mm and Colour Fastness 6, installed as per Manufacturer's instruction. of approved make (Hunter Douglas Roller shades/ PHIFER / VISTA or equivalent) as per manufacturer's specification etc complete as per directions of Engineer-in-charge .

131

-

1238

... More
 Supply & Fixing of 9mm thick PET Acoustic Panels of approved make on Partition / Masonry wall surface as per Drawings and as directed using appropriate adhesive as per manufacturer instructions. The rate shall be inclusive of preparing the base surface, all wastages, etc. Note : Only the actual installed area shall be measured for payment.

115

-

2967.01

... More
 Supply & Fixing of free-standing suspended Designer laser-cut 9mm thick PET Acoustic Panels of approved make as per Drawings with S.S string support from ceiling and with 'U'-profile support. Rate shall also be inclusive of S.S 304 leg supports (2 nos. per panel) fixed from the floor level. The size of each panel shall be 900mm X 1850mm X 9mm. The rate shall be inclusive of the necessary supports from the true ceiling level, all wastages, etc complete and as directed.

5

-

8362.8

... More
 Supply and fixing of Brick 'A' Series Design No. 308317 MCM - Modified Clay Material of PHOMI make or approved equivalent, Eco friendly Building Material, manufactured through unfired patented (Ref: US patent 8505840 B2 & European Patent 2157139) manufacturing technology, bonded together by using low heat temperature and having CE approval. The material should be flexibile, having good impact resitance, water resistant, Fire resistant and durable with a min. warranty of 10 years. MCM Phomi cladding panels to be fixed with suitable PU, Cement, Polymer based adhesive depending on the substrate with either Kerakol, Latecrete, Roffe, Pidilite. The material should be suitable for fixing on exterior, interior, flooring, ceiling, furniture covering and landscaping. Rate shall be inclusive of grouting of approved shade with required filling and pointing method to be used. For wet areas, MCM Phomi panels to be fixed with resin based adhesive to avoid efflorescence. For all flooring, bathroom and kitchen walls and wet area applications, protective PU coat to be used. The materials should have Abrasion resistance as per ASTM C241/C241M-15 of 8. Gray Scale value of 4 under ASTM G154-12a Cycle 1 & ASTM D2244-15a & ASTM D2616-12. Static Coefficient of fricton as per ASTM C1028-07, Dry condition 1.11 and wet condition 0.70. Chemical Resistance as per ANSI Z124.6-2007 clause 5.20 with total rating of 76 and maximum stain depth 0.101mm. Water absorption ASTM C97/C97M-15 12.40 and Bulk specific gravity of 1.83 The product should be certified by Singapore Environment Council as Eco Friendly Building Material.

42

-

2235.89

... More
 Providing and Fixing of Anodised Aluminium 5mm Groove channels (Hat section) of approved make in natural anodized finish, as per drawing and as directed. Rate shall be inclusive of all hardware, wastages, etc complete and as directed.

245

-

301

... More
 Providing and Fixing of Anodised Aluminium 12 x 12 mm Corner Guards of approved make in natural anodized finish, as per drawing and as directed. Rate shall be inclusive of all hardware, wastages, etc complete and as directed.

35

-

301

... More
 Providing and Fixing of Anodised Aluminium Recessed Pen Tray of Kubik make : Model No. KS-PT-001-AL or app. equivalent in natural anodized finish, of 450mm length and as directed. Rate shall be inclusive of the corresponding end caps : Model No. KS-EC-10, all hardware, wastages, partition modifications to accommodate the recessed fixture, etc complete and as directed.

19

-

3904

... More
 Providing and Fixing of Reception signage of approx 1800 x 750 mm size (as per the design given by Client team) & following the standard Signage spec of the Client for the lettering, colour, font size, etc.The Logo shall be in Vinyl and the Text shall be in S.S - both 50mm thick and fixed directly on the partition, and with LED concealed back-lighting. Rate to include for providing adequate support for fixing the same, wiring provision for the backlighting, etc, complete.

2.7

-

18388.98

... More
 Providing and Fixing of Room Nomenclature Signages of S.S finish with Acid etched lettering of approved shade and of size 400 x 100 mm. Names of rooms to be confirmed by Client. The S.S signage shall be pasted using double-sided tape of 3M make on the Glass doors / Flush doors.

38

-

1535

... More
 Providing and Fixing of Door PUSH / PULL Signages of S.S finish with Acid etched lettering of approved shade and of size 400 x 100 mm. The S.S signage shall be pasted using double-sided tape of 3M make on the Glass doors / Flush doors.

74

-

437

... More
Carpentry/Furniture works

-

-

-

... More
 Providing and fixing Reception table in facility at third floor made to shape and design as per drawing, of dimensions 1900 x 750 mm and to a height of 750 / 1050 mm, but in general it shall be made of 19 mm thick comm. plywood as table top, sides, front and rear side with adequate supports as directed in both horizontal and vertical directions. The table shall be provided with modular mobile pedestal storage unit (3 drawer) as per drawing, and 1 no. powder-coated metal CPU trolley, etc. complete. Rate shall be inclusive of supply and fixing of 12mm thick Solid Acrylic surface of app. make for the countertop and all fascia surfaces as per the drawing. In addition, all recessed surfaces of the table shall be finished with 1mm laminate of approved make & shade. Rate shall also include for supply and fixing of 6mm lacquered glass of approved make with 3M double-side tape as per the drawing.Rate shall include for providing and fixing necessary hardware, Hinges, S.S 'H' handles, telescopic slides, MS powder coated wire manager – 75 mm dia, teakwood lipping / moulding duly melamine polished to a specified size as required. Rate to include all hardwares including locking facility with one master key for all drawers of approved make and ISI mark etc. complete.

1

-

61164.1

... More
 Providing and fixing Reception table in facility at fourth floor made to shape and design as per drawing, of dimensions 1900 x 750 mm and to a height of 750 / 1050 mm, but in general it shall be made of 19 mm thick comm. plywood as table top, sides, front and rear side with adequate supports as directed in both horizontal and vertical directions. The table shall be provided with modular mobile pedestal storage unit (3 drawer) as per drawing, and 1 no. powder-coated metal CPU trolley, etc. complete.Rate shall be inclusive of supply and fixing of 12mm thick Solid Acrylic surface of app. make for the countertop and all fascia surfaces as per the drawing. In addition, all recessed surfaces of the table shall be finished with 1mm laminate of approved make & shade. Rate shall also include for supply and fixing of 6mm lacquered glass of approved make with 3M double-side tape as per the drawing. Rate shall include for providing and fixing necessary hardware, Hinges, S.S 'H' handles, telescopic slides, MS powder coated wire manager – 75 mm dia, teakwood lipping / moulding duly melamine polished to a specified size as required. Rate to include all hardwares including locking facility with one master key for all drawers of approved make and ISI mark etc. complete.

1

-

62789.28

... More
 Providing & fixing Wall Panelling as per Drawings, in general, with 12 mm thick comm. ply and finished with 6mm thick lacquered glass of app. make and of approved shade as per pattern and details given in drawing. The lacquered glass shall be fixed using 3M double-sided tape or clear, neutral Silicone sealant. The edges shall be chamfered so as to get 'V'-Groove with the adjoining glass panel.The panelling shall be as per the Elevation drawing with the required cut-outs for the electrical switch plates and LCD TV, etc all complete as directed and to the satisfaction of the Architect / Client. Rate to include all wastages, necessary supports & backing to ensure rigidity, levels & plumb, etc complete.a) for 6mm thick lacquered glass fixed directly over existing plywood partition base. (Note: Shop drawing shall be submitted to Architect for approval before fixing the glass).

90.2

-

3021.03

... More
 Providing & fixing Wall Panelling as per Drawings, in general, with 12 mm thick comm. ply and finished with 6mm thick lacquered glass of app. make and of approved shade as per pattern and details given in drawing. The lacquered glass shall be fixed using 3M double-sided tape or clear, neutral Silicone sealant. The edges shall be chamfered so as to get 'V'-Groove with the adjoining glass panel.The panelling shall be as per the Elevation drawing with the required cut-outs for the electrical switch plates and LCD TV, etc all complete as directed and to the satisfaction of the Architect / Client. Rate to include all wastages, necessary supports & backing to ensure rigidity, levels & plumb, etc complete. b) for 6mm thick lacquered glass fixed over 12mm comm. Ply panelling base fixed over masonry walls (rate to be considered inclusive of 12mm ply, all hardware, treatment of base surface, etc, complete)..(Note: Shop drawing shall be submitted to Architect for approval before fixing the glass).

3.26

-

4399.89

... More
 Providing & fixing Wall Panelling as per Drawings, in general, with 12 mm thick comm. ply and finished with 6mm thick lacquered glass of app. make and of approved shade as per pattern and details given in drawing. The lacquered glass shall be fixed using 3M double-sided tape or clear, neutral Silicone sealant. The edges shall be chamfered so as to get 'V'-Groove with the adjoining glass panel.The panelling shall be as per the Elevation drawing with the required cut-outs for the electrical switch plates and LCD TV, etc all complete as directed and to the satisfaction of the Architect / Client. Rate to include all wastages, necessary supports & backing to ensure rigidity, levels & plumb, etc complete.c) for 6mm thick lacquered glass fixed over 19mm comm. Ply panelling base fixed over masonry walls (rate to be considered inclusive of 19mm ply, all hardware, treatment of base surface, etc, complete)..(Note: Shop drawing shall be submitted to Architect for approval before fixing the glass).

4.071

-

4317.82

... More
 Providing & fixing Wall Panelling of various thicknesses as per Drawings, in general, it shall be made out of Exterior Grade MDF. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. a) for 12mm thick Exterior Grade MDF finished on all sides with Vinyl Graphics of approved design over 2 coats putty, and 1 coat oil primer with smooth finish as prepared surface, all complete and as directed. (Rate inclusive of Vinyl Graphics - specs as per Item 9.04) (Note: Only the Front Elevation area shall be considered for measurement)

14.69

-

4177.97

... More
 Providing & fixing Wall Panelling of various thicknesses as per Drawings, in general, it shall be made out of Exterior Grade MDF. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. b) for 19mm thick Exterior Grade MDF finished with 9mm thick Acoustic PET Panel of approved shade, all complete and as directed. (Note: Only the Front Elevation area shall be considered for measurement)

8.51

-

3927.99

... More
 Providing & fixing Wall Panelling of various thicknesses as per Drawings, in general, it shall be made out of Exterior Grade MDF. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. c) for 12mm thick Exterior Grade MDF finished on all sides with Wallpaper of approved design over 2 coats putty, and 1 coat oil primer with smooth finish as prepared surface, all complete and as directed.(Note: Only the Front Elevation area shall be considered for measurement) Note : Basic rate of Wallpaper = Rs.60/- per sft.

2.8

-

1713.2

... More
 Providing & fixing Wall Panelling of various thicknesses as per Drawings, in general, it shall be made out of Exterior Grade MDF. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. d)25mm thk MDF painted with 2 coats of low VOC Premium emulsion paint of approved make and shade over 1 coat of primer suitable for MDF & 2 coats of acrylic putty, and all as per manufacturer’s specification etc complete and all as directed. (Note: Only the Front Elevation area shall be considered for measurement)

4.12

-

1445.77

... More
 Providing & fixing Wall Panelling of 12 mm comm. ply as per Drawings, and finished with 1mm laminate of app. design, all complete and as directed. The exposed edge thickness shall be finished with T.W beading and polished to matching shade of the laminate. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. (Note: Only the Front Elevation area shall be considered for measurement)

4.162

-

3299.77

... More
 Providing & fixing Wall Panelling of 25 mm comm. ply as per Drawings, and finished with 1mm laminate of app. design, all complete and as directed. The exposed edge thickness shall be finished with T.W beading and polished to matching shade of the laminate. Rate to include all wastages, levelling of the base surface for proper plumb, etc complete and as directed. (Note: Only the Front Elevation area shall be considered for measurement)

4.403

-

3696.83

... More
 Providing and fixing of 6mm mirror over 12mm PVC panel of approved make with S.S studs at Handwash area. The mirror shall be provided with polythene sheet backing so as to avoid direct contact of moisture with the silver coating on the mirror rear side. Rate shall be inclusive of all hardware, labour, etc, complete.

14.624

-

3776.64

... More
 Providing and Fixing of Storage unit below wash basin counters as per Drawings. In general, the storage unit shall be made of 19mm thick PVC panel of approved make on all sides, and shall include 1 adjustable 19mm PVC panel shelf inside. All exposed surfaces shall be finished with 1mm laminate of approved shade, and all inner / recessed PVC panel surfaces shall be left exposed. Rate to include all hardware, tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete. Rate to include for 50mm end granite beading along the outer perimeter of the counter-top. The beading shall have R-10 corner edges along the top and bottom edges as per the drawing. Rate to include all hardware, MS brackets for support from the masonry wall, etc complete. Rate to include cutting of counter-top for accomodating the Washbasin bowl and CP fittings, and fixing the granite end beading with bull nosing to the cut-perimeter to neat finish. Basic rate of Granite : Rs.234/- per sft. Note: Only the Front Elevation area shall be considered for Measurement.

8.316

-

15743.1

... More
 Providing and fixing Storage unit in Conference room of 600 mm depth and 750 mm height as per Drawing, but in general, it shall be made out of 19 mm thick commercial plywood on all sides. The countertop shall be finished with 19mm thick granite. The storage unit shall include 1 no. of adjustable intermediate shelf made of 19mm comm. plywood placed on necessary S.S stud supports. The openable shutter shall be FACTORY-FINISHED and made out of 19mm thick comm. plywood with necessary teakwood lipping, supports, etc complete and finished with 1mm laminate of approved shade. Rate shall include for providing Granite Beading of size 40 x 15mm at top level etc. complete as per drawing. All inner / recessed surfaces shall be painted with sealer finish. Rate to include all hardware, S.S tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete. Note: Only the Front Elevation area shall be considered for Measurement. Basic rate of Granite = Rs.234/- per sft.

6.486

-

17850.84

... More
 Providing & Fixing Cafeteria / Pantry counter with storage as per Drg., in general, the storage shall be of 600mm depth and 850 mm height. The cabinets & shutters shall be FACTORY-FINISHED and made of 19mm PVC panel finished with 1mm laminate of approved shade. The storage unit shall include 1 no. of adjustable intermediate shelves as per the drawing made of 19mm PVC panel placed on necessary S.S stud supports. Rate to include all hardware, tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete. Rate to include for Providing & fixing 19mm thick Granite counter-top of approved shade over 19mm thick BWR ply. Rate to include for 40x15mm end granite beading along the outer perimeter of the counter-top. The beading shall have R-5 corner edges along the top and bottom edges as per the drawing. Rate to include all hardware, etc complete. Rate to include cutting of counter-top for accomodating the S.S sink and CP fittings and fixing the end beading to the cut-perimeter to neat finish. Basic rate of Granite : Rs.234/- per sft.Note: Only the Front Elevation area shall be considered for Measurement.

4.633

-

18201.79

... More
 Providing & Fixing Pantry Overhead storage as per Drg., in general, the storage shall be of 450mm depth and 600 mm height. The cabinets & shutters shall be FACTORY-FINISHED and made of 19mm comm. ply finished with 1mm laminate of approved shade. The storage unit shall include 1 no. of adjustable intermediate shelf as per the drawing made of 19mm comm. ply placed on necessary S.S stud supports, and finished with 1mm laminate of app. shade on both sides. Rate to include all hardware, tower bolt, magnetic catch, heavy duty hinges, S.S handles - of approved make, including locking arrangements with master key of approved make etc. complete.Note: Only the Front Elevation area shall be considered for Measurement.

0.54

-

13688.5

... More
 Providing & fixing Column Cladding as per Drg., in general, it shall be made out of aluminium box frame of size 100 x 50 mm x 1.5mm guage thickness covered with 12.5 mm thick gypboard to required shape as per the detail drawing. Exposed portions of the gypsum board panelling shall be finished with 2 coats of low VOC Premium emulsion paint of approved make and shade over 1 coat of primer suitable for MDF & 2 coats of acrylic putty, and all as per manufacturer’s specification etc complete and all as directed. Rate to include all hardware, wastages, etc complete. Note: Only the clear front elevation of all the Column sides shall be considered for measurement.

55.84

-

5093.17

... More
 Providing & fixing Column Cladding as per Drg., in general, it shall be made out of aluminium box frame of size 100 x 50 mm x 1.5mm guage thickness covered with 12.5 mm thick gypboard to required shape as per the detail drawing. Exposed portions of the gypsum board panelling shall be finished with Gypboard With Vinyl Graphics over 1 coat of primer suitable for MDF & 2 coats of acrylic putty, and all as per manufacturer’s specification etc complete and all as directed. Rate to include all hardware, wastages, etc complete.Note: Only the clear front elevation of all the Column sides shall be considered for measurement.

33.04

-

8285.13

... More
 Decorative Divider Partition - Pantry - Providing & fixing hollow wooden vertical & horizontal framework of size 60 x 100mm, made of 12 mm comm. ply on all sides finished with 1 mm laminate of approved shade. Rate to include fixing at the ceiling level as per design and as directed with adequate framework to support from the RC slab. Rate to include making of grooves as per Architect's instructions, all hardware, etc complete as directed.

33.6

-

1409.16

... More
 Providing and fixing 8 mm thick toughened glass of size and shape as indicated in the required locations and fixed with S.S 'D' brackets. Rate to include for edge polishing of glass, protecting the glass until handover, all wastages, etc complete.

4.25

-

3458.37

... More
 Providing & fixing Wooden Fins of dimensions 25 x 100 mm made of 25 mm comm. ply finished with 1 mm laminate of approved shade. Rate to include fixing at the ceiling level as per design and as directed with adequate framework to support the fins from the RC slab. Rate shall be inclusive of all hardware, wastages, etc, complete.

43.2

-

696.53

... More
 Providing and Fixing Concealed Shaft Door as per Drawing, made of 19mm comm. ply and finished with 1mm laminate of app. Design on both sides. Rate shall be inclusive of all hardware such as concealed hinges, magnetic catch, dead lock, wastages, etc, complete.

0.9

-

4752.92

... More
 Providing and Fixing Planter Box of 300mm height and 200mm depth as per Drawing, made of 19mm comm. ply and finished with 1mm laminate of app. design. Rate shall be inclusive of all hardware, wastages, etc, complete.

1.75

-

3129.98

... More
 Providing and Fixing Planter Box of 1000mm height and 200mm depth as per Drawing, made of 19mm comm. ply and finished with 1mm laminate of app. design. The top countertop of the Planter box shall be recessed by 150mm. Rate shall be inclusive of all hardware, wastages, etc, complete.

3.45

-

5677.23

... More
 Providing & fixing Wall Panelling of 100mm depth as per Drawing, in general, it shall be made out of aluminium box frame of size 50 x 25 mm x 1.5mm guage thickness covered with 12 mm thick comm. Ply and finished with 6mm lacquered glass of approved shade.Rate to include all wastages, provision for LED cove lighting as per the drawing detail, etc, complete and as directed. (Note: Only the Front Elevation area shall be considered for measurement)

25.732

-

9043.47

... More
 Providing & fixing Wall Panelling of 100mm depth as per Drawing, in general, it shall be made out of aluminium box frame of size 50 x 25 mm x 1.5mm guage thickness covered with 18 mm thick Exterior grade MDF. The MDF shall be finished with 2 coats of low VOC Premium emulsion paint of approved make and shade over 1 coat of primer suitable for MDF & 2 coats of acrylic putty, and all as per manufacturer’s specification etc complete and all as directed. Rate to include all wastages, provision for LED cove lighting as per the drawing detail, etc, complete and as directed. (Note: Only the Front Elevation area shall be considered for measurement)

18.9

-

5769.51

... More
 Providing and fixing Pelmet for concealing the pull-down projector screens. The pelmet shall be made of 19mm thick comm. ply finished with enamel paint of approved shade. It shall be of 'U' shape of size 150 x 150 mm and its bottom level shall be fixed flush with the adjoining false ceiling level so as to recess the pelmet. Rate to include all hardware and supports for sufficient rigidity and to receive the false ceiling perimeter channels.

10.07

-

1548.85

... More
Sanitary, water supply and drainage works

-

-

-

... More
 Providing and fixing Stainless Steel A ISI 304 (18/8) Kitchen sink with drain board 510x1040 mm bowl depth 250 mm as per IS 13983 with C.I. brackets , 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required, grouting the joints etc complete as per directions of Engineer-in-charge

2

-

10832.04

... More
 Supplying, installing, testing and commissioning of glazed under counter wash basin (Hindware make model Garnet cat. no. 10080 or equivalent), with pressmatic pillar cock (Jaquar make model no. PRS-031L65 or equivalent) , CP waste with overflow (pop-up), 32mm dia CP bottle trap with extension pipe, supporting CI bracket to support basin, 1 No. 15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges, all complete set of approved make. 

16

-

9089.45

... More
 Providing, fixing, testing and commissioning of white vitreous china glazed wall mounted water closet (European type) of approved make (Jaquar make Continental series cat no:CNS-WHT-963NN or equivalent) With concealed cistern (Jaquar make code JCS-WHT-2400S or equivalent) and flushing plate (Jaquar make code : JCP-CHR-392415 or equivalent) with necessary water connection with integrated angle stop valve production cover for service opening to be cut to the length, WC outlet bend, WC connection set dia 90mm, 2 threaded rods M12 for ceramics fastening,4adjustable fastening brackets, with fastening materials, with actuator plate, complete and the EWC shall be with necessary check nut, stopcock etc., seat and lid, CP brass hinges and rubber buffers, Concealed flushing cistern with fittings supporting bolt /CI / MS brackets. etc. cutting and making good the walls and floors wherever required all complete as per specification and direction of the Engineer-in-charge

14

-

18585.19

... More
 Providing and fixing white vitreous urinal of approx. size 540x315x300mm with inlet from back side and pressmatic auto closing concealed urinal flush valve with wall flange, with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required, fixing to wall with suitable brackets all as per manufacturers specification and as per directions of Engineer-in-charge

13

-

12752.54

... More
 Supplying and fixing CP Sink cock superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

2

-

1300.41

... More
 Providing and fixing CP Brass toilet paper holder of superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

14

-

539.07

... More
 Providing and fixing 20 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.

60

-

398.48

... More
 Providing and fixing 25 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.

18

-

466.67

... More
 Providing and fixing 32 mm nominal outer diaChlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.

12

-

577.61

... More
 Providing and fixing 40 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall

24

-

539.28

... More
 Supplying and fixing CP Angle cock superior quality (Jaguar or equvalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge

16

-

556.94

... More
 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

14

-

1280.45

... More
 Providing, fixing and testing of approved make of 110 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, 'y' , coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete. 

54

-

563.51

... More
 Providing, fixing and testing of approved make of 75 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, 'y' , coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete. 

54

-

439.69

... More
 Providing, fixing and testing of approved make of 50 mm dia SWR - B- Class PVC pipes and fittings confirming to IS 13592-1992. and fittings (available fittings in market and fabricated fittings ) such as tee, elbow, 'y' , coupler, etc. conforming to 14735 with latest amendment for soil and waste pipe works in toilets and utility area,etc. Pipes shall be laid in vertical stack and sunken in floors as per approved drawings with proper alignment and gradient as per the drawings with proper split clamp,anchor fastener and 10 mm thread rod supports. Wall cutting shall be done using wall cutting machine, and chasing to be done using electric jack hammer machine. Cutting and chasing with hammer shall not be permitted. Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and get the approval from the Engineer-in-charge. Chased portions shall be covered with cement mortar. Work includes making required size holes in brick walls wherever necessary and re do same with water proofing components to the entire satisfaction of Engineer-in-charge.etc complete. All the stub outs shall be closed with proper end caps till of installation of sanitary wares and accessories etc. complete. 

48

-

380.8

... More
 Supplying, fixing and testing of PVC floor trap with CP grating, 150mm nominal size square, 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 110 dia with the extension boss tee connections, fixed in floors or etc., complete.

26

-

3077.67

... More
 Making connection of drain or sewer line For pipes 100 to 250 mm diameter with existing pipeline/ manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.

5

-

547.18

... More
Electrical - Light Fixtures

-

-

-

... More
 Supply, Installation, Testing and Commisioining of High performance, Recess mounted 36W 2X2 LED light fitting. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions.(as per the wipro Cat No: CRCO-10R0 38 HP57 or equivalant type)

54

-

5356.18

... More
 Supply, Installation, Testing and Commingling of decorative type LED fittings 15W. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by architect/consultant.(pantry) Wipro make model no:LD99-211-XXX57PMWH or equivalent

12

-

3550.05

... More
 Supply, Installation, Testing and Commissioning of decorative type LED fittings 10 W. The supply of accessories like clamps, supporting brackets and hardware as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by architect/consultant.(Reception) Wipro make model no: LD30-101-36B-40-PL or equivalent

15

-

4186.55

... More
 Supply, Installation, Testing and Commissioning of 15W LED recess down light fitting with all accessories and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire and fixing the same in the ceiling / partition as per site conditions. (as per the wipro Cat No: LD71-161SML-65-XX or equivalent type)

190

-

1742.76

... More
 Supply, Installation, Testing and Commissioning of single 4 Feet feet patty type fittings with all accessories like low loss ballast along with 2x20w Triphosphorous coat high lumen lamps and fixing the same in the wall / ceiling with wooden blocks, screws ,hardwaresas required as per the site conditions)(Cat Ref No: WIO92 or equivalant type)

8

-

573.13

... More
 Supply,Installation, Testing and Commissioning of single 4 feet 30 W LED Linear recessed type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per the site conditions (Including the earthing of fixture) (as per the Wipro Cat No: LM30-401-XXX-57-G1 or equivalant type)

40

-

6216.87

... More
 Supply,Installation, Testing and Commissioning of single 4 feet 30 W LED Linear Suspended type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per the site conditions (Including the earthing of fixture) (as per the Wipro Cat No: LM31-401-XXX-57-XXor equivalant type) watts

86

-

6388.76

... More
 Supply,Installation, Testing and Commissioning of single 8 feet 30 W LED Linear recessed type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per the site conditions (Including the earthing of fixture) (as per the Wipro Cat No: LM30-401-XXX-57-G1CT or equivalent type)

29

-

6302.81

... More
 Supply,Installation, Testing and Commissioning of single 8 feet 30 W LED Linear Suspended type fittings with all accessories Copper ballast and 2.5 mtr hanging chain required as per the site conditions (Including the earthing of fixture) (as per the Wipro Cat No: LM31-401-XXX-57-CT or equivalant type)

1

-

6423.6

... More
Wiring for luminaries

-

-

-

... More
 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

200

-

766.6

... More
 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B

155

-

860.32

... More
 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

100

-

1058.97

... More
 Wiring for circuit/ submain wiring alongwith earth wire with 2x1.5 sq.mm + 1x1.5 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / ecessed medium class PVC conduit as required

700

-

156.68

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / ecessed medium class PVC conduit as required

1500

-

191.65

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / ecessed medium class PVC conduit as required

50

-

235.02

... More
Wiring for circuit/ submain wiring alongwith earth wire with 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / ecessed medium class PVC conduit as required

50

-

317.55

... More
Power Switch & Socket

-

-

-

... More
 Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

795

-

117.51

... More
 Supplying and fixing 15/16 amp modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

55

-

159.47

... More
 Supplying and fixing 3 pin 5/6 amp modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

795

-

113.31

... More
 Supplying and fixing 6 pin 15/16 amp modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

55

-

214.03

... More
 Supplying and fixing of 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc as required.

45

-

244.81

... More
 Supplying and fixing 3 Module (100mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc as required.

100

-

258.8

... More
 Supplying and fixing of 4 Module (125mmX75mm)s, GI box alongwith modular base & cover plate for modular switches in recess etc as required.

120

-

286.77

... More
 Supplying and fixing of 6 Module (200mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc as required.

255

-

360.92

... More
 Supplying and fixing 8 Module (125mmX125mm), GI box alongwith modular base & cover plate for modular switches in recess etc as required.

20

-

415.47

... More
 Supply, Fixing, Testing and Commissioning of 25A, 3 pin industrial type interlocked switched socket outlet with with 25A DP MCB also 3c,4 sqmm cu.cable of 6 meter to be provided with termination and is supporting accessories and surface mounting box of IP 44 degree of protection with plug top and other associated accessories as required as per

10

-

2302.92

... More
 Supply, Fixing, Testing and Commissioning of 63 A TPN MCB enclosed in weather proof Enclosure with and other associated accessories as required as per the site conditions.

10

-

3300.7

... More
 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

5

-

877.11

... More
UPS/RAW POWER WIRING

-

-

-

... More
 Supply and drawing of 3 core 2.50 sq mm for ups socket(white colour) of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections.

3600

-

96.4

... More
 Supply and drawing of 3 core 2.50 sq mm for Raw power socket in black colour of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections.

2250

-

96.4

... More
 Supply and drawing 3 core 4.00 sq mm of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections.

40

-

136.99

... More
UNDER FLOOR CABLE MANAGEMENT SYSTEM

-

-

-

... More
 Supply, Fixing of Aluminium Trunking box of 1.6 mm thick and should be earthed every 3 meters with 2.5 sq mm copper wire, 60 MM floor cutting, plastering Clamps and all other accessories as required as per the site condition for fixing the same with 100 x 45 mm Aluminium Channel (the proper couplers to be used in between the joining of raceways)-

700

-

360.42

... More
 Supply, Fixing, Erection of Powder coated MS Junction box of 150 x 150 x 50 mm.The MS junction box shall be earthed with 2.5 sqmm copper wire with all hard wares and accessories as required including all clamps and hard wares for fixing the same. The proper supporting to be provided in the center of the Junction Boxes. The Junction to be covered all other sides, excluding the entry side. The junction thickness is 2 mm and top cover 3 mm.

106

-

286.24

... More
 Supply, Fixing, Erection of Powder coated MS Junction box of 250 x 250 x 50mm.The MS junction box shall be earthed with 2.5sqmm copper wire with all hardwares and accessories as required including all clamps and hardwares for fixing the same. The proper supporting to be provided in the centre of the Junction Boxes. The Junction to be covered all other sides, excluding the entry side. The junction thickness is 2mm and top cover 3mm.

30

-

382.98

... More
 Supply, Fixing, Erection of Powder coated MS Junction box of 350 x 350 x 50 mm.The MS junction box shall be earthed with 2.5 sq mm copper wire with all hard wares and accessories as required including all clamps and hard wares for fixing the same. The proper supporting to be provided in the center of the Junction Boxes. The Junction to be covered all other sides, excluding the entry side. The junction thickness is 2 mm and top cover 3 mm.

16

-

583.92

... More
 Supply, Fixing, Erection of Powder coated MS Junction box of 450 x 450 x 50mm. The MS junction box shall be earthed with 2.5sqmm copper wire with all hardwares and accessories as required including all clamps and hardwares for fixing the same. The proper supporting to be provided in the center of the Junction Boxes. The Junction to be covered all other sides, excluding the entry side. The junction thickness is 2mm and top cover

30

-

859.62

... More
SECONDARY DISTRIBUTION SYSTEMS

-

-

-

... More
 Supply, Installation, Testing and Commissioning of three phase, phase segregated, compartmentalized 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Incomer - 63A TPN MCB - 1 No,Phase Incomer - 32A 30mA DP ELCB/RCCB - 3Nos, Outgoings - 6A SP MCB - 24 Nos Including all interconnections and other associated fixing accessories etc as required as per the site conditions.

3

-

19673.85

... More
 Supply, Installation, Testing and Commissioning of three phase, phase segregated, compartmentalized 12 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incomer - 63A TPN MCB - 1 No, Phase Incomer - 63A 30mA DP ELCB/RCCB - 3Nos, Outgoings - 16A SP MCB - 36Nos, Including all interconnections and other associated fixing accessories etc, as required as per the site conditions.

2

-

44328.34

... More
 Supply, Installation, Testing and Commissioning of three phase, phase segregated, compartmentalized 12way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPS DB. Incomer - 63A TP+2N MCB - 1 No, Phase Incomer - 63A DP MCB - 3Nos, Outgoings - 16A SP MCB - 36 Nos, Including all interconnections and other associated fixing accessories etc as required as per the site conditions.

3

-

44328.34

... More
 Supply, Installation, Testing and Commissioning of single phase, 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for EMERGENCY LDB. Incomer - 32A DP ELCB - 1 No, Outgoings - 6A SP MCB - 7 Nos, Including all interconnections and other associated fixing accessories etc as required as per the site conditions.

2

-

8422.78

... More
 Supply, Installation, Testing and Commissioning of Three phase, 4way TPN MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for HUB UDB. Incomer - 63A TP+2N MCB - 1 No, Outgoings -25A SP MCB - 12Nos, Including all interconnections and other associated fixing accessories etc as required as per the site conditions.

4

-

17288.29

... More
PRIMARY DISTRIBUTION SYSTEM

-

-

-

... More
 UPS i/P PANEL- Supply, Erection, Testing and Commissioning of Indoor type Floor Power panel floor mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalized, all MCCB shall have inbuilt shunt trip coil arrangement and All MCCBs of 250A and above for non-ups loads will be microprocessor based , CTs shall be with dual ratio and cast resin type only with modular type IP 42 Protection with powder coated panel with Incomer: 1 Nos - 100A TPN MCCB , 1 Set of Current transformer rated 110/5A, 10VA/CI 1.0 for metering, 1 No – Digital Multi data Meter with RS 485 , 1 Set – LED type RYB indication lamps with control fuses Incoming breakers shall have LED 'ON / OFF / TRIP' , 1 Set - ELR with CBCT.(500mA S), 1 No of TVSS 16kA connected to the Bus Bar. Outgoing: 6 Nos - 63A TPN MCCB ,with 100A Aluminium Bus Bar and Associated Accessories as required.Incoming and outgoing cables shall be of Top entry only.CTs shall be with dual ratio and cast resin type only, All doors to have rubber gasket with shutter assembly & door seating frame.All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases.

1

-

124032.46

... More
 Supply, Erection, Testing and Commissioning of Indoor type UPS OUTGOING PANEL, Floor/Wall mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalized, cable entry shall be in both top and bottom, All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases. , CTs shall be with dual ratio and cast resin type only. with modular type IP 42 Protection with powder coated panel as specification below and it CT should connected in common main bus. All MCB should be 'D' curve.Incomer: 3 Nos 63A TP+2N MCCB (Neutral should be 200% of the Phase Current), 3 Sets of Current transformer rated 60/5A, 10VA/CI 1.0 for metering at common bus., 1Nos – Digital Multi data Meter with RS 485 (suitable to measure harmonics) at common bus.1Sets – LED type RYB indication lamps with control fuses, Incoming breakers shall have LED 'ON / OFF / TRIP' .Outgoing: 4Nos - 63A TP+2N MCB , 100A PHASE & NEUTRAL Copper Bus Bar and Associated Accessories as required. (Neutral should be 200% of the Phase Current). Incoming and outgoing cables shall be of Top& Bottom entry.CTs shall be with dual ratio and cast resin type only.All doors to have rubber gasket with shutter assembly & door seating frame.All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases.

1

-

137215.49

... More
 Supply, Erection, Testing and Commissioning of TOD 3 phase Energy meter & CT 200/5A, 10VA/CI 1.0 for metering with enclosure. L&T make ,tested by electrical inspectorate

2

-

22798.87

... More
 Supply, Erection, Testing and Commissioning of Indoor type UPS OUTGOING PANEL, Floor/Wall mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalized, cable entry shall be in both top and bottom, All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases. , CTs shall be with dual ratio and cast resin type only with modular type IP 42 Protection with powder coated panel as specification below and it CT should connected in common main bus. All MCB should be 'D' curve.Incomer: 3 Nos 63A TP+2N MCCB (Neutral should be 200% of the Phase Current), 3 Sets of Current transformer rated 60/5A, 10VA/CI 1.0 for metering at common bus.1Nos – Digital Multi data Meter with RS 485 (suitable to measure harmonics) at common bus.1Sets – LED type RYB indication lamps with control fuses, Incoming breakers shall have LED 'ON / OFF / TRIP' , Outgoing: 4Nos - 63A TP+2N MCB, 100A(TP+2N) PHASE &DOUBLE NEUTRAL Copper Bus Bar and Associated Accessories as required. (Neutral should be 200% of the Phase Current). Incoming and outgoing cables shall be of Top& Bottom entry.CTs shall be with dual ratio and cast resin type only. All doors to have rubber gasket with shutter assembly & door seating frame.All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases.

1

-

148316.68

... More
POWER CABLES AND CABLE TERMINATION

-

-

-

... More
 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of 3.5 core 50 sq mm with factory made clamp noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

20

-

436.98

... More
 Supplying and making end termination with brass compression gland and aluminium lugs for3 1/2 X 50 sq. mm (35mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

2

-

495.21

... More
 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the 4 core 16 sq mm with factory made clamp noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

370

-

262.97

... More
 Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

26

-

356.72

... More
 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the 4 core 10 sq mm with factory made clamp noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

80

-

229.97

... More
 Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

2

-

283.98

... More
 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the 4 core 16 sq mm with factory made clamp sizes using along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

210

-

856.97

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition with 4C 16 sq.mm Ar. Copper Cable terminations

14

-

356.23

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25 Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. with 1C 16 sq.mm Copper Cable YY

910

-

398.68

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. 1C 16 sq.mm Copper Cable termination

66

-

239.2

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. with 1C 10 sq.mm Copper Cable YY

750

-

299.36

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. 1C 10 sq.mm Copper Cable termination

20

-

191.65

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. 1C 6 sq.mm Copper Cable YY

500

-

218.22

... More
 Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition of 1C 6 sq.mm Copper Cable termination

12

-

159.46

... More
CEILING CABLE MANAGEMENT SYSTEM

-

-

-

... More
 Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

20

-

549.77

... More
 Supplying and installing 225 mm width X 50 mm depth X 1.6 mm thickness of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

55

-

643.49

... More
 Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

60

-

735.82

... More
 Supplying and installing 450 mm width X50 mm depth X 2.0 mm thickness of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

40

-

1093.94

... More
 Supply and Installation of GI cable ladder trays of 150X50mm sizeCable Tray with bolt nut fastener including tees, right angle bends, etc., including all fixing accessories etc., as per the site conditions.

105

-

539.68

... More
 Supply and Installation of GI cable ladder trays of 300X50mm size Cable Tray with bolt nut fastener including tees, right angle bends, etc., including all fixing accessories etc., as per the site conditions.

10

-

632.56

... More
EARTHING

-

-

-

... More
 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

12

-

5136.76

... More
 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

230

-

180.46

... More
 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

20

-

976.43

... More
 Supply & Laying of 10 SWG bare Cu. Wire

160

-

192.31

... More
 Supply and Installation of 12 way 25x3mm copper earth bus with all accessories as required.

4

-

479.21

... More
SAFETY EQUIPMENT'S

-

-

-

... More
 supply of 1100 V Rubber mat as per latest IS

2

-

2613.38

... More
 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

1289.26

... More
ASSOCIATED ACCESSORIES

-

-

-

... More
 Supply and Fixing of 25 mm dia MS Conduits

60

-

79.42

... More
 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50

-

78.49

... More
 Supply and laying medium gauge PVC conduit 20 mm of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.

100

-

48.97

... More
 Supply and laying medium gauge PVC conduit 25 mm of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.

200

-

64.36

... More
SHOP DRAWINGS, INSPECTION AND APPROVALS

-

-

-

... More
 Preparation of Shop drawings as per site conditions based the GFC drawings, the same shall be approved by client / consultant / architects. Obtaining approval from Statutory Authorities, Preparation of statutory drawings, completion Report, Arranging for Inspection, attending defects report and obtaining safety certificate from Safety Authorities for commissioning of the electrical system.(including all required statutory Norms ). Five sets as built drawings with soft copy shall be submitted Note:Statutory fees shall be paid by client

2

-

52267.5

... More
NETWORKING

-

-

-

... More
 Supply , installation, testing and commissioning of 4-port British-style face plate

26

-

81.31

... More
 Supply , installation, testing and commissioning of 2-port British -style face plate

296

-

75.5

... More
 Supply , installation, testing and commissioning of 1-port British -style face plate

50

-

69.69

... More
 Supply , installation, testing and commissioning of PVC Back Box

80

-

58.08

... More
 Supply , installation, testing and commissioning of Cat 6 UTP Jack with Strain relief and bend limiting boot - (Yellow for data & Blue for voice)

746

-

297.85

... More
 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required (cost for one run)

33000

-

47.56

... More
 Supply , installation, testing and commissioning of 24-port unloaded, Angled Jack Panel, SL -Series, 1U (for both voice & data)

30

-

3634.12

... More
 Supply , installation, testing and commissioning of Cat 6 7 feet patch cord at both end 100% yellow(for both voice & data)

1005

-

197.45

... More
 Supply , installation, testing and commissioning of 42 U Open Rack with Vertical HDCM , check nut , ladder set , PDU 2 nos etc

3

-

69690

... More
 Supply and installation of 25 mm dia. Metallic Flexible Hose.

100

-

61.07

... More
 Supply and installation of 50 mm dia. Metallic Flexible Hose

100

-

147.02

... More
 Supply and installation of 20 mm dia. Rigid PVC Flexible Hose.

100

-

54.1

... More
 Supply and installation o 25 mm dia. Rigid PVC Flexible Hose.

100

-

58.75

... More
FIRE DETECTION SYSTEM

-

-

-

... More
 INTELLIGENT FIRE ALARM SYSTEM- Analogue Addressable Intelligent 1 loop Fire alarm control panel, provision to make with a minimum capacity of 125 devices + 125 modules per loop, with battery back up for 6 Hrs during normal operation and 15 minutes alarm operation, with minimum 160 Character LCD display, necessary interface card to connect a repeater panel and all hardware & software as per specification.

2

-

128698.98

... More
 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.

4

-

3130.88

... More
 Supplying, installation, testing & commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required.

136

-

267.34

... More
 Supplying, installation, testing & commissioning of fault isolator complete with base as required.

10

-

3587.31

... More
 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. (ABOVE FALSE CEILING & FALSE FLOOR)

88

-

2985.4

... More
 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.- (BELOW FALSE CEILING)

80

-

447.38

... More
 Supplying, installation, testing & commissioning of addressable fire control module complete as required..(ACS TRIP#4, HOOTER#2, BB INTEGRATION#2,PA INTEGRATION#2)

10

-

3291.93

... More
 Supplying, installation, testing & commissioning of intelligent addressable Duct detector including suitable Photo detector complete with base as required.

4

-

8618.49

... More
 Supplying, installation, testing & commissioning of addressable Manual call point complete as required

5

-

4253.31

... More
 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required

5

-

3849.26

... More
 Analogue Addressable Monitor module operating at 24V DC, 2A, rated at 230V, provided with DPDT contact. (BB INTEGRATION#2,PA INTEGRATION#2,SPARE#2)

6

-

2491.61

... More
 Analogue Addressable Control relay module operating at 24V DC, 2A, rated at 230V, provided with DPDT contact.(AC UNITS SERVER#4,AHU#4,UPS/BATTERY#4)

12

-

2800.57

... More
 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

2900

-

146.04

... More
 Supplying and fixing of 25mm medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.

25

-

96.52

... More
 Supply and laying of MS Powder coated Trunking 300 x 50 mm x 2mm with cover & fixing,supports etc as required (Cable dressing for Fire panel )

10

-

873.37

... More
 SITC of PSU for hooters & AHU tripping (inclusive of Battery ckt & battery)

2

-

5011.18

... More
FIRE EXTINGUISHER SYSTEM

-

-

-

... More
 Supply and installation of CO2 type Fire Extinguisher ISI marked confirming to IS:15683. Capacity 4.5 Kg. Complete with delivery hose horn, squeeze grip release valve, locking arrangement,operating temperature -30°C to +55°C, supplied with body bearing IS 7285 mark and approved by CCoE tested at 250 kgf/cm2., fitted with ISI marked & CCoE approved valve as per IS 3224. CO2 Gas as per IS: 15222. externally painted with PO Red Shade No. 538 of IS 5, operation manual and floor stand or Wall Mount Bracket including accessories as required as per site condition

3

-

3903.28

... More
 Supply and installation of Powder Fire Extinguisher (Stored Pressure type) (Powder pressurized with dry nitrogen gas at 15 bar.) capacity: 6kg duly ISI marked conforming to IS: 15683:2006, with IS 14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual,Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, and floor stand or Wall Mount Bracket including accessories as required as per site condition

10

-

2402.19

... More
Supply and installation of FE36 Automatic wall Mounted Clean agent Extinguisher - 5 Kg with Wall mounting accessories including nozzle(57deg), pressure guage. ISI approved

4

-

23495.03

... More
 SIGNAGE'S SYSTEM

-

-

-

... More
SITC of recess mounting type emergency SIGNAGE system “FIRE EXIT” as per IS 9583-1981 LED configured with single LED 8 watts suitable for 230v, 50Hz that can provide continuous illumination through mains power supply and with rechargeable battery backup of 90 minutes single side of size 400 x 150 mm (Similar to Prolite PEL LED E/M/P (RM) or equivalent)

4

-

3101.65

... More
SITC of recess mounting type emergency SIGNAGE system “EMERGENCY EXIT” as per IS 9583-1981 LED configured with single LED 8 watts suitable for 230v, 50Hz that can provide continuous illumination through mains power supply and with rechargeable battery backup of 90 minutes double side of size 400 x 150 mm (Similar to Prolite PEL LED E/M/P (RM) or equivalent)

30

-

3217.8

... More
SITC of SIGNAGE system “EXTINGUISHER” as per IS 9583-1981 Photoluminescent & maintained type Autoglow, with suspension chains double side of size 300 x 150 mm (Similar to Prolite PEL LED E/M/P (RM) or equivalent)

10

-

430.2

... More
SITC of SIGNAGE system "MCP" as per IS 9583-1981 Photoluminescent & maintained type Autoglow, with suspension chains double side of size 300 x 150 mm (Similar to Prolite PEL LED E/M/P (RM) or equivalent)

6

-

430.2

... More
SITC of SIGNAGE system "EVACUATION PLAN"-Autoglow Fire escape route map in clear acrylic glass and required glass studs supports etc. Indicating direction, Key plan, contact numbers etc. (The sample of the same need to be presented for approval before execution)…. (Maximum size of the board A3) with necessary wall mount supports" as per IS 9583-1981

6

-

3333.95

... More
 Supply, Installation, Testing and Commissioning of Master Console panel including support bracket (12 TRANSDUCER PER CONSOLE)

3

-

16075.65

... More
 SITC of Transducer capable of Emitting Ultrasonic sound of frequencies 20 Khz and higher, with blinking LED Indication & shall capable to covering area of 150 Sq ft in floor & ceiling void and 300 sqft in Room void.

24

-

4130.8

... More
 SITC of 1 pair flexible 14/40 SWG Specially coated wire, PVC sheathed Cable

180

-

49.46

... More
 Supply and surface laying of 25mm dia 2mm thick PVC FRLS Conduit with GI Saddels and spacers at every 0.3 meter

140

-

96.66

-

-

-

... More
 Supply, installation, testing, and commissioning of 11.0 TR, 4400CFM nominal capacity ductable split air conditioners (indoor and outdoor unit)with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, microprocessor control with digital display, R410A/R407C refrigerant gas, vibration isolation pads etc. Including Stand for Out Door Unit.Units should be compatible for BMS integration.

2

-

169288.63

... More
 Supply, installation, testing, and commissioning of 8.5 TR, 3400CFM nominal capacity ductable split air conditioners (indoor and outdoor unit)with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, microprocessor control with digital display, R410A/R407C refrigerant gas, vibration isolation pads etc. Including Stand for Out Door Unit.Units should be compatible for BMS integration.

3

-

147742.8

... More
 Supply, installation, testing, and commissioning of 5.5 TR, 2200CFM nominal capacity ductable split air conditioners (indoor and outdoor unit)with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, microprocessor control with digital display, R410A/R407C refrigerant gas, vibration isolation pads etc. Including Stand for Out Door Unit.Units should be compatible for BMS integration.

1

-

104651.15

... More
 Supply, installation, testing, and commissioning of 3.0 TR, 1200CFM nominal capacity ductable split air conditioners (indoor and outdoor unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, microprocessor control with digital display, R410A/R407C refrigerant gas, vibration isolation pads etc. Including Stand for Out Door Unit.Units should be compatible for BMS integration.

4

-

92339.25

... More
 Supply & laying of 28.6 mm ,18 SWG Hard drawn Refrigerant copper pipe with 13 mm thick Class O' Nitrile rubber insulation between indoor & outdoor units for the above DX units including pressure testing and Supports,clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition,etc.

140

-

850.23

... More
 Supply & laying of 22.2 mm, 18 SWG Hard drawn Refrigerant copper pipe with 13 mm thick Class O' Nitrile rubber insulation between indoor & outdoor units for the above DX units including pressure testing and Supports,clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition,etc.

170

-

644.41

... More
 Supply & laying of 15.9 mm 18 SWG Hard drawn Refrigerant copper pipe with 13 mm thick Class O' Nitrile rubber insulation between indoor & outdoor units for the above DX units including pressure testing and Supports,clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition,etc.

110

-

478.58

... More
 Supply & laying of 9.5 mm18 SWG Hard drawn Refrigerant copper pipe with 13 mm thick Class O' Nitrile rubber insulation between indoor & outdoor units for the above DX units including pressure testing and Supports,clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition,etc.

80

-

371.97

... More
 Supply, Installation, Testing & Commissioning of factory made 2.0 TR Hi wall mounted minimum 3 star rating R410A gas Type Air conditioner units complete with centrifugal blower cooling coil etc., enclosed the insulation along with matching air cooled condenser with Rotary compressor all in with microprocessor control & Remote Control, Stabilizer including gas charging, Supports for outdoor units, Safety controls, etc. Including Stand for Out Door.Units should be compatible for BMS integration.including Minor civil works required if any.

8

-

51065.75

... More
 Supply & laying of Soft drawn Refrigerant copper piping with 13 mm Thick Class O' Nitrile rubber insulation between indoor & outdoor units including pressure testing and civil works,slotted angles,Supports,clamps, etc.with 15.9 mm size

120

-

502.27

... More
 Supply & laying of Soft drawn Refrigerant copper piping with 13 mm Thick Class O' Nitrile rubber insulation between indoor & outdoor units including pressure testing and civil works,slotted angles,Supports,clamps, etc. with 9.5 mm size

120

-

336.44

... More
 Supply & laying of 4C x 10 sq.mm Copper Armoured Power cabling between isolator to Outdoor unit.

30

-

480.71

... More
 Supply & laying of 7C x 2.5 sq.mm Copper Control cabling between indoor to Outdoor unit.

300

-

242.6

... More
 Supply & laying of 4C x 2.5 sq.mm copper Flexible Power cabling between breaker to outdoor unit and outdoor to indoor unit.

180

-

155.26

... More
 Supply, installations testing & commissioning of Auto sequential controllers for above units controlling of 2 units Ac units.

4

-

8205.32

... More
 Supply and laying of high density PVC drain pipe with 9 mm Thick Nitrile rubber insulation with size of 25 mm dia

100

-

159.14

... More
 Supply and laying of high density PVC drain pipe with 9 mm Thick Nitrile rubber insulation with 32 mm dia

100

-

178.77

... More
 Supply and laying of high density PVC drain pipe with 9mm Thick Nitrile rubber insulation with 40 mm dia

100

-

196.89

... More
 Supply & installation ,testing & commissioning of Drain pumps with all necessary equipment

6

-

4454.41

... More
 Supply and erections of 300 X50 mm width 16G G.I Cable tray with Elbow,T-Joints,and all accessories.

100

-

387.79

... More
Supply, installation, balancing and commissioning of factory fabricated 24G GSS sheet metal rectangular ducting as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications complete as required. Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material along with mill test certificates, Ductmate (TDF) Flanges for all sizes of the duct. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative, shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with SMACNA standards. The Duct shall be supported with specified supports at regular intervals. The sheet metal ducting running inside AHU Rooms & near AHU rooms should be supported with special acoustic hangers to avoid transmission of vibration from AHU Room to adjacent sensitive areas. The insulation executed on the ducts inside the AHU Room shall be further finished with fiber glass cloth for mechanical protection. To ensure the air tightness, all ducts shall be checked with Smoke Test after completion of installation but before applying insulation including Air balancing using Hood machine Pressure 500 Pa

570

-

707.95

... More
Supply, installation, balancing and commissioning of factory fabricated 22 G GSS sheet metal rectangular ducting as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications complete as required. Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material along with mill test certificates, Ductmate (TDF) Flanges for all sizes of the duct. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative, shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with SMACNA standards. The Duct shall be supported with specified supports at regular intervals. The sheet metal ducting running inside AHU Rooms & near AHU rooms should be supported with special acoustic hangers to avoid transmission of vibration from AHU Room to adjacent sensitive areas. The insulation executed on the ducts inside the AHU Room shall be further finished with fiber glass cloth for mechanical protection. To ensure the air tightness, all ducts shall be checked with Smoke Test after completion of installation but before applying insulation including Air balancing using Hood machine Pressure 500 Pa

160

-

993.07

... More
Supply, installation, balancing and commissioning of factory fabricated 20 G GSS sheet metal rectangular ducting as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications complete as required. Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material along with mill test certificates, Ductmate (TDF) Flanges for all sizes of the duct. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative, shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with SMACNA standards. The Duct shall be supported with specified supports at regular intervals. The sheet metal ducting running inside AHU Rooms & near AHU rooms should be supported with special acoustic hangers to avoid transmission of vibration from AHU Room to adjacent sensitive areas. The insulation executed on the ducts inside the AHU Room shall be further finished with fiber glass cloth for mechanical protection. To ensure the air tightness, all ducts shall be checked with Smoke Test after completion of installation but before applying insulation including Air balancing using Hood machine Pressure 500 Pa

90

-

1213.07

... More
Supply, installation, balancing and commissioning of factory fabricated 18 G GSS sheet metal rectangular ducting as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications complete as required. Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material along with mill test certificates, Ductmate (TDF) Flanges for all sizes of the duct. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative, shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with SMACNA standards. The Duct shall be supported with specified supports at regular intervals. The sheet metal ducting running inside AHU Rooms & near AHU rooms should be supported with special acoustic hangers to avoid transmission of vibration from AHU Room to adjacent sensitive areas. The insulation executed on the ducts inside the AHU Room shall be further finished with fiber glass cloth for mechanical protection. To ensure the air tightness, all ducts shall be checked with Smoke Test after completion of installation but before applying insulation including Air balancing using Hood machine Pressure 500 Pa

30

-

1355.56

... More
Supply, fixing, testing and commissioning of Cross Talk silencer of Size: 300X300mm Z- type fabricated using 22G GI Sheets with internal 10 mm thick Armasound insulation class 1 rating Open cell nitrile rubber with density of 140 - 180 kg / m³. with necessary fixing arrangements, anchor bolts, full thread rods, angle supports etc, as scheduled and as specified. (area calculation : ((W+H)x2)xL)

26

-

2482.99

... More
 Supply, fixing, testing and commissioning of Cross Talk silencer Size: 200X200mm Z-type fabricated using 22G GI Sheets with internal 10mm thick Armasound insulation class 1 rating Open cell nitrile rubber with density of 140 - 180 kg / m³. with necessary fixing arrangeemnts, anchor bolts, full thread rods, angle supports etc, as scheduled and as specified. (area calculation : ((W+H)x2)xL)

4

-

2196.88

... More
 Supplying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

16

-

9976.95

... More
 Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

14

-

5674.8

... More
 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

10

-

12138.76

... More
 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

10

-

7848.82

... More
 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

10

-

7642.29

... More
 Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room

1.5

-

8822.3

... More
 Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room Motorized (ON-OFF Type) duct mounted Gl volume control Actuator

4

-

7667.05

... More
 Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damber

6

-

9936.33

... More
 Fusible link fire dampers for fire partitions(where ever HVAC ducts crossing fire partitions & critical rooms)

1.2

-

10559.68

... More
 Supply & installation of Actuators with Control Panel for above fire dampers- HIGH TORQUE TYPE

5

-

9841.54

... More
 Supply & Lying of 3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit for panel to Fire dampers inside floor

70

-

252.21

... More
 Supply & installation of Fire Return Canvas for CSU's, AHUs, etc

5

-

873.46

... More
 Supply and installation of 10 mm Thick (Accoustic) Duct liner (Insulation) of specified thickness of Elastromeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permanence of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used.

130

-

882.51

... More
 Supply and installation 9mm Thick Thermal (Insulation) of specified thickness of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-

750

-

371.91

... More
 Supply and installation Under deck Insulation 16 mm thickness of Elastromeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permance of 0.10. Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material

1001

-

671.89

... More
 Supply ,Installation & Commissioning of Centrifugal Inline Toilet Exhaust air fan - 700CFM with Static Pressure - 15mm

5

-

12914.5

... More
 Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15 mm for following fan capacity. - Closed cabins Fresh air fan with prefilter - 1500 CFM

3

-

34741.5

... More
 Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15 mm for following fan capacity. - Electrical room Exhaust air fan - 500 CFM

2

-

10361.5

... More
 Supply ,Installation & Commissioning of Centrifugal Inline Exhaust fan with Static Pressure - 15 mm for following fan capacity. - Cafeteria exhaust - 300 CFM

2

-

9142.5

... More
 Supply and installations of door louver for toilet fresh air

4

-

5506.99

... More
 Supply and installations of disc valve with collar damper

50

-

750

... More
 Chipping, chasing & Plastering the wall openings in cement mortar 1:6 of 15 mm thick finishing to line and level with sand faced finishing. Including all leads & curing etc

2

-

4999.91

... More
 Supply & INSTALLATION OF VARIABLE AIR VOLUME BOXES (Damper Actuator Type) 200-500 cfm - Variable Air Volume (VAV) Units are fabricated out of heavy gauge steel, mechanically sealed with gasket & leak resistance construction. Both supply & discharge shall be suitable for duct connections. Boxes shall be of variable air volume at the inlet and variable at outlet and shall be fitted with air volume regulator of the fully proportional type. The boxes shall be supplied with all internal attenuation treatment and acoustical damped casing necessary to achieve the required noise criteria. Casing shall be 20 BG minimum fitted with a completely sealed, easily removable means of access to all internal parts. Access to all boxes must be from the underside only. Maximum allowable static pressure to the boxes for its satisfactory operation shall not exceed 0.20” WG. Boxes shall be able to reset any air flow between zero and the maximum air quantity that the boxes can handle without changing orifices or other parts. Air quantity limiters will not be accepted. A suitable device shall be provided for the field adjustment of minimum air flow. All boxes shall be intially factory set at minimum air quantity of 50% of the design requirements. Under shut-off conditions, all boxes shall not have air leakage more than 20% of the maximum air quantity. VAV Unit shall be ceiling suspended with hanger brackets & vibration isolators. All accessories listed under specifications should be considered for pricing VAVs. Direct Output temperature sensor comprising of high quality thermistor or platinum sensing element should be supplied with VAVs. The look of the sensor should be rectangular in shape as shown in our schedule drawings showing vav box quantities. Projection of the sensor should not exceed 27 mm . Necessary Hardware/ software for integrating the VAV Boxes to the third party system which shall be capable of transferring 4 points as specified in the technical specification for the quantity indicated below shall also be considered in the scope. VAV Plug top & power cablie from VAV to plug top is part of HVAC/VAV vendor scope.

5

-

20113.5

... More
Supply & INSTALLATION OF VARIABLE AIR VOLUME BOXES (Damper Actuator Type)  300-1000 cfm - Variable Air Volume (VAV) Units are fabricated out of heavy gauge steel, mechanically sealed with gasket & leak resistance construction. Both supply & discharge shall be suitable for duct connections. Boxes shall be of variable air volume at the inlet and variable at outlet and shall be fitted with air volume regulator of the fully proportional type. The boxes shall be supplied with all internal attenuation treatment and acoustical damped casing necessary to achieve the required noise criteria. Casing shall be 20 BG minimum fitted with a completely sealed, easily removable means of access to all internal parts. Access to all boxes must be from the underside only. Maximum allowable static pressure to the boxes for its satisfactory operation shall not exceed 0.20” WG. Boxes shall be able to reset any air flow between zero and the maximum air quantity that the boxes can handle without changing orifices or other parts. Air quantity limiters will not be accepted. A suitable device shall be provided for the field adjustment of minimum air flow. All boxes shall be intially factory set at minimum air quantity of 50% of the design requirements. Under shut-off conditions, all boxes shall not have air leakage more than 20% of the maximum air quantity. VAV Unit shall be ceiling suspended with hanger brackets & vibration isolators. All accessories listed under specifications should be considered for pricing VAVs. Direct Output temperature sensor comprising of high quality thermistor or platinum sensing element should be supplied with VAVs. The look of the sensor should be rectangular in shape as shown in our schedule drawings showing vav box quantities. Projection of the sensor should not exceed 27 mm . Necessary Hardware/ software for integrating the VAV Boxes to the third party system which shall be capable of transferring 4 points as specified in the technical specification for the quantity indicated below shall also be considered in the scope. VAV Plug top & power cablie from VAV to plug top is part of HVAC/VAV vendor scope.

2

-

21332.5

... More
Supply & INSTALLATION OF VARIABLE AIR VOLUME BOXES (Damper Actuator Type)  800-1600 CFM - Variable Air Volume (VAV) Units are fabricated out of heavy gauge steel, mechanically sealed with gasket & leak resistance construction. Both supply & discharge shall be suitable for duct connections. Boxes shall be of variable air volume at the inlet and variable at outlet and shall be fitted with air volume regulator of the fully proportional type. The boxes shall be supplied with all internal attenuation treatment and acoustical damped casing necessary to achieve the required noise criteria. Casing shall be 20 BG minimum fitted with a completely sealed, easily removable means of access to all internal parts. Access to all boxes must be from the underside only. Maximum allowable static pressure to the boxes for its satisfactory operation shall not exceed 0.20” WG. Boxes shall be able to reset any air flow between zero and the maximum air quantity that the boxes can handle without changing orifices or other parts. Air quantity limiters will not be accepted. A suitable device shall be provided for the field adjustment of minimum air flow. All boxes shall be intially factory set at minimum air quantity of 50% of the design requirements. Under shut-off conditions, all boxes shall not have air leakage more than 20% of the maximum air quantity. VAV Unit shall be ceiling suspended with hanger brackets & vibration isolators. All accessories listed under specifications should be considered for pricing VAVs. Direct Output temperature sensor comprising of high quality thermistor or platinum sensing element should be supplied with VAVs. The look of the sensor should be rectangular in shape as shown in our schedule drawings showing vav box quantities. Projection of the sensor should not exceed 27 mm . Necessary Hardware/ software for integrating the VAV Boxes to the third party system which shall be capable of transferring 4 points as specified in the technical specification for the quantity indicated below shall also be considered in the scope. VAV Plug top & power cablie from VAV to plug top is part of HVAC/VAV vendor scope.

3

-

23770.5

... More
 Supply and installation of 2C, 1.5 Sq mm, screened ATC cable communication cable in PVC Conduit of 19 mm dia for looping between VAV’S & BMS.

250

-

40.99



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.