Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Civil And Construction
Building Construction
Eprocure
Opening Date25 Jan 2023
Closing DateCancelled
Tender Amount₹ 19,58,89,110 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.12.6.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3.5 core 95 sq.mm

150

-

-

... More
90.12.6.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3.5 core 185 sq.mm

150

-

-

... More
90.12.6.35 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3.5 core 240 sq.mm

60

-

-

... More
90.12.6.36 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3.5 core 300 sq.mm

300

-

-

... More
4.6.11 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness

300

-

-

... More
90.12.40.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4 core 6 sq.mm

1180

-

-

... More
90.12.40.35 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4core 25 sq.mm

120

-

-

... More
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres

750

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

750

-

-

... More
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness

350

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

500

-

-

... More
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness

250

-

-

... More
1.21.5 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm

2000

-

-

... More
od291200/2022_2023 : Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification and SLD enclosed chiller panel Incoming , 630A 35KA 4P ATS- 1 No, 630A 35KA, 4P MCCB - with all connected accessories – 1Nos. Instruments compartment. Multi function meter(Having the parameters of Ammeter,Voltmeter and KWH meter,kW,KVA,Hz,PF.), Metering.CTs, R,Y,B and On/Off / Trip indication lamp with MCB, selector switch, push botton etc., Outgoing-250 A TPN 25 KA MCCB- 4 Nos,Outgoing-100 A TPN 25 KA MCCB- 9 Nos With necessary aluminium busbars, interconnections, neutral link, suitable aluminium busbar for cable termination, door interlock and all other necessary accessories etc, all meters should have RS 485 port,All the RS-485 port of the meter connected together through single cable and terminated with terminal block in the common cable chamber for easy termination 630 Amps TPN Aluminum busbars:- All the neutral busbars shall have half the capacity of phase busbars.

1

-

-

... More
od291201/2022_2023 : Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification and SLD enclosed AHU panel Incoming , 400A 35KA 4P ATS- 1 No, 400A 35KA, 4P MCCB - with all connected accessories – 1Nos. Instruments compartment. Multi function meter(Having the parameters of Ammeter,Voltmeter and KWH meter,kW,KVA,Hz,PF.), Metering.CTs, R,Y,B and On/Off / Trip indication lamp with MCB, etc., Outgoing-250 A TPN 25 KA MCCB- 1 Nos,Outgoing-125 A TPN 25 KA MCCB- 2 Nos,Outgoing-80 A TPN 25 KA MCCB- 2 Nos ,Outgoing-63 A TPN 25 KA MCCB- 2 Nos With necessary aluminium busbars, interconnections, neutral link, suitable aluminium busbar for cable termination, door interlock and all other necessary accessories etc, all meters should have RS 485 port, All the RS-485 port of the meter connected together through single cable and terminated with terminal block in the common cable chamber for easy termination 400 Amps TPN Aluminum busbars:- All the neutral busbars shall have half the capacity of phase busbars.<br>

1

-

-

... More
90.12.6.37 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 3.5 core 400 sq.mm

300

-

-

... More
od291728/2022_2023 : Supply and laying of 1Cx70 sq.mm CU HFFR flexible cable

400

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

12

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

8

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

6

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

6

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

12

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

16

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

16

-

-

... More
90.12.24.9 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 70 sq.mm

110

-

-

... More
90.16.4.5 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm GI strip

100

-

-

... More
90.16.4.6 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run). 40x6 mm GI strip

200

-

-

... More
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25X 3 mm Copper strip

200

-

-

... More
90.16.4.9 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run). 25 X 6 mm Copper strip

300

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10SWG)

100

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 4 ( 8 SWG)

300

-

-

... More
1.7.1 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

2000

-

-

... More
1.7.2 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire

100

-

-

... More
1.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire

1000

-

-

... More
1.7.4 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire

200

-

-

... More
1.54.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

200

-

-

... More
1.3.1 : Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

50

-

-

... More
90.12.40.33 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4C X 10 sq.mm

730

-

-

... More
90.12.40.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4C X 16 sq.mm

450

-

-

... More
od293069/2022_2023 : Supply, installation, testing and commissioning of Lead Acid, sealed, free maintenance VRLA Battery with unit capacity of 12 V, 100 AH x 100 nos for 2 frame (50 each) with 180000 VAH with dual string; Nominal UPS Battery Voltage +/-300 Volt DC (50 blocs x 2), configurable from +/-264 to +/-312 VDC (44-52 blocs), Battery charger with Smart charge technology. 3-stage advanced charging cycle Intelligent with boost charge and advanced management having Max Charging Current 5 A each power module and independent battery configuration (max) 5 set (one for each power module installed) etc complete at site and as per directions of Engineer-in-charge

1

-

-

... More
od293191/2022_2023 : Flame proof Stainless Steel Clean Room Sockets, 25 A, 3 Phase Industrial Sockets

5

-

-

... More
od293192/2022_2023 : Clean Room modular Switch/Sockets: Supply, installation, testing and commissioning of Single Phase, 15 A, 2 Module , GI box along with modular base and cover plate, modular switches/sockets in recess/wall/wall panel etc. as required

75

-

-

... More
2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.17 : Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

20

-

-

... More
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
od293216/2022_2023 : Control Cables: Supply and installation different size of<br>Instrumentation cables conforming to BS 5308, type II, 300/500 V grade with stranded ( copper conductor, PVC insulated. 4C X 1.5 sq.mm Cu armoured cable

2100

-

-

... More
od293217/2022_2023 : Control Cables: Supply and installation different size of<br>Instrumentation cables conforming to BS 5308, type II, 300/500 V grade with stranded ( copper conductor, PVC insulated. 3C X 1.5 sq.mm Cu armoured cable

1900

-

-

... More
od293218/2022_2023 : Supply, installation, testing and commissioning of 4Cx2.5 Cu armoured cable of 1.1 KV grade in existing open trench/ tray

300

-

-

... More
od293219/2022_2023 : Supply, installation, testing and commissioning of 4Cx4 Cu armoured cable of 1.1 KV grade in existing open trench/ tray.

800

-

-

... More
od293220/2022_2023 : Design, supply, erection of “ASHLOK” safe earthing elecrode Type-19 (Special), burried in ground, The chamber should be provided with 600mm x 600mm Heavy duty CI Chequered Plate cover with hinge and Stainless steel bolt nuts. The Cover should be painted at site with Black and then Green colour.

10

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
1.20.2 : Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
od294586/2022_2023 : Supply and connecting indoor type cable end joints for the following size copper conductor by employing necessary brass double compression gland and Cu lugs for Power cable of different size 16 sq.mm x 4 core - copper

58

-

-

... More
od294587/2022_2023 : Supply and connecting indoor type cable end joints for the following size copper conductor by employing necessary brass double compression gland and Cu lugs for Power cable of different size 10 sq.mm x 4 core - copper

30

-

-

... More
od294588/2022_2023 : Supply and connecting indoor type cable end joints for the following size copper conductor by employing necessary brass double compression gland and Cu lugs for Power cable of different size 4core x 25sq. mm

25

-

-

... More
od295149/2022_2023 : Supply and connecting indoor type cable end end joints for control cables of size 1.5 sq.mm x 4 core copper armoured.

132

-

-

... More
od295150/2022_2023 : Supply and connecting indoor type cable end end joints for control cables of size 1.5sq.mm x 3 core copper armoured.

186

-

-

... More
od295151/2022_2023 : Supply and connecting indoor type cable end joints for the following size copper conductor by employing necessary brass double compression gland and Cu lugs for Power cable of different size 4 sq.mm x 4 core - copper.

12

-

-

... More
od295152/2022_2023 : Supply and connecting indoor type cable end joints for the following size copper conductor by employing necessary brass double compression gland and Cu lugs for Power cable of different size 6 sq.mm x 4 core - copper.

16

-

-

... More
od296806/2022_2023 : Preparation of necessary drawing (Initial & final) and getting all necessary approvals/sanction, inspection etc.from EB and Electrical Inspectorate including all sundries expenses except statutory charges. Statutory charges shall be reimbursed only after producing valid proof.

1

-

-

... More
od311054/2022_2023 : Supply, Installation, testing and commissioning of outdoor type isolation panel with stand for chiller,415V,50Hz, 250A 25KA, TPN MCCB with all connected accessories. Instruments compartment. Multi function meter(Having the parameters of Ammeter,Voltmeter and KWH meter,kW,KVA,Hz,PF.), Metering.CTs, R,Y,B and On/Off / Trip indication lamp with MCB. All meters should have RS 485 port

3

-

-

... More
od311056/2022_2023 : Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification and SLD enclosed UPS panel Incoming, 415V,50Hz, 250A 35KA, 4P MCCB with all connected accessories – 1Nos. Instruments compartment. Multi function meter(Having the parameters of Ammeter,Voltmeter and KWH meter,kW,KVA,Hz,PF.), Metering.CTs, R,Y,B and On/Off / Trip indication lamp with MCB etc., Outgoing-200 A TPN 25 KA MCCB- 2 Nos With necessary aluminium busbars, interconnections, neutral link, suitable aluminium busbar for cable termination, door interlock and all other necessary accessories etc, All meters should have RS 485 port, All the RS-485 port of the meter connected together through single cable and terminated with terminal block in the common cable chamber for easy termination 250 Amps TPN Aluminium busbars:- All the neutral busbars shall have double the capacity of phase busbars.

1

-

-

... More
od311057/2022_2023 : Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification and SLD enclosed UPS panel Incoming,415V,50HZ, 250A 35KA, 4P MCCB with all connected accessories – 1Nos. Instruments compartment. Multi function meter(Having the parameters of Ammeter,Voltmeter and KWH meter,kW,KVA,Hz,PF.), Metering.CTs, R,Y,B and On/Off / Trip indication lamp with MCB etc., Outgoing-160 A TPN 25 KA MCCB- 1 Nos,Outgoing-125 A TPN 25 KA MCCB- 4 Nos,Outgoing-63 A TPN 16 KA MCCB- 2 Nos. With necessary aluminium busbars, interconnections, neutral link, suitable aluminium busbar for cable termination, door interlock and all other necessary accessories etc,All meters should have Rs 485 port, All the RS-485 port of the meter connected together through single cable and terminated with terminal block in the common cable chamber for easy termination. 250 Amps TPN Aluminum busbars:- All the neutral busbars shall have double the capacity of phase busbars.

1

-

-

... More
od311058/2022_2023 : Supply, installation, and commissioning of MODUALAR UPS 2x125KW FRAME With 25kw min. 3 nos modules in each frame of 3 pahse modules three phase in and out with built in PRS configurations. with indoor (IP20) with surge protection system with 20 min backup battery @ 150 kW load Minumum VAH 120000 with seperate battery bank with MCCB suitable for battery bank for each bank, Input pf 0.99, Input THDi less than 3%, double conversion technology with input 415V, 50Hz three phase, output 415V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic/ noise at 1m of the system should be less than 80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard along with PEP (LEED) certificates. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. UPS 2 X 125Kw (75Kw) shall be connected through parallel and single out put to be provided with isolator.

1

-

-

... More
od311917/2022_2023 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. Group C

200

-

-

... More
od312228/2022_2023 : Clean room Light Fixture: Supply, Installation, testing & commissioning, 240 V, single phase 40 watt recessed type LED light fixture diffuser for general/passage area /utility area room lighting size: 2 feet x 2 feet . Light fixture shall include fixing the same on ceiling grid, complete with cool day light. Reference model No: LCBOR-40-CDL ( Crompton) or equivalent as per approved make

50

-

-

... More
od312229/2022_2023 : Clean room Light Fixture: Supply, Installation, testing and commissioning , 240 V, single phase , 40 watt recessed type LED light fixture diffuser for clean room lighting size: 4 feet x 2 feet . Light fixture shall include fixing the same on ceiling, complete with cool day light. Reference model No: FP-PL - 2X4- 40W ( Metalux) or equivalent as per approved make

170

-

-

... More
od312230/2022_2023 : Clean room Light Fixture: Supply, Installation, testing and commissioning of LED grid Tear drop, 240 V, single phase 40 watt, 3000K light fixture with diffuser for clean room lighting. Ref model No:CR388C LED40 CW L120PSU (Philips) or equivalent as per approved make

45

-

-

... More
od312595/2022_2023 : Supplying and fixing 63A rating, 415 V, 10 kA, D curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

5

-

-

... More
od312596/2022_2023 : Supplying and fixing 63A rating, 415 V, 10 kA, D curve, miniature circuit breaker suitable for inductive load of triple poles and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.

4

-

-

... More
od312597/2022_2023 : Supplying and fixing 40A rating, 415 V, 10 kA, D curve, miniature circuit breaker suitable for inductive load of triple poles and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
od312598/2022_2023 : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, D curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

8

-

-

... More
od312599/2022_2023 : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, D curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

84

-

-

... More
2.4.4 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4+12), Double door,IP 43

1

-

-

... More
2.4.5 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4+18), Double door, IP 43

3

-

-

... More
2.5.6 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door, IP 43

4

-

-

... More
od312819/2022_2023 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, 40 A, residual current circuit breaker (RCCB) having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

9

-

-

... More
od313097/2022_2023 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCB's (but without MCCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)6 way (4 + 18), Double door, IP 43

1

-

-

... More
od313098/2022_2023 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCB s (but without MCCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door

1

-

-

... More
90.12.6.42 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4C X 25 sq.mm

240

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

12

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 3.15 mm copper conductor ( 10 SWG)

200

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4 mm copper conductor ( 8 SWG)

300

-

-

... More
od325109/2022_2023 : Providing and fixing of 415V, 125A TPN MCCB, 25KA with thermomagnetic release and terminal spreaders in existing DB, making connections, etc. as required, In 80 to 100%, Fixed magnetic

2

-

-

... More
od325110/2022_2023 : Providing and fixing of 415V, 160A TPN MCCB, 25KA with thermomagnetic release and terminal spreaders in existing DB, making connections, etc. as required, In 80 to 100%, Fixed magnetic.

1

-

-

... More
od325111/2022_2023 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCBO), having a sensitivity current 100 mA as required. 40A

3

-

-

... More
HVAC

-

-

-

... More
od293239/2022_2023 : supply, installation, testing and commissioning Manual Flow Balancing cum Flow measurement valve in the outlet line of the AHU and MAU

10

-

-

... More
od293240/2022_2023 : Supply, installation, testing and commissioning of Motorized three-way flow control in the return line of the AHU with bms communication port.

5

-

-

... More
od293241/2022_2023 : Supply, installation, testing and commissioning of Desiccant Type Dehumidifier: capacity 4000 CFM.

1

-

-

... More
od293242/2022_2023 : Supply, installation, testing and commissioning of Stainless steel Pan humidifier kit of adequate capacity for MAU.

1

-

-

... More
od293243/2022_2023 : Supply,installation,testing and commissioning of Electrical strip heater mounted inside the AHU. AHU 4: 15.0 KW

1

-

-

... More
od293244/2022_2023 : Supply,installation,testing and commissioning of Electrical strip heater mounted inside the AHU. AHU3: 15.0 KW

1

-

-

... More
od293245/2022_2023 : Supply,installation,testing and commissioning of Electrical strip heater mounted inside the AHU. AHU2: 24.0 KW.

1

-

-

... More
od293246/2022_2023 : Supply,installation,testing and commissioning of Electrical strip heater mounted inside the AHU. AHU1: 24.0 KW.

1

-

-

... More
od293247/2022_2023 : Design, supply, installation, Testing and commissioning of Make-up Air Unit (MAU), Capacity - 4000 CFM @ 200 mm swg

1

-

-

... More
od293248/2022_2023 : Design, supply, installation, Testing and commissioning of Air Handling Units (AHUs), with minimum capacity as indicated in the individual AHU. AHU -4 Capacity - 8900 cfm @ 150mm swg

1

-

-

... More
od293249/2022_2023 : Design, supply, installation, Testing and commissioning of Air Handling Units (AHUs), with minimum capacity as indicated in the individual AHU. AHU - 3 Capacity - 9800 cfm @ 150mm swg

1

-

-

... More
od293250/2022_2023 : Design, supply, installation, Testing and commissioning of Air Handling Units (AHUs), with minimum capacity as indicated in the individual AHU.AHU - 2 Capacity - 22800 cfm @ 150mm swg

1

-

-

... More
od293251/2022_2023 : Design, supply, installation, Testing and commissioning of Air Handling Units (AHUs), with minimum capacity as indicated in the individual AHU. AHU -1 Capacity - 17200 cfm @ 150mm swg

1

-

-

... More
od293573/2022_2023 : Supply, loading, unloading, lifting, shifting, installation, testing and commissioning of factory assembled microprocessor controlled air- cooled VFD SCREW chiller -70TR "<br> as per detailed specification attached

3

-

-

... More
od293574/2022_2023 : Supply, installation, testing and commissioning of Air Flow meter for measurement of airflow at the MAU and AHU.

5

-

-

... More
od293575/2022_2023 : Supply, installation, testing and commissioning of Temperature, RH and Dew point meter - Accuracy: Temp. +/- 0.2 Deg C, RH +/-1 %.

1

-

-

... More
od293576/2022_2023 : Supply, installation, testing and commissioning of compatible VFD for fan motors of AHU, MAU and pump

8

-

-

... More
od293577/2022_2023 : Supply, installation, testing and commissioning of Thyristors based control devise for electric heaters.

5

-

-

... More
od293578/2022_2023 : Supply, installation, testing and commissioning of Air stat at the outlet of the AHUs and MAU.

10

-

-

... More
od293579/2022_2023 : Supply, installation, testing and commissioning of Air flow diffusers for supply and return air flow MOC - aluminum<br>construction with complete fittings and accessories.

13.94

-

-

... More
od293580/2022_2023 : "Insulation of duct using Aluminium faced Closed cell Nitrile rubber, Class & O fire rating, 50 mm thick with a density not less than 50 Kg/m3 and as per detailed specification.

1393.55

-

-

... More
od293991/2022_2023 : Supply and fixing of Insulation of duct using Aluminium faced Closed cell Nitrile rubber, Class O fire rating, 19 mm thick with a density not less than 50 Kg/m3 and as per detailed specification.

3251.61

-

-

... More
od294007/2022_2023 : Supply, installation, testing and commissioning of Smoke/fire damper, complete with frame, supports, belimo motor actuators, fire and smoke sensors, controls, limit switch and other standard accessories all complete at the suction of ahus.

5

-

-

... More
od295289/2022_2023 : Supply, installation, testing and commissioning of inverter type 1.5 Tonner Spit AC unit. 5 star rating

4

-

-

... More
od295406/2022_2023 : Supply, installation, testing and commissioning of volume control dampers in the duct with Al moc blades with locking arrangement.

35

-

-

... More
od310822/2022_2023 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006. 1.00mm

936

-

-

... More
od310823/2022_2023 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006. 0.8mm

2788

-

-

... More
od310824/2022_2023 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006. 0.63mm

936

-

-

... More
od312825/2022_2023 : SITC of Horizontal end suction top discharge pumps with minimum capacity of 910 LPM @ 3 kg/cm2 Head, with factory fitted mechanical seal, bronze impeller, EN8/SS shaft, high efficiency (IE3) TEFC of matching capacity of squirrel cage induction motor, complete with all the accessories like base frame, antivibration pad coupling, interface fasteners, matching flanges etc.

3

-

-

... More
od313216/2022_2023 : MS C-Class Chilled water supply and return line manifold including all the fittings like bends. include Pipes, Insulation, Valves,Stainers, Pressure gauge, Temperature gauge, Steel structure and other required items as per SLD

250

-

-

... More
VIBRATION ISOLATION

-

-

-

... More
od284262/2022_2023 : Site measurements for Frequency domain analysis before and after developing the site.

2

-

-

... More
od284263/2022_2023 : Supply, installation, testing and commissioning of vibration Isolation Systems for FESEM.

1

-

-

... More
od284264/2022_2023 : Supply, installation testing and commissioning of vibration Isolation Systems for AFM.

1

-

-

... More
od284265/2022_2023 : Supply, installation, testing and commissioning of vibration Isolation Systems for MASK WRITER.

1

-

-

... More
od312311/2022_2023 : Design, supply, installation, testing and commissioning of a hybrid isolation system should be constituted by two or more isolation systems to isolate all ducts from the concrete structure of the building. Material to be used: Ethylene-propylene-diene terpolymer and rubber. Proper design to damp max possible vibrations below 200Hz.

1

-

-

... More
BMS

-

-

-

... More
od287175/2022_2023 : SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 50mm x 50mm cable tray GI powder coated for running of singnal and communcation cabling along with tray support and acessoroes.24 G.

700

-

-

... More
od287195/2022_2023 : Supply, installation, testing and commissioning of 100mmx 50mm cable tray GI powder coated for running signal and communication cable - 24 G.

400

-

-

... More
od287691/2022_2023 : Supply, installation, testing and commissioning of Heavy PVC conduit of 25mm dia with fittings, elbows support etc. for signal and communication cable .

5700

-

-

... More
od288410/2022_2023 : Supply, installation, testing and commissioning of DDC controller for Fire detection and suppression as per detailed specification.

1

-

-

... More
od288411/2022_2023 : Supply, installation, testing and commissioning of DDC controller for Exhaust system and scrubbers as per detailed specifications.

1

-

-

... More
od288412/2022_2023 : Supply, installation, testing and commissioning of Clean room temperature and RH sensor - Accuracy: Temp. +/- 0.2 Deg C, RH% +/-1 for all cubicals/labs.

9

-

-

... More
od288413/2022_2023 : supply, installation, testing and commissioning of Clean room positive pressure sensor, Range - 0 to +35 Pa.

9

-

-

... More
od288414/2022_2023 : Supply, installation, testing and commissioning of AHU Temperature sensors cum transmitters with all fittings and SS316 thermo-well etc. - AHUs and MAUs inlet; outlet CHW line.

10

-

-

... More
od288415/2022_2023 : Supply, installation, testing and commissioning of Differential pressure sensors across filters - AHUs and MAUs.

16

-

-

... More
od288416/2022_2023 : Supply, installation, testing and commissioning of Three way flow control valve with control sensor and actuator - AHUs & MAUs.

5

-

-

... More
od288417/2022_2023 : Supply, installation, testing and commissioning of Pressure gauge with isolation valve AHUs and MAUs - inlet & outlet CHW line.

10

-

-

... More
od288418/2022_2023 : Supply, installation, testing and commissioning of Temperature gauges with all fittings and SS316 thermowell etc. AHUs & AMUs inlet & outlet CHW line.

14

-

-

... More
od288419/2022_2023 : Supply, installation, testing and commissioning of Thermostat in redundant arrangement - AHUs and MAUs - near heaters.

5

-

-

... More
od288420/2022_2023 : Supply, installation , testing and commissioning of Air stat - AHUs and AMUs.

5

-

-

... More
od288421/2022_2023 : Supply, installation, testing and commissioning of Motorized actuator for smoke/fire dampers -at suction of the AHUs.

4

-

-

... More
od288422/2022_2023 : Supply, installation, testing and commissioning of Thyristors control of heaters - AHUs.

5

-

-

... More
od288424/2022_2023 : Supply, installation, testing and commissioning of MAU Motorized actuator smoke/fire dampers MAU outlet.

1

-

-

... More
od288425/2022_2023 : Supply, installation, testing and commissioning of Differential pressure sensor across filters Pre-filter1, pre-filter2, micro-filter, HEPA filter for all ahu and mau.

15

-

-

... More
od288426/2022_2023 : Supply, installation, testing and commissioning of Pan Humidifier HUMIDITY SENOSR in redundant arrangement - MAU.

1

-

-

... More
od288427/2022_2023 : Supply, installation, testing and commissioning of Thermostat in redundant arrangement In the heater chamber.

1

-

-

... More
od288428/2022_2023 : Supply, installation, testing and commissioning Heater, Tubular type with sufficient capacity to raise the temperature of air to Clean room temperature.

1

-

-

... More
od289113/2022_2023 : Supply, installation, testing and commissioning of Flow meter for measurement of airflow at the MAU outlet - Outlet of MAU.

1

-

-

... More
od289114/2022_2023 : Supply, installation, testing and commissioning of Airstat at the outlet - MAU duct as per detailed specification.

1

-

-

... More
od289115/2022_2023 : Chiller Plant :Supply, installation, testing and commissioning of Motorised butterfly valves - At the chilled water outlet line of each chiller and should be controlled from BMS.

3

-

-

... More
od289116/2022_2023 : Supply, installation, testing and commissioning of Temperature sensors cum transmitters with all fittings and SS316 thermo-well etc. - In the main supply and return header.

8

-

-

... More
od289117/2022_2023 : Supply, installation, testing and commissioning of Pressure gauge with isolation valve - Inlet & outlet of chillers.

6

-

-

... More
od289118/2022_2023 : Pressure gauge with isolation valve - suitable for Inlet & outlet of pumps.

6

-

-

... More
od289119/2022_2023 : Supply, installation, testing and commissioning of Temperature gauges with all fittings and SS316 thermowell etc.- Inlet and outlet of chillers.

6

-

-

... More
od289120/2022_2023 : Supply, installation, testing and commissioning of Temperature gauges with all fittings and SS316 thermowell etc.- In the main supply and return header.

4

-

-

... More
od289121/2022_2023 : Supply, installation, testing and commissioning of "Differential pressure sensor across the chillers - Evaporator- Chilled water inlet and outlet line of Evaporator of chillers.

3

-

-

... More
od289122/2022_2023 : Supply, installation, testing and commissioning of Level switch - Expansion tank.

1

-

-

... More
od289123/2022_2023 : Supply, installation, testing and commissioning of Clean Room Display Unit.

9

-

-

... More
od289124/2022_2023 : Supply, installation, testing and commissioning of operator work station, PC with i7 intel + 32 GB RAM + 2 TB harddsk+24 inch monitor and Laser printer.

1

-

-

... More
od289125/2022_2023 : Supply, installation, testing and commissioning of Switch for BMS 4/8 port.

20

-

-

... More
od289126/2022_2023 : Supply, installation, testing and commissioning of Communication Cabling with complete accessories fro ddc to mcc and vice versa.

4500

-

-

... More
od289127/2022_2023 : Supply, installation, testing and commissioning of Signal Cabling with complete accessories from ddc panel to field devices.

1200

-

-

... More
od289128/2022_2023 : Termination of signal and communication cables with complete glans as per OEM field devices and equipment specs.

300

-

-

... More
od291205/2022_2023 : Supply, installation, testing and commissioning of DDC Controller with Panel for AHUs.

4

-

-

... More
od291206/2022_2023 : Supply, installation, testing and commissioning of DDC Controller with Panel for MAUs.

1

-

-

... More
od291207/2022_2023 : Supply, installation, testing and commissioning of DDC Controller for Air cooled chillers ( 2w+1s).

3

-

-

... More
od291208/2022_2023 : Supply, installation, testing and commissioning of DDC controller for Pumps ( 2w+1s).

3

-

-

... More
od291209/2022_2023 : Supply, installation, testing and commissioning of Temperature, RH and Dew point meter - Accuracy: Temp. +/- 0.2 Deg C, RH% +/-1 - Outlet of MAU.

1

-

-

... More
od294284/2022_2023 : Supply, installation, testing and commissioning of BMS Software.

1

-

-

... More
Gas and fire safety with suppression system

-

-

-

... More
od290131/2022_2023 : Supply, installation, testing and commissioning of "Main Fire Alarm Panel: Analogue Addressable 2Loop Expandable upto 6 loops with HOT REDUNDANT CPU and TFT visual display of 5.7 capacitive<br>keyboard for touch sensitive operation and as per detailed spec.

1

-

-

... More
od290132/2022_2023 : Supply, installation, testing and commissioning of Repeater panel with connected peer to peer with Main Fire Alarm<br>panel. Large Display such that the status of the entire system can be available on individual panel and as per detailed specification.

1

-

-

... More
od290133/2022_2023 : Supply, installation, testing and commissioning of Multi sensor DUAL ANGLE IR transmitter type detector with isolator base 15 degree F to 20 degree F per minute or Fixed temperature as required with base.

1

-

-

... More
od290134/2022_2023 : Supply, installation, testing and commissioning of Loop power addressable type sounder & flasher with in built isolator.

6

-

-

... More
od290135/2022_2023 : Supply, installation, testing and commissioning of "Monitor & control module with 1 IN /1 OUT with Inbuilt Isolator with required junction box.

8

-

-

... More
od290136/2022_2023 : "Supply of seamless cylinder having capacity 140 Litres to fill NOVEC 1230 gas with Valve. UL Listed.

2

-

-

... More
od290137/2022_2023 : "Supply of seamless cylinder having capacity 80 Litres to fill NOVEC 1230 gas with Valve. UL Listed.

6

-

-

... More
od290138/2022_2023 : "Supply of seamless cylinder having capacity 120 Litres to fill NOVEC 1230 gas with Valve. UL Listed.

4

-

-

... More
od290875/2022_2023 : "Supply, installation, testing and commissioning of Gas Detector: The Type : 3-wire, 4-20 mA, fixed point gas detector, with catalytic Electrochemical sensor and as per detailed specification.

1

-

-

... More
od290876/2022_2023 : Supply, installation, testing and commissioning of Extractive Transmitter.

32

-

-

... More
od290877/2022_2023 : Supply, installation, testing and commissioning of N2O sensor Range 100-1000 ppm.

2

-

-

... More
od290878/2022_2023 : Supply, installation, testing and commissioning of CH4 sensor Range 6.5-100% LEL.

2

-

-

... More
od290879/2022_2023 : Supply, installation, testing and commissioning of C2H2 sensor Range 6.5-100% LEL.

2

-

-

... More
od290880/2022_2023 : Supply, installation, testing and commissioning of H2 sensor Range 90-1000 ppm.

2

-

-

... More
od290881/2022_2023 : Supply, installation, testing and commissioning of NH3 sensor : Ammonia (NH3) sensor Range 9-100 ppm.

2

-

-

... More
od290882/2022_2023 : Supply, installation, testing and commissioning of H2S sensor Hydrogen Sulfide (H2S) sensor Range 3.6-40 ppm.

2

-

-

... More
od290883/2022_2023 : Supply, installation, testing and commissioning of PH3 sensor Phosphine (PH3) sensor Range-110-1200 ppb.

2

-

-

... More
od290884/2022_2023 : Supply, installation, testing and commissioning of SiH4 sensor Silane (SiH4), sensor Range 0.18-2 ppm.

2

-

-

... More
od290885/2022_2023 : Supply, installation, testing and commissioning of Cl2 sensor Chlorine (Cl2) sensor, Range 0.18-2 ppm.

2

-

-

... More
od290886/2022_2023 : Supply, installation, testing and commissioning of B2H6 sensor Range 0036-0.4 ppm.

2

-

-

... More
od290887/2022_2023 : Supply, installation, testing and commissioning of SF6 sensor MST SENSOR SF6 Range 0-0.5%-VOL (PYROLYZER).

2

-

-

... More
od290888/2022_2023 : Supply, installation, testing and commissioning of "Cable and accessories : Inlet Tubing, FEP Teflon 100' 1/4 x 1/8, Exhaust Tubing, Poly 100; 1/4 OD, SYSH safe area Horn and strobe, Gas Control panel suitable for 24nos of detector, Cable Glands etc.

2

-

-

... More
od291667/2022_2023 : Supply, installation, testing and commissioning of BCl3 sensor.

2

-

-

... More
od291668/2022_2023 : Supply, installation, testing and commissioning of CHF3 sensor.

2

-

-

... More
od291714/2022_2023 : Supply, installation, testing and commissioning of Manual call point with inbuilt isolator.

6

-

-

... More
Camera and Access control

-

-

-

... More
od311186/2022_2023 : supply, installation, testing and commissioning of bio metric access control system to open and lock doors as per detailed specification.

4

-

-

... More
od311187/2022_2023 : supply, installation, testing and commissioning of 5 MP or more IR Mini Bullet Camera,5MP high resolution, HD 720p real-time video, Up to 30m IR visibility, True day/night, 3D DNR & DWDR & BLC, IP66 rating ( for out door camera ), IR 60 Mt,24 VAC/PoE power supply Vandal-proof housing.

1

-

-

... More
od311188/2022_2023 : Supply, installation, testing and commissioning of 5 MP PTZ Dome Network Camera,1/3’’ Progressive Scan CMOS,1280 × 960 HD resolution,30X / 20X optical zoom, 16X digital zoom, True Day/Night, 3D DNR, Digital WDR, 3D intelligent positioning,24VAC / PoE+ power supply

7

-

-

... More
od311189/2022_2023 : supply, installation, testing and commissioning of 16 port NVR, Up to 5 Megapixels resolution recording, HDMI and VGA output at up to 1920×1080P resolution, 8-ch network cameras can be connected with25M/50M/100M incoming bandwidth, Up to 2 SATA interfaces.

1

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

800

-

-

... More
od324324/2022_2023 : Supply, Installation, testing and commissioning of Category 6 U/UTP Multi-Stranded Patch Cable 1M(LSZH)

72

-

-

... More
od324325/2022_2023 : Supply, installation, testing and commissioning of Category 6 24 Port loaded Patch panel supporting with rear cable manager.

3

-

-

... More
od324326/2022_2023 : Supply, installation, testing and commissioning of Category 6 UTP I/O Female Module.

22

-

-

... More
od324327/2022_2023 : Supply, Installation, Testing and Commissioning of PDU 1Ph, 230V, 16A, 50/60Hz, 2U standard with 6 X Indian Round Pin 5/15A, Inlet Plug type 16A Indian Round Pin, 16A MCB - PDU

2

-

-

... More
od324328/2022_2023 : Supply, Installation, Testing and Commissioning of 9 U Wall Mount Rack 600D with Cooling Fan -2 Qty, Hardware Kit with Mounting Accessories.

3

-

-

... More
od324498/2022_2023 : Supply, installation, testing and commissioning of 24-port 100/1000T stackable fully managed switch with 4 SFP+ ports as per specification.

1

-

-

... More
od324499/2022_2023 : Supplying, Erection in the existing concealed box / modular of Dual Port Faceplate for CAT 6 .It shall be include necessary accessories like screw, proper labelling with color code, etc ., as complete all respects complying with relevant standard specification.

22

-

-

... More
od324500/2022_2023 : Supply, Installation, Testing &amp; commissioning of 24 port Network POE 370 W Class 4 Switch with accessories.

1

-

-

... More
od325272/2022_2023 : Supply, Installation, Testing and Commissioning of 55 Inch Commercial Display Panel Resolution 3840 X 2160 (UHD) ,Brightness -400 , 2 HDMI ,2 USB With Mount Kit (Approved Make: LG/Samsung).

1

-

-

... More
od325524/2022_2023 : supply, installation, testing and commissioning of 5 MP or more IR Mini Bullet Camera,5MP high resolution, HD 720p real-time video, Up to 30m IR visibility, True day/night, 3D DNR & DWDR & BLC, IP53 rating (indoor camera ), IR 30 mtr

3

-

-

... More
Process chiller, DI water, srubber and RO plant

-

-

-

... More
od312098/2022_2023 : supply, installation, testing and commissioning of exhaust system of 150 mm dia CRC coated PVC duct should be laid above false ceiling.

1

-

-

... More
od312099/2022_2023 : Design and erection of drainage system. Both water and chemical<br>drainage should be laid separately as per approved drawing

1

-

-

... More
od312100/2022_2023 : Supply, installation, testing and commissioning of A Scrubber for the disposal of PECVD and RIE plasma system Exhaust by products used with below gases is required.Bidders should Design, Supply, Install and Test the Scrubber. The scrubber should have following:i. Chemisorption or hot bed reaction based dry scrubbing technology. ii. At the outlet of scrubber, the toxic gases concentration should be below their universally accepted Threshold Limit Values (TLVs)It should not require any utility such as water etc. for its operation. iv. At the outlet of the scrubber, it should have detectors/ gas analyser<br>to detect minimum gas concentration of their universally accepted TLVs v. It should also have alarm / buzzer system to generate audio or visual signals when gas concentration gets equal (or above) to their universally accepted TLVs at the outlet of the scrubber. vi. It should allow for safe refilling / replacement of cartridges consumables. vii. It should have Overpressure Safety switch and alarm.viii. Systems will use total of 100 SLPM of N2 Purge for dry pumps

1

-

-

... More
od312101/2022_2023 : Supply, installation, testing and commissioning of Stainless Steel ( SS304 grade) vacuum lines of 1 inch diameter. Number of ports. Valve at each port

1

-

-

... More
od312102/2022_2023 : Supply and Installation of Vacuum pump of capacity 500 Lit/min, completed with suitable rating of motor and control panel or<br>more. required vacuum: 0.1 mbar

1

-

-

... More
od312103/2022_2023 : Supply, installation, testing and commissioning of chilled water pipe line Properly insulated supply and return water lines with ports for supply and return at each point near the equipment where chill water is<br>required. Pipe: 20 mm dia stainless steel pipe inside labs with proper Clean<br>Room compatible insulation.

1

-

-

... More
od312104/2022_2023 : Supply, installation, testing and commissioning of Chiller of cooling capacity: 20 TR, control panel,Tank size: 200 Lit

1

-

-

... More
od312105/2022_2023 : Supply, installation, testing and commissioning of DI water tank to three point of use. Capacity 1.5 – 2 Lit /min flow

1

-

-

... More
od312106/2022_2023 : Supply and Installation of De-ionised Plant for Clean Labs. The Feed<br>Water will be from RO plant and The system should produce Type 1<br>and Type 3. The system should provide premium product water quality at all times. Should be optimized for economic water consumption. Should have Guaranteed longer life of down-stream ultrapure water systems

1

-

-

... More
od312107/2022_2023 : Design and erect PVC tube pipeline of 25mm from RO plant over head tank to all the points where RO water is required. All wet benches/Fume hoods have points for water. All required job should be complete with all the required fittings as per approved drawing.

1

-

-

... More
od312108/2022_2023 : Supply and installation, testing and commissioning of RO water Purification Plant should<br>have following specifications. The plant should be capable of removing 90-99% of total dissolved solid (TDS), 99% of organic, including pyrogens, and 99% of all bacteria in the feed water. TOC level should be less than 50 ppb. The removed impurities should be concentrated in the reject stream and flushed to drain. The capacity of the plant should be more than 10 lit/Min. Should have Microprocessor controlled system with continuous water purity monitoring. Touch screen panel to set the parameters. Alarm for cartridge change service check Online display of feed product quality. 300 liters tank with low & high level water control to store RO water for further distribution Suitable pump to pressurize purified water to fill tank. supply and instllation of Two tanks (500 liters each) to store purified water at specified location

1

-

-

... More
od312109/2022_2023 : Supply, installation, testing and commissioning of Oil Free Screw Type Compressor. Oil free air compressors should deliver 100% oil free compressed air, in compliance with the stringent norms of ISO 8573 -1 Class 0 and ISO<br>8573-7, Oil free air compressors should have Low starting current, High efficiency, Reduced mechanical wear, Minimum maintenance, Smooth start and Smooth control, Free Air Delivery (FAD) should be tested as per ISO 1217 : 2009 - Required Specifications are Nominal Power: 15kW /20HP, Working line pressure:10 bar / 150 psi or more, Air free delivery: 1.50 m3/min / 55 CFM or more, Noise Level: 72 dB or less at a distance of 1meter,

1

-

-

... More
Earthworks

-

-

-

... More
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil

49.86

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

59.83

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

10

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

74.79

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

10

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

321

-

-

... More
Concrete Works

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

3.46

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

27.55

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

21.18

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

36.32

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

10

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

2891.4

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1377.5

-

-

... More
Structural Steel works

-

-

-

... More
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

30519.44

-

-

... More
od314025/2022_2023 : Designing, providing, installing and fixing prefabricated structural steel work riveted, bolted, or welded in built up sections, trusses, Bracings, and framed work including supply and fixing of anchor bolts, base plates, cutting, hoisting, fixing in position and applying a priming coat of approved steel primer for epoxy painting and 2 coats of epoxy painting with approved quality epoxy paint all complete. The steel structure is to be designed fabricated, supplied, and erected through Pre-Engineering and the design shall be got approved from Client.

34475.6

-

-

... More
10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube

10

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

200

-

-

... More
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)

50

-

-

... More
Demolition and dismantling works

-

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

10

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

10

-

-

... More
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below

5

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

50

-

-

... More
od312848/2022_2023 : Dismantling of Structural Glazing system carefully and stacking the serviceable materials at stockyard within the campus complete as per directions of the Engineer in charge.

10

-

-

... More
15.17.2 : Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:Channels, angles, tees and flats

250

-

-

... More
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

109.03

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

50

-

-

... More
16.82 : Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

20

-

-

... More
16.83 : Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.

36

-

-

... More
od313206/2022_2023 : Dismantling water closet carefully, clearing away and stacking the material in the stockyard within campus as per directions of Engineer-in-charge

3

-

-

... More
od313207/2022_2023 : Dismantling wash basin, sink etc. carefully, clearing away and stacking the material in the stockyard within campus as per directions of Engineer-in-charge

3

-

-

... More
od313208/2022_2023 : Dismantling urinal carefully, clearing away and stacking the material in the stockyard within campus as per directions of Engineer-in-charge

1

-

-

... More
od313209/2022_2023 : Dismantling fixtures such as Pillar cock, sink cock, health faucet, valves etc carefully, clearing away and stacking the material in the stockyard within campus as per directions of Engineer-in-charge

16

-

-

... More
od313210/2022_2023 : Dismantling consealed pipe lines (including supply & waste lines) carefully, clearing away and stacking the material in the stockyard within campus as per directions of Engineer-in-charge

10

-

-

... More
od313211/2022_2023 : Dismantling mirror carefully and stacking in the stackyard within 50 meters lead as per directions of Engineer-in-charge.

1

-

-

... More
od313212/2022_2023 : Dismantling toilet paper holder carefully and stacking the material in the stackyard within 50 meters lead as per direction of Engineer-in-charge

3

-

-

... More
od314158/2022_2023 : Dismantling carefully HVAC indoor units (6 nos) located in proposed Cleanroom area after discharging of gas, ducts nearly 75 long, related piping, cabling and other accessories etc complete, listing and stacking the dismantled materials in the stockyard as per directions of Engineer-in-charge

1

-

-

... More
Finishing works

-

-

-

... More
13.48A.1 : Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

700

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

200

-

-

... More
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

10

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

10

-

-

... More
13.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre

10

-

-

... More
11.41.4 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm

10

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

10

-

-

... More
Interior Works

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

10

-

-

... More
od310637/2022_2023 : Providing & laying Fire Retardant Carpet Flooring of 100% Nylon Type 6, material Carpet tile of nominal thickness of 4-5 mm with size of 500 mm x 500 mm respectively of approved make Welfsun carpet or equivalent. Completely & neatly finished. Tile size may be approved with minimal tolerance limits as provided by the Manufacturer's specification (Basic Rate:1345.50)

82.5

-

-

... More
od310641/2022_2023 : Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'HILTI' make diamond drilling machine with tolerance for any type of inser ts, anchor fasteners etc. Rate shall include for sealing the gaps between RC surface and inser ts with fire retardent grouting material as per manufactures specification ,all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete,as directed. 110 to 160 mm dia pipe to the following depth:150 mm Depth

5

-

-

... More
od310645/2022_2023 : Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'HILTI' make diamond drilling machine with tolerance for any type of inser ts, anchor fasteners etc. Rate shall include for sealing the gaps between RC surface and inser ts with fire retardent grouting material as per manufactures specification ,all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete, as directed. -75 to 110 mm dia pipe to the following depth:-150 mm Depth

5

-

-

... More
od310646/2022_2023 : Providing and fixing of 3M frosted film of approved color as per required pattern and shape and as directed. The vendor shall submit required warranty certificates from the manufacture. (Basic cost Rs.1200/Sqm)

13.37

-

-

... More
od310650/2022_2023 : Providing and fixing partition having 98 mm overall thickness with gypsum plasterboard 13mm thick USGKnauf Boral Multistop plaster board/ Gyproc Habito board or equivalent, including frame work made of special sections power pressed/ roll form G.I. sheet with Zinc coating of 120/150 gsm , consisting of floor and ceiling channel 32x72x32x0.5 mm size 72 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 34x70x36x0.5 mm 70mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, noggin channel 40x70x40x0.5mm as required, insulation to be provided with Resin Bonded rock wool conforming to IS: 8183, having density 48 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to boards with screw, rawl plug &amp; washers and held and in position by criss crossing GI wire and fixing of gypsum board on both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre, with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher, and two coats of primer suitable for board as per manufacturer&apos;s specification, etc complete as per direction of Engineer-in-charge. The junction of the partition with masonry &amp; all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant. Note: Area from FFL to bottom of false ceiling height only will be measured for payment.

44

-

-

... More
od310651/2022_2023 : Providing and fixing tiled false ceiling of GI Metal Ceiling Lay in perforated Tegular edge global white/black/wooden colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm dr op; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece., in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stitched double webbed with 6mm reveal profile (colour as per site condition and direction of EIC), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm.Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main &quot;T&quot; runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.

95

-

-

... More
od310652/2022_2023 : Providing and fixing false ceiling using 12.5 mm thick tapered edge gypsum moisture resistant board conforming to IS : 2095-Part 1 at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120-150 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts &amp; bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, providing vertical edges for a depth of 100 mm at junctions of different type of ceilings, concealed cove lighting etc as per design including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint, applying plaster of paris putty to prepare even and smooth, two coats of primer suitable for board, painting two or more coats with premium acrylic emulsion paint having VOC content less than 50 grams/litre of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour, all as per manufacturer&apos;s specification and also including the cost of making openings for light fittings, cove lighting, profile lighting, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge Note: The plan area only will be measured for payment

38.72

-

-

... More
od310653/2022_2023 : Providing and fixing false ceiling using 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS : 2095-Part 1 at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120-150 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts &amp; bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, providing vertical edges for a depth of 100 mm at junctions of different type of ceilings, concealed cove lighting etc as per design including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint, applying plaster of paris putty to prepare even and smooth, two coats of primer suitable for board, painting two or more coats with premium acrylic emulsion paint having VOC content less than 50 grams/litre of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour, all as per manufacturer&apos;s specification and also including the cost of making openings for light fittings, cove lighting, profile lighting, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge Note: The plan area only will be measured for payment

143

-

-

... More
od310654/2022_2023 : Providing and fixing 12 mm thick frameless toughened glass door with corner hinges and other fixtures of Dorma make or equivalent. The rate shall be including providing and fixing corner hinges with all accessories, , door closer with slide channel and universal saddle plate, centre lock with euro profile cylinder keys 3 nos, strike patch for lock, 600 mm pull handle SS Satin finish of shape to be approved by Engineer-in-charge, making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge

5.81

-

-

... More
od310655/2022_2023 : Providing and fixing Single glazed partitions with 12mm thick toughened glass as per drawings using Dormakaba ALTERRA LITE System 45 Frames or any equivalent brand to a height of maximum 3 m that shall be able to provide a sound reduction of 36.7 dB. The glass panels shall be supported by Aluminium WCP Profiles of 25x45mm having 2 mm gauge thickness on all 4 sides of the Glass partition perimeter. Glass-to-glass butt joints shall be provided with Suitable junction profiles are to be used at glass-to-glass joints such as H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design. Finishes of all aluminium frame components shall be Black Anodized Finished (20 microns). At the location of doors, End Profile frame of size 45 x 50 mm shall be provided around the door two vertical upto false ceiling and horizontal at door top. Adjacent to the door frame, suitable service profile to be provided for installing the access control system as per requirement. Rate shall include for providing and fixing necessary support arrangement to ensure proper anchorage / fixing to the ceiling/partition to get sufficient rigidity (to the required level). Rate shall include for transport charges, handling, loading and unloading, installation of glass and protecting the module and glass till handing over, testing, commissioning all necessary hardware, Structural supports, scaffolding, wastage, etc. complete and all as per manufacturers specifications as directed. The vendor has to prepare the shop drawing for approval of Engineer-in-charge. Note : Only the clear elevation area below the false ceiling level shall be considered for measurement and payment

32

-

-

... More
od310656/2022_2023 : Providing and fixing partition above false ceiling, at locations of glass partitions, made out of aluminium box frame using extruded sections of size 50 x 25 mm - 1.5mm thick at 600mm c/c in both direction covered with panelling on both sides with 12.5 mm thick tapered edge gypsum fire resistant board including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture&apos;s specification and insulation to be provided with Resin Bonded rock wool conforming to IS: 8183, having density 48 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to boards with screw, rawl plug &amp; washers and held and in position by criss crossing GI wire as per directions of Engineer-in-charge. Rate shall include cost for necessary hardwares and shall include for forming a panelling to any shape including circular profile etc. complete. Actual seen surface area.(i.e) from false ceiling to true ceiling height will be measured and paid.

33

-

-

... More
od312854/2022_2023 : Refixing of Dismantled doors (steel or wood ) frame and shutter including chowkhats, architrave, holdfasts etc. complete as directed by Engineer In Charge<br>Of area 3 sq. metres and below

3

-

-

... More
Furniture

-

-

-

... More
od310632/2022_2023 : Supply and installation of Executive work chairs reolving , with adjustable arm rests, gas lift, SS leg and SS or fiber five spoke base, lumbar support, mesh back covered , with head rest , hi back or hi mid back series from approved brands like Featherlite/Godrej/Monarch/ Wipro etc. with proven track record under works with Kerala IT Parks to ensure quality and standards. Chairs are to have ergonomic designs.

1

-

-

... More
od310633/2022_2023 : Supply and installation of visitor chairs with SS legs non revolving, with lumbar support, mesh back or leatherite covered , without head rest ,medium back series from approved brands like Featherlite/Godrej/Monarch/ Wipro etc. with proven track record under works with Kerala IT Parks to ensure quality and standards. Chairs are to have ergonomic designs.Visitor chairs chosen shall also be in sync with Executive chair models selected for better aesthetics.

6

-

-

... More
od310634/2022_2023 : Supply and fixing of Officer Tables not less than sizes 1800 x 900 with side unit, made by pre-laminated MDF table tops and sides and standard steel members in main support members. Items may be selected from brochures of approved brands like Godrej/Featherlite/Wipro/Monarch etc. which are companies running under Green certification protocol.Dimensions and finishes shall be as per standards followed in government owned Kerala IT park premises

1

-

-

... More
od310636/2022_2023 : MEETING / CONFERENCE CHAIRS- Providing High Back executive chair, Knee Tilt KT Mechanism, Adjustable Armrest, Upholstered Seat & Mesh Back, Gas lift for Seat height adjustment, Nylon base with Castors, Upholstery: Black Fabric With Head Rest

10

-

-

... More
od310638/2022_2023 : Conference Room Table (4200x1200x750).Providing and installing Conference table with pre-laminated particle board of size 4200 mm X 1200 mm X 750mm .The table to be constructed with 100 mm thk pre-laminated particle board wood and finished of approved color, the table corners to be tappered with the laminate and necessary provision for cable basket as per drawing to detail. The table supported vertically in box type with 18mm pre-laminated particle board wood of size 450 x 750 with a flat base support of size 600 x 900 mm all finished with pre-laminated particle board . the edges of the base plate to be tappered as per the detail dwg neatly and complete.

1

-

-

... More
od310639/2022_2023 : LAB Chair : Providing and fixing chair of size W x H x D (cm)-75 x (88 - 98) x 75 or nearest with Glass filled Polypropylene<br>Upholstery Material having seat height 41 – 51 cm as complete as per technical specification and as directed by engineer in charge.<br>

5

-

-

... More
od310640/2022_2023 : Working Platform with SINK: Providing and fixing working platform with Size: 1800x700x900 mm or nearest with stainless steel 304 grade sink with drain board of size 510x1040 mm bowl depth 250 mm with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Table top shall be pre-moulded mirror polished granite as complete as per technical specification and as directed by engineer in charge.

1

-

-

... More
od310642/2022_2023 : TABLE for Unclassified LAB: Providing and Fixing Tables not less than sizes 1800 x 900 , made by mirror polished pre-moulded granite table top complete as per technical specification and as directed by Engineer in charge.

6

-

-

... More
od310644/2022_2023 : CLEAN ROOM TABLE: Providing and fixing clean room table of size 1200 W x 600 D x 900 H mm or nearest having Cleanroom Class 100 compatible tabletop with perforated worktop complete as per technical specification and as directed by engineer in charge.

6

-

-

... More
od310647/2022_2023 : CLASS 100 CR & ESD STOOL WITH FOOTRING: Providing and fixing clean room stool of Seat size: diameter 382mm or nearest. Material shall be PU sponge upholstered with clean room compatible leather. It shall conforms to class -100/ ISO -5 Cleanliness standard and as complete as per technical specification and as directed by Engineer in charge.

8

-

-

... More
od310649/2022_2023 : CLASS 100 CR & ESD CHAIR WITH FOOTRING: Providing and fixing Clean room compatible chair of W x D (453 x 420mm) or nearest size. Material shall be PU sponge upholstered with Clean room compatible leather. Back rest size shall be : W x H (400 X 355mm) or nearest. Chair shall conform to class -100/ ISO -5 Cleanliness standard as complete as per technical specification and as directed by the Engineer in Charge.

8

-

-

... More
Miscellaneous Roads

-

-

-

... More
2.4.10.A : Removing all type of Hume Pipes and Stacking within a lead of 1000 metres including Earthwork and Dismantling of Masonry Works - Up to 600 mm dia.

10

-

-

... More
2.5.1.B : Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately br Granular courses - By Manual Means.

50

-

-

... More
od311827/2022_2023 : Relaying of dismantled Multi groove Paver tile of size 500 x 250mm x 40mm thick of Besant beton / approved make in all colours, finish, laid on 20mm thick bed of Cement Mortar 1:3 (1 Cement : 3 Coarse sand) including pointing the joints with cement etc., complete. Work include for preparation of base surface & finished the surface as directed.

18.15

-

-

... More
od311828/2022_2023 : Construction of granular sub-base by relaying excavated close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-30

9.08

-

-

... More
od311829/2022_2023 : Relaying, spreading and compacting excavated graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge

9.08

-

-

... More
Clean Room Interior Works

-

-

-

... More
od314283/2022_2023 : supply and installation of Garment Cubical (Dynamic type) made of SS-304. Garment Storage Locker with Vertical Down flow type, modular construction made out of GI duly Powder coated. Approximate Dimension: Overall Size- 1000 mm (w) x 600 mm (d) x 2100 mm (h), with door and view window including Blower, Motor and stages of Filters complete as directed by engineer in charge

4

-

-

... More
od314284/2022_2023 : Supply and installation of Flexible ductwork, un-insulated complete with SS duct bands and duct band locks of size matching with the filter’s inlet collar complete as directed by engineer in charge

350

-

-

... More
od314285/2022_2023 : Supply and installation of Individual manual Aluminium circular dampers of size matching with the terminal filter’s inlet collar complete as directed by engineer in charge

225

-

-

... More
od314286/2022_2023 : Supply and installation of Bottom Wall return Air Grills with dampers for installation in Clean Room Walls neatly complete as directed by engineer in charge

45

-

-

... More
od314287/2022_2023 : Supplying and installation of Double glass sealed powder coated View Panels well designed and neatly manufactured of Size: 1200 x 1200 mm on 80mm partition wall neatly complete as directed by engineer in charge

10

-

-

... More
od314288/2022_2023 : Supplying and installation of Double glass sealed powder coated View Panels well designed and neatly manufactured of Size: 1200 x 1200 mm on 50mm partition wall neatly complete as directed by engineer in charge

12

-

-

... More
od314289/2022_2023 : Supply and installation of Double glass sealed Box type Powder coated View Panels well designed and neatly manufactured of Size: 1200 x 1200 mm (on 300mm partition wall) complete as directed by engineer in charge.

14

-

-

... More
od314290/2022_2023 : Supply, Installation, Testing and Commissioning of Air Shower. The Air shower should have one IN and one OUT doors. The dimensions of the air shower shall be sufficient for two-person entry. Material of construction of Air shower shall be SS304. The air shower shall be compatible with Clean Room Class 100. Door interlocking arrangement should permit opening of only one door at a time. During operation, neither entrance nor exit door should be operated. A lock switch for overriding the electronic control system ensuring manual operation should also be provided. The air shower shall be provided with per filter of HDPE, Washable type with efficiency 90% down to 10 micron and HEPA filter with efficiency of 99.97% down to 0.3 microns etc and complete as directed by engineer in charge

2

-

-

... More
od314291/2022_2023 : Supply and installation of Wet Benches in Clean Lab-1, Lab-2 and lab-4. The installation should be inclusive of individual ducting with blower at the terrace of the building. Polypropylene Class 100 Wet Chemical Station should have the following specs:1. Material of construction is 10mm thick natural Polypropylene laminated sheets.2. Adjustable levelling feet.3. An operator safety visor made of 6 mm thick clear acrylic sheet with PP frame, which is fixed in front of the bench and can be opened/closed.4. Polypropylene drain of size 40mm with union connection will be provided at bottom of the sink base for draining.5. Polypropylene C-Channels will be incorporated for improving strength & rigidity of wet bench.6. All materials selected for application in the most demanding of conditions and are suitable for a cleanroom application. 7. FFU(Fan Filter Unit) Al Zinc Alloy constructed FFU to provide class 100 clean air inside the wet bench. to use imported Fan Filter module with HEPA filters. air flow rate varies from 460-760 CFM.8. HEPA filter are rated 99.99% efficiency in removing 0.3μ or larger particles. Pre Filter are rated 90% efficiency in removing 10 to 15 Micron.9. Pre filters are made from non-woven materials.10. Worktop should be made of 10mm thick polypropylene sheet with perforation. Appropriate supporting ribs shall be given at the bottom of worktop to avoid deflection.11. One general usage Sink made of Polypropylene should be included with Gooseneck made of Polypropylene.12. Lighting: 2 normal yellow light for adequate illumination13. Bottom storage: The station should be provided with 2 nos. of storage cabinets with a partition for storing chemicals under the sink base. 14. Magnehelic gauge of 50mm of water column capacity to measure the differential pressure at the exhaust plenum box in fume hood.15. Electrical : Miniature circuit breakers (MCB) should be included.16. N2 spray guns of virgin PTFE material. Should have 1/4”FNPT Inlet thread, filter housing with disposable filter.17. DI water Gun constructed of virgin PTFE material Should have 1/4”FNPT Inlet thread.18. Exhaust port with properly designed CRC coated duct upto the terrace of building. Exhaust Blower: Suitable size FRP Centrifugal Blower @ 800 CFM @ 100 mm Aq complete with 3 ph TEFC Motor & all Std. accs & mountings. Civil foundation should be included complete as directed by engineer in charge

3

-

-

... More
od314292/2022_2023 : Providing and fixing cleanroom compatible gowning mirror of size 1200 mm height x 600 mm width or nearest complete with necessary hardware as directed by engineer in charge

1

-

-

... More
od314293/2022_2023 : Supply and Installation of Cross Over Bench, made out of SS 304 with 04 Grade Finish of size 300 mm X, 500 mm and 1500 mm (L) or nearest and complete as directed by Engineer in charge

3

-

-

... More
od314294/2022_2023 : Supply & installation of Shoe racks made out of SS 304 with 04 Grade Finish of size 300 mm X, 500 mm and 2000 mm (L) or nearest and complete as directed by Engineer in Charge

3

-

-

... More
od314295/2022_2023 : Supply and installation of Semi-automatic Shoe Cover Applicator and Remover of approved make and complete as directed by engineer in charge

2

-

-

... More
od314296/2022_2023 : Supply & installation of Clean Room Access Floor (Raised Floor) for Class 100 clean labs having following specifications: Clean Room access floor system shall be removable raised access system consisting of an assembly of perforated floor tiles mounted on adjustable pedestals to provide an under-floor space to accommodate mechanical service line, electrical conduits and to serve as an air supply and return plenum. The floor system shall be stringer-less, conductive type and shall include die-cast Aluminium perforated (with dampers as required) tiles, adjustable pedestals with grounding clips and conductive vinyl tile covering on the face of all floor tiles. The floor tile size is 600 x 600 x 50 mm thick. The height of raised floor will be 600 mm. The floor tiles shall be capable of carrying the following loads : Concentrated load > 650 Kg with deflection < 2.0mm; Uniform load > 1250 Kg/sq. m with deflection < 1.0mm; Rolling load > 200 kg/sq. m with deflection < 0.5mm; Ultimate load > 1575 kg/6.45 sq. cm at centre; Floor tiles shall be Aluminium die cast construction with static conductive vinyl, non-combustible chemical and abrasive resistant cover of minimum 2 mm thickness. Floor tiles system resistivity shall have a minimum value of 1.5x105 ohm and a maximum value of 2x107ohm between top structure of tile and under structure. Static conductive vinyl coating tile shall be fabricated in one piece. Floor tiles with dampers shall be to check/correct the uni-directional flow in the Clean Room. All tiles shall be completely interchangeable and easily removable with a lifting tool. Pedestals shall conform to the panel specifications with regard to the load bearing characteristic. Pedestals assemblies shall be capable of supporting a 2250 Kg axial load without any deformation. Pedestals shall be made from hard drawn Aluminium tube. Floor system pedestals and tiles shall be laterally stable in all the directions with panels in place or removed without the use of additional framing or stringers. Adjustment of pedestals to be provided by threaded rod member and an elevating collar of ± 25 mm. The pedestals head of Al die cast construction should provide positive interlocking of panels and pedestals to prevent lateral movement. Pedestal heads to be equipped with a conductive vinyl grounding pad. Pedestals are to be vertically true, located on centres to conform with size of panel to be equipped with locking device to prevent the loss of finished elevation. Installation of the floor system shall include the under floor plenum barriers as required, providing earth clamps and bare copper wire to earth all floor pedestals & interconnection and connecting the same to system earth in sub- fab through PVC insulated Copper earth cable of suitable X-section. Die cast aluminium access floor system, 300 mm height, Al pedestals, with minimum 2mm thick conductive vinyl covering including necessary earthing etc. required for installation all complete for following types. Perforated Panel with damper, 600 x 600 mm. Perforated panel without damper, 600 x 600mm complete as directed by engineer in charge

28.8

-

-

... More
od314297/2022_2023 : Supplying and installation of 100mm square plastic cut-out Moulding and sponge rubber/neoprene gasket in 100mm square cut-out on access floor, cut to fit cables by others complete as directed by engineer in charge.

15

-

-

... More
od314298/2022_2023 : Supply and installation of Anti-Static PVC Flooring with 2 mm thick homogeneous flexible antistatic PVC sheet tiles roll, with a resistance level of 1 x 10^6 to 1 x 10^9 ohms, suitable for Class 100 and Class 1000 Clean Room with a load carrying capacity of 750PSI (min.) confirming to BS 2050, with welded joints by thermo chord weld, including suitable copper strip (foil) grid of size 10' x 10' (approx.) as recommended by manufacturer and connecting to the earthing. Preparing of existing surface with plaster of Paris so as to make the surface free from any undulations, fixing the PVC tiles with conductive adhesive (Water based) as per manufacturer's recommendation, rolling with 100lb roller and sealing up the joints with fuse welding as recommended in the manufacturer's specification.

630

-

-

... More
od314299/2022_2023 : Supply and installation of Anti-Static PVC Flooring with 2 mm thick homogeneous flexible antistatic PVC sheet tiles of size 600x600 mm, with a resistance level of 1 x 10^6 to 1 x 10^9 ohms, suitable for Class 100 and Class 1000 Clean Room with a load carrying capacity of 750PSI (min.) confirming to BS 2050, with welded joints by thermo chord weld, including suitable copper strip (foil) grid of size 10' x 10' (approx.) as recommended by manufacturer and connecting to the earthing. Preparing of existing surface with plaster of Paris so as to make the surface free from any undulations, fixing the PVC tiles with conductive adhesive (Water based) as per manufacturer's recommendation, rolling with 100lb roller and sealing up the joints with fuse welding as recommended in the manufacturer's specification and complete as directed by Engineer in charge.

120

-

-

... More
od314300/2022_2023 : Supply and installation of ULPA filters, U15 as per EN1822 suitable for 600mm x 1200mm ceiling grid with complete housing and other accessory for installation as directed by Engineer in charge

45

-

-

... More
od314301/2022_2023 : Supply and installation of ULPA filters, U15 as per EN1822 suitable for 600mm x 600mm ceiling grid with complete housing and other accessory for installation as directed by Engineer in charge

5

-

-

... More
od314302/2022_2023 : Supply and installation of HEPA filters, H14 as per EN1822 suitable for 600mm x 1200mm ceiling grid with complete housing and other accessory for installation as directed by Engineer-in-charge

125

-

-

... More
od314303/2022_2023 : Supply and installation of HEPA filters, H14 as per EN1822 suitable for 600mm x 600mm ceiling grid with complete housing and other accessory for installation as directed by Engineer in charge

5

-

-

... More
od314304/2022_2023 : Supply and Installation of PCGI PUF filled panel for walkable ceiling panel having 50 mm thick (nominal) PUFF filled core, stud less (non-structural), non-progressive wall system for class 1000 and class 10000.The vertical joints in the panels are to be secured utilizing Aluminium batten strips/Vertical post powder coated matching with clean room wall system. All wall panels shall be double skin type having Aluminium skins (min. 0.8mm thick) on outer surfaces with Aluminium Honey Comb/PUFF Core with antistatic protection. All wall panels shall have Epoxy/PE finish in standard designer white colour. 50 mm thick PUFF panels shall be having return air risers as specified in drawing.The wall system must easily accommodate pipe, duct and tool penetration and doors while maintaining its air seal and structural integrity.The system must be capable of performing as a free-standing wall. The wall system is to be held in place, utilizing a gasketed head track (secured to the suspended ceiling) and gasketed floor track assembly.The height of wall system shall be 3.00m.All the framing members like head track, floor track, batten strips, corner posts, wall ends, vertical post etc. shall be made of extruded Aluminium in designer white finish matching wall panel system and complete as directed by Engineer In Charge.

300

-

-

... More
od314305/2022_2023 : Supply and Installation of PCGI PUF filled panel for wall and ceiling cladding having 50 mm thick (nominal) PUFF filled core, stud less (non-structural), non-progressive wall system for class 1000 and class 10000.The vertical joints in the panels are to be secured utilizing Aluminium batten strips/Vertical post powder coated matching with clean room wall system. All wall panels shall be double skin type having Aluminium skins (min. 0.8mm thick) on outer surfaces with Aluminium Honey Comb/PUFF Core with antistatic protection. All wall panels shall have Epoxy/PE finish in standard designer white colour. 50 mm thick PUFF panels shall be having return air risers as specified in drawing.The wall system must easily accommodate pipe, duct and tool penetration and doors while maintaining its air seal and structural integrity.The system must be capable of performing as a free-standing wall. The wall system is to be held in place, utilizing a gasketed head track (secured to the suspended ceiling) and gasketed floor track assembly.The height of wall system shall be 3.00m.All the framing members like head track, floor track, batten strips, corner posts, wall ends, vertical post etc. shall be made of extruded Aluminium in designer white finish matching wall panel system and complete as directed by Engineer In Charge.

1500

-

-

... More
od314306/2022_2023 : Supply and Installation of PCGI PUF filled high riser panel having 80 mm thick (nominal) PUFF filled core, stud less (non-structural), non-progressive wall system for class 1000 and class 10000 with inbuilt GI riser, vcd, 10 micron filter with aluminium powder coated perforated grills.The vertical joints in the panels are to be secured utilizing Aluminium batten strips/Vertical post powder coated matching with clean room wall system. All wall panels shall be double skin type having Aluminium skins (min. 0.8mm thick) on outer surfaces with Aluminium Honey Comb/PUFF Core with antistatic protection. All wall panels shall have Epoxy/PE finish in standard designer white colour. 80 mm thick PUFF panels shall be having return air risers as specified in drawing.The wall system must easily accommodate pipe, duct and tool penetration and doors while maintaining its air seal and structural integrity.The system must be capable of performing as a free-standing wall. The wall system is to be held in place, utilizing a gasketed head track (secured to the suspended ceiling) and gasketed floor track assembly.The height of wall system shall be 3.00m.All the framing members like head track, floor track, batten strips, corner posts, wall ends, vertical post etc. shall be made of extruded Aluminium in designer white finish matching wall panel system and complete as directed by Engineer In Charge.

150

-

-

... More
od314307/2022_2023 : Supply and Installation of PCGI PUF filled panel having 80 mm thick (nominal) PUFF filled core, stud less (non-structural), non-progressive wall system for class 1000 and class 10000.The vertical joints in the panels are to be secured utilizing Aluminium batten strips/Vertical post powder coated matching with clean room wall system. All wall panels shall be double skin type having Aluminium skins (min. 0.8mm thick) on outer surfaces with Aluminium Honey Comb/PUFF Core with antistatic protection. All wall panels shall have Epoxy/PE finish in standard designer white colour. 80 mm thick PUFF panels shall be having return air risers as specified in drawing.The wall system must easily accommodate pipe, duct and tool penetration and doors while maintaining its air seal and structural integrity.The system must be capable of performing as a free-standing wall. The wall system is to be held in place, utilizing a gasketed head track (secured to the suspended ceiling) and gasketed floor track assembly.The height of wall system shall be 3.00m.All the framing members like head track, floor track, batten strips, corner posts, wall ends, vertical post etc. shall be made of extruded Aluminium in designer white finish matching wall panel system and complete as directed by Engineer In Charge.

350

-

-

... More
od314308/2022_2023 : Supplying and Installation of ‘T’ bar type clean room ceiling system of size 600mm x 1200mm including arrangement for clamped filter fixing, white PVC gasket and adaptor for sprinkler and all other items required for installation as directed by Engineer in charge

775

-

-

... More
od314309/2022_2023 : Supply and Installation of walkable ceiling blank panels suitable for 600mm x 1200 mm ceiling grid with complete housing and other accessory for installation as directed by Engineer in charge.

625

-

-

... More
od314310/2022_2023 : Supply and installation of 50 mm thick (nominal) Aluminium Honeycomb core panel stud less (non-structural), non-progressive wall system for Class 100 Cleanroom. 50mm (nominal) thick, honeycomb, 3000 mm high stud less epoxy/PE roll coated aluminium clean room wall system complete with all the hardware items e.g., head track, floor track, vertical posts, wall ends, batten strips, white PVC gaskets, etc. required for installation all completeas directed by Engineer-in-Charge

170

-

-

... More
od314345/2022_2023 : Supply and installation of powder coated aluminum coving (R50) neatly complete as directed by engineer in charge

915

-

-

... More
od314346/2022_2023 : Supply and installation of powder coated aluminum corner coving neatly complete as directed by engineer in charge

70

-

-

... More
od314347/2022_2023 : Supply and laying coving of 3mm epoxy flooring neatly complete as directed by Engineer in charge

610

-

-

... More
od314348/2022_2023 : Supply and laying 3mm epoxy flooring neatly complete as directed by Engineer in charge

1000

-

-

... More
od314384/2022_2023 : Supply and installation of Air Curtain of size 1200 mm width complete as directed by engineer in charge

7

-

-

... More
od314920/2022_2023 : Charges for designing and commissioning of Clean rooms as per requirement and obtaining all statutory approvals required from various statutory bodies etc complete as per requirement for the running of Clean room

1

-

-

... More
19.6.4 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia R.C.C. pipe

10

-

-

... More
Joineries

-

-

-

... More
od315346/2022_2023 : Providing and fixing epoxy powder coated GI emergency semi glazed swing type single flush door of 1200 x 2100 mm size, complete with frames, emergency push bar lock, matching with clean room wall systems and all hardware as required including fixing white PVC gaskets to make door air tight, 6mm thick tempered clear glass and all other items required for installation.

5

-

-

... More
od315347/2022_2023 : Providing and fixing epoxy powder coated GI semi glazed swing type double flush door of 2000 x 2100 mm size, complete with frames, matching with clean room wall systems and all hardware as required including fixing white PVC gaskets to make door air tight, 6mm thick tempered clear glass and all other items required for installation.

6

-

-

... More
od315348/2022_2023 : Providing and fixing epoxy powder coated GI semi glazed swing type single flush door of 1200 x 2100 mm size, complete with frames, matching with clean room wall systems and all hardware as required including fixing white PVC gaskets to make door air tight, 6mm thick tempered clear glass and all other items required for installation.

10

-

-

... More
od315349/2022_2023 : Providing and fixing epoxy powder coated GI semi glazed swing type single flush door of 900 x 2100 mm size, complete with frames, matching with clean room wall systems and all hardware as required including fixing white PVC gaskets to make door air tight, 6mm thick tempered clear glass and all other items required for installation.

2

-

-

... More
od315350/2022_2023 : Providing and fixing epoxy powder coated GI semi glazed swing type single flush door of 700 x 2100 mm size, complete with frames, matching with clean room wall systems and all hardware as required including fixing white PVC gaskets to make door air tight, 6mm thick tempered clear glass and all other items required for installation.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.