Kerala State IT Infrastructure Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State IT Infrastructure Limited - KSITIL Tender

Works
Eprocure
Opening Date31 Oct 2020
Closing Date30 Nov 2020
Tender Amount₹ 30,91,879 
Notes
Download

Costs

Summary

Sitc Of Street Light And High Mast For Technocity Campus Pallippuram

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od2022/2020_2021 : Supply of 8m height Hot Dip Galvanized Octagonal Pole with top dia 70 mm, bottom dia 130 mm, sheet thickness 3mm, base plate of 200X200X12 mm size with 1000 mm long single arm bracket suitable for mounting one No's LED street light fixtures. The pole shall be installed on a 1:2:4 concrete plinth as per the detailed drawing. Providing separate adequate size PVC pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 16mm dia 450 mm length, projected bolt size length 80 mm pitch circle dia 200mm to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template. The threaded portion of foundation bolt protruded out side the plinth shall be galvanized. Terminal box with 6A SP MCB, neutral link, earth terminating facility and 16A, 4pole terminal block etc. shall be fixed inside the octagonal pole as required as per the tender specifications and approved list of makes.

13

-

-

... More
od2023/2020_2021 : Installation of item no.3

13

-

-

... More
od2041/2020_2021 : Supply, Installation, Testing & Commissioning of LED street light fittings with water proof, UV stabilized reinforced, plastic or treated plastic or toughened glass or Pressure die cast aluminum anticorrosive rust proof material housing with IP 65/66 degree of protection, clear polycarbonate diffuser, clear non-yellowing moulded PMMA lens, pole mounting clamps suitable for pole dia from 25-50mm, driver with Surge Protection and accessories pre-wired upto terminal block in control gear compartment, Operating voltage 140-270V, Color temperature: cool white. The system lumen efficacy shall be greater than 100 lumen/Watt. Luminaire shall have built-in tilt of 15 degree for reduction of bracket length. Luminaire shall have good thermal management system to limit the operating junction temperature of LED within the manufacturer’s recommendations. Luminaire shall have integral fins and central spine attached to LED mounting area for better heat dissipation. The luminaire system wattage should be 60 watts or less. Minimum burning hours should be greater than 45,000hrs. The driver should be universal electronic driver operating in the Voltage Range of 140V – 270 V, 50Hz AC. The driver should be equipped with surge protection (minimum 4.0kV). The operating Power factor shall be more than 0.95 (lag). The luminaire shall be equipped with coded mains receiver/ RF street light controller NEMA socket/M2M controller/ RF module for communicating with the CCMS control panel.

39

-

-

... More
od2042/2020_2021 : Installation, Testing & Commissioning of item no. 5

39

-

-

... More
od2043/2020_2021 : Supply of 12.5m high mast pole with its accessories. Mast shaft shall be in two sections suitable for wind velocity as per IS 875 part 3 with raising lowering system, luminaires carriage suitable to install 6 nos LED Flood Light in symmetrical/asymmetrical arrangement, double arm winch, 6 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lighting finial etc. complete. Including supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates, template, supply and installation of twin dome aviation obstruction light etc. complete as per the tender specifications and approved list of makes.

1

-

-

... More
od2044/2020_2021 : Installation, Testing & Commissioning of item no.7

1

-

-

... More
od2046/2020_2021 : Supply of LED Flood Light having system wattage less than 170W with C clamp mounting, Pressure die cast housing with High efficiency Glass cover , Ingress Protection-65, Driver Efficacy 90%, burning hours not less than 50000, Color temp : Cool white , Luminaire efficacy 100 lumen/Watt at system level with narrow beam, Heat dissipation / heat sink : well designed Thermal management system with PDC Aluminum heat sink, luminaire conform to IEC 60598. Provision for connectivity with CCMS to be provided.

6

-

-

... More
od2047/2020_2021 : Installation testing and commissioning of item no.9

6

-

-

... More
od2050/2020_2021 : Supply of IP65, dust and vermin proof, floor mounting type outdoor CCMS control panel fabricated using 1.8mm thick CRCA sheet steel, degreased, phospated and powder coated, the panel shall be fixed on the painted MS angles/ flats and C-channel base frame on the concrete plinth foundation. The panel incomer and outgoings as per the electrical scheme drawing (Rates as per item No. 15, 17 and 18). The panel should be capable of group light control with light dimming mechanism, coded mains transformer, coded mains transmitter or RF module with RF street light controller Nema sockets for communicating with street lights. Including Software, Mapping/ Programming, cloud server, data and AMC charges for 3 years as per detailed technical specifications, drawings, approved list of makes etc.

1

-

-

... More
od2051/2020_2021 : Installation testing and commissioning of item no.11

1

-

-

... More
od2059/2020_2021 : Supplying and fixing of 4-ways (4+12) double door (Metal door), suitable for surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer), as required.

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

3

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

3

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

16

-

-

... More
od2074/2020_2021 : Supply of the following sizes heavy duty PVC insulated and PVC sheathed/XLPE armoured power cable, conductors of best conductivity aluminium 1.1kV grade, conforming to IS:1554 (part I) 1964 for laying in cable trenches, masonry duct, GI/Hume pipes as applicable. 4Cx50sqmm A2XFY Cable

500

-

-

... More
od2082/2020_2021 : Supply of the following sizes heavy duty PVC insulated and PVC sheathed/XLPE armoured power cable, conductors of best conductivity aluminium 1.1kV grade, conforming to IS:1554 (part I) 1964 for laying in cable trenches, masonry duct, GI/Hume pipes as applicable. 4Cx10sqmm A2XFY Cable

280

-

-

... More
od2097/2020_2021 : Supply of the following sizes heavy duty PVC insulated and PVC sheathed/XLPE armoured power cable, conductors of best conductivity aluminium 1.1kV grade, conforming to IS:1554 (part I) 1964 for laying in cable trenches, masonry duct, GI/Hume pipes as applicable 4Cx6sqmm A2XFY Cable

50

-

-

... More
od2098/2020_2021 : Supply of the following sizes heavy duty PVC insulated and PVC sheathed/XLPE armoured power cable, conductors of best conductivity aluminium 1.1kV grade, conforming to IS:1554 (part I) 1964 for laying in cable trenches, masonry duct, GI/Hume pipes as applicable. 2Cx6sqmm A2XFY Cable

1900

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

250

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

45

-

-

... More
7.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

10

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

1100

-

-

... More
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm

95

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

500

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

40

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

535

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

90

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

40

-

-

... More
od2137/2020_2021 : Supply and laying of 3C x 1.5 sq.mm PVC Insulated and PVC sheathed Copper conductored stranded round flexible copper wire manufactured with bright annealed copper conductor, Insulated and sheathed with electrical grade PVC/XLPE as per IS 7098 (Part 1) 1988 with upto date amendments. (From terminal block to LED light fixture)

390

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

50

-

-

... More
9.1.36 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

4

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

52

-

-

... More
od2145/2020_2021 : Providing coil/spring earthing using 6SWG, GI wire for street light pole etc. GI wire buried to a minimum depth of 1.5m, with excavation, refilling and connecting GI wire to pole using bolt and nut complete.

26

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required

6

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earthelectrode, including connection/ termination with GI thimble etc. as required.

1500

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

50

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

20

-

-

... More
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

100

-

-

... More
od2154/2020_2021 : Supply and providing cast iron gully trap with covering at the top of the inspection chamber of earth pit as required 300 x 300 x 6 mm cast iron gully trap with covering.

6

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

45

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

15

-

-

... More
od2158/2020_2021 : Supplying and installation of 50mm dia. ISI marked, PVC conduit including bents, couplers etc. fixing while concreting of street light pole foundation for taking in and taking out cables to the street light pole,and making good the damages etc.

50

-

-

... More
od2159/2020_2021 : Supply and installation of hot dipped galvanized cable trays of the following sizes using suitable GI treaded rod suspenders, GI slotted ancle channels, with necessary bent, connectors etc. complete. (150x50x1.6)mm

30

-

-

... More
od2160/2020_2021 : Supply and installation of hot dipped galvanized cable trays of the following sizes using suitable GI treaded rod suspenders, GI slotted ancle channels, with necessary bent, connectors etc. complete.(300x50x1.6)mm

6

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

1

-

-

... More
od2161/2020_2021 : Supply, installation, testing and commissioning of 3-ph 4-wire class 0.5, Dual source energy meter with RS 485 port in sheet steel enclosure (3-pahse meter box) with terminal blocks, wiring, 6A SP MCB etc. Dual source energy meter L&T WC404021OOOO or equivalent.

1

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

1

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

1

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

15

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

10

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

10

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

50

-

-

... More
od2555/2020_2021 : Supply and fabrication using adequate size MS angles and flats for cable support, high mast feeder pillar support and others as per engineer-in-charge.

200

-

-

... More
od2164/2020_2021 : Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submission of Completion report, arranging inspection, getting sanction for energization of the installation from Electrical Inspectorate for commissioning of the street lights in the premises. Statutory payments will be reimbursed on production of the original receipts/ attested copies of original.

1

-

-

... More
CIVIL WORKS

-

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

50

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

43

-

-

... More
od2315/2020_2021 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m to 3m, as directed by Engineer-in-charge.

1.3

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

10

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

4.2

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

12.1

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

0.2

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

43

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

38.3

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

11.3

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

615

-

-

... More
85.101 : Supply of MS plates confirming to IS 2062GrB including cost of conveyance charges

10

-

-

... More
15.43.2 : Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

30

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.