Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala State Industrial Enterprises Limited - KSIE Tender
Civil And Construction
Civil Works Others
Transportation and Logistics
Eprocure
Opening Date5 Mar 2024
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 50,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KSIE_667294_1Bid Award Id
ViewTender No
CP-116/2023-24Tender Authority
Kerala State Industrial Enterprises Limited ViewPurchaser Address
-Website
http://http://www.ksie.net/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
9
-
-
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
32000
-
-
Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
5000
-
-
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet, roof
1055
-
-
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
190
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
35
-
-
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
50
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
20
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
9.5
-
-
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement : 6 coarse sand)
14
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
9.5
-
-
Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
80
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
950
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
500
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2000
-
-
Supply of Trapezoidal/ corrugated colour coated Galvalume sheet 0.50 mm thickness ,coated with alloy of Al.and Zn.Fixing of above sheets with necessary self drilling and self trapping screws/bolts and nuts. EPDM washers with 150 mm laps wherever required. The rates shall include cost of laps, fixers like S.D./ self trapping screws with EPDM washers incl. Stitching as required in complete line and level, incl.lifting to all height as required.
115
-
-
Relaying of departmentally supplied old Trapezoidal/ corrugated colour coated Galvalume sheet ,with necessary self drilling and self trapping screws/bolts and nuts. EPDM washers with 150 mm laps wherever required. The rates shall include cost of fixers like S.D./ self trapping screws with EPDM washers incl. Stitching as required in complete line and level, incl.lifting to all height as required.
100
-
-
Re-Fabrication and erection of departmentally supplied old Steel sections including cutting, hoisiting fixing in position and applying a priming coat of approved steel primer etc complete.
2000
-
-
Supply and fixing of PVC gutter at required slope, including all cost of clamps , other material and labour charges etc complete as directed by Engineer in charge
30
-
-
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete.
52
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand)
13
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
72.5
-
-
12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
725
-
-
12 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 ( 1 cement : 3 fine sand)
110
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
9.45
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
875
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
875
-
-
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
900
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
900
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.
70
-
-
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
15
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
84
-
-
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
350
-
-
Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately)
180
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portion- Powder coated aluminium (minimum thickness of powder coating 50 micron)
520
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
80
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge. Pre- laminated particle board with decorative lamination on both sides
146
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
80
-
-
Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
6
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
6
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete: (200x10 mm)
6
-
-
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
42
-
-
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.
20
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I. wire of dia 4 mm
40
-
-
Dismantling and Relaying of departmentally supplied Trapezoidall colour coated Galvalume sheet fencing ,with necessary self drilling and self trapping screws/bolts and nuts. EPDM washers with 150 mm laps wherever required. The rates shall include cost of fixers like S.D./ self trapping screws with EPDM washers incl.cost of MS post, struts etc (cost of earth work and concrete for fixing post to be paid for separately)
40
-
-
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
1
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
5
-
-
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern
4
-
-
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.White Agaria Marble Stone
1.5
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
6
-
-
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
6
-
-
Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931 15 mm nominal bore
30
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
70
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
180
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
50
-
-
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50
-
-
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
60
-
-
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
30
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
10
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
7
-
-
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow
4
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
6
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling
4
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
15
-
-
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
10
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
6
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
3
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
3
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee
3
-
-
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
4
-
-
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
5
-
-
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer
3
-
-
Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
6
-
-
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
5
-
-
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
6
-
-
Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
10
-
-
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
12
-
-
Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
3
-
-
Supplying and providing (12mm and 6mm river sand) 12mm premixed chipping carpet over B.T Surface with contractor's broken stone and river sand. After thoroughly cleaning the base with the brushes and applying a priming (5.0+5.0) Kg of Bitumen/10m2 and spreading the hot premix (formed of 0.027/m3 of contractor 12mm metal and 12.96 Kg of Bitumen per 10m2). Again rolling including the cost of bitumen, oil and fuel, hire of brass brooms, roller and other machines watching, lighting and other charges etc. complete (Total usage of Bitumen 31.60 Kg/10m2) inside covered godown.
713
-
-
Providing and laying WBM using 40 mm nominal size broken stone rolled to 75 thick with 8-10 T capacity power roller to proper gradients, lines and levels, voids filled with good quality red earth as blinding material including cost of all material, labour watering rolling etc., complete as directed by Engineer incharge.
150
-
-
Providing 50mm premixed bituminous macadam over WBM surface with contractor’s supplied metal 24mm, 12mm, 6mm after thoroughly cleaning the base with wire brushes, bas brooms and applying a priming coat of 5kg of bitumen/10m2 and spreading the hot premix (formed of 0.32m3 of 24mm metal and 0.22m3 of contractor’s 12mm metal and 24.08kg of bitumen/10m2) rolling the dense surface, then spreading the seal coat (compressing of hot premix of 0.09m3 of 6mm contractor’s metal and 8.64kg of bitumen per 10m2) again rolling including the cost of bitumen oil and fuel hire of brass brooms camber broad, rolling machines watching, lighting and other charges etc complete (total usage of bitumen is 37.72kg/10m2)
280
-
-
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder : Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
650
-
-
ELECTRICAL WORK
-
-
-
Point wiring in P.V.C conduit, with modular type switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
102
-
-
Twin control light point in P.V.C conduit, with modular type switch: Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2
-
-
Wiring in existing PVC conduit: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire
600
-
-
Wiring in existing PVC conduit: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
425
-
-
Wiring in existing PVC conduit: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq mm + 1 x 4 sq mm earth wire
425
-
-
S/L telephone cable: Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
100
-
-
S/F PVC Conduit: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
950
-
-
S/F PVC Conduit: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
400
-
-
S/F modular type switch/ socket : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
1
-
-
S/F modular type switch/ socket : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
1
-
-
S/F 2 module type electronic fan regulator : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
15
-
-
S/F modular type blanking plates : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
S/F modular boxes, base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)
16
-
-
S/F light plug point with modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
20
-
-
S/F 2x6A plug point with modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
20
-
-
S/F Power plug point with modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
11
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
102
-
-
S/F LED light fittings directly on ceiling/wall : Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required..
102
-
-
ITC ceiling fan : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
15
-
-
ITC Exhaust fan : Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
8
-
-
S/L of Cat 6 cable : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
325
-
-
S/L of Cat 6 cable : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
50
-
-
S/L of Cat 6 cable : Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable
50
-
-
S/F SPN MCB DB : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
1
-
-
S/F Horizontal TPN MCB DB : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4+12), Double door
2
-
-
S/F Vertical TPN MCB DB : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12), Double door
4
-
-
S/F Vertical TPN MCB DB : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4+24), Double door
1
-
-
S/F 'C' Series MCB : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Single pole
65
-
-
S/F 'C' Series MCB : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Three pole
8
-
-
S/F 'C' Series MCB : Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. Triple pole and neutral
2
-
-
S/F 2P MCB Isolator: Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with onnections, testing and commissioning etc. as required. 40 amps
1
-
-
S/F 4P MCB Isolator: Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with onnections, testing and commissioning etc. as required. 40 amps
4
-
-
S/F 4P MCB Isolator: Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with onnections, testing and commissioning etc. as required. 63 amps
1
-
-
S/F TPN RCCB : Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
4
-
-
SITC of SPN Industrial socket outlet: Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
12
-
-
S/F bare Cu wire for loop earth : Supply and land fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
280
-
-
S/F of L.T. XLPE cables on surface : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
150
-
-
S/F end termination of L.T. XLPE cables : Supply and making indoor end termination with single compression type cadmium plated brass cable glands, Aluminium lugs, for the following PVC sheathed / XLPE) aluminium conductor cable of 1.1KV grade as required 2C x 10 Sq.mm (19 mm)
4
-
-
S/F end termination of L.T. XLPE cables : Supply and making indoor end termination with single compression type cadmium plated brass cable glands, Aluminium lugs, for the following PVC sheathed / XLPE) aluminium conductor cable of 1.1KV grade as required 4C x 10 Sq.mm (25 mm)
8
-
-
S/F end termination of L.T. XLPE cables : Supply and making indoor end termination with single compression type cadmium plated brass cable glands, Aluminium lugs, for the following PVC sheathed / XLPE) aluminium conductor cable of 1.1KV grade as required 4C x 16 Sq.mm (38 mm)
4
-
-
S/F end termination of L.T. XLPE cables : Supply and making indoor end termination with single compression type cadmium plated brass cable glands, Aluminium lugs, for the following PVC sheathed / XLPE) aluminium conductor cable of 1.1KV grade as required 4C x 25 Sq.mm (38 mm)
2
-
-
S/F 12 mm steel 'S' type fan hook : Supply and providing 12 mm dia steel 'S' type fan hooks, on the RCC roof, making good the damages of roof etc. as required
15
-
-
S/F TPN Metal enclosure : Supply and fixing TPN sheet steel enclosure on surface/ recess along with provision for fixing one number TPN/ 4Pole, 415 V “C” curve MCB etc. as required.
2
-
-
Supply of 20W LED batten/ tube llight fittings : Supply and providing 20W Surface mounting type LED lenier batten/ tube light fittings with output of 2000 lumen, made out of CRCA body with white acrylic cover etc. as required.
55
-
-
Supply of 18/20 W surface/recess LED down lighter : Supply and providing 18/20 W low glare, recess mounting type, integral LED down light fittings with white powder coated Die cast aluminium body with anodised aluminium reflector etc.as required.
5
-
-
Supply of 7/8/9 W surface/recess LED down lighter : Supply and providing round shaped 7/8/9 W low glare, recess mounting type, integral LED down light fittings with white powder coated Die cast aluminium body with anodised aluminium reflector etc.as required.
5
-
-
Supply of 10W LED bulkhead luminaire : Supply and providing 10 W, LED bulkhead luminaire etc.as required.
8
-
-
S/F CAT 6 RJ 45 Computer Jack, Modular on existing box & plate: Supply and fixing modular type CAT 6 RJ 45 Computer Jack on existing modular box & cover plate and giving connections etc as required.
14
-
-
Supply of 1200mm Ceiling Fan : Supply of 1200 mm sweep 5 star rated Electric Ceiling Fan, White Colour, capacitor type with double ball bearing, shackles, 300 mm down rod, canopies, blades and resistance type regulator etc. suitable for operation on 220/ 240V, 50 Hz, single phase AC supply etc. as required.
15
-
-
Supply & fixing of 400mm wall Fan : Supplying and fixing 400 mm sweep wall fan with 3 speed positions with pulling cord and giving connections, testing & commissioning etc as required.
1
-
-
Supply of 305mm Exhaust Fan : Supply of 300/305 mm sweep light duty exhaust fan in metal frame suitable for operation on 220/ 240V, 50 Hz, single phase AC supply etc. as required.
1
-
-
Supply of 150mm Exhaust Fan : Supply of 150mm sweep Light Duty Exhaust fan in plastic body with self opening lowers, suitable for operation on 220/ 240V, 50 Hz, single phase AC supply etc. as required.
8
-
-
Supply of Al XLPE armoured power cable : Supply of following size heavy duty XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium, 1.1 KV grade, conforming to IS 7098 (part-I) etc, as required. 2C x 10 Sq.mm
30
-
-
Supply of Al XLPE armoured power cable : Supply of following size heavy duty XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium, 1.1 KV grade, conforming to IS 7098 (part-I) etc, as required. 4C x 10 Sq.mm
55
-
-
Supply of Al XLPE armoured power cable : Supply of following size heavy duty XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium, 1.1 KV grade, conforming to IS 7098 (part-I) etc, as required. 4C x 16 Sq.mm
55
-
-
Supply of Al XLPE armoured power cable : Supply of following size heavy duty XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium, 1.1 KV grade, conforming to IS 7098 (part-I) etc, as required. 4C x 25 Sq.mm
40
-
-
Existing 30KVA DG Set shifting & Installation,Commissioning and including required number of earthing,cable laying & glanding etc.rquired
1
-
-
Removing,existing light point,PVC conduit, DB & switch boards
1
-
-
DOCUMENTS & APPROVAL : Preparation of necessary forms, documents drawings etc. with necessary certifications & test reports and procuring approval and energisation certificate from Electrical Inspectorate & Kerala state Electricity Board, including all miscelaneous expenses and all related expences & formalities shall be met by contractor but excluding inspection & testing charges, statutory charges, Power allocation charges, cash deposit etc.
1
-
-