Kerala State Industrial Development Corporation Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 2,00,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KSIDC_534783_1Bid Award Id
ViewTender No
KSIDC/KUTTIYADI/2022-23/01Tender Authority
Kerala State Industrial Development Corporation ViewPurchaser Address
-Website
http://https://www.ksidc.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up
to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50
m outside the periphery of the area cleared
1000
-
-
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
13750
-
-
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
5
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
641.25
-
-
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
384.75
-
-
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
256.5
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
224.44
-
-
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
2244.38
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
336.66
-
-
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
1567.5
-
-
Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
313.5
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
48925
-
-
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available
size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and
above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete
2638.35
-
-
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
28671.5
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
28671.5
-
-
Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
28671.5
-
-
2 PART B - Main Entry Gate
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m.All kinds of soil
11.07
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.85
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size)
7.3
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth
and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level
excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :
3 graded stone aggregate 20 mm nominal size)
14
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
23.61
-
-
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers,
Abutments, Posts and Struts
53.55
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
165.31
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer all complete.
1850.52
-
-
Providing and fixing at site 4mm thick exterior grade Aluminium composit panels, 0.5mm coil thickness
,Panel size - as per design ( Gurind / Eurobound/ Alubond ) .The composit panel will be fixed to the tube
section by means of SS Screws . The joint will be sealed by using Whacker or dow corning silicon sealent
and weather sealent Elastras305, Dow corning789. The silicon shall be applied between the panels to
make it absolutely water tight with work.
25.92
-
-
Roofing with Aluminium powder coated tile profile 0.46mm thick including all materials and labour etc
complete.
11.99
-
-
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
53.55
-
-
Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28
ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
53.55
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade.
Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
75.6
-
-
Supply and fixing PVC with LED light display sign board by fixing on MS tube frame with required size
and shape. The area should be 3 meter wise and 2 meter height and each letter having 30 centimeter
height and 10 centimeter projection from surface. Fixing suitable cables and led light with color as per the
direction in charge
1
-
-
3 PART C - Bore Well
-
-
-
Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:
2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/
bore log, including hire & running charges of all equipments, tools plants & machineries required for the
job, all complete as per direction of Engineer - in- Charge, upto 90 metre depth below ground level.All
types of soil300 mm dia
90
-
-
Boring /drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:
2800 ( part I), including collecting samples from different strata, preparing and submitting strata chart/
bore, including hire & running charges of all equipments, tools, plants & machineries required for the job,
all complete as per direction of Engineer- in- charge, beyond 90 metre & upto 150 metre depth below
ground level.Rocky strata including Boulders300 mm dia
60
-
-
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium
well casing (CM) pipe of required dia, conforming to IS : 12818, including required hire and labour
charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer- in Charge.200 mm nominal size dia
150
-
-
4 PART D - Electrical
-
-
-
Providing and fixing 10HP Three Phase Submersible Pump, capacity 501-1000 LPM and 50Hz including
suitable 0 sq mm 4 core Copper Armoured Power Cable 200 meter length with required specification and
necessary starter, and pits paneeling works and positing in the borewell and connect 200 meter cable
complete as per the direction in charge
1
-
-
5 PART E - KSEB Connection
-
-
-
KSEB new connection licensing, documentation and all electrical panel board supply and wiring and all
work for 10HP power
1
-
-
6 PART F - Security Cabin Civil Works
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and
ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus
excavated soil as directed, within a lead of 50 m.All kinds of soil
22.76
-
-
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or
drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils
as directed, within a lead of 50 m.Ordinary rock
15.16
-
-
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked
materials.All kinds of soil
16.2
-
-
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked
materials.Ordinary or hard rock
3.6
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
2
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
2
-
-
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
3.14
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
250.74
-
-
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,
landings, balconies and access platform
13.54
-
-
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders bressumers and cantilevers
1.38
-
-
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in
floors and wallsUnder 20 cm wide
50.96
-
-
Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
1.35
-
-
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available
size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in CM 1:6 ( 1 cement : 6 coarse sand etc complete)
5.95
-
-
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement
concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth
level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
6.35
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and
shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints
with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
8.19
-
-
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water
absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in
skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
1.51
-
-
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine
cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,
approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area
of slab over 0.50 sqm
1.2
-
-
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing
to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite
work
3.2
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified
by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of
any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed
of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm,
including pointing in white cement mixed with pigment of matchingshade complete
8.46
-
-
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
20.49
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix:1:6 ( 1 cement : 6 fine sand)
72.99
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
93.47
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New
work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer
applied @ 2.20 kg/ 10 sqm)
49.84
-
-
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50
grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to
achieve even shade and colour.One coat
42.1
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium
(minimum thickness of powder coating 50 micron)
3.96
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making
provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket
required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder
coating 50 micron)
39.93
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood
particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows
shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural
drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination
on both sides
0.81
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50
mm thickness
5.18
-
-
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with
S.S. screws etc. complete as per direction of Engineer -in-Charge.Powder coated minimum thickness 50
micron aluminium tubular handle bar
2
-
-
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall
dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame
to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The
hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1
mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's
specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
5.2
-
-
Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles
and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt
edging on both sides. The styles and rails mitred and joint at the corners by means of M.S.
galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.
The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2
mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats.
The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having
over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at
two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers,
complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and
bathroom door shutter).
1.68
-
-
7 PART G - Security Cabin Electrical Works
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated
copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper
conductor single core cable etc as required.Group C
6
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5
sq.mm + 1x1.5 sq.mm earth wire
30
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
1
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess,
including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch,
connection etc. as required. (For light plugs to be used in non residentialbuildings).
2
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required
4
-
-
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all
types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5
sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
3
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength
(upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
1
-
-
Installation of exhaust fan in the existing opening, including making good the damage connection testing,
commissioning etc. as required.Upto 450 mm sweep
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6
way, Double door
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
4
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
1
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing
size direct in ground including excavation, sand cushioning, protective covering andrefilling the trench etc
as required.Upto 35 sq. mm
5
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing
size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of
following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
60
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
2
-
-
8 PART H - Security Cabin Sanitary Fittings
-
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat
and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and
making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat
and lid
1
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock,32 mm PTMT waste coupling
of standard pattern, including painting of fittingsand brackets, cutting and making good the walls
wherever required. WhiteVitreous China Flat back wash basin size 550x400 mm with single 15 mm
PTMTpillar cock.
1
-
-
Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore
1
-
-
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and
weighing not less than 810 gms.15 mm nominal bore
2
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing
of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal
outer dia pipes
15
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of
cutting chases and making good the same including testing of joints complete as per direction of
Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm
nominal outer dia pipes
16
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of
cutting chases and making good the same including testing of joints complete as per direction of
Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm
nominal outer dia pipes
15
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
2000
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm
nominal bore
1
-
-
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats
complete:25 mm nominal bore
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements