Kerala State Housing Board Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Housing Board - KSHB Tender

Works
Eprocure
Opening Date25 Jul 2020
Closing Date17 Aug 2020
Tender Amount₹ 61,75,674 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point

109

-

-

... More
90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point

271

-

-

... More
90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points

112

-

-

... More
90.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point

18

-

-

... More
90.3.17.1 : Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe

20

-

-

... More
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

400

-

-

... More
90.3.20.3 : Supply & installation of light fittings on TW round block br Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture

8

-

-

... More
90.3.21.3 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket br Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture

8

-

-

... More
90.3.22.3 : Supply & installation of light fittings on flat iron bracket br Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture

8

-

-

... More
90.3.23.3 : Supply & installation of fittings suspended on steel chain br Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet .5mm thick with all accessories and lamps etc. suspended from ceiling using 2 nos steel chain (16 SWG or nearest available size) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200mm 1X20W LED Lamp with box type fixture

8

-

-

... More
90.3.24.3 : Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod br Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture

8

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

271

-

-

... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C

271

-

-

... More
90.6.5.9 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm

5

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

250

-

-

... More
1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm

30

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

800

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

100

-

-

... More
90.6.9.2 : Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair

100

-

-

... More
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

6

-

-

... More
90.10.3.17 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket

349

-

-

... More
90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

6

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

16

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

6

-

-

... More
90.1.1.1 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm

280

-

-

... More
90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm

50

-

-

... More
1.21.5 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm

20

-

-

... More
90.12.1.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm

20

-

-

... More
90.12.1.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm

15

-

-

... More
90.12.1.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm

10

-

-

... More
90.12.1.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm

5

-

-

... More
90.12.1.27 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 25 sq mm

5

-

-

... More
90.12.1.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 35 sq mm

10

-

-

... More
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm

5

-

-

... More
90.12.1.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 70 sq mm

5

-

-

... More
90.12.1.31 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 95 sq mm

5

-

-

... More
90.12.1.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm

10

-

-

... More
90.12.1.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm

5

-

-

... More
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm

30

-

-

... More
90.12.1.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm

5

-

-

... More
90.12.5.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm

6

-

-

... More
90.12.5.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm

6

-

-

... More
90.12.5.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm

12

-

-

... More
90.12.5.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm

6

-

-

... More
90.12.5.27 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 25 sq mm

5

-

-

... More
90.12.5.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm

5

-

-

... More
90.12.5.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm

10

-

-

... More
90.12.5.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm

5

-

-

... More
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm

10

-

-

... More
90.12.5.31 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 95 sq mm

5

-

-

... More
90.12.5.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm

5

-

-

... More
90.12.5.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm

12

-

-

... More
90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm

10

-

-

... More
90.12.6.1 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 4 sq mm

5

-

-

... More
90.12.6.2 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 6 sq mm

5

-

-

... More
90.12.6.3 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm

60

-

-

... More
90.12.6.13 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 6 sq mm

15

-

-

... More
90.12.6.27 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 25 sq mm

5

-

-

... More
90.12.6.28 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm

5

-

-

... More
90.12.6.29 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm

5

-

-

... More
90.12.6.30 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm

5

-

-

... More
90.12.6.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 95 sq mm

5

-

-

... More
90.12.6.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm

10

-

-

... More
90.12.40.32 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 6 sq mm

5

-

-

... More
90.12.6.40 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm

60

-

-

... More
90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm

10

-

-

... More
90.12.7.1 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp

50

-

-

... More
90.12.7.2 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

50

-

-

... More
90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

280

-

-

... More
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

10

-

-

... More
90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp

5

-

-

... More
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

35

-

-

... More
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

30

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

5

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

5

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

25

-

-

... More
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

10

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

400

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

235

-

-

... More
90.12.24.2 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm

16

-

-

... More
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm

16

-

-

... More
90.12.24.4 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm

54

-

-

... More
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm

42

-

-

... More
90.12.24.6 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm

12

-

-

... More
90.12.24.7 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm

12

-

-

... More
90.12.24.8 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.50 sq mm

12

-

-

... More
90.12.24.9 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.70 sq mm

4

-

-

... More
90.12.24.10 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.95 sq mm

4

-

-

... More
90.12.24.13 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.185 sq mm

6

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

980

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

20

-

-

... More
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm

15

-

-

... More
1.22.1 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep

10

-

-

... More
1.22.2 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.100 mm X 100 mm X 60 mm deep

6

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

2

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

12

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

45

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

111

-

-

... More
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)

1

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

5

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

870

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

5

-

-

... More
1.53.2 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable

5

-

-

... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.

114

-

-

... More
2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N

18

-

-

... More
2.1.4 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N

12

-

-

... More
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

2

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

10

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

8

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

266

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

11

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

5

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

19

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

19

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

17

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

20

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB

2

-

-

... More
2.23.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB

10

-

-

... More
2.23.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 10 way, Double door SPN MCBDB

8

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

16

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

10

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

20

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

50

-

-

... More
5.10 : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

40

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

20

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

40

-

-

... More
6.2 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.

5

-

-

... More
6.4 : Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

200

-

-

... More
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.

5

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

15

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

8

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

36

-

-

... More
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

2

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

10

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

4

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
10.4.2 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:120 sq. mm

1

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

1

-

-

... More
10.5.2 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :120 sq. mm

1

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

5

-

-

... More
14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.

5

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

6

-

-

... More
14.13.2 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required80 mm dia

6

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

6

-

-

... More
od89658/2020_2021 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS). 9 module metal box in recess.

36

-

-

... More
od89659/2020_2021 : S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the following ratings: 125A, AC 23 A, 4 pole on-load COS

1

-

-

... More
od89660/2020_2021 : Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS) 9 module white/ off-white.

9

-

-

... More
od89661/2020_2021 : Supply and fixing 45 W LED street light fittings on existing street light pole and giving connection with suitable length of 3 core round flex PVC insulated and PVC sheathed wire.

2

-

-

... More
od89662/2020_2021 : Supply and fixing suitable size sintex type box front opening lockable type on 100mm GI pipe firmly with necessary holes for cable glanding height preferably 1 mts from ground level.

2

-

-

... More
od89663/2020_2021 : Supply and fixing of 100mm hot galvanized B class GI pie of length 2.5 mtr above ground / platform level on which 75mm dia B class GI pipe to form telescopic type welded joint firmly for a height of 2 mts and 32/40mm GI pipe B class jointed in such a way that it is bend to shape to project the road up to 1 mtr ( suitably) for fixing 1x 45 Watts LED street light fittings. The base of 100mm pipe is welded jointed with suitable GI plate with holes at the four corners for bottom base plate with minimum 5mm gap at the pipe. Including supply and fixing suitable heavy duty foundation bolts, base plate, formation of foundation, etc complete for holding the pole in vertical position. Necessary holes an clamp shall be provided in the pipe for fixing of sindex type box for accommodating control of the light. The pipe should be painted with two coats of good quality aluminum paint over a coat of sinchromate primer coat.

2

-

-

... More
od89664/2020_2021 : Supply, conveyance, installation, testing and commissioning of 305 mm single phase heavy duty 1400 rpm exhaust fan in metal frame in the existing opening, fixing necessary bolts and nuts, making good the damages etc as required including giving connections with required length of 24/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

20

-

-

... More
od89665/2020_2021 : Supply, conveyance, installation, testing and commissioning of 300/305 mm single phase light duty exhaust fan in metal frame in the existing opening, fixing necessary bolts and nuts, making good the damages etc as required including giving connections with required length of 24/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.

2

-

-

... More
od89666/2020_2021 : Charges for the preparation of schematic drawings of all wiring & circuits, cable routs, etc and the same laminated and installed near the meter board.including charges for the preparation of completion certificate produced to the KSEB for obtain connection as per KSEB norms.

1

-

-

... More
od89667/2020_2021 : Charges for colour washing two coats of suitable colour mach to the near by surface.

30

-

-

... More
od89668/2020_2021 : Form works for reinforced cement concrete in slabs including wooden panels, joists, bamboo post, and labour for taking for taking down after completion of works (Hire & Labour charges only)

10

-

-

... More
od89669/2020_2021 : Charges for cutting holes suitable accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing, etc as required.

22

-

-

... More
od89670/2020_2021 : Supply and installation of suitable size MS rod type fan clamp hanging on existing roof reinforcement after chipping existing RCC slab and re plastering colour washing the damaged surface in good condition as matching to the near by surface etc as required.

15

-

-

... More
od89671/2020_2021 : Supply and fixing 75x75x3mm size round / square of phenolic laminated sheet as front cover to the existing box.

10

-

-

... More
od89672/2020_2021 : Supply and fixing 20mm normal size one way terminal junction box conforming to IS 3419/1988 along with the PVC conduits laid in concrete.

271

-

-

... More
od89673/2020_2021 : Supply and fixing 63A, AC 23A, 4 pole on load COS on existing panel assembly / angle iron frame work.

1

-

-

... More
od89674/2020_2021 : Supply and providing 9 Lr capacity GI fre bucket painted in post office red with primer coat of red oxide and written with white paint as "FIRE" mounted on ms angle frame work / wall bracket filled with fine sand, painting the bracket / floor stand including making good the damages, colour washing etc as required.

6

-

-

... More
od89675/2020_2021 : Supply and providing 5Kg or nearest size ISI branded dry chemical powder type fire extinguisher with hose and clamps including fixing it to wall as required.

13

-

-

... More
od89676/2020_2021 : Supply and providing ms chequered plate of suitable thickness including cutting, welding, painting, etc as required.

50

-

-

... More
od89677/2020_2021 : Supply and providing 2mm thick elstromeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3KVdieelectric strength.

5

-

-

... More
od89678/2020_2021 : Supply and fixing 100x100x3 mm phenolic laminated sheet as front cover to the existing box

10

-

-

... More
od89679/2020_2021 : Supply and providing 8 to 10 W LED power rated lamp in the existing fittings as required.

109

-

-

... More
od89680/2020_2021 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W CFL to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface as required.

6

-

-

... More
od89681/2020_2021 : Supply and providing 25x8 mm GI bolt & nut with washers on the existing box/ earth bus etc as required including drilling necessary holes as required.

88

-

-

... More
od89682/2020_2021 : Supply and providing 25x6 mm GI bolt & nut with washers on the existing box/ earth bus etc as required including drilling necessary holes as required.

300

-

-

... More
od89683/2020_2021 : Supply, threading, laying, jointing & clamping of 40 mm dia size PVC pipe (8kgf/cm2) with all required accessories and clamp including cutting and making good the walls, colour washing, etc on surface of wall / parapet etc as required.

10

-

-

... More
od89684/2020_2021 : Supply, threading, laying, jointing & clamping of 32 mm dia size PVC pipe (8kgf/cm2) with all required accessories and clamp including cutting and making good the walls, colour washing, etc on surface of wall / parapet etc as required.

10

-

-

... More
od89685/2020_2021 : Supplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthing system as required.20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm

4

-

-

... More
od89686/2020_2021 : Supplying and providing earth clamps for siemen's / tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for 25 - 95 sq. mm with 20 mm wide x 1.2 mm thick clip of cables as required.

16

-

-

... More
od89687/2020_2021 : Supplying and providing earth clamps for siemen's / tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for 4 - 16 sq. mm with 12 mm wide x 1 mm thick clip of cables as required.

62

-

-

... More
od89688/2020_2021 : Supply and clamping 50 mm dia PVC on wall with required accessories including cutting and making good the walls, colour washing etc as required as protective covering to cables.

10

-

-

... More
od89689/2020_2021 : Supply and fixing 32 A, 415 V 2 way neutral ;ink mounted on DMC / SME base.

1

-

-

... More
od89690/2020_2021 : Supply and fixing 32 A, 415 V DIN type fuse base.

3

-

-

... More
od89691/2020_2021 : Supply of superior quality copper earth socket of 3.15 mm (10 SWG) earth conductor including crimping etc as required.

150

-

-

... More
od89692/2020_2021 : Supply of superior quality copper earth socket of 2.00 mm (14 SWG) earth conductor including crimping etc as required.

200

-

-

... More
od89693/2020_2021 : Supply and drawing 3.15 mm (10 SWG) bare copper earthing conductor laid 0.6 M below ground level including exavating trench of suitable size and re filling etc as required.

50

-

-

... More
od89694/2020_2021 : Supply and drawing 3.15 mm (10 SWG) bare copper earthing conductor along with wiring / cables and giving connection as required.

600

-

-

... More
od89695/2020_2021 : <br>Supply and drawing 2.65 mm bare copper earthing conductor along with wiring/cables and giving connection as required.

100

-

-

... More
od89696/2020_2021 : Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for vertical run). 25 x 6 mm GI strip

100

-

-

... More
od89697/2020_2021 : Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for horizontal run). 25 x 6 mm GI strip

200

-

-

... More
od89698/2020_2021 : Supplying, threading, laying, jointing & clamping of the following sizes of PVC pipe (8 Kgf/ cm2) with all required accessories and clamp including cutting and making good the walls, colour washing etc. on surface of wall / parapet etc. as required. 40 mm dia

10

-

-

... More
od89699/2020_2021 : Supplying, threading, laying, jointing & clamping of the following sizes of PVC pipe (8 Kgf/ cm2) with all required accessories and clamp including cutting and making good the walls, colour washing etc. on surface of wall / parapet etc. as required. 32 mm dia

10

-

-

... More
od89700/2020_2021 : Providing and fixing testing joint made of 2 no. strips as mentioned below of the following sizes provided on either side of the conductors with 4 nos of GI bolts, nuts check nuts and spring washers etc. complete as required (for down conductors). 2 Nos 25 x 6 mm copper strip 150mm long

5

-

-

... More
od89701/2020_2021 : Supply and providing suitable light roofing on the Dry type out door transformer by using suitable size zinc aluminium sheet, GI holllow sections, 'B' class GI pipe minimum 40mm size as pole. The roofing horizontally extended out side the transformer around minimum 60cm. painting the GI hollow section and GI pipe by using good quality enamal paint of colour to suit the transformer over a coat of zinchromate primer.

1

-

-

... More
od89702/2020_2021 : Supply and providing suitable femcing around the DG set with gate 1000 mm wide by using 8 SWG GI weld mesh weld with suitable angle iron frame work & 40mm GI 'B' class pipe as pole and painting two coats of good quality enamel paint over a coat of zinchromate primer.

1

-

-

... More
od89703/2020_2021 : Supply and providing suitable femcing around the transformer with gate 1000 mm wide by using 8 SWG GI weld mesh weld with suitable angle iron frame work & 40mm GI 'B' class pipe as pole and painting two coats of goodquolity enamal paint over a coatof red oxide primer.

1

-

-

... More
od89704/2020_2021 : Supply, installation, testing and commissioning of 2 number 5 HP mono block cetrifugal pump and motor set with all standard accessories fixed in the pump room after making required foundatin, nut & bolt, etc as per site condition and giving all electrcal connection with double earthing by using required copper conductor. Including supply and fixing GM/ brass ISI brands of suitable size 2no NRV, 4no wheel valve, 2no foot valve, cost of suction and delivery lines up to bottom of the plumbing duct by using requird quantity of suitable size heavy duty HD PVC pipe as per site condition and direction of departmental officers. Make Kirlosker/ cormpton.

2

-

-

... More
od89705/2020_2021 : Supply and laying medium gauge PVC conduit conforming to IS 9537/1983 Part III n roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-reinforcement/ existing duct etc. as required. 25mm dia

30

-

-

... More
od89706/2020_2021 : Supply and drawing PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq. mm

30

-

-

... More
od89707/2020_2021 : Supply, erection, testing and commissioning of 2 HP open well submersible pump kirloskar KOSN 225 or equivalent model 50x40mm, single phase, 9 to 28 mtr head, 318 to 132 LPM discharge flow range, SS motor body, CI impeller with L&T MR-G2 or equivalent make 2 HP single phase bore well pump controller, etc complete and giving connection and made functional

1

-

-

... More
od89708/2020_2021 : Supply and installation of emergency push button station near by the transformer room.

1

-

-

... More
od89709/2020_2021 : Supply of electrical 15 kv grade 15" long rubber hand gloves suitable for operation of switch gear.

2

-

-

... More
od89710/2020_2021 : Supply and installation of LED aviation obstruction lamp on the top of the building including providing suitable GI pipe for fixing the same.

1

-

-

... More
od89711/2020_2021 : Supply and installation laminated all Electrical Inspectorate final approved drawings with copy of final energisation sanction order on the wall of power house.

2

-

-

... More
od89712/2020_2021 : Supplying, fixing and jointing together 100 mm / nearest suitable higher size using exhaust pie for125 KVA DG set 'B' class GI pipe bearing ISI mark with all accessories on wall/ ducts with necessary clamps, cutting masonry & concrete walls etc through the duct or under the ceiling including cost & conveyance of all materials and specials to the site and labour charges including hire & labour for scaffolding etc complete for all floors.

25

-

-

... More
od89713/2020_2021 : Installation, testing and commissioning of 125 KVA acoustic covered DG set with all accessories giving all incoming and out going connections as per IE rule and KSEB standards. Including unloading charges and formation of suitable foundation, fuel line with control tap, drain arrangements, etc.

1

-

-

... More
od89714/2020_2021 : Installation, testing, commissioning of outdoor Transformer 200KVA dry type (Cast Resin) on suitable MS angle on suitable MS angle / channel embedded in floor including tsting, connecting HT& LT side cable connection, etc. complete as per the Eelctrical Inspectorate & KSEB rules. Including charges for the formation of suitable size foundation for installing the transformer, unloading cahrges, etc. as per the requirement of EI & KSEB.

1

-

-

... More
od89715/2020_2021 : Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.

10

-

-

... More
od89716/2020_2021 : Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern fittings of all types (excluding excavation & concrete base) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required. 32 mm dia

5

-

-

... More
od89717/2020_2021 : Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

5

-

-

... More
od89718/2020_2021 : Supply, conveyance, installation, testing and commissioning of Single/double sided LED floor indication (GF to 7th floor) signage with built in battery back up.fittings of all types directly on wall and giving connection etc as required

6

-

-

... More
od89719/2020_2021 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

2

-

-

... More
od89720/2020_2021 : Supply and fixing 3 phase, 3 wire, 110 V ( L-L), -/1 A CT or -/5A CT with RS 485 port of class 0

1

-

-

... More
od89721/2020_2021 : Supply and fixing 200/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5

3

-

-

... More
od89722/2020_2021 : Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.

100

-

-

... More
od89723/2020_2021 : Supplying and installation of supports, anchor bolts etc made out of suitable size single section MS angle, flats etc as required including painting with 2 coats of synthetic enamel paint.

750

-

-

... More
od89724/2020_2021 : Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height

250

-

-

... More
od89725/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 7.5 HP 3 Ph DOL starter

2

-

-

... More
od89726/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 2 -80A, DIN type fuse link of size 000

60

-

-

... More
od89727/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 6 A-100A DIN type fuse link of size 00

24

-

-

... More
od89728/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 40 A, 10 kA, TP MCB (C curve)

2

-

-

... More
od89729/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required. 40 A, 4 pole, 300 mA RCCB

2

-

-

... More
od89730/2020_2021 : Supply, conveyance and fixing the following typ. es & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch

2

-

-

... More
od89731/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required, 32 A, 415 V, 50 Hz, AC 23 A duty, SPN SDF for DIN fuse<br>

6

-

-

... More
od89732/2020_2021 : Supply, conveyance and fixing the following types & current rated control gears & switch gears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 250 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with thermal setting of 50 - 100% having adjustable OL & SC

1

-

-

... More
od89733/2020_2021 : Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. 4 sq mm

8

-

-

... More
od89734/2020_2021 : Supply, laying and clamping of 1 no. 11 KV grade XLPE cable of the following sizes using clamps fabricated from 20 x 3 mm MS flat, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 3c 150 sqmm

10

-

-

... More
od89735/2020_2021 : Supply, laying and clamping of 1 no. 11 KV grade XLPE cable of the following sizes using clamps fabricated from 20 x 3 mm MS flat, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 3 core 300 sq mm

10

-

-

... More
od89736/2020_2021 : Supply & laying of one No. 11 KV grade XLPE cable of the following sizes in the existing masonry open duct as required. 3c 150 sqmm.

10

-

-

... More
od89737/2020_2021 : Supply & laying of one No. 11 KV grade XLPE cable of the following sizes in the existing masonry open duct as required. 3c 300sqmm

10

-

-

... More
od89738/2020_2021 : Supply & laying of one number 11 KV grade XLPE cable of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3c 150 sqmm

5

-

-

... More
od89739/2020_2021 : Supply & laying of one number 11 KV grade XLPE cable of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3c 300 sq mm

5

-

-

... More
od89740/2020_2021 : Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). 20 x 3 mm copper strip tinned at the points of contacts

50

-

-

... More
od89741/2020_2021 : Supply and laying strips of the following sizes along with wiring/ cables and giving connection as required. 20 x 3 mm copper strip tinned at the points of contacts eart conductor to duct.

150

-

-

... More
od89742/2020_2021 : Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 x 3 mm copper strip tinned at the points of contacts

20

-

-

... More
od89743/2020_2021 : Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip

2.4

-

-

... More
od89744/2020_2021 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 40 A, 10 kA, DP MCB (C curve)

5

-

-

... More
od89745/2020_2021 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B) 6/16 A socket

40

-

-

... More
od89746/2020_2021 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B) Blank plate 1 M

15

-

-

... More
od89747/2020_2021 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B) 16 A SP 1 way switch

40

-

-

... More
od89748/2020_2021 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B) 6 A SP 1 way switch

354

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)

20

-

-

... More
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

10.3

-

-

... More
90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet

10

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

15

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

2500

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

1080

-

-

... More
od89749/2020_2021 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.00 sq mm single run with required sockets.

50

-

-

... More
od89750/2020_2021 : Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 2.50 sq mm single run with required sockets.

50

-

-

... More
od89751/2020_2021 : LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour

2

-

-

... More
od89752/2020_2021 : Supply and fixing LED indicators for all voltage ranges - Blue Colour

1

-

-

... More
od89753/2020_2021 : Supply and fixing three phase multi function meters to read V, A and F, accuracy class 0.5

1

-

-

... More
od89754/2020_2021 : supply of superior quality copper socket for the following sizes of conductor including crimping etc. as required. 4.00 mm (8 SWG)

75

-

-

... More
od89755/2020_2021 : Supply and laying strips of the following sizes for panel board earthing and giving connection as required. 20 x 3 mm copper strip tinned at the points of contacts

5

-

-

... More
od89756/2020_2021 : Supply and drawing bare conductors of the following sizes along with wiring/ cables and giving connection as required.4.00 mm copper conductor (8 SWG)

10

-

-

... More
od89757/2020_2021 : Supply and fixing 4mm copper bare conductor with heat shrinking sleeve

10

-

-

... More
od89758/2020_2021 : Supply of Outdoor Transformer 200 KVA dry type with all standard accessories complete as per the Electrical Inspectorate & KSEB rules. TECHNICAL PARTICULARS<br>200 KVA USS(Outdoor Type) Consists of (1) Cast Resin Transformer. Reference Standards IS 2026/IS 11171, Type & Make of Transformer UNIPOWER/ KEL/Equivalent make Cast Resin Dry Type, Normal continuous Rating (KVA) 315, Voltage Ratio 11 kV/433 V, Rated Frequency 50 Hz, Number of Phases 3, Type of Cooling AN(Air Natural), Vector Group Dyn 11, Connections ( HV / LV) Delta / Star, Winding Material Copper, Type of Tap changer Off- Circuit Tap Links, Trappings on HV side +5% to -5% in steps of 2.5%, Class of insulation Class F, Lamination CRGO (M-4 Grade), Reference Ambient Temperature 50°C, Temperature rise of wingdings above ambient 90°C, Insulation level<br>a) Impulse withstand voltage (HV)<br>b) Power frequency withstand voltage (HV/LV)<br>75 kV ( Peak), kV (rms) / 3 kV (rms), Terminal Arrangement (HV/ LV) Provision for coupling 11 KV HT panel / Cable Box, Type of Installation Outdoor<br>Fittings  Lifting lugs, Temperature Indicator,Rating and Diagram Plate, Earthing Terminals, Enclosure – IP54, Transformer losses will be strictly as per Energy conservation Building codes(ECBC norms). Inclusive of all taxes and duties, loading and unloading and conveyance charges up to site. (2) 11KV LBS Panel (With HT metering) suitable for 315 KVA CRT, Reference Standards IS 9920, Type Air Break, Manual Front operated, Duty Load Breaking, Fault Making, Voltage 11 kV,3Φ,50 Hz., Rated Current 630 A, Fault level 25 kA, Fault withstand time 3 seconds, Operating Handle Yes, Mechanical Trip push button, etcv. complete. Electrical Trip push button, Trip Coil Voltage 230 V AC, ON / OFF Indicator, Earth Switch Yes, Interlock Between SFU & Earth switch, HRC fuse link 3 NOS, Space heater & Thermostat Current Transformer 3 Nos.( ---/5 A, 10VA, Class 0.2S)<br>Potential Transformer 1 No. (11kV/110 V,20 VA, Class 0.2), Control Wiring with appropriate colors as Lot, 250 A 4 P MCCB provided at seceondary side of the transformer aith all statutary accessofries for the approval of EI& KSEB. Provision for receiving incoming and outgoing cable Through bottom entry, Provision for TOD Meter (TOD meter not included in our scope of supply), Separate chamber for CT, PT, TOD Meter, Test Terminal Block with fuse 1 set, KSEB sealing provision provided in the enclosure, Enclosure Powder Coated. Inclusive of all taxes and duties, loading and unloading and conveyance charges up to site.

1

-

-

... More
od89759/2020_2021 : Provision for statutory fee (like Schematic approval fee, Testing of TriVector meter /CT/Multi Function meter etc as required ) at Kerala State Electricity Licensing Board -Amount will be reimbursed after submitting original document/receipt

1

-

-

... More
od89760/2020_2021 : Preparation of 3 set of Electric schematic drawing as per Electrical Inspectorate & KSEB rules and get Approval from Electrical Inspectorate concerned , one set of Approved schematic shall be laminated with good quality laminated paper and the same shall be fixed as directed by Engineer in charge <br>(Rate for each set ) Except statutory fee at Electrical inspectorate

6

-

-

... More
od89761/2020_2021 : Supply, installation, testing and commissioning of 125 KVA AMF silent DG set with CPCB II approved acoustic enclosure and anti vibration pads as per CPCB norms comprising of Cummins Make –Model No C125D5P or suitable equivalent model radiator cooled diesel engine developing 125/100 BHP at 1500 RPM or suitable nearest BHP/RPM complete with standard accessories coupled to stamford /KEL / equivalent alternator rated at 125 KVA at 415 volts, mounted on channel iron base frame complete with fuel tank of 8 hour running or 290 Lr / suitable nearest capacity, standard manual / electronic control panel and 1 no 12 volt battery with lead wire terminals anti vibration mounting pads etc as per electrical inspectorate approval. Including loading and unloading charges and all duties and taxes and including cost for extending exhaust pipe up to the roof top of DG set building by using B class GI/MS pipe of suitable size formation of foundation and installation. Including providing emergency push button. etc complete.<br>Technical Data Latest Technology and unmatched Performance, Environment Friendly Power, Lowest operating cost& comprehensive warranty, single source power assurance,<br>Engine -Technical Data Generator Set Specification Model C125D5P Duty Prime Prime Power Rating kVA / kWe 125 No. of Phases 3 Phase 1 Phase Output Voltage (V) 415 V 230 V Power Factor 0.8 (lagging) 0.8 (lagging) Current (3 phase/ 1 phase) (A) 70 217 Frequency (Hz) and RPM 50 Hz, 1500 RPM Engine Specification Make Cummins Model 6BTAA5.9-G13 MoEF Certified Power (hp) 84 Required Power for Rated kVA (hp) 66 Cooling Liquid Cooled (EG Complete 50:50) Aspiration -Turbocharged, Charge Air Cooled No. of cylinders 4 Bore (mm) x Stroke (mm) 95 x 115 Compression ratio 19:1 Displacement (litre) 3.3 Fuel High Speed Diesel Fuel consumption @75% load with radiator and fan* (litre/hr) 9.6 110.15 Fuel consumption @100% load with radiator and fan* (litre/hr) 12.44 13.28 Performance class of generator set ISO 8528-5 G2 Starting system 12 V DC Electrical Lube oil specification CI4+ 15W40 Lube oil sump capacity, High-Low level (litre) 7 - 5.5 Total lubrication system capacity (litre) 7.9 Lube oil consumption @ full load** (litre/hr) 0.01 Total coolant capacity (litre) 13 Exhaust pipe size (inch) 3 Total wet weight (Engine +Radiator) (kg) 375 Length x Width x Height (Engine) (mm) 1066 x 725 x 1033 Mean piston speed (m/s) 5.75 Combustion air intake @100% load (±5%) (cfm) 160 Exhaust Temperature (°C) 490 <br> Alternator Specification - Make Alternator frame Enclosure Voltage regulation (Max.) Class of Insulation Winding Pitch Stator Winding Rotor Waveform distortion/ Total Harmonic Distortion Maximum Unbalanced Load across phases# Telephonic Harmonic factor Stamford (CGT) UCI224D UCI224G IP23 ±1% H Class 2/3 Double layer lap Dynamically Balanced No load < 1.5 %, Non distorting balanced linear load < 5 % less than or equal to 25% < 2%<br>

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.