Kerala State Housing Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Housing Board - KSHB Tender

Works
Eprocure
Opening Date29 Jun 2020
Closing Date15 Jul 2020
Tender Amount₹ 54,18,679 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
90.1.1.3 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.

350

-

-

... More
od215863/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.<br>Group A

125

-

-

... More
od215864/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).<br>Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point

12

-

-

... More
od215865/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Single control light point without ceiling rose - Short point

100

-

-

... More
od215866/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Twin Control light point with 6A, plate ceiling rose - Short point

11

-

-

... More
od215867/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Single Control light point with 6A, plate ceiling rose - Short point

230

-

-

... More
od215868/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).<br>Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point

125

-

-

... More
od215869/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Independent plug <br>Group A

60

-

-

... More
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A

5

-

-

... More
LED TUBE &,LED SURFACE PANEL

-

-

-

... More
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required

160

-

-

... More
od138235/2019_2020 : Supply, conveyance installation testing and commissioning of pre-wired light 8W to 10Ws LED strip type fittings (ordinary type LED light fittings)complete with all accessories and lamps etc. directly on wall or ceiling with PVCround block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.

25

-

-

... More
od210958/2019_2020 : Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and commissioning of Surface Panel type LED Round /Square Fittings18-30Watts(Dimension:300mmX40mm) not less than 2500lm lumen and giving connection with 3 core round flex wire .etc .complete.

34

-

-

... More
od210960/2019_2020 : Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and commissioning of Surface Panel type IP65 LED Round /Square Fittings 18-30Watts(Dimension:280mmX52mm) not less than 2500lm lumen and giving connection with 3 core round flex wire .etc .complete.<br>

30

-

-

... More
od141075/2019_2020 : Supply, conveyance, installation, testing and commissioning of pre-wired light fittings made of .5mm thick CRCA sheet accessories and commissioning of Surface Panel type LED Round /Square Fittings12Watts and giving connection with 3 core round flex wire .etc .complete.

18

-

-

... More
od210969/2019_2020 : Supply conveyance, installation, testing and commissioning of pre-wired Sensor type LED the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required<br>1200 mm 1X20W of pre-wired Sensor type LED Lamp with box type fixture<br>

11

-

-

... More
od31752/2020_2021 : Supply, conveyance, installation, testing and commissioning of Recess mounted high efficient LED spotlight,2W, 114 lumens luminaire lumen output, 33 mm cutout dia and 12 mm deapth. Housing made up aluminium and white powder matt coated finish, 60 degree Lens optics for sharp cone without glare Color Temperature-2700K, IP20, Powerfactor>0.9, Surge protection -2KV, 380V AC ,make Wipro ,crompton,or Equivalent and giving connection with 3 core round flex wire .etc .complete. <br>

10

-

-

... More
od31753/2020_2021 : Supply, conveyance, installation, testing and commissioning of Recessmounted full panel LED luminaire with rhombus design on diffuser White powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED Make:Nichia/Cree/Osram/etc, Colour temperature-5600-5900k IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50DegC, Driver Efficiency>90%, THD<15%, Powerfactor>0.9, Surge protection in CM-2KV, ModelMultistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and Safety extra low voltage safe level<60V DC as per IEC Standard.2ft x 2ft, Wattage ≤ 31-40W recess mounted similar to make Wipro,crompton,jaguar,Philips,etc. with luminaire lumen ≥ 3000lm and system efficacy>90lm/W.and including charges for cutting holes & frame for Gypsum/POP ceiling and.giving connection with 3 core round flex wire etc complete. Model Crompton Vectot VI -LCTLRF6-36-CDL or equivalent<br>

6

-

-

... More
od31830/2020_2021 : Supplying and clamping the 20 mm dia sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required.<br>

15

-

-

... More
LED BULB &,LED BULK HEAD

-

-

-

... More
od78036/2019_2020 : Supply,providing,testing and commissioning of 3 to 6 W PWD Approved make LED Bulb

5

-

-

... More
od78057/2019_2020 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb

5

-

-

... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.

10

-

-

... More
od127989/2019_2020 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W LED to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface asrequired

10

-

-

... More
FIXING OF CEILING/EXHAUST/WALL FAN

-

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

125

-

-

... More
od138605/2019_2020 : Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.<br>

125

-

-

... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.

105

-

-

... More
od133246/2019_2020 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame<br>

24

-

-

... More
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

24

-

-

... More
od78103/2019_2020 : Supply, conveyance, installation, testing and commissioning 450 mm (18 inch)wall mounting fan of the following sizes using mounting brackets supplied along with the fan and giving connection with existing wire .Features, Powder Coated Guard with Aluminum Die Casting Blade,Three speeds control mounted within easy reach of hand,vertical adjustment from 22° to 45°,230VAC,50C/S,60/80W Power Consumption,1400/1440 Speed (RPM) , No of speed 3, No of blades 3, Air Delivery 100(M3/min)( Should be make Orient/Havels/Almonard)

10

-

-

... More
SUB MAIN WIRING

-

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

200

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

250

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

200

-

-

... More
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire

100

-

-

... More
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm

100

-

-

... More
1.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm

100

-

-

... More
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

250

-

-

... More
1.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm

100

-

-

... More
1.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm

100

-

-

... More
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

100

-

-

... More
1.17.18 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 2.5 sq. mm

50

-

-

... More
1.17.24 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm

100

-

-

... More
1.17.27 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 4 sq. mm

50

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

750

-

-

... More
1.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm

50

-

-

... More
1.17.5 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm

50

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

300

-

-

... More
1.17.13 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm

50

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

200

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

300

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
MODULAR BOX/SHEET/SWITCH/SOCKETS AND ACCESSORIES

-

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

130

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

35

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

130

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

35

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

5

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

30

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

35

-

-

... More
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

5

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

5

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

50

-

-

... More
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )

13

-

-

... More
90.10.3.32 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )

13

-

-

... More
90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )

13

-

-

... More
SP DB

-

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

7

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

53

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

7

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

7

-

-

... More
od140808/2019_2020 : Supply, conveyance installation testing and commissioning of Timer switches fitting complete with all accessories and giving connection as required,3 module DIN Daily type .<br>TECHNICAL DATA -3P Module 24 hour program ,programmable every 15min .,backup of 100 hrs ., current capacity 16A,with 1 changeover (1 CO) <br>

1

-

-

... More
3P DB

-

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

10

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

162

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

10

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

10

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

18

-

-

... More
VDB

-

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

4

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA 4 Pole

5

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

36

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

12

-

-

... More
MV CABLE LAYING

-

-

-

... More
90.12.5.4 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

110

-

-

... More
90.12.5.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

110

-

-

... More
90.12.5.31 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

30

-

-

... More
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

30

-

-

... More
90.12.6.4 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

72

-

-

... More
90.12.6.42 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

75

-

-

... More
90.12.6.30 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

50

-

-

... More
90.12.6.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

20

-

-

... More
90.12.6.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

10

-

-

... More
90.12.7.4 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

218

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

220

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

250

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

60

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

5

-

-

... More
90.12.5.43 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

100

-

-

... More
90.12.6.43 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

30

-

-

... More
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

50

-

-

... More
90.12.5.33 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

30

-

-

... More
90.12.6.33 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.

15

-

-

... More
90.12.7.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

10

-

-

... More
PROTECTIVE PIPE TO CABLES

-

-

-

... More
90.12.12.5 : Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation

30

-

-

... More
90.12.12.8 : Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation

30

-

-

... More
90.12.12.11 : Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation

30

-

-

... More
END TERMINATION OF CABLES

-

-

-

... More
9.1.3 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)

14

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

16

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

12

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

20

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

6

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
CABLE -BARE EARTHING

-

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

500

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

500

-

-

... More
EARTH CLAMPS

-

-

-

... More
od78046/2019_2020 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip 25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip(2012 kPWD approved rate)

54

-

-

... More
EARTH SOCKETS

-

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

30

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

25

-

-

... More
CABLE TRAY

-

-

-

... More
4.1.4 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.1.1 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.1.2 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.1.3 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.1.5 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness

5

-

-

... More
4.1.6 : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

30

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

60

-

-

... More
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).

60

-

-

... More
PLATE EARTHING

-

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

10

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

100

-

-

... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

5

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

10

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
6.4 : Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

18

-

-

... More
6.3 : Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.

1

-

-

... More
6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For horizontal run)

200

-

-

... More
6.9 : Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For horizontal run)

400

-

-

... More
6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightningconductor complete as required.(For vertical run)

250

-

-

... More
6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

2

-

-

... More
6.15 : Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

10

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

10

-

-

... More
GENERAL SINGES

-

-

-

... More
od78050/2019_2020 : Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height

500

-

-

... More
od78066/2019_2020 : Providing and fixing signage, made of casted acrylic (4mm thick) of approved type and colour, duly Laser cut with text and pictograms(3m, LG) PVC Vinyl reverse pasting/double side tape method, electro cut. All fixing arrangements in minor fasteners, stainless steel screws, with cut etc. Or by hanging using SS chain as per design at the required locations as directed by the Engineers in charge. Rate Is inclusive of all materials, labour charges, scaffoldings etc complete (Approved rate of Government medical college Ernakulam Consultancy work )

1.5

-

-

... More
ELECTRICAL INSPECTORATE APPROVAL

-

-

-

... More
od31739/2020_2021 : Preparation of 3 set of Electric schematic drawing as per Electrical Inspectorate & KSEB rules and get Approval from Electrical Inspectorate concerned , one set of Approved schematic shall be laminated with good quality laminated paper and the same shall be fixed as directed by Engineer in charge <br>(Rate for each set ) Except statutory fee at Electrical inspectorate

5

-

-

... More
od31740/2020_2021 : Provision for statutory fee (like Schematic approval fee, Testing of TriVector meter /CT/Multi Function meter etc as required ) at Kerala State Electricity Licensing Board -Amount will be reimbursed after submitting original document/receipt

1

-

-

... More
MV PANELING

-

-

-

... More
od211713/2019_2020 : supply and installation of mechanical interlock kit for contactor MCX 22 to 23 fitted in the panel board necessary bolts and nuts giving all interconnections etc complete.<br>

6

-

-

... More
od212986/2019_2020 : supply and installation of 4 pole power contactors range of 63 A MCX 12 fitted in the panel board necessary bolts and nuts giving all interconnections etc complete.<br>

10

-

-

... More
od212987/2019_2020 : supply and installation of 4 pole power contactors range of 100 A MCX 22 fitted in the panel board necessary bolts and nuts giving all interconnections etc complete.

2

-

-

... More
od212988/2019_2020 : S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the 200 A, AC 23 A, TPN SDF for DIN fuse ratings:

3

-

-

... More
od212989/2019_2020 : S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the 63 A, AC 23 A, TPN SDF for DIN fuse ratings:<br>

5

-

-

... More
od35754/2020_2021 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.<br>16 Amp-100 Amp, 30 KA 4 Pole

11

-

-

... More
2.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA

2

-

-

... More
90.14.11.5 : MCCB Accessories

1

-

-

... More
90.14.11.3 : MCCB Accessories

1

-

-

... More
90.14.11.13 : MCCB Accessories

13

-

-

... More
90.14.11.15 : MCCB Accessories

2

-

-

... More
90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.

40

-

-

... More
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

9

-

-

... More
90.14.3.3 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board

10

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

10

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

5500

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

1600

-

-

... More
od139952/2019_2020 : LED indicators for all voltage ranges Red,Yellow,Blue Colour<br>

12

-

-

... More
od163884/2019_2020 : Supplying and fixing 100/5 V A, 5 VA, accuracy class 1 , Tape wound Metering CT complete with connections, testing and commissioning etc. as required

16

-

-

... More
od163885/2019_2020 : Supplying and fixing 3 Phase, 4 wire, direct reading, 240 V, 50-100 A , electronic type energy meter ? accuracy class 1 complete with connections, testing and commissioning etc. as required

5

-

-

... More
od163887/2019_2020 : Supplying and fixing Multi function meter to read:V, A, F , 3 phase accuracy class 0.5 complete with connections, testing and commissioning etc. as required

3

-

-

... More
od163899/2019_2020 : Supplying and fixing 3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter ? accuracy class 1 complete with connections, testing and commissioning etc. as required

1

-

-

... More
od163888/2019_2020 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.<br>

500

-

-

... More
od78081/2019_2020 : Fabrication, supply, conveyance and installation of angle iron frame work for wall mounting panel board using suitable size angle iron cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel using required bolt and nuts, fixing the whole to the wall, making good the damages etc. as required.(2012kpwd approved rate)

160

-

-

... More
ELECTRICAL SAFETY EQUIPMENT

-

-

-

... More
od78054/2019_2020 : Supply. Conveyance, installation of Standard First Aid Kit - Minimum quantities may be considered as a general guidance leaflet on first aid.

2

-

-

... More
od78071/2019_2020 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

4

-

-

... More
od78078/2019_2020 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.(2012 kpwd Approved Rate)

3

-

-

... More
od78080/2019_2020 : Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.(2012 kpwd Approved rate)

6

-

-

... More
od78086/2019_2020 : Enameled Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.(2012 kpwd approved rate)

4

-

-

... More
od78088/2019_2020 : Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.( 2012 KPWD Approved rate ) unit rate meter square

10

-

-

... More
TELEPHONE

-

-

-

... More
90.6.9.2 : Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit

149

-

-

... More
90.6.9.4 : Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit

25

-

-

... More
od217200/2019_2020 : Supply and fixing 10 pair PVC Krone box (IP54) with connections and branching points for telecommunication cables

1

-

-

... More
OUT DOOR LIGHTING SYSTEM

-

-

-

... More
od140118/2019_2020 : Supply, conveyance installation testing and commissioning of pre-wired 30W LEDStreet light fitting complete with all accessories and lamps,GI pipe etc and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.,30W LED street light fittings.<br>

3

-

-

... More
FIXTURE NUMBERING

-

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

400

-

-

... More
CAPACITORS

-

-

-

... More
90.14.24.68 : Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.

1

-

-

... More
ACP

-

-

-

... More
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

50

-

-

... More
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall withAluminium Composite Panel Cladding, with open grooves for linear as well ascurvilinear portions of the building , for all heights and all levels etc. including:a) Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to makeit watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium compositepanel cladding in pan shape in metalic colour of approved shades made out of4mm thick aluminium composite panel material consisting of 3mm thick FR grademineral core sandwiched between two Alumini um sheets (each0.5mm thick). Thealuminium composite panel cladding sheet shall be coil coated, with Kynar500based PVDF / Lumiflon based fluoropolymer resin coating of approved colourand shade on face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backerrods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanisedwith serrations and serrated washers to arrest the wind load movement, fasteners,SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators toprevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost ofall mock ups at site, cost of all samples of the individual components for testing inan approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wallwith aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevantaluminium item.s The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face ofthe curtain wall with Aluminum Composite Panel Cladding (including width ofgroove) shall be measured in sqm. up to two decimal places.

10

-

-

... More
Conference Hall

-

-

-

... More
od31713/2020_2021 : supply ,installation testing and commissioning 2TR Inverter type air conditioner of 5 star with suitablestablizer for reputed company make and necessary stand to the out door unit with all copper pipes of Standard length (up to 3 meter) in the convenient position.The air conditioner should be of stand make like voltas, blue star ,hitachi & sharp<br>

2

-

-

... More
od31748/2020_2021 : "supply of Wireless microphone including one cordless mic and one collar mic the should be of standard make like ahuja or equivalent make

1

-

-

... More
od31749/2020_2021 : "supply of Goose neck microphone the should be of standard make like ahuja or equivalent make

1

-

-

... More
od31755/2020_2021 : Supply and drawing the 2 core 1.00 sq. mm. of multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible speaker cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>

150

-

-

... More
od31750/2020_2021 : Supply and fixing 160 watts ,5mic & 2aux input Amplifier with Built in Digital Player (mp3 player with USB ,SD& MMC Card reder and Remort Control,Shoud be of stand make like AHUJA or equilent<br>

1

-

-

... More
od31751/2020_2021 : Supplay and fixing 2way 6''/30Wats ceiling speaker with net guard fitted on celing etc complet ,Shoud be of stand make like AHUJA or equilent<br>

4

-

-

... More
diesel generator

-

-

-

... More
od250253/2019_2020 : Supply, installation, testing and commissioning of 125 KVA AMF silent DG set with CPCB II approved acoustic enclosure and anti vibration pads as per CPCB norms comprising of Cummins Make –Model No C125D5P or suitable equivalent model radiator cooled diesel engine developing 125/100 BHP at 1500 RPM or suitable nearest BHP/RPM complete with standard accessories coupled to stamford /KEL / equivalent alternator rated at 125 KVA at 415 volts, mounted on channel iron base frame complete with fuel tank of 8 hour running or 290 Lr / suitable nearest capacity, standard manual / electronic control panel and 1 no 12 volt battery with lead wire terminals anti vibration mounting pads etc as per electrical inspectorate approval. Including loading and unloading charges and all duties and taxes and including cost for extending exhaust pipe up to the roof top of DG set building by using B class GI/MS pipe of suitable size formation of foundation and installation. Including providing emergency push button. etc complete.<br>Technical Data Latest Technology and unmatched Performance, Environment Friendly Power, Lowest operating cost& comprehensive warranty, single source power assurance,<br>Engine -Technical Data Generator Set Specification Model C125D5P Duty Prime Prime Power Rating kVA / kWe 125 No. of Phases 3 Phase 1 Phase Output Voltage (V) 415 V 230 V Power Factor 0.8 (lagging) 0.8 (lagging) Current (3 phase/ 1 phase) (A) 70 217 Frequency (Hz) and RPM 50 Hz, 1500 RPM Engine Specification Make Cummins Model 6BTAA5.9-G13 MoEF Certified Power (hp) 84 Required Power for Rated kVA (hp) 66 Cooling Liquid Cooled (EG Complete 50:50) Aspiration -Turbocharged, Charge Air Cooled No. of cylinders 4 Bore (mm) x Stroke (mm) 95 x 115 Compression ratio 19:1 Displacement (litre) 3.3 Fuel High Speed Diesel Fuel consumption @75% load with radiator and fan* (litre/hr) 9.6 110.15 Fuel consumption @100% load with radiator and fan* (litre/hr) 12.44 13.28 Performance class of generator set ISO 8528-5 G2 Starting system 12 V DC Electrical Lube oil specification CI4+ 15W40 Lube oil sump capacity, High-Low level (litre) 7 - 5.5 Total lubrication system capacity (litre) 7.9 Lube oil consumption @ full load** (litre/hr) 0.01 Total coolant capacity (litre) 13 Exhaust pipe size (inch) 3 Total wet weight (Engine +Radiator) (kg) 375 Length x Width x Height (Engine) (mm) 1066 x 725 x 1033 Mean piston speed (m/s) 5.75 Combustion air intake @100% load (±5%) (cfm) 160 Exhaust Temperature (°C) 490 <br> Alternator Specification - Make Alternator frame Enclosure Voltage regulation (Max.) Class of Insulation Winding Pitch Stator Winding Rotor Waveform distortion/ Total Harmonic Distortion Maximum Unbalanced Load across phases# Telephonic Harmonic factor Stamford (CGT) UCI224D UCI224G IP23 ±1% H Class 2/3 Double layer lap Dynamically Balanced No load < 1.5 %, Non distorting balanced linear load < 5 % less than or equal to 25% < 2%including cost of construction of plinth with RCC, truss roof sheet & installation of exhaust piping complete with thermal insulation with mineral wool and AI cladding MS pipe of suitable dia,heavy duty bend,flexible connector and supports 200mm etc complete

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.