Kerala State Housing Board Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Construction Of Govt. Employees Flats Mchs Stage Ii, Kozhikode Internal Electrification Work Including 25kva Dg Set
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KSHB_469421_1Bid Award Id
ViewTender No
KSHB/RE/KKD/05/2021-2022Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block
including connection etc as required.
255
-
-
... More
od198453/2021_2022 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.<br>Group A
66
-
-
... More
LIGHTS
-
-
-
... More
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
150
-
-
... More
od198452/2021_2022 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W LED to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface asrequired
6
-
-
... More
od198454/2021_2022 : SITC of standard make 20 to 25 W LED out door Gate Light IP 66 Protection
2
-
-
... More
od198455/2021_2022 : Supply and fixing Sintex box 200x150mm for gate light &street light
10
-
-
... More
od198456/2021_2022 : Supply and providing the following types and power rated LED Down Light round/squre typelamps in the existing fittings as required 15 to 18 w LED Down Light
2
-
-
... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
63
-
-
... More
od198458/2021_2022 : Supply and providing the following types and power rated lamps in the existing Angle holder/fittings as required 8W LED BULB
69
-
-
... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
5
-
-
... More
90.3.18.2 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
5
-
-
... More
CEILING FAN, EXHAUST FAN &amp; CALL BELL
-
-
-
... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
63
-
-
... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
63
-
-
... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
63
-
-
... More
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
39
-
-
... More
od198457/2021_2022 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.305 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C
39
-
-
... More
90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
12
-
-
... More
PVC CONDUITS
-
-
-
... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1000
-
-
... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
250
-
-
... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
25
-
-
... More
DB AND ACCESSORIES
-
-
-
... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
13
-
-
... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
130
-
-
... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
1
-
-
... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
14
-
-
... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
14
-
-
... More
CIRCUIT MAINS
-
-
-
... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1200
-
-
... More
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
200
-
-
... More
1.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
50
-
-
... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
250
-
-
... More
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
101
-
-
... More
6A AND 16A SOCKETS &amp; SWITCHES
-
-
-
... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
66
-
-
... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
72
-
-
... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
66
-
-
... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
72
-
-
... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
12
-
-
... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
54
-
-
... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
84
-
-
... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
3
-
-
... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
12
-
-
... More
FIRE EXTINGUISHER
-
-
-
... More
od198449/2021_2022 : Supply and installing Fire extinguisher-ABC 4.5 to 5 kg capacity, made out of 1.5 mm thicknes mild steel of IS:513 grade with chemical test certificate , brass forged valve presure guage with manufacture test certificate, ISI marked mono aluminium phosphate 90% powder with certificate, Epoxy powder coated with shade 538 of is:5 with aluminum syphon holder and aluminum shyphon pipe, ISI marked hose with 12.5 mm I.D operating temperature 20 to 55 degree centigrade certification of nitrogen gas grade1 quality with purity of 99.997% ,fire rating 2a 21Bof IS 15683:2006 ISI Marked -make: Warrior or the standard make
3
-
-
... More
od198451/2021_2022 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.(2012 kpwd approved rate)
3
-
-
... More
EARTHING
-
-
-
... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
... More
5.5 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
1
-
-
... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
10
-
-
... More
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
... More
5.13 : Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
25
-
-
... More
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
30
-
-
... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
20
-
-
... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
80
-
-
... More
5.12 : Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
40
-
-
... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
28
-
-
... More
WATER PUMP
-
-
-
... More
od198448/2021_2022 : Supply and installation of Standard /reputed company make 3 HP open well submersible pump set in to the water sump ,including DOL starter and connected accessories for functioning the pump . hanging the motor inside the sump by using materials and giving existing delivery pipe lines connections works up to existing delivery line, fixing control panel board, giving all electrical and plumbing connections, testing, commissioning, etc complete. Including hire charges for tools and plants required for the works.
1
-
-
... More
od198450/2021_2022 : Suction & delivery fittings such as foot valve, delivery side NRV, 2no wheel valve and and giving connection
1
-
-
... More
CABLING
-
-
-
... More
90.12.1.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 35 sq mm
20
-
-
... More
90.12.5.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm
30
-
-
... More
90.12.5.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
10
-
-
... More
90.12.6.13 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 6 sq mm
25
-
-
... More
90.12.6.28 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm
15
-
-
... More
90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
230
-
-
... More
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
30
-
-
... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
100
-
-
... More
90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
30
-
-
... More
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm
232
-
-
... More
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
6
-
-
... More
90.12.24.7 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm
32
-
-
... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
12
-
-
... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
12
-
-
... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
2
-
-
... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
8
-
-
... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
58
-
-
... More
25kVA DG
-
-
-
... More
od198462/2021_2022 : SuSupply, installation, testing and commissioning of 20KW/25 KVA, Three phase Diesel Generating Setwith CPCBII approved acoustic enclosure comprising of: “Cummins” Model X2.7T-G1, Radiator CooledDiesel engine 1500 RPM, complete with standard accessories. Coupled to “Stamford” Alternator rated at20KW/25 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Fuel Tank,. AMFControl System complete with standard accessories coupled to stamford /KEL / equivalent alternatorrated at 40KW/50 KVA at 415 volts, mounted on channel iron base frame complete with fuel tank of 8hour<br>running or 85 Lr / suitable nearest capacity, standard manual / electronic control panel and 1 no12 volt battery with lead wire terminals anti vibration mounting pads etc as per electrical inspectorateapproval. Including loading and unloading charges and all duties and taxes and including cost forextending exhaust pipe up to the roof top of DG set building by using B class GI pipe of suitable sizeformation of foundation and installation. Including providing emergency push button. etc complete. withthe following specification<br>Technical Data<br>Generator set specification-Model C25D5P C30D5PDuty Prime Prime<br>Power Rating kVA / kWe 25/20 30/24-No. of Phases 3 Phase 3 Phase<br>OutputVoltage (V) 415 415-Power Factor 0.8 (lagging) 0.8 (lagging)<br>Current (3 phase/ 1 phase) (A) 35 42-Frequency (Hz) and RPM 50 Hz, 1500 RPM 50 Hz, 1500 RPM<br>Engine Specification-MakeCummins® Cummins®-Model X2.7TA-G1 X2.7TAA-G2-MoEF Certified Power (bhp) 32 38.5-RequiredPower for Rated kVA (bhp) 31.6 38.1-Cooling Liquid Cooled (EG Compleat 50:50) Liquid Cooled (EGCompleat 50:50)-Aspiration Turbocharged Turbocharged, Charge Air Cooled-No. of cylinders 3, In-line 3,In-line-Bore (mm) x Stroke (mm) 95 x 127 95 x 127-Compression ratio 18.3:1 18.3:1-Displacement (litre)2.7 2.7<br>Fuel High Speed Diesel High Speed Diesel-Fuel consumption @75% load with radiator andfan* (litre/hr) 4.6 5.61-Fuel consumption @100% load with radiator and fan* (litre/hr) 6.27 7.45-Performance class of generator set ISO 8528-5 G2 ISO 8528-5 G2-Starting system 12 V DC Electrical 12V DC Electrical-Lube oil specification CH4 15W40 CH4 15W40-Lube oil sump capacity, High-Low level(litre) 7.3-3.2 7.3-3.2-Total lubrication system capacity (litre) 8 8-Total coolant capacity (litre) 11 11-Exhaust pipe size (inch) 2.5 2.5-Total wet weight (Engine+Radiator) (kg) 322 322-Length x Width xHeight (Engine) (mm) 701 x 600 x 889 701 x 600 x 889<br>Mean piston speed (m/s) 6.35 6.35-Combustion air intake @100% load (±5%) (cfm) 67 70-Exhaust Temperature (°C) 463 487-AlternatorSpecification<br>Make Stamford (CGT) Stamford (CGT)-Alternator frame S0L2M1S0L2P1<br>Enclosure IP23 IP23-Voltage regulation (Max.) ±1% ±1%-Class of Insulation H Class HClass-Winding Pitch 2/3 2/3-Stator Winding Double layer lap Double layer lap-Rotor DynamicallyBalanced Dynamically Balanced-Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Nondistorting<br>balanced linear load < 5 %-No load < 1.5 %, Non distorting-balanced linear load < 5 %-Maximum Unbalanced Load across phases# less than or equal to 25% less than or equal to 25%-Telephonic Harmonic factor < 2% < 2%<br>
1
-
-
... More
METERING PANEL 1 & 2
-
-
-
... More
od234785/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, bus bar chambers with copper bus , hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi function meter suitable CTs, danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc. The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase of size 25X6, Insulated neutral copper bus of size 25 x 3. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.INCOMER 100AMP, 30kA 4P MCCB -1 NO ,OUT GOINGS 63 AMP 16 KA 4P SFU -6 NOS, 6 NO.S OF ACCL , Panel Shall be Electrically Interlocked If necessary, Spare compartment shall be with sealing provision. The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as per Electrical Inspectorate, KSEB, CPRI & other relevant codes and standards.
2
-
-
... More
MSB
-
-
-
... More
od235109/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, bus bar chambers with copper bus , hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi function meter suitable CTs, danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc. The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase of size 25X6, Insulated neutral copper bus of size 25 x 3. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.INCOMER 200AMP, 36kA 4P MCCB -1 NO ,OUT GOINGS 160 AMP 36 KA 4P SFU -3 NOS, Panel Shall be Electrically Interlocked If necessary, Spare compartment shall be with sealing provision. The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as per Electrical Inspectorate, KSEB, CPRI & other relevant codes and standards.
1
-
-
... More
UTILITY PANEL
-
-
-
... More
od235112/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, bus bar chambers with copper bus , hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi function meter suitable CTs, danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc. The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase of size 25X6, Insulated neutral copper bus of size 25 x 3. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.INCOMER 125A MOTORIZED CHANGE OVER -1 NO ,OUT GOINGS 40A DP MCB - 4 NO.S, Panel Shall be Electrically Interlocked If necessary, Spare compartment shall be with sealing provision. The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as per Electrical Inspectorate, KSEB, CPRI & other relevant codes and standards.
1
-
-
... More
GDB PANEL
-
-
-
... More
od235111/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, bus bar chambers with copper bus , hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi function meter suitable CTs, danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc. The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase of size 25X6, Insulated neutral copper bus of size 25 x 3. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.INCOMER 100AMP, TPN ISOLATOR -1 NO ,OUT GOINGS 63 AMP TPN ISOLATOR -2 NOS, 6A DP MCB - 13 NO.S, Panel Shall be Electrically Interlocked If necessary, Spare compartment shall be with sealing provision. The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as per Electrical Inspectorate, KSEB, CPRI & other relevant codes and standards.
1
-
-
Evaluation Notes How It Works ?
Potential Partner