Kerala State Housing Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 3,100Tender Fee
Refer Documents
Summary
Kshb Thu Re Tender Construction Of Building Under Aswas
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KSHB_688017_1Tender No
2023_RE_KSHB-THU_03(Ele)_2(a)Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
25
-
-
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
122
-
-
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
53
-
-
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
92
-
-
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block
including connection etc as required.
189
-
-
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required. (For light plugs to be used in non residential
buildings).
158
-
-
SUB MAIN WIRING
-
-
-
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
750
-
-
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
-
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
100
-
-
1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
100
-
-
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1000
-
-
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
300
-
-
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
300
-
-
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
90
-
-
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
100
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
600
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
300
-
-
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
200
-
-
TV, TELEPHONE, NET WORK
-
-
-
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
300
-
-
od69944/2023_2024 : Supply and laying 20 pair armoured telephone cable 0.75m below ground level including excavation of soil: ordinary soil
50
-
-
od69946/2023_2024 : Supply and fixing 20 pair PVC Krone box (IP54) with connections and branching points for telecommunication cables
3
-
-
FIXING LED TUBE ,SURFACE PANEL,BULB,BULK HEAD
-
-
-
od69942/2023_2024 : Supply, conveyance, installation, testing and commissioning of Slim panel Surface mounted 300x300 mm down lighter with all accessories, housing made up of die cast aluminium for better heat management. Hight Transmittivity Diffuser for better light output and uniform light distribution without glare. Driver and accessories are pre wired for easy installation and long service. CRI>70, Color temperature>6000K, IP20, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection 2KV, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Square Slim surface mounted, Wattage ≤ 24W, similar to Wipro ,crompton,or Equivalent with luminaire lumen ≥ 2000 lm and giving connection with 3 core round flex wire .etc .complete.<br>
10
-
-
od69945/2023_2024 : Supply, conveyance, installation, testing and commissioning of LED Bulkhead fitting with all accessories, aluminium diecast housing with powder caoted wire guard. CRI>70, LED Make: Nichia/Cree/Osram/ Lumiled, LED Efficacy>120lm/W, color temperature-5700K, IP65 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering > 720lm, similar to WIPRO ,CROMPTON,JAQUAR OR Equivalent
10
-
-
od69950/2023_2024 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br>
92
-
-
od69951/2023_2024 : Supply conveyance, installation, testing and commissioning the light fittings of following types made with White powder coated/pre coated finish, CRCA channel for single for 1200 mm 18W/20W LED tube having IP20 , 6500K, 20W LED T8 - 2000 lumens, Aluminum housing with PC diffuser, THD<20%, Surge - 2kV, CRI-80, 50000 burning hours, single sided connection,. Multistage Isolated Constant Current Operated driver with range 110-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required<br>1200 mm 1X20W Aluminum housing with PC diffuser LED Tube with box type fixture
106
-
-
od69953/2023_2024 : Scrapping painting in the existing Street light pole (5m) 2cote enamel painting & Supply, installation testing and commissioning of pre-wired 35W LED Street light fitting complete with all accessories and lamps ,GI Arm and clamp for fixing Light etc post top including supply of 3C x 1.5 Sq.mm flexible Copper cable for interconnection etc. complete and as required as directed by the EIC. Make Wipro, Crompton, Philps or Equivalent and giving connection with 3 core round flex wire, MCB-6A, Nuteral link,with base plate and accessories including RCC pedestal of suitable size as per drawing of manufacturer for mounting octagonal street light pole including excavation, providing CC Foundation 1:2:4 work, grouting of J hook type bolt (4 Nos.), plastering, coping and finishing the surface, installation of octagonal street light poles on concrete pedestal etc .complete. With luminaries lumen 4200lm and System Efficacy 120lm/W
4
-
-
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
3
-
-
90.15.4.7 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
FIXING CELLING,EXHAUST FAN
-
-
-
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
52
-
-
od69948/2023_2024 : Supply, conveyance, installation, testing and commissioning of the 225mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,225mm metal frame.
52
-
-
od69952/2023_2024 : Supply conveyance installation testing and commissioning of 25 L water storage capacity Geyser with inlet and outlet valve having a natural flow of water and storing hot water at the storage tank with the required capacity
3
-
-
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
53
-
-
SP DB,3P DB&VDB
-
-
-
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
126
-
-
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
18
-
-
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
25
-
-
2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
4
-
-
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
7
-
-
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
7
-
-
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
7
-
-
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
4
-
-
2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2
-
-
MODULAR BOX,PLATE,SWITCH,SOCKETS &ACCESSORIES
-
-
-
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
26
-
-
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
48
-
-
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
40
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
40
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
40
-
-
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
38
-
-
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
76
-
-
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
76
-
-
od69955/2023_2024 : Supplying and fixing following modular key card switch 2 module - credit card size key fob on the existing modular plate & switch box including connections but excluding modular plate etc. as required.<br>16A key card switch 2 module - credit card size key fob
22
-
-
od69956/2023_2024 : Supplying and fixing following modular buzzer on the existing modular plate & switch box including connections but excluding modular plate etc. as required.<br>Buzzer
40
-
-
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )
40
-
-
MV CABLE LAYING
-
-
-
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation
30
-
-
9.1.3 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)
2
-
-
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
14
-
-
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
6
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
300
-
-
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
25
-
-
90.12.2.4 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
10
-
-
90.12.2.42 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
100
-
-
90.12.2.43 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)
50
-
-
90.12.6.4 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
6
-
-
90.12.6.42 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
25
-
-
90.12.6.43 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
20
-
-
PLATE EARTHING
-
-
-
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
10
-
-
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth
electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
50
-
-
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
25
-
-
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
30
-
-
solar on grid
-
-
-
od69941/2023_2024 : Supply, Installation, Testing and commissioning of on grid solar photovoltaic Power Plant , Conforming to MNRE Specification as amended, consisting of Mono/Poly crystalline silicon solar cell, Net metering facility, necessary protections , earthing mounted on Aluminium /GI Structure of suitable strength with following components complete as required.<br>a)Solar photovoltaic module of capacity 330 wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part -2, Solar photovoltaic Module conversion efficiency shall not be less than 16.5%, PV Modules used in solar power plants /systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10 years and 80 % at the end of 25 years.<br>b)Power conditioning unit (PCU) of 350-800 V DC input voltage range and 400 V AC, three phase 4 wire , 50 hz +/- 2.5hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the grid voltage frequency.<br>c)Data monitoring system complete with all accessories.<br>d)Fixing of array junction box & main junction box with IP 65 Protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc as required <br>f) connection and interconnection by supplying & fixing required size XLPE insulated copper conductor 1.1 KV grade armoured power and control cable between solar modules, main power cable to grid supply PCU Unit along with supplying & fixing of necessary channel / conduit lugs and other accessories etc as required .( RATE FOR 1 kWp ) COST/kWp
5
-
-
panel board
-
-
-
od69943/2023_2024 : Fabrication, supply, conveyance, installation testing and commissioning floor Mounting, dust and vermin proof, cubicle type LV panel board comprising of the following Components devices complying to IS 8623. Fabrication of fully partitioned, dust and Vermin proof enclosure for panel assembly using 1.6mm CRCA sheet as per approved Design and requirement 2mm for frame, with front access facility, bus bar chambers with Aluminium bus hinged doors for all switch gear compartments and earthling the Doors using braided copper conductor and providing indication lamps, digital type Multi Function meter suitable CTs danger notice board etc the board should be powder Coating the assembly after subjecting to 7tank process as required. 2 No’s Copper earth Bar of size 25 mm x 3 mm at the rear with 2No. Earth stud Angles/ flats/ slotted angles Etc shall not be used for the fabrication of panel assembly. The panel Board should be Fitted on the base frame for panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint Over a coat of zinc chromate paint bottling the frame to the panel and to the furnished Floor using required bolts and nuts making good the damages colour washing and Including providing and fixing the following switch gears etc as required Panel Incomer EB: 250A 4P 35KA Thermal Magnetic MCCB with ICU=ICU with OC SC Releases, Speeders & RHOM - 1No Meters & Relays (Note: the doors should have facility for sealing by KSEB Incomer - EB)(a) 3 Phase, 4 wire,CT operated , 240 V, 5-10 A ,electronic type energy meter Accuracy class 1 -1Set (b) Digital Multifunction meter with communication port to Display the Voltage Current, Power, Frequency, Power factor with the necessary CT's- 3 No. (c) Low set earth fault protection relay with suitable CT- 3No) 1No Over Voltage Relay & under Voltage Relay - 1No RYB Indication lamp with 2A MCBs-3 set,Outgoing 160A, 4P, 36kA, MCCB with thermal Magnetic release for adjustable OL & SC protection - 1no 100A, 4P, 36kA, MCCB with thermal Magnetic release for adjustable OL & SC protection - 3no 63A 4P, 36kA, MCCB with Thermal magnetic release for adjustable OL & SC protection - 2 NO’S TPN AL bus bars suitably rated for 150A SFU 4 pole isolator
1
-
-
KSEB
-
-
-
od159457/2023_2024 : Provision for a statutory fee (like Schematic approval fee (Preparation of 3 sets of Electric schematic drawings as per Electrical Inspectorate & KSEB rules and get With approval concerned, one set of Approved schematics shall be laminated with good quality laminated paper and the same shall be fixed as directed by Engineer in charge (Rate for each set ) Except for statutory fee at the Electrical inspectorate), (Testing of TriVector meter /CT/Multi-Function meter, etc as required ) at Kerala State Electricity Licensing Board- if needed) and statuary fee at KSEB Limited for effecting Electric connection -Amount will be reimbursed after submitting original document/receipt
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements