Kerala State Housing Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Housing Board - KSHB Tender

Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Apr 2023
Closing Date22 Apr 2023
Tender Amount₹ 52,32,816 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

752

-

-

... More
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.

27

-

-

... More
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture

401

-

-

... More
od270290/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.<br>Group A

40

-

-

... More
1.4 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

6

-

-

... More
90.3.19.4 : 1200 mm 2X20W LED Lamp with box type fixture

66

-

-

... More
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

27

-

-

... More
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.

3

-

-

... More
od269945/2020_2021 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.305 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C

27

-

-

... More
od269949/2020_2021 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.450 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C

3

-

-

... More
od14449/2021_2022 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS, With following specification HEAVY DUTY PEDESTAL AIRCIRCULATOR, Adjustable height, Strong streamlined pedestal for greater stability, Three speed control mounted on the column within easy reach of hand Sweep 450 mm, volts 230v, AC Cycles 50 c/s, Power 100w, Speed 1400 rpm, phase 1, Air Delivery 150 m3/min, No of blades 3, no of speed 3 as per the direction of Engineer in charge <br><br>

13

-

-

... More
od14450/2021_2022 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. With following specification HEAVY DUTY WALL AIRCIRCULATOR, Three speed, verticle Adjustable, Aluminium alloy one piece blade, Double ball-bearing 90. Oscillation, Study close-mesh guard beautiful design, Powerful heavy-duty motor, Sweep 450 mm, volts 230v, AC Cycles 50 c/s, Power 100w, Speed 1400 rpm, phase 1, Air Delivery 150 m3/min, No of blades 3, no of speed 3 as per the direction of Engineer in charge

30

-

-

... More
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.

58

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

66

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

24

-

-

... More
od270103/2020_2021 : Supply and fixing cast aluminium stove enameled bulk head fittings with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9W LED to wall / ceiling including giving connections with required length of 6/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the srface asrequired

5

-

-

... More
od270086/2020_2021 : Supply and providing the following types and power rated lamps in the existing Angle holder/fittings as required 8W LED BULB

32

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

1700

-

-

... More
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

1020

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

175

-

-

... More
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

200

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

450

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

200

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

20

-

-

... More
1.21.4 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm

10

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

58

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

20

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

20

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

40

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

2

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

8

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

400

-

-

... More
od305828/2021_2022 : Supply, Installation, Testing and Commissioning of 1200<br>mm sweep, BEE 5 star rated, ceiling fan with Brush Less<br>Direct Current (BLDC) Motor, class of insulation: B, 3 nos.<br>blades, 30 cm long down rod, 2 nos. canopies, shackle kit,<br>safety rope, copper winding, Power Factor not less than<br>0.9, Service Value (CMM/W) minimum 6.85, Air delivery<br>minimum 215 CMM, 350 RPM (tolerance as per IS : 374-<br>2019), THD less than 10%, remote or electronic regulator<br>unit for speed control and all remaining accessories<br>including safety pin, nut bolts, washers, temperature<br>rise=75 degree C (max.), insulation resistance more than<br>2 mega ohm, suitable for 230 V, 50 Hz, single phase AC<br>Supply, earthing etc. complete as required.<br>

58

-

-

... More
LIGHT FITTINGS

-

-

-

... More
od269487/2020_2021 : Supply, Installation, Testing and Commissioning of LED RGB/RGBW<br>floodlighting luminaire for facade lighting with Die-cast aluminium<br>housing, powder-coated finish, of following wattage. Luminaire<br>shall be capable of producing dynamic color changing light for with<br>16 million colors by DMX/Ethernet based control. The beam angle<br>of the fitting shall be narrow, medium, wide or asymmetric as per<br>the requirement. Luminaire shall be complete with driver and<br>capable of operating at line voltage without any separate power<br>supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture<br>shall be suitable to operate at an ambient temperature range of -<br>10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at<br>least L70:50000 burning hours at 50°C. Luminaire shall be<br>conforming to BIS (IS 10322) and shall be complete with all<br>necessary accessories required for proper working of fixture<br>including weather proof connection cables, water proof connectors<br>etc. as required. 45 W/40 W floodlighting RGB/RGBW luminaire i/c all accessories, fittings, supports etc.

5

-

-

... More
od34081/2021_2022 : Supply, Installation, Testing and commissioning of Approved Make and Model Auditorium Function LED Light Surface/Recess mount with the following specification Luminous flux (Luminaire): 2937 lm Luminous flux (Lamps): 2968 lm Luminaire Wattage: 18 W Luminaire with more than 100 lm/w with THD less than 10%, PF more than 0.9 with Aluminium body with powder coated classification according to CIE: 99 CIE flux code: 47 78 95 99 99 Fitting, Correction Factor 1.000) LPD 12.9 W/M2, cri 80-85 as per the Direction of Engineer in Charge

75

-

-

... More
od34082/2021_2022 : Supply, Installation, Testing and commissioning of Approved Make and Model Auditorium Function LED Light Surface/Recess mount with the following specification Luminous flux (Luminaire): 2937 lm Luminous flux (Lamps): 2968 lm Luminaire Wattage: 30 W Luminaire with more than 100 lm/w with THD less than 10%, PF more than 0.9 with Aluminium body with powder coated classification according to CIE: 99 CIE flux code: 47 78 95 99 99 Fitting, Correction Factor 1.000) LPD 12.9 W/M2, cri 80-85 as per the Direction of Engineer in Charge

97

-

-

... More
od269488/2020_2021 : Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear WallWasher luminaire for Facade lighting with aluminium extruded housing, of<br>following wattage. Luminaire shall be capable of producing dynamic color<br>changing light with 16 million colors by DMX/Ethernet based control. The beam<br>angle of the fitting shall be narrow, medium, wide or asymmetric as per the<br>requirement. Luminaire shall be complete with driver and capable of operating<br>at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz,<br>power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature<br>range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at<br>least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and<br>shall be complete with all necessary accessories required for proper working of<br>fixture including weather proof connection cables, water proof connectors etc.<br>as required. 40 W floodlighting RGB/RGBW luminaire i/c all accessories, fittings, supports etc.

5

-

-

... More
od270221/2020_2021 : SITC of standard make 20 to 25 W LED out door Gate Light IP 66 Protection

2

-

-

... More
od270222/2020_2021 : Supply and fixing Sintex box 200x150mm for gate light &street light

18

-

-

... More
90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

1

-

-

... More
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

10

-

-

... More
90.3.18.2 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps

10

-

-

... More
LED DOWN LIGHT

-

-

-

... More
od267881/2020_2021 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and LED lamps directly on Recess and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 18 to 20 w Square / Round LED Down Light including control drive KSHB/ PWD Approved make and model.

12

-

-

... More
LED ARCHITECTURE LIGHT FITTINGS ONLY

-

-

-

... More
od267866/2020_2021 : <br>Supply conveyance, installation, testing and commissioning the following types of ceiling mounting Architectural Hanging fittings including provision for giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required & LED Bulb/HUE Bulb Fitting holder Approved Make and Model as directed by Engineer in charge

4

-

-

... More
od267883/2020_2021 : Supply conveyance, installation, testing and commissioning the following types of ceiling mounting Architectural Hanging fittings including provision for giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required & LED Bulb/HUE Bulb Fitting holder Standard make and model

2

-

-

... More
od267899/2020_2021 : Supply conveyance, installation, testing and commissioning the following types of ceiling mounting Architectural Hanging fittings including provision for giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required & LED Bulb/HUE Bulb Fitting holder Standard Make and Model

2

-

-

... More
STRIP LIGHTING

-

-

-

... More
od267867/2020_2021 : Supply and installation of flexible ordinary(White) 20 w led strip uses high brightness smd led as the light source for indoor application only. it is highly suitable for cove-lighting, decorative lighting etc maximum 5 meter set (Including control drive) KSHB/PWD Approved standard make

10

-

-

... More
od267884/2020_2021 : Supply and installation of flexible ordinary 20 w led PHILIPHS or equivalent RGB strip uses high brightness smd led as the light source for indoor application only. it is highly suitable for cove-lighting, decorative lighting etc maximum 5 meter (including control drive) 1 set RGB Strip = 5 meter

5

-

-

... More
SPOT LIGHTING

-

-

-

... More
od267885/2020_2021 : Supply conveyance, installation, testing and commissioning the SPOT light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on Ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required -LED Spot Light Approved Make and Model 50 Watts (KSHB/PWD Approved make and model( LED COB Down Lighter)

6

-

-

... More
MIRROR LIGHTING

-

-

-

... More
od267868/2020_2021 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required -Linear & compact 9 w mirror light with decorative grey end ca, poly carbonate body IP 65 protection and ribbled opal diffuser Approved make and model

7

-

-

... More
WALL MOUNTING LIGHT

-

-

-

... More
od267869/2020_2021 : Supply conveyance, installation, testing and commissioning the following types of WALL mounting 10 W Architectural TWO WAY UP AND DOWN LIGHT fittings including provision for giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required & LED Bulb/HUE Bulb Fitting holder (Approved Make and Model )

6

-

-

... More
EARTH CLAMPS

-

-

-

... More
od267871/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip 25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip(2012 kPWD approved rate)

20

-

-

... More
od267887/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip(2012 kpwd approved rate)

38

-

-

... More
CABLE TRAY

-

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
PIPE/PLATE EARTHING

-

-

-

... More
od267872/2020_2021 : Supply and providing ISI pipe earthing as per IS 3043 with 3.5 m long 40 mm dia B class GI pipe providing GI Funnel with weld mesh fixing GI strip of size 50x6 mm with minimum length of 20 cm clamped with 50 mmx6 mm GI Flat using 12x10 mm GI bolt and nut at top of the GI Pipe at a radius of 15cm with a homogeneus mixture of charcoal common salt and river sand up to of 2.5 mtrs from the bottom filling the rest of portion with excavated soil including watering and hammering providing brick work 20cm masonry at the top in 1:6 cement mortar plastering the inside and top of the man hole with 12 mm thick 1:6 cement mortar and providing gully trap with CI covering at top etc complete

1

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

5

-

-

... More
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip

5

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

100

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

20

-

-

... More
GENERAL SINGES

-

-

-

... More
od267874/2020_2021 : Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height

150

-

-

... More
od267889/2020_2021 : Providing and fixing signage, made of casted acrylic (4mm thick) of approved type and colour, duly Laser cut with text and pictograms(3m, LG) PVC Vinyl reverse pasting/double side tape method, electro cut. All fixing arrangements in minor fasteners, stainless steel screws, with cut etc. Or by hanging using SS chain as per design at the required locations as directed by the Engineers in charge. Rate Is inclusive of all materials, labour charges, scaffoldings etc complete (Approved rate of Government medical college Ernakulam Consultancy work )

1.5

-

-

... More
ELECTRICAL SAFETY EQUIPMENT

-

-

-

... More
od267877/2020_2021 : Supply. Conveyance, installation of Standard First Aid Kit - Minimum quantities may be considered as a general guidance leaflet on first aid.

2

-

-

... More
od267894/2020_2021 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

4

-

-

... More
od267903/2020_2021 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.(2012 kpwd Approved Rate)

6

-

-

... More
od267905/2020_2021 : Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.(2012 kpwd Approved rate)

6

-

-

... More
od267910/2020_2021 : Enameled Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.(2012 kpwd approved rate)

4

-

-

... More
od267913/2020_2021 : Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.( 2012 KPWD Approved rate ) unit rate meter square

10

-

-

... More
CABLE

-

-

-

... More
90.12.5.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 6 sq mm

64

-

-

... More
90.12.6.3 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm

7

-

-

... More
90.12.6.13 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 6 sq mm

8

-

-

... More
90.12.6.40 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm

6

-

-

... More
90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm

30

-

-

... More
90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp

61

-

-

... More
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

8

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

54

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

264

-

-

... More
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm

10

-

-

... More
90.12.6.29 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm

5

-

-

... More
90.12.7.18 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 50 sq mm with factory made clamp

5

-

-

... More
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm

16

-

-

... More
90.12.24.4 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm

14

-

-

... More
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm

48

-

-

... More
90.12.24.8 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.50 sq mm

12

-

-

... More
90.12.2.28 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 35 sq mm

70

-

-

... More
90.12.6.28 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm

10

-

-

... More
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

20

-

-

... More
90.12.24.7 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm

12

-

-

... More
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

400

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

120

-

-

... More
90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)

40

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

26

-

-

... More
90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)

60

-

-

... More
90.16.5.6 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)

20

-

-

... More
90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size

30

-

-

... More
90.12.9.3 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size

35

-

-

... More
90.6.6.4 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm

60

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

8

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

6

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

12

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

12

-

-

... More
DB AND ACCESSORIES

-

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

6

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

2

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

3

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

2

-

-

... More
2.9.6 : Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator). (Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)6 way Double door

1

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

2

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

5

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

3

-

-

... More
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

5

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

88

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

2

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

15

-

-

... More
WATER PUMP

-

-

-

... More
od270808/2020_2021 : Supply, erection, testing and commissioning of 2 HP or nearest suitable size 3 Ph 440V, 50Hz mono block pump set 440V, 50Hz with formation of foundation, GM/Brass NRV, wheel vale, foot valve all are ISI, suction line,

2

-

-

... More
LIGHTENING ARRESTER

-

-

-

... More
6.2 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

4

-

-

... More
6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

120

-

-

... More
6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

30

-

-

... More
6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

25

-

-

... More
KSEB METER BOARD

-

-

-

... More
od270282/2020_2021 : Fabrication, supply &amp; installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB TOD meter, 3 nos fuse units, Neutral Link CT etc, ELR with CBCT up to 200 amp hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.& Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. including control wiring. Including supply and fixing 1no 200 AMP MCCB 35/36 ka, 3no cut outs, neutral link , lead wire, viewing glass etc are in a chamber and providing provision for fixing 1 no 3 phase TOD energy meter with including Cost of 3no CT in separate chamber, ELR with CBCT etc as per KSEB &amp; inspectorate rule.(Including supply and fixing indication RYB lamp as per standard but Excluding TOD Meter)

1

-

-

... More
CABLE MANAGEMENT SYSTEM

-

-

-

... More
90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid

150

-

-

... More
90.9.2.2 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider

50

-

-

... More
90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree

30

-

-

... More
90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap

30

-

-

... More
90.9.2.10 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover

30

-

-

... More
FIRE EXTINGUISHER

-

-

-

... More
od270801/2020_2021 : Supply and installing Fire extinguisher-ABC 4.5 to 5 kg capacity, made out of 1.5 mm thicknes mild steel of IS:513 grade with chemical test certificate , brass forged valve presure guage with manufacture test certificate, ISI marked mono aluminium phosphate 90% powder with certificate, Epoxy powder coated with shade 538 of is:5 with aluminum syphon holder and aluminum shyphon pipe, ISI marked hose with 12.5 mm I.D operating temperature 20 to 55 degree centigrade certification of nitrogen gas grade1 quality with purity of 99.997% ,fire rating 2a 21Bof IS 15683:2006 ISI Marked -make: Warrior or the standard make

8

-

-

... More
50kVA GENERATOR

-

-

-

... More
od305860/2021_2022 : Supply, Installation, Conveyance, Testing and commissioning of 1 number 50 KVA DG set with standard control (AMF Operation) CPCBII approved acoustic enclosure comprising of Approved Make and Model, Radiator Cooled Diesel engine 1500 RPM, complete with standard accessories. Coupled to Approved Alternator rated at 50 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Fuel Tank Standard Automatic Control System and Batteries.at site including Exhaust pipe, transportation charges, labour charges etc as required.as per direction from Engineer in charge.

1

-

-

... More
COMMON AMF PANEL

-

-

-

... More
od305938/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with front access facility, bus bar chambers with copper bus , hinged doors for all switch gear compartments and earthing the doors using braided copper conductor and providing indication lamps, digital type Multi function meter suitable CTs, danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc. The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase of size 25X6, Insulated neutral copper bus of size 25 x 3. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.INCOMER 100AMP 4P MCCB TYPE ISOLATOR -2 NO ,OUT GOINGS 50 TO 63 AMP 16 KA 4P MCCB -4 NOS, Panel Shall be Electrically Interlocked If necessary, Spare compartment shall be with sealing provision. The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as per Electrical Inspectorate, KSEB, CPRI & other relevent codes and standards.<br>

1

-

-

... More
HVLS & COOLING TOWER FAN

-

-

-

... More
od305939/2021_2022 : Supply,Conveyance,installation,testing and commisioning of Helicopter type (HVLS) suitable for Auditorium function with the following specification High Quality Aluminium Magnesium alloy tensile blade,Special design and twist of the blade makes maximum cool airmovement, low air cutting noise, noise free high end fan motor,no of blade 5, colourdesign optional, speed 0-50 rpm single phase, wattage 1.3 KW, Controls Variable speed, Coverage 1500m2, weight approximate 109 kg, Mounting height minimum 15ft finished floor to Fan, Motor PMSM, Sound 38db,including fabrication materials and work as per the direction of Engineer in charge <br>

3

-

-

... More
od305940/2021_2022 : Supply,Conveyance,installation,testing and commisioning of Cooler Tower Fan floor mounted reputed make and model with the following specifications ,Storage Capacity 90 liters,Cooling medium -Hybrid Pad,Blower/Fan- Fan,Power Consumption 190 watts, Cater wheels, Approximate 5 nos wheel, Tank fill- Automatic, Termal over load Protection,Cord winter, Manual Control, Approximate weight 16 kg, Water inlet, works on inverter as per the direction of Engineer in charge<br>

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.