Kerala State Housing Board Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala State Housing Board - KSHB Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 May 2023
Closing Date5 Jun 2023
Tender Amount₹ 3,31,14,790 
Notes
Download

Costs

Summary

Electrification Works For The Parasparyam House Scheme Neelambari At Ambalanagar Thiruvananthapuram

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

500

-

-

... More
od6025/2023_2024 : Wiring for twin control light point / fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthling the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

630

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

440

-

-

... More
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.

705

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

1646

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1027

-

-

... More
SUB MAIN WIRING

-

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

4800

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

2500

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2000

-

-

... More
1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

800

-

-

... More
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

500

-

-

... More
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire

800

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

1000

-

-

... More
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm

800

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

1000

-

-

... More
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm

500

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

800

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

5500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1800

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

800

-

-

... More
90.1.1.1 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm

3000

-

-

... More
90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm

1200

-

-

... More
90.1.1.3 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement, tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm

800

-

-

... More
TV, TELEPHONE, NET WORK

-

-

-

... More
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair

1000

-

-

... More
od6006/2023_2024 : Supply and laying 20 pair armoured telephone cable 0.75m below ground level including excavation of soil: ordinary soil

150

-

-

... More
od6009/2023_2024 : Supply and fixing 20 pair PVC Krone box (IP54) with connections and branching points for telecommunication cables

10

-

-

... More
1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

4800

-

-

... More
FIXING LED TUBE ,SURFACE PANELLED BULB ,LED BULK HEAD, LED POST TOP LAMP, LED BOLAD,LED STREET LIGHT,

-

-

-

... More
od5995/2023_2024 : Supply, conveyance, installation, testing and commissioning of Slim panel Surface mounted down lighter with all accessories, housing made up of die cast aluminium for better heat management. Hight Transmittivity Diffuser for better light output and uniform light distribution without glare. Driver and accessories are pre wired for easy installation and long service. CRI>70, Color temperature>6000K, IP20, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection 2KV, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Square Slim surface mounted, Wattage 15-18W, similar to Wipro ,crompton,or Equivalent with luminaire lumen ≥ 2000 lm and giving connection with 3 core round flex wire .etc .complete.<br>

214

-

-

... More
od5999/2023_2024 : Supply, conveyance, installation, testing and commissioning of LED Bulkhead fitting with all accessories, aluminium diecast housing with powder caoted wire guard. CRI>70, LED Make: Nichia/Cree/Osram/ Lumiled, LED Efficacy>120lm/W, color temperature-5700K, IP65 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<20%, Powerfactor>0.95, Surge protection in CM-2KV, Multistage Isolated Constant Current-Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering > 720lm, similar to WIPRO ,CROMPTON,JAQUAR OR Equivalent

55

-

-

... More
od6012/2023_2024 : "Supply, conveyance, installation, testing and commissioning of High efficient LED Post Top luminaire with Aluminium housing in pure polyster UV resistant powder coated black finish housing , Top maintainable product with top opening die cast cover, Acylic clear glass reflector, IP65 protection, Suitable for pole dia. Up to 50 mm.Luminaire lumen>1900 lm, System Efficacy>95 lm/W, LED With 50000 burning hours as per L70 Criteria, Colour Temperature- 5700K, CRI >70, In-built electronic driver duly wired up to terminal block. Temperature range- 0 to 45 DegC, Driver efficiency>85%, Power factor>0.95, THD<10%, Surge protection in CM-4 KV, Multistage Isolated Constant Current- Operated driver with range150-300 V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.LED post top luminaire, 20 W With 3 mtr Round GI Pu coated pole with outer dia 50mm suitable to mount 20W post top with base plate and accessories including RCC pedestal of suitable size as per drawing of manufacturer for mounting<br>octagonal street light pole including excavation, providing form work, grouting of 'J' hook type bolt (4 Nos.), plastering, coping and finishing the surface, installation of octagonal street light poles on concrete pedestal including supply of 3C x 1.5 Sq.mm flexible<br>Copper cable for interconnection etc. complete and as required asdirected by the EIC. make Wipro ,crompton,or Equivalent and giving connection with 3 core round flex wire .etc .complete.<br>"<br>

7

-

-

... More
od6019/2023_2024 : Supply, conveyance, installation, testing and commissioning of 35W High efficient LED Streetlight Suitable for external pole dia. Up to 45 mm, with Aluminium pressure Die cast housing parts for long life, Pure polyester powder coated Dark Gray housing, High purity PMMA lenses for superior performance, Toughened glass with silicon gaskets for IP66 protection,LED with 50000 burning hours as per L70 Criteria,LED Make-Nichia/Cree/Osram, CRI >70,Colour Temperature- 5700K, in-built Isolated Constant Current Operated Electronic Potted driver pre- wired up to terminal block,Input Voltage Range 110V-320V, Surge protection 4KV ,Internal Low Voltage and High Voltage Cut off With Auto re-start facility, 440V operation for 8 hours Temperature range- 0 to 45DegC, Driver efficiency>85%, THD <=10% ; PF >=0.9, =and Safety Extra Low Voltage Safe level<60V DC as per IEC standard 5 Mtr Octagonal GI Pole suitable with base plate, .5 Mtr Arm and all accessories required, 35W post top with base plate and accessories including RCC pedestal of suitable size as per drawing of manufacturer for mounting<br>octagonal street light pole including excavation, providing form work, grouting of 'J' hook type bolt (4 Nos.), plastering, coping and finishing the surface, installation of octagonal street light poles on concrete pedestal including supply of 3C x 1.5 Sq.mm flexible<br>Copper cable for interconnection etc. complete and as required as directed by the EIC. make Wipro ,crompton,or Equivalent and giving connection with 3 core round flex wire .etc .complete. with luminaire lumen ≥ 4200lm and System Efficacy ≥ 120lm/W With <br>

14

-

-

... More
od6022/2023_2024 : Supply, conveyance, installation, testing and commissioning of LED Bollard ,Dark grey, pure polyester powder coated aluminum extruded housing , seamless, asymmetric PC diffuser for better Light Transmission, Product is designed for IP 65 protection, Luminaire lumen>555 lm, System Efficacy>50 lm/W, Temperature range- 0 to 50DegC, LED With 50000 burning hours as per L70 Criteria,CRI >80,Colour Temperature- 5700K, IP 65 potted driver and accessories pre-wired up to terminal block. Driver efficiency>80 %, Power factor>0.95, THD<25%, Surge protection 2KV, , Multistage Isolated Constant Current Operated driver with range 180-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.LED bollard, 8W -10W similar to Wipro ,crompton,or Equivalent and giving connection with 3 core round flex wire, including RCC pedestal of suitable size as per drawing of manufacturer for mounting<br>octagonal street light pole including excavation, providing form work, grouting of 'J' hook type bolt (4 Nos.), plastering, coping and finishing the surface, installation of octagonal street light poles on concrete pedestal including supply of 3C x 1.5 Sq.mm flexible<br>Copper cable for interconnection etc. complete and as required as directed by the EIC..etc .complete.<br><br>

15

-

-

... More
od6023/2023_2024 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br>

20

-

-

... More
od6024/2023_2024 : Supply conveyance, installation, testing and commissioning the light fittings of following types made with White powder coated/pre coated finish, CRCA channel for single for 1200 mm 18W/20W LED tube having IP20 , 6500K, 20W LED T8 - 2000 lumens, Aluminum housing with PC diffuser, THD<20%, Surge - 2kV, CRI-80, 50000 burning hours, single sided connection,. Multistage Isolated Constant Current Operated driver with range 110-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required<br>1200 mm 1X20W Aluminum housing with PC diffuser LED Tube with box type fixture

106

-

-

... More
od11949/2023_2024 : Supply, conveyance, installation, testing and commissioning of LED Recessed foot lamp ( step lamp) with all accessories fitting with aluminium diecast housing with powder caoted wire guard. CRI>70, Lumiled,color temperature-3000K, IP66 rated, 50000 burning hours as per L70 Criteria, Ambient temp-0 to 45DegC, Driver efficiency>75%, THD<15%, Powerfactor>0.95, Surge protection in CM-4 KV, Constant Voltage Operated driver with range 110-320V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. 3 W LED Step light luminaire delivering > 60lm, similar to WIPRO ,CROMPTON,JAQUAR OR Equivalent

270

-

-

... More
FIXING CELLING,EXHAUST FAN

-

-

-

... More
od5989/2023_2024 : Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE -5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 no’s .blades, 30 cm long down rod, 2 no’s Canopies, shackle kit, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 9.17, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,(Working in remote or electronic regulator), unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthling etc. complete as required

30

-

-

... More
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.

285

-

-

... More
od6007/2023_2024 : Supply, conveyance, installation, testing and commissioning of the 225mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,225mm metal frame.

5

-

-

... More
od6015/2023_2024 : Supply, conveyance, installation, testing and commissioning of the 305 mm exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS,305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame<br>

10

-

-

... More
SP DB,3P DB & VDB

-

-

-

... More
2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required100 Amp, 30 KA 4 Pole

8

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

15

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1240

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

18

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

100

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

15

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

95

-

-

... More
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

95

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

15

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

5

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

90

-

-

... More
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.21 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

5

-

-

... More
MODULAR BOX,PLATE,SWITCH,SOCKETS & ACCESSORIES

-

-

-

... More
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

90

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

400

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

375

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

454

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

454

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

454

-

-

... More
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

90

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

200

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

85

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

570

-

-

... More
90.10.3.17 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket

655

-

-

... More
90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell

10

-

-

... More
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator

195

-

-

... More
90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket

195

-

-

... More
PLATE EARTHING

-

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
od6001/2023_2024 : Supply and providing earthing with CI earth plate 1200mm x 1200mm x 12.6mm thick electrode including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke as required conforming to relevant IS and Electrical Inspectorate standards etc including excavation and refilling<br>

10

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

60

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

200

-

-

... More
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

500

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

500

-

-

... More
90.16.1.10 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)

1000

-

-

... More
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip

300

-

-

... More
SOLAR ON GRID

-

-

-

... More
od5997/2023_2024 : Supply, Installation, Testing and commissioning of on grid solar photovoltaic Power Plant , Conforming to MNRE Specification as amended, consisting of Mono/Poly crystalline silicon solar cell, Net metering facility, necessary protections , earthing mounted on Aluminium /GI Structure of suitable strength with following components complete as required.<br>a)Solar photovoltaic module of capacity 330 wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part -2, Solar photovoltaic Module conversion efficiency shall not be less than 16.5%, PV Modules used in solar power plants /systems must be warranted for their out put peak watt capacity, which should not be less than 90% at the end of 10 years and 80 % at the end of 25 years.<br>b)Power conditioning unit (PCU) of 350-800 V DC input voltage range and 400 V AC, three phase 4 wire , 50 hz +/- 2.5hz, out put voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the grid voltage frequency.<br>c)Data monitoring system complete with all accessories.<br>d)Fixing of array junction box & main junction box with IP 65 Protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc as required <br>f) connection and interconnection by supplying & fixing required size XLPE insulated copper conductor 1.1 KV grade armoured power and control cable between solar modules, main power cable to grid supply PCU Unit along with supplying & fixing of necessary channel / conduit lugs and other accessories etc as required .( RATE FOR 1 kWp ) COST/kWp

10

-

-

... More
MV CABLES & ACCESSORIES

-

-

-

... More
90.12.5.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm

100

-

-

... More
90.12.39.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 4 sq mm

150

-

-

... More
90.12.40.1 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 4 sq mm

30

-

-

... More
90.12.5.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm

60

-

-

... More
90.12.6.2 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 6 sq mm

40

-

-

... More
90.12.6.3 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm

25

-

-

... More
90.12.6.4 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 16 sq mm

40

-

-

... More
90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm

480

-

-

... More
90.12.6.43 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 35 sq mm

140

-

-

... More
90.12.7.4 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 16 sq mm with factory made clamp

420

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

3000

-

-

... More
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp

780

-

-

... More
9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

55

-

-

... More
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)

10

-

-

... More
9.1.3 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 16 sq. mm (22mm)

20

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

180

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

20

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

24

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

8

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

4

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

6

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

10

-

-

... More
90.12.5.37 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 400 sq mm

90

-

-

... More
90.12.6.30 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 70 sq mm

150

-

-

... More
90.12.6.32 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm

50

-

-

... More
90.12.6.34 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 185 sq mm

80

-

-

... More
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm

120

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

50

-

-

... More
90.12.6.35 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm

40

-

-

... More
90.12.6.37 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm

200

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

50

-

-

... More
90.12.7.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm

60

-

-

... More
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm

60

-

-

... More
90.12.7.37 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm

200

-

-

... More
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size

200

-

-

... More
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size

520

-

-

... More
90.12.12.13 : Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size

100

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

6600

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

250

-

-

... More
90.16.2.2 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)

30

-

-

... More
90.16.2.4 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)

25

-

-

... More
90.16.2.5 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)

30

-

-

... More
90.12.41.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

630

-

-

... More
od16358/2023_2024 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. 4 core 4 sq mm

84

-

-

... More
od16406/2023_2024 : Supplying and making end termination with brass compression gland and aluminium lugs for <br>following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV <br>grade as required.<br>4 X 4sq. mm

42

-

-

... More
od29034/2023_2024 : Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.<br>6core 2.5 sq mm

100

-

-

... More
HT CABLE

-

-

-

... More
od5993/2023_2024 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 11 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.<br>3 core 300 sq mm

25

-

-

... More
od6013/2023_2024 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required.<br>3 core 300 sq mm

35

-

-

... More
od6017/2023_2024 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.<br>3 core 300 sq mm

100

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

2

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

2

-

-

... More
PANEL BOARD

-

-

-

... More
od5996/2023_2024 :Supply, Installation, Testing & Commissioning of MSB -A, cubicle type panel board, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free-standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with a neoprene / PU gasket, etc. The panel shall include the supply & installation of the following switchgear, metering instruments, and accessories as required. The LT panel shall be with validated design and fully comply with the requirements of Type Tested Assemblies (TTA) Switchboards shall be certified by 3rd party Certification body as per IEC 61439-1 & 2. The switchboard shall be tested for Internal Arc as per IEC 61641. The test should be performed for the Arc starting place - at the Horizontal busbar, Vertical busbar, and in outgoing cable compartments. Test reports without a certificate shall not be considered admissible proof of compliance. The Certifying Authority shall be qualified under ISO/IEC 17065 as per IEC 61439-1. The type-tested designs of the switchboards shall be proven designed by the switchgear manufacturer (OEM) Switchboards shall have a short circuit level of a minimum of 50 KA and withstand for 0.3secs. Switchboards shall have a Rated Impulse withstand voltage of 12kv All covers and doors provided shall offer adequate safety to operating persons and provide ingress protection of IP 42 unless otherwise stated. Switchboards shall be validated design for Seismic withstand as per standard IEC60068. Switchboards must have mechanical impact IK10 tested Switchboard’s construction shall employ the principle of compartmentalized and metallic segregation for each circuit Switchboard panels and cubicles shall be fabricated with CRCA Sheet Steel of thickness, same as that of tested assembly per IEC61439-1 & 2 Doors with transparent safety glass with aesthetic appeal to avoid all risk of injury. Switchboards and non-forced air-ventilated switchboards shall be enabled with a Din rail wireless sensor capable of monitoring the system and generating 3 levels of alerts on overheating wire connections or cables. Each column of the electrical switchboard shall include one wireless sensor at the top, to help the user to prevent electrical switchboards from being damaged, by analyzing gas and particles in the air and sending alerts before any smoke or insulator browning occurs. (Note: All the doors should have a facility for sealing by KSEB) Incomer- EB ACB 1000A FP 50KA EDO TYPE MP BASED 3O/C + 1E/F release - 1 nos Instruments *6A, C curve SP MCB - 1 set *RYB indication lamp, LED type - 1 set *On, Off, Trip indication lamp, LED type - 1 set *1000/5A 15VA class 1 resin cast CT - 1 set Digital Multi-function meter with RS485 communication port PM2230 Outgoing.630A, , TPN, 36kA, MCCB with double break type and microprocessor release 2 no's *250A, , TPN, 36kA, MCCB with double break type and microprocessor release - 1 no with 3phase LT TOD energy meter 4nos cast resin CT of 250/5A, 0.5S Class, 10VA. All the outgoing MCCBs with Spreader and ROH BUSBAR: the suitable rating of Aluminium bus bar as per type test

1

-

-

... More
od6004/2023_2024 : Supply, Installation, Testing & Commissioning of SSB, cubicle type panel board, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free-standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC the system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with a neoprene / PU gasket, etc. The panel shall include the supply & installation of the following switchgear, metering instruments, and accessories as required. The LT panel shall be with validated design and fully comply with Type Tested Assemblies (TTA) requirements as per IEC 61439-1&2. All MCCB shall confirm to Ics=100% Icu. The enclosure, busbar, busbar supports, etc shall take care of normal stress as well as abnormal electro-mechanical stress due to short circuit conditions. The type-tested certificates complying with IEC 61439 shall be submitted. Incomer *630A, FP, 36kA, MCCB with double break type & thermal magnetic release for adjustable OL & SC protection - 1 no. Instruments*2A, C curve SP MCB - 1 set *RYB indication lamp, LED type - 1 set On, Off, Trip indication lamp, 1 set *1 set 3 phase Digital Multi-function meter with RS485 communication port PM2230. *600/5A 15VA class 1 resin cast CT - 1 set Outgoing. *200A, TP, 36kA, MCCB with with thermal magnetic release for adjustable OL & SC protection - 5 nos

2

-

-

... More
od6010/2023_2024 : Supply, Installation, Testing & Commissioning of cubicle type panel board, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free-standing, floor mounting, dust, and vermin proof, powder-coated, indoor, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC the system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with a neoprene / PU gasket, etc. The panel shall include the supply & installation of the following switchgear, metering instruments, and accessories as required. The LT panel shall be with validated design and fully comply with Type Tested Assemblies (TTA) requirements as per IEC 61439-1&2. All MCCB shall confirm to Ics=100% Icu & double break type. The enclosure, busbar, busbar supports, etc shall take care of normal stress as well as abnormal electro-mechanical stress due to short circuit conditions. The type-tested certificates complying with IEC 61439 shall be submitted. Incomer*400A 4P, WATSN ATS with Micro controlled (ATS should be solenoid drive, integrated controller type, three-position, and specific transfer switching equipment. The two sources can be isolated in the off position with a padlock. The utilization category must meet AC-33B without the current duration. Rated short-time withstand current, which must be provided along with a third-party test report, shall be specified in the tender documents and be in accordance with the value specified in 8.2.5.1 in IEC 60947-6-1(Standard for ATS), ensure on load transfer between two low voltage power supply; Three operating modes: self-return, on return and manual return, should be field adjustable. parameters such as over/under voltage, and transfer/retransfer delays shall be field adjustable ), but one device can be provided for in-depth settings and other on-site operation, maintenance, and commission) - 1 nos. with battery charger – 1 set, Instruments*2A, C curve SP MCB - 1 set*RYB indication lamp, LED type - 2 set On, Off, Trip indication lamp, LED type - 1 set *1 set 3 phase Digital Multifunction meter with .*250/5A 15VA class 1 resin cast CT - 1 set Outgoing.*125A, TP+NL 36kA, MCCB with the thermal magnetic release for adjustable OL & SC protection - 2 no. *100A, TP+NL, 36kA, MCCB, double break type with the thermal magnetic release for adjustable OL & SC protection - 2nos. *63A, TP+NL, 36kA, MCCB, with the thermal magnetic release for adjustable OL & SC protection - 6nos

1

-

-

... More
od6020/2023_2024 : Fabrication, supply, conveyance, installation testing, and commissioning floor mounting Metering panel, dust and vermin proof, cubicle type LV panel board comprising of the following components/ devices &amp; complying with IS 8623.&lt;br&gt; Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminium bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor The board should be powder coating the assembly after subjecting to 7 tank process as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The cubical panel board shall have compartments, Suitable for fixing ACCL, KSEB METER&4 Pole MCB of size not less than 300 mm x 600 mm and viewing glass for all outgoing compartment doors of a suitable size but not less than 100 mm x 100 mm 3 mm including providing interconnection between all the switch gears with 6 Sq mm PVC insulated copper conductor cable. The panel Board should be fitted on the base frame for the panel board using channels of class designation 75 including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel, and to the furnished floor using required bolts and nuts making good the damages colour washing and fixing the following switch gears, etc as required. (Note: All the doors should have a facility for sealing by KSEB). Incomers. 160.A 4 pole, MCCB KSEB complete with handle assembly,4 poles 63A MCB for DG incomer with double pole-10 A-8nos for ACCL supply incomer. Outgoing. SITC of 3 phase 4 wire direct reading 240V,10-60Aelectronic type energy meters with LCD display accuracy class 1 (KSEB tested)- 8 Nos. 63 A Bakelite type Cut-out fuse with a suitable rating of HRC. -24 Nos, 32 A NL-8Nos .63A 4P MCB -8Nos, three-phase ACCL 40/32 A having site programmable DG overload current right from 1A to maximum rating of the device. ACCL should have password protection. ACCL should have metering of both EB and DG also ACCL should provide protection from Over Current, Under voltage, Phase loss, and Voltage error. -8Nos, "C" curve, miniature circuit breaker etc.

10

-

-

... More
DIESEL GENERATOR & DG sub panel

-

-

-

... More
od14838/2023_2024 : EXHAUST PIPES - Supplying and fixing exhaust gas piping of suitable dia, welded black M.S class 'B' pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports, and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool / Rockwool, 50 mm thick wire mesh & aluminium cladding, etc. after applying one coat HR paint as per manufacturer recommendation, as required as per specifications. suitable rain cap for the top to avoid rainwater entry. The distance between the exhaust pipe at the top and the rain cap should be higher than the diameter of the pipe. The horizontal run of exhaust piping should slope downwards away from the engine to the condensate trap. Silencer should be installed with a drain plug at the bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer, and the rate inclusive of all minor civil works required, bolts, clamps, etc as required for istallation. Support to exhaust piping should be done in such a manner that a load of exhaust piping is not exerted on the turbo charger and the vertical run of the pipes shall be provided with the indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust for 250 kVA DG Set

35

-

-

... More
od14840/2023_2024 : Supply, installation, testing, and commissioning of 3phase, 415 V, 0.8 PF 50 Hz radiator cooled DG set of the rating 250 kVA Prime Duty Diesel Generator Set comprising of diesel engine alternator, fuel tank, starting system, battery, battery charger, electronic governor, etc with all accessories required for synchronizing the DG with another DG's. The battery charger of the auxiliary DC power supply unit, with dry batteries with connecting leads and terminals with stationary type, high discharge performance, Valve Regulated Lead Acid (VRLA) sealed maintenance free, battery charger including all other accessories like interconnecting cables etc as required for complete installation. The Generator set shall have an integral type acoustic enclosure as per the latest CPCB norms. The diesel engine shall be suitable for the continuous operation of the generator set and satisfies EURO-II specifications. with standard control panel

1

-

-

... More
od27960/2023_2024 : Fabrication, supply, conveyance, installation testing, and commissioning floor mounting Dg panel sub panel, dust, and vermin proof, cubicle type LV panel board comprising of the following components/ devices &amp; complying with IS 8623. Fabrication of fully partitioned, dust and vermin-proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement 2mm for the frame, with front access facility, bus bar chambers with aluminum bus, hinged doors for all switch gear compartments and earthing the doors using braided copper conductor the board should be powder coating the assembly after subjecting to 7 tank processes as required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear with 2 No. earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The cubical panel board shall have compartments. Incomer*400A, TP+NL, isolator - 1nos.*, Instruments*2A, C curve SP MCB - 1 set*RYB indication lamp, LED type - 1 set On, Off, Trip indication lamp, LED type - 1 set *1 set 3 phase Digital Multifunction meter with .*400/5A 15VA class 1 resin cast CT - 1 set Outgoing.*250A, TP+NL 36kA, MCCB with the thermal magnetic release for adjustable OL & SC protection - 1 no. 250A, TP+NL, isolator - 1nos *100A, TP+NL, 36kA, MCCB, with the thermal magnetic release for adjustable OL & SC protection - 4nos

1

-

-

... More
TRANSFORMER

-

-

-

... More
od14798/2023_2024 : UNITIZED SUBSTATION - Supply, installation, testing & commissioning of 630 kVA 11kV/433V indoor cast resin Dry-type CRGO core Transformer, (Copper Double Wound) with OFF load tap changer, 630A, load break Switch having a continuous rating for 11kV / 433V 3 phase 50 Hz. Vector group Dyn 11 with tapping +5% to -5% in steps of 2.5 % by tap links include separate winding temperature indicator for each phase and core in the Transformer. The transformer should have a cable end box on the HV side suitable for 3CX300 sq. mm XLPE Cable and an LV side suitable for 4X400 A2XFY Cable, with all accessories, complete as required as per State electricity board, ECBC, and IE rules specifications. The LT side of the transformer shall accommodate the LT TOD meter facility with 4nos of 1000/5A, CL 0.5S, 10VA CT (the cost for the LT TOD meter and CTs shall be included). The transformer shall confirm to IS 2067/77, 11171/1985 with the latest amendment. Foundation for TXR shall be done by other agencies

1

-

-

... More
od16423/2023_2024 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.

3

-

-

... More
od16445/2023_2024 : Preparation of all drawings submitting and getting approval from the Electrical Inspectorate, submitting of Completion certificates and arranging an inspection, getting sanctions and energization certificates, and test reports. Preparation of shop drawings for execution at the site and getting the approved by the engineer in charge/consultant before execution at the site, preparation of As-built drawings of installation upon completion. Obtaining manuals, technical details, and as-built/GA drawings of all types of equipment from the concerned and also obtaining all necessary sanctions from relevant regulatory boards, submitting of test certificates of all types of equipment obtaining power allocation & power connection, etc. for the commissioning of the whole installation in the premises. All statutory payments will be reimbursed on the production of the original receipts. And also preparing MEP coordination drawings for the site ( Electrical ELV ,fire , HVAC )

1

-

-

... More
RMU & 2-POLE

-

-

-

... More
od5998/2023_2024 : Supply and assist in erection, testing and commissioning of dust and vermin proof,floor mounted,free standing cubicle type,communicable type 11KV Metal Enclosed Outdoor Extensible at one end ,Compact Ring Main Unit {RMU}made out of welded pressure tank of IP66 class of protection fully compartmentalized complete with hinged and earthed front doors interlocked with the earth switch.The switch gear should have the minimum degree of protection (in accordance with IEC 60529)<br>- IP 66 for the tank with high voltage components<br>- IP 54 for the front covers of the mechanism<br>- IP 54 for the cable connection covers <br>Supply and installation of the unit costing of 11KV, 630A, 20KVA,Motor operated,Compact,Outdoor,with O/C &EF self powered relays extensible at one end ,non drawout type,CCV +(2nos.Load Break Switch(OD)incomer and 1 no. fixed motor operated Vacuum Circuit Breaker(VL) outgoing or GCB(SF6)compact gas insulated Ring Main Unit,All live parts enclosed (SF6)IN a robotically welded pressure steel tank of IP 67 class of prote

1

-

-

... More
od6002/2023_2024 : Supply and erection of Double pole structure using 10.5mtr 200 x 100mm RS joist with required quantity of 100 x 50mm MS channel for mounting AB switch, DO fuses, Lightning arrestors,etc with Ms flats clamps,base plate, bolts nuts etc., including cutting, welding, aluminium painting all as per standard requirements of Electrical inspectorate, complete including supply and installation of following overhead line accessories as required.<br>11KV pin insulators.<br>11KV Disc insulators.<br>11KV, 400A, 3 phase gang operated , vertical single make/break type off load Air breake switches complete with all hardwares like insulators, fixing channels, operating rods, handle locking arrangements, bolts nuts and complete.<br>9kv, 5kA lighting arrestor <br>11kV, 400A dropout fuse sets, complete with all hard ware like supporting insulators , fuse rods, bolts and nuts complete.<br>4Nos.Pipe earth electrode for the DP structure & LA Earthing , 6 SWG Copper for Lightning arrestor earthing including all round fencing to a height of 1.8 meter with allround clearance of 1.25 meter and filling of 40mm granite gelly in the yard.

1

-

-

... More
MS chequered plate & Elastomeric fire retardent insulating mat

-

-

-

... More
od5990/2023_2024 : Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength. <br>

60

-

-

... More
od6005/2023_2024 : Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength. <br>

100

-

-

... More
od6008/2023_2024 : Supply and providing MS chequered plate of suitable thickness including cutting, welding, painting etc. as required for the cable trench covering.<br>

2500

-

-

... More
od6014/2023_2024 : Fabrication, supply, conveyance and installation of angle iron framework, using suitable size angle iron cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel using required bolt and nuts, fixing the whole to the wall, making good the damages etc. as required.<br>450 mm width X50 mm depth X 2.0 mm thickness

300

-

-

... More
od6018/2023_2024 : Supply and fabrication conveyance and installation of C –CHANEL for Fixing panel board using suitable size,cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer etc complete. using 75 mm X 40 mm X 6 mm channel iron (ISMC)

36

-

-

... More
od6021/2023_2024 : Supply and fabrication conveyance and installation of C –CHANEL for Fixing panel board using suitable size,cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer etc complete. using 100 mm X 50 mm X 6 mm channel iron (ISMC)

60

-

-

... More
OPEN TRENCH

-

-

-

... More
od5991/2023_2024 : Construction of RCC electrical trench size 60cmX100cm with iron tray. Including necessary earth work excavtion, Laying position cement concrete :1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate40 normal size ) 10cm thick, Laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work of base and wall 10cm thick, using cement content as per approved design mix, including pumping of concrete tooted of laying and the cost of entering, shuttering, finishing and steel reinforcement 10mm dia bar used for main bar 20cm c/c and8mm dia bar used for distributer 25cm c/cR.C.C work including straightening, cutting , bending, placing inposition and binding all complete thermo - mechanically Treated bars of grade Fe-500D or more, including admixtures in recommended proportions, 12mm cement plaster of mix:1:4 ( 1 cement : 4 coarsesand ), steel work in built up section used for iron tray (25x25x3mm angle iron for main longitudinal section in each side ,10mm square rod for longitudinal intermediate section in 20cm c/c and 25x3mm flatfor cross section 30cm c/c) thickness , and including cost of cable tray- installing 50 mm width X 30 mmdepth X 1.6 mm size of perforated pre-painted M.S. cable trays with <br>perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.<br>Construction of RCC electrical cabletrench size 60cmX100cm with iron tray &50 mm width X 30 mm depth X 1.6 mm cable tray, size cost ofOne meter ,etc complete

10

-

-

... More
WATER PUMPS

-

-

-

... More
od5992/2023_2024 : Supplying, installation, testing, and commissioning of electrically driven submersible pump set consisting of the following, complete in all respects, as required: Submersible pump set shall be suitable for Vertical / Horizontal installation, 150 mm dia multistage, cast iron body with stainless steel impeller and shaft, water filled and water lubricating type Submersible pump set shall be of suitable HP and capable for discharge 25000 LPH against 49 Mtrs and operation on 415 volts, 3 phase, 50 Hz, AC supply. Supplying and laying PVC insulated PVC sheathed 6 Sq mm multistage three core copper conductor flat cable for submersible pump set….90 Mtr. ( 2 Runs, each run 45 Mtr)Proffered make:- Kirloskar make model No. 150HHF0805 or similar of CRI/Compton/Tex mo.( Note:- 1) Scope of work includes providing and fixing two runs of 10 mm dia flexible GI steel rope, and the required quantity of SS cast wire rope clips to hang the submersible pump set ) It is suggested order a pump set along with control cable 2 runs to avoid underground joint).

2

-

-

... More
od6003/2023_2024 : Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Panel fabricated out of 14 guage CRCA sheet steel in cubical compartmentallised, wall mounted totally enclosed, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats if required. The general construction shall confirm to IS:8623/93. Cable gland plates shall be provided on top as well as bottom of the panels with minimum 3mm thick plate. Panels shall be treated with all anti-corrosive process before painting as per specification, prepareably epoxy coated painting. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels. IN COMING a ) 32 A FP MCCB Thermal magnetic release,Ics=100% Icu, 10 KA ( DY125U of L&T or Equivalent of approved make) -1 No b) Busbar:100 A 4 stripn Aluminium Busbar of suitable length.The busbar shall be insulated by heat shrinkable sleeves …..1 Setc ) 0 - 500 V volt meter, 0 - 60 A ammeter,CT, sclector swttch ,LED type indication lamp, Taggle switch and HRC backup fuses etc.- 1 set OUT GOING a ) 16 A TP MCB …..3 Nos b ) 32 A SPN MCB…...1 No c) Fully automatic star delta starter open execution type suitable for 7.5 HP submersible pump set including internal wiring /ON/OFF button etc as required…...2 Nos c ) 3 KVAR heavy duty capacitor with MOC3 contactor….1 No<br>

1

-

-

... More
CABLE TRAY

-

-

-

... More
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres

10

-

-

... More
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.6.9 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.375 mm width X 62.5 mm depth X 2.0 mm thickness

5

-

-

... More
4.6.10 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thicknessICDDescriptionUnit

5

-

-

... More
4.6.11 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
4.6.12 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.750 mm width X 62.5 mm depth X 2.0 mm thickness

10

-

-

... More
4.6.13 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.900 mm width X 62.5 mm depth X 2.0 mm thickness

15

-

-

... More
LIGHTENING PROTECTION SYSTEM

-

-

-

... More
od14787/2023_2024 : Providing maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length, having a diameter of 14.2 mm with a copper coating thickness of 250 microns with fault current withstand capability of 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp (14 25 RTC) made of SS 304 for clamping. The earth-enhancing compound is used form improving soil conductivity. The material shall be mineral inert to the subsoil and shall not pollute the environment and non-corrosive<br>to earth rod. The material should have a resistivity of less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have 25 kg/pit of the total composite. Polypropylene & Polyethylene (UFE)Earth electrode inspection chamber<br>with a heavy-duty cover should be used to cover the Earth Rod. The dimension shall be 250mmx 250mmx 250mm with a weight-bearing capacity of 50KN.<br>

7

-

-

... More
od14788/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius was tested. Conductor holder @ 1-meter distance, including all accessories as required for complete installation as instructed by the engineer in charge. Horizontal run - Parapet application

180

-

-

... More
od14789/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For concrete building Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius was tested. Conductor holder @ 1-meter distance, including all accessories as required for complete installation as instructed by the engineer in charge.Vertical run- Down conductor

350

-

-

... More
od14790/2023_2024 : Supply, installation, and testing of 3-meter air terminal with accessories, providing and fixing air terminals as per IEC - 62305 part-3<br>16mm rod tapered to 10 mm aluminium rod: Meets the technical specification according to DIN EN 50164 - 2 (VDE 0815 part 202). Meets<br>the requirement of VDE0185/305 (IEC 62305) 101 VL 4000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind<br>load. The system consists of Fang Fix with a base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket,<br>lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and<br>easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked, including all accessories as required for<br>complete installation as instructed by the engineer in charge.

3

-

-

... More
od14791/2023_2024 : Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of the hexagonal plate.

10

-

-

... More
od14792/2023_2024 : Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required.

10

-

-

... More
od14793/2023_2024 : Supply and lay hot dip Galvanised Steel Flat having 70 microns zinc 30X3 mm thick from the earth electrode directly in the ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding including cross connectors and all accessories asrequired for complete installation as instructed by the engineer in charge.

250

-

-

... More
od14794/2023_2024 : Supply and Fixing Equipotential bonding rail for Lightning Arrestor applications (Test Joint). Equipotential bonding rail for equipotential bonding according to DIN VDE 0100-410/540 and lightning protection equipotential bonding according to DIN VDE 0185-305. Base plate and cover hood from polystyrene. Colour: Black, UV resistant. It can be used outdoors also. Screw and crossbar made of VA. Capable of carrying lightning current 100KA (10/350). Connection options: 7 x single or multi-core conductors to 25mm square or fine core conductors to 16mm square. 1 x round cable Rd 8-10. 1 x flat strip to FL 30 or round cable RD 8-10 including corrosion tapes and all accessories as required for complete installation as instructed by the engineer in charge.

12

-

-

... More
od14795/2023_2024 : Supply and fixing of expansion piece with connector: For equalising temperature-related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanized. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) and all accesories as required for complete installation

30

-

-

... More
od14796/2023_2024 : Supply and fixing of cross connector / T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanized iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts and all accessories as required for complete installation

40

-

-

... More
od14797/2023_2024 : Supply and installation of 8mm solid aluminium round conductor: For TERRACE APPLICATION Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq. mm cross-sectional area. Stainless steel base with Polyamide Conductor holder top: Adjustable width from 185-260mm. Infinitely adjustable conductor holder. Fast installation using wing screw. Bottom section with 8.5mm<br>diameter slot With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistance from -35 to +90 degrees Celsius were tested. Conductor holder @ 1-meter distance<br>

160

-

-

... More
EPABX

-

-

-

... More
od15642/2023_2024 : Surge Protection Device For EPABX: Supply, Installation, Testing, and commissioning of SPD with enclosure, the surge protection device shall be suitable to protect telephone lines designed to withstand both lightning current and switching surges. Technology: GD tube, Nominal Voltage: 180 V, Pulsed Current (10/350 µs ) Iimp: 1 KA, Nominal Discharge Current (8/20 µs )/phase In 5KA, Maximum discharge current: 10 KA, Voltage Protection Level(sym)<700V, Response time<1n sec

1

-

-

... More
od15644/2023_2024 : 2 Pair Cable - Supplying and drawing of 2 pair telephone cable consisting of 0.5 mm dia FR, PVC Compound annealed copper conductor, unarmored telephone cable in surface / recessed medium class FRS PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by an engineer in charge/consultant and making good all damages made for installation.

2000

-

-

... More
od15650/2023_2024 : Cable - Supplying and laying of the following pair of armored telephone cables through wall/tray with all accessories as required for complete installation and as instructed by an engineer in charge/consultant and making good all damages made for installation. 20 Pair Telephone Cable

40

-

-

... More
od15651/2023_2024 : Information Outlet RJ 11 - Supply, fixing, testing, and commissioning of RJ11 Information Outlets (Keystone) with shuttered Faceplate, single port, white, jack, suitable PVC / GI Modular Box, etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

90

-

-

... More
od15652/2023_2024 : Cable - Supplying and laying of the following pair armored telephone cable through wall/tray with all accessories as required for complete installation and as instructed by an engineer in charge/consultant and making good all damages made for installation. 10 Pair Telephone Cable

200

-

-

... More
od15653/2023_2024 : krone Box - Supply, erection, testing, and commissioning of the following pair krone with Box including mounting frame, enclosure of ISI grade with a lockable front cover with all accessories required for complete installation in the wall as directed by the Engineer in charge.20 Pair

1

-

-

... More
od15654/2023_2024 : krone Box - Supply, erection, testing, and commissioning of the following pair krone with Box including mounting frame, enclosure of ISI grade with a lockable front cover with all accessories required for complete installation in the wall as directed by the Engineer in charge.10 Pair

8

-

-

... More
od15655/2023_2024 : Supply, Installation, Testing, and Commissioning of "PBX with 90 Analog extensions expandable up to 150 with a maximum of 10 concurrent calls, 1 PRI interface, Failover Function, Web Interface, Call Dashboard, DISA, IVR, Call Hunt, etc. including two numbers master console phone & short key / Direct Station Selection (DSS) Console Built-In Auto Answer<br>, TDM/IP Coverage, ISDN Compatibility, Voice Mail Integration, Paging Announcement, Programmable Function Keys", Call Waiting

1

-

-

... More
od15656/2023_2024 : Supply, installation, testing, and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge.

90

-

-

... More
CC TV

-

-

-

... More
od15781/2023_2024 : Camera for Lift - Dome - Supply, Installation, testing, and commissioning of IP based 2.8 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in the false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

3

-

-

... More
od15782/2023_2024 : Camera for General Area - Dome - Supply, Installation, testing, and commissioning of IP based 3.6 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in the false ceiling as required for complete installation as directed by Engineer in charge.

10

-

-

... More
od15783/2023_2024 : Camera for Corridor - Dome - Supply, Installation, testing, and commissioning of IP based 2.8/3.6 mm to 9/12 mm varifocal lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in the false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

7

-

-

... More
od15784/2023_2024 : Camera - Bullet - Supply, Installation, testing, and commissioning of Varifocal Bullet Camera with 2 MP, H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm, 20 to 30 meters IR range, IP 66 with all connectors and necessary accessories for mounting in false ceiling / True Ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

5

-

-

... More
od15785/2023_2024 : Network Video Recorder with Storage: Supply, installation, testing and commissioning of 32 Channel Network Video Recorder with a Recording Storage space server for 30 days, Supports 32 channels 720 P resolution video recording at real time, NVR ONVIF supporting, Recording resolution of Max 4 MP, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording, with all accessories required for complete installation and directed by an engineer in charge. (Consider the sufficient HDDs for 720p @ 20 FPS for 30 days of continuous recording for all channels). Storage calculation details shall be submitted.

1

-

-

... More
od15786/2023_2024 : LED Display - Supply, installation, testing, and commissioning of 43-inch full HD LED display for video wall arrangement for 24 x 7 Setup including necessary connection, HDMI cable, rating tray, etc. as required for complete installation with all accessories as required and directed by an engineer in charge.

1

-

-

... More
od15787/2023_2024 : CAT6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG, surface / recessed medium class PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by an engineer in charge/consultant and making good all damages made for installation.

800

-

-

... More
od15788/2023_2024 : Supply, installation, testing, and commissioning of a workstation with Intel I5 latest generation processor or above, 16 GB ram and, 240 GB SSD, 1 TB HDD with software for CCTV integration

1

-

-

... More
STREET LIGHT BUS PILLER

-

-

-

... More
od29061/2023_2024 : Fabrication, supply, conveyance, installation testing and commissioning floor mounting, dust and vermin proof, cubicle type LV panel board (For Street Light) Out Door Type -IP65 comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using 1.6 mm CRCA sheet as per approved design and requirement for frame, with front access facility, compartments and earthlings the doors using braided copper conductor the board should be powder coating the assembly after subjecting to 7 tank process as required. shall not be used for the fabrication of panel assembly. The panel Board should be fitted on the base frame mounting with stand for panel board using angle iron including cutting, welding, drilling holes, painting two coats of synthetic enamel paint over a coat of zinc chromate paint bolting the frame to the panel and to the furnished floor using required bolts and nuts making good the damages colour washing and fixing the following switch gears etc as required suitable for operation on single phase and neutral,230V,5O HZ AC System with busbars extendable on both sides, including all the necessary internal wiring, suitable spreader, Panel Locking Facility: Provision of Door locking by Padlock and Panel lock etc. panel shall be with following switchgears, accessories etc. complete as required as per the drawing specification. incomer 40A FP , MCCB with adjustable thermal magnetic release with OL SC protection ,Surge protection device type 3Nos OUTGOINGS Timer clock with 25A FP contactors having an astronomical 365 day Timer clock SP RCCB+MCB 60mA - 1 Nos,including RCC pedestal of suitable size as per drawing of manufacturer for mounting including excavation, providing CC Foundation 1:2:4 work, metal frame work for fixing Street light flour mounted panel, plastering, coping and finishing the surface, installation of Street light panel on concrete pedestal etc. complete

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.