Kerala State Housing Board Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Summary
Aardram Mission Opd Transformation In Kozhikode Medical College Renovation Of Op Units In Nmch Block General Medicine And Psychiatry
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_KSHB_410560_1Bid Award Id
ViewTender No
EE/KKD/4/2020-2021-RTender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In
cement mortar
15.89
-
-
... More
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal
of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
0.81
-
-
... More
Dismantling the existing damaged wash basin as directed by the deparmental officers at site
6
-
-
... More
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50
metres lead:Of area 3 sq. metes and below
1
-
-
... More
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled
Tegular) Edge Tiles With Armstrong 15mmExposed GRID. brThe tiles should have Humidity
Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/mK, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x
16mm , suitable for Green Building application, with Recycled content of 32%. brThe tile shall be laid
on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal
in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2
& minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends &
“birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90
grams per M2 and need to be installed with Suspension system of Armstrong make. . brThe Tile &
Grid system used together should carry a 30 year warranty. brINSTALLATION:To comprise main
runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension
system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system
at the end of each main runner should not be greater than 450mm from the adjacent wall. brFlush
fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x
600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module
to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross
tees.brPerimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm
maximum centres.brInstallation to be carried out by Armstrong Trained Installation team & Installation
should be carried out as per Armstrong recommended procedure.brARMSTRONG SUSPENSION
SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6
Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a
Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length.,
thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
188.4
-
-
... More
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including
fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of
30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition with
the help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of
size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling
angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion
fasteners. Ceiling section of 0.55mm thickness having knurled web ofbr51.5mm and two flanges of
26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip
and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc
ultranewbr12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542-
1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm
centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable
attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush look
which includes filling and finishing the tapered and square edges of the board with jointing compound,
Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include
with all material shifting with all lead and lifts, masking for fixturesbr& frames, cutting light & AC cut
outs & temporary stand & scaffolding where ever required as per instruction by architect.
154.57
-
-
... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the
surface even and smooth complete.
154.57
-
-
... More
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified
by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved
make, in all colours and shades, including grouting the joints with white cement and matching pigments
etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer
modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.br
196.35
-
-
... More
Providing floor finish with anti-skid ceramic tiles best quality (exact shade to be got approved by the
architect) of size 300mmx300mm or nearest size for the toilets rooms , passage etc..laying in cement
mortar 1:4 12mm thick and closing the joints with white cement slurry mixed with approved matching
pigment including cost and conveyance of all materials to site, labour charges for laying and finishing tothe required level and slope etc. complete for all floors. br
3.13
-
-
... More
Providing and fixing I st quality ceramic glazed wall tiles of size 45x30 cms conforming to IS : 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with pigment of matching shade complete.
54.48
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
272.74
-
-
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new work
272.74
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two
or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of
approved brand and manufacture
91.56
-
-
... More
Mirror polishing on marble work/ granite work/stone work where ever required to give high gloss finish
complete.
104.72
-
-
... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall
etc. 25 mm pipe 12 kgf/cm2
30
-
-
... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall
etc. 50 mm pipe 6 kgf/cm2
30
-
-
... More
Supplying and fitting Automatic door closer for aluminium door including labour charges for fitting
conveyance etc completebr
0
2
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste
of standard pattern, including painting of fittings and brackets, cutting and making good the walls
wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm
C P. brass pillar taps with elbow operated levers ISI marked
10
-
-
... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the
floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.)
126.95
-
-
... More
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform,
vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps
etc. including moulding, rubbing and polishing of cut edges etc. complete
9
-
-
... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and
weighing not less than 690 gms.15 mm nominal boreer coating 50 micron)
5
-
-
... More
Supplying and fixing 15 mm CP angle cock
10
-
-
... More
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm
with concealed fittings arrangements, weighing not less than 106 gms.
11
-
-
... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws
with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length
of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms2
11
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium
(minimum thickness of powder coating 50 micron)
229.16
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making
provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket
required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder
coating 50 micron)
434.54
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0
mm thickness
56.65
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50
mm thickness
1.05
-
-
... More
Providing and fixing Aluminium grill work includind cost and conveyance of labour charges and cost of
channel fixing etc complete.br
10.02
-
-
... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood
particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows
shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural
drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination
on both sides
3.15
-
-
... More
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and
plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)s
0.21
-
-
... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
9.1
-
-
... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement
concrete for reinforced cement concrete work, using cement content as per approved design mix,
including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing
and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,
retard setting of concrete, improve workability without impairing strength and durability as per direction of
Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less
cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor
V level
0.39
-
-
... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
90
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,
landings, balconies and access platform
4.55
-
-
... More
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine
cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in
road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4
coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch
ups etc. complete as per direction of Engineer-in-charge.Area less than 0.50 sqm.
6.15
-
-
... More
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing
to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite
work
12.7
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST/KOEMMERING OR similar type upvc fixed partition wall using steel frames
of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm
plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer inchargebr
151.35
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST /KOEMMERLINGOR similar type upvc door using frames of
size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain /
frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction
stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge
NMCHbr
30.24
-
-
... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical
means, including loading, transporting, unloading to approved municipal dumping ground or as approved
by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
5
-
-
... More
Charges for loading ,transporting ,unloading to the dismantled serviceable materials such as anodised
aluminium doors and partition walls having particle board and glass etc to the PWD store shed which is
about 500mts apart as directed by the engineer in charge
5
-
-
... More
PSYCHIATRY
-
-
-
... More
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including
disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as
directed by Engineer - in-Charge
37.2
-
-
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres
lead.For thickness of tiles 10 mm to 25 mm
162.12
-
-
... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In
cement mortar
10.42
-
-
... More
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal
of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
1.44
-
-
... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal
of rubbish to the dumping ground within 50 metres lead.
54.72
-
-
... More
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled
Tegular) Edge Tiles With Armstrong 15mmExposed GRID. brThe tiles should have Humidity
Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m
K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x
16mm , suitable for Green Building application, with Recycled content of 32%. brThe tile shall be laid
on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal
in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2
& minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends &
“birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90
grams per M2 and need to be installed with Suspension system of Armstrong make. . brThe Tile &
Grid system used together should carry a 30 year warranty. brINSTALLATION:To comprise main
runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension
system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system
at the end of each main runner should not be greater than 450mm from the adjacent wall. brFlush
fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x
600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module
to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross
tees.brPerimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm
maximum centres.brInstallation to be carried out by Armstrong Trained Installation team & Installation
should be carried out as per Armstrong recommended procedure.brARMSTRONG SUSPENSION
SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6
Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a
Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length.,
thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
108.8
-
-
... More
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including
fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of
30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition withthe help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of
size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling
angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion
fasteners. Ceiling section of 0.55mm thickness having knurled web ofbr51.5mm and two flanges of
26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip
and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc
ultranewbr12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542-
1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm
centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable
attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush look
which includes filling and finishing the tapered and square edges of the board with jointing compound,
Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include
with all material shifting with all lead and lifts, masking for fixturesbr& frames, cutting light & AC cut
outs & temporary stand & scaffolding where ever required as per instruction by architect.
87.08
-
-
... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the
surface even and smooth complete.
87.81
-
-
... More
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified
by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved
make, in all colours and shades, including grouting the joints with white cement and matching pigments
etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer
modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.br
107.2
-
-
... More
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with pigment of matching shade complete.
46.53
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
227.63
-
-
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Twoor more coats on new work
227.63
-
-
... More
Providing & Fixing of Armstrong Mineral Fibre Acoustical SFinishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two
or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of
approved brand and manufacture
37.74
-
-
... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall
etc. 25 mm pipe 12 kgf/cm2
30
-
-
... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as
per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the walletc. 50 mm pipe 6 kgf/cm2
30
-
-
... More
Dismantling the existing damaged wash basin as directed by the deparmental officers at site
3
-
-
... More
Supplying and fitting Automatic door closer for aluminium door including labour charges for fitting
conveyance etc completebr
1
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste
of standard pattern, including painting of fittings and brackets, cutting and making good the walls
wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm
C P. brass pillar taps with elbow operated levers ISI marked
7
-
-
... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of thefloor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.)
177.73
-
-
... More
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform,
vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps
etc. including moulding, rubbing and polishing of cut edges etc. complete.
7
-
-
... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and
weighing not less than 690 gms.15 mm nominal bore
7
-
-
... More
Supplying and fixing 15 mm CP angle cock
7
-
-
... More
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm
with concealed fittings arrangements, weighing not less than 106 gms.
8
-
-
... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws
with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length
of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
8
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium(minimum thickness of powder coating 50 micron)
107.35
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making
provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket
required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder
coating 50 micron)r
243.45
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0
mm thickness
30.84
-
-
... More
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine
cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in
road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4
coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch
ups etc. complete as per direction of Engineer-in-charge.Area less than 0.50 sqm
3.15
-
-
... More
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing
to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite
work
18.9
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST/KOEMMERLING OR similar type upvc fixed partition wall using steel frames
of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm
plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer inchargebr
84.02
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST /KOEMMERLING OR similar type upvc door using frames of
size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain /
frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction
stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge
NMCHbr
20.16
-
-
... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical
means, including loading, transporting, unloading to approved municipal dumping ground or as approved
by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
33.18
-
-
... More
Charges for loading ,transporting ,unloading to the dismantled serviceable materials such as anodised
aluminium doors and partition walls having particle board and glass etc to the PWD store shed which is
about 500mts apart as directed by the engineer in charge
5
-
-
... More
MODIFICATION OF EXISTING STORE ROOM AS CONSULTING ROOM OF PHYCHIATRY
-
-
-
... More
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled
Tegular) Edge Tiles With Armstrong 15mmExposed GRID. brThe tiles should have Humidity
Resistance (RH) of 99%, NRC 0.5, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m
K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x
16mm , suitable for Green Building application, with Recycled content of 32%. brThe tile shall be laid
on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal
in white/black colour and with a web height of 38mm and a load carrying capacity of minimum 14 Kgs/M2
& minimum pull out strength of 100 Kgs.. Silhouette, Main Runners & Cross Tees to have mitred ends &
“birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90
grams per M2 and need to be installed with Suspension system of Armstrong make. . brThe Tile &
Grid system used together should carry a 30 year warranty. brINSTALLATION:To comprise main
runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension
system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system
at the end of each main runner should not be greater than 450mm from the adjacent wall. brFlush
fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x
600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module
to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross
tees.brPerimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm
maximum centres.brInstallation to be carried out by Armstrong Trained Installation team & Installation
should be carried out as per Armstrong recommended procedure.brARMSTRONG SUSPENSION
SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of M6
Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a
Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm of 1.8 m length.,
thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips
26.72
-
-
... More
Providing & fixing suspended ceiling in flat, curved or other shapes as indicated in the drawing including
fixing of G I. perimeter channels of size 0.55mm thick having one flange of 20mm and another flange of
30mm and web of 27mm along with perimeter of ceiling, screw fixed to be onto brick wall / partition with
the help of nylon sleeves and screws, at 610mm centers. Then suspending G I. intermediate channels of
size 45mm, 0.9mm thick with two flanges of 15mm each from the soffit at 1220mm centers with ceiling
angle of width of 25mm X 10mm X 0.55mm thick fixed to soffit with Gig. cleat and steel expansion
fasteners. Ceiling section of 0.55mm thickness having knurled web ofbr51.5mm and two flanges of
26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip
and indirection perpendicular to the intermediate channel at 457mm centers. all sections are gyproc
ultranewbr12.5 mm tapered edge Standard Gypsum board (confirming to IS: 2095- 1982 & 2542-
1981)gyproc or equivelant is then screw fixed to ceiling section with 25mm drywall screws at 230mm
centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable
attachment. Finally the standard gypsum boards are to be jointed and finished so as to have a flush lookwhich includes filling and finishing the tapered and square edges of the board with jointing compound,
Joint paper tape. Thecolour, shade and texture should be approved by Architect. Rate shall be include
with all material shifting with all lead and lifts, masking for fixturesbr& frames, cutting light & AC cut
outs & temporary stand & scaffolding where ever required as per instruction by architect.
16.17
-
-
... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the
surface even and smooth complete.
16.17
-
-
... More
11.41.2, 11.42, 11.43: Providing and laying vitrified floor tiles in different sizes (thickness to be specified
by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved
make, in all colours and shades, including grouting the joints with white cement and matching pigments
etc., complete.- Size of Tile 600x600 mm Ceramic/ Vitrified floor tiles with cement based high polymer
modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 mm thickness.br
47.84
-
-
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres
lead.For thickness of tiles 10 mm to 25 mm
6.36
-
-
... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and
disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In
cement mortar
0.22
-
-
... More
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal
of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
0.3
-
-
... More
Providing floor finish with anti-skid ceramic tiles best quality (exact shade to be got approved by the
architect) of size 300mmx300mm or nearest size for the toilets rooms , passage etc..laying in cement
mortar 1:4 12mm thick and closing the joints with white cement slurry mixed with approved matching
pigment including cost and conveyance of all materials to site, labour charges for laying and finishing to
the required level and slope etc. complete for all floors. br
2.64
-
-
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall
surface:Water thinnable cement primer
152.54
-
-
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new wo
152.54
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two
or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of
approved brand and manufacture
6.84
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per
manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade.
Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of
approved brand and manufacture
6.9
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST KOEMMERLING OR similar type upvc fixed partition wall using steel frames
of size60x40mm,upvc frame of size 60x57 ,1.5mm thick steel reinforcement inside upvc frame ,5mm
plain / frosted glass or upvc panel which ever is proposed by engineer in charge including ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer inchargebr
30.54
-
-
... More
Supplying and fitting LESSO EITI /ALUPLAST/ KOEMMERLING OR similar type upvc door using frames of
size112x60mm,steel frame work 60x50mm,2mm thick steel reinforcement inside upvc frame ,5mm plain /
frosted glass or upvc panel which ever is proposed by engineer in charge including hinges,friction
stays,screws,silicon sealant,single point lock/dead lock (godrej),handle,pedal,automatic door closer(godrej) ,making
charges ,conveyace charges,installation cgharges etc complete as directed by the engineer incharge
NMCHbr
4.2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements