Kerala State Housing Board Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 14,320Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Construction of NGO quarters highschool building electrical works
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_KSHB_204746_1Bid Award Id
ViewTender No
EE/KKD/02/2018-19Tender Authority
Kerala State Housing Board ViewPurchaser Address
-Website
http://http://www.kshb.kerala.gov.in/kshb/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
52
-
483
Single control light point without ceiling rose
6
-
823
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
-
-
-
4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) for lift
1
-
7739
12 way single phase double cover (IP 42/43)
3
-
1899
6 way (8+18) - three phase double cover (IP 42/43)
1
-
4039
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
-
-
-
63 A four pole mini break isolator
2
-
752
6-32A( C curve)
30
-
219
40 A, 4 pole, 30 mA RCCB
1
-
2780
40 A double pole mini break isolator
3
-
356
25 A, 2 pole, 30 mA RCCB
3
-
2023
40 A, 10 kA, DP MCB (Ccurve)
3
-
900
Supply, conveyance installation testing and commissioning of 230V, 50Hz, 1800Lumen, 0.8pf, 15% THD, 2.5KV Lighting surge protection type 18W 1200mm LED pre-wired light fittings complete with all accessories, directly on wall or ceiling and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire etc as required.
54
-
868
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200 mm sweep - 5 star rated.
73
-
1853
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
2
-
3917
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required. 300 x 300 x 6 mm cast iron gully trap with covering.300 x 300 x 6 mm cast iron gully trap with covering.
2
-
267
Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip.
0.15
-
165
Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 x 3 mm GI strip.
3
-
73
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.
-
-
-
3.15 mm copper conductor (10 SWG)
120
-
62
2.00 mm copper conductor (14 SWG)
10
-
26
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
-
-
-
3.15/2.65 mm (12 SWG)
16
-
19
2.65 mm (12 SWG)
10
-
19
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
-
-
-
25 x 6 mm GI bolt & nut
10
-
10.7
S & F following HRC fuses
-
-
-
2 A-16A clip-on offset tag fuse link of size f1
3
-
66
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 600x300x214mm.
1
-
6681
Supply and fixing the following accessories in the existing meter board and giving connections etc.
-
-
-
20 A fuse holder for BS type blade fuses.
3
-
122
32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
1
-
105
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 2 core 6 sq mm.
15
-
147
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.
-
-
-
2 core 6 sq mm.
30
-
138
4 core 10 sq mm.
10
-
171
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
-
-
-
2 core 6 sq mm with factory made clamp.
40
-
157
4 core 10 sq mm with factory made clamp
10
-
197
Supplying siemens / tropodur type nickel plated Double compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. 4 sq mm.
6
-
221
Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip.
6
-
18
S & F switch disconnector fuse unit complete with handle assembly, door inter lock and padlocking arrangement of the following ratings: 32 A, AC 23 A, TPN SDF for DIN fuse.
1
-
1567
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting of the following types complete with all accessories and lamps etc. in the existing GI pipe and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. 16 to 20 w LED street light fittings.
2
-
2564
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. 20 mm dia light gauge .
2
-
510.16
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
-
-
-
2.50 sq mm 3 run for PP
220
-
107
1.50 sq mm 3 run for street light main, computor plug
200
-
77
1.50 sq mm 4 run
50
-
94
1.50 sq mm 5 run
50
-
110
1.50 sq mm 6 run
50
-
126
Supply and fixing angle / straight skirt type, bakelite batten holder without shade and giving connection etc as required.
6
-
60
Supply and fixing 8-10W LED Bulb.
6
-
150
Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 225 mm, single phase, light duty exhaust fan in metal frame.
3
-
1712
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required ( Group B)
-
-
-
3 module metal box in recess
11
-
180
1/2 module metal box in recess
14
-
165
6 module metal box in recess
4
-
198
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. (RoHS)
-
-
-
3 module white/ off-white
11
-
116
1/2 module white/ off-white
14
-
101
6 module white/ off-white
4
-
152
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)
-
-
-
6 A SP 1 way switch for street light
10
-
119
16 A SP 1 way switch for Lab
11
-
161
6/16 A socket
11
-
223
3 Plate ceiling rose
2
-
48
6 A Universal socket
8
-
147
16A DP switch master control for calss rooms
12
-
250
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
3
-
274
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements